Você está na página 1de 33

836P Pressure Portfolio

Solid-State Pressure Condition Sensors

May 2016

PUBLIC

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


Agenda
Target Applications
836P Pressure Sensors Overview
IO-Link Features and Benefits

Collateral and Ordering Information

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


Target Applications
Skids Balers Filter Press Machines Waste Water

CIP Machines Hydraulic Power Units Automotive Tank Level Detection

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


836P Solid State Pressure
Product Overview

Display Non- Display Pressure Sensing Range from -14.5 to 10,000 PSI
Available in Gauge, Absolute and Vacuum Pressure
330 Types)
Embedded IO-Link 1.1 protocol helps minimize
downtime and increase productivity (Display Models
Only)
320
Test certificate included in all units
316L Stainless Steel Wetted Parts
IO-Link 2 x PNP, PNP + Analog 420mA
IP67 rated enclosure
PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 4
836P Solid State Pressure
Non Display Overview

Pressure Ranges : -14.7 (-30 inHg)10,000 psi


Available in Gauge , Absolute and Vacuum pressure
measurement types
Enclosure Housing 316L SS
Wetted Parts: 316L Stainless Steel
Process Connections :
NPT (Male/Female)
G BSPP ( Male / Female)
33 mm GB
(apprx.) SAE 7/16-20 UNF Male
Electrical Outputs : 420 mA
IP67 rated enclosure

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 5


836P Solid State Pressure
Display Overview with IO-Link 1.1

Pressure Ranges : -14.58,000 psi


Available in Gauge , Absolute and Vacuum pressure measurement types
Compact Housing: 316L SS
Sensing Element : 316L SS
Process Connections :
NPT (Male/Female)
G BSPP ( Male / Female)
GB
SAE 7/16-20 UNF Male
Outputs :2 x PNP , 1 PNP + 420 mA
Easy-readable and robust display
Intuitive + Fast setup
IP67 rated enclosure

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 6


836P Solid State Pressure
Product Configuration Overview

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 7


836P Solid State Pressure
Output Configuration

836P Display Models

836P Non-Display Models

When connected to Standard IO Card, PIN 4 will operate as an ON/OFF Output. PIN 4 will
start IO-Link communications when connected to IO-Link Master
PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 8
836P Solid State Pressure
Test Certificate

All 836P sensors include individual test certificate


PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 9
836P Solid State Pressure Sensors
IO-Link Features and Benefits

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


IO-Link Features and Benefits
What is IO-Link?
IO-Link is a worldwide open-standard protocol (IEC 61131-9) that allows sensors to easily
integrate into The Connected Enterprise
IO-Link is NOT a fieldbus but an enhanced development of the current connection technology
for sensors and actuators
IO-Link combines powerful data and diagnostics with simple implementation and configuration,
resulting in:
Reduced inventory and operating costs
Increased uptime/productivity
Simplified design, installation, setup and maintenance
Enhanced flexibility and scalability

Faster Time to
$
Lower Total Cost Improved Asset Enterprise Risk
Market of Ownership Utilization Management

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 11


IO-Link Features and Benefits
How are Field Signals Handled Today

EtherNet I/P

Photo Sensor/Color Analog Measurement Sensors


Sensor (Analog Input)
(Digital Input)

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 12


IO-Link Features and Benefits
How Does it Change with IO-Link?

EtherNet I/P

Photo Sensor/Color Analog Measurement Sensors


Sensor Actuator/Valve Manifold

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 13


IO-Link Features and Benefits
Additional IO-Link Information

IO-Link combines powerful data and diagnostics with simple implementation and configuration,
resulting in:
Reduced inventory and operating costs
Increased uptime/productivity
Simplified design, installation, setup and maintenance
Enhanced flexibility and scalability

See the IO-Link video for an overview

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 14


IO-Link Features and Benefits
An Enabling Technology for the Connected Enterprise

Enabled by integrated control and information, The Connected


Connected Enterprise
Enterprise allows us to create a smarter, more productive and more
secure environment
The Connected Enterprise facilitates the convergence of information Integrated Architecture

technology and operations and the real-time information flow between


them.
A-B Controller
Based on IO-Link technology, our portfolio of smart sensors and I/O
are the foundation of integrated control and information, providing
seamless visibility of field data through your Integrated Architecture A-B IO-Link Master

control system

A-B IO-Link Sensors

42JT 42EF 45CRM 871TM

Smart Sensors. Smart Machines. Smart Manufacturing

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 15


IO-Link Features and Benefits
An Enabling Technology for the Connected Enterprise

