Você está na página 1de 38

Steel Deck

A division of Canam Group


TABLE OF CONTENTS
PAGE PAGE
OUR SERVICES ............................................................................. 4 P-3012 FORM DECK
DIMENSIONS & PHYSICAL PROPERTIES ............................... 22
NOTES ABOUT LOAD TABLES ........................................................... 5 MAXIMUM CONCRETE SLAB THICKNESS TABLE ..................... 23
FACTORED RESISTANCE OF CONCRETE SLAB WITH WIRE MESH ... 23
P-3615 & P-3606
DIMENSIONS & PHYSICAL PROPERTIES ................................. 6 DESIGN AIDS
FACTORED AND SERVICE LOADS .......................................... 7 WEB CRIPPLING ............................................................. 24
ROOF CANTILEVER .......................................................... 26
P-2436 & P-2404 FLOOR CANTILEVER ......................................................... 27
DIMENSIONS & PHYSICAL PROPERTIES ................................. 8 POUR STOP ................................................................... 28
CLOSURE STRIP ............................................................. 29
FACTORED AND SERVICE LOADS .......................................... 9
ACCESSORIES
P-3615 & P-3606 COMPOSITE PLATES & SUMP PAN ..................................................... 30
DIMENSIONS & PHYSICAL PROPERTIES ............................... 10 NEOPRENE & METAL CLOSURES ........................................ 31
FACTORED RESISTANCE OF COMPOSITE SLAB ....................... 11
DECK FEATURES
WITH LIGHTWEIGHT CONCRETE .................................. 13 VENTED DECK ................................................................ 32
ACOUSTICAL DECK .......................................................... 33
P-3623 COMPOSITE
DIMENSIONS & PHYSICAL PROPERTIES ............................... 14 CANAM DECK CERTIFICATION
FACTORED RESISTANCE OF COMPOSITE SLAB ....................... 15 FACTORY MUTUAL (FM).................................................. 34
UNDERWRITERS LABORATORIES OF CANADA (ULC) ............. 34
WITH LIGHTWEIGHT CONCRETE .................................. 17
DIAPHRAGM ............................................................................... 36
P-2432 COMPOSITE
DIMENSIONS & PHYSICAL PROPERTIES ............................... 18 BUSINESS UNITS & INTERNET ADDRESSES ...................................... 37
FACTORED RESISTANCE OF COMPOSITE SLAB ....................... 19 CANAM ADDRESSES ..................................................................... 38
WITH LIGHTWEIGHT CONCRETE .................................. 21

Utility / Product P-3615 P-3606 P-2436 P-2404 P-3623 P-2432 P-3012


Roof Deck
Floor Deck (Composite)
Form Deck (Non Composite)
Deck Features
Vented Deck
Acoustical Deck
Technical Data
Diaphragm
Depth 38 mm (1 1/2) 38 mm (1 1/2) 76 mm (3) 76 mm (3) 51 mm (2) 76 mm (3) 14 mm (9/16)
Coverage 914 mm (36) 914 mm (36) 610 mm (24) 610 mm (24) 914 mm (36) 610 mm (24) 762 mm (30)

Request for technical information about our cold-formed products can be sent to: steeldeck@canam.ws

3
OUR SERVICES
For project design, bid preparation or component manufacturing, our sales representatives, engineers,
technicians and draftsmen are at your service. Our team can suggest efficient and economical solutions.

DRAWINGS
Canam produces its own shop drawings for the
fabrication of your steel joists, trusses, steel deck and girts.

FABRICATION
Our production equipment has always been at the
leading edge of technology. We have continued to invest
significantly to acquire the best available equipment in the
industry, including computer-aided manufacturing and
numerically-controlled machinery. Canam has an automated
roll former for girts as well as several steel deck roll formers.

DELIVERY
Canams advantage has always been our ability
to deliver just on time, regardless of where or when you need
our products. We know that your on-site erection crews can
not afford to wait. For this reason, our trucks and semitrailers
travel the continent, around the clock, to satisfy the
requirements of your construction schedules.

4
NOTES ABOUT LOAD TABLES
STANDARDS
This Canam steel deck catalog presents load tables
based on the recent edition of the standard CAN/CSA-S136-01
North American Specification for the Design of Cold-Formed
Steel Structural Members.
In Canada, design shall be made under Limit States
Design principles. For this reason, the uniform loads shown
in the tables are the maximum factored loads that the deck
can support.
The Canadian Sheet Steel Building Institute (CSSBI)
specifies rules for steel deck practices. As a member of this
organization, Canam applied those rules in the calculations
for this catalog. The designer has the responsibility to follow
practices published by the CSSBI for Canadian projects.

WARNING
Although every effort was made to ensure that all data in this
catalog is factual and that the numerical values are accurate to a
degree consistent with cold-formed design standards, Canam does
not assume responsibility for errors or oversights that may result
from the use of the information contained herein. Anyone making
use of the contents of this catalog assumes all liability arising from
such use. All suggestions for improvements to this publication will
receive full consideration for future printings.

GRADE AND RESISTANCE


The latest version of the ASTM A 653M standard EMBOSSMENTS AND PERFORATIONS
recognizes 7 different structural quality steels with their The P-3615, P-3606, P-3623 and P-2432 deck profiles
chemical composition and mechanical properties. The sheet are available with embossments to act in composite action
steels normally used to form Canam steel deck profiles with a concrete slab. Tables for these composite sections
correspond to ASTM A 653M SS Grade 230. They have a show loads and unshored spans for normal weight concrete
yield strength of 230 MPa (33 ksi) and a tensile strength of and light weight concrete on separate pages.
310 MPa (45 ksi). Steel with higher yield strength or different The P-3615, P-3606, P-2436 and P-2404 deck profiles are
ASTM designation can be used to meet specific needs. available with perforated web elements that reduce noise rever-
beration when fiberglass insulation strips are installed according
THICKNESS to the assembly instructions for acoustical deck (refer to
CAN/CSA-S136-01 standard for the design of page 33). The resistance values of acoustical deck are
cold-formed steel structural members indicates that the considered to be 95% of those shown in the tables.
thickness supplied shall not be less than 95% of the
design thickness used. The generally accepted thickness SHORTER LENGTHS
of the zinc coating of a Z275 (G90) finish is approximately Upon special request made to our sales department,
0.040 mm (0.0015 in.). sheets are available in lengths of less than 1 800 mm (6 feet).
STAINLESS STEEL CONCENTRATED LOADS
Upon request, we can provide stainless steel or steel The loads indicated in the tables are uniformly distributed
protected by an aluminium-zinc coating. However, costs, and must not be used as the equivalent of point loads or linear
availability and delivery schedules must be discussed with loads. Proper analysis should be done by an engineer to verify
our sales department. Most of the stainless steel types have the effects of those concentrated loads on the deck or
a yield strength of 205 MPa (30 ksi). The resistance values composite deck-slab.
of stainless steel deck are considered to be 90% of those
shown in the tables. For example:
The wheel load of rolling equipment on the steel
COATING deck during roofing material installation.
The large spacing between attachments of roofing
Canam steel deck profiles are available with Z275 (G90)
material to steel deck under uplift conditions.
or ZF75 (A25) zinc protection according to the standard
ASTM A 653M. Upon request, Canam can also provide The footprint of a concentrated load on a slab.
finish paint from the 8000 color series with an underlying Concentrated loads shall be analyzed to ensure they do
zinc protection of Z275 (G90), or other types of material, not overstress the steel deck or the composite deck-slab locally.
given sufficient notice.

5
P-3615 & P-3606
Canams steel deck profiles P-3615 and P-3606 are roll formed to cover 914 mm (36 in.).
The deck is available with a galvanized coating according to the standard
ASTM A 653M with zinc thickness corresponding to Z275 (G90) or
ZF75 (A25). Upon agreement with our sales department,
it is also possible to obtain steel deck with
aluminium-zinc coating according
to designation AZM150
(AZ50) of the
standard
ASTM A 792M.
Nominal thicknesses range
from 0.76 mm (0.030 in.)
to 1.52 mm (0.060 in.). The flutes
are 38 mm (1.5 in.) deep and are spaced
at 152 mm (6 in.) center to center. The deck
can be rolled to lengths from 1 800 mm
(6 ft.) to 12 200 mm (40 ft.).

DIMENSIONS
914 mm (36)

38 mm
(1 1/2)
64 mm 89 mm 38 mm 114 mm
P-3615 (2 1/2) (3 1/2) (1 1/2) (4 1/2)
152 mm (6)

914 mm (36)

38 mm
(1 1/2)
64 mm 89 mm 38 mm 114 mm
P-3606 (2 1/2) (3 1/2) (1 1/2) (4 1/2)
152 mm (6)

PHYSICAL PROPERTIES
Nominal Design Overall Section Modulus Moment of Inertia
Type Weight
Thickness Thickness Depth M+ M for Deflection
mm mm mm kg/m2 mm 3 mm3 mm4
(in.) (in.) (in.) (lb/ft2) 3
(in ) (in3) (in4)
0.76 0.762 37.4 8.50 9 529 10 081 202 228
22
(0.030) (0.0300) (1.47) (1.74) (0.1772) (0.1875) (0.1481)
0.91 0.909 37.5 10.07 11 558 12 005 254 750
20
(0.036) (0.0358) (1.48) (2.06) (0.2150) (0.2233) (0.1865)
1.21 1.217 37.8 13.26 15 813 15 994 363 493
18
(0.048) (0.0479) (1.49) (2.72) (0.2941) (0.2975) (0.2662)
1.52 1.511 38.1 16.34 19 786 19 786 452 472
16
(0.060) (0.0595) (1.50) (3.35) (0.3680) (0.3680) (0.3313)

Effective properties are based on a unit width of 1 000 mm (S.I. units) or 12 in. (imperial units).
Material according to ASTM A 653M SS Grade 230, yield strength of 230 MPa (33 ksi).
Tables are calculated according to CAN/CSA-S136-01 standard.

6
P-3615 & P-3606
FACTORED AND SERVICE LOADS TABLE (kPa) METRIC
Nominal SPAN (mm)
Type
Thickness (mm) 1 200 1 350 1 500 1 650 1 800 1 950 2 100 2 250 2 400 2 550 2 700 2 850 3 000
SINGLE SPAN
F 10.69 8.49 6.90 5.72 4.82
22 0.76
D 7.60 5.34 3.89 2.92 2.25
F 12.95 10.29 8.37 6.93 5.84 4.98
20 0.91
D 9.58 6.73 4.90 3.68 2.84 2.23
F 17.70 14.06 11.44 9.48 7.98 6.82 5.89 5.13
18 1.21
D 13.66 9.60 7.00 5.26 4.05 3.18 2.55 2.07
F 22.14 17.59 14.31 11.86 9.99 8.53 7.36 6.42 5.65
16 1.52
D 17.01 11.95 8.71 6.54 5.04 3.96 3.17 2.58 2.13
DOUBLE SPAN
F 11.11 8.85 7.22 5.99 5.05 4.32 3.73
22 0.76
D 18.31 12.86 9.38 7.04 5.43 4.27 3.42
F 13.23 10.54 8.59 7.14 6.02 5.14 4.44 3.88
20 0.91
D 23.07 16.20 11.81 8.87 6.84 5.38 4.30 3.50
F 17.63 14.05 11.45 9.51 8.02 6.85 5.92 5.17 4.55 4.03 3.60
18 1.21
D 32.92 23.12 16.85 12.66 9.75 7.67 6.14 4.99 4.11 3.43 2.89
F 21.82 17.39 14.17 11.77 9.92 8.48 7.33 6.39 5.63 4.99 4.46 4.00 3.62
16 1.52
D 40.97 28.78 20.98 15.76 12.14 9.55 7.65 6.22 5.12 4.27 3.60 3.06 2.62
TRIPLE SPAN
F (13.60) 10.88 8.90 7.40 6.25 5.35 4.63 4.04
22 0.76
D 14.35 10.08 7.35 5.52 4.25 3.34 2.68 2.18
F 16.19 12.96 10.59 8.82 7.45 6.37 5.51 4.82 4.24 3.77
20 0.91
D 18.08 12.70 9.26 6.96 5.36 4.21 3.37 2.74 2.26 1.88
F 21.59 17.27 14.12 11.75 9.93 8.49 7.35 6.42 5.65 5.02 4.48 4.03
18 1.21
D 25.80 18.12 13.21 9.92 7.64 6.01 4.81 3.91 3.22 2.69 2.26 1.93
F 26.72 21.38 17.47 14.54 12.28 10.51 9.09 7.94 6.99 6.21 5.55 4.98 4.50
16 1.52
D 32.11 22.56 16.44 12.35 9.52 7.48 5.99 4.87 4.01 3.35 2.82 2.40 2.06

FACTORED AND SERVICE LOADS TABLE (psf) IMPERIAL


Nominal SPAN (ft.-in.)
Type
Thickness (in.) 4-0 4-6 5-0 5-6 6-0 6-6 7-0 7-6 8-0 8-6 9-0 9-6 10-0
SINGLE SPAN
F 216 172 140 116 97
22 0.030
D 151 106 78 58 45
F 262 208 169 140 118 101
20 0.036
D 191 134 98 73 57 44
F 358 285 232 192 162 138 119 104
18 0.048
D 272 191 139 105 81 63 51 41
F 448 356 290 240 202 173 149 130 114
16 0.060
D 339 238 173 130 100 79 63 51 42
DOUBLE SPAN
F 225 179 146 121 102 87 76
22 0.030
D 365 256 187 140 108 85 68
F 268 214 174 144 122 104 90 78
20 0.036
D 459 323 235 177 136 107 86 70
F 357 285 232 193 162 139 120 105 92 82 73
18 0.048
D 655 460 336 252 194 153 122 99 82 68 58
F 442 352 287 238 201 172 148 129 114 101 90 81 73
16 0.060
D 816 573 418 314 242 190 152 124 102 85 72 61 52
TRIPLE SPAN
F 276 220 180 150 127 108 94 82
22 0.030
D 286 201 146 110 85 67 53 43
F 328 263 215 179 151 129 112 98 86
20 0.036
D 360 253 184 139 107 84 67 55 45
F 438 350 286 238 201 172 149 130 114 102 91
18 0.048
D 514 361 263 198 152 120 96 78 64 54 45
F 542 433 354 294 249 213 184 161 142 126 112 101 91
16 0.060
D 640 449 327 246 189 149 119 97 80 67 56 48 41

Loads in rows marked F are the maximum factored loads controlled Web crippling controls loads in brackets calculated with the end
by the bending capacity, and those in rows marked D are the uniform bearing length equal to 40 mm (1.6 in.) and the interior bearing
service loads that produce a deflection of L/240. length equal to 102 mm (4 in.). Refer to page 24 for web crippling
tables and examples.
Loads in rows marked F should be compared to factored loads
according to CAN/CSA-S16-01 Limit States Design of Steel Structure. The span is the shortest of the following dimensions: dimension c/c of
the supports, or the clear dimension between the supports plus the
The live loads producing deflection equal to the span/180 or span/360 depth of the deck at each end.
can be calculated by multiplying the loads in the D rows by 1.33 or
0.66 respectively. Refer to page 34 for maximum spans approved by Factory Mutual (FM).

7
P-2436 & P-2404
Canams steel deck profiles P-2436 and P-2404 are roll formed to cover 610 mm (24 in.).
The deck is available with a galvanized coating according to the standard
ASTM A 653M with zinc thickness corresponding to Z275 (G90)
or ZF75 (A25). Upon agreement with our sales
department, it is also possible to obtain
steel deck with aluminium-zinc coating
according to designation
AZM150 (AZ50) of the
standard ASTM A 792M.
Nominal thicknesses range
from 0.76 mm (0.030 in.)
to 1.52 mm (0.060 in.).
The flutes are 76 mm (3 in.)
deep and are spaced at 152 mm (6 in.)
center to center. The deck can be rolled to
lengths from 1 800 mm (6 ft.) to 12 200 mm (40 ft.).

DIMENSIONS
610 mm (24)
76 mm
(3)
152 mm
(6) 89 mm
P-2436 (3 1/2)
38 mm 114 mm 64 mm
(1 1/2) (4 1/2) (2 1/2)

610 mm (24)
76 mm
(3)
152 mm
(6) 89 mm
P-2404 (3 1/2)
38 mm 114 mm 64 mm
(1 1/2) (4 1/2) (2 1/2)

PHYSICAL PROPERTIES
Nominal Design Overall Section Modulus Moment of Inertia
Type Weight
Thickness Thickness Depth M+ M for Deflexion
mm mm mm kg/m2 mm 3 mm3 mm4
(in.) (in.) (in.) (lb/ft2) (in3) (in3) (in4)
0.76 0.762 76.2 11.85 24 134 25 690 1 006 306
22
(0.030) (0.0300) (3.00) (2.43) (0.4489) (0.4778) (0.7369)
0.91 0.909 76.4 14.04 29 407 31 169 1 262 487
20
(0.036) (0.0358) (3.01) (2.88) (0.5470) (0.5797) (0.9245)
1.21 1.217 76.7 18.33 40 633 41 655 1 819 220
18
(0.048) (0.0479) (3.02) (3.75) (0.7558) (0.7748) (1.3322)
1.52 1.511 77.0 22.71 51 473 51 681 2 294 846
16
(0.060) (0.0595) (3.03) (4.65) (0.9574) (0.9613) (1.6805)

Effective properties are based on a unit width of 1 000 mm (S.I. units) or 12 in. (imperial units).
Material according to ASTM A 653M SS Grade 230, yield strength of 230 MPa (33 ksi).
Tables are calculated according to CAN/CSA-S136-01 standard.

