V100R005C00
Performance Monitoring
Reference
Issue Draft B
Date 2012-07-24
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not
be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all
statements, information, and recommendations in this document are provided "AS IS" without warranties,
guarantees or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Contents
Purpose
This document describes the information about eNodeB-related performance monitoring tasks,
including:
The descriptions of parameters for performance monitoring
The descriptions of monitor items
The value range of each monitor item
The formula used to calculate the value of each monitor item
Product Versions
The following table lists the product version related to this document.
Intended Audience
This document is intended for:
System engineers
Site maintenance engineers
Change History
The following describes the changes in eNodeB Performance Monitoring Reference.
The document issues are as follows:
Draft B(2012-07-24)
Draft A (2012-06-29)
Draft B (2012-07-24)
This is draft B.
Compared with issue draft A (2012-06-29) of V100R005C00, this issue includes the following
new information.
Compared with draft A (2012-06-29) of V100R005C00, this issue does not include any
changes.
No information in issue draft A (2012-06-29) of V100R005C00 is deleted from this issue.
Draft A (2012-06-29)
This is draft A.
2 Introduction
2.1 Overview
Performance monitoring is used to monitor the equipment running status and service status of
eNodeBs by using iManager M2000 Mobile Element Management System (referred to as
M2000) or the local maintenance terminal (LMT). Monitoring results are displayed in tables
or charts. In this way, equipment can be maintained and faults can be rectified by analyzing
the exceptions shown in monitoring results.
3.1.3 Parameters
Table 3-1 Parameters for CPU usage monitoring
Parameter Description
Cabinet No. Number of the cabinet where the board is located.
Subrack No. Number of the subrack where the board is located.
Slot No. Number of the slot where the board is located.
Monitor Period Interval of reporting monitoring results. It is set to the fixed value 5.
(Seconds)
4.1.3 Parameters
Table 4-1 Parameters for CPRI BER monitoring
Parameter Description
Upper Cabinet NO. The cabinet number of the upper-level node at the other end of the
monitored link.
Parameter Description
5.1.3 Parameters
Table 5-1 Parameters for RRU/RFU Output Power monitoring
Parameter Description
Cabinet No. Number of the cabinet where the board for RRU/RFU Output Power
monitoring is located.
Subrack No. Number of the subrack where the board for RRU/RFU Output Power
monitoring is located.
Slot No. Number of the slot where the board for RRU/RFU Output Power
monitoring is located.
Monitor Period Interval of reporting monitoring results. It can be set to 1000,2000, or
(ms) 3000.
5.2.3 Parameters
Table 5-3 Parameters for RRU/RFU Temperature monitoring
Parameter Description
Cabinet No. Number of the cabinet where the board for RRU/RFU temperature
monitoring is located.
Subrack No. Number of the subrack where the board for RRU/RFU temperature
monitoring is located.
Slot No. Number of the slot where the board for RRU/RFU temperature
monitoring is located.
Monitor Period Interval of reporting monitoring results. It can be set to 1000,2000, or
(ms) 3000.
5.3.3 Parameters
Table 5-5 Parameters for sector performance monitoring
Parameter Description
Test Items It can be set only to UL Widefreq Scan.
Monitor Period Interval of reporting monitoring results. It can be set to 50, 100, 200,
(ms) 500, 1000, or 2000.
Local Sector ID ID of the sector for performance monitoring.
Frequency Band Frequency band supported by the sector. It is set to a value in the range
of 1 to 40.
Parameter Description
UL EARFCN Uplink EARFCN of a cell. It is set to a value in the ranges of 18000 to
45589 and 64436 to 65535.
UL Bandwidth Uplink bandwidth of the cell. It can be set to 1.4M, 3M, 5M, 10M,
15M, or 20M.
5.4.3 Parameters
Table 5-7 Parameters for spectrum detection
Parameter Description
Scan Mode Detects the output power of each TX channel and carrier. It can be set
to Carrier Mode, Channel Current Band Mode, or Channel Full
Band Mode.