Enabled by integrated control and information, The Connected


Connected Enterprise
Enterprise allows us to create a smarter, more productive and more
secure environment
The Connected Enterprise facilitates the convergence of information Integrated Architecture

technology and operations and the real-time information flow between


them.
A-B Controller
Based on IO-Link technology, our portfolio of smart sensors and I/O
are the foundation of integrated control and information, providing
seamless visibility of field data through your Integrated Architecture A-B IO-Link Master

control system

A-B IO-Link Sensors

42JT 42EF 45CRM 871TM

Smart Sensors. Smart Machines. Smart Manufacturing

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 16


IO-Link Features and Benefits
Benefits of the Rockwell Automation IO-Link Solution

Rockwell Automation is the only company with the complete IO-Link solution: PLCs, an IO-Link master and IO-Link enabled
sensors

Premier Integration: When using the full Rockwell Automation solution, customers are afforded a enhanced level of integration
plus features and functionality not available with competitive offerings. This includes:
Studio 5000 Logix Designer, a single programming environment that provides access to IO data and configuration parameters across the
entire Integrated Architecture system

Add-on-Profile (AOP) that simplifies the setup of Allen-Bradley IO-Link devices by organizing sensor information and configurable
parameters for intuitive programming

Automatic Device Configuration (ADC): Sensor configurations can be stored in the IO-Link master and Logix controller and downloaded
to new/replacement sensors (of the same catalog number) without the need for re-teaching/re-programming

Tag Names and structure for IO-Link process data are automatically generated from the sensor IO Device Description (IODD) files

Correlation of the Read-Write (RW) parameter values of connected IO-Link devices is compared to those stored in the controller so any
differences can be mitigated

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 17


Key Benefits of IO-Link

Faster Time to Market


$ Lower Total Cost Improved Asset Utilization Enterprise Risk Management
of Ownership

One programming No incremental cost for Easy access to actionable ADC capabilities reduce
environment for Sensors sensors contextualized information mistakes in device
and Architecture No wiring changes replacement
Real-time diagnostics
Seamless integration into Scalable solution enable optimize preventative Restrict configuration
RA E/IP Architecture IO-Link functionality as maintenance and changes to authorized
Intuitive programming needed troubleshooting personnel only
simplifies initial setup Reduce device inventory Multiple Profiles facilitate Ensure BOM compliance
and helps eliminate logic 50% by streamlining SKUs flexible manufacturing
errors

Smart Sensors. Smart Machines. Smart Manufacturing.


PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.
IO-Link Features and Benefits
How does IO-Link Compare against Other Industrial Protocols

Features IO-Link AS-i HART Foundation FieldBus Ethernet IP DeviceNet


Topology One-to-One One-to-One, Multi-drop One-to-One, Multi-drop Multi-drop One-To-One, Multi-drop Multi-drop
DOB late 2000's late 1980's early 1980's mid 1990's early 1990's early 1980's
Popular In Limited Europe Worldwide Worldwide Worldwide Worldwide North America
Comms Speed Fast Mid Slow Mid Fast Mid
Built-InAutomatic Device
Yes No No No Yes No
Configuration
Addressable No Yes Yes Yes Yes Yes
Compatibility with Installed
Yes Yes Yes No No No
Base
Required Pin-Out 3-wire 2-wire 2-wire 4-wire 5-wire
Requires Special Cabling No Yes No Yes Yes Yes
Special Power Supply
Yes Yes Yes Yes Yes Yes
Required
Heavy Process Material Handling,
Material Handling, Packaging, Material Handling and Wide adoption in
Heavy Process Industries Industries and Power Packaging
Localized Process Packaging multiple industries
Target Industries Plants Industries
Operator Competency Low High High High Med High
Implementation cost Low Med Low Med Med High
Single Catalog Number Yes No No No No No

IO-Link simplifies the user experience at a lower cost without a learning curve
PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.
836P Solid State Pressure
836P Display IO-Link Features

Triggered1: provides indication when the target is detected in the


process data
Triggered2: provides indication when the target signal is marginal and
the sensor is about to fail in the process data
Pressure: provides indication when the target signal is marginal and the
sensor is about to fail in the process data
Sensor Configuration: enables the operator to optimize the sensor
settings for the application
Uniquely identifiable serial number: helps ensure sensors are installed
in proper locations during commissioning
Lock/Unlock Pushbutton: prevents unauthorized changes of
parameters by locking the push button.

