Overlooked Area :
Colloidal Silica in Power Plant Water Chemistry
11/07/2015

In power plant boilers most The surface water contains over the article also empha-
critical parameter of water high amount of silica and sizes the importance of
chemistry is Silica in specifically colloidal silica accurate water chemistry
steam. which is the main culprit analysis and common is-
for turbine deposition. sues faced by industries
Steam purity is highly
and how to overcome those
needed and is critical for This article highlights the
issues.
consistent power genera- importance of water chem-
tion. It is observed that istry, Silica chemistry and
surface water is being used how to control or prevent
by many power plant in- silica deposition in power
dustries as makeup water. boiler and turbine. More-

Need For Boiler Water Treatment at Power


Plant
ALTRET INDUSTRIES PRIVATE LIMITED

Water is the essential me- Therefore the aim of the water and routed the boiler
dium for steam generation. boiler water treatment is from where it came.
BONDAN INTERNAL TECHNICAL MAGAZINE

Conditioning it properly
1) To prevent the forma- About 500 g of deposits
can increase the efficiency
of boiler and as well as tion of scales and deposits distributed more or less
extend the boilers life . on heating surface evenly all over the
Treating boiler water also 2) To prevent corrosion blading section can
insures safe and reliable in the boiler and steam bring down turbine
operation: without proper system. efficiency by 1%.
treatment, severe problems
can develop, some so se- 3) To maintain high level
vere that boiler itself can be of steam purity.
destroyed. The water which directly
Boiler water problem gen- enters a boiler is referred to
erally falls into classes: as Boiler feed water.
deposit related and corro- Boiler feed water may be
sion related. Because the made of Make up water
two often interact, it is very and of one or more sources
common to find a boiler of Condensate return. Make
experiencing both simulta- up water is the original
neously. There are many water which enters the
instances where deposit industrial process as well
causes corrosion and cor- water or surface water and
rosion causes deposits. is further purified for spe-
cific use in boilers . This
The other problem is of should be viewed as new
steam purity. The live water which enters the
steam is contacted with boiler cycle. Return con-
turbine blade at specific densate is water which is
temperature and pressure passed through the boiler,
hence pure quality of steam evaporated to steam, served
is very much important to some purpose throughout
prevent turbine trouble free the system and then been
operation. condensed back to liquid
Chemistry of Silica
Silica (SiO2) exists in water in equilib- you really are at really low cycles). Be- regenerated. In fact, if one uses a conven-
rium with the bi silicate (HSiO3-) ion as a sides, accuracy may suffer at << 1 ppm tional definition of colloidal silica as that
very weak acid. In the ionic form, silica which measures greater than 50 ang-
silica in feed water sample.
can be removed by strong base anion stroms, even ultra filtration with a mo-
exchange resins operated in the hydrox- The measurement of total silica is gener- lecular-weight cutoff (MWCO) of
ide cycle. Since the two forms exist in ally considered an off-line procedure; in
100,000 daltons is effective at removing
equilibrium, silica can be almost com- most cases, a water sample is transported
colloidal silica.
pletely removed from solution. When to a lab for analysis.
present as a single unit of silica, in equi- Silica is generally found in water supplies
In monsoon season the colloidal silica is
librium with bi silicate, the compound is in three different forms: reactive, colloi-
higher compare to other season. Colloidal
termed reactive silica. dal and suspended particles (e.g. sand),
silica can be minimizing up to some ex- with the reactive being that portion of the
Silica can also exist as a polymer, often tent with clarifier, Clarifier cannot elimi-
total dissolved silica that is readily re-
referred to as colloidal silica. These nate silica @100%. . The success of co-
acted in the standard molybdate colori-
long chains of individual silica units agulation process is depends on adequate
metric test, and the colloidal being that
exhibit virtually no charged ionic char- contact of colloidal particle & coagulant.
which is not.
acter, and cannot be removed by the Organic matters associated with colloidal
ionic process of ion exchange. particle should be oxidized with any oxi- Total silica should be the sum of the
dizer before coagulation process start for reactive silica and colloidal silica. But
successfully remove colloidal compound total silica may not be expressed that
Silica Boiler Feed Water: through coagulation process. Coagulation way and colloidal silica may not show
process is only effective under ideal con- up on such tests.
Silica is a problem for high pressure boil- dition and up to 80-90 % non reactive
ers. It exhibits enough volatility that high Colloidal silica is insoluble and is some-
silica can be minimize with this physical
pressure boilers will have silica carry thing that can be filtered out with a
process.
over to the vapor partition. When the whatman filter. Reactive silica is Dis-
steam pressure is reduced in the tur- Colloidal silica is typically found in sur- solved. Colloidal silica is difficult to
bines, the silica will precipitate on the face waters and has created problems for detect in low (ppb) concentrations, and
blades as a glassy deposit which re- water treatment because of its stability as not many labs are capable of providing
duces efficiency. Both types of silica, an un-ionized compound, making it diffi- analyses.
colloidal and reactive, can cause this cult to remove using ion exchange proc-
problem as colloidal silica will break esses.
down and volatilize under high tempera-
Silica is at the lower end of
ture and pressure.
selectivity for anion resins, Main Impurities Found in turbine
Silica is tricky because colloidal silica creating a scenario where deposit are
may not show up in your feed water silica breakthrough is one
silica test (only reactive SiO2 will, unless of the first to occur. As a Magnetite Corrosion Product
you do a more involved total silica test), result, silica can be effec- Sodium Chloride
yet the colloidal silica will break down to tively removed only if the
reactive silica in the hot boiler. So this ion exchange resins are Silica
may give you erroneously high results completely and properly
(dont understand your numbers, unless

