DriveIT Low and High Voltage NEMA Motors

Made in ABB
ABBs NEMA motor is engineered to the toughest demands of today's process industries. These
motors use the best materials and construction methods to achieve the highest quality and
reliability, and a possible operating life of over 30 years.

ABB (www.abb.com) is a leader in power and automation technologies that enable utility
and industry customers to improve performance while lowering environmental impact.
The ABB Group of companies operates in around 100 countries and employs about
105,000 people.
DriveIT NEMA Low and High Voltage Motors
Sizes 444 to 688, from 75 to 700 HP

Contents Page

1
Low voltage NEMA motors 5
1

2
2 High voltage NEMA motors 21

ABB reserves the right to change the


design, technical specification and
dimensions without prior notice.

ABB /Cat. BU/NEMA GB 10-2004 3


1

4 ABB /Cat. BU/NEMA GB 10-2004


DriveIT Low Voltage NEMA Motors

Totally enclosed squirrel cage three phase low


voltage motors,
Sizes 444 - 587, 75 to 700 HP

Mechanical design............................ 6
Rating plates.......................................6
Ordering information........................ 7
Technical data.................................... 8
Variant codes....................................13
Dimension drawings.......................15
Cast iron motors in brief................19

ABB /Cat. BU/NEMA GB 10-2004 5


Mechanical design
Range Voltage ranges for extra versatility
NEMA motors are available from 75 to 700 horsepower, A wide range of voltages up to max. 690 V for 50 Hz and
IEC motors from 0.3 to 950 horsepower (0.18 to 710 kW). 60 Hz available.

Enclosure Electrical protection


Motors are available in IP 55 totally enclosed fan cooled Thermistors (PTC) are fitted as a standard or an option,
enclosure. Totally enclosed motors are suitable for use in and thermostats are offered as option to the windings of
humid environments or dusty, contaminated atmospheres. motors to protect against overheating.

Efficiency Windings
The efficiency of a motor is the ratio of it's useful power The insulation meets class F requirements, with tempera-
output to it's total power input and is usually expressed in ture rise limited to class B (80K) in standard motors. The
percentage. ABB offers standard and energy efficient winding is a random winding of round copper wire. The wire
(high efficiency) ratings. is of at least class H insulation.

1 Bearings
All motors are provided with single-row deep groove ball
Service factor
All NEMA motors have 1.15 S.F. when the voltage and
bearings as standard and they are designed for long frequency are at the rated values as stamped on the name
lifetime. The bearing sizes appear on the name plates. plate. This means that the motor can be overloaded 15%
Roller bearings available on request. without damaging the motor.

Strong corrosion protection Optional designs


The motors are made to withstand harsh environments, We can also supply
with strong and effective protection against corrosion. The Metric motors according to IEC standards up to 710 kW
blue finish coat corresponds to ANSI 4 and Munsell 8B Metric motors in sizes 71-132 but electrically according
4.5/3.25. to NEMA standards and with UL approval

Rating plate

Rating plate, LV motor Rating plate, LV motor, Inverter duty

6 ABB /Cat. BU/NEMA GB 10-2004


Ordering information
When ordering, please include the motor type, product the motor is composed in various ways, in accordance
code, description of motor, quantity. The product code of with the following examples.

How to read the product codes

NEMA Motors 444T - 587


A B C
M2BA 445SB 3GBA 811 120 - L D A
1-4 5-6 7 8-10 11 12 13 14

Positions 1-4 Position 12 - Mounting arrangement


3GBA = TEFC three phase motor, cast iron frame A = Foot mounted, F0/Top seen from DE
L = Foot mounted, F1/LHS seen from DE
Positions 5-6
NEMA frame series
84 = 44_T
R = Foot mounted, F2/RHS seen from DE
C = C face
1
90 = 50_ B = D flange
98 = 58_ Positions 13 - Voltage/frequency code
Position 7 - Speed (pole pairs) D = 460 V 60 Hz
1 = 2 poles E = 575 V 60 Hz
2 = 4 poles Generation code - A
3 = 6 poles
4 = 8 poles Modification codes
The product code will be followed by modification codes
Positions 8-10 - Serial number when needed.
Position 11 - Dash

ABB /Cat. BU/NEMA GB 10-2004 7


NEMA LV Motors
Cast Iron, Three Phase, TEFC

Current Torque Moment Sound


Speed Eff. P.F. Approx. F.L.A Rated of Approx. pressure
2) 2)
Output Speed Frame Motor type Product code F.L. F.L. F.L. 460 575 LRA T BDT LRT inertia Weight LP
HP r/min size r/min % cos volts 2)
volts 3)
%FL A lb-ft %FL %FL lb-ft2 lbs dB(A)

75 900 444T M2BA 444 SC 3GBA 844 130-A 890 93.0 0.82 93 74.4 760 443 340 190 59 1460 68
100 1200 444T M2BA 444 SC 3GBA 843 130-A 1188 94.1 0.85 118 94 670 442 250 220 59 1460 70
100 900 445T M2BA 445MD 3GBA 844 340-A 889 93.0 0.83 121 97 750 591 330 190 71 1570 68
125 3600 444TS M2BA 444 SB 3GBA 841 120-A 3575 94.5 0.88 141 113 710 184 320 200 21.5 1390 83
125 1800 444T M2BA 444 SB 3GBA 842 120-A 1783 94.5 0.87 143 114 740 368 280 250 36 1390 72
125 1200 445T M2BA 445 MD 3GBA 843 340-A 1189 94.1 0.84 147 118 740 552 270 260 71 1570 70
125 900 505T M2BA 505 MC 3GBA 904 330-A 890 93.6 0.81 153 122 730 738 260 160 97 2010 68
125 900 447/9T M2BA 449 KHB 3GBA 844 720-A 890 93.6 0.81 153 122 730 738 260 160 97 2120 68
150 3600 445TS M2BA 445 MC 3GBA 841 330-A 3577 94.5 0.89 167 134 780 220 320 220 27 1520 83
150 1800 445T M2BA 445 MC 3GBA 842 330-A 1781 95.0 0.88 169 135 700 442 270 240 44 1520 72

