Você está na página 1de 149

A Wholistic Approach to HRSG

Inspections

Charles Turner, P.Eng.


Charles G. Turner & Associates Ltd.
Consulting Engineers

Presented at the
2014 Canadian HRSG Forum
October 21, 2014

Charles G. Turner & Associates Ltd.


Charles G. Turner and Associates Ltd.
(CGTA)

Consulting Engineers specializing in Power


& Utilities

Founded in 1973

Located in Toronto, Ontario, Canada

Charles G. Turner & Associates Ltd.


CGTA Areas of Expertise
Simple Cycle and Combined Cycle Power Plants
Thermal Power Stations (Coal, Gas & Oil Fired)
Cogeneration (Steam Turbines, Gas Turbines &
Reciprocating Engines)
Central Heating Plants (Steam Boilers, Thermal
Fluid Heaters & Vaporizers, Glycol & Hot Water,
Plant Auxiliaries, buried steam & HW distribution
piping)
Central Cooling Plants (Chilled Water,
Refrigerant, Steam Absorption & Ammonia, buried
chilled water distribution piping)

Charles G. Turner & Associates Ltd.


CGTA Areas of Expertise
Continued
Burners & Combustion (Natural Gas, Fuel Oil,
Liquid and Gaseous Process Fuels, Biomass)
Water Treatment Systems
Compressed Gas Plants (Air, Digester Gas, Landfill
Gas and Carbon Dioxide)
Industrial Plant Processes
Industrial HVAC
Cooling Tower Systems
Instrumentation & Controls (PLC & DCS)
Electrical Generation (High and Low Voltage)
Charles G. Turner & Associates Ltd.
Putting Wholistic into
HRSG Inspections
Wholistic refers to the approach and execution of
the HRSG inspection, where the HRSG is inspected
from an asset integrity and management approach.

The approach integrates the HRSG inspection and


boundary limits into the Companys long term
maintenance plan that includes;
Integrity Plans
SAMPs
Long Term Maintenance Plan

Charles G. Turner & Associates Ltd.


Aligning Inspection Deliverables within
the Asset Management Plans
What is a Corporate Asset Management Plan?
Defines the organizational goals and objectives of the
plant components.
Defines performance targets.
Provides future demand forecasts.
Specifies regulatory requirements.
Identifies site specific maintenance intervals, capital and
operating improvement projects.
Records equipment condition.
Provides a summary location for the performance
history and operating strategy to maintain performance
requirements.

Charles G. Turner & Associates Ltd.


HRSG Integrity Plans
HRSG Integrity Plans are developed to support
the Asset Management Plans:
Defines the life cycle wholistic view of the specific
equipment.
Incorporates Operations and Maintenance strategies.
Develops Risk Assessment including analysis and
consequences.
Defines Provincial and State compliance requirements.
Assurance of Insurance compliance requirements.
Provides a basis for the lessons learned.

Charles G. Turner & Associates Ltd.


Critical Pre-Inspection
Key Parameters
HRSG Superstructure Design
Bottom supported components
Top hung from casing superstructure

Waste Heat Source:


Gas Turbine - Size/Make/Model
Duct Firing Location and rating

Operating Parameters
Number of Pressure Levels
Pressure/Temperature
Operating Hours
Number of Cold Iron Starts, Cold/Warm/Hot Starts, Forced
Cooling Events, and EOHs.
Charles G. Turner & Associates Ltd.
Critical Pre-Inspection
Key Parameters Continued

High Temperature Materials


P91/T23

Hardened Low Temperature Regions for FAC

In-Cycle water treatment program


HP & IP Phosphate / LP SALP or FFLP?
Once Through requirements.
Cascading Blowdown.

Charles G. Turner & Associates Ltd.


Typical F Technology Triple
Pressure HRSG

Charles G. Turner & Associates Ltd.


Once Through Steam Generator

Charles G. Turner & Associates Ltd.


Enhanced Oil Recovery Once Through
Wet Steam Generator

Charles G. Turner & Associates Ltd.


External Casing Inspection

Charles G. Turner & Associates Ltd.


Casing Expansion Joint Limited
Flexibility

Charles G. Turner & Associates Ltd.


Casing Hot Spots

Charles G. Turner & Associates Ltd.