8
P-2436 & P-2404
FACTORED AND SERVICE LOADS TABLE (kPa) METRIC
Nominal SPAN (mm)
Type
Thickness (mm) 2 100 2 250 2 400 2 550 2 700 2 850 3 000 3 150 3 300 3 450 3 600 3 750 3 900
SINGLE SPAN
F 8.94 7.80 6.87 6.09 5.44 4.88 4.41 4.00
22 0.76
D 7.06 5.74 4.73 3.94 3.32 2.82 2.42 2.09
F 10.93 9.54 8.39 7.44 6.64 5.96 5.38 4.89 4.45 4.08
20 0.91
D 8.86 7.20 5.93 4.95 4.17 3.54 3.04 2.62 2.28 2.00
F 15.13 13.19 11.61 10.29 9.18 8.25 7.45 6.76 6.16 5.64 5.18 4.77 4.41
18 1.21
D 12.76 10.37 8.55 7.13 6.00 5.11 4.38 3.78 3.29 2.88 2.53 2.24 1.99
F 19.16 16.71 14.70 13.03 11.63 10.44 9.43 8.56 7.80 7.14 6.56 6.04 5.59
16 1.52
D 16.10 13.09 10.78 8.99 7.57 6.44 5.52 4.77 4.15 3.63 3.20 2.83 2.51
DOUBLE SPAN
F 9.42 8.23 7.25 6.44 5.75 5.17 4.67 4.24 3.87 3.54
22 0.76
D 17.00 13.82 11.39 9.50 8.00 6.80 5.83 5.04 4.38 3.83
F 11.51 10.04 8.84 7.85 7.01 6.30 5.69 5.16 4.71 4.31 3.96 3.65
20 0.91
D 21.33 17.34 14.29 11.91 10.04 8.53 7.32 6.32 5.50 4.81 4.23 3.75
F 15.43 13.46 11.85 10.51 9.38 8.43 7.61 6.91 6.30 5.77 5.30 4.88 4.52
18 1.21
D 30.74 24.99 20.59 17.17 14.46 12.30 10.54 9.11 7.92 6.93 6.10 5.40 4.80
F 19.14 16.70 14.70 13.04 11.64 10.46 9.44 8.57 7.81 7.15 6.57 6.06 5.60
16 1.52
D 38.78 31.53 25.98 21.66 18.24 15.51 13.30 11.49 9.99 8.74 7.70 6.81 6.05
TRIPLE SPAN
F (11.11) (10.18) 8.98 7.98 7.14 6.42 5.81 5.27 4.81 4.41 4.05 3.74
22 0.76
D 13.33 10.84 8.93 7.44 6.27 5.33 4.57 3.95 3.43 3.01 2.65 2.34
F 14.26 12.46 10.98 9.75 8.71 7.83 7.08 6.43 5.86 5.37 4.93 4.55 4.21
20 0.91
D 16.72 13.59 11.20 9.34 7.87 6.69 5.73 4.95 4.31 3.77 3.32 2.94 2.61
F 19.15 16.72 14.73 13.07 11.68 10.49 9.48 8.61 7.85 7.19 6.61 6.09 5.63
18 1.21
D 24.09 19.59 16.14 13.46 11.34 9.64 8.26 7.14 6.21 5.43 4.78 4.23 3.76
F 23.76 20.75 18.28 16.22 14.49 13.02 11.76 10.68 9.74 8.92 8.20 7.56 6.99
16 1.52
D 30.39 24.71 20.36 16.97 14.30 12.16 10.42 9.00 7.83 6.85 6.03 5.34 4.74

FACTORED AND SERVICE LOADS TABLE (psf) IMPERIAL


Nominal SPAN (ft.-in.)
Type
Thickness (in.) 7-0 7-6 8-0 8-6 9-0 9-6 10-0 10-6 11-0 11-6 12-0 12-6 13-0
SINGLE SPAN
F 181 158 139 123 110 99 89 81
22 0.030
D 141 114 94 79 66 56 48 42
F 221 193 170 151 134 121 109 99 90 82
20 0.036
D 176 143 118 98 83 71 60 52 45 40
F 306 267 235 208 186 167 151 137 125 114 105 97 89
18 0.048
D 254 207 170 142 120 102 87 75 65 57 50 45 40
F 388 338 297 264 235 211 191 173 158 144 133 122 113
16 0.060
D 321 261 215 179 151 128 110 95 83 72 64 56 50
DOUBLE SPAN
F 191 167 147 130 116 105 95 86 78
22 0.030
D 339 275 227 189 159 135 116 100 87
F 233 203 179 159 142 127 115 104 95 87 80 74
20 0.036
D 425 345 285 237 200 170 146 126 109 96 84 75
F 312 272 240 213 190 171 154 140 127 117 107 99 91
18 0.048
D 612 498 410 342 288 245 210 181 158 138 122 108 96
F 387 338 298 264 236 212 191 173 158 145 133 123 113
16 0.060
D 772 628 517 431 363 309 265 229 199 174 153 136 121
TRIPLE SPAN
F (236) 206 182 162 145 130 118 107 97 89 82 76
22 0.030
D 265 216 178 148 125 106 91 79 68 60 53 47
F 289 252 222 197 176 159 143 130 119 109 100 92 85
20 0.036
D 333 271 223 186 157 133 114 99 86 75 66 58 52
F 388 339 298 265 236 212 192 174 159 145 134 123 114
18 0.048
D 480 390 321 268 226 192 165 142 124 108 95 84 75
F 481 420 370 328 293 264 238 216 197 180 166 153 141
16 0.060
D 605 492 405 338 285 242 208 179 156 136 120 106 94

Loads in rows marked F are the maximum factored loads controlled Web crippling controls loads in brackets calculated with the end
by the bending capacity, and those in rows marked D are the uniform bearing length equal to 76 mm (3 in.) and the interior bearing length
service loads that produce a deflection of L/240. equal to 152 mm (6 in.). Refer to page 24 for web crippling tables
and examples.
Loads in rows marked F should be compared to factored loads
according to CAN/CSA-S16-01 Limit States Design of Steel Structure. The span is the shortest of the following dimensions: dimension c/c
of the supports, or the clear dimension between the supports plus the
The live loads producing deflection equal to the span/180 or span/360 depth of the deck at each end.
can be calculated by multiplying the loads in the D rows by 1.33 or
0.66 respectively.

9
P-3615 & P-3606 COMPOSITE
Canams composite P-3615 and P-3606 steel deck profiles are roll formed to cover 914 mm (36 in.).
The deck is available with a galvanized coating according to the standard
ASTM A 653M with zinc thickness corresponding
to Z275 (G90). Other types of steel sheet finishes
may affect the bond properties between
deck and concrete. Contact our
sales department for
more information.
Nominal thicknesses are
0.76 mm (0.030 in.),
0.91 mm (0.036 in.) and
1.21 mm (0.048 in.). The flutes
are 38 mm (1.5 in.) deep and are spaced at
152 mm (6 in.) center to center. The deck can be rolled
to lengths from 1 800 mm (6 ft.) to 12 200 mm (40 ft.). The narrow
flutes provide enough space to weld headed studs through the deck to
the top of beams or joists that will act in composite action with the concrete slab.
Standard steel grade conforms to ASTM A 653M SS Grade 230 with a yield
strength of 230 MPa (33 ksi). Steel grades up to 350 MPa (50 ksi) and
a material thickness of 1.07 mm (0.042 in.) are available
given sufficient delivery time.

DIMENSIONS
914 mm (36)

38 mm
(1 1/2)
64 mm 89 mm 38 mm 114 mm
P-3615 COMPOSITE (2 1/2) (3 1/2) (1 1/2) (4 1/2)
152 mm (6)

914 mm (36)

38 mm
(1 1/2)
64 mm 89 mm 38 mm 114 mm
P-3606 COMPOSITE (2 1/2) (3 1/2) (1 1/2) (4 1/2)
152 mm (6)

PHYSICAL PROPERTIES
Nominal Design Overall Section Modulus Moment Steel Center of
Type Weight
Thickness Thickness Depth M+ M of Inertia Area Gravity
mm mm mm kg/m2 mm 3 mm3 mm4 mm2 mm
(in.) (in.) (in.) (lb/ft2) 3
(in ) (in3) (in4) (in2) (in.)
0.76 0.762 37.4 8.50 9 529 10 081 202 228 1 016 22.50
22
(0.030) (0.0300) (1.47) (1.74) (0.1772) (0.1875) (0.1481) (0.480) (0.89)
0.91 0.909 37.5 10.07 11 558 12 005 254 750 1 212 22.58
20
(0.036) (0.0358) (1.48) (2.06) (0.2150) (0.2233) (0.1865) (0.573) (0.89)
1.21 1.217 37.8 13.26 15 813 15 994 363 493 1 622 22.73
18
(0.048) (0.0479) (1.49) (2.72) (0.2941) (0.2975) (0.2662) (0.766) (0.89)

Effective properties are based on a unit width of 1 000 mm (S.I. units) or 12 in. (imperial units).
Material according to ASTM A 653M SS Grade 230, yield strength of 230 MPa (33 ksi).
Tables are calculated according to CAN/CSA-S136-01 standard.

10
P-3615 & P-3606 COMPOSITE
FACTORED RESISTANCE TABLE OF COMPOSITE SLAB (kPa) METRIC
Slab Deck Maximum Unshored Span Self Comp. Mom. SPAN (mm)
Thick. Thick. Single Double Triple Weight of Inertia
(mm) (mm) (mm) (mm) (mm) (kPa) (106 mm4) 1 200 1 350 1 500 1 650 1 800 1 950 2 100 2 250 2 400 2 550 2 700 2 850 3 000
90
0.76 1 690 1 995 1 980 1.62 3.917 20.00 20.00 20.00 20.00 18.90 15.99 13.69 11.84 10.33 9.08 8.04 7.16 6.42
0.91 1 940 2 285 2 265 1.63 4.185 20.00 20.00 20.00 20.00 20.00 18.35 16.01 14.11 12.55 11.24 10.14 9.21 8.40
1.21 2 405 2 735 2 790 1.66 4.690 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.07 17.59 16.31 15.20 13.85
100
0.76 1 630 1 920 1 905 1.85 5.360 20.00 20.00 20.00 20.00 20.00 18.36 15.72 13.59 11.86 10.43 9.23 8.22 7.37
0.91 1 865 2 195 2 170 1.86 5.721 20.00 20.00 20.00 20.00 20.00 20.00 18.38 16.20 14.41 12.91 11.65 10.57 9.65
1.21 2 305 2 630 2 670 1.89 6.403 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 18.74 17.46 16.33
115
0.76 1 550 1 820 1 805 2.20 8.134 20.00 20.00 20.00 20.00 20.00 20.00 18.76 16.22 14.15 12.45 11.02 9.82 8.79
0.91 1 770 2 075 2 055 2.22 8.666 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.34 17.20 15.41 13.90 12.62 11.52
1.21 2 180 2 490 2 515 2.24 9.678 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.51
125
0.76 1 505 1 765 1 745 2.44 10.432 20.00 20.00 20.00 20.00 20.00 20.00 20.00 17.98 15.68 13.79 12.21 10.88 9.74
0.91 1 715 2 010 1 985 2.45 11.101 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.06 17.08 15.41 13.98 12.76
1.21 2 110 2 410 2 430 2.48 12.378 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00
140
0.76 1 440 1 690 1 670 2.79 14.627 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 17.98 15.81 14.00 12.47 11.17
0.91 1 640 1 920 1 895 2.81 15.535 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.58 17.66 16.03 14.63
1.21 2 010 2 300 2 315 2.83 17.278 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00
150
0.76 1 405 1 645 1 625 3.03 17.965 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.51 17.16 15.19 13.53 12.12
0.91 1 595 1 870 1 845 3.04 19.056 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.17 17.40 15.88
1.21 1 955 2 235 2 245 3.07 21.155 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00

The table is based on concrete density of 2 400 kg/m3 and mini- EXAMPLE
mum compressive resistance (fc ) equal to 20 MPa at 28 days.
Triple span of 1 800 mm, total slab thickness of 100 mm with 62 mm of
During construction, the steel deck must support itself, the concrete and concrete cover on top of 38 mm deck profile.
a construction uniform load of 1 kPa or a transverse load of 2 kN/m, as
specified by the Canadian Sheet Steel Building Institute. Once the concrete is cured, the composite slab will have to support these
loads:
The maximum unshored spans shown in the table are established for Dead load = 1.50 kPa
bending under the slab self-weight and the construction loads, for web
Service live load = 4.80 kPa
crippling and for the deflection under wet concrete to be less than the
span over 180 (L/180). The web crippling resistance is calculated According to the table of maximum unshored span above, we need to use
assuming the end bearing length equal to 40 mm and the interior a deck with a nominal thickness of 0.76 mm for a triple span condition.
bearing length equal to 102 mm.
Deck and concrete weights are 1.85 kPa (shown in the table).
If the bearing length is shorter, the design engineer must verify the Total factored load
web crippling factored resistance with the reaction produced by wet wf = 1.25 x (1.85 + 1.50) + 1.5 x 4.80 = 11.39 kPa
concrete and construction factored loads (refer to page 24 for web
crippling tables and examples). Factored resistance
wr = 20.00 kPa for a span of 1 800 mm, with a 100 mm slab and a 0.76 mm
Contact Canam sales personnel when the total uniform load exceeds thick deck.
20 kPa, as this is an indication that significant concentrated loads will
be used. The composite slab and its reinforcing should be verified for wr > wf OK
the effect of concentrated loads (see notes on page 5). Service load w = 4.80 kPa

Shaded values indicate that the deck should be shored at mid-span Composite moment of inertia is 5.360 x 106 mm4 (from the table).
during the pour and the curing of concrete for those spans and
5 w L4 5 x 4.80 x 1 8004
concrete thickness conditions. Shaded values correspond to the Deflection = =
maximum unshored span values shown at the left of the table. 384 Es Icomp 384 x 203 000 x 5 360 000

The design engineer is responsible for specifying size and location of = 0.6 mm <
1 800
= 5.0 mm OK
the wire mesh in the concrete slab in order to respect current concrete 360
practices.