1 150
150
150
150
1200
1200
900
900
505T
447/9T
447/9T
506T
M2BA
M2BA
M2BA
M2BA
505 MC
449 KHB
449 KHC
506 LA
3GBA
3GBA
3GBA
3GBA
903 330-A
843 720-A
844 730-A
904 510-A
1190
1190
890
890
95.0
95.0
93.6
93.6
0.84
0.84
0.83
0.83
176
176
181
181
141
141
145
145
740
740
720
720
662
662
886
886
260
260
260
260
220
220
170
170
97
97
128
128
2010
2120
2380
2320
75
75
76
76
200 3600 505TS M2BA 505 MB 3GBA 901 320-A 3580 95.0 0.87 229 183 750 293 290 210 33 2030 85
200 3600 447/9TS M2BA 449 KHA 3GBA 841 710-A 3580 95.0 0.87 229 183 750 293 290 210 33 2140 85
200 1800 505T M2BA 505 MB 3GBA 902 320-A 1788 95.0 0.86 230 184 740 588 270 220 62 2040 75
200 1800 447/9T M2BA 449 KHA 3GBA 842 710-A 1788 95.0 0.86 230 184 740 588 270 220 62 2180 75
200 1200 506T M2BA 506 LA 3GBA 903 510-A 1190 95.0 0.84 236 189 720 882 270 230 128 2320 72
200 1200 447/9T M2BA 449 KHC 3GBA 843 730-A 1190 95.0 0.84 236 189 720 882 270 230 128 2380 72
200 900 447/9T M2BA 449 KHD 3GBA 844 740-A 890 94.1 0.82 243 194 800 1180 280 190 162 2670 76
200 900 585 M2BA 585 S 3GBA 984 100-A 892 94.1 0.80 248 200 600 1178 230 150 247 3420 79
250 3600 447/9TS M2BA 449 KHB 3GBA 841 720-A 3580 95.4 0.89 276 221 790 367 290 220 40 2310 85
250 3600 505TS M2BA 505 MC 3GBA 901 330-A 3580 95.4 0.89 276 221 790 367 290 220 40 2230 85
250 1800 447/9T M2BA 449 KHB 3GBA 842 720-A 1787 95.4 0.86 287 230 760 735 280 220 69 2270 75
250 1800 505 T M2BA 505 MC 3GBA 902 330-A 1787 95.4 0.86 287 230 760 735 280 220 69 2140 75
250 1200 447/9T M2BA 449 KHD 3GBA 843 740-A 1189 95.0 0.84 296 237 680 1104 260 240 154 2580 72
250 1200 585 M2BA 585 S 3GBA 983 100-A 1192 95.0 0.85 290 235 680 1102 250 160 247 3420 79
250 900 586 M2BA 586 MA 3GBA 984 310-A 892 94.5 0.80 310 248 620 1473 230 150 297 3970 79
300 3600 447/9TS M2BA 449 KHC 3GBA 841 730-A 3580 95.4 0.89 330 264 790 440 290 230 50 2540 85
300 3600 506TS M2BA 506 LA 3GBA 901 510-A 3580 95.4 0.89 330 264 790 440 290 230 50 2580 85
300 1800 447/9T M2BA 449 KHC 3GBA 842 730-A 1786 95.4 0.86 344 275 790 883 290 240 83 2490 75
300 1800 506T M2BA 506 LA 3GBA 902 510-A 1786 95.4 0.86 344 275 790 883 290 240 83 2380 75
300 1200 447/9T M2BA 449 KHE 3GBA 843 750-A 1189 95.0 0.84 350 280 740 1325 260 250 183 2840 72
300 1200 586 M2BA 586 MA 3GBA 983 310-A 1193 95.4 0.85 345 280 750 1322 270 190 297 3970 79
300 900 587 M2BA 587 LA 3GBA 984 510-A 893 94.5 0.76 390 320 670 1766 270 170 346 4630 79
350 3600 447/9TS M2BA 449 KHD 3GBA 841 740-A 3578 95.4 0.90 380 304 710 514 290 190 56 2670 85
350 1800 447/9T M2BA 449 KHD 3GBA 842 740-A 1786 95.4 0.86 400 320 750 1029 280 220 95 2620 85
400 3600 585 M2BA 585 S 3GBA 981 100-A 3582 95.4 0.92 430 430 670 587 290 120 90 3420 87
400 3600 447/9TS M2BA 449 KHE 3GBA 841 750-A 3578 95.4 0.89 435 348 870 588 320 280 62 2820 85
400 1800 585 M2BA 585 S 3GBA 982 100-A 1787 95.4 0.86 455 365 680 1176 250 200 154 3420 85
400 1800 447/9T M2BA 449 KHE 3GBA 842 750-A 1786 95.4 0.86 455 364 770 1176 280 220 105 2780 85
400 1200 586 M2BA 586 MB 3GBA 983 320-A 1191 95.4 0.84 470 375 750 1765 270 200 297 3970 79
400 900 587 M2BA 587 LC 3GBA 984 530-A 893 94.5 0.82 480 380 650 2354 280 120 375 4630 79
500 3600 586 M2BA 586 MA 3GBA 981 310-A 3576 95.4 0.92 530 430 730 735 310 110 114 3860 87
500 1800 586 M2BA 586 MA 3GBA 982 310-A 1788 95.8 0.87 560 445 750 1470 260 220 195 3970 85
500 1200 587 M2BA 587 LA 3GBA 983 510-A 1191 95.4 0.84 585 475 720 2206 280 180 346 4630 79
550 1200 587 M2BA 587 LC 3GBA 983 530-A 1191 95.4 0.85 635 505 760 2427 290 130 375 4630 82
600 3600 587 M2BA 587 LA 3GBA 981 510-A 3583 95.8 0.92 635 505 790 880 360 160 142 4740 87
600 1800 587 M2BA 587 LA 3GBA 982 510-A 1790 95.8 0.87 670 540 720 1762 280 160 237 4630 85
650 3600 587 M2BA 587 LC 3GBA 981 530-A 3580 95.8 0.92 690 550 810 954 330 120 142 4740 87
650 1800 587 M2BA 587 LB 3GBA 982 520-A 1788 96.2 0.88 715 575 790 1911 300 140 237 4630 85
700 1800 587 M2BA 587 LC 3GBA 982 530-A 1792 96.2 0.89 760 605 850 2053 310 130 249 4630 87
1)
The bullet indicates a 3-letter supplement for choice of mounting arrangement, Delta connection
2)
voltage and frequency, and generation code, see ordering information page. Data at 460 V 60 Hz
3)
Data at 575 V 60 Hz
NEMA nominal efficiency according to IEEE 112.
EPAct is applicable on motors up to 200 HP.

