Você está na página 1de 1

A.

GENERAL :
1. ALL STRUCTURAL PLANS ,SPECIFICATIONS, AND SHOP TEMP. BAR & CONTINUOUS BAR
DRAWINGS, SHALL MEET ALL REQUIREMENTS SET BY THE
BEAM
NATIONAL BUILDING CODE, NATIONAL STRUCTURAL CODE 16MM DIA RSB MAIN
OF THE PHILS., AND THE LOCAL CODE OF THE CITY / CHB wall COLUMN COLUMN
MUNICIPALITY / DISTRICT OF THE SITE. 16MM DIA RSB MAIN BOTHWAYS PROVIDE
DOUBLE BARS ON ENDS
2. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY
TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR NOTED, APPROACH FIN FLR LINE
Rebar 12MM DIA RSB TEMP
MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL

TEMP. BAR & CONTINUOUS BAR

TEMP. BAR & CONTINUOUS BAR


CONDITIONS.
3. SHOP DRAWINGS WITH ERECTION AND PLACING
DIAGRAMS OF ALL STRUCTURAL STEELS, MISC. IRON,
PRE-CAST CONCRETE, ETC., SHALL BE SUBMITTED FOR THE
ENGINEER / DESIGNER'S APPROVAL BEFORE FABRICATION. 16MM DIA RSB MAIN
4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO R.C. BEAM
2"thk Gravel fill BOTHWAYS PROVIDE (VERIFY DETAIL)
PROVIDE ADEQUATE SHORING & BRACINGS OF THE DOUBLE BARS ON ENDS
STRUCTURE FOR ALL LOADS THAT MAYBE IMPOSED DURING Compacted soil
CONSTRUCTION. LANDING
16MM DIA RSB MAIN
B. CONCRETE :
1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM

BEAM

BEAM
WITH THE LATEST BUILDING CODE OF AMERICAN
CONCRETE INSTITUTE (ACI-318).
CHB TO SLAB-ON-GRADE DETAIL 12MM DIA RSB TEMP

2. ALL CONCRETE SHALL DEVELOP A MIN. COMPRESSIVE R.C. BEAM


(VERIFY DETAIL) COLUMN COLUMN
STRENGTH AT THE END OF TWENTY EIGHT (28) DAYS (MAX.
PERIOD): BEAM

LOCATION 28 DAYS MIXING FIN FLR LINE TEMP. BAR & CONTINUOUS BAR
STRENGTH PROPORTION
ALL CONCRETE 2,500 PSI CLASS B / 1 : 2 : 4 CHB wall 16MM DIA RSB MAIN 12MM DIA RSB TEMP
NOTE : EXTRA BARS ON
MEMBERS STAIR NOSING & ZIGZAG
Rebar BARS ALONG 'RUN & RISER'
3. IN GENERAL THE LATEST EDITION OF ACI-315, MANUAL ARE NOT REQUIRED. WALL FOOTING
OF STANDARD PRACTICE DETAILING REINFORCED (VERIFY DETAIL)
CONCRETE STRUCTURES SHALL BE ADHERED TO UNLESS 0.10M THK SCALE: 1 : 50 MTS
OTHEREWISE SHOWN OR NOTED. GRAVELFILL

C. REINFORCEMENT:
1. ALL REINFORCING BARS SHALL CONFORM TO ASTM 2"thk Gravel fill
A615 GRADE 33 FOR DIAMETER 16 AND SMALLER BARS AND
GRADE 40 FOR DIAMETER 20 AND LARGER BARS.
2. ALL ANCHOR BOLTS, DOWELS, AND OTHER INSERTS, Compacted soil
SHALL BE PROPERLY POSITIONED AND SECURED IN PLACE
PRIOR TO PLACING OF CONCRETE.
3. ALL INTERSECTING BARS SHALL BE SECURED USING A
NO.16 TIE WIRE.
4. SPLICES IN BEAMS, SPLICE HALF OF THE BARS AT 1/4
SLAB-ON-GRADE END DETAIL SCALE: NTS