11
P-3615 & P-3606 COMPOSITE
FACTORED RESISTANCE TABLE OF COMPOSITE SLAB (psf) IMPERIAL
Slab Deck Maximum Unshored Span Self Comp. Mom. SPAN (ft.-in.)
Thick. Thick. Single Double Triple Weight of Inertia
(in.) (in.) (ft.-in.) (ft.-in.) (ft.-in.) (psf) (in4) 4-0 4-6 5-0 5-6 6-0 6-6 7-0 7-6 8-0 8-6 9-0 9-6 10-0
3.50
0.030 5 - 6 6 - 7 6 - 6 33.2 2.789 420 420 420 420 376 318 272 235 205 180 160 142 127
0.036 6 - 4 7 - 6 7 - 5 33.5 2.979 420 420 420 420 420 366 319 282 250 224 203 184 168
0.048 7 - 11 9 - 0 9 - 2 34.1 3.338 420 420 420 420 420 420 420 418 384 354 328 306 278
4.00
0.030 5 - 3 6 - 3 6 - 2 39.5 4.150 420 420 420 420 420 379 324 280 244 215 190 169 152
0.036 6 - 1 7 - 1 7 - 1 39.8 4.428 420 420 420 420 420 420 381 336 298 267 241 219 200
0.048 7 - 6 8 - 6 8 - 8 40.3 4.953 420 420 420 420 420 420 420 420 420 420 391 365 341
4.50
0.030 5 - 1 5 - 11 5 - 11 45.8 5.899 420 420 420 420 420 420 376 325 284 249 221 197 176
0.036 5 - 9 6 - 10 6 - 9 46.0 6.284 420 420 420 420 420 420 420 389 346 310 280 254 232
0.048 7 - 2 8 - 2 8 - 3 46.6 7.016 420 420 420 420 420 420 420 420 420 420 420 420 396
5.00
0.030 4 -10 5 - 9 5 - 8 52.0 8.079 420 420 420 420 420 420 420 370 323 284 251 224 200
0.036 5 - 7 6 - 6 6 - 5 52.3 8.593 420 420 420 420 420 420 420 420 394 353 319 289 264
0.048 6 -10 7 - 10 7 -10 52.8 9.575 420 420 420 420 420 420 420 420 420 420 420 420 420
5.50
0.030 4 - 8 5 - 6 5 - 5 58.3 10.737 420 420 420 420 420 420 420 415 362 318 282 251 225
0.036 5 - 4 6 - 3 6 - 2 58.5 11.401 420 420 420 420 420 420 420 420 420 396 358 325 296
0.048 6 - 7 7 - 6 7 - 7 59.1 12.675 420 420 420 420 420 420 420 420 420 420 420 420 420
6.00
0.030 4 - 7 5 - 4 5 - 3 64.5 13.916 420 420 420 420 420 420 420 420 401 353 312 278 249
0.036 5 - 2 6 - 1 6 - 0 64.8 14.752 420 420 420 420 420 420 420 420 420 420 396 360 328
0.048 6 - 4 7 - 3 7 - 3 65.3 16.363 420 420 420 420 420 420 420 420 420 420 420 420 420

The table is based on concrete density of 150 lb/ft3 and minimum EXAMPLE
compressive resistance (fc ) equal to 3 000 psi at 28 days.
Triple span of 6-0, total slab thickness of 4 with 2 1/2 of concrete cover
During construction, the steel deck must support itself, the concrete and on top of 1 1/2 deck profile.
a construction uniform load of 21 psf or a transverse load of 137 plf as
specified by the Canadian Sheet Steel Building Institute. Once the concrete is cured, the composite slab will have to support these
loads:
The maximum unshored spans shown in the table are established for Dead load = 30 psf
bending under the slab self-weight and the construction loads, for web
Service live load = 100 psf
crippling and for the deflection under wet concrete to be less than the
span over 180 (L/180). The web crippling resistance is calculated According to the table of maximum unshored span above, we need to use
assuming the end bearing length equal to 1.5 in. and the interior a deck with a nominal thickness of 0.030 for a triple span condition.
bearing length equal to 4 in.
Deck and concrete weights are 39.5 psf (shown in the table).
If the bearing length is shorter, the design engineer must verify the Total factored load
web crippling factored resistance with the reaction produced by wet wf = 1.25 x (39.5 + 30) + 1.5 x 100 = 237 psf
concrete and construction factored loads (refer to page 24 for web
crippling tables and examples). Factored resistance
wr = 420 psf for a span of 6-0, with a 4 slab and a 0.030 thick deck.
Contact Canam sales personnel when the total uniform load exceeds wr > wf OK
420 psf, as this is an indication that significant concentrated loads will
be used. The composite slab and its reinforcing should be verified for Service load w = 100 psf
the effect of concentrated loads (see notes on page 5).
Composite moment of inertia is 4.150 in4 (from the table).
Shaded values indicate that the deck should be shored at mid-span
5 w L4 5 x 100 x 64 x 1 728
during the pour and the curing of concrete for those spans and Deflection = =
concrete thickness conditions. Shaded values correspond to the 384 Es Icomp 384 x 29 500 x 4.150 x 1 000
maximum unshored span values shown at the left of the table.
72
The design engineer is responsible for specifying size and location of = 0.02 < = 0.20 OK
the wire mesh in the concrete slab in order to respect current 360
concrete practices.

12
P-3615 & P-3606 COMPOSITE
FACTORED RESISTANCE TABLE OF COMPOSITE SLAB (kPa) LIGHTWEIGHT CONCRETE - METRIC
Slab Deck Maximum Unshored Span Self Comp. Mom. SPAN (mm)
Thick. Thick. Single Double Triple Weight of Inertia
(mm) (mm) (mm) (mm) (mm) (kPa) (106 mm4) 1 200 1 350 1 500 1 650 1 800 1 950 2 100 2 250 2 400 2 550 2 700 2 850 3 000
100
0.76 1 740 2 060 2 045 1.44 4.398 20.00 20.00 20.00 20.00 20.00 18.36 15.72 13.59 11.86 10.43 9.23 8.22 7.37
0.91 2 005 2 365 2 345 1.45 4.717 20.00 20.00 20.00 20.00 20.00 20.00 18.38 16.20 14.41 12.91 11.65 10.57 9.65
1.21 2 490 2 825 2 895 1.48 5.312 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 18.74 17.46 16.33
115
0.76 1 665 1 965 1 950 1.71 6.652 20.00 20.00 20.00 20.00 20.00 20.00 18.76 16.22 14.15 12.45 11.02 9.82 8.79
0.91 1 910 2 245 2 225 1.72 7.127 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.34 17.20 15.41 13.90 12.62 11.52
1.21 2 365 2 690 2 740 1.75 8.016 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.51
125
0.76 1 620 1 910 1 890 1.89 8.513 20.00 20.00 20.00 20.00 20.00 20.00 20.00 17.98 15.68 13.79 12.21 10.88 9.74
0.91 1 855 2 180 2 155 1.90 9.112 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.06 17.08 15.41 13.98 12.76
1.21 2 290 2 610 2 650 1.93 10.238 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00
140
0.76 1 560 1 835 1 815 2.16 11.895 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 17.98 15.81 14.00 12.47 11.17
0.91 1 780 2 090 2 065 2.17 12.713 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.58 17.66 16.03 14.63
1.21 2 195 2 505 2 530 2.20 14.260 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00
150
0.76 1 520 1 790 1 770 2.34 14.575 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.51 17.16 15.19 13.53 12.12
0.91 1 735 2 035 2 015 2.36 15.561 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.17 17.40 15.88
1.21 2 135 2 440 2 460 2.38 17.432 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00
165
0.76 1 470 1 725 1 710 2.61 19.287 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.17 16.97 15.12 13.54
0.91 1 675 1 965 1 940 2.63 20.558 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.45 17.75
1.21 2 060 2 355 2 370 2.65 22.983 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00
The table is based on concrete density of 1 840 kg/m3 and minimum compressive resistance (fc ) equal to 25 MPa at 28 days.
Refer to page 11 for other notes.
FACTORED RESISTANCE TABLE OF COMPOSITE SLAB (psf) LIGHTWEIGHT CONCRETE - IMPERIAL
Slab Deck Maximum Unshored Span Self Comp. Mom. SPAN (ft.-in.)
Thick. Thick. Single Double Triple Weight of Inertia
(in.) (in.) (ft.-in.) (ft.-in.) (ft.-in.) (psf) (in4) 4-0 4-6 5-0 5-6 6-0 6-6 7-0 7-6 8-0 8-6 9-0 9-6 10-0
4.00
0.030 5 - 8 6 - 8 6 - 8 30.7 3.451 420 420 420 420 420 379 324 280 244 215 190 169 152
0.036 6 - 6 7 - 8 7 - 7 31.0 3.699 420 420 420 420 420 420 381 336 298 267 241 219 200
0.048 8 - 1 9 - 2 9 - 5 31.6 4.163 420 420 420 420 420 420 420 420 420 420 391 365 341
4.50
0.030 5 - 5 6 - 5 6 - 4 35.5 4.892 420 420 420 420 420 420 376 325 284 249 221 197 176
0.036 6 - 3 7 - 4 7 - 3 35.8 5.239 420 420 420 420 420 420 420 389 346 310 280 254 232
0.048 7 - 9 8 -10 9 - 0 36.3 5.889 420 420 420 420 420 420 420 420 420 420 420 420 396
5.00
0.030 5 - 3 6 - 2 6 - 2 40.3 6.683 420 420 420 420 420 420 420 370 323 284 251 224 200
0.036 6 - 0 7 - 1 7 - 0 40.6 7.147 420 420 420 420 420 420 420 420 394 353 319 289 264
0.048 7 - 5 8 - 6 8 - 7 41.1 8.024 420 420 420 420 420 420 420 420 420 420 420 420 420
5.50
0.030 5 - 1 6 - 0 5 - 11 45.1 8.857 420 420 420 420 420 420 420 415 362 318 282 251 225
0.036 5 -10 6 -10 6 - 9 45.4 9.460 420 420 420 420 420 420 420 420 420 396 358 325 296
0.048 7 - 2 8 - 2 8 - 3 45.9 10.603 420 420 420 420 420 420 420 420 420 420 420 420 420
6.00
0.030 4 - 11 5 -10 5 - 9 49.9 11.447 420 420 420 420 420 420 420 420 401 353 312 278 249
0.036 5 - 8 6 - 7 6 - 6 50.1 12.209 420 420 420 420 420 420 420 420 420 420 396 360 328
0.048 6 - 11 7 -11 8 - 0 50.7 13.661 420 420 420 420 420 420 420 420 420 420 420 420 420
6.50
0.030 4 - 9 5 - 8 5 - 7 54.7 14.487 420 420 420 420 420 420 420 420 420 387 343 305 274
0.036 5 - 6 6 - 5 6 - 4 54.9 15.430 420 420 420 420 420 420 420 420 420 420 420 395 361
0.048 6 - 9 7 - 8 7 - 9 55.5 17.233 420 420 420 420 420 420 420 420 420 420 420 420 420

The table is based on concrete density of 115 lb/ft3 and minimum compressive resistance (fc ) equal to 4 000 psi at 28 days.
Refer to page 12 for other notes.

13
P-3623 COMPOSITE
Canams composite P-3623 is a steel deck roll formed to cover 914 mm (36 in.).
The deck is available with a galvanized coating according to the standard ASTM A 653M with
zinc thickness corresponding to Z275 (G90). Other types of steel sheet
finishes may affect the bond properties between deck
and concrete. Venting slots can be added to the
bottom of the flutes. Contact our sales
department for more information.
Nominal thickness are 0.76 mm
(0.030 in.), 0.91 mm (0.036 in.)
and 1.21 mm (0.048 in.).
The flutes are
51 mm (2 in.) deep
and are spaced at 305 mm (12 in.)
center to center. The deck can be rolled to
lengths from 1 800 mm (6 ft.) to 12 200 mm (40 ft.).
The wide flutes provide enough space to
weld headed studs through the deck to the top
of beams or joists that will act in composite action with the concrete slab.
Standard steel grade conforms to ASTM A 653M SS Grade 230 with a yield strength
of 230 MPa (33 ksi). Steel grades up to 350 MPa (50 ksi) and material
thickness of 1.07 mm (0.042 in.) are available given sufficient delivery time.
DIMENSIONS

914 mm (36)

51 mm
(2)
140 mm
P-3623 (5 1/2)
COMPOSITE 305 mm
(12)

165 mm 140 mm
(6 1/2) (5 1/2)

PHYSICAL PROPERTIES
Nominal Design Overall Section Modulus Moment Steel Center of
Type Weight
Thickness Thickness Depth M+ M of Inertia Area Gravity
mm mm mm kg/m2 mm 3 mm3 mm4 mm2 mm
(in.) (in.) (in.) (lb/ft2) 3
(in ) (in3) (in4) (in2) (in.)
0.76 0.762 50.8 8.50 15 350 15 350 430 932 1 016 25.40
22
(0.030) (0.0300) (2.00) (1.74) (0.2855) (0.2855) (0.3156) (0.480) (1.00)
0.91 0.909 51.0 10.07 19 473 19 473 532 353 1 212 25.47
20
(0.036) (0.0358) (2.01) (2.06) (0.3622) (0.3622) (0.3898) (0.573) (1.00)
1.21 1.217 51.3 13.26 27 996 27 996 717 655 1 622 25.63
18
(0.048) (0.0479) (2.02) (2.72) (0.5207) (0.5207) (0.5255) (0.766) (1.01)

Effective properties are based on a unit width of 1 000 mm (S.I. units) or 12 in. (imperial units).
Material according to ASTM A 653M SS Grade 230, yield strength of 230 MPa (33 ksi).
Tables are calculated according to CAN/CSA-S136-01 standard.

14
P-3623 COMPOSITE
FACTORED RESISTANCE TABLE OF COMPOSITE SLAB (kPa) METRIC
Slab Deck Maximum Unshored Span Self Comp. Mom. SPAN (mm)
Thick. Thick. Single Double Triple Weight of Inertia
(mm) (mm) (mm) (mm) (mm) (kPa) (106 mm4) 1 500 1 650 1 800 1 950 2 100 2 250 2 400 2 550 2 700 2 850 3 000 3 150 3 300
100
0.76 2 280 2 430 2 530 1.84 5.718 20.00 18.78 16.05 13.91 12.20 10.80 9.65 8.68 7.87 7.17 6.57 6.05 5.59
0.91 2 670 2 920 3 015 1.85 6.080 20.00 20.00 20.00 17.40 15.25 13.50 12.05 10.84 9.82 8.94 8.19 7.54 6.97
1.21 3 115 3 485 3 575 1.88 6.772 20.00 20.00 20.00 20.00 18.28 16.17 14.44 12.98 11.75 10.71 9.80 9.02 8.34
125
0.76 2 035 2 035 2 120 2.43 10.841 20.00 20.00 20.00 18.58 16.29 14.42 12.88 11.59 10.51 9.58 8.77 8.08 7.47
0.91 2 425 2 675 2 765 2.44 11.498 20.00 20.00 20.00 20.00 20.00 18.02 16.09 14.48 13.11 11.94 10.94 10.07 9.31
1.21 2 845 3 195 3 265 2.47 12.758 20.00 20.00 20.00 20.00 20.00 20.00 19.29 17.35 15.71 14.31 13.10 12.05 11.14
140
0.76 1 855 1 855 1 930 2.78 15.050 20.00 20.00 20.00 20.00 18.74 16.59 14.82 13.34 12.09 11.02 10.10 9.29 8.59
0.91 2 310 2 550 2 640 2.80 15.938 20.00 20.00 20.00 20.00 20.00 20.00 18.52 16.66 15.09 13.74 12.59 11.59 10.71
1.21 2 720 3 050 3 125 2.82 17.647 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.96 18.08 16.46 15.08 13.87 12.82
150
0.76 1 750 1 750 1 825 3.02 18.390 20.00 20.00 20.00 20.00 20.00 18.04 16.12 14.51 13.14 11.98 10.98 10.11 9.34
0.91 2 245 2 420 2 525 3.03 19.456 20.00 20.00 20.00 20.00 20.00 20.00 20.00 18.11 16.40 14.94 13.69 12.60 11.64
1.21 2 650 2 965 3 040 3.06 21.511 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.66 17.90 16.39 15.08 13.94
165
0.76 1 615 1 615 1 685 3.37 24.277 20.00 20.00 20.00 20.00 20.00 20.00 18.06 16.25 14.72 13.42 12.30 11.32 10.47
0.91 2 155 2 235 2 330 3.38 25.643 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 18.38 16.74 15.34 14.11 13.05
1.21 2 555 2 850 2 930 3.41 28.288 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 18.37 16.90 15.62
190
0.76 1 430 1 430 1 395 3.96 36.664 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.16 17.36 15.82 14.50 13.35 12.34
0.91 1 980 1 980 2 065 3.97 38.628 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.74 18.08 16.64 15.38
1.21 2 425 2 680 2 770 4.00 42.447 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.94 18.42

The table is based on concrete density of 2 400 kg/m3 and mini- EXAMPLE
mum compressive resistance (fc ) equal to 20 MPa at 28 days.
Triple span of 2 400 mm, total slab thickness of 125 mm with 74 mm of
During construction, the steel deck must support itself, the concrete and concrete cover on top of 51 mm deck profile.
a construction uniform load of 1 kPa or a transverse load of 2 kN/m as
specified by the Canadian Sheet Steel Building Institute. Once the concrete is cured, the composite slab will have to support these
loads:
The maximum unshored spans shown in the table are established for Dead load = 1.50 kPa
bending under the slab self-weight and the construction loads, for web Service live load = 4.80 kPa
crippling and for the deflection under wet concrete to be less than the
span over 180 (L/180). The web crippling resistance is calculated According to the table of maximum unshored span above, we need to use
assuming the end bearing length equal to 51 mm and the interior a deck with a nominal thickness of 0.91 mm for a triple span condition.
bearing length equal to 127 mm. Deck and concrete weight is 2.44 kPa (shown in the table).
If the bearing length is shorter, the design engineer must verify the Total factored load
web crippling factored resistance with the reaction produced by wet wf = 1.25 x (2.44 + 1.50) + 1.5 x 4.80 = 12.13 kPa
concrete and construction factored loads (refer to page 24 for web
Factored resistance
crippling tables and examples).
wr = 16.09 kPa for a span of 2 400 mm, with a 125 mm slab and a 0.91 mm
Contact Canam sales personnel when the total uniform load exceeds thick deck.
20 kPa, as this is an indication that significant concentrated loads will
wr > wf OK
be used. The composite slab and its reinforcing should be verified for
the effect of concentrated loads (see notes on page 5). Service load w = 4.80 kPa
Composite moment of inertia is 11.498 x 106 mm4 (from the table).
Shaded values indicate that the deck should be shored at mid-span
during the pour and the curing of concrete for those spans and 5 w L4 5 x 4.80 x 2 4004
concrete thickness conditions. Shaded values correspond to the Deflection = =
maximum unshored span values shown at the left of the table. 384 Es Icomp 384 x 203 000 x 11 498 000

The design engineer is responsible for specifying size and location = 0.9 mm <
2 400
= 6.7 mm OK
of the wire mesh in the concrete slab in order to respect current
360
concrete practices.

