Você está na página 1de 36

INPUTS

Fck 25 N/mm2
Fy 415 N/mm2
SBC 150 Kn/m2
Clear cover 50 mm
spacing (l) 3 m

COLUMN1
(S) a1 0.3 m
b1 0.3 m
P1 300 Kn
MX1 10 KNm
MY1 6 KNm

COLUMN2
(L) a2 0.4 m
b2 0.4 m
P2 400 Kn
MX2 12 KNm
MY2 10 KNm

SBC W/EQ 187.5 Kn/m2 (1.25*SBC)

Let the weight of footing (P') 70 Kn 10%*(P1+P2)

Area of footing (A) 5.14 m2 (P1+P2+P')/(SBC)

Size of footing 1.6 m x 4.3 m


(B) (L)

Dist.of C.G.of loads from CL of C1 1.72 m (P2*l)/(P1+P2)

Projection of Footing from c1 to left end 0.43 m (0.5*L-C.G FROM CENTRE

Projection of Footing from c2 to Right end 0.87 m (L-distance from CL of c1 t

The Net upward pressure (Po) 111.92 Kn/m2 (P1+P2+P')/(Area of footin

Net upward Pressure w per meter length (Po*B) 179.072 Kn/m (Po*B)

CHECK AGAINST MAXIMUM PRESSURE

Total Load P*=P1+P2 700 Kn


Total load P**=P1+P2+P' 770 Kn

1.6 m x 4.3 m

P**/A+MX/Z+MY/Z (W/EQ)

Upward Soil Pressure acting at corner A


=(770/(1.6x4.3)-22x6/(1.6x4.3)-16x6/(4.3x1.6) 98.74 kN/m2
Upward Soil Pressure acting at corner B
=(770/(1.6x4.3)-22x6/(1.6x4.3)+16x6/(4.3x1.6) 116.18 kN/m2
Upward Soil Pressure acting at corner C
=(770/(1.6x4.3)+22x6/(1.6x4.3)-16x6/(4.3x1.6) 107.66 kN/m2
Upward Soil Pressure acting at corner D
=(770/(1.6x4.3)+22x6/(1.6x4.3)+16x6/(4.3x1.6) 125.11 kN/m2

< 186SAFE HENCE OK

SHEARFORCE AND BENDING MOMENTS


1.6
m
C1 C2

4.3 m

0.43 m 3.00 m 0.87

244.2 Kn

77.01 Kn
1.25 m V2

V1
155.8 Kn

222.99 Kn

POC POC

7.02
Knm 0.077 40.2
m 0.585 Knm
16.56 m 67.77
Knm Knm
0.507
m
2.845
m
SHEAR FORCE
S.F Just to the left of c1 77.01 Kn 9Po*B*projection of footing from left e

S.F Just to the Right of c1 222.99 Kn (P1-Shearforce just to left of c1)

S.F Just to right face of c1 196.14

S.F Just to the Right of c2 155.8 Kn (Po*B*Projection of footing from right

S.F Just to the Left of c2 244.2 Kn (P2-Shearforce just to right of c2)

S.F just to left face of c2 178.40256 Kn

shear force changes sign between C1 and C2 hence the point of zero shear force lies between c1 and c2

lo be the distance from left End of the footing where shearforce is zero

lo 1.68 m (Po*B)/(P1)

(OR)

lo (from centre of column c1) 1.25 m

BENDING MOMENT

Sagging B.M at left face of C1 (M2) 7.02 Kn-m (Po*B)/2*(Projection of footing from le

Sagging B.M at centre line of C1 16.56 Kn-m (Po*B)/2*(Projection of footing from le

Sagging B.M at Right face of C2 40.2 Kn-m (Po*B)/2*(Projection of footing from Ri

Sagging B.M at centre line of C2 67.77 Kn-m (Po*B)/2*(Projection of footing from Ri

Maximum B.M will occur where shearforce is zero I,e at 1.68 m from left end of footing &

maximum B.M Value is M1 -122.3 Kn-m (-) indicates it willl be hogging in nature
123 (write B.M Value without negative sign)

