SECTION J-1: SCHEDULE OF WATERPROOFING

1.0 GENERAL
1.1 WORK INCKUDED: This section deals with waterproofing and surface
treatment of concrete structures, as shown on the drawings and as specified
herein, with special reference to enclosures due to contain liquid of quality
sufficient to create hydrostatic pressure. This comprises the concrete slab floors,
interior walls, and all areas indicated in the plan.
1.2 QUALITY ASSURANCE:
a. QUALIFICATION OF INSTALLER: Minimum of one person, who is
systematically knowledgeable in the installation of the itemized products,
must always be present in finishing of this portion of the work. He shall
direct all work done under this section.
b. MANUFACTURERS CERTIFICATION. Before proceeding to the
installation of the work of this section, a representative of the manufacturer
of the waterproofing materials used intend to visit the job location to
examine and to make clear
c. That the surface to which the waterproofing was applied were in state
appropriate for that application
d. That the materials mounted conformed in and aligned with the
requirement of this section of the specifications
e. That the materials were installed in complete agreement with the
manufacturers recent commendations
1.3 PRODUCT HANDLING:
a. PROTECTION: Safety measures must be functioned to guard
waterproofing constituents earlier, throughout, and after installation and to
protect the installed work and materials of all other trades.
b. REPLACEMENTS: In the incident of damage, necessary maintenances
and replacements must be made, subject to the approval of the Architect
and at no additional cost to the Owner.
2.0 PRODUCT
2.1 Liquid Cold Applied Membrane Waterproofing for Toilet & shower, ledges, and
kitchen floor: SONNEBORN HLM-5000 liquid cold applied waterproofing
membrane system
2.2 Elastomeric Waterproofing system with reinforced fiberglass mesh for
concrete gutters, property walls or firewalls shall be BIRD & SON
ELASTOMERIC WATERPROOFING CHEMICAL
2.3 Concrete primmer / binder for concrete surface with one layer Fiberglass
mesh
2.4 Elastomeric Waterproofing Chemical

3.0 EXECUTION
a. The concrete surface shall be troweled, even, strong, dry, clean and free of
rubbish, loose or foreign materials, without any projections. Cants shall be
installed in the angle formed by the floor and adjoining wall.
b. For roof deck, deck shall be appropriately graded to drain water freely into
gutters and downspouts. Set up drainage connection to permit the free flow of
water. Install cants in the angle formed by gutter and vertical surfaces. Complete
the setting up of metal fitting and similar works prior to start of rooting work.
c. All areas to receive mineral polyhand shall be wood troweled smooth, firm dry,
dry and clean of rubbish, loose or foreign materials and obstruction. All slants
and turns should be rounded off, collisions flattened and holes occupied and
leveled. If there are blisters, they shall be cross cut and patched. Remove all
nails, stone and any other objects then sweep off all dust.
d. All areas to received Sonneborn HLM 5000 shall be lightly steel troweled to
fairy smooth finish. New concrete must be properly water cured atleast 14 days
and surfaces must be dry. All dust, dirt and other contaminants must be remove
and cleaned.
e. Concrete to receive Vandex treatments have a clean surface and an open
capillary system to ensure chemical penetration and maximum bonding. Surfaces
to be waterproofed shall be examined for structural defects, and unacceptable
cinditions reported in writing to the Architect. Remove all protrusions, work back
to sound concrete, chiseling out any honeycombed or damages areas.
Construction joints and shrinkage cracks exceeding 0.3 millimeters shall be
routed out to a minimum depth of 20 millimeters. Formite holes should be
roughened.
Water leakage must be stopped according to Vandex Plugging Specification
Remove all cement laitance, from release agent, curing compound, loose
particles etc. by means of light, wet and ry sand blasting, a high-pressure water
jet or wire brush.
Clean all chiseled out areas, form-tie holes etc. and prewater until the concrete is
saturated. Then slurry coat the repair with Vamdex Super or Vandex BB 75.
While the slurry coat is still green, fill the areas flush with surface using a vandex
mortar.
Prior to applyingVandex, rinse carefully all the surfaces to be waterproofed
Vandex is applied; the surfaces should be damp but not wet.
Any surface water on horizontal surfaces must be removed.
The Entire surface shall be dampened out with clean water in order to cure the
surface the day following the final coating of Vandex Super. The surface shall be
jept damp for at least five days.
h. All surface to be painted with BIRD & SON elastomeric waterproofing chemical must
be free from dust, oil, wax, chalky or blistering paints and other foreign matters that
could adversely neutralizer prior to painting.