Você está na página 1de 1

Project: BOP

JOB SAFET ANALYSIS


Ref No.:

Rev No.:
Radiography Testing
Page: 1 of 1

Reviewed
Prepared by: HSE - ELB
by:
Approved
Date:
by:

Step Description of Task Control Measures/


Hazard Responsible
No. Step Preventive Measures

1 NDT -Radiography Radiation Proper PPE.


Radioactive Cordoning of Area (Isolation by time).
contamination Signboards.
Certified Radiographer Contractor.
Injuries / Radiation Monitors are fit for purpose (In
Radioactive Calibration).
effects on Only classified workers allowed in work
workers health area during exposure of source.
PA announcement prior to start.
Dose rate not exceed 7.5 micro sieverts
per hr. at barriers.
Emergency equipment readily available on
site.
No eating/drinking in work area.
Radiation source to be returned
immediately to be approved holding area
when not in use.
RT Procedure approved by Company.