Beta Tester for IES, Inc.

Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Design Detail
Concrete f'c = 4000 psi
Rebar Fy = 60000 psi
12"
Unit Weight = 150 lb/ft

3' 0"
#6 @ 12" (S&T)
#8 @ 6"
20' 6"
21' 9"

#6 @ 12" (S&T)
#6 @ 9"
#8 @ 6" (dowels)

48"

48"
4' 0"

Heel Bars: #6 @ 6"

15"
Toe Bars: #6 @ 6"
7' 0" 4' 0" Footing S/T Bars: #4 @ 9"

12' 0"

Check Summary Criteria


Ratio Check Provided Required Combination
----- Stability Checks ----- Building Code IBC 2009
0.867 Bearing Pressure 2000 psf 1734 psf Stability Concrete Load Combs IBC 2009 (Strength)
0.076 Bearing Eccentricity 1.8" 24" Stability Masonry Load Combs ASCE 7-05 (ASD)
----- Toe Checks ----- Stability Load Comb Stability
0.608 Shear 13.23 k/ft 8.05 k/ft 1.2D + 1.6H + 1.6L Restrained Against Sliding Yes
0.763 Moment 43.47 ftk/ft 33.18 ftk/ft 1.2D + 1.6H + 1.6L Neglect Bearing At Heel Yes
0.201 Min Strain 0.0199 0.0040 1.2D + 1.6H + 1.6L Use Vert. Comp. for OT No
0.528 Min Steel 0.07 in 0.04 in 1.2D + 1.6H + 1.6L Use Vert. Comp. for Sliding No
0.229 Development 57" 13" 1.2D + 1.6H + 1.6L Use Vert. Comp. for Bearing Yes
0.500 S&T Max Spacing 9" 18" 1.2D + 1.6H + 1.6L Use Surcharge for Sliding & OT Yes
0.607 S&T Min Rho 0.0030 0.0018 1.2D + 1.6H + 1.6L Use Surcharge for Bearing Yes
----- Heel Checks ----- Neglect Soil Over Toe No
0.825 Shear 14.37 k/ft 11.86 k/ft 1.2D + 1.6H + 1.6L Neglect Backfill Wt. for Coulomb No
0.500 Moment 47.43 ftk/ft 23.72 ftk/ft 1.2D + 1.6H + 1.6L Factor Soil Weight As Dead Yes
0.183 Min Strain 0.0219 0.0040 1.2D + 1.6H + 1.6L Use Passive Force for OT Yes
0.000 Min Steel 0.07 in 0 in 1.2D + 1.6H + 1.6L Assume Pressure To Top Yes
0.128 Development 94" 12" 1.2D + 1.6H + 1.6L Extend Backfill Pressure To Key Bottom No
0.500 S&T Max Spacing 9" 18" 1.2D + 1.6H + 1.6L Use Toe Passive Pressure for Bearing No
0.607 S&T Min Rho 0.0030 0.0018 1.2D + 1.6H + 1.6L Required F.S. for OT 1.50
----- Stem Checks ----- Required F.S. for Sliding 1.50
0.409 Horz Bar Rho 0.0061 0.0025 1.2D + 1.6H + 1.6L Has Different Safety Factors for Seismic No
0.667 Horz Bar Spacing 12" 18" 1.2D + 1.6H + 1.6L Allowable Bearing Pressure 2000 psf
0.922 Moment 24.27 ftk/ft 22.39 ftk/ft 1.2D + 1.6H + 1.6L Req'd Bearing Location Middle third
1.314 Shear 10.96 k/ft 14.4 k/ft 1.2D + 1.6H + 1.6L Wall Friction Angle 25
0.539 Max Steel 0.0074 0.0040 1.2D + 1.6H + 1.6L Friction Coefficent 0.35
0.241 Min Steel 0.13 in/in 0.03 in/in 1.2D + 1.6H + 1.6L Soil Reaction Modulus 100 lb/in
0.930 Base Development 12" 11.2" 1.2D + 1.6H + 1.6L
0.771 Lap Splice Length 48" 37" 1.2D + 1.6H + 1.6L
0.000 Lap Splice Spacing 0" 6" 1.2D + 1.6H + 1.6L