15
P-3623 COMPOSITE
FACTORED RESISTANCE TABLE OF COMPOSITE SLAB (psf) IMPERIAL
Slab Deck Maximum Unshored Span Self Comp. Mom. SPAN (ft.-in.)
Thick. Thick. Single Double Triple Weight of Inertia
(in.) (in.) (ft.-in.) (ft.-in.) (ft.-in.) (psf) (in4) 5-0 5-6 6-0 6-6 7-0 7-6 8-0 8-6 9-0 9-6 10-0 10-6 11-0
4.00
0.030 7 - 5 7 -10 8 - 2 39.3 4.419 420 389 333 289 253 224 200 180 163 149 136 126 116
0.036 8 - 8 9 - 6 9 -10 39.5 4.697 420 420 416 361 316 280 250 225 204 186 170 157 145
0.048 10 - 1 11 - 4 11 - 7 40.1 5.227 420 420 420 420 379 335 299 269 244 222 204 187 173
5.00
0.030 6 - 7 6 - 7 6 -10 51.8 8.385 420 420 420 385 337 299 267 240 218 199 182 168 155
0.036 7 -10 8 - 8 9 - 0 52.0 8.889 420 420 420 420 420 373 333 300 272 248 227 209 193
0.048 9 - 3 10 - 4 10 - 7 52.6 9.857 420 420 420 420 420 420 400 359 326 297 272 250 231
5.50
0.030 6 - 1 6 - 1 6 - 4 58.0 11.052 420 420 420 420 380 336 300 270 245 223 205 189 174
0.036 7 - 7 8 - 4 8 - 7 58.3 11.701 420 420 420 420 420 420 375 338 306 279 255 235 217
0.048 8 -11 10 - 0 10 - 3 58.9 12.951 420 420 420 420 420 420 420 405 366 334 306 281 260
6.00
0.030 5 - 8 5 - 8 5 -10 64.3 14.233 420 420 420 420 420 374 334 300 272 248 227 209 194
0.036 7 - 3 7 -10 8 - 2 64.5 15.050 420 420 420 420 420 420 417 375 340 310 284 261 241
0.048 8 - 7 9 - 7 9 -11 65.1 16.626 420 420 420 420 420 420 420 420 407 371 340 313 289
6.50
0.030 5 - 3 5 - 3 5 - 6 70.5 17.974 420 420 420 420 420 411 367 330 299 273 250 230 213
0.036 7 - 0 7 - 3 7 - 7 70.8 18.980 420 420 420 420 420 420 420 413 374 341 312 287 265
0.048 8 - 4 9 - 4 9 - 7 71.4 20.927 420 420 420 420 420 420 420 420 420 408 374 344 318
7.50
0.030 4 - 8 4 - 8 4 -10 83.0 27.312 420 420 420 420 420 420 420 391 354 323 296 272 252
0.036 6 - 5 6 - 5 6 - 9 83.3 28.765 420 420 420 420 420 420 420 420 420 403 369 339 314
0.048 7 -11 8 - 9 9 - 1 83.9 31.591 420 420 420 420 420 420 420 420 420 420 420 407 376

The table is based on concrete density of 150 lb/ft3 and minimum EXAMPLE
compressive resistance (fc ) equal to 3 000 psi at 28 days.
Triple span of 8-0, total slab thickness of 5 with 3 of concrete cover on
During construction, the steel deck must support itself, the concrete and top of 2 deck profile.
a construction uniform load of 21 psf or a transverse load of 137 plf as
specified by the Canadian Sheet Steel Building Institute. Once the concrete is cured, the composite slab will have to support these
loads:
The maximum unshored spans shown in the table are established for Dead load = 30 psf
bending under the slab self-weight and the construction loads, for web Service live load = 100 psf
crippling and for the deflection under wet concrete to be less than the
span over 180 (L/180). The web crippling resistance is calculated According to the table of maximum unshored span above, we need to use
assuming the end bearing length equal to 2 in. and the interior a deck with a nominal thickness of 0.036 for a triple span condition.
bearing length equal to 5 in. Deck and concrete weight is 52.0 psf (shown in the table).
If the bearing length is shorter, the design engineer must verify the Total factored load
web crippling factored resistance with the reaction produced by wet wf = 1.25 x (52.0 + 30) + 1.5 x 100 = 253 psf
concrete and construction factored loads (refer to page 24 for web
Factored resistance
crippling tables and examples).
wr = 333 psf for a span of 8-0, with a 5 slab and a 0.036 thick deck.
Contact Canam sales personnel when the total uniform load exceeds wr > wf OK
420 psf, as this is an indication that significant concentrated loads will
be used. The composite slab and its reinforcing should be verified for Service load w = 100 psf
the effect of concentrated loads (see notes on page 5). Composite moment of inertia is 8.889 in4 (from the table).
Shaded values indicate that the deck should be shored at mid-span 5 w L4 5 x 100 x 8.04 x 1 728
during the pour and the curing of concrete for those spans and Deflection = =
concrete thickness conditions. Shaded values correspond to the 384 Es Icomp 384 x 29 500 x 8.889 x 1 000
maximum unshored span values shown at the left of the table.
96
The design engineer is responsible for specifying size and location = 0.04 <
360
= 0.27 OK
of the wire mesh in the concrete slab in order to respect current
concrete practices.

16
P-3623 COMPOSITE
FACTORED RESISTANCE TABLE OF COMPOSITE SLAB (kPa) LIGHTWEIGHT CONCRETE - METRIC
Slab Deck Maximum Unshored Span Self Comp. Mom. SPAN (mm)
Thick. Thick. Single Double Triple Weight of Inertia
(mm) (mm) (mm) (mm) (mm) (kPa) (106 mm4) 1 500 1 650 1 800 1 950 2 100 2 250 2 400 2 550 2 700 2 850 3 000 3 150 3 300
115
0.76 2 335 2 545 2 655 1.70 6.925 20.00 20.00 19.28 16.71 14.65 12.97 11.59 10.43 9.45 8.61 7.89 7.27 6.72
0.91 2 740 2 990 3 090 1.71 7.396 20.00 20.00 20.00 20.00 18.32 16.21 14.47 13.02 11.79 10.74 9.84 9.06 8.37
1.21 3 195 3 565 3 670 1.74 8.287 20.00 20.00 20.00 20.00 20.00 19.43 17.35 15.60 14.13 12.87 11.78 10.84 10.02
125
0.76 2 265 2 400 2 500 1.88 8.788 20.00 20.00 20.00 18.58 16.29 14.42 12.88 11.59 10.51 9.58 8.77 8.08 7.47
0.91 2 650 2 900 2 995 1.90 9.379 20.00 20.00 20.00 20.00 20.00 18.02 16.09 14.48 13.11 11.94 10.94 10.07 9.31
1.21 3 095 3 460 3 550 1.92 10.497 20.00 20.00 20.00 20.00 20.00 20.00 19.29 17.35 15.71 14.31 13.10 12.05 11.14
140
0.76 2 165 2 205 2 295 2.15 12.167 20.00 20.00 20.00 20.00 18.74 16.59 14.82 13.34 12.09 11.02 10.10 9.29 8.59
0.91 2 530 2 780 2 875 2.17 12.968 20.00 20.00 20.00 20.00 20.00 20.00 18.52 16.66 15.09 13.74 12.59 11.59 10.71
1.21 2 960 3 320 3 395 2.19 14.491 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.96 18.08 16.46 15.08 13.87 12.82
150
0.76 2 090 2 090 2 180 2.33 14.840 20.00 20.00 20.00 20.00 20.00 18.04 16.12 14.51 13.14 11.98 10.98 10.11 9.34
0.91 2 460 2 710 2 800 2.35 15.804 20.00 20.00 20.00 20.00 20.00 20.00 20.00 18.11 16.40 14.94 13.69 12.60 11.64
1.21 2 885 3 235 3 310 2.37 17.640 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.66 17.90 16.39 15.08 13.94
165
0.76 1 940 1 940 2 025 2.60 19.534 20.00 20.00 20.00 20.00 20.00 20.00 18.06 16.25 14.72 13.42 12.30 11.32 10.47
0.91 2 365 2 610 2 700 2.62 20.776 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 18.38 16.74 15.34 14.11 13.05
1.21 2 780 3 120 3 190 2.65 23.149 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 18.37 16.90 15.62
190
0.76 1 735 1 735 1 810 3.05 29.363 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.16 17.36 15.82 14.50 13.35 12.34
0.91 2 235 2 400 2 500 3.07 31.158 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.74 18.08 16.64 15.38
1.21 2 640 2 950 3 030 3.10 34.610 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.94 18.42
The table is based on concrete density of 1 840 kg/m3 and minimum compressive resistance (fc) equal to 25 MPa at 28 days.
Refer to page 15 for other notes.
FACTORED RESISTANCE TABLE OF COMPOSITE SLAB (psf) LIGHTWEIGHT CONCRETE - IMPERIAL
Slab Deck Maximum Unshored Span Self Comp. Mom. SPAN (ft.-in.)
Thick. Thick. Single Double Triple Weight of Inertia
(in.) (in.) (ft.-in.) (ft.-in.) (ft.-in.) (psf) (in4) 5-0 5-6 6-0 6-6 7-0 7-6 8-0 8-6 9-0 9-6 10-0 10-6 11-0
4.50
0.030 7 - 8 8 - 4 8 - 8 35.3 5.100 420 420 388 337 295 261 234 210 191 174 159 147 136
0.036 9 - 0 9 - 9 10 - 1 35.6 5.444 420 420 420 420 369 327 292 262 238 217 198 183 169
0.048 10 - 6 11 - 8 12 - 0 36.2 6.095 420 420 420 420 420 392 350 314 285 259 238 219 202
5.00
0.030 7 - 4 7 - 9 8 - 1 40.1 6.894 420 420 420 385 337 299 267 240 218 199 182 168 155
0.036 8 - 7 9 - 5 9 - 9 40.4 7.351 420 420 420 420 420 373 333 300 272 248 227 209 193
0.048 10 - 1 11 - 3 11 - 6 41.0 8.219 420 420 420 420 420 420 400 359 326 297 272 250 231
5.50
0.030 7 - 1 7 - 2 7 - 6 44.9 9.066 420 420 420 420 380 336 300 270 245 223 205 189 174
0.036 8 - 3 9 - 1 9 - 5 45.2 9.657 420 420 420 420 420 420 375 338 306 279 255 235 217
0.048 9 - 8 10 -10 11 - 1 45.8 10.781 420 420 420 420 420 420 420 405 366 334 306 281 260
6.00
0.030 6 - 9 6 - 9 7 - 0 49.7 11.650 420 420 420 420 420 374 334 300 272 248 227 209 194
0.036 8 - 0 8 -10 9 - 1 50.0 12.396 420 420 420 420 420 420 417 375 340 310 284 261 241
0.048 9 - 4 10 - 6 10 - 9 50.6 13.819 420 420 420 420 420 420 420 420 407 371 340 313 289
6.50
0.030 6 - 4 6 - 4 6 - 7 54.5 14.679 420 420 420 420 420 411 367 330 299 273 250 230 213
0.036 7 - 9 8 - 6 8 -10 54.8 15.601 420 420 420 420 420 420 420 413 374 341 312 287 265
0.048 9 - 1 10 - 2 10 - 5 55.4 17.365 420 420 420 420 420 420 420 420 420 408 374 344 318
7.50
0.030 5 - 8 5 - 8 5 -11 64.1 22.206 420 420 420 420 420 420 420 391 354 323 296 272 252
0.036 7 - 3 7 -10 8 - 2 64.3 23.545 420 420 420 420 420 420 420 420 420 403 369 339 314
0.048 8 - 7 9 - 8 9 -11 64.9 26.122 420 420 420 420 420 420 420 420 420 420 420 407 376

The table is based on concrete density of 115 lb/ft3 and minimum compressive resistance (fc) equal to 4 000 psi at 28 days.
Refer to page 16 for other notes.

17
P-2432 COMPOSITE
Canams composite P-2432 is a steel deck roll formed to cover 610 mm (24 in.).
The deck is available with a galvanized coating according to the
standard ASTM A 653M with zinc thickness corresponding
to Z275 (G90). Other types of steel sheet finishes may
affect the bond properties between deck and concrete.
Venting slots can be added to the bottom of the flutes.
Contact our sales department for more information.
Nominal thicknesses are 0.76 mm
(0.030 in.), 0.91 mm (0.036 in.)
and 1.21 mm (0.048 in.). The
flutes are 76 mm (3 in.) deep
and are spaced at 305 mm
(12 in.) center to center.
The deck can be rolled to lengths
from 1 800 mm (6 ft.) to 12 200 mm (40 ft.).
The wide flutes provide enough space to weld
headed studs through the deck to the top of beams or
joists that will act in composite action with the concrete slab.
Standard steel grade conforms to ASTM A 653M SS Grade 230 with a yield
strength of 230 MPa (33 ksi). Steel grades up to 350 MPa (50 ksi) and material
thickness of 1.07 mm (0.042 in.) are available given sufficient delivery time.

DIMENSIONS

610 mm (24)

76 mm
(3)
135 mm
(5 5/16)
P-2432 305 mm
COMPOSITE (12)
164 mm 141 mm
(6 7/16) (5 9/16)

PHYSICAL PROPERTIES
Nominal Design Overall Section Modulus Moment Steel Center of
Type Weight
Thickness Thickness Depth M+ M of Inertia Area Gravity
mm mm mm kg/m2 mm 3 mm3 mm4 mm2 mm
(in.) (in.) (in.) (lb/ft2) (in3) (in3) (in4) (in2) (in.)
0.76 0.762 76.2 9.46 24 496 24 528 1 065 293 1 131 37.51
22
(0.030) (0.0300) (3.00) (1.94) (0.4556) (0.4562) (0.7801) (0.534) (1.48)
0.91 0.909 76.4 11.21 31 156 31 273 1 320 131 1 350 37.59
20
(0.036) (0.0358) (3.01) (2.30) (0.5795) (0.5817) (0.9667) (0.638) (1.48)
1.21 1.217 76.7 14.71 45 921 46 310 1 813 851 1 800 37.74
18
(0.048) (0.0479) (3.02) (3.01) (0.8541) (0.8614) (1.3283) (0.850) (1.49)

Effective properties are based on a unit width of 1 000 mm (S.I. units) or 12 in. (imperial units).
Material according to ASTM A 653M SS Grade 230, yield strength of 230 MPa (33 ksi).
Tables are calculated according to CAN/CSA-S136-01 standard.