Let the point of contraflexure occurs at a distance x from left end of footing

EQUATION 89.536 * X^2 - 300 * (X -

X (VALUES) X1 0.507 m (s) (From left End(corner) Near c1)


X2 2.845 m (L) (From left End(corner) Near c2)

Let the first point of contraflexure 0.077 m (X1-Projectioion of footing from left en
occurs at a distance, from centre
of c1 to its right

Let the second point of contrafl 0.585 m (L-X2-Projection of footing from left en
- exure occurs at a distance, from
of centre of c2 to its left

S.F at point of contraflexure (v1) 209.210496 Kn (P1-Po*B*X1)


S.F at point of contraflexure (v2) 209.45984 Kn (Po*B*X2-P1)

DEPTH FROM MAX BENDING MOMENT CONSIDERATION

Ru 3.45 REVISE Ru = 0.138*fck for fe 415


Ru = 0.133*fck for fe 500
Ru = 0.149*fck for fe 250

Effective depth required (d) 182.83 mm d=((Mu*10^6)/(Ru*B))^0.5

TOTAL DEPTH (D) Provided 400 mm

Clear cover 50 mm

REINFORCEMENT FOR HOGGING BENDING MOMENT M1

Dia of bar 16 mm

Area of bar 201.06 mm2 (pi/4)*^2

Effective depth provided (d) 342 mm (d=D-clearcover-dia of bar/2)

Area of steel (Ast1)H req 1569.68 mm2 (Ast1)H=(0.5*Fck)/(Fy)*(1-(1-((4.6*Mu1

Pt required 0.287 % (Pt=((Ast1)H*100)/(B*d)

Number of Bars 7.8070227793 (Ast1)H/(Area of Bar)


Number of Bars provieded 8

Spacing required 200 (B)/(No of Bars provided)


Spacing provided 180

Area of steel (Ast)H provided 1608.48 mm2 (Area of bar *Number of bars provided

(Pt1) provided 0.3 % (Ast1)H prov*100)/(B*d)

CHECK FOR DEVELOPMENT LENGTH :-

M2 + Lo Ld
Vu

Shear force Vu 314.19 kn (Factored)

Xu 40.33 mm Xu= (0.87*fy*(Ast1)H prov)/(0.36* fcK*

M1 188870396.592315 N-mm 188.88 Kn-m


(M1 = Moment capacity of tension steel which resists the applied bending moment),
Anchorage length (Lo) 192 mm (12*)(or) d

Development length (Ld) 752 mm

M2+Lo 943.17 mm > Ld(ok) checking the development


Vu

Continue the Above bars by a distance Lo 342 mm Beyond the point of contraflexu
And Remaining 5 Bars Provide throughout the length & these bars will serves as Anchorage

REINFORCEMENT FOR SAGGING BENDING MOMENT M2

B.M AT FACE OF COLUMN C1

Dia of bar 12 mm

Area of bar 113.1 mm2 (pi/4)*^2

Area of steel (Ast2)s required 85.55 mm2 (Ast2)S=(0.5*Fck)/(Fy)*(1-(1-((4.6*Mu2

Pt required 0.016 % (Pt=((Ast2)S*100)/(B*d)

Number of Bars Required 0.7564102564 (Ast2)S/(Area of Bar)


Number of Bars provieded 0

Spacing required #DIV/0! (B)/(No of Bars provided)


Spacing provided 0

Area of steel (Ast2)H provided 0 mm2 (Area of bar *Number of bars provided

(Pt2) provided 0 % (Ast2)S prov*100)/(B*d)

MINIMUM Pt req

Minimum Pt required 0.12 %

Minimum (Ast2)s required 768 mm2 (0.12*B*D)/(100)

Number of bars 6.7904509284 N=(Ast2)S/(Area of Bar)


Number of Bars provieded 7

Spacing required 228.5714285714 mm S=(B)/(No of Bars provided)


Spacing provided 205 mm

Area of steel provided (Ast1)S 882.74 mm2 (Area of bar *Number of bars provided

(Pt2) provided 0.17 % (Ast2)S prov*100)/(B*d)