External Casing Liquid Refractory
Injection Locations

Charles G. Turner & Associates Ltd.


Thermography Analysis
Transition Duct Liner
Issue Casing Hotspot

Charles G. Turner & Associates Ltd.


Thermography Analysis
Sidewall Bellows Failure Door Seal Leak

Charles G. Turner & Associates Ltd.


External Piping Supports

Charles G. Turner & Associates Ltd.


HEP BEP Supports

Charles G. Turner & Associates Ltd.


HEP BEP Supports

Charles G. Turner & Associates Ltd.


HRSG Superstructure Supports

Charles G. Turner & Associates Ltd.


Duct Burner Blowers

Charles G. Turner & Associates Ltd.


Duct Burner Manifolds

Charles G. Turner & Associates Ltd.


Preheater Recirculation Pump

Charles G. Turner & Associates Ltd.


Pump Inlet Expansion Joint

Charles G. Turner & Associates Ltd.


Preheater Expansion Joint
Misalignment

Charles G. Turner & Associates Ltd.


Preheater Expansion Joint Failure

Charles G. Turner & Associates Ltd.


Lower Vestibules

Charles G. Turner & Associates Ltd.


Chemical Clean Connections

Charles G. Turner & Associates Ltd.


Gasket Leaks

Charles G. Turner & Associates Ltd.


Small Bore Drain Line Pinhole
Leaks

Charles G. Turner & Associates Ltd.


OTSG Side Vestibules

Charles G. Turner & Associates Ltd.


OTSG Sidewall Bundle Restraint

Charles G. Turner & Associates Ltd.


Lower Vestibule and Outlet
Header

Charles G. Turner & Associates Ltd.


Swaged Fitting Tube Plugs

Charles G. Turner & Associates Ltd.


EOR OTSG Vestibule

Charles G. Turner & Associates Ltd.


EOR OTSG Return Bend
Inspection

Charles G. Turner & Associates Ltd.


Drain Lines Inspection

Charles G. Turner & Associates Ltd.


Corrosion Under Insulation

Charles G. Turner & Associates Ltd.


Internally Insulated Gas Tight
Expansion Joint

Charles G. Turner & Associates Ltd.


Removed Drain Line

Charles G. Turner & Associates Ltd.


Corroded Drain Line

Charles G. Turner & Associates Ltd.


Distorted Vestibule Upper
Tubesheet Limit Guide

Charles G. Turner & Associates Ltd.


Tubesheet to Fin Tube Lockup

Charles G. Turner & Associates Ltd.


Upper Vestibule Vent Line
Distortion

Charles G. Turner & Associates Ltd.


Tube Support Module Splay

Charles G. Turner & Associates Ltd.


HRSG Inlet Transition Section

Charles G. Turner & Associates Ltd.


OTSG Steam Outlet Header

Charles G. Turner & Associates Ltd.


Tubesheet Distortion

Charles G. Turner & Associates Ltd.


Tubesheet Witness Marks

Charles G. Turner & Associates Ltd.


Fin Tube to Tubesheet
Ratcheting Effect

Charles G. Turner & Associates Ltd.


Tube Collar Installation

Charles G. Turner & Associates Ltd.


Tube Collar Migration

Charles G. Turner & Associates Ltd.


Tube to Tubesheet Ratcheting
and Collar Movement

Charles G. Turner & Associates Ltd.


OTSG End Gas Seal Plates

Charles G. Turner & Associates Ltd.


OTSG Tube Return Bends

Charles G. Turner & Associates Ltd.


Return Bend Indentation

Charles G. Turner & Associates Ltd.


OTSG Return Bend Indentation

Charles G. Turner & Associates Ltd.


Exhaust Gas Distributor

Charles G. Turner & Associates Ltd.


Exhaust Gas Perforated Plate

Charles G. Turner & Associates Ltd.


Duct Burners

Charles G. Turner & Associates Ltd.


Vertical Duct Burner

Charles G. Turner & Associates Ltd.


Horizontal Configuration
Duct Burner

Charles G. Turner & Associates Ltd.


Duct Burner
Fixed Igniter End

Charles G. Turner & Associates Ltd.


Bat Wing Bluff Body
Configurations

Charles G. Turner & Associates Ltd.