18
P-2432 COMPOSITE
FACTORED RESISTANCE TABLE OF COMPOSITE SLAB (kPa) METRIC
Slab Deck Maximum Unshored Span Self Comp. Mom. SPAN (mm)
Thick. Thick. Single Double Triple Weight of Inertia
(mm) (mm) (mm) (mm) (mm) (kPa) (106 mm4) 2 100 2 250 2400 2 550 2 700 2 850 3 000 3 150 3 300 3 450 3 600 3 750 3 900
125
0.76 2 455 2 455 2 555 2.14 10.569 17.78 15.48 13.61 12.06 10.75 9.65 8.71 7.90 7.20 6.59 6.05 5.57 5.15
0.91 3 375 3 375 3 515 2.15 11.200 20.00 17.76 15.75 14.07 12.66 11.46 10.43 9.55 8.77 8.09 7.49 6.96 6.49
1.21 4 040 4 275 4 420 2.18 12.413 20.00 20.00 20.00 19.68 17.97 16.50 15.22 14.11 13.13 12.27 11.50 10.81 10.20
140
0.76 2 220 2 220 2 310 2.49 14.566 20.00 18.14 15.94 14.12 12.60 11.31 10.20 9.25 8.43 7.72 7.09 6.53 6.04
0.91 3 050 3 050 3 180 2.51 15.410 20.00 20.00 18.45 16.49 14.83 13.43 12.23 11.18 10.28 9.48 8.78 8.16 7.61
1.21 3 845 4 070 4 205 2.54 17.026 20.00 20.00 20.00 20.00 20.00 19.33 17.84 16.54 15.39 14.38 13.48 12.67 11.95
150
0.76 2 085 2 085 2 170 2.73 17.731 20.00 19.91 17.50 15.50 13.83 12.41 11.20 10.16 9.26 8.47 7.78 7.17 6.63
0.91 2 870 2 870 2 990 2.74 18.742 20.00 20.00 20.00 18.10 16.28 14.74 13.42 12.28 11.28 10.41 9.64 8.96 8.35
1.21 3 730 3 945 4 080 2.77 20.676 20.00 20.00 20.00 20.00 20.00 20.00 19.58 18.15 16.90 15.79 14.80 13.91 13.12
165
0.76 1 915 1 915 1 995 3.08 23.305 20.00 20.00 19.83 17.57 15.67 14.06 12.69 11.51 10.49 9.60 8.81 8.12 7.51
0.91 2 635 2 635 2 745 3.10 24.605 20.00 20.00 20.00 20.00 18.46 16.71 15.21 13.91 12.79 11.80 10.92 10.15 9.46
1.21 3 585 3 785 3 910 3.13 27.092 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.16 17.90 16.77 15.77 14.87
190
0.76 1 680 1 680 1 750 3.67 35.048 20.00 20.00 20.00 20.00 18.74 16.82 15.18 13.77 12.55 11.48 10.54 9.72 8.98
0.91 2 315 2 315 2 410 3.68 36.933 20.00 20.00 20.00 20.00 20.00 19.99 18.19 16.64 15.29 14.11 13.07 12.14 11.32
1.21 3 385 3 550 3 670 3.71 40.548 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 18.87 17.79
200
0.76 1 605 1 605 1 670 3.90 40.689 20.00 20.00 20.00 20.00 19.97 17.92 16.18 14.67 13.37 12.23 11.23 10.35 9.57
0.91 2 210 2 210 2 300 3.92 42.845 20.00 20.00 20.00 20.00 20.00 20.00 19.39 17.74 16.30 15.04 13.92 12.94 12.06
1.21 3 315 3 465 3 585 3.95 46.985 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 18.96

The table is based on concrete density of 2 400 kg/m3 and mini- EXAMPLE
mum compressive resistance (fc ) equal to 20 MPa at 28 days.
Triple span of 2 850 mm, total slab thickness of 140 mm with 65 mm of
During construction, the steel deck must support itself, the concrete and concrete cover on top of 76 mm deck profile.
a construction uniform load of 1 kPa or a transverse load of 2 kN/m as
specified by the Canadian Sheet Steel Building Institute. Once the concrete is cured, the composite slab will have to support these
loads:
The maximum unshored spans shown in the table are established for Dead load = 1.50 kPa
bending under the slab self-weight and the construction loads, for web Service live load = 4.80 kPa
crippling and for the deflection under wet concrete to be less than the
span over 180 (L/180). The web crippling resistance is calculated According to the table of maximum unshored span above, we need to use
assuming the end bearing length equal to 76 mm and the interior a deck with a nominal thickness of 0.91 mm for a triple span condition.
bearing length equal to 152 mm. Deck and concrete weight is 2.51 kPa (shown in the table).
If the bearing length is shorter, the design engineer must verify the Total factored load
web crippling factored resistance with the reaction produced by wet wf = 1.25 x (2.51 + 1.50) + 1.5 x 4.80 = 12.21 kPa
concrete and construction factored loads (refer to page 24 for web
Factored resistance
crippling tables and examples).
wr = 13.43 kPa for a span of 2 850 mm, with a 140 mm slab and a 0.91 mm
Contact Canam sales personnel when the total uniform load exceeds thick deck.
20 kPa, as this is an indication that significant concentrated loads will wr > wf OK
be used.The composite slab and its reinforcing should be verified for
the effect of concentrated loads (see notes on page 5). Service load w = 4.80 kPa
Composite moment of inertia is 15.410 x106 mm4 (from the table).
Shaded values indicate that the deck should be shored at mid-span
during the pour and the curing of concrete for those spans and 5 w L4 5 x 4.80 x 2 8504
concrete thickness conditions. Shaded values correspond to the Deflection = =
maximum unshored span values shown at the left of the table. 384 Es Icomp 384 x 203 000 x 15 410 000

The design engineer is responsible for specifying size and location 2 850
of the wire mesh in the concrete slab in order to respect current = 1.3 mm < = 7.9 mm OK
concrete practices. 360

19
P-2432 COMPOSITE
FACTORED RESISTANCE TABLE OF COMPOSITE SLAB (psf) IMPERIAL
Slab Deck Maximum Unshored Span Self Comp. Mom. SPAN (ft.-in.)
Thick. Thick. Single Double Triple Weight of Inertia
(in.) (in.) (ft.-in.) (ft.-in.) (ft.-in.) (psf) (in4) 7-0 7-6 8-0 8-6 9-0 9-6 10-0 10-6 11-0 11-6 12-0 12-6 13-0
5.00
0.030 7 - 11 7 -11 8 - 3 45.7 8.167 368 320 282 249 223 200 180 163 149 136 125 115 107
0.036 10 -10 10 -10 11 - 4 46.0 8.650 419 368 327 292 263 238 217 198 182 168 156 145 135
0.048 13 - 1 13 -11 14 - 4 46.7 9.578 420 420 420 410 374 344 317 294 274 256 240 226 213
5.50
0.030 7 - 3 7 - 3 7 - 7 51.9 10.699 420 366 322 285 254 228 206 187 170 156 143 132 122
0.036 10 - 0 10 - 0 10 - 5 52.3 11.316 420 420 373 333 300 272 247 226 208 192 178 165 154
0.048 12 - 7 13 - 4 13 - 9 52.9 12.497 420 420 420 420 420 393 362 336 313 292 274 258 243
6.00
0.030 6 - 8 6 - 8 7 - 0 58.2 13.713 420 411 362 320 286 256 231 210 191 175 161 148 137
0.036 9 - 3 9 - 3 9 - 8 58.5 14.488 420 420 419 375 337 305 278 254 234 216 200 186 173
0.048 12 - 1 12 -10 13 - 3 59.2 15.970 420 420 420 420 420 420 408 378 352 329 308 290 273
6.50
0.030 6 - 3 6 - 3 6 - 6 64.4 17.255 420 420 402 356 317 285 257 233 212 194 178 164 152
0.036 8 - 7 8 - 7 8 -11 64.8 18.212 420 420 420 416 375 339 309 283 260 240 222 206 192
0.048 11 - 9 12 - 4 12 - 9 65.4 20.044 420 420 420 420 420 420 420 420 391 365 342 322 304
7.50
0.030 5 - 6 5 - 6 5 - 8 76.9 26.107 420 420 420 420 380 341 308 280 255 233 214 197 182
0.036 7 - 6 7 - 6 7 -10 77.3 27.502 420 420 420 420 420 407 370 339 311 287 266 247 231
0.048 11 - 1 11 - 7 12 - 0 77.9 30.178 420 420 420 420 420 420 420 420 420 420 411 386 364
8.00
0.030 5 - 2 5 - 2 5 - 4 83.2 31.505 420 420 420 420 412 370 334 303 276 252 232 214 197
0.036 7 - 1 7 - 1 7 - 5 83.5 33.157 420 420 420 420 420 420 401 367 337 311 288 268 250
0.048 10 - 9 11 - 3 11 - 8 84.2 36.330 420 420 420 420 420 420 420 420 420 420 420 418 394

The table is based on concrete density of 150 lb/ft3 and minimum EXAMPLE
compressive resistance (fc ) equal to 3 000 psi at 28 days.
Triple span of 9-6, total slab thickness of 5 1/2 with 2 1/2 of concrete
During construction, the steel deck must support itself, the concrete and cover on top of 3 deck profile.
a construction uniform load of 21 psf or a transverse load of 137 plf as
specified by the Canadian Sheet Steel Building Institute. Once the concrete is cured, the composite slab will have to support these
loads:
The maximum unshored spans shown in the table are established for Dead load = 30 psf
bending under the slab self-weight and the construction loads, for web Service live load = 100 psf
crippling and for the deflection under wet concrete to be less than the
span over 180 (L/180). The web crippling resistance is calculated According to the table of maximum unshored span above, we need to use
assuming the end bearing length equal to 3 in. and the interior a deck with a nominal thickness of 0.036 for a triple span condition.
bearing length equal to 6 in. Deck and concrete weight is 52.3 psf (shown in the table).
If the bearing length is shorter, the design engineer must verify the Total factored load
web crippling factored resistance with the reaction produced by wet wf = 1.25 x (52.3 + 30) + 1.5 x 100 = 253 psf
concrete and construction factored loads (refer to page 24 for web
Factored resistance
crippling tables and examples).
wr = 272 psf for a span of 9-6, with a 5 1/2 slab and a 0.036 thick deck.
Contact Canam sales personnel when the total uniform load exceeds wr > wf OK
420 psf, as this is an indication that significant concentrated loads will
be used. The composite slab and its reinforcing should be verified for Service load w = 100 psf
the effect of concentrated loads (see notes on page 5). Composite moment of inertia is 11.316 in4 (from the table).
Shaded values indicate that the deck should be shored at mid-span 5 w L4 5 x 100 x 9.54 x 1 728
during the pour and the curing of concrete for those spans and Deflection = =
concrete thickness conditions. Shaded values correspond to the 384 Es Icomp 384 x 29 500 x 11.316 x 1 000
maximum unshored span values shown at the left of the table.
114
The design engineer is responsible for specifying size and location = 0.05 <
360
= 0.32 OK
of the wire mesh in the concrete slab in order to respect current
concrete practices.

20
P-2432 COMPOSITE
FACTORED RESISTANCE TABLE OF COMPOSITE SLAB (kPa) LIGHTWEIGHT CONCRETE - METRIC
Slab Deck Maximum Unshored Span Self Comp. Mom. SPAN (mm)
Thick. Thick. Single Double Triple Weight of Inertia
(mm) (mm) (mm) (mm) (mm) (kPa) (106 mm4) 2 100 2 250 2 400 2 550 2 700 2 850 3 000 3 150 3 300 3 450 3 600 3 750 3 900
125
0.76 2 865 2 865 2 980 1.66 8.555 17.78 15.48 13.61 12.06 10.75 9.65 8.71 7.90 7.20 6.59 6.05 5.57 5.15
0.91 3 755 3 810 3 940 1.68 9.131 20.00 17.76 15.75 14.07 12.66 11.46 10.43 9.55 8.77 8.09 7.49 6.96 6.49
1.21 4 385 4 615 4 770 1.71 10.229 20.00 20.00 20.00 19.68 17.97 16.50 15.22 14.11 13.13 12.27 11.50 10.81 10.20
140
0.76 2 615 2 615 2 725 1.93 11.751 20.00 18.14 15.94 14.12 12.60 11.31 10.20 9.25 8.43 7.72 7.09 6.53 6.04
0.91 3 555 3 595 3 745 1.95 12.518 20.00 20.00 18.45 16.49 14.83 13.43 12.23 11.18 10.28 9.48 8.78 8.16 7.61
1.21 4 175 4 410 4 560 1.98 13.972 20.00 20.00 20.00 20.00 20.00 19.33 17.84 16.54 15.39 14.38 13.48 12.67 11.95
150
0.76 2 470 2 470 2 575 2.11 14.281 20.00 19.91 17.50 15.50 13.83 12.41 11.20 10.16 9.26 8.47 7.78 7.17 6.63
0.91 3 400 3 400 3 540 2.13 15.198 20.00 20.00 20.00 18.10 16.28 14.74 13.42 12.28 11.28 10.41 9.64 8.96 8.35
1.21 4 055 4 290 4 435 2.16 16.937 20.00 20.00 20.00 20.00 20.00 20.00 19.58 18.15 16.90 15.79 14.80 13.91 13.12
165
0.76 2 285 2 285 2 380 2.38 18.729 20.00 20.00 19.83 17.57 15.67 14.06 12.69 11.51 10.49 9.60 8.81 8.12 7.51
0.91 3 145 3 145 3 275 2.40 19.910 20.00 20.00 20.00 20.00 18.46 16.71 15.21 13.91 12.79 11.80 10.92 10.15 9.46
1.21 3 900 4 130 4 265 2.43 22.145 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 19.16 17.90 16.77 15.77 14.87
190
0.76 2 030 2 030 2 115 2.83 28.069 20.00 20.00 20.00 20.00 18.74 16.82 15.18 13.77 12.55 11.48 10.54 9.72 8.98
0.91 2 795 2 795 2 910 2.85 29.787 20.00 20.00 20.00 20.00 20.00 19.99 18.19 16.64 15.29 14.11 13.07 12.14 11.32
1.21 3 685 3 895 4 025 2.88 33.047 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 18.87 17.79
200
0.76 1 940 1 940 2 025 3.01 32.542 20.00 20.00 20.00 20.00 19.97 17.92 16.18 14.67 13.37 12.23 11.23 10.35 9.57
0.91 2 675 2 675 2 785 3.03 34.511 20.00 20.00 20.00 20.00 20.00 20.00 19.39 17.74 16.30 15.04 13.92 12.94 12.06
1.21 3 610 3 810 3 940 3.06 38.251 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 20.00 18.96

The table is based on concrete density of 1 840 kg/m3 and minimum compressive resistance (fc) equal to 25 MPa at 28 days.
Refer to page 19 for other notes.
FACTORED RESISTANCE TABLE OF COMPOSITE SLAB (psf) LIGHTWEIGHT CONCRETE - IMPERIAL
Slab Deck Maximum Unshored Span Self Comp. Mom. SPAN (ft.-in.)
Thick. Thick. Single Double Triple Weight of Inertia
(in.) (in.) (ft.-in.) (ft.-in.) (ft.-in.) (psf) (in4) 7-0 7-6 8-0 8-6 9-0 9-6 10-0 10-6 11-0 11-6 12-0 12-6 13-0
5.00
0.030 9 - 3 9 - 3 9 - 7 35.5 6.704 368 320 282 249 223 200 180 163 149 136 125 115 107
0.036 12 - 2 12 - 5 12 -10 35.8 7.147 419 368 327 292 263 238 217 198 182 168 156 145 135
0.048 14 - 3 15 - 0 15 - 6 36.5 7.993 420 420 420 410 374 344 317 294 274 256 240 226 213
5.50
0.030 8 - 7 8 - 7 8 -11 40.3 8.760 420 366 322 285 254 228 206 187 170 156 143 132 122
0.036 11 - 8 11 - 9 12 - 3 40.6 9.324 420 420 373 333 300 272 247 226 208 192 178 165 154
0.048 13 - 8 14 - 5 14 -11 41.3 10.397 420 420 420 420 420 393 362 336 313 292 274 258 243
6.00
0.030 8 - 0 8 - 0 8 - 4 45.1 11.206 420 411 362 320 286 256 231 210 191 175 161 148 137
0.036 11 - 0 11 - 0 11 - 5 45.4 11.914 420 420 419 375 337 305 278 254 234 216 200 186 173
0.048 13 - 2 13 -11 14 - 5 46.1 13.258 420 420 420 420 420 420 408 378 352 329 308 290 273
6.50
0.030 7 - 5 7 - 5 7 - 9 49.9 14.076 420 420 402 356 317 285 257 233 212 194 178 164 152
0.036 10 - 3 10 - 3 10 - 8 50.2 14.952 420 420 420 416 375 339 309 283 260 240 222 206 192
0.048 12 - 9 13 - 6 14 - 0 50.8 16.613 420 420 420 420 420 420 420 420 391 365 342 322 304
7.50
0.030 6 - 7 6 - 7 6 -11 59.4 21.227 420 420 420 420 380 341 308 280 255 233 214 197 182
0.036 9 - 1 9 - 1 9 - 6 59.8 22.509 420 420 420 420 420 407 370 339 311 287 266 247 231
0.048 12 -0 12 - 9 13 - 2 60.4 24.943 420 420 420 420 420 420 420 420 420 420 411 386 364
8.00
0.030 6 - 3 6 - 3 6 - 6 64.2 25.575 420 420 420 420 412 370 334 303 276 252 232 214 197
0.036 8 - 7 8 - 7 9 - 0 64.6 27.095 420 420 420 420 420 420 401 367 337 311 288 268 250
0.048 11 - 9 12 - 5 12 -10 65.2 29.988 420 420 420 420 420 420 420 420 420 420 420 418 394

The table is based on concrete density of 115 lb/ft3 and minimum compressive resistance (fc) equal to 4 000 psi at 28 days.
Refer to page 20 for other notes.

21
P-3012 FORM DECK
Canams P-3012 is a steel deck roll formed to cover 762 mm (30 in.).
The deck is available with a galvanized coating according to the standard
ASTM A 653M with zinc thickness corresponding to Z275 (G90) or with
uncoated steel. Contact our sales department for more information.
Standard thicknesses are 0.38 mm (0.015 in.),
0.46 mm (0.018 in.) and 0.61 mm
(0.024 in.). The flutes are
14 mm (9/16 in.) deep
and are spaced
at 64 mm (2.5 in.)
center to center. The
deck can be rolled to lengths as
per your request or stocked in 6 200 mm
(20 ft. 4 in.) length to cover multiple spans.
Steel grade conforms to ASTM A 653M with a
minimum yield strength of 410 MPa (60 ksi).