QuickRWall 3.0 (iesweb.com) Page 1 of 16 Saturday 08/12/17 12:31 AM


Beta Tester for IES, Inc. Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Loads Load Combinations


DL=2 k/ft, LL=1.5 k/ft Loading Options/Assumptions
Passive pressure neglects top 0' 0" of soil.
(additional 4' 0" backfill) IBC 2009 (Strength)
1.2D
... + 1.6H + 1.6L
3' 0"

1.2D
... + 0.5L
0.9D
... + 1.6H
= 100 lb/ft 1.4D
...
1.2D
...
= 30
14' 9"

17' 6"
18' 9"

4' 0"

= 100 lb/ft
= 30
c = 0 psf

Backfill Pressure

18' 9"

18' 9"
3' 0"

732.4 lb/in
= 100 lb/ft

6' 3"
= 30 -937.5 psf
14' 9"

17' 6"
18' 9"

4' 0"

638 lb/in

5' 10"
Lateral Earth Pressure
-875 psf
At - Rest Earth Pressure Theory
Ko = 1 - sin = 1 - sin 30 = 0.50
h = Ko H = 0.50 100 lb / ft 18' 9" = 937.5 psf
Lateral Earth Pressure (stem only)
h = Ko H = 0.50 100 lb / ft 17' 6" = 875 psf

QuickRWall 3.0 (iesweb.com) Page 2 of 16 Saturday 08/12/17 12:31 AM


Beta Tester for IES, Inc. Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Passive Pressure

4' 0"

1' 4"
1200 psf 200 lb/in
4' 0"

= 100 lb/ft
= 30
c = 0 psf

Lateral Earth Pressure


Rankine Passive Earth Pressure Theory
30
Kp = tan 45 + = tan 45 + = 3.0
2 2

p = H Kp + 2 c Kp = 100 lb / ft 4' 0" 3.0 + 2 0 psf 3.0 = 1200 psf

Uniform Surcharge Pressure

(additional 4' 0" backfill)


18' 9"

18' 9"
-200 psf 312.5 lb/in

-200 psf 291.7 lb/in

Lateral Surcharge Pressure


q = Hsur = 100 lb / ft 4' 0" = 400 psf
At - Rest Earth Pressure Theory
sur = Ko q = 0.50 400 psf = 200 psf

QuickRWall 3.0 (iesweb.com) Page 3 of 16 Saturday 08/12/17 12:31 AM


Beta Tester for IES, Inc. Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Wall/Soil Weights

256.3 lb/in
583.3 lb/in

160.4 lb/in
187.5 lb/in

Bearing Pressure

e = 1.8"

5' 10.2"
564.4 lb/in

1491 psf psf


1734
1613 lb/in
Friction
F = R = 0.350 1613 lb / in = 564.4 lb / in

Bearing Pressure Calculation


Contributing Forces
Vert Force ...offset Horz Force ...offset OT Moment
Backfill Pressure -0 lb/in - 0 lb/in - -0 inlb/ft
Uniform Surcharge Pressure -133.33 lb/in 10' 0" 0 lb/in - -192000 inlb/ft
Axial Dead Load -166.67 lb/in 7' 6" 0 lb/in - -180000 inlb/ft
Axial Live Load -125 lb/in 7' 6" 0 lb/in - -135000 inlb/ft
Footing Weight -187.5 lb/in 6' 0" 0 lb/in - -162000 inlb/ft
Stem Weight -256.25 lb/in 7' 6" 0 lb/in - -276750 inlb/ft
Backfill Weight -583.33 lb/in 10' 0" 0 lb/in - -840000 inlb/ft
Soil over toe Weight -160.42 lb/in 3' 6" 0 lb/in - -80850 inlb/ft
Stem Base Shear -0 lb/in - -750.16 lb/in 1' 3" 135029 inlb/ft
Stem Base Moment 0 lb/in - 0 lb/in - 373480 inlb/ft
-1612.5 lb/in -1358090.61 inlb/ft
- 1358090.61 inlb / ft
= 5' 10.2"
- 1612.5 lb / in

QuickRWall 3.0 (iesweb.com) Page 4 of 16 Saturday 08/12/17 12:31 AM


Beta Tester for IES, Inc. Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Stability Checks

Overturning Check
Check not performed; wall has lateral support.