Duct Burner
Floating Element End

Charles G. Turner & Associates Ltd.


Duct Burner Element
Wall Liner Distortion

Charles G. Turner & Associates Ltd.


Duct Burner Pinning

Charles G. Turner & Associates Ltd.


Duct Burner
Cavity Liner Distortion

Charles G. Turner & Associates Ltd.


Duct Burner Cavity
Wall Liner Distortion

Charles G. Turner & Associates Ltd.


Duct Burner Cavity
Liner Replacement

Charles G. Turner & Associates Ltd.


Inlet Duct Insulation Block

Charles G. Turner & Associates Ltd.


Superheater & Reheater Modules

Charles G. Turner & Associates Ltd.


HRSG Bottom Supported
Superheater

Charles G. Turner & Associates Ltd.


Sliding Floor Seal Distortion

Charles G. Turner & Associates Ltd.


Floor Seal Plate Failure

Charles G. Turner & Associates Ltd.


Tube Distortion and Migration

Charles G. Turner & Associates Ltd.


Plug Weld Failures

Charles G. Turner & Associates Ltd.


Scallop Bar Failure & Distortion

Charles G. Turner & Associates Ltd.


Scallop Bar Tube Impingement

Charles G. Turner & Associates Ltd.


Robust Scallop Bar Design

Charles G. Turner & Associates Ltd.


OTSG HP Superheater Tubes

Charles G. Turner & Associates Ltd.


Swollen HP SH Tube

Charles G. Turner & Associates Ltd.


OTSG Tube Rupture

Charles G. Turner & Associates Ltd.


OTSG Circuit Plugging

Charles G. Turner & Associates Ltd.


OTSG SH Ruptured Tube

Charles G. Turner & Associates Ltd.


Freeze Damage

Charles G. Turner & Associates Ltd.


Superheater & Reheater Upper
Vestibule Floor Seal Plates

Charles G. Turner & Associates Ltd.


Upper Header Supports

Charles G. Turner & Associates Ltd.


Top Hung Module
Saddle Supports

Charles G. Turner & Associates Ltd.


Support Saddle Crack

Charles G. Turner & Associates Ltd.


Tube to Header Inspections

Charles G. Turner & Associates Ltd.


Superheater Toe Welds

Charles G. Turner & Associates Ltd.


Lower HP SH & RH Links

Charles G. Turner & Associates Ltd.


Lower SH Drains & Penetrations

Charles G. Turner & Associates Ltd.


Evaporator & Feedwater Modules

Charles G. Turner & Associates Ltd.


Exfoliated Fin Deposits

Charles G. Turner & Associates Ltd.


Feedwater Heater
Vents & Supports

Charles G. Turner & Associates Ltd.


Top Support Systems

Charles G. Turner & Associates Ltd.


Evaporator Support Fixtures

Charles G. Turner & Associates Ltd.


Exhaust Duct and Stack

Charles G. Turner & Associates Ltd.


Heavy Exfoliation and
Sulphur Deposition

Charles G. Turner & Associates Ltd.


Preheater Tube
UT Wall Thickness Monitoring

Charles G. Turner & Associates Ltd.


Exhaust Transition Expansion Joint

Charles G. Turner & Associates Ltd.


Exhaust Duct/Stack Inlet
Expansion Joint

Charles G. Turner & Associates Ltd.


Sulphur Deposits

Charles G. Turner & Associates Ltd.


Sulphur On Stack Floor

Charles G. Turner & Associates Ltd.


Rectangular Duct Damper Blades

Charles G. Turner & Associates Ltd.


Typical Circular Stack
Butterfly Damper

Charles G. Turner & Associates Ltd.


Closed Butterfly Dampers

Charles G. Turner & Associates Ltd.


Stack Silencers

Charles G. Turner & Associates Ltd.


Drum Inspections

Charles G. Turner & Associates Ltd.


Primary Separators, Secondary
Mesh Demisters and Chevrons

Charles G. Turner & Associates Ltd.


Drum Wall Wash Effect

Charles G. Turner & Associates Ltd.


HP Drum Primary Separators and
Demister/Chevron Assemblies

Charles G. Turner & Associates Ltd.