8 ABB /Cat. BU/NEMA GB 10-2004


NEMA LV Motors, Inverter Duty Variable Torque
Cast Iron, Three phase, TEFC
For IGBT Power, Switching frequency 3 kHZ (average)
460 V, IP 55, S.F. 1.0 on VFD, 40C ambient
1)
Efficiency FL Current 1)
460 V 575 V
Output Speed Frame Motor Product FL IN IN Weight
HP r/min size type code % A A lbs
100 3600 405TS M2BN 405 MB 3GBN 801 320- 93.6 109 83 1025
100 1800 405T M2BN 405 MB 3GBN 802 320- 94.5 116 93 1025
100 1200 444T M2BN 444 SC 3GBN 843 130- 94.1 118 95 1460
100 900 445T M2BN 445MD 3GBN 844 340- 93.0 121 97 1570
125 3600 444TS M2BN 444 SB 3GBN 841 120- 94.5 141 113 1390
125 1800 444T M2BN 444 SB 3GBN 842 120- 94.5 143 115 1390
125 1200 445T M2BN 445 MD 3GBN 843 340- 94.1 147 118 1570
125 900 447/9T M2BN 449 KHB 3GBN 844 720- 93.6 153 123 2120
125 900 505T M2BN 505 MB 3GBN 904 320- 93.6 153 123 2010
150 3600 445TS M2BN 445 MC 3GBN 841 330- 94.5 167 134 1520
150
150
150
150
1800
1200
1200
900
445T
447/9T
505T
447/9T
M2BN
M2BN
M2BN
M2BN
445
449
505
449
MC
KHB
MB
KHC
3GBN
3GBN
3GBN
3GBN
842
843
903
844
330-
720-
320-
730-
95.0
95.0
95.0
93.6
169
176
176
181
136
141
141
145
1520
2120
2010
2380
1
150 900 506T M2BN 506 LA 3GBN 904 510- 93.6 181 145 2320
200 3600 447/9TS M2BN 449 KHA 3GBN 841 710- 95.0 229 184 2140
200 3600 505TS M2BN 505 MB 3GBN 901 320- 95.0 229 184 2030
200 1800 447/9T M2BN 449 KHA 3GBN 842 710- 95.0 230 184 2180
200 1800 505T M2BN 505 MB 3GBN 902 320- 95.0 230 184 2040
200 1200 447/9T M2BN 449 KHC 3GBN 843 730- 95.0 236 189 2380
200 1200 506T M2BN 506 LA 3GBN 903 510- 95.0 236 189 2320
200 900 447/9T M2BN 449 KHD 3GBN 844 740- 94.1 243 195 2670
200 900 586 M2BN 585 S 3GBN 984 100- 94.1 248 199 3420
250 3600 447/9TS M2BN 449 KHB 3GBN 841 720- 95.4 276 221 2310
250 3600 505TS M2BN 505 MC 3GBN 901 330- 95.4 276 221 2230
250 1800 447/9T M2BN 449 KHB 3GBN 842 720- 95.4 287 230 2270
250 1800 505T M2BN 505 MC 3GBN 902 330- 95.4 287 230 2140
250 1200 447/9T M2BN 449 KHD 3GBN 843 740- 95.4 296 237 2580
250 1200 585 M2BN 585 S 3GBN 983 100- 95.0 290 232 3420
250 900 586 M2BN 586 MA 3GBN 984 310- 94.5 310 248 3970
300 3600 447/9TS M2BN 449 KHC 3GBN 841 730- 95.4 330 264 2540
300 3600 506TS M2BN 506 LA 3GBN 901 510- 95.4 330 264 2580
300 1800 447/9T M2BN 449 KHC 3GBN 842 730- 95.8 344 276 2490
300 1800 506T M2BN 506 LA 3GBN 902 510- 95.8 344 276 2380
300 1200 447/9T M2BN 449 KHE 3GBN 843 750- 95.4 350 280 2840
300 1200 586 M2BN 586 MA 3GBN 983 310- 95.4 345 276 3970
300 900 587 M2BN 587 LA 3GBN 984 510- 94.5 390 312 4630
350 3600 447/9TS M2BN 449 KHD 3GBN 841 740- 95.8 380 304 2670
350 1800 447/9T M2BN 449 KHD 3GBN 842 740- 95.4 400 320 2620
400 3600 447/9TS M2BN 449 KHE 3GBN 841 750- 95.8 432 346 2820
400 3600 585 M2BN 585 S 3GBN 981 100- 95.4 430 344 3420
400 1800 447/9T M2BN 449 KHE 3GBN 842 750- 95.8 455 364 2780
400 1800 585 M2BN 585 S 3GBN 982 100- 95.4 455 364 3420
400 1200 586 M2BN 586 MB 3GBN 983 320- 95.4 470 376 3970
400 900 587 M2BN 587 LC 3GBN 984 530- 94.5 480 384 4630
500 3600 586 M2BN 586 MA 3GBN 981 310- 95.4 530 424 3860
500 1800 586 M2BN 586 MA 3GBN 982 310- 95.8 560 448 3970
500 1200 587 M2BN 587 LA 3GBN 983 510- 95.4 585 468 4630
550 1200 587 M2BN 587 LC 3GBN 983 530- 95.4 635 508 4630
600 3600 587 M2BN 587 LA 3GBN 981 510- 95.8 635 508 4740
600 1800 587 M2BN 587 LA 3GBN 982 510- 95.8 670 536 4630
650 3600 587 M2BN 587 LC 3GBN 981 530- 95.8 690 552 4740
650 1800 587 M2BN 587 LB 3GBN 982 520- 96.2 715 572 4740
700 1800 587 M2BN 587 LC 3GBN 982 530- 96.2 760 608 4630
1)
Efficiency and full load current at 60 Hz, sine wave. NEMA nominal efficiency according to IEEE 112.
EPAct is applicable on motors up to 200 HP.
The bullet indicates a 3-letter supplement for choice of mounting arrangement,
voltage and frequency, and generation code, see ordering information page.
ABB /Cat. BU/NEMA GB 10-2004 9
NEMA LV Motors, Inverter Duty Constant Torque 4:1 (60 - 15 Hz)
Cast Iron, Three phase, TEFC
For IGBT Power, Switching frequency 3 kHZ (average)
460 V, IP 55, S.F. 1.0 on VFD, 40C ambient
1)
Efficiency FL Current 1)
460 V 575 V
Output Speed Frame Motor Product FL IN IN Weight
HP r/min size type code % A A lbs
100 3600 405TS M2BN 405 MB 3GBN 801 320- 93.6 109 83 1025
100 1800 405T M2BN 405 MB 3GBN 802 320- 94.5 116 93 1025
100 1200 444T M2BN 444 SC 3GBN 843 130- 94.1 118 95 1460
100 900 445T M2BN 445MD 3GBN 844 340- 93.0 121 97 1570
125 3600 444TS M2BN 444 SB 3GBN 841 120- 94.5 141 113 1390
125 1800 444T M2BN 444 SB 3GBN 842 120- 94.5 143 115 1390
125 1200 445T M2BN 445 MD 3GBN 843 340- 94.1 147 118 1570
125 900 447/9T M2BN 449 KHB 3GBN 844 720- 93.6 153 123 2120
125 900 505T M2BN 505 MB 3GBN 904 320- 93.6 153 123 2010
150 3600 445TS M2BN 445 MC 3GBN 841 330- 94.5 167 134 1520

1 150
150
150
150
1800
1200
1200
900
445T
447/9T
505T
447/9T
M2BN
M2BN
M2BN
M2BN
445
449
505
449
MC
KHB
MB
KHC
3GBN
3GBN
3GBN
3GBN
842
843
903
844
330-
720-
320-
730-
95.0
95.0
95.0
93.6
169
176
176
181
136
141
141
145
1520
2120
2010
2380
150 900 506T M2BN 506 LA 3GBN 904 510- 93.6 181 145 2320
200 3600 447/9TS M2BN 449 KHA 3GBN 841 710- 95.0 229 184 2140
200 3600 505TS M2BN 505 MB 3GBN 901 320- 95.0 229 184 2030
200 1800 447/9T M2BN 449 KHA 3GBN 842 710- 95.0 230 184 2180
200 1800 505T M2BN 505 MB 3GBN 902 320- 95.0 230 184 2040
200 1200 447/9T M2BN 449 KHC 3GBN 843 730- 95.0 236 189 2380
200 1200 506T M2BN 506 LA 3GBN 903 510- 95.0 236 189 2320
200 900 447/9T M2BN 449 KHD 3GBN 844 740- 94.1 243 195 2670
200 900 586 M2BN 585 S 3GBN 984 100- 94.1 248 199 3420
250 3600 447/9TS M2BN 449 KHB 3GBN 841 720- 95.4 276 221 2310
250 3600 505TS M2BN 505 MC 3GBN 901 330- 95.4 276 221 2230
250 1800 447/9T M2BN 449 KHB 3GBN 842 720- 95.4 287 230 2270
250 1800 505T M2BN 505 MC 3GBN 902 330- 95.4 287 230 2140
250 1200 447/9T M2BN 449 KHD 3GBN 843 740- 95.4 296 237 2580
250 1200 585 M2BN 585 S 3GBN 983 100- 95.0 290 232 3420
250 900 586 M2BN 586 MA 3GBN 984 310- 94.5 310 248 3970
300 3600 447/9TS M2BN 449 KHC 3GBN 841 730- 95.4 330 264 2540
300 3600 506TS M2BN 506 LA 3GBN 901 510- 95.4 330 264 2580
300 1800 447/9T M2BN 449 KHC 3GBN 842 730- 95.8 344 276 2490
300 1800 506T M2BN 506 LA 3GBN 902 510- 95.8 344 276 2380
300 1200 447/9T M2BN 449 KHE 3GBN 843 750- 95.4 350 280 2840
300 1200 586 M2BN 586 MA 3GBN 983 310- 95.4 345 276 3970
300 900 587 M2BN 587 LA 3GBN 984 510- 94.5 390 312 4630
350 3600 447/9TS M2BN 449 KHD 3GBN 841 740- 95.8 380 304 2670
350 1800 447/9T M2BN 449 KHD 3GBN 842 740- 95.4 400 320 2620
400 3600 447/9TS M2BN 449 KHE 3GBN 841 750- 95.8 432 346 2820
400 3600 585 M2BN 585 S 3GBN 981 100- 95.4 430 344 3420
400 1800 447/9T M2BN 449 KHE 3GBN 842 750- 95.8 455 364 2780
400 1800 585 M2BN 585 S 3GBN 982 100- 95.4 455 364 3420
400 1200 586 M2BN 586 MB 3GBN 983 320- 95.4 470 376 3970
400 900 587 M2BN 587 LC 3GBN 984 530- 94.5 480 384 4630
500 3600 586 M2BN 586 MA 3GBN 981 310- 95.4 530 424 3860
500 1800 586 M2BN 586 MA 3GBN 982 310- 95.8 560 448 3970
500 1200 587 M2BN 587 LA 3GBN 983 510- 95.4 585 468 4630
550 1200 587 M2BN 587 LC 3GBN 983 530- 95.4 635 508 4630
600 3600 587 M2BN 587 LA 3GBN 981 510- 95.8 635 508 4740
600 1800 587 M2BN 587 LA 3GBN 982 510- 95.8 670 536 4630
650 3600 587 M2BN 587 LC 3GBN 981 530- 95.8 690 552 4740
650 1800 587 M2BN 587 LB 3GBN 982 520- 96.2 715 572 4740
700 1800 587 M2BN 587 LC 3GBN 982 530- 96.2 760 608 4630
1)
Efficiency and full load current at 60 Hz, sine wave. NEMA nominal efficiency according to IEEE 112.
The bullet indicates a 3-letter supplement for choice of mounting arrangement, EPAct is applicable on motors up to 200 HP.
voltage and frequency, and generation code, see ordering information page.