Sliding Check
Check not performed; restrained against sliding.

Bearing Check
Bearing pressure < allowable (1734 psf < 2000 psf) - OK
Bearing resultant eccentricity < allowable (1.8" < 24") - OK

Wall Top Displacement


Not calculated because this wall has a lateral restraint.

QuickRWall 3.0 (iesweb.com) Page 5 of 16 Saturday 08/12/17 12:31 AM


Beta Tester for IES, Inc. Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Stem Flexural Capacity


Moment
20.5

18.45

16.4

14.35

12.3

10.25 Offset (ft)

8.2

6.15

4.1

2.05

0
-60 -45 -30 -15 0 15 30
Moment (ftk/ft)

Capacity (ACI 318-08 10.2) @ 0' 0" from base [Negative bending]
As fy 0.13 in / in 60000 psi
a = = = 2.3"
0.85 f'c 0.85 4000 psi
Mn = As fy d - a / 2 = 0.90 0.13 in / in 60000 psi 9.5" - 2.3" / 2 = 59.28 ftk / ft

Capacity (ACI 318-08 10.2) @ 0' 0" from base [Positive bending]
As fy 0.05 in / in 60000 psi
a = = = 0.9"
0.85 f'c 0.85 4000 psi
Mn = As fy d - a / 2 = 0.90 0.05 in / in 60000 psi 9.6" - 0.9" / 2 = 24.27 ftk / ft

Capacity (ACI 318-08 10.2) @ 18' 1.5" from base [Negative bending]
As fy 0.08 in / in 60000 psi
a = = = 1.4"
0.85 f'c 0.85 4000 psi
Mn = As fy d - a / 2 = 0.90 0.08 in / in 60000 psi 9.5" - 1.4" / 2 = 37.55 ftk / ft

Capacity (ACI 318-08 10.2) @ 19' 0.9" from base [Positive bending]
As fy 0.05 in / in 60000 psi
a = = = 0.9"
0.85 f'c 0.85 4000 psi
Mn = As fy d - a / 2 = 0.90 0.05 in / in 60000 psi 9.6" - 0.9" / 2 = 24.27 ftk / ft

Capacity (ACI 318-08 10.2) @ 20' 6" from base [Negative bending]
As fy 0 in / in 60000 psi
a = = = 0"
0.85 f'c 0.85 4000 psi
Mn = As fy d - a / 2 = 0.90 0 in / in 60000 psi 9.5" - 0" / 2 = 0 ftk / ft

Capacity (ACI 318-08 10.2) @ 20' 6" from base [Positive bending]
As fy 0 in / in 60000 psi
a = = = 0"
0.85 f'c 0.85 4000 psi
Mn = As fy d - a / 2 = 0.90 0 in / in 60000 psi 9.6" - 0" / 2 = 0 ftk / ft

QuickRWall 3.0 (iesweb.com) Page 6 of 16 Saturday 08/12/17 12:31 AM


Beta Tester for IES, Inc. Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Stem Shear Capacity


Shear
20.5

18.45

16.4

14.35

12.3

10.25 Offset (ft)

8.2

6.15

4.1

2.05

0
-15 -10 -5 0 5 10 15
Shear (k/ft)

Shear Capacity (ACI 318-08 11.1.1, 11.2.1) @ 0' 0" from base [Positive shear]