Parameter Description
located.
Slot No. Number of the slot where the board for spectrum detection is located.
RBW(Resolutio Time frequency of Fast Fourier Transport (FFT) frequency detection, in
n Bandwidth) units of kHz.
The value range for online high-precision frequency detection is 15
to 200. The default value is 100.
The value range for online or offline wideband frequency detection
is 100 to 5000. The default value is 200.
Monitor Period Interval of reporting monitoring results. It can be set to 1000, 2000, or
(ms) 3000.
Scan Mode The Autosave to File check box is selected by default, and monitoring
results are automatically saved in the default path. You can also
customize the file name, file format, and another save path.
6.1.3 Parameters
Table 6-1 Parameters for IP link monitoring
Parameter Description
Test Items It can be set to the following values:
FE/GE
TUNNEL
Cabinet No. Number of the cabinet where the board for IP link monitoring is
located.
Subrack No. Number of the subrack where the board for IP link monitoring is
located.
Slot No. Number of the slot where the board for IP link monitoring is located.
Parameter Description
FE/GE.
Tunnel No. Number of the tunnel for IP link monitoring. It needs to be set
only when the Test Items is set to TUNNEL.
6.2.3 Parameters
Table 6-3 Parameters for IP path performance monitoring
Parameter Description
IP PATH No. Number of the IP path.
Monitor Period Interval of reporting monitoring results. It is set to 1 by default.
(Seconds)
6.3.3 Parameters
Table 6-5 Parameters for IP performance monitoring
Parameter Description
Cabinet No. Number of the cabinet where the board for IP performance monitoring
is located.
Parameter Description
Subrack No. Number of the subrack where the board for IP performance monitoring
is located.
Slot No. Number of the slot where the board for IP performance monitoring is
located.
Monitor Period Interval of reporting monitoring results. It is set to 1 by default.
(Seconds)
6.4.3 Parameters
Table 6-7 Parameters for SCTP performance monitoring
Parameter Description
Cabinet No. Number of the cabinet where the board for SCTP performance
Parameter Description
monitoring is located.
Subrack No. Number of the subrack where the board for SCTP performance
monitoring is located.
Slot No. Number of the slot where the board for SCTP performance monitoring
is located.
Monitor Period Interval of reporting monitoring results. It is set to 1 by default.
(Seconds)
6.5.3 Parameters
Table 6-9 Parameters for transmission performance monitoring
Parameter Description
Parameter Description
performance monitoring is located. This can be selected when
Test Items is set to PPP Performance.
MPGroup No. Number of the MP group where the board for transmission
performance monitoring is located. This can be selected when
Test Items is set to MP Performance.
PPP Performance
MP Performance
6.6.3 Parameters
Table 6-13 Parameters for UDP injection test monitoring
Parameter Description
Cabinet No. Number of the cabinet where the board for the UDP test is
located.
Subrack No. Number of the subrack where the board for the UDP test is
located.
Slot No. Number of the slot where the board for the UDP test is located.
Monitor Period Interval of reporting monitoring results. It is set to 1 by default.
(Seconds)
Source IP Address IP address of the eNodeB.
Source Port No. Number of UDP port on the eNodeB. The value ranges from
1024 to 65,535.
Destination IP Address IP address of the peer end.
Destination Port No Number of UDP port on the peer end. The value ranges from
1024 to 65,535.
DSCP Differentiated services code point (DSCP) of the UDP packet.
The value ranges from 0 to 63. The default value is 63.
Speed (Kbps) Data rate of the data transmission. The value ranges from 28 to
150,000. The default value is 150000.
UDP PACKETS Length of the UDP packet. The value ranges from 72 to 1500.
LENGTH (BYTES) The default value is 1500.
Time (Minutes) Duration of UDP test monitoring. The test stops
automatically when the duration expires. The value ranges from 1
to 60. The default value is 15.
6.7.3 Parameters
Table 6-15 Parameters for local and forwarded traffic monitoring
Parameter Description
Monitor Period (Seconds) Interval of reporting monitoring results. It is set to 1 by
default.
