WELCOME FOR THE PRESENTATION ON - Best Practice
ELECTRICAL EQUIPMENT INSTALATION AND SAFETY PRODUCTS
Earthing & Protection

Larsen & Toubro ECC (Solar Power Div)

Nature Resources for Generating Power


Smart India Smart Solar Power Plan 2022
Wind 60 GW
Sun + High Energy Storage Batteries(100 GW)
Sun Power and Other Source
India Plan 100GW Solar Power in Year 2022
Solar Power Now Changing Many Phases
Use with Genset
Use with Wind Power
Use with High Energy Storage(Battery)
Instalation on Ground/Cannel Mounted
Instalation on Roof (Building)
Instalation on Water (Floating)
Instaltion on Building(BIPV Building Integrated Transparent
Photovoltaic Solar Glass
Easy to generate power as our Choice
Mr.Neeraj Saini Inspiration and Head of JMV LPS Ltd
We work for
Nation and International
Products and Certification
Manufacturing, Design ,Supply and Instalation
JMV LPS Ltd Commitment to development all
Important Products Require by Nation for Best
Practice of Electrical Equipment Instalation and
Safety of Products Earthing and Protection.
Exeperience to Optomise and Economical Solar Project Cost
with out Compromise Technical and National Standard.
Strong In House Design Experience Team
Strong Experience in Solar PV Power Field
Strong Documentation for Customer and Consultants
Supervision On Site Support for Instalation
Operation and Maintenance for our Products on Site
Project Smart India /Smart Solar Power /Smart Transmission

Safe Practice in Earthing and Protection


External/Internal Surge Source
An Arcing Fault is the flow of current through
the air between phase conductors or phase
conductors and neutral or ground. Concentrated
radiant energy is released at the point of arcing
an a small amount of time resulting
in Extremely High Temperature.
Fire Accident in Solar PV Power Plant
Reason Lose Contact Earthing Disorder and Lightning
Solar Panel Fire Accident
More Picture Fire in Solar Pv Power Plant
More Picture
Fire Component Level
Solar PV Power Plant
Surge in Systems and Result
Surge in DC Application
Sikhana to Padega Hi Follow Electrical Safety
Follow Safety in Electrical Instalation Shocks
Best Earthing Practice to perform equipment well &
protects from shock (As per Latest NBC-2016)

1. Equipment Earthing
CI/GI/ Copper Plate earthing with maintenance
material
Copper/ Copper Bonded Steel Rod with
maintenance free earthing system

2. GRID Earthing
Earthing Design and Require Result
For substation Large Power below 1.00Ohm
For substation Small Power below 2.00Ohm
SCADA/TELECOM and AutomationFor substation Large
Power below 0.50Ohm
Tower and Other Structure between 8-15Ohm
Lightning Surge Protection 50KA below 5Ohm or 100KA
between 8-15Ohm
Follow Standard IEC /IEEE
Recommended use of Hybrid Metal to Protect from Theft
Copper Clad Steel/Alumineum Clad Copper
Exothermeic weld IEEE 837
Surge Protection Recommation
Surge Protection use Recommendation
We are offering
Surge Protection Devices as IS/IEC 62305-4
Lightning Surge Distance Strike
Lightning Impact
v
Products
Copper Cladded Conductor For Electrical
Installation

The Copper Clad Steel Grounding Conductor is made up of steel with the coating of 99.99% pure
copper. These conductors/ wires
or strands are equipped with the strength of steel with the conductivity and copper with the better
corrosion resistance property. The concentric copper cladding is metallurgic ally bonded to a steel
core through a continuous,
solid cladding process using pressure rolling for primary bonding. The copper cladding
thickness remains constant surrounding steel. We use different steel grades for the steel core result in
Dead Soft Annealed, High strength and Extra High Strength Characteristics.
The Copper Clad Steel Wire yields a composite conductivity of 21%, 30% and 40% IACS, and available
in Annealed and Hard drawn. We are delivering products with varied conductivity and tensile strength
as per the customer need. Further, the wire can be processed to be silver plated or tinned copper
clad steel wire.
Most Efficient Joint Process

It is efficient and superior to all existing surface to-surface


mechanical retention connectors.
What is Exothermic Welding System?
Copper to Bi-Metal and Alumenium
Types of Exothermic Joints:

Possible to join any bi metal except aluminum


Exothermic welding is a process of making maintain free highly molecular bonding process is superior in
performance connection to any known mechanical or compression-type surface-to-surface contact connector.
Exothermic weld connections provide current carrying (fusing) capacity equal to that of the conductor and will
not deteriorate with age.
It offers Electrical connections between two or more copper to copper and copper to steel conductors.
Highly portable method as it does not require any external power source or heat source, so it can be done
almost anywhere.
It provides strong permanent molecular bond among metallic conductors that cannot loosen and further will
not deteriorate with age.
Connection does not corrode with time and it offers permanent conductivity.
Copper Clad Steel Solid ROD and Conductor
India Life can be Save from Lightning
Horrifying Losses Due To Devil Lightning
LIGHTNING FORMATION
Facts about Lightning
A strike can average 100 million volts of electricity
Current of up to 200,000 amperes
Can generate 54,000 oF
10/350MicroSec/50KA Fault Current/Discharge in
Nano Sec
Protection
Earthing Design100KA Fault Current/Joints Exothermic
/Flexible Down Conductor with Shortest Route &
Less Corner
Lightning Protection Standard use in India
( IEC 62305-3 and 4)
Working Principle Angullar No Compromise with Design Max
Protection 30Mtrs from One
No Product warrenty from Manufacturer
High Maintenance Require
NFC17-102(2011) Now Europeon Standard(ESE LA)
Working Principle Radius Compromise with Design Possible
with Increasing Qty of ESE
Max Protection 109 Mtrs Radius from One
Manufacturing Warrenty and Test Certificate for Products
Available
Maintenance on Call Basis
ESE Type Lightning Protection Mendatory in Solar Project
Freedam in design and Instalation Lowest Project Cost
Standards Worldwide for Lightning NFC17-102 and IEC62305-3
Lightning Risk Assessment Study is actually the
measure of risk of a lightning strike and probability of
damages. As Per IEC62305-2.