Vc = 2 f'c d = 2 1.0 4000 psi 9.6" = 14.61 k / ft


Vn = Vc = 0.750 14.61 k / ft = 10.96 k / ft

Shear Capacity (ACI 318-08 11.1.1, 11.2.1) @ 0' 0" from base [Negative shear]

Vc = 2 f'c d = 2 1.0 4000 psi 9.6" = 14.61 k / ft


Vn = Vc = 0.750 14.61 k / ft = 10.96 k / ft

Shear Capacity (ACI 318-08 11.1.1, 11.2.1) @ 20' 6" from base [Positive shear]

Vc = 2 f'c d = 2 1.0 4000 psi 9.6" = 14.61 k / ft


Vn = Vc = 0.750 14.61 k / ft = 10.96 k / ft

Shear Capacity (ACI 318-08 11.1.1, 11.2.1) @ 20' 6" from base [Negative shear]

Vc = 2 f'c d = 2 1.0 4000 psi 9.6" = 14.61 k / ft


Vn = Vc = 0.750 14.61 k / ft = 10.96 k / ft

QuickRWall 3.0 (iesweb.com) Page 7 of 16 Saturday 08/12/17 12:31 AM


Beta Tester for IES, Inc. Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Stem Development/Lap Length Calculations


Main vertical stem bars (bottom end) - Development Length Calculation (ACI 318-08 12.2.3, 12.5)
e = 1.0 bar not epoxy - coated
= 1.0 normal weight concrete
0.02 e fy
ldh = db
f'c
0.02 1.0 60000 psi
= 1"
1.0 4000 psi
= 19"
0.7 multiplier of 12.5.3 a applies: ldh = 13.3"
8 db = 8 1" = 8.0

Main vertical stem bars (top end) - Development Length Calculation (ACI 318-08 12.2.3, 12.5)
e = 1.0 bar not epoxy - coated
s = 1.0 bars are #7 or larger
s/2 = 3" / 2 = 1.5"
cover + db / 2 = 2" + 1" / 2 = 2.5"
c = 1.5" lesser of half spacing, ctr to surface
t = 1.0 bars are not horizontal
= 1.0 normal weight concrete
Ktr = 0" no transverse reinforcement
3. fy t e s 3. 60000 psi 1.0 1.0
ld = db = 1" = 47.4"
40 c + Ktr 40 1.5" + 0"
f'c 1.0 4000 psi
db 1"

Dowels for vertical stem bars (top end) - Development Length Calculation (ACI 318-08 12.2.3, 12.5)
e = 1.0 bar not epoxy - coated
s = 1.0 bars are #7 or larger
s/2 = 6" / 2 = 3"
cover + db / 2 = 2" + 1" / 2 = 2.5"
c = 2.5" lesser of half spacing, ctr to surface
t = 1.0 bars are not horizontal
= 1.0 normal weight concrete
Ktr = 0" no transverse reinforcement
3. fy t e s 3. 60000 psi 1.0 1.0
ld = db = 1" = 28.5"
40 c + Ktr 40 2.5" + 0"
f'c 1.0 4000 psi
db 1"

2nd curtain vertical bars (bottom end) - Development Length Calculation (ACI 318-08 12.2.3, 12.5)
e = 1.0 bar not epoxy - coated
= 1.0 normal weight concrete
0.02 e fy
ldh = db
f'c
0.02 1.0 60000 psi
= 0.8"
1.0 4000 psi
= 14.2"
0.7 multiplier of 12.5.3 a applies: ldh = 10"
8 db = 8 0.8" = 6.0

QuickRWall 3.0 (iesweb.com) Page 8 of 16 Saturday 08/12/17 12:31 AM


Beta Tester for IES, Inc. Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Stem Development/Lap Length Calculations (continued)