CHECK FOR DEVELOPMENT LENGTH :-


M2 + Lo Ld
Vu

Shear force Vu 313.82 kn (Factored)

Xu 22.14 mm Xu= (0.87*fy*(Ast2)s provided)/(0.36*

M2 106064514.961644 N-mm 106.07 Kn-m


(M2 = Moment capacity of tension steel which resists the applied bending moment),

Anchorage length (Lo) 144 mm (12*)(or) d

Development length (Ld) 564 mm Ld=(0.87*fy*)/(4*bd)

M2+Lo 680 mm > Ld OK checking the development


Vu

Continue Above bars by a distance Lo 342mm Beyond the point of contraflexu


And Remaining 4 Bars Provide throughout the length & these bars will serves as Anchorage

REINFORCEMENT FOR SAGGING BENDING MOMENT M3

B.M AT FACE OF COLUMN C2

Dia of bar 12 mm

Area of bar 113.1 mm2 (pi/4)*^2

Area of steel (Ast3)s required 496.06 mm2 (Ast3)S=(0.5*Fck)/(Fy)*(1-(1-((4.6*Mu3

Pt required 0.091 % (Pt=((Ast3)S*100)/(B*d)

Number of Bars Required 4.3860300619 (Ast3)S/(Area of Bar)


Number of Bars provieded 0

Spacing required #DIV/0! S=(B)/(No of Bars provided)


Spacing provided 0

Area of steel (Ast3)S provided 0 mm2 (Area of bar *Number of bars provided

Pt3 provided 0 % (Ast3)S prov*100)/(B*d)

MINIMUM Pt req

Minimum Pt required 0.12 %

Minimum (Ast2)s required 768 mm2 (0.12*B*D)/(100)

Number of bars 6.7904509284 N=(Ast3)S/(Area of Bar)


Number of Bars provieded 7
Spacing required 228.5714285714 mm S=(B)/(No of Bars provided)
Spacing provided 205 mm

Area of steel provided (Ast3)S 882.74 mm2 (Area of bar *Number of bars provided

( Pt3) provided 0.17 % (Ast3)S prov*100)/(B*d)

CHECK FOR DEVELOPMENT LENGTH :-

M2 + Lo Ld
Vu

Shear force Vu 314.19 kn (Factored)

Xu 22.14 mm Xu= (0.87*fy*(Ast3)sprov)/(0.36* fcK*B

M3 106064514.961644 N-mm 106.07 Kn-m


(M3 = Moment capacity of tension steel which resists the applied bending moment),

Anchorage length (Lo) 144 mm (12*)(or) d

Development length (Ld) 564 mm

M2+Lo 679.6 mm > Ld OK checking the development


Vu

Continue Above bars by a distance Lo 342mm Beyond the point of contraflexu


And Remaining 4 Bars Provide throughout the length & these bars will serves as Anchorage

CHECK FOR ONE WAY SHEAR

CASE1) Check for one way shear in cantilever portion to Right of column C2

Critical section for one way shear at a distance d (effective depth) from face of column or from centreof column

Shear force at the critical section Vu 88.12 Kn Vu=(S.F just to right of c2-Po*B*Distanc

v 0.17 N/mm2 v=(Vu*10^3)/(B*d)

c 0.3 N/mm2 (Write c values from IS456-2000 tabl

PROVIDE NOMINAL SHEAR REINFORCEMENT

NOMINAL SHEAR REINFORCEMENT

Let us provide 4 legged stirrup of 8 mm Dia bar


Asv 201.06 mm2 (Asv=Number of legs*(pi/4)*dia of bar^2)

Sv 113.43 mm Sv=(0.87*fy*AsV)/(0.4*B)
Sv (provided) 110 mm

Provide 8 mm Dia , 4 Legged stirrup


At a spacing of 110 From face of column C2

CASE2) Check for one way shear in cantilever portion to Left of column C1

Critical section for one way shear at a distance d (effective depth) from face of column or from centre of column

