Você está na página 1de 2

SDS-9000

AADvance Industrial Control System

FEATURES:

Choice of differing
fault tolerant topolo-
gies 1oo1D, 1oo2D
and 2oo3D
Flexible modular con-
struction using indi-
vidual modules to
build a system
Operates as a stand
alone system or part of
a large distributed
network
Easily transformed
Overview SIL2 or a SIL3 safety related con- from simplex non-
troller. safety system to a
The AADvance 9000 Series Con-
fault tolerant safety re-
troller is a new industrial safety con- All AADvance 9000 Series module
troller that is built from a range of lated system
configurations support the following
compact individual modules. Each degradation modes: Scalable I/O module
module has been developed to the expansion without
IEC 61508 standard and they pro- Simplex system interruption
vide a flexible and scalable safety 1-0
controller solution. Duplex (with fault detection) IEC 61508 certified
2-1-0 system
Because they are easy to assem- High availability TMR
ble, they offer you the flexibility to 3 - 2- 1- 0 Handles full range of
create a controller that can be used A typical AADvance 9000 Series IEC 61131 application
in a wide variety of applications: Safety Controller for a simplex ap- programming lan-
plication will have the following guages
Critical process control products:
One Processor Module and
Supports Black Chan-
Fire and gas protection sys- nel external communi-
tems Backplane
cations over Ethernet
Rotating machinery control I/O Modules and matched between peer control-
systems Termination Assemblies lers
I/O Backplanes with Inter-
Burner management Supports industry
Module Communication and
Boiler and furnace control Response Busses
standard protocols
such as Modbus Slave.
Distributed monitoring and IEC 61508 Certified Operating
control System Supports OPC when
You can also use the controller as a
using an OPC Portal
AADvance Safety Kernel
stand alone system or a system that
interfaces to a wider distributed A simplex I/O with a single proces-
network, e.g. other AADvance en- sor will meet the needs of a SIL2
abled controllers such as a Trusted requirement, while simplex I/O with
TMR installation. dual processors will meet the needs
of SIL3 de-energize to action re-
This built-in flexibility gives you the quirement. Extra modules can be
choice of system architectures. Us- added in a redundant configuration
ing the same type of modules you to increase fault tolerance, or to
can configure a controller that can satisfy a SIL3 Energize to Action
manage a simplex non-safety appli- requirement.
cation, or, just as easily, create a

Issue 01: Aug 2008


SDS-9000
AADvance Industrial Control System

Communications IEC 61508 certified operating


In redundant configurations Proces- The controller has two serial ports software and the AADvance
sor and I/O Modules can be re- and two Ethernet ports for each Safety Kernel and Target soft-
moved on-line without affecting the processor module. It supports Black ware.
system performance. When a proc- Channel communications and can
essor module is removed it will only TUV Validation and certifica-
transport safety related data across tion
affect the external communication external bearers which in them-
paths connected to that processor. selves do not have a safety re-
quirement. ICS Triplex Technology 2008
Termination Assemblies interface
the I/O modules with field connec- The AADvance data may be pass- ICS Triplex Technology Ltd.
tions; they provide simplex, dual, ing to a second controller or to intel- ICS House
and triple I/O configurations. This ligent field devices. Black Channel Hall Road,
offers you a wide choice of I/O con- communications will typically use an Maldon
figurations and an extremely flexible Ethernet LAN, which can use off- Essex CM9 4LA
I/O system connectivity. the-shelf components and provides
particularly cost-effective solution. +44 1621 854444
Software Fault Tolerant Design www.icstriplex.com
Each processor has an embedded Designed to the IEC 61508 Stan-
IEC 61508 certified operating sys- dard and certified by TUV, the
tem and the AADvance Safety Ker- AADvance controller has a SIL3
nel and Target software. The proc- fault tolerant performance rating.
essor will handle the full range of
IEC 61131 application programming To achieve this high fault tolerance
languages performance it supports:

Software, supporting industry stan- Synchronised dual and triple


dard protocols is also available for processing configurations
communication across a distributed Fault tolerant data exchange
network, such as: services
Modbus Slave
Secure black channel com-
OPC can be supported using munications
an OPC portal.
Dual and triple I/O module
configurations

Issue 01: Aug 2008