2nd curtain vertical bars (top end) - Development Length Calculation (ACI 318-08 12.2.3, 12.5)
e = 1.0 bar not epoxy - coated
s = 0.80 bars are #6 or smaller
s/2 = 4.5" / 2 = 2.3"
cover + db / 2 = 2" + 0.8" / 2 = 2.4"
c = 2.3" lesser of half spacing, ctr to surface
t = 1.0 bars are not horizontal
= 1.0 normal weight concrete
Ktr = 0" no transverse reinforcement
c + Ktr / db = 2.3" + 0" / 0.8" = 3.0
3. fy t e s 3. 60000 psi 1.0 0.80
ld = db = 0.8" = 17.1" term 'c plus Ktr over db' limited to 2.5
40 2.5 40 2.5
f'c 1.0 4000 psi

QuickRWall 3.0 (iesweb.com) Page 9 of 16 Saturday 08/12/17 12:31 AM


Beta Tester for IES, Inc. Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Toe Checks [combination 1.2D + 1.6H + 1.6L]


Toe Unfactored Loads
Controlling Moment Unfactored Loads
Design moment Mu for toe need not exceed moment at stem base:
Mtoe = 33.18 ftk / ft < Mstem = 49.8 ftk / ft
Mu = 33.18 ftk / ft stem moment does not control
Flexure Check (ACI 318-08 10.2) 275 psf (Soil)
As fy 0.07 in / in 60000 psi 187.5 psf (Self-wt)
a = = = 1.3"
0.85 f'c 0.85 4000 psi

15"
Mn = As fy d - a / 2 #6 @ 6"
= 0.90 0.07 in / in 60000 psi 11.6" - 1.3" / 2
= 43.47 ftk / ft
1592 psf
Mn = 43.47 ftk / ft Mu = 33.18 ftk / ft
Shear Check (ACI 318-08 11.1.1, 11.2.1)
1734 psf

Vc = 2 f'c d = 2 1.0 4000 psi 11.6" = 17.65 k / ft


Toe Factored Loads
Vn = Vc = 0.750 17.65 k / ft = 13.23 k / ft
1.2D + 1.6H + 1.6L
Vn = 13.23 k / ft Vu = 8.05 k / ft
Minimum Strain Check (ACI 318-08 10.3.5)

1 = 0.850 f'c 4000 psi
As fy 0.07 in / in 60000 psi 9.29 k/ft
a = = = 1.3" 330 psf (Soil)
0.85 f'c 0.85 4000 psi
d 11.6" 225 psf (Self-wt)
t = 0.003 -1 = 0.003 -1 = 0.0199
a / 1 1.3" / 0.850

15"
#6 @ 6"
t = 0.0199 0.004
Minimum Steel Check (ACI 318-08 10.5.1)
Mn = 43.47 ftk / ft < 4 / 3 Mu = 4 / 3 33.18 ftk / ft = 44.24 ftk / ft 1963 psf 1802 psf
1963 psf 1802 psf
3 f'c 3 4000 psi
As_min = d = 11.6" = 0.04 in / in
fy 60000 psi
200 d / fy = 200 11.6" / 60000 psi = 0.04 in / in
As_min = 0.04 in / in
As = 0.07 in / in As_min = 0.04 in / in
Shrinkage Temperature Steel (ACI 318-08 7.12.2)

AST 0.4 in
ST_prov = = = 0.0030
t sST 15" 9"
0.0018 60000 0.0018 60000
ST_min = = = 0.0018
fy 60000 psi
ST_min = 0.0018
ST_prov = 0.0030 ST_min = 0.0018
18 inch limit governs
sST_max = 18"
sST = 9" sST_max = 18"
Development Check (ACI 318-08 12.12, 12.2.3)
e = 1.0 bar not epoxy - coated
s = 0.80 bars are #6 or smaller
s/2 = 6" / 2 = 3"
cover + db / 2 = 3" + 0.8" / 2 = 3.4"
c = 3" lesser of half spacing, ctr to surface
t = 1.0 12 inches or less cast below - 3.00 inches
= 1.0 normal weight concrete
Ktr = 0" no transverse reinforcement
c + Ktr / db = 3" + 0" / 0.8" = 4.0
3. fy t e s 3. 60000 psi 1.0 0.80
ld = db = 0.8" = 17.1" term 'c plus Ktr over db' limited to 2.5
40 2.5 40 2.5
f'c 1.0 4000 psi
Mu / Mn = 33.18 ftk / ft / 43.47 ftk / ft = 0.7633
Excess reinforcement reduction of 12.3.3 a applies: ld = 13"
ld_prov = 57" ld = 13"

