Display Non- Display Pressure Sensing Range from -14.5 to 10,000 PSI
Available in Gauge, Absolute and Vacuum Pressure
330 Types)
Embedded IO-Link 1.1 protocol helps minimize
downtime and increase productivity (Display Models
Only)
320
Test certificate included in all units
316L Stainless Steel Wetted Parts
IO-Link 2 x PNP, PNP + Analog 420mA
IP67 rated enclosure
PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 4
836P Solid State Pressure
Non Display Overview
When connected to Standard IO Card, PIN 4 will operate as an ON/OFF Output. PIN 4 will
start IO-Link communications when connected to IO-Link Master
PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 8
836P Solid State Pressure
Test Certificate
Faster Time to
$
Lower Total Cost Improved Asset Enterprise Risk
Market of Ownership Utilization Management
EtherNet I/P
EtherNet I/P
IO-Link combines powerful data and diagnostics with simple implementation and configuration,
resulting in:
Reduced inventory and operating costs
Increased uptime/productivity
Simplified design, installation, setup and maintenance
Enhanced flexibility and scalability
control system
control system
Rockwell Automation is the only company with the complete IO-Link solution: PLCs, an IO-Link master and IO-Link enabled
sensors
Premier Integration: When using the full Rockwell Automation solution, customers are afforded a enhanced level of integration
plus features and functionality not available with competitive offerings. This includes:
Studio 5000 Logix Designer, a single programming environment that provides access to IO data and configuration parameters across the
entire Integrated Architecture system
Add-on-Profile (AOP) that simplifies the setup of Allen-Bradley IO-Link devices by organizing sensor information and configurable
parameters for intuitive programming
Automatic Device Configuration (ADC): Sensor configurations can be stored in the IO-Link master and Logix controller and downloaded
to new/replacement sensors (of the same catalog number) without the need for re-teaching/re-programming
Tag Names and structure for IO-Link process data are automatically generated from the sensor IO Device Description (IODD) files
Correlation of the Read-Write (RW) parameter values of connected IO-Link devices is compared to those stored in the controller so any
differences can be mitigated
One programming No incremental cost for Easy access to actionable ADC capabilities reduce
environment for Sensors sensors contextualized information mistakes in device
and Architecture No wiring changes replacement
Real-time diagnostics
Seamless integration into Scalable solution enable optimize preventative Restrict configuration
RA E/IP Architecture IO-Link functionality as maintenance and changes to authorized
Intuitive programming needed troubleshooting personnel only
simplifies initial setup Reduce device inventory Multiple Profiles facilitate Ensure BOM compliance
and helps eliminate logic 50% by streamlining SKUs flexible manufacturing
errors
IO-Link simplifies the user experience at a lower cost without a learning curve
PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.
836P Solid State Pressure
836P Display IO-Link Features
836P Display IO-Link enabled sensors can be configured in Studio 5000 Logix Designer using the 1734-4IOL
Add-on Profile (AOP). The AOP is broken into four different tabs that describe the sensors functionality and
operation:
Common Tab: Provides general product information about the sensor specifications and IO-link IODD
information
Identification Tab: Provides the sensor catalog number, series letter, general product description including
the current product firmware, and hardware revisions
Parameter Tab: Provides an easy-to-use interface for the configuration of sensor parameters
Diagnosis Tab: Provides the ability to lock/unlock sensor configuration, enable the Locator Indicator, reset the
factory settings, and more
836P Display IO-Link enabled sensors can be configured in Studio 5000 Logix Designer using the 1734-4IOL
Add-on Profile (AOP). The AOP is broken into four different tabs that describe the sensors functionality and
operation:
Common Tab: Provides general product information about the sensor specifications and IO-link IODD
information
Identification Tab: Provides the sensor catalog number, series letter, general product description including
the current product firmware, and hardware revisions
Parameter Tab: Provides an easy-to-use interface for the configuration of sensor parameters
Diagnosis Tab: Provides the ability to lock/unlock sensor configuration, enable the Locator Indicator, reset the
factory settings, and more
Process Data is any information the sensor sends back to the IO-Link master each
communication cycle, i.e. the most recent sensor status
For the 836P, Process Data consists of two parameters:
Triggered1
Triggered2 (Only for 2 x PNP models)
Pressure in PSI
Descriptive controller tags are automatically generated for all process data parameters when an
Allen-Bradley IO-Link sensor is connected to an Allen-Bradley IO-Link master
The controller tag values can be viewed from the Controller Organizer Tree as shown on the next
slide
Pressure:
Provides the pressure value in PSI measured by the unit. For sensors with pressure range
from:
2 decimal points resolution 0 99 PSI models 50 PSI will display 5000 in process data
1 decimal point resolution 0 999 PSI models 50 PSI will display 500 in process data
0 decimal point resolution 0 8000 PSI models 50 PSI will display 50 in process data
Voltage : 15 35V DC
Current Consumption : 450 mA max
Output Type : 2x PNP models, 1xPNP + 4 20 mA
Enclosure:
Housing: 304 Stainless Steel
User Interface: Polycarbonate and ABS
Keyboard: TPE-E
Wetted parts : Stainless Steel 316L
Operating Environment: IP67
Operating Temperature: -20C to 80C
Certifications: CE and cULus
Technical Collateral:
836P w/ IO-Link User Manual: Available May 10th 2016. 836P-UM001A-EN-P
1734 4IOL User Manual: 1734-UM020A-EN-E
Add On Instructions Sample Code: Available May 15th 2016. Download from Sample Code Library
Faceplates:
IODD Files: Download from Product Compatibility & Download Center
2D and 3D CAD Drawings
ProposalWorks (RAISE)
PUBLIC