DIMENSIONS

PHYSICAL PROPERTIES
Nominal Design Overall Section Moment
Type Weight
Thickness Thickness Depth Modulus of Inertia
mm mm mm kg/m2 mm3 mm4
(in.) (in.) (in.) (lb/ft2) (in3) (in4)
0.38 0.378 14.2 4.37 1 834 15 270
28
(0.015) (0.0149) (0.56) (0.90) (0.0341) (0.0112)
0.46 0.455 14.3 5.15 2 386 19 318
26
(0.018) (0.0179) (0.56) (1.06) (0.0444) (0.0141)
0.61 0.607 14.4 6.71 3 566 27 483
24
(0.024) (0.0239) (0.57) (1.37) (0.0663) (0.0201)

Effective properties are based on a unit width of 1 000 mm (S.I. units) or 12 in. (imperial units).
Material according to ASTM A 653M, minimum yield strength of 410 MPa (60 ksi).
Tables are calculated according to CAN/CSA-S136-01 standard.

22
P-3012 FORM DECK
MAXIMUM CONCRETE SLAB THICKNESS TABLE (mm) METRIC
Nominal SPAN (mm)
Type
Thickness (mm) 700 750 800 850 900 950 1 000
28 0.38 100 100 100 80 60 --- ---
26 0.45 100 100 100 100 100 85 75
24 0.61 100 100 100 100 100 100 100

FACTORED RESISTANCE TABLE OF CONCRETE SLAB WITH WIRE MESH (kPa) METRIC
Slab Thick. Self Weight Welded Wire Fabric Wire Diam. Wire Area SPAN (mm)
(mm) (kPa) Designation (mm) (mm2/m) 700 750 800 850 900 950 1 000
152 x 152 MW 13.3 x MW 13.3 4.10 88.7* 11.85 10.32 9.07 8.03 7.17 6.49 5.80
65 1.47 152 x 152 MW 18.7 x MW 18.7 4.88 124.5 20.00 18.61 16.36 14.49 12.93 11.60 10.47
152 x 152 MW 25.8 x MW 25.8 5.74 171.5 20.00 18.75 17.58 16.55 15.63 14.81 13.71
152 x 152 MW 13.3 x MW 13.3 4.10 88.7* 14.22 12.38 10.88 9.64 8.60 7.72 6.97
75 1.71 152 x 152 MW 18.7 x MW 18.7 4.88 124.5* 19.35 16.86 14.82 13.13 11.71 10.51 9.48
152 x 152 MW 25.8 x MW 25.8 5.74 171.5 20.00 20.00 20.00 19.09 18.03 17.08 16.23
152 x 152 MW 18.7 x MW 18.7 4.88 124.5* 20.00 20.00 18.64 16.51 14.73 13.22 11.93
90 2.06 152 x 152 MW 25.8 x MW 25.8 5.74 171.5 20.00 20.00 20.00 20.00 20.00 20.00 19.48
152 x 152 MW 18.7 x MW 18.7 4.88 124.5* 20.00 20.00 20.00 18.77 16.74 15.02 13.56
100 2.30
152 x 152 MW 25.8 x MW 25.8 5.74 171.5* 20.00 20.00 20.00 20.00 20.00 20.00 18.14

MAXIMUM CONCRETE SLAB THICKNESS TABLE (in.) IMPERIAL


Nominal SPAN (ft.-in.)
Type
Thickness (mm) 2-0 2-3 2-6 2-9 3-0 3-3 3-6
28 0.015 4.00 4.00 4.00 3.50 --- --- ---
26 0.018 4.00 4.00 4.00 4.00 3.75 3.00 2.50
24 0.024 4.00 4.00 4.00 4.00 4.00 4.00 3.50

FACTORED RESISTANCE TABLE OF CONCRETE SLAB WITH WIRE MESH (psf) IMPERIAL
Slab Thick. Self Weight Welded Wire Fabric Wire Diam. Wire Area SPAN (ft.-in.)
(in.) (psf) Designation (in.) (in2/ft.) 2-0 2-3 2-6 2-9 3-0 3-3 3-6
6 x 6 W2.1 x W2.1 0.162 0.042* 316 250 202 167 141 120 103
2.50 30 6 x 6 W2.9 x W2.9 0.192 0.059 420 420 365 302 254 216 186
6 x 6 W4.0 x W4.0 0.226 0.081 420 420 383 348 319 283 244
6 x 6 W2.1 x W2.1 0.162 0.042* 399 315 255 211 177 151 130
3.00 36 6 x 6 W2.9 x W2.9 0.192 0.059* 420 420 348 288 242 206 178
6 x 6 W4.0 x W4.0 0.226 0.081 420 420 420 418 383 354 314
6 x 6 W2.9 x W2.9 0.192 0.059* 420 420 420 349 293 250 215
3.50 42 6 x 6 W4.0 x W4.0 0.226 0.081 420 420 420 420 420 412 383
6 x 6 W2.9 x W2.9 0.192 0.059* 420 420 420 410 345 294 253
4.00 49 6 x 6 W4.0 x W4.0 0.226 0.081* 420 420 420 420 420 394 340

Wire fabric steel: Fy = 450 MPa (65 ksi). Welded wire mesh area marked with an asterisk (*) means it does
not satisfy the clause 7.8.1 of the CAN/CSA-A23.3-94 standard
The tables are based on concrete density of 2 400 kg/m3 (150 lb/ft3) and regarding minimum reinforcement.
minimum compressive resistance fc = 20 MPa (3.00 ksi) at 28 days.
Maximum spans of P-3012 form deck are calculated for different slab A total uniform load that exceeds 20 kPa (420 psf) is an indication that
significant concentrated loads will be applied on that floor. In that
thicknesses taking into account: case, the composite slab and its reinforcing should be verified for the
- The weight of wet concrete; effect of concentrated loads (see notes on page 5).
- A construction load of 1 kPa (21 psf) uniformly distributed or
a transverse load of 2 kN/m (137 plf) as specified by the EXAMPLE METRIC
Canadian Sheet Steel Building Institute; Slab thickness = 65 mm
- A triple span condition;
Dead load = 1.50 kPa
- A maximum deflection of the span over 240 (L/240) under the
Service live load = 2.40 kPa
wet concrete;
- The height of the steel form deck included in the slab thickness. Deck and concrete weight is 1.47 kPa (from the table).
The resistance of the slab is computed considering that welded wire Total factored load = 1.25 x (1.47 + 1.50) + 1.5 x 2.40 = 7.31 kPa
mesh is held at mid-height of the concrete thickness above the deck.
We can select a P-3012 form deck 0.38 mm thick with multiple spans
The reinforced slab must resist to a negative moment computed
of 850 mm on center for 65 mm slab with a welded wire fabric 152 x 152 x
as 0.116 wf L2 over the support and to a positive moment computed
as 0.100 wf L2 at mid-span. Maximum shear is computed as 0.620 wf L. MW13.3 x MW13.3 maintained at mid-depth of the concrete thickness above
the deck. Once cured, the concrete slab can safely support 8.03 kPa which is
Steel form deck does not supply resistance under service load. greater than the total factored load.

23
DESIGN AIDS - WEB CRIPPLING*
WEB CRIPPLING FACTORED RESISTANCE TABLE (kN/m of width) METRIC
Nominal BEARING LENGTH (mm)
Reaction
Profile Type Thickness
(mm) Type 40 50 65 75 90 100 115 125
End 11.00 11.84 12.95 13.62 14.54 15.12 15.93 16.44
22 0.76
Interior 14.36 15.29 16.53 17.28 18.32 18.96 19.87 20.44
End 15.23 16.35 17.83 18.73 19.97 20.74 21.83 22.52
20 0.91
P-3615 Interior 20.37 21.65 23.34 24.36 25.77 26.65 27.88 28.66
P-3606 End 25.97 27.77 30.17 31.61 33.61 34.85 36.60 37.71
18 1.21
Interior 36.01 38.10 40.89 42.57 44.89 46.34 48.37 49.65
End 38.62 41.18 44.59 46.64 49.48 51.24 53.73 55.30
16 1.52
Interior 54.82 57.84 61.85 64.27 67.61 69.68 72.61 74.46
End 10.65 11.46 12.53 13.18 14.08 14.63 15.42 15.91
22 0.76
Interior 16.83 17.92 19.38 20.26 21.47 22.22 23.29 23.96
End 14.85 15.94 17.39 18.27 19.48 20.23 21.29 21.96
20 0.91
P-2436 Interior 23.54 25.01 26.96 28.14 29.77 30.78 32.21 33.11
P-2404 End 25.59 27.37 29.73 31.15 33.12 34.35 36.07 37.16
18 1.21
Interior 40.80 43.18 46.34 48.24 50.87 52.51 54.81 56.27
End 38.30 40.85 44.22 46.26 49.08 50.82 53.29 54.85
16 1.52
Interior 61.41 64.79 69.28 71.99 75.73 78.05 81.33 83.40
End 5.48 5.90 6.45 6.79 7.25 7.53 7.94 8.19
22 0.76
Interior 7.99 8.51 9.20 9.62 10.20 10.56 11.06 11.38
End 7.60 8.16 8.91 9.35 9.97 10.36 10.90 11.24
20 0.91
Interior 11.22 11.92 12.85 13.41 14.19 14.67 15.35 15.78
P-3623
End 13.00 13.91 15.11 15.83 16.83 17.46 18.33 18.89
18 1.21
Interior 19.54 20.68 22.19 23.10 24.37 25.15 26.25 26.95
End 19.38 20.66 22.37 23.40 24.83 25.71 26.96 27.75
16 1.52
Interior 29.49 31.12 33.28 34.58 36.37 37.49 39.07 40.06
End 5.31 5.71 6.25 6.57 7.02 7.30 7.69 7.93
22 0.76
Interior 8.31 8.86 9.57 10.01 10.61 10.98 11.51 11.84
End 7.40 7.95 8.67 9.11 9.71 10.09 10.62 10.95
20 0.91
Interior 11.64 12.37 13.34 13.92 14.73 15.23 15.93 16.38
P-2432
End 12.77 13.65 14.83 15.54 16.53 17.14 18.00 18.54
18 1.21
Interior 20.22 21.40 22.96 23.91 25.21 26.02 27.16 27.88
End 19.11 20.38 22.07 23.08 24.49 25.36 26.59 27.37
16 1.52
Interior 30.46 32.14 34.37 35.71 37.57 38.72 40.35 41.38

WEB CRIPPLING FACTORED RESISTANCE TABLE (kip/ft. of width) IMPERIAL


Nominal BEARING LENGTH (in.)
Reaction
Profile Type Thickness
(in.) Type 1 1/2 2 2 1/2 3 3 1/2 4 4 1/2 5
End 0.74 0.82 0.88 0.94 0.99 1.04 1.09 1.13
22 0.030
Interior 0.97 1.05 1.12 1.19 1.25 1.31 1.36 1.41
End 1.03 1.13 1.21 1.29 1.36 1.43 1.49 1.55
20 0.036
P-3615 Interior 1.38 1.49 1.59 1.68 1.76 1.84 1.91 1.97
P-3606 End 1.75 1.91 2.05 2.18 2.29 2.40 2.50 2.60
18 0.048
Interior 2.44 2.62 2.78 2.93 3.06 3.19 3.31 3.42
End 2.61 2.84 3.03 3.21 3.38 3.53 3.67 3.81
16 0.060
Interior 3.71 3.98 4.21 4.42 4.62 4.80 4.97 5.13
End 0.72 0.79 0.85 0.91 0.96 1.01 1.05 1.10
22 0.030
Interior 1.14 1.23 1.32 1.40 1.47 1.53 1.59 1.65
End 1.00 1.10 1.18 1.26 1.33 1.39 1.46 1.51
20 0.036
P-2436 Interior 1.59 1.72 1.83 1.94 2.03 2.12 2.20 2.28
P-2404 End 1.73 1.88 2.02 2.15 2.26 2.37 2.47 2.56
18 0.048
Interior 2.76 2.97 3.15 3.32 3.47 3.62 3.75 3.87
End 2.59 2.81 3.01 3.19 3.35 3.50 3.64 3.78
16 0.060
Interior 4.16 4.46 4.72 4.95 5.17 5.37 5.56 5.74
End 0.37 0.41 0.44 0.47 0.49 0.52 0.54 0.56
22 0.030
Interior 0.54 0.59 0.63 0.66 0.70 0.73 0.76 0.78
End 0.51 0.56 0.61 0.64 0.68 0.71 0.75 0.78
20 0.036
Interior 0.76 0.82 0.87 0.92 0.97 1.01 1.05 1.09
P-3623
End 0.88 0.96 1.03 1.09 1.15 1.20 1.25 1.30
18 0.048
Interior 1.32 1.42 1.51 1.59 1.66 1.73 1.80 1.86
End 1.31 1.42 1.52 1.61 1.69 1.77 1.84 1.91
16 0.060
Interior 2.00 2.14 2.27 2.38 2.48 2.58 2.67 2.76
End 0.36 0.39 0.42 0.45 0.48 0.50 0.53 0.55
22 0.030
Interior 0.56 0.61 0.65 0.69 0.72 0.76 0.79 0.82
End 0.50 0.55 0.59 0.63 0.66 0.70 0.73 0.75
20 0.036
Interior 0.79 0.85 0.91 0.96 1.01 1.05 1.09 1.13
P-2432
End 0.86 0.94 1.01 1.07 1.13 1.18 1.23 1.28
18 0.048
Interior 1.37 1.47 1.56 1.65 1.72 1.79 1.86 1.92
End 1.29 1.40 1.50 1.59 1.67 1.75 1.82 1.89
16 0.060
Interior 2.06 2.21 2.34 2.46 2.57 2.67 2.76 2.85
* Web crippling is the failure of the vertical element of the deck flute due to high point load or excessive reaction.

24
DESIGN AIDS - WEB CRIPPLING

TYPICAL MOMENTS AND REACTIONS FOR ROOF


SINGLE SPAN

w : Uniformly distributed
M+ = 0.125 wL2 load on one span
Rend = 0.500 wL Rend = 0.500 wL L : Length of one span

Note: Unbalanced concrete loads


DOUBLE SPAN have to be considered for floor.
M- = 0.125 wL2 Refer to the Standard for
Composite Steel Deck from
the CSSBI for more details.
M+ = 0.070 wL2 M+ = 0.070 wL2
Rend = 0.375 wL Rint = 1.250 wL Rend = 0.375 wL

TRIPLE SPAN
M- = 0.100 wL2 M- = 0.100 wL2

M+ = 0.080 wL2 M+ = 0.025 wL2 M+ = 0.080 wL2


Rend = 0.400 wL Rint = 1.100 wL Rint = 1.100 wL Rend = 0.400 wL

ROOF EXAMPLE METRIC ROOF EXAMPLE IMPERIAL


Roof deck P-3615, 0.76 mm thick, span 1 650 mm. Dead load of 1.5 kPa and Roof deck P-3615, 0.030 thick, span 5-6. Dead load of 30 psf and
service load of 2.4 kPa. Exterior bearing width of 50 mm and interior service load of 50 psf. Exterior bearing width of 2 and interior bearing
bearing width of 100 mm. width of 4.
Total factored load = 1.25 x 1.5 + 1.5 x 2.4 = 5.48 kPa Total factored load = 1.25 x 30 + 1.5 x 50 = 112.5 psf
Single span Single span
End reaction = 0.5 x 5.48 x 1 650 / 1 000 End reaction = 0.5 x 112.5 x 5.5 / 1 000
= 4.52 kN/m < 11.84 kN/m OK (from the table) = 0.309 kip/ft. < 0.82 kip/ft. OK (from the table)
Double span Double span
End reaction = 0.375 x 5.48 x 1 650 / 1 000 End reaction = 0.375 x 112.5 x 5.5 / 1 000
= 3.39 kN/m < 11.84 kN/m OK (from the table) = 0.232 kip/ft. < 0.82 kip/ft. OK (from the table)
Interior reaction = 1.25 x 5.48 x 1 650 / 1 000 Interior reaction = 1.25 x 112.5 x 5.5 / 1 000
= 11.29 kN/m < 18.96 kN/m OK (from the table) = 0.773 kip/ft. < 1.31 kip/ft. OK (from the table)
Triple span Triple span
End reaction = 0.4 x 5.48 x 1 650 / 1 000 End reaction = 0.4 x 112.5 x 5.5 / 1 000
= 3.61 kN/m < 11.84 kN/m OK (from the table) = 0.248 kip/ft. < 0.82 kip/ft. OK (from the table)
Interior reaction = 1.1 x 5.48 x 1 650 / 1 000 Interior reaction = 1.1 x 112.5 x 5.5 / 1 000
= 9.94 kN/m < 18.96 kN/m OK (from the table) = 0.681 kip/ft. < 1.31 kip/ft. OK (from the table)