QuickRWall 3.0 (iesweb.com) Page 10 of 16 Saturday 08/12/17 12:31 AM


Beta Tester for IES, Inc. Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Heel Checks [combination 1.2D + 1.6H + 1.6L]


Heel Unfactored Loads
Controlling Moment Unfactored Loads
Design moment Mu for heel need not exceed moment at stem base:
Mheel = 23.72 ftk / ft < Mstem = 49.8 ftk / ft
Mu = 23.72 ftk / ft stem moment does not control 400 psf (Uniform Surcharge)

Flexure Check (ACI 318-08 10.2)


1750 psf (Soil weight)
187.5 psf (Concrete self-wt)
As fy 0.07 in / in 60000 psi
a = = = 1.3"
0.85 f'c 0.85 4000 psi #6 @ 6"

15"
Mn = As fy d - a / 2
= 0.90 0.07 in / in 60000 psi 12.6" - 1.3" / 2
= 47.43 ftk / ft (neglect bearing pressure)
Mn = 47.43 ftk / ft Mu = 23.72 ftk / ft
Shear Check (ACI 318-08 11.1.1, 11.2.1)

Vc = 2 f'c d = 2 1.0 4000 psi 12.6" = 19.16 k / ft Heel Factored Loads


Vn = Vc = 0.750 19.16 k / ft = 14.37 k / ft 1.2D + 1.6H + 1.6L
Vn = 14.37 k / ft Vu = 11.86 k / ft
Minimum Strain Check (ACI 318-08 10.3.5)
640 psf (Uniform Surcharge)
1 = 0.850 f'c 4000 psi
2100 psf (Soil weight)
As fy 0.07 in / in 60000 psi
a = = = 1.3" 225 psf (Concrete self-wt)
0.85 f'c 0.85 4000 psi
d 12.6" #6 @ 6"

15"
t = 0.003 -1 = 0.003 -1 = 0.0219
a / 1 1.3" / 0.850
t = 0.0219 0.004 (neglect bearing pressure)
Minimum Steel Check (ACI 318-08 10.5.1) 11.86 k/ft
Mn = 47.43 ftk / ft 4 / 3 Mu = 4 / 3 23.72 ftk / ft = 31.63 ftk / ft
Check is waived per ACI 10.5.3
Shrinkage Temperature Steel (ACI 318-08 7.12.2)
AST 0.4 in
ST_prov = = = 0.0030
t sST 15" 9"
0.0018 60000 0.0018 60000
ST_min = = = 0.0018
fy 60000 psi
ST_min = 0.0018
ST_prov = 0.0030 ST_min = 0.0018
18 inch limit governs
sST_max = 18"
sST = 9" sST_max = 18"
Development Check (ACI 318-08 12.12, 12.2.3)
e = 1.0 bar not epoxy - coated
s = 0.80 bars are #6 or smaller
s/2 = 6" / 2 = 3"
cover + db / 2 = 2" + 0.8" / 2 = 2.4"
c = 2.4" lesser of half spacing, ctr to surface
t = 1.30 more than 12 inches cast below - 12.25 inches
= 1.0 normal weight concrete
Ktr = 0" no transverse reinforcement
c + Ktr / db = 2.4" + 0" / 0.8" = 3.1667
3. fy t e s 3. 60000 psi 1.30 0.80
ld = db = 0.8" = 22.2" term 'c plus Ktr over db' limited to 2.5
40 2.5 40 2.5
f'c 1.0 4000 psi
Mu / Mn = 23.72 ftk / ft / 47.43 ftk / ft = 0.5001
Excess reinforcement reduction of 12.3.3 a applies: ld = 11.1"
12 inch minimum controls
ld_prov = 94" ld = 12"