Shear force at the critical section Vu -16.65 Kn (S.F Just to left of c1-Po*B*Distance fro

v -0.04 N/mm2 v=(Vu*10^3)/(B*d)

c 0.3 N/mm2 (Write c values from IS456-2000 tabl

PROVIDE NOMINAL SHEAR REINFORCEMENT

NOMINAL SHEAR REINFORCEMENT

Let us provide 6 legged stirrup of 8 mm Dia bar

Asv 301.59 mm2 (Asv=Number of legs*(pi/4)*dia of bar^2)

Sv 170.14 mm Sv=(0.87*fy*AsV)/(0.4*B)
Sv (provided) 165 mm

Provide 8 mm Dia , 6 Legged stirrup


At a spacing of 165 From face of column C2

CASE 3) Check for one way shear betweeen c1 & c2

LEFT OF COLUMN C2

Critical section for one way shear is At a distance d (Effective depth ) from face of column or centrE of column2
- (or) at a distance of point of contraflexure from centre of column2 585 mm whichever is nearer t

shear force at critical section Vu 220.714464 KN (S.F Just to left of c2-Po*B*Minimum (d

v 0.41 N/mm2 v=(Vu*10^3)/(B*d)

c 0.4588 N/mm2 (Write c values from IS456-2000 tabl


PROVIDE NOMINAL SHEAR REINFORCEMENT

NOMINAL SHEAR REINFORCEMENT

Let us provide 4 legged stirrup of 8 mm Dia bar

Asv 201.06 mm2 (Asv=Number of legs*(pi/4)*dia of bar^2)

Sv 113.43 mm Sv=(0.87*fy*AsV)/(0.4*B)
Sv (provided) 110 mm

Provide 8 mm Dia , 4 Legged stirrup


At a spacing of 110 From face of column C2

RIGHT OF COLUMN C1

Critical section for one way shear is At a distance d (Effective depth ) from face of column or centre of column1
(or) at a distance of point of contraflexure from centre of column1 77 mm whichever is nearer t

shear force at critical section Vu 313.803 KN (S.F Just to right of c1-Po*B*MIN(distan

v 0.58 N/mm2 v=(Vu*10^3)/(B*d)

c 0.4588 N/mm2 (Write c values from IS456-2000 tabl

PROVIDE SHEAR REINFORCEMENT

NOMINAL SHEAR REINFORCEMENT

Let us provide 0 legged stirrup of 0 mm Dia bar

Asv 0 mm2 (Asv=Number of legs*(pi/4)*dia of bar^2)

Sv 0 mm Sv=(0.87*fy*AsV)/(0.4*B)
Sv (provided) 0 mm

Provide 0 mm Dia , 0 Legged stirrup


At a spacing of 0 From face of column C2
TRANSVERSE REINFORCEMENT

UNDER COLUMN C1

The footing will bend transversely near each column face

Projection beyond the face 650 mm a=0.5*(B-b1)


of column (a)

width of Bending strip (bo) 984 mm bo=b1+2*d

Net upward pressure Po' 190.55 KN/m2 Po'=(p1)/(B*bo)

Considering the strip of footing 1 meter wide

Maximum bending moment will 40.26 kN-m (Po'/2)*(a)^2


occur at face of column c1, M

Mu 60.39 kN-m 1.5*M

Effective depth (d) 132.31 mm d=((Mu*10^6)/(Ru*1000))^0.5

Dia of Bar 12 mm

Area of Bar 113.1 mm2 (PI/4*DIA OF BAR^2)

Actual d 342 mm provided earlier is sufficient,Transverse reinforcement will provide


above longitudinal bars ,so available Effective depth changes to 330 mm

Area of steel (Ast) required 520.75 mm2

Pt required 0.1578030303 %

Spacing of Bars 217.18674988 mm


Spacing of Bars (provided) 210 mm

Area of steel (Ast) provided 538.5714285714 mm

(Pt) provided 0.17 %

Provide 12 mm Dia of bar At a spacing of 210 mm c/c in a Width of


CHECK FOR DEVELOPMENT LENGTH

Development length (Ld) 564 mm Ld=(0.87*fy*)/(4*bd)

Length of bar available 600 mm (a-clearcover)

