Você está na página 1de 76

Welcome to Mars Monitoring World

India Man in Light


We commited to see India on
TOP and best Facilties around
The World

Presentation on Best Practice for


Electrical Equipment Installation and Safety
of Product(Earthing & Protection)
Smart India and Space Programme
Smart India Mission using Satellite
To Protection our Nation using Satellite for Monitoring of
Borders (Sea,Ground and Air)
To Collect Data for Weather Monitoring for efficient use
To Collect Data for Early Warning (DisasterManagement)
Use of Satellite for Communication (Transmission & Reciving of
Data and Images
Use of Satellite for Broadcasting Radio/Television
Use of Satellite for Global Positing and information Systems
Connecting Physical devices to Control and Monitoring
Use of Satellite for Storage and Data Management
Use of Realtime Data and Event for Survilliance and Video
Monitoring.
Use of Satellite for Transportation of Public and Goods through
Surface,Sea and Air
Many More Important use of Satellite in our life.
Deep Sea P Sensor

6
Suggested real-time sea level stations
(India)

|7
Surface Currents (India)

|8
Lightning
Safety of the structure / human/ equipments
Hamen Babaji Nahi Science Chahiye
India Life can be Save from Lightning
We all may be danger if not Protected
Horrifying Losses Due To Devil Lightning
Early Warning System/Alert
Protection from Lightning Charges
Hame Jina hey Hame Jine Doo
Standards Worldwide for Lightning NFC17-102 and IEC62305-3
Make in India India
Space Programme(Smart and Economical
Topics of Presentation

Latest National Building Code 2016


Maintenance Free Earthing Arrangement as per UL 467, IEC 62561-2
Earth Enhancing Compound as per IEC 62561-7
Exothermic Weld(Fail Proof Joints) as per IEEE 837
Copper Clad Steel Replacement of GI Flat Strips as per IEEE & IEC
Surge Protection for Power and Communication Port (Suitable Integration is
also available)
Lightning Protection IS/IEC 62305 Part 1-4
NFC 17-102/UNE 211186 is in Process Incorporation in National Electric
Code Under Final Revision
Our Solutions for Best Practice
(Earthing & Protection)
Electrical Power Generation ,Transmission &
Distribution
Backup Power(DG and UPS now Solar PV Power)
Communication Equipment (Fixed or Wireless)
Security Surveillance (CCTV/Access
Controls/Networking)
Building and Infra Solutions
Launching Vechiles
Control & Montoring
Surge Protection use Recommendation
We always think about Safety of Each Life
Everybody Monitor for Human Safety
We are offering
Surge Protection Devices as IS/IEC 62305-4
Sikhana to Padega Hi Follow NBC2016
Best Earthing Practice to perform equipment well &
protects from shock (As per Latest NBC-2016)

1. Equipment Earthing
CI/GI/ Copper Plate earthing with maintenance
material
Copper/ Copper Bonded Steel Rod with
maintenance free earthing system

2. GRID Earthing
Copper Bonded Steel Rod- Best Earthing Material /
Superior in Quality / Recommended by IEEE 80, UL 467,
IEC 62561-2, IS 3043

Low carbon solid steel rod with minimum 250 micron pure
copper coating as per UL 467
Offers 4 to 5 times more working life than GI electrode
Excellent fault current carrying capacity
Exhibits same corrosion resistant property as copper
High strength of steel
A cost effective solution
Theft proof solution
Complete Earthing Arrangement

The use of Earth Enhancing Compound


complying to IEC - ..pla s a i porta t i
making grounding system much more effective.
- It retain moisture thus provide smooth path for current to flow
faster.
- Si e it has oisture rete tio properties it does t de a d
regular watering that makes the grounding system low
maintenance.
- The continuous presence of moisture provides stable Ohmic
value.
- It does t ot ashes a a ith ti e.
- It does not demand continuous presence of water to maintain
its conductivity.
Fire Accident due to electrical joint failure in
Lightning Protection & Earthing
An Arcing Fault is the flow of
current through the air between
phase conductors or phase
conductors and neutral or ground.
Concentrated radiant energy is
released at the point of arcing an a
small amount of time resulting in
Extremely High Temperature.
Earthing Connections & Joint Practices

For making earthing connections &


electrical jointing, mechanical joints are
still prevails.