Underside of HP Primary
Separator

Charles G. Turner & Associates Ltd.


HP Drum Floor Deposits

Charles G. Turner & Associates Ltd.


Chevron Separator Failure

Charles G. Turner & Associates Ltd.


Demister Pad Blow Out

Charles G. Turner & Associates Ltd.


Demister Pad/Chevron Assembly
at Saturated Steam Lead

Charles G. Turner & Associates Ltd.


Steam Water Level Line

Charles G. Turner & Associates Ltd.


HP Downcomer Passivation

Charles G. Turner & Associates Ltd.


IP Drum

Charles G. Turner & Associates Ltd.


IP Demister Pads

Charles G. Turner & Associates Ltd.


LP Drum

Charles G. Turner & Associates Ltd.


LP Drum Water Line

Charles G. Turner & Associates Ltd.


LP Feedwater and Evaporator
Riser Distributors

Charles G. Turner & Associates Ltd.


LP Drum Deposits

Charles G. Turner & Associates Ltd.


LP Demister Pads

Charles G. Turner & Associates Ltd.


Door Castellation Seals

Charles G. Turner & Associates Ltd.


Dont Forget the Blowdown Tank

Charles G. Turner & Associates Ltd.


And Remember the Interstage
Attemperators

Charles G. Turner & Associates Ltd.


Tig Weld Cracks

Charles G. Turner & Associates Ltd.


And Borescope Liner Upstream &
Downstream

Charles G. Turner & Associates Ltd.


Now On To Pigging

Charles G. Turner & Associates Ltd.


Cleaning Pig & Before/After
Foam Dewatering Pigs

Charles G. Turner & Associates Ltd.


Feedwater Inlet & Steam Outlet
Borescopes

Charles G. Turner & Associates Ltd.


Pig Launcher

Charles G. Turner & Associates Ltd.


Pig Launchers/Receivers

Charles G. Turner & Associates Ltd.


Borescope Inspection

Charles G. Turner & Associates Ltd.


Pigged Steam Lines

Charles G. Turner & Associates Ltd.


Pigged Gasket Results

Charles G. Turner & Associates Ltd.


Incorporating the Inspection Results into
the LONG TERM MAINTENANCE PLAN

The Long Term Maintenance Plan (LTMP) will define the scope,
frequency and estimated cost of equipment maintenance required to
attain expected plant availability.

The LTMP will be built based on the outputs of the equipment Integrity
Plans and the System Asset Management Plans (SAMP).

Integrity Plans SAMPs LTMP

Objective: Develop Objective: Develop specific Objective: Develop wholistic


equipment specific plans plans utilizing operating plant view on scope, frequency
defining maintenance intervals, assumptions and performance and cost of outages over 5 and
related projects and applicable history 20 year horizons
operating procedures.

Charles G. Turner & Associates Ltd.


LTMP & Business Plan
LTMP Linkage with the Annual Business Plan

The LTMP will include the following;


Discussion on Integrity Plans and SAMP content as it relates
to the long term maintenance requirements.
Short term view showing major outage work scopes, durations
and cost estimates.
Long term view showing major outage work scopes, durations
and cost estimates.
With the combination of Integrity Plans and SAMPs in the LTMP,
which should be reviewed and updated on an annual basis, the
annual Business Plan will contain an accurate maintenance scope,
duration and cost estimates for the coming year.

Charles G. Turner & Associates Ltd.


Incorporating the Inspection
Findings into a Risk Registry
The Risk Registry is a tool used to document risks known
to Management and associated mitigation activities.
As a group the management team distributes risks
appropriately to team members, who become the risk
manager.
The Risk Manager is responsible for documenting current
mitigation activities or developing strategies for further
mitigation when appropriate.

Charles G. Turner & Associates Ltd.


Calculate Risk Value
A Risk Value is calculated using the probability, frequency
and impact values.

Charles G. Turner & Associates Ltd.


A Wholistic Approach to HRSG
Inspections
Concluding remarks:
Know what you are up against.
Begin the inspection with the end in
mind.
Understand the deliverables of the
inspection.
Hope for the best, prepare for the
worst.

Charles G. Turner & Associates Ltd.


Thank you for your
time & interest.
Questions?

Charles G. Turner & Associates Ltd.