FLOOR EXAMPLE METRIC FLOOR EXAMPLE IMPERIAL


Composite deck P-3623, 0.91 mm thick, triple span of 2 250 mm. Slab Composite deck P-3623, 0.036 thick, triple span of 7-6. Slab thickness
thickness of 125 mm, 75 mm of concrete over 50 mm deck profile. Exterior of 5, 3 of concrete over 2 deck profile. Exterior bearing width of 2 and
bearing width of 50 mm and interior bearing width of 100 mm. During the interior bearing width of 4. During the construction, the steel deck must
construction, the steel deck must support itself, the concrete and a construc- support itself, the concrete and a construction uniform load of 21 psf
tion uniform load of 1 kPa or a transverse load of 2 kN/m specified by the or a transverse load of 137 plf specified by the Canadian Sheet Steel Building
Canadian Sheet Steel Building Institute. Institute.
Deck and concrete weight = 2.44 kPa (from page 15) Deck and concrete weight = 52.0 psf (from page 16)
Factored interior reaction: Factored interior reaction:
Pf = maximum of (1.25 x 2.44 + 1.5 x 1) x 1.2 x 2.25 = 12.29 kN/m Pf = maximum of (1.25 x 52.0 + 1.5 x 21) x 1.2 x 7.5 = 0.869 kip/ft.
or 1.25 x 2.44 x 1.2 x 2.25 + 1.5 x 2 x 0.575 = 9.96 kN/m or 1.25 x 52.0 x 1.2 x 7.5 + 1.5 x 137 x 0.575 = 0.703 kip/ft.
= 12.29 kN/m < 14.67 kN/m OK (from the table) = 0.869 kip/ft. < 1.01 kip/ft. OK (from the table)
Factored end reaction: Factored end reaction:
Pf = maximum of (1.25 x 2.44 + 1.5 x 1) x 0.450 x 2.25 = 4.61 kN/m Pf = maximum of (1.25 x 52.0 + 1.5 x 21) x 0.450 x 7.5 = 0.326 kip/ft.
or 1.25 x 2.44 x 0.450 x 2.25 + 1.5 x 2 x 0.400 = 4.29 kN/m or 1.25 x 52.0 x 0.450 x 7.5 + 1.5 x 137 x 0.400 = 0.302 kip/ft.
= 4.61 kN/m < 8.16 kN/m OK (from the table) = 0.326 kip/ft. < 0.56 kip/ft. OK (from the table)

25
DESIGN AIDS - ROOF CANTILEVER
MAXIMUM ROOF CANTILEVER TABLE (mm) METRIC
FACTORED LOAD (kPa)
Nominal Bearing
SERVICE LOAD (kPa)
Profile Type Thickness Width
3.00 3.60 4.20 4.80 5.40 6.00 6.60 7.20
(mm) (mm)
2.00 2.40 2.80 3.20 3.60 4.00 4.40 4.80
22 0.76 650 650 650 650 625 595 565 540
P-3615 20 0.91 825 825 800 750 705 670 635 610
100
P-3606 18 1.21 955 910 870 840 815 775 735 705
16 1.52 1 015 965 925 895 865 840 820 785
22 0.76 1 395 1 270 1 175 1 075 955 860 780 715
P-2436 20 0.91 1 540 1 405 1 300 1 215 1 145 1 085 1 035 985
150
P-2404 18 1.21 1 680 1 600 1 505 1 405 1 325 1 255 1 200 1 145
16 1.52 1 785 1 700 1 630 1 570 1 480 1 400 1 335 1 280

MAXIMUM ROOF CANTILEVER TABLE (ft.-in.) IMPERIAL


FACTORED LOAD (psf)
Nominal Bearing
SERVICE LOAD (psf)
Profile Type Thickness Width
45 60 75 90 105 120 135 150
(in.) (in.)
30 40 50 60 70 80 90 100
22 0.76 2 - 1 2 - 1 2 - 1 2 - 1 2 - 1 2 - 0 1 -10 1 - 9
P-3615 20 0.91 2 - 7 2 - 7 2 - 7 2 - 6 2 - 4 2 - 2 2 - 0 1 - 11
4
P-3606 18 1.21 3 - 5 3 - 2 2 - 11 2 - 10 2 - 8 2 - 7 2 - 5 2 - 3
16 1.52 3 - 7 3 - 4 3 - 2 3 - 0 2 - 10 2 - 9 2 - 8 2 - 7
22 0.76 5 - 2 4 - 6 4 - 0 3 - 8 3 - 4 2 -11 2 - 7 2 - 4
P-2436 20 0.91 5 - 7 5 - 0 4 - 5 4 - 1 3 - 9 3 - 6 3 - 4 3 - 1
6
P-2404 18 1.21 6 - 0 5 - 7 5 - 3 4 - 9 4 - 5 4 - 2 3 - 11 3 - 8
16 1.52 6 - 4 5 - 11 5 - 7 5 - 3 5 - 0 4 - 8 4 - 5 4 - 2

The maximum roof cantilevers shown in the tables are checked for Uniform Factored Load
bending under the factored uniform load, for web crippling with the
specified bearing length, and for the deflection to be less than
the span over 120 (L/120) or 19 mm (3/ 4 in.).

Also, the maximum roof cantilevers are verified to support a transverse


load of 2 kN/m (137 plf).

The sidelaps must be attached at the end of the cantilever and at a


maximum of 300 mm (12 in.) on center from the end.

The deck must be completely attached to the supports and at the


sidelaps before any load is applied to the cantilever. Bearing
Width
A structural1 engineer must be consulted if the cantilever span exceeds
one third ( / 3) of the adjacent span.
Adjacent Cantilever
Span Span

26
DESIGN AIDS - FLOOR CANTILEVER
MAXIMUM CANTILEVER SPAN FOR CONCRETE POUR TABLE (mm) METRIC
Nominal SLAB THICKNESS (mm) Bearing
Profile Type Thickness Width
(mm) 100 115 125 140 150 165 190 200 (mm)
22 0.76 570 555 545 530 525 510 495 490
P-3615
20 0.91 610 590 580 560 550 540 520 510 100
P-3606
18 1.21 650 630 615 600 590 575 555 550
22 0.76 720 710 705 695 690 685 600 565
P-3623 20 0.91 740 715 700 680 675 670 660 655 125
18 1.21 795 765 750 730 715 700 675 665
22 0.76 N/A N/A 1 030 1 015 1 005 940 780 730
P-2432 20 0.91 N/A N/A 1 010 1 000 990 980 965 955 150
18 1.21 N/A N/A 1 080 1 045 1 025 1 000 960 945

MAXIMUM CANTILEVER SPAN FOR CONCRETE POUR TABLE (ft.-in.) IMPERIAL


Nominal SLAB THICKNESS (in.) Bearing
Profile Type Thickness Width
(in.) 4 4 1/2 5 5 1/2 6 6 1/2 7 1/2 8 (in.)
22 0.76 1 -10 1 - 9 1 - 9 1 - 9 1 - 8 1 - 8 1 - 7 1 - 7
P-3615
20 0.91 2 - 0 1 - 11 1 - 10 1 - 10 1 - 9 1 - 9 1 - 8 1 - 8 4
P-3606
18 1.21 2 - 1 2 - 0 2 - 0 1 - 11 1 - 11 1 -10 1 - 9 1 - 9
22 0.76 2 - 4 2 - 3 2 - 3 2 - 3 2 - 3 2 - 2 1 - 11 1 - 10
P-3623 20 0.91 2 - 5 2 - 4 2 - 3 2 - 2 2 - 2 2 - 2 2 - 1 2 - 1 5
18 1.21 2 - 7 2 - 6 2 - 5 2 - 4 2 - 4 2 - 3 2 - 2 2 - 2
22 0.76 N/A N/A 3 - 4 3 - 3 3 - 3 3 - 1 2 - 6 2 - 4
P-2432 20 0.91 N/A N/A 3 - 3 3 - 3 3 - 2 3 - 2 3 - 1 3 - 1 6
18 1.21 N/A N/A 3 - 6 3 - 5 3 - 4 3 - 3 3 - 1 3 - 1
N/A Not applicable

The tables are based on a concrete weight of 2 400 kg/m3 (150 lb/ft3).

Thickness
Steel reinforcing (by others) required for

Slab
The maximum floor cantilevers shown in the table are checked negative bending under service loads
for bending under the self weight and the construction loads, for web
crippling with the specified bearing length, and for the deflection
under wet concrete to be less than the span over 120 (L/120) or
19 mm (3/ 4).

During the construction, the steel deck must support itself, the wet
Height
concrete and a construction uniform load of 1 kPa (21 psf) or a
Deck
transverse load of 2 kN/m (137 plf) as specified by the Canadian
Sheet Steel Building Institute.

The sidelaps must be attached at the end of the cantilever and at


a maximum of 300 mm (12 in.) on center from the end.
Bearing
The deck must be completely attached to the supports and at the Width
sidelaps before any load is applied to the cantilever.

A structural1 engineer must be consulted if the cantilever span exceeds Adjacent Cantilever
one third ( / 3) of the adjacent span. Span Span
The designer is responsible to add steel reinforcement for negative
bending under service loads in order to respect the standard
CAN/CSA A23.3-94.

27
DESIGN AIDS - POUR STOP
POUR STOP SELECTION TABLE METRIC
Slab Depth OVERHANG (mm)
(mm) 0 25 50 75 100 125 150 175 200 225 250 275 300
100 20 20 20 20 18 16 14 14 12 12 12 10 10
110 20 20 20 18 18 16 14 12 12 12 10 10 10
120 20 20 20 18 16 16 14 12 12 12 10 10 10
130 20 20 18 18 16 14 14 12 12 12 10 10
140 20 20 18 18 16 14 12 12 12 10 10 10
150 18 18 18 16 16 14 12 12 12 10 10
160 18 18 18 16 14 14 12 12 12 10 10
170 18 18 16 16 14 12 12 12 10 10 10
180 16 16 16 14 14 12 12 12 10 10
190 16 16 16 14 14 12 12 12 10 10
200 16 16 14 14 12 12 12 10 10 10
210 14 14 14 14 12 12 12 10 10
220 14 14 14 12 12 12 10 10 10
230 14 14 14 12 12 12 10 10 10 DESIGN THICKNESS
240 14 12 12 12 12 12 10 10 TYPES
(mm) (in.)
250 12 12 12 12 12 10 10 10
260 12 12 12 12 12 10 10 10 20 0.91 0.0358
18 1.20 0.0474
270 12 12 12 12 10 10 10 16 1.52 0.0598
280 12 12 12 12 10 10 10 14 1.90 0.0747
290 12 12 12 10 10 10 12 2.66 0.1046
300 12 12 10 10 10 10 10 3.42 0.1345

POUR STOP SELECTION TABLE IMPERIAL


Slab Depth OVERHANG (in.)
(in.) 0 1 2 3 4 5 6 7 8 9 10 11 12
4 20 20 20 18 18 16 14 14 12 12 10 10 10
4 1/2 20 20 20 18 16 16 14 12 12 12 10 10 10
5 20 20 18 18 16 14 14 12 12 12 10 10
5 1/2 20 20 18 18 16 14 12 12 12 10 10 10
6 18 18 18 16 14 14 12 12 12 10 10
6 1/2 18 18 16 16 14 14 12 12 10 10 10
7 18 16 16 14 14 12 12 12 10 10
7 1/2 16 16 16 14 14 12 12 10 10 10
8 16 16 14 14 12 12 12 10 10
8 1/2 14 14 14 12 12 12 12 10 10
9 14 14 14 12 12 12 10 10 10
9 1/2 14 12 12 12 12 12 10 10
10 12 12 12 12 12 10 10 10
10 1/2 12 12 12 12 10 10 10
11 12 12 12 12 10 10 10
11 1/2 12 12 12 10 10 10
12 10 10 10 10 10 10

The tables are based on a concrete weight of 2 400 kg/m3 (150 lb/ft3). 25 mm (1 in.) Fillet Welds
The concrete dead load is temporarily increased by one-third for the @ 305 mm (12 in.) o.c. Slab
construction load. Depth
The pour stop is calculated to support the concrete weight and the
construction load assumed as a uniform load of 1 kPa (21 psf) or a
transverse load of 2 kN/m (137 plf).
Horizontal and vertical deflections are limited to 6.3 mm (0.25 in.). Overhang
The pour stop selection table does not consider the effect of the 51 mm (2 in.) min.
performance, deflection, or rotation of the pour stop support, which
m .
may include both the supporting composite deck and/or the frame. m min
3
1 in.)
Vertical leg return lip is recommended for all types. (1 /
2

The designer is responsible to add steel reinforcement for slab under


service loads in order to respect the standard CAN/CSA-A23.3-94.
These selection tables are not meant to replace the judgment of experi-
enced structural engineers and should be considered as a reference only.

28
DESIGN AIDS - CLOSURE STRIP
CLOSURE STRIP SELECTION TABLE METRIC
Slab Depth SPAN (mm)
(mm) 100 125 150 175 200 225
100 20 18 18 16 16 14
110 20 18 18 16 16 14
120 20 18 18 16 14 14
130 20 18 18 16 14 14
140 20 18 18 16 14 14
150 20 18 16 16 14 14

CLOSURE STRIP SELECTION TABLE IMPERIAL


Slab Depth SPAN (in.)
(in.) 4 5 6 7 8 9
4 20 18 18 16 16 14
4 1/2 20 18 18 16 14 14
5 20 18 18 16 14 14
5 1/2 20 18 16 16 14 14
6 20 18 16 16 14 14

The tables are based on a concrete density of 2 400 kg/m3 (150 lb/ft3). TYPES
DESIGN THICKNESS
(mm) (in.)
The closure strip is calculated to support the concrete weight and 20 0.91 0.0358
the construction load assumed as a uniform load of 1 kPa (21 psf) or
18 1.20 0.0474
a transverse load of 2 kN/m (137 plf).
16 1.52 0.0598
The deflection is limited to 6.3 mm (0.25 in.). 14 1.90 0.0747
12 2.66 0.1046
The closure strip selection table does not consider the effect of the 10 3.42 0.1345
performance, deflection, or rotation of the closure strip supports,
which may include both the steel deck and the frame.
Tack Weld @
These selection tables are not meant to replace the judgment of
610 mm (24 in.) o.c. maximum
experienced structural engineers and shall be considered as a
reference only.

Span
25 mm
(1 in.)

29
ACCESSORIES

C EDGE STRIP Z EDGE STRIP

240 mm
(9 1/2) 38 mm
(1 1/2)
200 mm
38 mm (8)
(1 1/2) 190 mm
38 mm 230 mm (7 1/2)
(1 1/2) (9)
25 mm 76 mm
(1) (3) 76 mm
(3)

25 mm
(1) 38 mm
(1 1/2)
Note: Pieces are 3 048 mm (10 feet) long.

POUR STOP CELL CLOSURE

Pour stop can be selected using


the table on page 28 and obtained
by contacting our sales office. Note: Pieces are 3 048 mm (10 feet) long.

SUMP PAN COVER PLATE


838 mm
(33)
76 mm
(3)
737 mm
(29)

200 mm
(8)

Note: Thickness of 1.90 mm (0.075 in.). Note: Pieces are 3 048 mm (10 feet) long.

30
ACCESSORIES

NEOPRENE AND METAL CLOSURES

METAL CLOSURES NEOPRENE CLOSURES


Nominal thickness: Thickness:
0.76 mm (0.030 in.) 25 mm (1 in.)

Large cell closure

AVAILABILITY Small cell closure


Neoprene Metal
Deck Profile
Small Large Small Large
P-3615 & P-3606 Yes Yes Yes Yes
P-2436 & P-2404 Yes Yes Yes Yes
P-3623 Yes Yes Note: Please specify whether you need
P-2432 Yes Yes metal closures or L-shaped cell closures.
P-3012 No No

Z CLOSURE CLOSURE STRIP

Closure strip can be selected using


the table on page 29 and obtained
by contacting our sales office.

Note: Pieces are 3 048 mm (10 feet) long.

31
DECK FEATURES

VENTED DECK

When cementitious insulation fills are used, the deck sheet


shall have an appropriate galvanized finish and
the deck profile must be adequately vented.
On request, Canam can
produce vent slits like the
one shown below.
The small slits are
made upwards in each
bottom flute at a frequency that gives
openings equal to 0.5% of the deck
covered surface.
The vents allow the water contained
in the cementitious insulation fills to
evaporate even after the top of the
insulation fill is sealed by
a roof membrane.

Note: Available only with


P-3623 and P-2432.