SAFE

UNDER COLUMN C2

The footing will bend transversely near each column face

Projection beyond the face 600 mm a=0.5*(B-b2)


of column (a)

width of Bending strip (bo) 1084 mm bo=b2+2*d

Net upward pressure Po' 230.63 KN/m2 Po'=(p2)/(B*bo)

Considering the strip of footing 1 meter wide

Maximum bending moment will 41.52 kN-m (Po'/2)*(a)^2


occur at face of column c1, M

Mu 62.28 kN-m 1.5*M

Effective depth (d) 134.36 mm d=((Mu*10^6)/(Ru*1000))^0.5

Dia of Bar 12 mm

Area of Bar 113.1 mm2 (PI/4*DIA OF BAR^2)

Actual d 342 mm provided earlier is sufficient,Transverse reinforcement will provide


above longitudinal bars ,so available Effective depth changes to 330 mm

Area of steel (Ast) required 537.52 mm2

Pt required 0.1628848485 %

Spacing of Bars 210.410775413 mm


Spacing of Bars (provided) 200 mm

Area of steel (Ast) provided 565.5 mm

(Pt) provided 0.18 %


Provide 12 mm Dia of bar At a spacing of 200 mm c/c in a Width of

CHECK FOR DEVELOPMENT LENGTH

Development length (Ld) 564 mm

Length of bar available 600 mm

SAFE
RECTANGULAR COMBINED FOOTING

0.3 m

0.3
1.6 m
m
(B) c1

3m

0.43 m 1.72 m 1.28

m
4.3 m (L)

10%*(P1+P2)

(P1+P2+P')/(SBC)

(P2*l)/(P1+P2)

(0.5*L-C.G FROM CENTRE LINE OF C1)

(L-distance from CL of c1 to left end-C.G from centre line of c1-centre line of c2 to to C.G)

(P1+P2+P')/(Area of footing)
(A)
88.57

0.3 m

0.3
1.6 m
m
(B) c1

97.49
( C) 4.3

P*/A+MX/Z+MY/Z

Pressure acting at corner A


=(700/(1.6x4.3)-22x6/(1.6x4.3)-16x6/(4.3x1.6)
Pressure acting at corner B
=(700/(1.6x4.3)-22x6/(1.6x4.3)+16x6/(4.3x1.6)
Pressure acting at corner C
=(700/(1.6x4.3)+22x6/(1.6x4.3)-16x6/(4.3x1.6)
Pressure acting at corner D
=(700/(1.6x4.3)+22x6/(1.6x4.3)+16x6/(4.3x1.6)

< 148 SAFE


m
ection of footing from left end of c1)

rce just to left of c1)

ection of footing from right end of c2)

rce just to right of c2)

ween c1 and c2

Projection of footing from left End of c1-half of c1 distance)^2

Projection of footing from left End of c1)^2

Projection of footing from Right End of c2-half of c2 distance)^2

Projection of footing from Right End of c2)^2

m left end of footing &

lll be hogging in nature (Po*B)/2*(lo)^2-P1*(lo-Projection of footing from left end of C1)


out negative sign)

0.43 )

nd(corner) Near c1)


nd(corner) Near c2)

oion of footing from left end of c1)

ction of footing from left end of c2)


*fck for fe 415
*fck for fe 500
*fck for fe 250

^6)/(Ru*B))^0.5

over-dia of bar/2)

5*Fck)/(Fy)*(1-(1-((4.6*Mu1*10^6)/(Fck*B*d^2))^0.5)*B*d)

H*100)/(B*d)

Bars provided)

r *Number of bars provided)

v*100)/(B*d)

MAX(V1,V2)

y*(Ast1)H prov)/(0.36* fcK*b),Xu=depth of neutral axis

M1= (0.87*Fy*(Ast1)H provided*(d-0.416*Xu)


bending moment), M1>Mu1(safe)
342 mm (whichever is more)

checking the development length of bars in tension

nd the point of contraflexure, after that curtail 3 Bars


will serves as Anchorage for the stirrups..

