Notes

1. Dimensions in millimetres unless otherwise stated.

A
-

Key to symbols
Waterproofing
layer to be applied

1255
90
Indicative location of access cover

Section A
1:100 -

Typical Section

1565

100
Reference drawings

60x60x5 SHS, 60x60x5 SHS,


capped at both ends capped at both ends

350
Plan 60x60x6 Equal Angle 60x60x6 Equal Angle
Scale: 1:20

1255

355
Rubber watertight seal
0 1m 2m
1:20
@A1
0 0.5m 1m
1:10
@A1

350
60x60x6 Equal Angle
1685 271 271 271

100
EL. 199.98 mAOD

106 271 271 106 M20 bolts secured with P1 13/10/15 CJE Preliminary Issue SC AK
Gate Frame hilti fixing glue or similar Rev Date Drawn Description Chkd Appd
Waterproof sealant to be applied Scale: 1:10 into concrete pillars
after gate frame installation
Secure latch
1255

Rubber watertight seal Demeter House


Station Road
Cambridge, CB1 2RS
United Kingdom
T +44 (0)1223 463500
F +44 (0)1223 461007
W www.mottmac.com
40x40x6 Equal Angle 40x40x6 Equal Angle

Client
Severn Trent Water PLC
Severn Trent Centre
40x40x6 Equal Angle 40x40x6 Equal Angle
84 2 St. John's Street
Coventry
1235

1235
5mm thick flat 5mm thick flat CV1 2LZ
Title
Tittesworth Reservoir
40x40x6 Equal Angle Dam Crest
Elevation A
Flood Gate at Access Bridge
1:20 -

Typical Elevation
40x40x6 Equal Angle 40x40x6 Equal Angle

Designed S. Court Eng check S. Court


Drawn C. J. Easson Coordination -
805 760 Dwg check S. Court Approved A. Kirby
Scale at A1 Status Rev
Left Gate Right Gate
Mott MacDonald Scale: 1:10 Scale: 1:10
As Shown PRE P1
Drawing Number
This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose.
We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties. MMD-344035-WCD-DR-00-PL-400
P:\Cambridge\Demeter\EVT\Projects\314557 - Tittesworth\06. CAD\Working Drawings\MMD-344035-WCD-DR-00-PL-400_Flood Gate - Details and