10 ABB /Cat. BU/NEMA GB 10-2004


NEMA LV Motors, Inverter Duty Constant Torque 10:1 (60 - 6 Hz)
Cast Iron, Three phase, TEFC
For IGBT Power, Switching frequency 3 kHZ (average)
460 V, IP 55, S.F. 1.0 on VFD, 40C ambient
1)
Efficiency FL Current 1)
460 V 575 V
Output Speed Frame Motor Product FL IN IN Weight
HP r/min size type code % A A lbs
75 3600 405TS M2BN 405 MB 3GBN 801 320- 93.6 84 68 1025
75 1800 405T M2BN 405 MB 3GBN 802 320- 94.5 89 72 1025
75 1200 444T M2BN 444 SC 3GBN 843 130- 94.1 90 72 1460
75 900 445T M2BN 445MD 3GBN 844 340- 93.0 97 78 1570
100 3600 444TS M2BN 444 SB 3GBN 841 120- 94.5 115 92 1390
100 1800 444T M2BN 444 SB 3GBN 842 120- 94.5 116 93 1390
100 1200 445T M2BN 445 MD 3GBN 843 340- 94.1 121 97 1570
100 900 447/9T M2BN 449 KHB 3GBN 844 720- 93.6 130 104 2120
100 900 505T M2BN 505 MB 3GBN 904 320- 93.6 130 104 2010
125 3600 445TS M2BN 445 MC 3GBN 841 330- 94.5 141 113 1520
125
125
125
125
1800
1200
1200
900
445T
447/9T
505T
447/9T
M2BN
M2BN
M2BN
M2BN
445
449
505
449
MC
KHB
MB
KHC
3GBN
3GBN
3GBN
3GBN
842
843
903
844
330-
720-
320-
730-
95.0
95.0
95.0
93.6
143
149
149
154
115
120
120
124
1520
2120
2010
2380
1
125 900 506T M2BN 506 LA 3GBN 904 510- 93.6 154 124 2320
150 3600 447/9TS M2BN 449 KHA 3GBN 841 710- 95.0 175 140 2140
150 3600 505TS M2BN 505 MB 3GBN 901 320- 95.0 175 140 2030
150 1800 447/9T M2BN 449 KHA 3GBN 842 710- 95.0 178 143 2180
150 1800 505T M2BN 505 MB 3GBN 902 320- 95.0 178 143 2040
150 1200 447/9T M2BN 449 KHC 3GBN 843 730- 95.0 182 146 2380
150 1200 506T M2BN 506 LA 3GBN 903 510- 95.0 182 146 2320
150 900 447/9T M2BN 449 KHD 3GBN 844 740- 94.1 192 154 2670
150 900 586 M2BN 585 S 3GBN 984 100- 94.1 196 157 3420
200 3600 447/9TS M2BN 449 KHB 3GBN 841 720- 95.4 226 181 2310
200 3600 505TS M2BN 505 MC 3GBN 901 330- 95.4 226 181 2230
200 1800 447/9T M2BN 449 KHB 3GBN 842 720- 95.4 233 187 2270
200 1800 505T M2BN 505 MC 3GBN 902 330- 95.4 233 187 2140
200 1200 447/9T M2BN 449 KHD 3GBN 843 740- 95.4 241 193 2580
200 1200 585 M2BN 585 S 3GBN 983 100- 95.0 239 192 3420
200 900 586 M2BN 586 MA 3GBN 984 310- 94.5 258 207 3970
250 3600 447/9TS M2BN 449 KHC 3GBN 841 730- 95.4 274 220 2540
250 3600 506TS M2BN 506 LA 3GBN 901 510- 95.4 274 220 2580
250 1800 447/9T M2BN 449 KHC 3GBN 842 730- 95.8 293 235 2490
250 1800 506T M2BN 506 LA 3GBN 902 510- 95.8 293 235 2380
250 1200 447/9T M2BN 449 KHE 3GBN 843 750- 95.4 299 240 2840
250 1200 586 M2BN 586 MA 3GBN 983 310- 95.4 294 236 3970
250 900 587 M2BN 587 LA 3GBN 984 510- 94.5 343 275 4630
280 3600 447/9TS M2BN 449 KHD 3GBN 841 740- 95.8 310 248 2670
280 1800 447/9T M2BN 449 KHD 3GBN 842 740- 95.4 327 262 2620
300 3600 447/9TS M2BN 449 KHE 3GBN 841 750- 95.8 322 258 2820
300 3600 585 M2BN 585 S 3GBN 981 100- 95.4 320 256 3420
300 1800 447/9T M2BN 449 KHE 3GBN 842 750- 95.8 351 281 2780
300 1800 585 M2BN 585 S 3GBN 982 100- 95.4 343 275 3420
300 1200 586 M2BN 586 MB 3GBN 983 320- 95.4 368 295 3970
300 900 587 M2BN 587 LC 3GBN 984 530- 94.5 384 308 4630
400 3600 586 M2BN 586 MA 3GBN 981 310- 95.4 428 343 3860
400 1800 586 M2BN 586 MA 3GBN 982 310- 95.8 458 367 3970
400 1200 587 M2BN 587 LA 3GBN 983 510- 95.4 482 386 4630
440 1200 587 M2BN 587 LC 3GBN 983 530- 95.4 534 428 4630
450 3600 587 M2BN 587 LA 3GBN 981 510- 95.8 479 384 4740
450 1800 587 M2BN 587 LA 3GBN 982 510- 95.8 519 416 4630
500 3600 587 M2BN 587 LC 3GBN 981 530- 95.8 535 428 4740
500 1800 587 M2BN 587 LB 3GBN 982 520- 96.2 565 452 4740
550 1800 587 M2BN 587 LC 3GBN 982 530- 96.2 622 498 4630
1)
Efficiency and full load current at 60 Hz, sine wave. NEMA nominal efficiency according to IEEE 112.
The bullet indicates a 3-letter supplement for choice of mounting arrangement, EPAct is applicable on motors up to 200 HP.
voltage and frequency, and generation code, see ordering information page.

ABB /Cat. BU/NEMA GB 10-2004 11


NEMA LV Motors, Inverter Duty Constant Torque 1000:1 (60 - 0 Hz)
Cast Iron, Three phase, TEFC
For IGBT Power, Switching frequency 3 kHZ (average)
460 V, IP 55, S.F. 1.0 on VFD, 40C ambient
1)
Efficiency FL Current 1)
460 V 575 V
Output Speed Frame Motor Product FL IN IN Weight
HP r/min size type code % A A lbs
100 3600 405TS M2BN 405 MB 3GBN 801 320- 93.6 109 88 1025
100 1800 405T M2BN 405 MB 3GBN 802 320- 94.5 116 93 1025
100 1200 444T M2BN 444 SC 3GBN 843 130- 94.1 118 95 1460
100 900 445T M2BN 445MD 3GBN 844 340- 93.0 121 97 1570
125 3600 444TS M2BN 444 SB 3GBN 841 120- 94.5 141 113 1390
125 1800 444T M2BN 444 SB 3GBN 842 120- 94.5 143 115 1390
125 1200 445T M2BN 445 MD 3GBN 843 340- 94.1 147 118 1570
125 900 447/9T M2BN 449 KHB 3GBN 844 720- 93.6 153 123 2120
125 900 505T M2BN 505 MB 3GBN 904 320- 93.6 153 123 2010
150 3600 445TS M2BN 445 MC 3GBN 841 330- 94.5 167 134 1520