5*Fck)/(Fy)*(1-(1-((4.6*Mu2*10^6)/(Fck*B*d^2))^0.5)*B*d)

Bars provided)

r *Number of bars provided)

v*100)/(B*d)

f Bars provided)

r *Number of bars provided)

v*100)/(B*d)
V1

y*(Ast2)s provided)/(0.36* fcK*B),Xu=depth of neutral axis

M2= (0.87*Fy*(Ast2)s provided*(d-0.416*Xu)


bending moment), M2>Mu2(safe)

342 mm (whichever is more)

checking the development length of bars in tension

nd the point of contraflexure, after that curtail 3 Bars


will serves as Anchorage for the stirrups..

5*Fck)/(Fy)*(1-(1-((4.6*Mu3*10^6)/(Fck*B*d^2))^0.5)*B*d)

of Bars provided)

r *Number of bars provided)

v*100)/(B*d)
f Bars provided)

r *Number of bars provided)

v*100)/(B*d)

V2

y*(Ast3)sprov)/(0.36* fcK*B),Xu=depth of neutral axis

M3= (0.87*Fy*(Ast3)provided*(d-0.416*Xu)
bending moment), M3>Mu3(safe)

342 mm (whichever is more)

checking the development length of bars in tension

nd the point of contraflexure, after that curtail 3 Bars


will serves as Anchorage for the stirrups..

centreof column 542 mm from centre of column c2

to right of c2-Po*B*Distance D From centre of column)

alues from IS456-2000 table 19, Pg-73,According to Pt3 provided)

SHEAR REINFORCEMENT

Vc 164160 N 164.16 Kn Vc=c*B*d)


Vs -76.04 KN (Vs=Vu-Vc)

Let us provide 0 legged 0 mm Dia bar

Asv 0 mm2 (Asv=Number of legs*(pi/4)*dia of bar^2)

Sv 0 mm Sv=(0.87*fy*Asv)/(Vs)
Sv (provided) 0 mm

Provide 0 mm Dia , 0 Legged stirrup


At a spacing of 0 From face of column C2

from centre of column 492 mm from centre of column c1

left of c1-Po*B*Distance from centre of column)

alues from IS456-2000 table 19, Pg-73,According to Pt2 provided)

or centrE of column2 542 mm


mm whichever is nearer take that as critical section

left of c2-Po*B*Minimum (distance from centre of column 2 or from point of contralexure)

alues from IS456-2000 table 19, Pg-73,According to Pt1 provided)


SHEAR REINFORCEMENT

Vc 251055.36 N 251.05536 Kn

Vs -30.3409 KN

Let us provide 0 legged 0 mm Dia bar

Asv 0 mm2 (Asv=Number of legs*(pi/4)*dia of bar^2)

Sv 0 mm Sv=(0.87*fy*Asv)/(Vs)
Sv (provided) 0 mm

The shearforce for which the stress c is -33.96 kn. This occurs at a distance
of 1.56 m (provide shear reinforcement at this length from left of column2)

Provide 0 mm Dia , 0 Legged stirrup


At a spacing of 0 From face of column C2

or centre of column1 492 mm


mm whichever is nearer take that as critical section

right of c1-Po*B*MIN(distance from centre of column1 or from distance point of contraflexure)

alues from IS456-2000 table 19, Pg-73,According to Pt1 provided)

SHEAR REINFORCEMENT

Vc 251055.36 N 251.05536 Kn

Vs 62.74764 KN

Let us provide 4 legged 8 mm Dia of bar

Asv 201.06 mm2 (Asv=Number of legs*(pi/4)*dia of bar^2)

Sv 395.66 mm Sv=(0.87*fy*Asv)/(Vs)
Sv (provided) 370 mm

The shearforce for which the stress c is 49.64 kn. This occurs at a distance
of 0.97 m (provide shear reinforcement at this length from Right of column1)

Provide 8 mm Dia , 4 Legged stirrup


At a spacing of 370 From face of column C2
^6)/(Ru*1000))^0.5

MINIMUM Pt req

Minimum Pt required 0.12 %

Minimum (Ast) required 396 mm2 (0.12*1000*d(changed)/(100)