OF THE SPAN OF THE BEAM FROM FACE OF SUPPORT, AND


SPLICE THE OTHER HALF AT 1/4 OF SPAN FROM THE
OPPOSITE SUPPORT.
5. SPLICES IN COLUMNS, SPLICE HALF OF THE BARS AT 1/2
OF THE COLUMN HEIGHT FROM THE BASE AND SPLICE THE
OTHER HALF AT 1/2 OF THE COLUMN HEIGHT OF THE
SUCCEEDING FLOOR.
6. SPLICES SHALL BE SECURELY WIRED TOGETHER AND
SHALL LAP OR EXTEND IN ACCORDANCE WITH TABLE 1
(TABLE OF LAP AND SPLICES AND ANCHORAGE LENGTH)
UNLESS OTHERWISE SHOWN ON DRAWINGS, SPLICES SHALL
BE STAGGERED WHENEVER POSSIBLE. Rebar
D. MASONRY:
1. ALL CONC. HOLLOW BLOCK (CHB) SHALL USE
NON-LOAD BEARING CHB UNLESS OTHERWISE SPECIFIED.
2. ALL PLASTER AND MORTAR MIXTURE SHALL USE CLASS
2"thk gravel fill
B/1:3 Compacted soil
3. PROVIDE LINTEL COLUMN FOR EVERY 3.0M DISTANCE.
PROVIDE LINTEL BEAM FOR EVERY 3.0M HEIGHT.
E. STRUCTURAL STEEL:
1. ALL STRUCTURAL STEEL MEMBERS SHALL CONFORM
SLAB-ON-GRADE
TO ASTM A36 (Fy = 248 MPA)
2. ALL CONNECTIONS SHALL BE FILLET WELD OR
DEPRESSION DETAIL 1
OTHERWISE SPECIFIED USING E60 WELDING ROD.
3. MIN. LENGTH OF FILLET WELD MAY NOT BE LESS THAN
4 TIMES THE NOMINAL LED SIZE OF THE WELD. MAXIMUM
SIZE OF FILLET WELD = 6MM. FOR THICKER MATERIALS IT
SHOULD NOT BE GREATER THAN THE MATERIAL LESS 2MM.
END RETURN SHOULD NOT BE LESS THAN TWICE THE
NOMINAL SIZE OF WELD.
SCALE: NTS
F. FOUNDATION:
1. THE ALLOWABLE FOUNDATION PRESSURE USED WAS
BASED ON AN ASSUMED VALUE OF 150 KN/SQM BASED ON
CHAPTER 7 TABLE NO.7-B OF THE NSCP.
2. THE LATERAL BEARING USED WAS BASED ON AN
ASSUMED VALUE OF 60 KN/SQM/M OF DEPTH BASED ON
CHAPTER 7 TABLE NO. 7-B OF THE NSCP.
3. THE LATERAL SLIDING USED WAS BASED ON AN
ASSUMED VALUE OF 0.35 BASED ON CHAPTER 7 TABLE NO. SCALE: NTS
7-B OF THE NSCP.
4. PROVIDE ADEQUATE SHORING & PROTECTION FOR
EXCAVATION OF EARTH.

DRAWN BY : APC
CIVIL ENGINEER: PROJECT TITLE OWNER SHEET CONTENTS REVISIONS SHEET NO.
DATE : 02-20-16
DESIGNED BY : STRUCTURAL NOTES
DATE : MASONRY DETAILS
CHECKED BY : APC STAIRWAY DETAILS
WALL OPENING DETAILS
DATE : TWO-WAY SLAB DETAILS
PTR. NO. : 5784897 PRC. NO. : 086681 APPROVED BY :
DATE : JAN. 16,2016 DATE : NOTED BY :
PLACE : LOPEZ, QUEZON T.I.N. : 222-552-996 DATE :
LOCATION : SAN JOSE ST., BRGY. TALOLONG, LOPEZ, QUEZON ADDRESS : BRGY. TALOLONG, LOPEZ, QUEZON