Você está na página 1de 8

Air Compressors K-6501 A/B/C

Air Dryer D-6501 A/B


Air Receivers V-6501 / 6502
MEG Heater C-5601

MEG Storage Pumps P-5601 A/B

MEG Filters N-5601 A/B

Charcoal Filter(s)

MEG Regeneration Condenser E-5601

Condensed Vapour Accumulator V-5601

MEG Storage Tank T-5601

Recovered Liquids Pumps P-5602 A/B

Gas- Gas Heat Exchanger E-5001

Low Temperature Separator V-5003

MEG Injection Pumps P-5602

Condensate Heat Exchanger E-4401

First Stage Condensate Stabilization Drum V-4401

Condensate Heater E-4402

Condensate Storage Pumps P-4401 A/B

Fuel Gas Filter N -4301


Fuel Gas Scrubber V-4302

Fuel Gas Hater E -4301


ROTARY SCREW AIR-COOLED TYPE
Heatless adsorption air dryer
vertical vessel
horizontal double barrel
heater (including re-boiler section) and still column

reciprocating pumps with electric motor drivers

vertically or horizontally
mounted cartridge type

installed in a parallel slipstream or bypass arrangement

vertical vessel

vertical pressurize tank

l operate on intermittent basis

Shell and Tube heat exchanger with a


temperature approach between 5-10
o
C

reciprocating pumps with electric motor drivers

Shell and Tube


heat exchanger with a temperature approach between 10-25
o
C.

two-phase separator

electric heater.

centrifugal pumps

vertically or
mounted cartridge type

vertical or horizontal vessel with electrical heating coil


capacity each of 1000m
each of 135 NM
with minimum retention time of 30 min

iltration efficiency shall


typically meet 99.9% removal of
particle solid with a diameter greater
than 10 microns and
99.5% liquid removal of 10 micron
and greater
ASME VIII, Division 1
API 674

ASME VIII, Division 1

API 661 6th Edition

ASME VIII, Division 1

API 620

API 610 10

ASME Boiler and Pressure Vessel Code, Section VIII Division 1


or Division 2

API 675

API 610

ASME VIII, Division 1


ASME Boiler and Pressure Vessel Code,
Section VIII Division 1