Você está na página 1de 21
a Self-locking rod hydra ul cylinders 260 bar ERALL DIMENSIONS ~ VEGA+ a EE — 8] 14.5) 42.5}14.5| 114) wito%2 [ter oes STRAGK® Mikro-ndschltor ‘Microsimit switch NORMALIEN ‘Micro contoctour 1760-1 <-> 27601 - | a7 — > 2766/07 « Tamperaturbestindigkelt bis 90 °C, = Thermal endurance up t0.90 °C. * spitrwassergeschiat nach P66. ~ Splash prof to IP 66, * stl ber Prflechte Z 7601 ~ Adjustment via Z 760 test ight ond ond Adapter 2 7601-1. edapterZ 76011. + Réghge por Yin lmineux Z 7601 Gehiuso vorgosson und gogen KureschlB ast housing protected agoinstshor-irits joteur Z 7601 gesichert, Connection via 2 7616-1 1 Anschlufl ober Z 7616-1. Connection housing 2 7616 / 7 7617 must be + Boitior scellé ot protégé contre les courts- Belen Einscitz mobrerer Endscholter, die gleich- cused if several limit switches hove to be citeuits. ‘oilig geschaltet werden missen, ist das ‘switched simultaneously. Raccordomont vio Z 7616-1. ‘AnschluByehtiuse Z 7616 / Z 7617 erforderlich, ‘Dum plug Z 7619 must be fitted on unused Lorsque plusieurs contacteurs de fin de Nicht belegte Anschlisse misson mit Blind ‘connoctions. course doivent étre commutés en mime stacker 1 7619 dberbrckt werden, temps, utiliser impérativement le betier de soccordement 2 7616 / 1 7617. ‘Shunter les raccordements non utilisés avec dos fiches isolantes 2 7619, AcHTUNG! artenTions aeNtto Nur fiit Stewersponnung bis max. Safe only for driving voltage up to ‘Aotiliser evec une tension maxi de 48 V, 2 A. 8, 2A lg fe. 40Y,74, i 7 3| { 3) \ | @ 4 Sn = Anbeitsschaltobstond, ‘Su = Work-switching gap. ‘Sa = Vintorvlla de communication de travail S27620 © Zain Mol deaths” THERMAL PIN H STOCK SIZES AVAILABLE LENGTH “I” do ee INCH)2 13 |4 [51618 10/12y18124 —_ DIA £.005 178_|x [x [x x]x|xIx 3/16 |x |x [x [x |x |x[x [x (a, 1/4 | [xix kIx[x[x [xix I 5/16 x [x [x [x Px Ix [xX | “8 PX III XX |K—"" DIA +.020-—>| 172 x [x [x[x |x [x]x 5/8 xX IxIx [x ]x[x (SPECIAL SIZES ALSO AVAILABLE) INSTALLATION SEVERAL MEANS OF INSTALLATION ARE AVAILABLE TO MATCH THE THERMAL PIN HEAT CONDUCTORS APPLICATIONS. IN GENERAL, FACTORY INSTALLATION IS LESS EXPENSIVE AND MORE RELIABLE, BUT SATISFACTORY RESULTS CAN BE OBTAINED IN THE FIELD WITH ONE OF THE INSTALLATION KITS. THERE ARE THREE KITS AVAILABLE WITH DETAILED INSTRUCTIONS AND EVERYTHING NECESSARY TO ACHIEVE A SAFE, SIMPLE, AND EFFECTIVE INSTALLATION. 1. KOOL FLOW JOINT KIT. IN GENERAL, THIS METHOD OF FIELD INSTALLATION IS THE MOST EFFICIENT. A HOLE IN THE MOLD’S PART IS PREPARED .005 TO .016” OVERSIZE TO ACCEPT THE PIN. THE PART IS THEN HEATED IN A HOT OIL TO 300°F, AND THE KIT’S MATERIALS ARE USED TO FORM A SOLID THERMAL JOINT BETWEEN THE PART AND THE PIN. THE HOLE MUST BE CLEAN, BUT THE FINISH AND SIZE ARE NOT IMPORTANT SINCE THE JOINT METAL FILLS ALL VOIDS AND IS MORE CONDUCTIVE THAN STEEL. THE PIN CAN ONLY BE REMOVED BY DRILLING. THERMAL DIVISION NOREN PRODUCTS, INC. (415) 365-0632 3513 HAVEN AVE. MENLO PARK, CA. 94025 6.03-2 TITLE: — m———— Evectom BiaDe & Hotem joe Sur [ Te Sur — 1 STROKE+ > Neve: ' |. Foe Mare See Srp AI.OI-AL.o4. ne pundit into We slot 1 teadad pin M2.S made trom 4 cof a manifold respectively be knocked in stainless sige! i wih aplastic hamme. 