QuickRWall 3.0 (iesweb.com) Page 11 of 16 Saturday 08/12/17 12:31 AM


Beta Tester for IES, Inc. Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Stem Forces [combination 1.2D + 1.6H + 1.6L]


Stem Internal Forces Stem Internal Forces Stem Internal Forces
Moment Shear
20.5 20.5

3.45 k/ft
17.94 17.94

15.38 15.38

12.81 12.81

10.25 10.25

-320 psf
7.69 7.69

5.13 5.13

2.56 2.56
-1400 psf
14.4 k/ft
0 0
-50 -30 -10 10 30 -4 1 6 11 16
Moment (ftk/ft) Shear (k/ft)
-49.8 ftk/ft

Stem Joint Force Transfer


Location Force
@ stem base 14.4 k/ft

Stem Internal Forces

-320 psf

-1400 psf

QuickRWall 3.0 (iesweb.com) Page 12 of 16 Saturday 08/12/17 12:31 AM


Beta Tester for IES, Inc. Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Stem Moment Checks [combination 1.2D + 1.6H + 1.6L]


Moment
20.5

18.45

16.4

14.35

12.3

10.25 Offset (ft)

8.2

6.15

4.1

2.05

0
-60 -45 -30 -15 0 15 30
Moment (ftk/ft)

Check (ACI 318-08 Ch 10) @ 11' 4.7" from base [Positive bending]
Mn = 24.27 ftk / ft Mu = 22.39 ftk / ft
Check (ACI 318-08 Ch 10) @ 18' 1.5" from base [Positive bending]
Mn = 24.27 ftk / ft Mu = 7.85 ftk / ft
Check (ACI 318-08 Ch 10) @ 18' 2.7" from base [Positive bending]
Mn = 24.27 ftk / ft Mu = 7.85 ftk / ft
Check (ACI 318-08 Ch 10) @ 0' 0" from base [Negative bending]
Mn = 59.28 ftk / ft Mu = 49.8 ftk / ft

QuickRWall 3.0 (iesweb.com) Page 13 of 16 Saturday 08/12/17 12:31 AM


Beta Tester for IES, Inc. Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Stem Shear Checks [combination 1.2D + 1.6H + 1.6L]


Shear
20.5

18.45

16.4

14.35

12.3

10.25 Offset (ft)

8.2

6.15

4.1

2.05

0
-15 -10 -5 0 5 10 15
Shear (k/ft)

Shear Check (ACI 318-08 Ch 11.1.1) @ 0' 0" from base [Positive shear]
Vn = 10.96 k / ft < Vu = 14.4 k / ft
Shear Check (ACI 318-08 Ch 11.1.1) @ 17' 7.2" from base [Negative shear]
Vn = 10.96 k / ft Vu = 3.45 k / ft

QuickRWall 3.0 (iesweb.com) Page 14 of 16 Saturday 08/12/17 12:31 AM


Beta Tester for IES, Inc. Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Stem Miscellaneous Checks [combination 1.2D + 1.6H + 1.6L]


Minimum Steel Check (ACI 318-08 10.5.1) @ 0' 0" from base [Stem in negative flexure]
Mn = 59.28 ftk / ft < 4 / 3 Mu = 4 / 3 49.8 ftk / ft = 66.4 ftk / ft