Nut & Bolt, welding, clamping,


brazing

Only give 8-20% contact surface area

Gets corroded over the period of time


due to atmospheric corrosion

Contact areas of connections have voids


and gaps which cause corrosion, rust
and oxide results in early deterioration

Resistance of mechanical connections


increases with time and this alters the
conductive properties of connections
EXOTHERMIC WELDING- For all buried & permanent
connections as per IEEE 837 / NBC 2017

Main earthing wire connections shall be:


Be mechanically & electrically sound;
Be protected against damage, corrosion and vibration;
100% contact surface area is must;
Be secured at the earth electrode;
EXOTHERMIC WELDING-
Permanent Jointing solution

These cavity can be designed on


customize basis as per the type of joint
is required.

Also the dimension of the conductors


which needs to be joint in a kind of
jointing.

We are the manufacturer and can offer


any kind of joint type as mentioned
below:
Most Efficient Joint Process

It is efficient and superior to all existing surface to-surface


mechanical retention connectors.
Copper Clad Steel Solid ROD and Conductor
Surge in Systems and Result
Surge in DC Application
External/Internal Surge Source
LIGHTNING FORMATION
Safety Main It Should be Remain
(Protect your Equipment for Internal & External Surges)

The 100% of lightning energy breaks down as follows:

a) 50% of the lightning current will flow through


the ground
b) 50% of the lightning current will flow over the
connected metal parts out of the building:
about 10% to the water pipe (metal)
about 10% to the gas pipe (metal)
about 10% to the oil pipe (metal tank)
about 10% to the sewage pipe
a out % to the power suppliers i o i g feed
max. 5% or 5 kA shared across all data lines
Facts about Lightning
A strike can average 100 million volts of electricity
Current of up to 200,000 amperes
Can generate 54,000 oF
10/350MicroSec/50KA Fault Current/Discharge in
Nano Sec
Protection
Earthing Design100KA Fault Current/Joints Exothermic
/Flexible Down Conductor with Shortest Route &
Less Corner
Lightning Protection Standard use in India
(IS2309 Now IEC 62305-5)NBC2016
Working Principle Angular No Compromise with Design
Max Protection 30Mtrs from One
No Product warranty from Manufacturer
High Maintenance Require
Earthing below 10.00 Ohm
Lightning Risk Assessment Study is actually the
measure of risk of a lightning strike and probability of
damages. As Per IEC62305-2.

All these calculations are based on:


Lightning strike density in that particular area(provided byOMV i.e.Ng = 8),
Danger for people,
Occupation coefficient of structure,
Relative location of site,
Fire Risk,
Associated services,
Electrical Lines,
Lightning Protection Level,
Surge Arrestor and
Dimensions of installation.
Lightning Risk Calculation as per IEC62305-2
Ligthing Risk Calculation
Lightning Risk Calculation
Lightning Risk Calculation
Risk Assessment Calculator as per IS/IEC 62305
Air- Termination System

1. Vertical Rods- simple


shaped buildings

2. Catenary wires-
suitable for all cases

3. Meshed/ Grid
Conductors- best for
where plane/ pitch
roof surfaces
Air- Termination System Design
Protection Angle method
Mesh/ Faraday Cage Method
Rolling Sphere Method
Lightning Protection As Per NF C 17 102/UNE 211186

The ESE air terminal is a terminal which enables to generate artificially an upward leader earlier than a simple rod, with an
ionization system, in order to establish a special impact on its point. The capture of the lightning strike being faster than a
simple rod, this technology enables to benefit from larger protection areas, ensuring protection for large dimensions structures.