2 ceramicivoiator © texibleheatediengtn ‘ 3 tuberuaieralmads tomstaiiess —@_Wubelength ere steel mariana, 14587 Pochanter measurements hotflex — technical data options: @ 2800r82mm © connection option fat plug 83 15 (w x1) standar exp. focradius P30 rom = 0.98 © cornection option: for endive R 125.0 = 0.89 rimped on clas sik nsuiats for rads R15 rm = 0.964 ‘wth protection sleeve for rediue > R tS mm = 1.00, @ connection onion: @ connection oat ads ith Ma freaded puis wits satel ruts ceramic ads (wes) andwasteremadelom ——@ wana: sutae adn centring Sianiess see! ceusdup ws toiwent © unnsated zones (0): 30 and 30.mm {depending on heated lengtn) @ 09 materia © wattage tolerance emsier = 10%. fainlace ste! (material no. 1.4541) on request © votage: up to © curent max. 25 order detals: o tube longi (a) {engin ef unneated zones (): caters voltage connections: © cxirertseshage ee Saenn Meee © satin resitance (cle) EE hon a £00 Se © sheath tomperatre max 700°C. © ciameter ioierance: 201. S8IPIS PRISE + ton Kua TITLE: | Hes Connection Fee Ware Lines In SLiDe Nore: \. Hose Firmas Te Be Next Pee Size LAR@mR Thaw Waree Line: 2 Inewe Dia Or Hose To Be Arrroximatery Same Dia As Ware Line. 3. Speciry Tee OF Hose 4 Firtines With Sources Or Beane Names. BuBerer Coouna Por thaw INSERTS Yoo Nh ~Siwver Sone” Ik "iy’ 4"Our"Warer Lines TS Be Next Pipe Size Smauere THAN Buseiee Line. 2. For Mari See Srp ALOrAl.o4. | TITLE: Busse Cocina for Uiah Sus InseeT a 4 inswers Te Be Pagkemizep Were Warem TRANSFER Occurs, 5..For Mant See Srp ALOI-ALOd. ur? Waree Lies To Be Nexr Pre Size SmaALise Tian BoBsler LING. Ring Groove DIMENSIONS Saez Srp BLO.01. 3. For’O' RING INSTALLATION On Spur Linee See Srp B2LO!. ~ Coouine For Roun INseeTs: O"2iN& Groove Dims See Srp B20.O1. , For "O'RING INSTALLATION On INSERT SPLIT LINES See Sto BLO! For "Rike INSTALLATION Ou Kounp Inseers See Stp B22.01. . Then Gzeoves & App Bacciss Wuere Zeqn. Foe Mare See Srp ALOI-ALOm. 1 2 3 4 Parse 4 INseers Te Be Parteizen Where Ware Teanerer Occurs. 5, o Bareiep Coound Foe Laeae Coes Pin WITH SLEEVE | TITLE \ io Din Warere Line - Min DIAtE SeuiT Le (Nora *3) Nore: » z 3 A a % & t App Pure Te Back Or Fy Box Pom “IN" 4 "Our" WaTee LINES. "Wu" 4 "Our" Ware LINES To Be Next Pipe Size Smacnem Than BArELeD LING. Use Seracare Barres IN Come + Bac Plare Thar Bur TeaetHe Ar Puave Spuir Line. De Nor Sovmez Om Beaze Plare Barre Te Are Ping, For"O" Rua GReove DIMENSIONS Ses Stm B20.0! Foe 'O" Ein NETALLATION ON Spur UNS See Srm BZLOl For Mart Ses Gre ALOI-Al.Od. i soa Iieaer Borr.