Few Recommended Actions or Guidelines to Prevent


Silica Deposition & to Maintain Correct Water
Chemistry Parameters

As we all must aware that prevention is better than cured. Here are some guidelines to prevent Power plant turbine & boiler free from
Silica deposition and maintain other water chemistry parameters within specified limits. Obviously preventive action & its cost is rela-
tively low in term of power generation or plant availability.

Page 2 Colloidal Silica in Power Plant Water Chemistry


Installation
As describe earlier clarifier doesnt re- can be cost-effectively and efficiently from the selective layer and prevents
move colloidal silicate effectively same used to eliminate colloidal silica and in fouling of the membrane. Ultra filtration
way Microfiltration, s sand filtration, that way prevent damage of turbine is can be effectively remove non reactive,
cartridge filtration, and diatomaceous polymeric silica in addition with remov-
blades.
earth filtration would not be effective in ing other suspended impurities. Ultra
removing colloidal silica. Moreover one Ultrafiltration (UF) is a method used to
filtration can be installed at the outlet of
has to keep strong complex monitor, add- separate extremely small particles and
the mixed bad unit.
ing flocculent or other chemicals, de- dissolved molecules based on their size.
pending on man power if decide to con- This process is achieved through the use
trol colloidal silica by conventional of membranes. The morphology of a UF
mechanism. These type practices are also membrane is critical to its performance in
require experiences. There are many limi- any type of device. The asymmetric
tations of coagulation process also. structure of the UF membrane causes
particles larger than the molecular weight
If Surface water is being used colloidal cutoff (MWCO) of the membrane to be
Silica may be culprit, Effective pre treat- retained on the surface while allowing
ment is installation of Ultra filtration. The smaller species to pass through the mem-
effective operation of Ultra filtration con- brane substructure. The membrane's sub-
trol colloidal silica. Ultra filtration system structure provides rapid transport away

Measurement & Monitoring

Generally in Industry contest theres an of water testing. The faulty or substan- Moreover, it is also experienced by au-
old saying that you cant control what dard testing may lead poor control on thor that pretreatment of source water is
you dont measure and there no exclu- water chemistry parameters inside the under control by process or manufactur-
sion to avoid silica in power generation boiler and ultimately lead deposition or ing departments and power plant is only
its crucial to keep it under tight control. corrosion in boilers and turbine. responsible feed water.
Effective monitoring through on time
Its also observed that lacking in coordi- Recently there was incident that clarifier
Silica measurements at regular intervals
nation between departments such as qual- to treat surface water was undergone for
is only solution. Silica should be measure
ity control & power plant may lead poor maintenance for 20 days managed by
at laboratory with proper devices by
control on water testing may lead prob- water treatment department and reported
qualified chemist. It should be measure
lem of deposition or corrosion. Sampling to process manufacturer and but power
up to 10 ppb level. In feed water and
is very importance in the case of control plant authorities were not informed for
source water before and after pretreat-
of water chemistry parameters or Silica the same.
ment Non reactive Silica can be measure
control. The role of staff that is responsi-
as described earlier. It would be advisable that power plant
ble to collect the water samples on right
authorities review pretreatment data of
Its generally observed Many Captive time and with right method in right sam-
water quality if headed by different de-
power plants or Co-gen Power plant dont ple collections pots is also very impor-
have separate laboratory which should be partment.
tant.
responsible to measure correct power To monitor Silica, online analyzer can be
In many power plants, because of long
plant water chemistry parameters or else installed at different location such make
distance between sample collection points
specific measurement instruments are not up, feed, boiler and steam in addition
and testing laboratory, the collected sam-
available in laboratory. Many times we with installation online conductivity
ple may be not representing actual condi-
had observed that chemists of Common TDS, D.O. analyzers.
tion. The responsibilities of sample col-
laboratory or quality control laboratory
ignore the criticalness of water chemistry lection are headache between internal There is a limitation of online silica ana-
parameters. Some time its also observed departments. lyzer such devises only measure dissolve
that because of lack of time, existing constitutes of water neither suspended or
To overcome such issues author recom-
work load, give priority to process mend specific water chemistry laboratory colloidal forms silica.

testing and gives less importance to water should be under control of power plant
head. Same way sample collection is
testing may lead the substandard quality
under control of power plant department.

