Você está na página 1de 3

MATERIAL TEST REPORT

ABN 90 706 021 096


ACN 079 834 058
Job No: MT17-00649 / 1 MARINE INSPECTION SERVICE Pty Ltd

Issued: 22 May 2017 Order No: 9910 - 10605


8 Egmont Road,
Client: G F ENGINEERING PTY LTD Henderson WA 6166
NAVAL BASE, Western Australia
Phone: 08 9437 6155
Attention: Syed Rahman Fax: 08 9437 6022

Description: The machining and mechanical testing of one only butt welded
Welder / Procedure Qualification test plate.
Identification: WPQR GF186 STT / FCAW 2G
Welder: K. Hawtin (WR13)
Material Specification: AS/NZS3678 Grade 350 8MM PL
Heat No: N92116
Test Specification: AS/NZS3992-2015 (AS1210 Class 1.), AS/NZS1554.1-2014, Category SP.
Samples received: 18/05/2017

See Attached MIS Radiographic Report. (NATA Lab No: 4754.)

Specimen Type: Reduced Section , Weld Reinforcement Removed.

30.0 6.97 134 640 Parent Complies

30.0 7.15 135 629 Parent Complies

Equipment Type: Transverse Guided Bend, Roller Support, Angle 180.

30 x 8 24 No Defects Apparent Complies

30 x 8 24 No Defects Apparent Complies

Equipment Type: Transverse Guided Bend, Roller Support, Angle 180.

30 x 8 24 2.8mm Fissure Complies

30 x 8 24 No Defects Apparent Complies

MIS Job: MT17-00649 / 1 This service has been delivered under the controls established by a QMS approved quality management Page 1 of 2
system that conforms with ISO9001. Under QMS certificate number 002-92314-Q.
Please note that following the completion of testing MIS Pty Ltd will retain test samples for a period of 14 days, unless prior written arrangements have been made with MIS.
Note that this report is based on the products supplied to MIS Pty Ltd and it remains the responsibility of the client to ensure the samples presented are representative of
the whole batch. Reproduction of this report, other than in it's entirety, must be approved by MIS.
MATERIAL TEST REPORT
Job No: MT17-00649 / 1 ABN 90 706 021 096
ACN 079 834 058

Specimen Examined at X20 Magnification,

10% Nital 0.1mm Undercut Complies

10% Nital 0.2mm Undercut Complies

NOTE: Graticule Scale = 1mm per Division

MACRO 1

MACRO 2

This document is issued in acccordance with NATA's


accreditation requirements. Accredited for
compliance with ISO/IEC 17025.
Wayne Cridland
Mechanical Testing Officer NATA Accredited Laboratory 12425.

MIS Job: MT17-00649 / 1 This service has been delivered under the controls established by a QMS approved quality management Page 2 of 2
system that conforms with ISO9001. Under QMS certificate number 002-92314-Q.
Please note that following the completion of testing MIS Pty Ltd will retain test samples for a period of 14 days, unless prior written arrangements have been made with MIS.
Note that this report is based on the products supplied to MIS Pty Ltd and it remains the responsibility of the client to ensure the samples presented are representative of
the whole batch. Reproduction of this report, other than in it's entirety, must be approved by MIS.
MIS Job N: MT17-00649/1
8 Egmont Rd Henderson, WA 6166
Tel. (08) 9437 6155 Date of Test: 18/05/2017
Fax. (08) 9437 6022
Page N: 1 of 1

Radiographic Inspection Report


Client: G F Engineering Pty Ltd Client Order N: 9910-10605
Address: Naval Base, Western Australia Contact: Bodie Logan
Project: Welder/Procedure Qualification
Heat Treatment: N/A Test Location: MIS Workshop
Surface Condition: As Welded
Material Type: AS 3678 Grade 350
MIS Procedure N: TP02-1
Technique Film IQI (Placement) Radiation Source: X-Ray
Density Range: 2.0 4.0
XR2/S T200 10 FE EN (S)
Film Screen: Pb 0.027mm
Construction Code: AS 3992-2015, AS 1554.1-2014 (SP)
Acceptance Criteria: AS 4037-1999 (CL1), AS 1554.1-2014 (SP)
Inspection Specification: AS 2177-2006/AS 2314-2006
Items / Positions Examined
Identification Area Interpretation Sens % Result

WPQR: GF186 0-300 SMG, GPs 1.6 C


Welder: K. Hawtin (WR13)
Process: STT/FCAW
Position: 2G
Size: 8mm Plate

Test Restrictions

No Restrictions

Abbreviation List
DNC Does not Comply SRC Root Concavity A Absence of Discontinuities GP Gas Pore C Complies
SGC Shrinkage Groove SSP Spatter IT Tungsten Inclusion PG Group Porosity KL Longitudinal Crack
SMG Grind Mark SUC Undercut LP Incomplete Root Penetration PL Linear Porosity KC Crater Crack
SMT Tool Mark SXP Excess Penetration SGI Incompletely Filled Groove PU Uniform Porosity KE Edge Crack
LS Lack of Side Fusion CP Crater Pipe LI Lack of Inter-run Fusion WH Wormhole KT Transverse Crack
LR Lack of Root Fusion PD Processing Defect EC Elongated Cavity IL Linear Inclusion IN Inclusion

Technicians: C. Murphy, D. Richman


Date Signed: 19/05/2017
Viewed By: T. McLoughlin
Signatory: J. Cook

Signature:

DOC: MS015 Rev 6