3 f'c 3 4000 psi


As_min = d = 9.5" = 0.03 in / in
fy 60000 psi
200 d / fy = 200 9.5" / 60000 psi = 0.03 in / in
As_min = 0.03 in / in
As = 0.13 in / in As_min = 0.03 in / in
Minimum Steel Check (ACI 318-08 10.5.1) @ 4' 0" from base [Stem in negative flexure]
Mn = 54.49 ftk / ft 4 / 3 Mu = 4 / 3 5.63 ftk / ft = 7.51 ftk / ft
Check is waived per ACI 10.5.3
Minimum Steel Check (ACI 318-08 10.5.1) @ 20' 6" from base [Stem in negative flexure]
Mn = 0 ftk / ft 4 / 3 Mu = 4 / 3 0 ftk / ft = 0 ftk / ft
Check is waived per ACI 10.5.3
Maximum Steel Check (ACI 318-08 10.3.5) @ 0' 0" from base [Stem in negative flexure]
1 = 0.850 f'c 4000 psi
As fy 0.13 in / in 60000 psi
a = = = 2.3"
0.85 f'c 0.85 4000 psi
d 9.5"
t = 0.003 -1 = 0.003 -1 = 0.0074
a / 1 2.3" / 0.850
t = 0.0074 0.004
Maximum Steel Check (ACI 318-08 10.3.5) @ 4' 0" from base [Stem in negative flexure]
1 = 0.850 f'c 4000 psi
As fy 0.13 in / in 60000 psi
a = = = 2.3"
0.85 f'c 0.85 4000 psi
d 9.5"
t = 0.003 -1 = 0.003 -1 = 0.0074
a / 1 2.3" / 0.850
t = 0.0074 0.004
Maximum Steel Check (ACI 318-08 10.3.5) @ 20' 6" from base [Stem in negative flexure]
1 = 0.850 f'c 4000 psi
As fy 0.13 in / in 60000 psi
a = = = 2.3"
0.85 f'c 0.85 4000 psi
d 9.5"
t = 0.003 -1 = 0.003 -1 = 0.0074
a / 1 2.3" / 0.850
t = 0.0074 0.004
Wall Horizontal Steel (ACI 318-08 14.3.3, 14.3.5)
As_horz / shorz 0.88 in / 12"
t = = = 0.0061
t 12"
t = 0.0061 t_min
= 0.0025
3 t = 3 12" = 36"
18 inch limit governs
shorz_max = 18"
shorz = 12" shorz_max = 18"

QuickRWall 3.0 (iesweb.com) Page 15 of 16 Saturday 08/12/17 12:31 AM


Beta Tester for IES, Inc. Restrained Wall 1

123 Easy Street


AnyTown, USA 00000
(000) 000-0000

Stem Miscellaneous Checks [combination 1.2D + 1.6H + 1.6L] (continued)


Development Check (ACI 318-08 12.12, 12.2.3)
e = 1.0 bar not epoxy - coated
= 1.0 normal weight concrete
0.02 e fy
ldh = db
f'c
0.02 1.0 60000 psi
= 1"
1.0 4000 psi
= 19"
0.7 multiplier of 12.5.3 a applies: ldh = 13.3"
Mu 49.8 ftk / ft
= = 0.840
Mn 59.28 ftk / ft
Factor ldh by this ratio excess reinforcement per 12.5.3 d : ldh = 11.2"
8 db = 8 1" = 8.0
ldh_prov = 12" ldh = 11.2"
Lap Splice Checks (ACI 318-05 12.14.2.3, 12.15.1, 12.15.2) - #8 lap with #8, from 0' 0" to 4' 0" (from stem base)
1 / 5 llap = 1 / 5 37" = 7.3997 > 6.0
strans = 0" 6.0
e = 1.0 bar not epoxy - coated
s = 1.0 bars are #7 or larger
s/2 = 6" / 2 = 3"
cover + db / 2 = 2" + 1" / 2 = 2.5"
c = 2.5" lesser of half spacing, ctr to surface
t = 1.0 bars are not horizontal
= 1.0 normal weight concrete
Ktr = 0" no transverse reinforcement
3. fy t e s 3. 60000 psi 1.0 1.0
ld = db = 1" = 28.5"
40 c + Ktr 40 2.5" + 0"
f'c 1.0 4000 psi
db 1"
llap = 1.3 ld
= 1.3 28.5"
= 37" class B splice assumed
llap_prov = 48" llap
= 37"

QuickRWall 3.0 (iesweb.com) Page 16 of 16 Saturday 08/12/17 12:31 AM