1 150
150
150
150
1800
1200
1200
900
445T
447/9T
505T
447/9T
M2BN
M2BN
M2BN
M2BN
445
449
505
449
MC
KHB
MB
KHC
3GBN
3GBN
3GBN
3GBN
842
843
903
844
330-
720-
320-
730-
95.0
95.0
95.0
93.6
169
176
176
181
136
141
141
145
1520
2120
2010
2380
150 900 506T M2BN 506 LA 3GBN 904 510- 93.6 181 145 2320
200 3600 447/9TS M2BN 449 KHA 3GBN 841 710- 95.0 229 184 2140
200 3600 505TS M2BN 505 MB 3GBN 901 320- 95.0 229 184 2030
200 1800 447/9T M2BN 449 KHA 3GBN 842 710- 95.0 230 184 2180
200 1800 505T M2BN 505 MB 3GBN 902 320- 95.0 230 184 2040
200 1200 447/9T M2BN 449 KHC 3GBN 843 730- 95.0 236 189 2380
200 1200 506T M2BN 506 LA 3GBN 903 510- 95.0 236 189 2320
200 900 447/9T M2BN 449 KHD 3GBN 844 740- 94.1 243 195 2670
200 900 586 M2BN 585 S 3GBN 984 100- 94.1 248 199 3420
250 3600 447/9TS M2BN 449 KHB 3GBN 841 720- 95.4 276 221 2310
250 3600 505TS M2BN 505 MC 3GBN 901 330- 95.4 276 221 2230
250 1800 447/9T M2BN 449 KHB 3GBN 842 720- 95.4 287 230 2270
250 1800 505 T M2BN 505 MC 3GBN 902 330- 95.4 287 230 2140
250 1200 447/9T M2BN 449 KHD 3GBN 843 740- 95.4 296 237 2580
250 1200 585 M2BN 585 S 3GBN 983 100- 95.0 290 232 3420
250 900 586 M2BN 586 MA 3GBN 984 310- 94.5 310 248 3970
300 3600 447/9TS M2BN 449 KHC 3GBN 841 730- 95.4 330 264 2540
300 3600 506TS M2BN 506 LA 3GBN 901 510- 95.4 330 264 2580
300 1800 447/9T M2BN 449 KHC 3GBN 842 730- 95.8 344 276 2490
300 1800 506T M2BN 506 LA 3GBN 902 510- 95.8 344 276 2380
300 1200 447/9T M2BN 449 KHE 3GBN 843 750- 95.4 350 280 2840
300 1200 586 M2BN 586 MA 3GBN 983 310- 95.4 345 276 3970
300 900 587 M2BN 587 LA 3GBN 984 510- 94.5 390 312 4630
350 3600 447/9TS M2BN 449 KHD 3GBN 841 740- 95.8 380 304 2670
350 1800 447/9T M2BN 449 KHD 3GBN 842 740- 95.4 400 320 2620
400 3600 447/9TS M2BN 449 KHE 3GBN 841 750- 95.8 432 346 2820
400 3600 585 M2BN 585 S 3GBN 981 100- 95.4 430 344 3420
400 1800 447/9T M2BN 449 KHE 3GBN 842 750- 95.8 455 364 2780
400 1800 585 M2BN 585 S 3GBN 982 100- 95.4 455 364 3420
400 1200 586 M2BN 586 MB 3GBN 983 320- 95.4 470 376 3970
400 900 587 M2BN 587 LC 3GBN 984 530- 94.5 480 384 4630
500 3600 586 M2BN 586 MA 3GBN 981 310- 95.4 530 424 3860
500 1800 586 M2BN 586 MA 3GBN 982 310- 95.8 560 448 3970
500 1200 587 M2BN 587 LA 3GBN 983 510- 95.4 585 468 4630
550 1200 587 M2BN 587 LC 3GBN 983 530- 95.4 635 508 4630
600 3600 587 M2BN 587 LA 3GBN 981 510- 95.8 635 508 4740
600 1800 587 M2BN 587 LA 3GBN 982 510- 95.8 670 536 4630
650 3600 587 M2BN 587 LC 3GBN 981 530- 95.8 690 552 4740
650 1800 587 M2BN 587 LB 3GBN 982 520- 96.2 715 572 4740
700 1800 587 M2BN 587 LC 3GBN 982 530- 96.2 760 608 4630
1)
Efficiency and full load current at 60 Hz, sine wave. NEMA nominal efficiency according to IEEE 112.
The bullet indicates a 3-letter supplement for choice of mounting arrangement, EPAct is applicable on motors up to 200 HP.
voltage and frequency, and generation code, see ordering information page.

12 ABB /Cat. BU/NEMA GB 10-2004


NEMA LV cast iron motors - Variant codes
Code1) Variant M2BA/M2BN
40_ - 44_ 50_ 58_

Balancing
052 Vibration to Grade A (IEC 60034-14). S S S
417 Vibration to Grade B (IEC 60034-14). P P P

Bearings and Lubrication


037 Roller bearings at D-end. M M M
043 SPM nipples. M S S
107 Bearing mounted PT100 resistance elements. P P P
420 Bearing mounted PTC thermistors. P P P

Branch standard designs


178 Stainless steel / acid proof bolts. P P P
425 Corrosion protected stator and rotor core. P P P

183
Cooling system
Separate motor cooling (fan axial, N-end). P P P
1
422 Separate motor cooling (fan top or side, N-end). P P P

Drain holes
065 Plugged existing drain holes. M M M
066 Modified drain hole position (for specified IM xxxx). P P P
076 Draining holes with plugs. Felt plugs. S S S

Earthing bolt
067 External earthing bolt. S S S

Heating elements
450 Heating element, 100-120 V. P P P
451 Heating element, 200-240 V. M M M

Mounting arrangements
063 Flange mounted, NEMA C-flange. P P P
064 Flange mounted, NEMA D-flange. P P P

Painting
114 Special paint colour, standard grade. M M M

Protection
005 Protective roof, vertical motor, shaft down. P P P
072 Radial seal at D-end. M M M

Rating & instruction plates


138 Mounting of additional identification plate, aluminum. M M M
161 Additional rating plate delivered loose. M M M

Stator winding temperature sensors


121 Bimetal detectors, break type (NCC), (3 in series), 130C, in stator winding. M M M
122 Bimetal detectors, break type (NCC), (3 in series), 150C, in stator winding. M M M
123 Bimetal detectors, break type (NCC), (3 in series), 170C, in stator winding. M M M
125 Bimetal detectors, break type (NCC), (2x3 in series), 150C, in stator winding. M M M

1)
Certain variant codes cannot be used simultaneously. S = Included as standard. M = On modification of a stocked
P = New manufacture only. motor, or on new manufacture, the
number per order may be limited.

ABB /Cat. BU/NEMA GB 10-2004 13


Code1) Variant M2BA/M2BN
40_ - 44_ 50_ 58_
127 Bimetal detectors, break type (NCC), (3 in series, 130C, and 3 in series, 150C),
in stator winding. M M M
321 Bimetal detectors, closing type (NO), (3 in parallel), 130C, in stator winding. M M M
322 Bimetal detectors, closing type (NO), (3 in parallel), 150C, in stator winding. M M M
323 Bimetal detectors, closing type (NO), (3 in parallel), 170C, in stator winding. M M M
325 Bimetal detectors, closing type (NO),(2x3 in parallel), 150C, in stator winding. M M M
327 Bimetal detectors, closing type (NO), (3 in parallel, 130C, and 3 in parallel, 150C),
in stator winding. M M M
435 PTC-thermistors (3 in series), 130C, in stator winding. M M M
436 PTC-thermistors (3 in series), 150C, in stator winding. S S S
437 PTC-thermistors (3 in series), 170C, in stator winding. M M M
439 PTC-thermistors (2x3 in series), 150C, in stator winding. M M M
441 PTC-thermistors (3 in series, 130C and 3 in series, 150C), in stator winding. M M M
442 PTC-thermistors (3 in series, 150C and 3 in series, 170C), in stator winding. M M M
445 PT100 (1 per phase), in stator winding. M M M

1 446 PT100 (2 per phase), in stator winding.