6.8.3 Parameters
Table 6-17 Parameters for resource group monitoring
Parameter Description
Cabinet No. Number of the cabinet where the board for resource group
monitoring is located.
Subrack No. Number of the subrack where the board for resource group
monitoring is located.
Slot No. Number of the slot where the board for resource group
monitoring is located.
SubBoard Type Type of the subboard for resource group monitoring.
Physical Port Type Type of the physical port for resource group monitoring.
Physical Port No. Number of the physical port for resource group monitoring.
Transmission Resource Number of the transport resource group for resource group
Group No. monitoring.
Rate Config Type Rate mode for resource group monitoring. It can be single-rate
mode or double-rate mode.
Monitor Period (ms) Interval of reporting monitoring results. It can be set to 50, 100,
200, 500, 1000, or 2000.
Dual Rate
6.9.3 Parameters
Table 6-20 Parameters for PPPoE performance monitoring
Parameter Description
Cabinet No. Number of the cabinet where the board for the PPPoE performance
tests is located.
Subrack No. Number of the subrack where the board for the PPPoE performance
tests is located.
Slot No. Number of the slot where the board for the PPPoE performance tests is
located.
PPPoELink No. Number of the PPPoE link to be tested.
7.1.3 Parameters
Table 7-1 Parameters for service satisfaction monitoring
Parameter Description
Test Items It can be set to DL QCI1 Satisfaction rate of Service, DL QCI2
Satisfaction rate of Service, DL QCI3 Satisfaction rate of
Service, DL QCI4 Satisfaction rate of Service, UL QCI1
Satisfaction rate of Service, UL QCI2 Satisfaction rate of Service,
UL QCI3 Satisfaction rate of Service, UL QCI4 Satisfaction rate
of Service, GBR Degrade Flag, or a combination of some items.
Local Cell ID ID of the cell on which satisfaction of service monitoring is
performed.
CN Operator ID In a RAN sharing scenario, a cell can be shared by a maximum of
four operators. You can choose one or more operators.
In a non-RAN sharing scenario, this parameter is set to 0 by default.
Monitor Period Interval of reporting monitoring results. It can be set to 50, 100, 200,
(ms) 500, 1000, or 2000.
7.2.3 Parameters
Table 7-3 Parameters for general throughput monitoring
Parameter Description
Local Cell ID ID of the cell on which general throughput monitoring is
performed.
Test Items It can be set to RLC Throughput, RLC Throughput of GBR
service, RLC Throughput of NON-GBR service, or a
combination of some items.
CN Operator ID In a RAN sharing scenario, a cell can be shared by a maximum of
four operators. You can choose one or more operators.
In a non-RAN sharing scenario, this parameter is set to 0 by
default.
Monitor Period (ms) Interval of reporting monitoring results. It can be set to 50, 100,
200, 500, 1000, or 2000.
7.3.3 Parameters
Table 7-7 Parameters for service statistics monitoring
Parameter Description
7.4.3 Parameters
Table 7-9 Parameters for user statistics monitoring
Parameter Description
Test Items It can be set to Keep UL Synch Users Number, General Users
Number, NO-Activated Users Number, or a combination of some
items.
Local Cell ID ID of the cell on which user statistics monitoring is performed.
CN Operator ID In a RAN sharing scenario, a cell can be shared by a maximum of
four operators. You can choose one or more operators. In a non-RAN
sharing scenario, this parameter is set to 0 by default.
Monitor Period Interval of reporting monitoring results. It can be set to 50, 100, 200,
(ms) 500, 1000, or 2000.
7.5.3 Parameters
Table 7-13 Parameters for RB usage monitoring
Parameter Description
7.6.3 Parameters
Table 7-15 Parameters for ICIC monitoring
Parameter Description
OI information
7.7.3 Parameters
Table 7-21 Parameters for MU-MIMO monitoring
Parameter Description
Local Cell ID ID of the cell on which MU-MIMO monitoring is performed.