INTEGRAL HANGER TAB

32
DECK FEATURES

ACOUSTICAL DECK
Acoustic roof deck provides a ceiling that can difference in noise from one side of a partition to
reduce noise reverberation while maintaining an the other. The STC value of Canams acoustical deck
adequate vertical and horizontal load resistance. assemblies has not been measured.
The perforations of Canams acoustical roof An experienced acoustical consultant can use the
deck profiles are limited in quantity and size and are NRC acoustic properties of Canams steel deck profiles
located only in the web elements in order to maintain to evaluate the effect of the acoustical deck surface for
vertical load resistance equal to 95% of the standard noise reduction and speech audition in a building.
deck resistance.
Tests were made in the laboratories of The National
The reduction in reverberation is mainly achieved Research Council of Canada in Ottawa, in accordance
when the sound passes through the staggered with the requirements of ASTM C423, in order to
perforations made in the web elements of the deck and determine the sound absorption coefficients of our
dampens by losing energy through the small holes standard acoustical deck profiles. The coefficient of noise
and in the insulation pads placed in the upper cavities reduction represents the average coefficient of acoustical
of the deck. absorption of an assembly composed of perforated
steel deck, fiberglass insulation pads (AF-110), and wood
The amount of reduction, known as the noise fiber panels used as roofing material for sound waves
reduction coefficient (NRC), depends upon the size, of 250, 500, 1 000 and 2 000 Hz.
number and spacing of the holes, as well as the
configuration of the deck and the acoustical material
used. All of Canams acoustical deck profiles are supplied
with fiberglass insulation (AF-110) strips which assist NOISE REDUCTION COEFFICIENTS
in absorbing sound. The insulation strips are generally P-3615 P-2436
put in place by the same contractor who installs the FREQUENCY P-3606 P-2404
roofing materials in order to avoid exposure to bad 250 Hz 0.55 0.53
weather and loss of acoustical properties.
500 Hz 0.92 0.93
The noise reduction coefficient affects only the 1 000 Hz 1.05 0.99
room below the deck because of the reduction in 2 000 Hz 0.53 0.45
reverberation. This must not be mistaken with the sound NRC 0.75 0.70
transmission coefficient (STC), which measures the

Roofing material by others

Acoustical insulation material (AF-110)


supplied in bundles by Canam is generally
put in place by the contractor who installs
the roofing material

Perforations in web elements


of steel deck to decrease
sound reverberation

33
CANAM DECK CERTIFICATION

FACTORY MUTUAL (FM)


Canam has Factory Mutual (FM) Research P-3615 & P-3606 FM MAXIMUM SPANS
Corporations approval of steel deck profiles P-3606 and NOMINAL THICKNESS SPAN*
Type
P-3615 according to FMs standard 4451. This approval (mm) (in.) (mm) (ft.-in.)
is based on a maximum deflection produced by a worker
22 0.76 0.030 1 829 6-0
moving on the roof. This is to ensure that the roofing
membranes will not be damaged and will remain 20 0.91 0.036 1 981 6-6
waterproof. Thus, there will be a maximum span for each 18 1.21 0.048 2 251 7-5
deck thickness and the deck will be used at least in
double span. 16 1.52 0.060 2 489 8-2

* At least double span condition.

UNDERWRITERS LABORATORIES OF CANADA (ULC)


Canams galvanized steel deck profiles P-3615, It shows the possible time ratings assigned to the speci-
P-3606, P-2436, P-2404, P-3623 and P-2432 are fied design assemblies in hours. Refer to the most recent
generically approved by Underwriters Laboratories of ULC Fire Resistance Directory for fire ratings with
Canada (ULC). The following table is presented only as necessary construction assembly details.
information to summarize Canam steel deck certification.

ROOF AND FLOOR DECK FIRE RESISTANCE RATINGS


Concrete Thickness Hourly Ratings
Deck U.L.C. Spray-on
Above Steel Deck* for Restrained
Profile Design No. Fire-proofing
(mm) (in.) Assembly
F701 Yes 65 2 1/ 2 2
F808 Yes 65 2 1/ 2 3
F809 Yes 65 2 1/ 2 2
F811 Yes 65 2 1/ 2 2
F817 Yes N/A N/A 1 1/ 2, 2, 3
F818 Yes N/A N/A 1
89 3 1/ 2 3/ 4, 1
Non
89 3 1/ 2 3/ 4, 1
Composite F904** No
102 4 1 1/ 2

114 4 1/ 2 2
P-3615 83 3 1/ 4 1
& 100 4 1 1/ 2
F906 No
P-3606 114 4 1/ 2 2
140 5 1/ 2 3
83 3 1/ 4 1
F910 No 100 4 1 1/ 2
114 4 1/ 2 2
F817 Yes N/A N/A 1 1/ 2, 2, 3
F818 Yes N/A N/A 1
83 3 1/ 4 1
Composite
100 4 1 1/ 2
F906 No
114 4 1/ 2 2
140 5 1/ 2 3

34
CANAM DECK CERTIFICATION
ROOF AND FLOOR DECK FIRE RESISTANCE RATINGS (CONTINUED)
Concrete Thickness Hourly Ratings
Deck U.L.C. Spray-on
Above Steel Deck* for Restrained
Profile Design No. Fire-proofing
(mm) (in.) Assembly
P-2436 F701 Yes 65 2 1/ 2 2
Non
& F817 Yes N/A N/A 1 1/ 2, 2, 3
Composite
P-2404 F818 Yes N/A N/A 1
F817 Yes N/A N/A 1 1/ 2, 2, 3
F818 Yes N/A N/A 1
89 3 1/ 2 3/ 4, 1
89 3 1/ 2 3/ 4, 1
F904** No
P-3623 Composite 102 4 1 1/ 2

114 4 1/ 2 2
83 3 1/ 4 1
100 4 1 1/ 2
F906 No
114 4 1/ 2 2
140 5 1/ 2 3
F817 Yes N/A N/A 1 1/ 2, 2, 3
F818 Yes N/A N/A 1
83 3 1/ 4 1
100 4 1 1/ 2
Non F906 No
114 4 1/ 2 2
Composite
140 5 1/ 2 3
83 3 1/ 4 1
F910 No 100 4 1 1/ 2
P-2432
114 4 1/ 2 2
F701 Yes 65 2 1/ 2 2
F817 Yes N/A N/A 1 1/ 2, 2, 3
F818 Yes N/A N/A 1
Composite 89 3 1/ 2 3/ 4, 1
89 3 1/ 2 3/ 4, 1
F904** No
102 4 1 1/ 2

114 4 1/ 2 2

* Normal weight concrete.


** Allowable loading is to be calculated on the basis of non-composite design.
N/A Not applicable

35
DIAPHRAGM
The steel deck sheets used for roofs and floors 2004. The manual contains shear diaphragm capacity
provide support for gravity loads between the joists or tables for different attachments to the structure such
beams. Once installed, these sheets can also be used as welds, screws, and nails; with welds or screws as
as a horizontal brace and therefore the steel deck works side-lap attachments. These tables cover roof deck and
as a diaphragm. The fluted deck is the equivalent of floor deck with and without a concrete cover.
a beam web with the flanges usually formed by the
The values shown in those tables are the nominal
perimeter structural members. The secondary elements
shear strength of the diaphragm and must be multiplied
are used to strengthen the web consisting of fluted deck.
by a performance factor () to be compared with applied
As in standard beams, the web elements must be
forces calculated according to a limit state code. In the
attached to the perimeter members to assure transfer of
case of forces calculated according to CAN/CSA-S136-01
the shear forces and the perimeter members must be
and CAN/CSA-S16-01, the performance factor for
attached, to each other to form a continuous flange, and
strength of steel deck diaphragm to be applied to the
to the vertical bracing system.
values shown in the SDI 3rd edition of the Diaphragm
In October 1991, the Canadian Sheet Steel Building Design Manual is equal to 0.5 which is different than what
Institute published a brochure entitled Design of Steel is shown in the header of tables published by the SDI.
Deck Diaphragms (CSSBI B13-91). It includes tables The performance factor shown for panel buckling at the
of diaphragm shear capacity for metal deck similar to bottom of the SDI table pages is 0.80 while the one to be
Canams P-3615, and P-2436 profiles, for different used in Canada is 0.75.
thicknesses, spacings, patterns and types of structural
In summary, when using the tables of the 3rd edition
attachments.
of the Diaphragm Design Manual published by the SDI,
In the United States, the Steel Deck Institute the minimum of two values, 0.50 times the Nominal Shear
compiled results from a series of tests carried out in Strength and 0.75 times the Nominal Shear due to Panel
the laboratories at the University of West Virginia. The Buckling, is the controlling limit state for shear capacity of
results of these tests were compiled to provide a theory steel deck diaphragm calculated according to the
on steel deck diaphragm leading to the publication Canadian Building Code of 1995.
titled Diaphragm Design Manual. The Steel Deck Institute
The resistance and rigidity of this bracing method
published the 3rd edition of this manual at the end of
depends upon the geometry as well as the frequency and
type of attachment used on the structural
elements and side lap joints of the steel
deck sheets. This information must be
clearly specified on the consultants
drawings so that the cost, material and
installation reflect the project engineers
design.

36
BUSINESS UNITS & INTERNET ADDRESSES

www.canamgroup.ws

www.canam.ws www.canam.ws www.hambro.ws www.murox.ws

www.solicor.ws www.structalstructure.ws www.structalbridge.ws www.technyx.ws

PUBLICATIONS TECHNICAL QUESTIONS


JOIST CATALOG JOIST: joist@canam.ws
STEEL DECK STEEL DECK: steeldeck@canam.ws
PURLINS AND GIRTS GIRTS: coldformed@canam.ws
SPECIFICATION GUIDE - JOIST GIRDERS GIRDERS: joistgirder@canam.ws

WELDING
CANADIAN

BUREAU

AP
PR O VAL

Factory Mutual Canadian Sheet Steel Deck International Canadian Canadian Association de Underwriters Underwriters American Steel Joist Steel Plus
System Steel Building Institute Conference of Welding Institute of Steel la construction Laboratories Laboratories Institute of Steel Institute Network
Institute Building Officials Bureau Construction du Qu bec of Canada Inc. Construction inc.
www.fmglobal.com www.cssbi.ca www.sdi.org www.iccsafe.org www.cwbgroup.com www.cisc.ca www.acq.org www.ulc.ca www.ul.com www.aisc.org www.steeljoist.org www.steelplus.com

37
www.canam.ws Minnesota Texas
14481 Fairway Drive 210 Silentbluff Drive
Canada United States Eden Prairie, Minnesota 55344 San Antonio, Texas 78216
Management, Sales Offices Plants Telephone: (952) 475-9165 Telephone: (210) 495-0105
and Plants Maryland Fax: (952) 475-2710 Fax: (210) 495-0141
Head Office and Plant - SJI, AISC (1) New York Virginia
Quebec, Head Office 4010 Clay Street, P.O. Box C-285 139 Hawthorne Way 11008 Blake Lane
11505, 1re Avenue, bureau 500 Point of Rocks, Maryland 21777-0285 Chittenango, New York 13037-1010 Bealeton, Virginia 22712
Ville de Saint-Georges, Beauce Telephone: (301) 874-5141 Telephone: (315) 687-5870 Telephone: (540) 439-1475
(Qubec) G5Y 7X3 Toll-free: 1-800-638-4293 Fax: (315) 687-3701 Fax: (540) 439-1476
Telephone: (418) 228-8031 Fax: (301) 874-5685
Toll-free: 1-877-499-6049 Ohio Washington
Florida 30 Hill Road South 240 N.W. Gilman Blvd., Suite G
Fax: (418) 227-5424 Plant and Sales Office - SJI, AISC (1) Pickerington, Ohio 43147 Issaquah, Washington 98027
Head Office, Plant and Sales Office 140 South Ellis Road Telephone: (614) 920-0949 Telephone: (425) 392-2935
ISO 9001:2000, SJI, AISC, CWB(1) Jacksonville, Florida 32254 Fax: (614) 920-0937 Fax: (425) 392-3149
115, boulevard Canam Nord Telephone: (904) 781-0898
Saint-Gdon, Beauce (Qubec) G0M 1T0 Toll-free: 1-888-781-0898 Oregon
Telephone: (418) 582-3331 Fax: (904) 781-2004 2081 Holcomb Springs Road
Toll-free: 1-888-849-5910 Gold Hill, Oregon 97525
Missouri (1) Certification:
Fax: (418) 582-3381 Telephone: (541) 855-9057
Plant and Sales Office - SJI, AISC (1) Fax: (541) 855-2027
Plant - ISO 9001:2000, CWB(1) 2000 West Main Street AISC = American Institute of Steel Construction
200, boulevard Industriel Washington, Missouri 63090-1008 Pennsylvania CISC = Canadian Institute of Steel Construction
Boucherville (Qubec) J4B 2X4 Telephone: (636) 239-6716 3280 St. Andrews Drive
Telephone: (450) 641-2820 Fax: (636) 239-4135 Chambersburg, Pennsylvania 17201 CWB = Canadian Welding Bureau
Toll-free: 1-800-463-1582 Telephone: (717) 263-7432 IAS = International Accreditation Service
Fax: (450) 641-3132 Washington Fax: (717) 263-7542
Plant and Sales Office - SJI, IAS(1) ISO = International Organization
Plant and Sales Office 2002 Morgan Road 1012 Hampstead Road for Standardization
ISO 9001:2000, AISC, CWB, CISC(1) Sunnyside, Washington 98944 Wynnewood, Pennsylvania 19096
807, rue Marshall Telephone: (509) 837-7008 Telephone: (610) 896-4790 SJI = Steel Joist Institute
Laval (Qubec) H7S 1J9 Toll-free: 1-800-359-7308 Fax: (610) 896-4815
Telephone: (514) 337-8031 Fax: (509) 839-0383
Toll-free: 1-800-361-3966
Fax: (450) 663-5800 Sales Offices
Plant California
125, rue du Parc 388 La Purisma Way
St-Joseph-de-Beauce (Qubec) G0S 2V0 Oceanside, California 92057
Telephone: (418) 397-1000 Telephone: (760) 439-5339
Fax: (418) 397-1001 Fax: (760) 269-3403
Alberta Florida
Plant and Sales Office - SJI, CWB(1) 553 Waterside Drive
323 - 53 rd Avenue S.E. Hypoluxo, Florida 33462
Calgary, Alberta T2H 0N2 Telephone: (561) 547-7469 www.structalstructure.ws
Telephone: (403) 252-7591 Fax (561) 540-2571
Toll-free: 1-866-203-2001
Plant and Sales Office, Sales Office, United States
Illinois Canada Maryland
Fax: (403) 253-7708 613 Sheffield Lane
ISO 9001:2000, AISC, CWB(1) 4010 Clay Street, P.O. Box C-285
Ontario Bolingbrook, Illinois 60440 Point of Rocks, Maryland 21777-0285
Telephone: (630) 427-1003 1445, rue du Grand Tronc
Plant and Sales Office - SJI, CWB(1) Qubec (Qubec) G1N 4G1 Telephone: (301) 874-5141
1739 Drew Road Fax: (630) 427-9046 Toll-free: 1-800-638-4293
Telephone: (418) 683-2561
Mississauga, Ontario L5S 1J5 540 Truman Street Toll-free: 1-877-304-2561 Fax: (301) 874-5075
Telephone: (905) 671-3460 Bolingbrook, Illinois 60440 Fax: (418) 688-8512
Toll-free: 1-800-871-8876 Telephone: (630) 961-5944
Fax: (905) 671-3924 Fax: (630) 961-5945
Sales Offices Indiana
British Columbia 5605 Hidden Valley Road
95 Schooner Street Russiaville, Indiana 46979
Coquitlam, British Columbia V3K 7A8 Telephone: (765) 883-1135
Toll-free: 1-866-203-2001 Fax: (765) 883-1138
Fax: (604) 523-2181
2219 Canyon Creek Dr.
New Brunswick Lafayette, Indiana 47909
95 Foundry Street Telephone: (765) 471-7300
Heritage Court, Suite 417 Fax: (765) 471-7303
Moncton, New Brunswick E1C 5H7 www.technyx.ws
Telephone: (506) 857-3164 Kansas Brasov, Romania
14521 West 86th Terrace Business Offices
Fax: (506) 857-3253 Quebec, Canada Ionescu Crum Street No 9
Lenexa, Kansas 66215 Brasov 500446, Romania
Quebec Telephone: (913) 384-9809 270, chemin Du Tremblay
200, boulevard Industriel Boucherville (Qubec) J4B 5X9 Telephone: (40 268) 31 43 73
Fax: (913) 384-9816 Fax: (40 268) 32 78 63
Boucherville (Qubec) J4B 2X4 Telephone: (450) 641-4000
Telephone: (450) 641-8770 Maryland Toll-free: 1-866-506-4000 Kolkata, India
Toll-free: 1-800-463-1582 P.O. Box 296 Fax: (450) 641-4001 GN 37/B, Sector V
Fax: (450) 641-8769 Phoenix, Maryland 21131-0296
Salt Lake, Kolkata
Telephone: (410) 472-4327
Engineering and Credit Office, Corporate 700 091 India
Fax: (410) 472-4827
270, chemin Du Tremblay Telephone: (91 33) 23 57 58 65
Boucherville (Qubec) J4B 5X9 Massachusetts Fax: (91 33) 23 57 59 14
Telephone: (450) 641-4000 50 Eastman Street
Toll-free: 1-866-506-4000 Easton, Massachusetts 02334-1245
Fax: (450) 641-4001 Telephone: (508) 238-4500
Fax: (508) 238-8253

38
Better Building Solutions

Printed in Canada 02/2006

Saint-Gdon
115, boulevard Canam Nord
Saint-Gdon, Beauce
(Qubec) Canada G0M 1T0
Telephone: (418) 582-3331
Toll-free: 1-888-849-5910
Fax: (418) 582-3381

www.canam.ws

Você também pode gostar