Terminal box
M M M

418 Separate terminal box for temperature detectors. M M M

Variable speed drives


Mounting of tacho; tacho not included
182 Pulse sensor mounted as specified (Leine & Linde equivalent, hollow shaft type). P P P
470 Prepared for hollow shaft pulse tacho (Leine & Linde equivalent). P P P
Mounting of tacho; tacho included
472 1024 hollow shaft pulse tacho (Leine & Linde equivalent) mounted. P P P
473 2048 hollow shaft pulse tacho (Leine & Linde equivalent) mounted. P P P
748 Pulse tacho Lake Shore (RIM 8500) mounted. P P P
749 Pulse tacho Avtron (M285) mounted. P P P
Separate motor cooling & prepared for tacho; tacho not included
478 Separate motor cooling (fan top, N-end) and prepared for hollow P P P
shaft pulse tacho (Leine & Linde equivalent).
474 Separate motor cooling (fan axial, N-end) and prepared for hollow P P P
shaft pulse tacho (Leine & Linde equivalent).
487 Separate motor cooling (fan axial, N-end) and prepared for hollow P P P
shaft pulse tacho (Lake Shore RIM 8500 or Avtron M285).
Separate motor cooling & prepared for tacho; tacho included
428 Separate motor cooling (fan top, N-end) and Leine & Linde, type P P P
510, pulse tacho.
429 Separate motor cooling (fan top, N-end) and Leine & Linde, type P P P
861, pulse tacho.
475 Separate motor cooling (fan axial, N-end) and 512 hollow shaft pulse tacho P P P
(Leine & Linde equivalent).
476 Separate motor cooling (fan axial, N-end) and 1024 hollow shaft pulse tacho P P P
(Leine & Linde equivalent).
477 Separate motor cooling (fan axial, N-end) and 2048 hollow shaft pulse tacho P P P
(Leine & Linde equivalent).
488 Separate motor cooling (fan axial, N-end) and Lake Shore P P P
RIM 8500 pulse tacho mounted.
489 Separate motor cooling (fan axial, N-end) and Avtron M285 P P P
pulse tacho mounted.
701 Insulated bearing at N-end. Standard from size 449 in inverter duty. P P P
1)
Certain variant codes cannot be used simultaneously. S = Included as standard. M = On modification of a stocked
P = New manufacture only. motor, or on new manufacture, the
number per order may be limited.

14 ABB /Cat. BU/NEMA GB 10-2004


NEMA LV Cast iron motors Sizes 444TS - 587
Dimension drawings, Foot-mounted motors

1
Frame Type
size M2BA Poles A AB B BA C D 2E 2F G H
444TS 444 S_ 2 21 19.2 20 7.5 42.1 11 18 14.5 1.57 0.81
444T 4... 21 19.2 20 7.5 45.9 11 18 14.5 1.57 0.81
445TS 445 M_ 2 21 19.2 20 7.5 42.1 11 18 16.5 1.57 0.81
445T 4... 21 19.2 20 7.5 45.9 11 18 16.5 1.57 0.81
449TS 449 KH_ 2 21 21.6 29 7.5 50.44 11 18 25 1.18 0.81
449T 4... 21 21.6 29 7.5 54.2 11 18 25 1.18 0.81
505T 505 M _ 2 23.2 21.6 21.9 8.5 45.42 12.5 20 18 2 1.19
505T 4... 23.2 21.6 21.9 8.5 49.2 12.5 20 18 2 1.19
506 506 L_ 2 23.2 21.61 23.9 8.5 47.5 12.5 20 20 2 1.19
506 4... 23.2 21.61 23.9 8.5 51.2 12.5 20 20 2 1.19
585 585 S_ 2 27.6 24.68 26.06 10 52.15 14.5 24 20 2.7 1.25
585 4... 27.6 24.68 26.06 10 56 14.5 24 20 2.7 1.25
586 586 M_ 2 27.6 24.68 28.41 10 54.2 14.5 24 22 2.7 1.25
586 4... 27.6 24.5 28.41 10 57.95 14.5 24 22 2.7 1.25
587 587 L_ 2 27.6 24.68 31.2 10 58.4 14.5 24 25 2.7 1.25
587 4... 27.6 24.5 31.2 10 62.1 14.5 24 25 2.7 1.25

Frame Type
size M2BA Poles J K V O P T U 1) Key
444TS 444 S_ 2 3.4 5.3 4.75 22.3 22.5 3.7 2 3/8 = 2.375 0.625
444T 4... 3.4 5.3 8.5 22.3 22.5 3.7 3 3/8 = 3.375 0.875
445TS 445 M_ 2 3.4 5.3 4.75 22.3 22.5 3.7 2 3/8 = 2.375 0.625
445T 4... 3.4 5.3 8.5 22.3 22.5 3.7 3 3/8 = 3.375 0.875
449TS 449 KH_ 2 3.35 - 4.75 23.7 25.4 3.7 2 3/8 = 2.375 0.625
449T 4... 3.35 - 8.5 23.7 25.4 3.7 3 3/8 = 3.375 0.875
505T 505 M _ 2 4 6.4 4.75 25.2 25.4 3.7 2 3/8 = 2.375 0.625
505T 4... 4 6.4 8.5 25.2 25.4 3.7 3 3/8 = 3.375 0.875
506 506 L_ 2 4 6.4 4.75 25.2 25.4 3.7 2 3/8 = 2.375 0.625
506 4... 4 6.4 8.5 25.2 25.4 3.7 3 3/8 = 3.375 0.875
585 585 S_ 2 4.7 6.4 4.75 29.1 29 4.3 2 3/8 = 2.375 0.625
585 4... 4.7 6.4 8.5 29.1 29 4.3 3 3/8 = 3.375 0.875
586 586 M_ 2 4.7 6.4 4.75 29.22 29 4.3 2 3/8 = 2.375 0.625
586 4... 4.72 6.4 8.5 29.22 29.14 4.3 3 3/8 = 3.375 0.875
587 587 L_ 2 4.7 6.4 4.75 29.22 29 4.3 2 3/8 = 2.375 0.625
587 4... 4.72 6.4 8.5 29.22 29.14 4.3 3 3/8 = 3.375 0.875
1)
Tolerances acc. to IEC. Dimensions in inches.
NEMA tolerances on request. Dimension prints on motors with terminal box on top on request.
2.375 = + 0, - 0.001
3.375 = + 0, - 0.001

ABB /Cat. BU/NEMA GB 10-2004 15


NEMA LV Cast iron motors Sizes 444S - 506L
Dimension drawings, Flange-mounted motor

C Face

1 Type
M2BA Poles AB AJ AK BB BD BF BV C P U 1) V Key

444 S_ , 445 M_ 2 18.3 14 16 0.25 18 5/8-11 12.3 41.7 22.5 2.375 4.75 0.63
4... 18.3 14 16 0.25 18 5/8-11 16.1 45.5 22.5 3.375 8.5 0.88

D Flange

Type
M2BA Poles AB AJ AK BB BD BF BV C P U 1) V Key

444 S_ , 445 M_ 2 18.3 20 18 0.25 21.7 0.81 12.3 41.70 22.50 2.375 4.75 0.625
4... 18.3 20 18 0.25 21.7 0.81 16.1 45.50 22.50 3.375 8.5 0.875
449 KH_ 2 18.3 20 18 0.25 21.7 0.81 13.1 50.50 25.40 2.375 4.75 0.625
4... 18.3 20 18 0.25 21.7 0.81 16.8 54.22 25.40 3.375 8.5 0.875
505 M_ 2 20.7 22 18 0.25 25 0.81 12.9 45.43 25.40 2.375 4.75 0.625
4... 20.7 22 18 0.25 25 0.81 16.6 49.20 25.40 3.375 8.5 0.875
506 L_ 2 20.7 22 18 0.25 25 0.81 12.86 47.44 25.40 2.375 4.75 0.625
4... 20.7 22 18 0.25 25 0.81 16.6 51.20 25.40 3.375 8.5 0.875

1)
Tolerances acc. to IEC: Dimensions in inches.
NEMA tolerances on request.
2.375 = + 0, - 0.001
3.375 = + 0, - 0.001

16 ABB /Cat. BU/NEMA GB 10-2004


NEMA LV motors, Inverter duty Sizes M2BN 404 - 587
Dimension drawings, Foot-mounted motors

