RBS6201 3RD CARRIER IMPLEMENTATION

REQUIREMENTS:
1 All materials needed should be available (SUBRACK, CABLES, ADDITIONAL DUW) see Layout for Cable reference
2 Script for 3rd Carrier Configuration
3 Proper Tools (Laptop with Cables to Connect to RBS6201, 2nd Subrack Installation)
4 Softwares (Element Manger, PUTTY or HyperTerminal, Bison)

PROCEDURE
1 Open MDT call Integration to perform HC and Backup CV for Site
Call Integration to perform HC and Backup CV for Site
2 Install 2nd SUBRACK
3 Insert 2nd DUW into the expansion (still powered down)
4 Switch "ON" and Format Secondary DUW (NO CABLES CONNECTED). After Format Switch"OFF" again
5 Do the cabling as shown in the Layout
6 Run the modify script to add the 2nd DUW to the RBS (switch on 2nd DUW if you see
waiting for start up of board in the Modify-Wizzard

Note: If script loading is taking too much time (more than 10 mins) you need to switch "OFF" an
and observe if the script loading will continue

7 If already finished with script loading, check the status of the 2nd DUW with EMAS (needs to be enabled)
8 Check the status of the 2nd DUW with MOSHELL using cab
With the command cab you see that the 2nd DUW is in synch status. (Need to restart cabinet if 2nd DUW is no
9 Wait until the synch status of the 2nd DUW is StandbyReady
10 Verify with Integration Team for the Status of 2nd DUW
Create a CV (Ex. After_DUW_sync )
11 Start upgrading to R3M02
12 Export and Delete the Configuration.
13 Load the Cabinet and Site with 3rd Carrier Configuration
MPLEMENTATION

Layout for Cable reference

mat Switch"OFF" again

you need to switch "OFF" and the switch "ON" again the Secondary DUW

needs to be enabled)

art cabinet if 2nd DUW is not showing on moshell) INTEGRATION


TEAM
RPM 777 263 / 00650 - R1B
SIGNAL CABLE
(IDL to IDL Connection from
Primary to Secondary DUW)

IMPORTANT
IDL Cable labeled with
"PRIMARY" should be
connected to the primary DUW
and "SECONDARY" to
secondary DUW and do not be
mistaken to interchange,
otherwise primary DUW will be
corrupted

Connected to PDU

RPM 777 193 / 01000


R1C
DC POWER CABLE WCDMA

Need Additional 1 pc
(Power Cable for Secondary
DUW)

RPM 777 2
SIGNAL CAB
(approximat
Need additio
(Connection
RPM 777 2
SIGNAL CAB
(approximat
Need additio
(Connection

RPM 777 279 / 00650 R1B


SIGNAL CABLE
( F to F Connection from Primary
to Secondary DUW)
RPM 777 277 / 00900 R3A
SIGNAL CABLE
(approximate length 1m)
Existing from Cabinet Delivery (3pcs Only)
(Connection from RUW to Primary DUW)

CABLES NEEDED FOR 3rd CARRIER

RPM 777 277 / 00900 R3A - 3pcs

RPM 777 263 / 00650 - R1B - 1pc


RPM 777 279 / 00650 R1B - 1pc

RPM 777 193 / 01000 R1C - 1pc

RPM 777 277 / 00900 R3A


SIGNAL CABLE
(approximate length 1m)
Need additional 3 pcs for 3rd Carrier
(Connection from RUW to Secondary DUW)
RPM 777 277 / 00900 R3A
SIGNAL CABLE
(approximate length 1m)
Need additional 3 pcs for 3rd Carrier
(Connection from RUW to Secondary DUW)
R3A

very (3pcs Only)


Primary DUW)

NEEDED FOR 3rd CARRIER

7 277 / 00900 R3A - 3pcs

7 263 / 00650 - R1B - 1pc


7 279 / 00650 R1B - 1pc

7 193 / 01000 R1C - 1pc


RPM 777 263 / 00650 - R1B
SIGNAL CABLE
(IDL to IDL Connection from Primary
to Secondary DUW)

RPM 777 279 / 00650 R1B


SIGNAL CABLE
( F to F Connection from Primary
to Secondary DUW)
RPM 777 277 / 00900 R3A
SIGNAL CABLE
(approximate length 1m)
Need additional 3 pcs for 3rd Carrier
(Connection from RUW to Secondary DUW)

RPM 777 193 / 01000


R1C
DC POWER CABLE WCDMA

Need additional 1 pc
(Power Cable for Secondary DUW)
HOW TO FORMAT DUW
(Connect to RBS6201 LMT A port using Serial Connection)

username: rbs
password:rbs
Welcome to OSE Shell ose5.3.
$ reload --

OSE Delta PowerPC/BL250206


Welcome to OSE Shell ose5.3.
$ Start of @(#)CXC1725340 R3A03 2010-02-26 07:56:41 GMT
Plug-in Unit Product Name: DUW3001
Plug-in Unit Product No: KDU127161/3
Plug-in Unit Product rev: R3C
Plug-in Unit Product Date: 20110120
Plug-in Unit Product Serial: CB4G222342
Ethernet MAC_address 0: 0xC835B842FAA2
RAM size: 1024 Mbytes

Stop due to remain in basic/backup set


formathd /d
All data on volume will be destroyed. Continue? y/n (n): y

Formatting Hard Disk...


$ reload --

OSE Delta PowerPC/BL250206


Welcome to OSE Shell ose5.3.
$ Start of @(#)CXC1725340 R3A03 2010-02-26 07:56:41 GMT
Plug-in Unit Product Name: DUW3001
Plug-in Unit Product No: KDU127161/3
Plug-in Unit Product rev: R3C
Plug-in Unit Product Date: 20110120
Plug-in Unit Product Serial: CB4G222342
Ethernet MAC_address 0: 0xC835B842FAA2
RAM size: 1024 Mbytes

Stop due to remain in basic/backup set


formathd /c2
All data on volume will be destroyed. Continue? y/n (n):y

Formatting Hard Disk...


$ reload --

OSE Delta PowerPC/BL250206


Welcome to OSE Shell ose5.3.
$ Start of @(#)CXC1725340 R3A03 2010-02-26 07:56:41 GMT
Plug-in Unit Product Name: DUW3001
Plug-in Unit Product No: KDU127161/3
Plug-in Unit Product rev: R3C
Plug-in Unit Product Date: 20110120
Plug-in Unit Product Serial: CB4G222342
Ethernet MAC_address 0: 0xC835B842FAA2
RAM size: 1024 Mbytes

Stop due to remain in basic/backup set


ifconfig le0 169.254.1.1 netmask 255.255.0.0
$
1.1 Serial Connection Pin outs

2 from serial to 3 on RJ45


3 from serial to 2 on RJ45
5 from serial to 1 on RJ45

The connection between a DUW and a PC for serial connection (RS232) should look like this. Please not
RS232) should look like this. Please note that this is applicable for DUW/DUL/DUG.

use
FEMALE serial
connector
1---orange
2---green
3---red