Monitor Period Interval of reporting monitoring results. It can be set to 50, 100, 200,
(ms) 500, 1000, or 2000.
7.8.3 Parameters
Table 7-23 Parameters for interference RSSI statistic detect monitoring
Parameter Description
Local Cell ID ID of the cell on which interference RSSI statistic detect monitoring
is performed.
Monitor Period (ms) Interval of reporting monitoring results. It can be set to 50, 100,
200, 500, 1000, or 2000.
7.9.3 Parameters
Table 7-25 Parameters for interference detection monitoring
Parameter Description
Local Cell ID ID of the cell on which interference detection monitoring is
performed.
Monitor Period (ms) Interval of reporting monitoring results. It can be set to 50, 100,
200, 500, 1000, or 2000.
7.10.3 Parameters
Table 7-27 Parameters for scheduled cell-level UE information monitoring
Parameter Description
Local Cell ID ID of the cell on which scheduled users statistic monitoring is
performed.
Monitor Period Interval of reporting monitoring results. It can be set to 50, 100, 200,
Parameter Description
(ms) 500, 1000, or 2000.
7.11.3 Parameters
Table 7-29 Parameters for HARQ status monitoring
Parameter Description
Test Items It can be set to DL HARQ State, UL HARQ State, or a combination
of the items.
Local Cell ID ID of the cell on which HARQ statistic monitoring is performed.
Monitor Period Interval of reporting monitoring results. It can be set to 1000 or 2000.
(ms)
UL HARQ State
7.12.3 Parameters
Table 7-32 Parameters for air-interface DCI status monitoring
Parameter Description
Test Items It can be set to DCI STATISTIC.
Local Cell ID ID of the cell on which DCI statistic monitoring is performed.
Monitor Period Interval of reporting monitoring results. It can be set to 1000 or
(ms) 2000.
7.13.3 Parameters
Table 7-34 Parameters for air-interface DRB statistics monitoring
Parameter Description
Test Items It can be set to DL DRB STATISTIC, UL DRB STATISTIC, or a
combination of the items.
Local Cell ID ID of the cell on which DRB statistics monitoring is performed.
Monitor Period Interval of reporting monitoring results. It can be set to 1000 or 2000.
(ms)
UL DRB STATISTIC
8.1.3 Parameters
Table 8-1 Parameters for DL RSRP/RSRQ monitoring
Parameter Description
8.2.3 Parameters
Table 8-3 Parameters for BLER monitoring
Parameter Description
Test Items It can be set to Init BLER, Resident BLER, PDCCH BLER, or a
combination of these items.
UEID-MME MME of a user.
UEID-TMSI/Trace TMSI or trace reference number to be monitored.
Reference No.
Monitor Period (ms) Interval of reporting monitoring results. It can be set to 50, 100,
200, 500, 1000, or 2000.
Resident BLER
PDCCH BLER
8.3.3 Parameters
Table 8-7 Parameters for power headroom monitoring
Parameter Description
UEID-MME MME of a user.
UEID-TMSI/Tra TMSI or trace reference number to be monitored.
ce Reference No.
Monitor Period Interval of reporting monitoring results. It can be set to 50, 100, 200,
Parameter Description
(ms) 500, 1000, or 2000.
8.4.3 Parameters
Table 8-9 Parameters for channel quality monitoring
Parameter Description
Test Items It can be set to SINR, CQI, or a combination of the items.
Signal to interference and noise ratio (SINR) indicates the uplink
channel quality of the UE.
CQI indicates the downlink channel quality of the UE.
UEID-MME MME of a user.
UEID-TMSI/Trac TMSI or trace reference number to be monitored.
e Reference No.
Monitor Period Interval of reporting monitoring results. It can be set to 50, 100, 200,
Parameter Description
(ms) 500, 1000, or 2000.
CQI
8.5.3 Parameters
Table 8-12 Parameters for scheduling monitoring
Parameter Description
Test Items It can be set to UL SR of Service, UL BSR of Service, Percentage
of DRX activity timer in DRX timer, or a combination of these
items.