Frame Type
size M2BN Poles A AB AB1 B BA C D 2E 2F G H J K V O P T U 1) Key

404TS 404 S_ 2 19.45 17.56 12 16.38 6.62 39.1 10 16 12.25 1.6 0.81 3.4 5.35 4.25 19.92 19.45 2.8 2 1/8=2.125 0.5
404T 4... 19.45 17.56 12 16.38 6.62 42.1 10 16 12.25 1.6 0.81 3.4 5.35 7.25 19.92 19.45 2.8 2 7/8=2.875 0.75
405TS 405 M_ 2 19.45 17.56 12 16.38 6.62 39.1 10 16 13.75 1.6 0.81 3.4 5.35 4.25 19.92 19.45 2.8 2 1/8=2.125 0.5
405T 4... 19.45 17.56 12 16.38 6.62 42.1 10 16 13.75 1.6 0.81 3.4 5.35 7.25 19.92 19.45 2.8 2 7/8=2.875 0.75
444TS 444 S_ 2 21 19.17 13.5 20 7.5 45.4 11 18 14.5 1.57 0.81 3.4 5.28 4.75 22.26 22.5 3.7 2 3/8=2.375 0.625
444T 4... 21 19.17 13.5 20 7.5 49.2 11 18 14.5 1.57 0.81 3.4 5.28 8.5 22.26 22.5 3.7 3 3/8=3.375 0.875
445TS 445 M_ 2 21 19.17 13.5 20 7.5 45.4 11 18 16.5 1.57 0.81 3.4 5.28 4.75 22.26 22.5 3.7 2 3/8=2.375 0.625
445T 4... 21 19.17 13.5 20 7.5 49.2 11 18 16.5 1.57 0.81 3.4 5.28 8.5 22.26 22.5 3.7 3 3/8=3.375 0.875
447TS 449 KH_ 2 21 21.61 15 29 7.5 53.8 11 18 20 1.19 0.81 3.4 - 4.75 27.5 25.4 3.7 2 3/8=2.375 0.625
447T 4... 21 21.61 15 29 7.5 57.5 11 18 20 1.19 0.81 3.4 - 8.5 27.5 35.4 3.7 3 3/8=3.375 0.875
449TS 449 KH_ 2 21 21.66 15 29 7.5 53.8 11 18 25 1.19 0.81 3.4 - 4.75 27.5 25.4 3.7 2 3/8=2.375 0.625
449T 4... 21 21.66 15 29 7.5 57.5 11 18 25 1.19 0.81 3.4 - 8.5 27.5 25.4 3.7 3 3/8=3.375 0.875
505T 505 M _ 2 23.2 21.61 15 21.9 8.5 48.7 12.5 20 18 2 1.19 4 6.4 4.75 25.1 25.4 3.7 2 3/8=2.375 0.625
505T 4... 23.2 21.61 15 21.9 8.5 52.5 12.5 20 18 2 1.19 4 6.4 8.5 25.1 25.4 3.7 3 3/8=3.375 0.875
506 506 L_ 2 23.2 21.61 15 23.9 8.5 50.8 12.5 20 20 2 1.19 4 6.4 4.75 25.1 25.4 3.7 2 3/8=2.375 0.625
506 4... 23.2 21.61 15 23.9 8.5 54.5 12.5 20 20 2 1.19 4 6.4 8.5 25.1 25.4 3.7 3 3/8=3.375 0.875
585 585 S_ 2 27.6 24.68 17 26.06 10 55.8 14.5 24 20 2.7 1.25 4.7 6.4 4.75 29.1 29 4.3 2 3/8=2.375 0.625
585 4... 27.6 24.68 17 26.06 10 59.5 14.5 24 20 2.7 1.25 4.7 6.4 8.5 29.1 29 4.3 3 3/8=3.375 0.875
586 586 M_ 2 27.6 24.68 17 28.4 10 57.8 14.5 24 22 2.7 1.25 4.7 6.4 4.75 29.1 29 4.3 2 3/8=2.375 0.625
586 4... 27.6 24.68 17 28.4 10 61.6 14.5 24 22 2.7 1.25 4.7 6.4 8.5 29.1 29 4.3 3 3/8=3.375 0.875
587 587 L_ 2 27.6 24.68 17 31.2 10 62 14.5 24 25 2.7 1.25 4.7 6.4 4.75 29.1 29 4.3 2 3/8=2.375 0.625
587 4... 27.6 24.68 17 31.2 10 65.8 14.5 24 25 2.7 1.25 4.7 6.4 8.5 29.1 29 4.3 3 3/8=3.375 0.875
1)
Tolerances acc. to IEC: Dimensions in inches.
NEMA tolerances on request. Dimension prints on motors with terminal box on top on request.
2.125 = + 0.0012, + 0.0004
2.875 = + 0.0012, + 0.0004
2.375 = + 0.0012, + 0.0004
3.375 = + 0.0014, + 0.0005

ABB /Cat. BU/NEMA GB 10-2004 17


NEMA LV motors, Inverter duty Sizes M2BN 404 - 587
Dimension drawings, Flange-mounted motors
C Face Motors

1 Motor type
M2BN Poles AB AB1 AJ AK BB BD BF BV C P U 1) V Key

404 S_ , 405 M_ 2 16.80 12.0 11 12.5 0.25 15.5 5/8-11 11.38 39.1 19.45 2.125 4.25 0.50
4... 16.8 12.0 11 12.5 0.25 15.5 5/8-11 14.38 42.1 19.45 2.875 7.25 0.75
444 S_ , 445 M_ 2 18.3 13.5 14 16 0.25 18 5/8-11 12.3 45.4 22.50 2.375 4.75 0.63
4... 18.3 13.5 14 16 0.25 18 5/8-11 16.1 49.2 22.50 3.375 8.50 0.88

D-flange Motors

Motor type
M2BN Poles AB AB1 AJ AK BB BD BE BF BV C P U 1) V Key

404 S_ , 405 M_ 2 16.8 12 20 18 0.25 21.7 0.86 0.81 11.38 39.1 19.45 2.125 4.25 0.5
4... 16.8 12 20 18 0.25 21.7 0.86 0.81 14.38 42.1 19.45 2.875 7.25 0.75
444 S_ , 445 M_ 2 18.3 13.5 20 18 0.25 21.7 0.87 0.81 12.3 45.4 22.5 2.375 4.75 0.63
4... 18.3 13.5 20 18 0.25 21.7 0.87 0.81 16.1 49.2 22.5 3.375 8.5 0.88
449 KH_ 2 18.3 15 20 18 0.25 21.7 1 0.81 53.8 25.4 2.375 4.75 0.63
4... 18.3 15 20 18 0.25 21.7 1 0.81 57.5 25.4 3.375 8.5 0.88
504 S_ , 505 M_ 2 20.7 15 22 18 0.25 25 1 0.81 12.86 48.7 25.4 2.375 4.75 0.63
4... 20.7 15 22 18 0.25 25 1 0.81 16.6 52.5 25.4 3.375 8.5 0.88
506 L_ 2 20.7 17 22 18 0.25 25 1 0.81 12.86 50.8 25.4 2.375 4.75 0.63
4... 20.7 17 22 18 0.25 25 1 0.81 16.6 54.5 25.4 3.375 8.5 0.88
1)
Tolerances acc. to IEC: Dimensions in inches.
NEMA tolerances on request.
2.125 = + 0.0012, + 0.0004 2.375 = + 0.0012, + 0.0004
2.875 = + 0.0012, + 0.0004 3.375 = + 0.0014, + 0.0005
18 ABB /Cat. BU/NEMA GB 10-2004
NEMA LV cast iron motors in brief, basic design
Motor size 40_, 44_ 50_ 58_

Stator Material Cast iron GG 20/GRS 200


Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G, RAL 5014
Paint thickness Two-pack epoxy paint, thickness 70 m

Bearing end shields Material Cast iron GG 20/GRS 200, except flange-mounted size 355 Spheroidal graphit
GGG40/GRP400
Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G, RAL 5014
Paint thickness Two-pack epoxy paint, thickness 70 m

Bearings D-end 2-pole 6316-C4 6316-C4 6319M/C4


4-12 -pole 6316-C3 6319-C3 6322-C3
N-end 2-pole 6316-C4 6316-C4 6319M/C4
4-12 -pole 6316-C3 6316-C3 6319-C3

Axially-locked
bearings
Inner bearing cover As standard, locked at D-end
1
Bearing seals V-ring as standard, radial seal on request

