Mineral Admixture Class N F c Chemical Requirements Silicon dioxide, aluminum oxide, Iron oxide (SiOz + Al203 + Fe203) rnin, % 70 70 50 Sulfur trioxide (GOs), max. % 40 5.0 5.0 Moisture content, max. 9% 3.0 20 30 Lose on ignition, max. % 10.0 60 60 Available alkalies as Na,O, max 9° 15 15 15 Physical Requirements Fineness, max. % retained on 25-mesh sieve a4 4 4 Portland Cement 7-day, min. % control se 7s 7s 28-day, min % of control oy 7s 7s Walter requirement, max. % of control 1s 108 108 ‘Autoclave expansion, soundness, max. 9% o8 a8 a8 ‘A. The use of Class F pozzolan with up to 12% loss on ignition may be approved by the user if either acceptable performance records or laboratory test results and made available. B. Applicable only when specifically required by the purchaser for mineral admixture to be used in concrete containing reactive aggregate and cement to meet a limitation af the alklai content C. Meeting the 7 or 28 day strenath activity index will indicate specification compliance.