All these calculations are based on:


Lightning strike density in that particular area(provided byOMV i.e.Ng = 8),
Danger for people,
Occupation coefficient of structure,
Relative location of site,
Fire Risk,
Associated services,
Electrical Lines,
Lightning Protection Level,
Surge Arrestor and
Dimensions of installation.
Lightning Risk Calculation as per IEC62305-2
Ligthing Risk Calculation
Lightning Risk Calculation
Lightning Risk Calculation
Risk Assessment Calculator as per IS/IEC 62305
Air- Termination System

1. Vertical Rods- simple


shaped buildings

2. Catenary wires-
suitable for all cases

3. Meshed/ Grid
Conductors- best for
where plane/ pitch
roof surfaces
Air- Termination System Design
Lightning Protection As Per NF C 17 102/UNE 211186

The ESE air terminal is a terminal which enables to generate artificially an upward leader earlier than a simple rod, with an
ionization system, in order to establish a special impact on its point. The capture of the lightning strike being faster than a
simple rod, this technology enables to benefit from larger protection areas, ensuring protection for large dimensions structures.

The generated protection radius depends on the early streamer emission value of the air terminal (t in s), its height, and the
efficiency of the protection. The protection radius ensured by this type of air terminal is 120 m (Protection level IV, height = 60
m , early streamer emission time 60s).

The NFC 17-102/UNE 211186 standard describes the installation procedure for this type of air terminal.

The installation of this type of air terminal is easy and cheaper than other technologies.

It can protect whole buildings with one E.S.E. air terminal. It enables the protection of a structure and its environment, the
protection of opened areas and well integrate in the architecture of a structure without aesthetic alteration.

1 ESE, 2 down conductors and 2 earthing systems are necessary to ensure the protection.
Early Streamer Emission Air Terminal
An active and advance technology device based on the principle of
Corona effect.

Internationally accepted technology complying standard NFC 17-102.

Active Protection not only protects the structure also protect


surroundings & open areas.

Made up of stainless steel SS-316L hence highly corrosion resistant


and long lasting.

More life due to corrosion resistant material is used.

Single installation offering maximum radius of protection of 109


meters which is very large in comparison to conventional lightning
system.

ESE air terminal is very quick in response.

Excellent, no electronic device.

Economical solution.

Easy to Install.
IEC Declaration by CENELEC for
NFC17-102
BT has confirmed that ESE National Standards would remain valid and thus BT recognized
there ould e o e ide e of o fli t et ee NF C a d IEC EN sta dards a d
consequently there is no reason, technical or otherwise, for the withdrawal of the respective
national standard.BT has requested that this standard be modified in order to cancel all
refere e to the IEC EN series, allowing the NF C sta dard to e ist, ith the
proposal of possible future migration to international level (lEC). Accordingly, it was established
that European ESE standards (France, Spain, Portugal, Slovaquia, etc.) will not
conflict with other European standards and will remain valid.
GIMELEC would draw your attention to the fact that
the ter s of refere e of NF C a d
other standards, addressing alternative terminals (NF
C , PR EN ) ere fro the
outset, er differe t. It is a fa t that NF C ,
whilst referring to ESE Technology also
comments on other standards for lightning protection
systems, particularly incorporating
faraday cage, franklin rod and catenary wire systems.
the 'camouflaging' of NF C 102 by IEC EN
and its proponents, that FRENCH STANDARD
NF C is still in full force.
ESE Installation Guidance

ESE AT with radius protection form 32 mtr to 107 mtr.

DMC Insulator .

GI/FRP Mast .

Down Conductor Copper / Copper Cadmium


Cable 70 sq. mm

Copper Bonded Ground Earthing


Thimble

Joint all phase wire/ cable with the help of


crimping tools and lugs

Step 1
Separation Sheet

Fixed the separation sheet between all wires/


cables

Gel / Silicon
Step 2
Close the filled Silicon enclosure from top and
bottom , complete installation is done.

Step 3
Features :
Provides cable with cable connections and jointing wires in switchboard / electric boxes Being a jelly it can be
easily fit into molds of any shape and size.
Helps in safeguarding electrical connections and also protects electrical connection joints from catching fire, sparking
and leakage current.
Eradicates all the possibilities of fire, electric shocks and sparks, etc. causes due to improper electrical connection
joints and safeguards structure, equipment and person.
Offers safety to your electrical joints from ageing, corrosion, moisture and also observes leakage current.
Advantages :
Nontoxic
Insulating
Highly reliable operation
Maintenance Free
Repairable
Cost Effective
High repeat value
Elasticity
Shape retention
Contact Professionals for Advise
We Protect You
Use Well Engineered Electrical Safety
Solutions With Us