The generated protection radius depends on the early streamer emission value of the air terminal (t in s), its height, and the
efficiency of the protection. The protection radius ensured by this type of air terminal is 120 m (Protection level IV, height = 60
m , early streamer emission time 60s).

The NFC 17-102/UNE 211186 standard describes the installation procedure for this type of air terminal.

The installation of this type of air terminal is easy and cheaper than other technologies.

It can protect whole buildings with one E.S.E. air terminal. It enables the protection of a structure and its environment, the
protection of opened areas and well integrate in the architecture of a structure without aesthetic alteration.

1 ESE, 2 down conductors and 2 earthing systems are necessary to ensure the protection.
Early Streamer Emission Air Terminal
An active and advance technology device based on the principle of
Corona effect.

Internationally accepted technology complying standard NFC 17-102.

Active Protection not only protects the structure also protect


surroundings & open areas.

Made up of stainless steel SS-316L hence highly corrosion resistant


and long lasting.

More life due to corrosion resistant material is used.

Single installation offering maximum radius of protection of 109


meters which is very large in comparison to conventional lightning
system.

ESE air terminal is very quick in response.

Excellent, no electronic device.

Economical solution.

Easy to Install.
IEC Declaration by CENELEC for
NFC17-102
BT has confirmed that ESE National Standards would remain valid and thus BT recognized
there ould e o e ide e of o fli t et ee NF C a d IEC EN sta dards a d
consequently there is no reason, technical or otherwise, for the withdrawal of the respective
national standard.BT has requested that this standard be modified in order to cancel all
refere e to the IEC EN series, allowing the NF C sta dard to e ist, ith the
proposal of possible future migration to international level (lEC). Accordingly, it was established
that European ESE standards (France, Spain, Portugal, Slovaquia, etc.) will not
conflict with other European standards and will remain valid.
GIMELEC would draw your attention to the fact that
the ter s of refere e of NF C a d
other standards, addressing alternative terminals (NF
C , PR EN ) ere fro the
outset, er differe t. It is a fa t that NF C ,
whilst referring to ESE Technology also
comments on other standards for lightning protection
systems, particularly incorporating
faraday cage, franklin rod and catenary wire systems.
the 'camouflaging' of NF C 102 by IEC EN
and its proponents, that FRENCH STANDARD
NF C is still in full force.
ESE Installation Guidance

ESE AT with radius protection form 32 mtr to 107 mtr.

DMC Insulator .

GI/FRP Mast .

Down Conductor Copper / Copper Cadmium


Cable 70 sq. mm

Copper Bonded Ground Earthing


Safety Main It Should be Remain
(Protect your Equipment for Internal & External Surges)

The 100% of lightning energy breaks down as follows:

a) 50% of the lightning current will flow through


the ground
b) 50% of the lightning current will flow over the
connected metal parts out of the building:
about 10% to the water pipe (metal)
about 10% to the gas pipe (metal)
about 10% to the oil pipe (metal tank)
about 10% to the sewage pipe
a out % to the power suppliers i o i g feed
max. 5% or 5 kA shared across all data lines
Gel Based Cable Jointing Kit
Thimble

Joint all phase wire/ cable with the help of


crimping tools and lugs

Step 1
Separation Sheet

Fixed the separation sheet between all wires/


cables

Gel / Silicon
Step 2
Close the filled Silicon enclosure from top and
bottom , complete installation is done.

Step 3
JMV Products for Earthing & Protection
Contact Professionals for Advise
We Protect You
Use Well Engineered Electrical Safety
Solutions With Us
Contact Our Team JMV INDIA
Leader and Inspiration behind Mr. Neeraj Saini neeraj@jmv.co.in
Mr. Mahesh Chandra Manav Brand JMV HOD manav@jmv.co.in
www.jmv.co.in
Mobile -919910398999 Landline -01204590000
JMVs Clients

Você também pode gostar