= IngeeT Spur Line (Nore =0) Insmer Barrie Reve: L. Ose Seraeare Barrics In Inseer é Sus Insert Thar Bur TéqeTHee Ar INemer SeuT Linc. 1. De Not Soumer Oe Beaze InoeeT Baer. To Pire Puna.” 3. "IY &' Our" WaTee LINES. To Be Next Pire Size Smavume THan BAFFLED LINE. 4° For ’0" Rng Geoove Dmensions See Srp B20.01. SD For "0" Rina INSTALLATION ON SPLIT LINES See StTD'32I.01; 6. inserts TS Be PARKERIZED Were Watee Teanewem Occurs. 7. [Foz Man. See St Al OI-A1L.O4. |. Baeeien Line Cootine, Foe Hiat INSETS Newer: ;_ Do Nor Sowper Oz Baaze Barrie To Fire Pius. 2 IN’ £"Our" WaTeR LINES TS Be Next Pips Size SMALLem THAN Bareiep Linc. 3 For Mart See Al.Ol-Alod. Asspaue Puner Leary Pus Ye Besprue lenariy Pius (VEAPPK (31% Min) CetarPus*By Minus Ye ~ OPERATIONAL SEQUENCE — WBA ~ Brean Gate BP2 - STRIP SPRUE R&S- Moin OPEN Beanes pusren Low Asay Hore: |. [Use DME JirFy Laren Low. “ 2. [Use Bewevirs Spenas ON RMI. 3.{Ser 4 Dower Pea DME ~~ 4. Foe Mari SER Srp Al.OI-ALO4, ~ THREE PLATE MOLD BASE ky & ku & Q S&S o& my I S$ 4 §€ F FF § of fopSae , & & ESE &s sess #§ ¥§ LOE SLI IS Ss S$ MOLD IN OPEN POSITION SUB SPRUE SPRIPPER BUSHING SPRUE BUSHING PRIMARY STRIPPER BUSH. PRIMARY SUCKER PIN IMOLD IN CLOSED POSITION FOR MATERIALS SEE SECTION 7.01 Hy got 1 i i || —{ |! Crate Late) i c = PLS IP 1 V L. S Nf 2 S 4 1 roN i SECONDARY SPRUE | 7 SPRING | T rf i, P.LA J Zi Lis V C f a Vea B 1 N PIECE PART THREE PLATE MOLD (OPEN) TE STRIPPER Cae DEEN PLATE J 4 Z | ir | P.L2 a7 a i i Nb PIN 301-3" ° Tc THREE PLATE MOLD (CLOSED) f—— PRIMARY SPRUE CLAMP PLATE P.L.3 u DH Cc | P +! cry ff i o¢ Ii pe SPRING eel ee | L BACK UP PLATE PLA & IEF Za A dA 1 CAVITY B PLATE 7 zl cis YL i yr P.L2 u aL uv on St py i erated |GUIDE PIN Lo 301-2 RUNNER COLD SLUG & VENT A—ao, a —_ tT — >| | — DIA. PL RUNNER DIA | - CAVITY | yo | SECTION AA , || 1-1/2X in RUNNER DIA. ym T Sie "X thd \- OPEN To AIR A= eee DP & RUNNER DIA. WIDE MATERIAL exe PP, NYLON, ACETAL ,0005/.0010 ABS, PE, SAN, VINYL | _.0005/.0015 HIPS .0005/.0020 ACRYLIC, PC. .0005/.0025 503-2 | EJECTOR PIN SUB GATE || EJECTOR PIN GATE .04 MIN. 3 .04 OPEN AS NEEDED .050 DIA. fA, + DRAFT OY 2 —.188 DIA. EJECTOR PIN 5.02-5 4 X=.031 YA” PE, HIPS, PP 4 =.036 YA ACETAL, PC 4 =.046 YA PVC BASED ON .06 WALL SUBMARINE GATE GATE DIAMETER AT CUTTER POINT “X” 09 = MIN. UNDERCUT TO PULL.| GATE 4 =.041 YA NYLON, CAB, ABS “A” — PROJECTED AREA OF PART 25 - 38 ———=| EJECTOR PIN 7A 502-4 ATZETION CRM IS*D APEROR, 1D TDO'O Meena y 27 G2) a i To. vex mum heat loss, facilitating true “Open Pipeline” HOT TIP molding, ‘A two-zone “Closed Loop” Tem- perature Controller is used, one for the centre sprue heater and another for the 4 nozzle casts. *NOTE: tis recommendedthat this mold HOT TIP GATING ATG-050-10 4/62

Você também pode gostar