Page 3 Colloidal Silica in Power Plant Water Chemistry


ALTRET Trouble Shooting & Monitoring
Below are the probable reasons for high frequency is also very important to main-
Silica in boiler water and steam. tain desire parameters.
ALTRET INDUSTRIES PRIVATE High Silica in MB water due to poor Water Treatment Chemicals qualities are
LIMITED 1 also play vital role for significantly dis-
operation of MB/ DM water
turb desire boiler & steam parameters.
High Silica in Condensate water due Technical or Industrial grade Trisodium
12/2881, ALTRET HOUSE, 2 to condenser in leakage and cooling phosphate (TSP) may become culprit.
SAIYEDPURA MAIN ROAD Instead of preventing scale may be dis-
SURAT-395003 tower water mixes.
turb water chemistry because of impuri-
Phone: 0261-2451807-808-809 Poor water quality usage in HP/ LP ties present in product. It is advisable use
Fax: 0261-2434517 3 dosing system for chemical dilution
E-mail: info@altret.com laboratory grade TSP from reliable
sources. Also it is recommended to
Poor quality of chemicals / chemicals
4 counter check purity of product at labora-
contains high silica.
tory before injecting to the boiler.
Presence of Colloidal Silica in feed
WE MATCH WITH YOUR 5 water / MB water. Same way other water treatment chemi-
SPECIFICATION cals purity should be always concern such
as pH booster/ alkalinity builder
If Mixed bad unit over run, or resins are
(Ammonia/ Morpholene / oxygen scaven-
fouled, may chances of Silica excursion
ger ( Hdyrazine hydrate/ DEHA/ MECO
through MB and may cause deposit in
etc) . and phosphate conditioning and
boiler. Same way minute leakages may
condensate corrosion preventive chemi-
cause adulteration condensate quality,
www.altret.com hence silica / high conductivity contains
water enter to boiler drum. The best way
cals ( Cyclohexyl Amine, DEA or other
volatile amine and their blends)
to counter check any leakages in conden- If power plant industries either use basic /
sate is that checks water parameters of generic chemicals or product from water
steam entering to condensers and conden- treatment chemicals manufacturer, speci-
sate water after condenser. fication and purity of each chemicals
should be counter check. Generally all
It was notice that in some places operator
Compiled By: standard manufacturers are providing
/ staff prepare chemical dozing solution
specification or COA along with every
Zakirahmed Atashbajiwala in raw water!! But natural raw water con-
tains high silicate & conductivity. The supply of products.
Vice President-Tech. & Mkt complete water treatment program may
disturb in such ignorance. Its advisable
Altret Industries Pvt Ltd to procure pure MB water very near to
info@altret.com HP & LP dozing system. The injection
rate, proper dilution and dozing

Role of Water Treatment Chemicals Supplier


There are many ways to approach the selection of a sound and effective internal boiler water treatment program. Above all, the best se-
lection can be made with a proper understanding of system design, capabilities, water chemistry and common sense. Present boiler water
technology provided by vendor should be efficient, cost-effective and reliable operative for industrial boiler systems. Selection of the
best internal treatment program is a function of many factors. However, the ability to control the program should be the first considera-
tion.
The water treatment supplier vendors provide chemicals along with services to maintain and control desire water chemistry parameters.
The vendor also arrange customer awareness program, arrange management review meeting to evaluate existing performance and inter-
act with plant people for scope of improvement.

Reference
1, ALTRET handbook for water treatment 2. Behavior of silica in ion exchange & other systems by peter Meyers/resin tech inc. 3. Power engineering July 2008. 4. An article-Steam turbine corrosion & deposit
problem & solution by Otakar Jonas & Lee Mechamer wellington 5. Water and Wastewater by Hammer and Hammer 6. The application of membrane technology - Lynn Cotterill Source: Water Quality Products
April 1996 7. RO water chemistry-01/23/01 Hydronautics 8.Meassuring & removing dissolved silica in ultra pure water- Johanes wibowo & farhang shadman-Arizona uni& David blackford- American fluid company.
9. Optimising power plant efficiency by measuring silica by Pierre guillou and Katrien Verhassel 10.collodial silica treatment & removal-ion exchange -water tech No 9 Aug 2009