Number of bars 3.5013263 N=(Ast)/(Area of Bar)


Number of Bars provieded 0

Spacing required #DIV/0! mm S=(B)/(No of Bars provided)


Spacing provided 0 mm

Area of steel provided (Ast) #DIV/0! mm2 (Area of bar *Number of bars provided)

(Pt) provided #DIV/0! % (Ast)prov*100)/(B*d(changed))

984 mm
^6)/(Ru*1000))^0.5

MINIMUM Pt req

Minimum Pt required 0.12 %

Minimum (Ast) required 396 mm2 (0.12*1000*d(changed)/(100)

Number of bars 3.5013263 N=(Ast)/(Area of Bar)


Number of Bars provieded 0

Spacing required #DIV/0! mm S=(B)/(No of Bars provided)


Spacing provided 0 mm

Area of steel provided (Ast) #DIV/0! mm2 (Area of bar *Number of bars provided)

(Pt) provided #DIV/0! % (Ast)prov*100)/(B*d(changed))


1084 mm from Righrt end of c2
0.4 m

0.4
m

c2

0.87 m

Mx -

My +
(B)
106.01

0.4 m

0.4
m

c2

114.93
m (L) (D)

88.57 KN/m2

106.01 KN/m2

97.49 KN/m2

114.93 KN/m2

< 148 SAFE HENCE OK


P**

CASE 1) Mx (+) My (+)


A Err:511 107.66

B Err:511 125.11

C Err:511 98.74

D Err:511 116.18

CASE 2) Mx (-) My (-)

A Err:511 116.18

B Err:511 98.74

C Err:511 125.11

D Err:511 107.66

CASE 3)
Mx (-) My (+)

A Err:511 98.74

B Err:511 116.18

C Err:511 107.66

D Err:511 125.11

CASE 4)
Mx (+) My (-)

A Err:511 125.11

B Err:511 107.66

C Err:511 116.18

D Err:511 98.74

P*

CASE 1) Mx (+) My (+)

A Err:511 97.49
B Err:511 114.93

C Err:511 88.57

D Err:511 106.01

CASE 2) Mx (-) My (-)

A Err:511 106.01

B Err:511 88.57

C Err:511 114.93

D Err:511 97.49

CASE 3)
Mx (-) My (+)

A Err:511 88.57

B Err:511 106.01

C Err:511 97.49

D Err:511 114.93

CASE 4)
Mx (+) My (-)

A Err:511 114.93

B Err:511 97.49

C Err:511 106.01

D Err:511 88.57
REINFORCEMENT FOR HOGGING BM
(TOP FACE)

Dia of BAR

1.6
m

0.849 m 1.654 m 1.797 m

4.3 m

REINFORCEMENT FOR SAGGING BM M2&M3 & TRANSVERSE REINFORCEMENT 0N LONGITUDINAL REINFORCEMENT


(BOTTOM FACE)

Dia of BAR 12 mm, spacing @ 205 mm c/c

0.984 m 1.084 m

1.6
m

0.849 m 1.654 m 1.797 m

4.3 m

Dia of BAR 12 mm, spacing @ 210 mm c/c

SIDEVIEW OF COMBINED FOOTING

NOMINAL

Dia of BAR 8 mm, spacing @ 165


6 Legged stirrup mm c/c
0.97 m NOMINAL

0.492 0.984 0.542 0.542

0.984 m 1.084
m

Dia of BAR 8 mm, spacing @ 370 Dia of BAR 8


4 Legged stirrup mm c/c 4 Legged stirrup
16 mm, spacing @ 180 mm c/c

Dia of BAR 12 mm, spacing @ 205 mm c/c

Dia of BAR 12 mm, spacing @ 200 mm c/c

Dia of BAR 8 mm, spacing @ 110


4 Legged stirrup mm c/c
mm, spacing @ 110
Legged stirrup mm c/c
REFERENCE BOOKS

TREASURE OF RCC DESSIGN -SUSHIL KUMAR

LIMIT STATE METHOD OF REINFORCED CONCRETE STRUCTURES-BC PUNMIA

Você também pode gostar