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


836P Solid State Pressure
Add-On Profile (AOP) for the 836P

836P Display IO-Link enabled sensors can be configured in Studio 5000 Logix Designer using the 1734-4IOL
Add-on Profile (AOP). The AOP is broken into four different tabs that describe the sensors functionality and
operation:

Common Tab: Provides general product information about the sensor specifications and IO-link IODD
information

Identification Tab: Provides the sensor catalog number, series letter, general product description including
the current product firmware, and hardware revisions

Parameter Tab: Provides an easy-to-use interface for the configuration of sensor parameters

Diagnosis Tab: Provides the ability to lock/unlock sensor configuration, enable the Locator Indicator, reset the
factory settings, and more

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


836P Solid State Pressure
Add-On Profile (AOP) for the 836P

836P Display IO-Link enabled sensors can be configured in Studio 5000 Logix Designer using the 1734-4IOL
Add-on Profile (AOP). The AOP is broken into four different tabs that describe the sensors functionality and
operation:

Common Tab: Provides general product information about the sensor specifications and IO-link IODD
information

Identification Tab: Provides the sensor catalog number, series letter, general product description including
the current product firmware, and hardware revisions

Parameter Tab: Provides an easy-to-use interface for the configuration of sensor parameters

Diagnosis Tab: Provides the ability to lock/unlock sensor configuration, enable the Locator Indicator, reset the
factory settings, and more

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


836P Solid State Pressure
AOP Overview for 836P

The Common tab displays


general information (read-only)
about the sensor:
Vendor
Description
Part number
IO-Link Revision

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


836P Solid State Pressure
AOP Overview for 836P

Device Information in the


Identification tab shows device
information of the sensor, user
specific information, and
revision information. These are
read-only data fields
automatically populated based
on the sensor.

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


836P Solid State Pressure
AOP Overview for 836P

The Parameter tab is where the user


can configure the behavior of the
sensor output. The IO-Link master
uses these parameters for validation
purposes.
Triggered1 and Triggered2 Set
Points
Hysteresis or Window Mode
Output Polarity (N.O. or N.C)
Output On or OFF Delay

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


836P Solid State Pressure
AOP Overview for 836P

The Diagnosis tab allows the user to


test some of the basic features of
the sensor such as:
Locking/unlocking local
sensor settings
Change Display
measuring unit
Change display rotation
and update rate
Enable or Disable
Location Indication

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


836P Solid State Pressure
Process Data and Controller Tags

Process Data is any information the sensor sends back to the IO-Link master each
communication cycle, i.e. the most recent sensor status
For the 836P, Process Data consists of two parameters:
Triggered1
Triggered2 (Only for 2 x PNP models)
Pressure in PSI

Descriptive controller tags are automatically generated for all process data parameters when an
Allen-Bradley IO-Link sensor is connected to an Allen-Bradley IO-Link master
The controller tag values can be viewed from the Controller Organizer Tree as shown on the next
slide

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


836P Solid State Pressure
Controller Tags
Triggered1:
This process bit toggles high (1) when the pressures the predetermined set point and low (0)
when the sensor reaches the predetermined reset point.

Triggered2 (Only on models with 2 x PNP outputs):


This process bit toggles high (1) when the pressures the predetermined set point and low (0)
when the sensor reaches the predetermined reset point.

Pressure:
Provides the pressure value in PSI measured by the unit. For sensors with pressure range
from:
2 decimal points resolution 0 99 PSI models 50 PSI will display 5000 in process data
1 decimal point resolution 0 999 PSI models 50 PSI will display 500 in process data
0 decimal point resolution 0 8000 PSI models 50 PSI will display 50 in process data

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


836P Solid State Pressure
Technical Specifications

Voltage : 15 35V DC
Current Consumption : 450 mA max
Output Type : 2x PNP models, 1xPNP + 4 20 mA
Enclosure:
Housing: 304 Stainless Steel
User Interface: Polycarbonate and ABS
Keyboard: TPE-E
Wetted parts : Stainless Steel 316L
Operating Environment: IP67
Operating Temperature: -20C to 80C
Certifications: CE and cULus

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


836P Solid State Pressure
Launch Materials and Supporting Collateral
Marketing Collateral:
Smart Sensors with IO-Link Brochure: IOLINK-BR001A-EN-P
IO-Link Technology Website: http://ab.rockwellautomation.com/Networks-and-Communications/IO-Link
836P Product profile: 836P-IN001A-P
Updated 836P Website Available May 15th 2016
Point I/O Master for IO-Link Product Profile: 1734-PP001E-EN-P

Technical Collateral:
836P w/ IO-Link User Manual: Available May 10th 2016. 836P-UM001A-EN-P
1734 4IOL User Manual: 1734-UM020A-EN-E
Add On Instructions Sample Code: Available May 15th 2016. Download from Sample Code Library
Faceplates:
IODD Files: Download from Product Compatibility & Download Center
2D and 3D CAD Drawings
ProposalWorks (RAISE)

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


836P Solid State Pressure
836P Display - Ordering Information

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


836P Solid State Pressure
836P Non-Display - Ordering Information

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.


Thank you!

PUBLIC

www.rockwellautomation.com

PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.

Você também pode gostar