ELECTRICAL CIRCUIT TESTING

The LPG solenoid valve opens when the starter switch key is in S or M position and the pressure acting on the oil pressure
switch is higher than 0.3 kgf/cm2 (4.3 psi) [29.4 kPa]. For this reason, measure the resistance (12 V ) of the solenoid valve
with a pressure of 0.3 kgf/cm2 (4.3 psi) [29.4 kPa] applied to the oil pressure switch to see if the LP gas supply line is in good
condition.

59