(1) Design Condition

Minimum Tensile Strength : Fu = 400 [N/mm2]


Minimum Yield Strength : Fy = 235 [N/mm2]
: Fyp = 235 [N/mm2]

Modulus of Elasticity :E = 200000 [N/mm2]

Grade of Anchor Bolt


Tensile Strength : ASTM A307 : FuB = 400 [N/mm2]

Concrete
Compressive Strength : f'c = 28 [N/mm2]
gx
T/N
g
gz

T/N

beff
TensionForceDiagram
TYPE - 1

beff
2*g
T/N
g
gz

2*g
T/N

gx

TensionForceDiagram
TYPE - 2

Figure 1.0 Dimensions on Base Plate


(2) Sybmols

Ab : Nominal Unthreaded body area of anchor bolt


Ac : Area of Steel Column
A1 : Base plate area ( B * N )
A2 : Area of Pedestal (px*py)
B : Base plate dimension parallel to column flange width
bfc : Column flange width
dc : Column depth
db : Anchor bolt diameter (mm)
Fyc : Column minimum yield strength
Fyp : Base plate minimum yield strength
L : Critical cantilever length of base plate
N : Base plate dimension parallel to column depth
nb : Total number of anchor bolt in the connection
px : Pedestal dimension parallel to column flange width
py : Pedestal dimension parallel to column depth
Ta : Ductile design tension capacity per bolt
tp : Thickness of base plate
Va : Ductile design shear capacity per bolt

(3) Allowable Strength


General Interaction of Strength and Combined Tension & Shear
Pu Pn/ --- Compression
Tu Tn/ --- Tension
Vu Vn/ --- Shear
Tu / (Tn/) + Vu / (Vn/) 1.2 (Reference : Section D.7 of ACI 318-11)
Note : Friction between the base plate and the grout will resist shear forces. Therefore
if Pu* > Vu, shear check of anchor bolt can be ignored.
Where : = 0.55 (coefficient of friction for steel on grout)

Allowable Strength
Pn/ = Min. Pi i = 1, 2 [kN]
Tn/ = Min. Ti i = 1, 2 [kN]
Vn/ = V1 [kN]

A) COMPRESSION

A.1) Axial Load Capacity (see Section 3.1.1 of AISC Design Guide 1)
P1 = ( 0.85 * f'c * A1 * (A2/A1)1/2 ) / [kN]
= 2.50 (A2/A1) 2
A.2) Base Plate Bending (see Section 3.1.2 of AISC Design Guide 1)
P2 = tp2 * Fyp * B * N / (( 2 * L2 ) * ) [kN]
= 1.67
L= max m = ( N - 0.95 * dc ) / 2 [mm]
n = ( B - 0.80 * bfc ) / 2 [mm]
n' = * ( dc * bfc )1/2 / 4 [mm]
= 1.0

B) TENSION
B.1) Anchor Bolt
T1 = nb*0.75 * Ab *FuB / [kN]
= 2.0 , nb = 4
db T1/
[mm] [kN]
M16 29.7
M20 42.8
M25 76.1
M32 118.8
Note: Concrete Breakout Strength due to tension loading can be ignored if pedestal
detail is according to drawing no. 1TA-NC-CXSV2-0002.

B.2) Base Plate Bending (see Section 4.5 of AISC Design Guide 1)
(Refer to Figure 1.0)
T2 = nb * Fyp * beff * tp2 / (( 4 * g ) * ) [kN] (For Type - 1)
T2 = 2*nb * Fyp * beff * tp2 / (( 3 * g ) * ) [kN] (For Type - 2)
= 1.67

C) SHEAR

C.1) Anchor Bolt


V1 = 0.75 * Ab *FuB / [kN]
= 2.0
nb = 4
db V1/
[mm] [kN]
M16 17.8
M20 25.7
M25 45.6
M32 71.3
Note: Concrete Breakout and Concrete Pyrout Strength due to shear loading shall
be checked according to ACI 318M-11 Appendix D.