UEID-MME MME of a user.
UEID-TMSI/Tra TMSI or trace reference number to be monitored.
ce Reference No.
Monitor Period Interval of reporting monitoring results. It can be set to 50, 100, 200,
(ms) 500, 1000, or 2000.
UL BSR of Service
Table 8-15 Results of Percentage of DRX activity timer in DRX timer monitoring
8.6.3 Parameters
Table 8-16 Parameters for RLC data stream monitoring
Parameter Description
UEID-MME MME of a user.
UEID-TMSI/Tra TMSI or trace reference number to be monitored.
ce Reference No.
Monitor Period Interval of reporting monitoring results. It can be set to 50, 100, 200,
(ms) 500, 1000, or 2000.
8.7.3 Parameters
Table 8-18 Parameters for throughput monitoring
Parameter Description
Parameter Description
(ms) 500, 1000, or 2000.
Throughput of MAC
8.8.3 Parameters
Table 8-21 Parameters for AQM monitoring
Parameter Description
Test Items It can be set to Percentage of AQM discard package, DL RLC
buffer length of eNodeB, or a combination of the items.
UEID-MME MME of a user.
UEID-TMSI/Trac TMSI or trace reference number to be monitored.
e Reference No.
Monitor Period Interval of reporting monitoring results. It can be set to 50, 100, 200,
(ms) 500, 1000, or 2000.
8.9.3 Parameters
Table 8-23 Parameters for uplink power control monitoring
Parameter Description
Test Items It can be set to Close-loop Power of UE, PUSCH N max updated of
UE, PUCCH ACK/NACK/DTX Statistic, or a combination of these
items.
UEID-MME MME of a user.
UEID-TMSI/Tra TMSI or trace reference number to be monitored.
ce Reference No.
Monitor Period Interval of reporting monitoring results. It can be set to 50, 100, 200,
(ms) 500, 1000, or 2000.
8.10.3 Parameters
Table 8-27 Parameters for downlink power control monitoring
Parameter Description
Test Items It can be set to PDSCH of UE, PHICH of UE, PDCCH of UE, or a
combination of these items.
UEID-MME MME of a user.
UEID-TMSI/Trac TMSI or trace reference number to be monitored.
Parameter Description
e Reference No.
Monitor Period Interval of reporting monitoring results. It can be set to 50, 100, 200,
(ms) 500, 1000, or 2000.
PHICH UE
PDCCH UE
8.11.3 Parameters
Table 8-31 Parameters for uplink ICIC monitoring
Parameter Description
Test Items It can be set to USER PROPERTY or USER NEIGHBOR LIST.
You can also select both test items for simultaneous monitoring.
UEID-MME MME of a user.
UEID-TMSI/Trac TMSI or trace reference number to be monitored.
e Reference No.
Monitor Period Interval of reporting monitoring results. It can be set to 50, 100, 200,
(ms) 500, 1000, or 2000.
8.12.3 Parameters
Table 8-34 Parameters for MCS statistics monitoring
Parameter Description
Test Items It can be set to DL MCS or UL MCS. You can also select both test
items for simultaneous monitoring.
UEID-MME MME of a user.
UEID-TMSI/Tra TMSI or trace reference number to be monitored.
ce Reference No.
Monitor Period Interval of reporting monitoring results. It can be set to 1000 or 2000.
(ms)
UL MCS
9.1.3 Parameters
Table 9-1 Parameters for clock quality test monitoring
Parameter Description
Cabinet No. Number of the cabinet where the board for clock quality test
monitoring is located.
Subrack No. Number of the subrack where the board for clock quality test
monitoring is located.
Slot No. Number of the slot where the board for clock quality test monitoring is
located.
9.2.3 Parameters
Table 9-3 Parameters for IP clock data collection
Parameter Description
Cabinet No. Number of the cabinet where the board for IP clock data collection is
located.
Subrack No. Number of the subrack where the board for IP clock data collection is
located.
Slot No. Number of the slot where the board for IP clock data collection is
located.