Escolar Documentos
Profissional Documentos
Cultura Documentos
Jenny Burridge
MA CEng MICE MIStructE
Head of Structural Engineering
Structural Eurocodes
General
Basis of design
Materials
Durability and cover to reinforcement
Structural analysis
Ultimate limit state
Serviceability limit state
Detailing of reinforcement and prestressing tendons General
Detailing of member and particular rules
Additional rules for precast concrete elements and structures
Lightweight aggregated concrete structures
Plain and lightly reinforced concrete structures
Eurocode 2 - Annexes
N.A.
BS EN 206-1 NSCS
Specifying BS EN 1992
Concrete Design of concrete structures
BS EN 10080
Part 1-1: General & buildings Reinforcing
BS 8500 Part 1-2: Fire design Steels
Specifying
Part 2: Bridges
Concrete
Part 3: Liquid retaining BS 4449
Reinforcing
Steels
NSCS Guidance:
1 Basic
2 Ordinary
3 Plain
4 Special Visual Concrete
Labour and Material (Peri)
24%
58%
18%
Rationalisation of Reinforcement
Reinforcement
Reinforcement
EC2 does not cover the use of plain or mild steel reinforcement
Principles and Rules are given for deformed bars, decoiled rods,
welded fabric and lattice girders.
Properties of reinforcement
(Annex C)
Product form Bars and de-coiled rods Wire Fabrics
Class A B C A B C
The UK has chosen a maximum value of characteristic yield strength, fyk, = 600 MPa,
but 500 MPa is the value assumed in BS 4449 and 4483 for normal supply.
Extract BS 8666
www.ukcares.co.uk
www.uk-bar.org
Reinforcement supply
Medium
33,51,56,63,64 & 99?
High
Bending
Minimum Bends
Scope:
Part 1-2 Structural fire design gives several methods for fire engineering
Tabulated data for various elements is given in section 5
Reinforcement cover
Axis distance, a, to centre of bar
a = c + m/2 + l
Axis
a Distance
Axis distance, a
Fire protection
Procurement
Practicalities
12m maximum length H20 to H40
(12m H40 = 18 stone/ 118Kg)
Health & safety
9m maximum length H16 & H12
6m maximum length H10 & H8
Transport
Fixing
Control of Cracking
EC2: Cl. 7.3
The minimum area of reinforcement for slabs (and beams) is given by:
0.26 fctm bt d
A s,min 0.0013 b t d
fyk
Note: For cracking due to restraint use only max bar size
Spacing of bars
EC2: Cl. 8.2
250
a) 45 90 c) h > 250 mm
Direction of concreting
Direction of concreting
300
h h
However:
(2 3 5) 0.7
lb,min > max(0.3lb,rqd ; 10, 100mm)
Alpha values
EC2: Table 8.2
l0 = 1 2 3 5 6 lb,rqd l0,min
Alpha values
EC2: Table 8.2 Concise: 11.4.2
Table 8.2 - Cd & K factors
EC2: Figure 8.3 Concise: Figure 11.3
Arrangement of Laps
EC2: Cl. 8.7.2, Fig 8.7
Transverse Reinforcement
Anchorage of bars
Lapping of bars
F tan
F F
F tan
F/2 F/2
If more than 50% of the reinforcement is lapped at one point and the
distance between adjacent laps at a section is 10 transverse bars should
be formed by links or U bars anchored into the body of the section.
The transverse reinforcement provided as above should be positioned at
the outer sections of the lap as shown below.
Ast /2
Ast /2
l 0 /3
l 0 /3
150 mm F
Fs s
l0
Beams
EC2: Cl. 9.2
As,min = 0,26 (fctm/fyk)btd but 0,0013btd
As,max = 0,04 Ac
Section at supports should be designed for a
hogging moment 0,25 max. span moment
Any design compression reinforcement () should be
held by transverse reinforcement with spacing 15
Beams
EC2: Cl. 9.2
V s V
z d z d
x x
d d
av av
Shear Design
EC2: Cl. 6.2.3
z d
x
s V
z d
x
Curtailment of reinforcement
EC2: Cl. 9.2.1.3, Fig 9.2
Envelope of (M Ed /z +N Ed )
lbd
Acting tensile force lbd
Ftd
al
al
lbd
Ftd
lbd lbd
Shift rule
lbd lbd
Anchorage of Bottom
Reinforcement at End Supports
EC2: Cl. 9.2.1.4
Tensile Force Envelope
al
Supporting Reinforcement at
Indirect Supports
EC2: Cl. 9.2.5
B
A supporting beam with height h1
B supported beam with height h2 (h1 h2)
h 2 /3
h 2 /2
Plan view
Solid slabs
EC2: Cl. 9.3
Where partial fixity exists, not taken into account in design: Internal
supports: As,top 0,25As for Mmax in adjacent span
End supports: As,top 0,15As for Mmax in adjacent span
h 4b
min 12
As,min = 0,10NEd/fyd but 0,002 Ac
Columns
150mm
EC2: Cl. 9.5.3
scl,tmax
150mm
Detailing Comparisons
Detailing Comparisons
Punching Shear EC2 BS 8110
Links Clause / Values Values
Asw,min 9.4.3 (2): Link leg = 0.053 sr st Total = 0.4ud/0.87fyv
(fck)/fyk
Spacing of Links
Sr 9.4.3 (1): 0.75d 0.75d
St 9.4.3 (1): 1.5d
within 1st control perim.: 1.5d
outside 1st control perim.: 2d
Columns
Main Bars in Compression
As,min 9.5.2 (2): 0.10NEd/fyk 0.002bh 0.004 bh
As,max 9.5.2 (3): 0.04 bh 0.06 bh
Links
Min size 9.5.3 (1) 0.25 or 6 mm 0.25 or 6 mm
Scl,tmax 9.5.3 (3): min (12min; 0.6 b;240 mm) 12
9.5.3 (6): 150 mm from main bar 150 mm from main bar
How toCompendium