Lubrication Regreasable bearings, regreasing nipples, M10x1

SPM-nipples As standard

Rating plate Material Acid proof stainless steel AISI 316 thickness 0.6 mm

Terminal box Frame material Cast iron GG 15/GRS 150


Cover material Cast iron GG 15/GRS 150
Cover screws material Steel 5G, coated with zinc and yellow cromated

Connections Cable- 2-, 4-pole 2xM63 2xM63 2x60/80


entries 6-pole 2xM63 2xM63 2x60
Terminals 6 terminals for connection with cable lugs (not included)

Fan Material Reinforced glass fiber, aluminum or polypropylene with metal hub

Fan cover Material Steel


Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G, RAL 5014
Paint thickness Two-pack epoxypolyesterpaint, thickness 80 m

Stator winding Material Copper


Insulation Insulation class F
Winding protection 3 pcs thermistors as standard

Rotor winding Material Pressure die-cast aluminum or copper

Balancing method Half key balancing as standard

Key ways Open key way

Heating elements 50 W 2x50 W 2x65 W

Drain holes As standard, open on delivery

Enclosure IP 55, higher protection on request

Cooling method IC 411

ABB /Cat. BU/NEMA GB 10-2004 19


1

20 ABB /Cat. BU/NEMA GB 10-2004


DriveIT High Voltage NEMA Motors

Totally enclosed squirrel cage three phase high


voltage motors,
Sizes 506AT-688, 125 to 600 HP

Mechanical design............................ 22
Ordering information........................ 31
Technical data.................................... 32
Variant codes......................................36
Dimension drawings.........................37
Rating plates.......................................39
Construction.......................................40
Cast iron motors in brief..................41

ABB /Cat. BU/NEMA GB 10-2004 21


Mechanical design
This is a standard NEMA motor catalogue with limited engineered cast iron motor, please contact your local ABB
optional features and accessories. In case you need an Sales office for further information.

Stator frame
The motor frames including feet and bearing housing are Motors can be supplied for foot mounting (F1 & F2).
made of cast iron. Terminal box is made of structural
steel. Integrally cast feet allow a very rigid mounting and
minimal vibration.

Drain holes
All the high voltage motors are fitted with drain holes and In very dusty environments, both plugs should be
closable plugs. The plugs are open on delivery. When hammered home.
mounting the motors, ensure that the drain holes face
downwards.

Motor sizes 506AT-688


As standard with drain holes and closable plugs.

22 ABB /Cat. BU/NEMA GB 10-2004


Terminal boxes
NEMA terminal boxes for M3BM and M3GM motors.

Type I
Technical data: Materials:
Voltage (max.) 4.8 kV Box welded sheet steel
Current (max.) 700 A (thickness min. 3 mm (0.12"))
No of cables (max.) 2 per phase Cable gland plate steel
Cross section of cables (max.) 300 mm2/cable (0.465 in2) Grounding pad stainless steel
Cable gland blind gland (1 pce)
Gross volume 98.3 dm3 (6000 in3) Other features:
Ground connections M12 (inside) - rigid welded construction
Weight 42 kg (92 lbs) - box turnable to allow cable entry from left or right side
Protection IP 66 - box turnable in steps of 90.
Standard NEMA MG 1, Part 20

Type I terminal box.

ABB /Cat. BU/NEMA GB 10-2004 23


Type II

Technical data: Materials:


Voltage (max.) 6.9 kV Box welded sheet steel
Current (max.) 600 A (thickness min. 3 mm (0.12"))
No of cables (max.) 2 per phase Cable gland plate steel
Cross section of cables (max.) 300 mm2/cable (0.465 in2) Connection hooks Copper Cu
Cable gland blind gland (1 pce) Isolators epoxy casting resin
Connection hooks 0.3" x 2.36" (3 pcs) Grounding pad stainless steel
Clearance (min.) 149.8 mm (5.9 in)
Creepage (min.) 249 mm (10 in) Other features:
Usable volume 0.295 m3 (18 000 in3) - rigid welded construction
Ground connections M16 (both in- and - ample size for making connections of supply cables
outside) - box turnable to allow cable entry from left or right side
Weight 105 kg (230 lbs) - box turnable in steps of 90.
Protection IP 66
Standard NEMA MG 1, Part 20

Type II terminal box.

24 ABB /Cat. BU/NEMA GB 10-2004


Dimensions for terminal box inlet, blind flange

Type I
2

Type II

ABB /Cat. BU/NEMA GB 10-2004 25


Auxiliary boxes
Auxiliary box is used for control equipment and heating
elements.

2
- one box as default Other features:
- stator Pt-100 - equipped with assembly rail ARH 22
- bearing Pt-100 (optional, variant code 107) (DIN-35, 35 x 203 mm (1.38" x 7.99"))
- heating element (optional, variant code 450/451) - main dimensions 125 mm x 222 mm x 81 mm
- separate auxiliary box for heating element (optional, (4.92" x 8.74" x 3.19")
variant code 447) - cable gland M20
- degree of protection IP 66 (IEC 529)
Specification: - gasket material polyurethane
Material designation Al-Si10Mg (pressure die cast) - temperature resistance -50 - +140 C (material),
Material standard EN 573-3 +80 C (continuous use)
Surface treatment RAL 7001 (grey) - max. terminal blocks:
34 pcs 0.004 in2 (2.5 mm2) AWG = 14
2
28 pcs 0.006 in (4.0 mm2) AWG = 12
- weight 1.6 kg (3.53 lbs)

26 ABB /Cat. BU/NEMA GB 10-2004


Bearings
The motors are normally fitted with single-row deep bearing (NU-), higher radial forces can be handled. Roller
groove ball bearings as listed in the table below. bearings are suitable for belt drive applications.
If the bearing at the D-end is replaced with a roller

Basic version with deep groove ball bearings Version with roller bearings, variant code 037

Motor Number Deep groove ball bearings Motor Number Roller bearings, variant code 037
size of poles D-end N-end size of poles D-end

506AT 2 6316M/C3 6316M/C3 506AT 4-6 NU 319/C3


4-6 6319/C3 6316/C3 587 4-6 NU 322/C3
587 2 6316M/C3 6316M/C3 688 4-12 NU 324/C3
4-6 6322/C3 6316/C3
688 2 6317M/C3 6317M/C3
4-12 6324/C3 6319/C3

Axially-locked bearings
All motors are equipped as standard with an axially-locked N-end bearing is axially free and can take the thermal
bearing at the D-end. expansion. Note! NU-bearing is axially locked at N-end.
Bearing's outer ring is locked between bearing's covers
and tight fit of the housing.

2
Transport locking
Motors with roller bearings are fitted with a transport lock Locking may also be fitted in other cases where transport
to prevent damage to the bearings during transport. In conditions are suspected of being potentially damaging.
case of transport locked bearing, all high voltage motors
are provided with a warning sign.

ABB /Cat. BU/NEMA GB 10-2004 27


Bearing seals
All high voltage motors are equipped with labyrinth sealed
bearings.

Axially free (N-end)

Axially locked (D-end)

28 ABB /Cat. BU/NEMA GB 10-2004


Lubrication
On delivery, the motors are ready lubricated with high Motors with relubrication nipples
quality grease. The name of the grease is stamped on the For all high voltage motors the bearing system has been
lubrication plate fastened to the motor frame. See built so that a valve disc can be used to ease the
example of a lubrication plate on page 39. lubrication. Motors are lubricated while running.
More information about lubrication and greases can be Grease outlet opening has closing valves at both ends.
found in ABB's High Voltage Process Performance This should be opened before greasing and closed 1-2
Manual delivered together with the motor. hours after regreasing. Closing the valves ensures that the
construction is tight and dust or dirt cannot get inside the
bearing.

Lubrication intervals
ABB follows the L1-principle in defining lubrication interval. The table below gives lubrication intervals according to the
That means that 99% of the motors are sure to make the L1-principle for different speeds. The values are valid for
interval time. The lubrication intervals can also be horizontal mounted motors (B3), using high quality lithium
calculated according to the L10-principle, which are grease.
normally doubled compared to L1-values. Values are
For more information, see ABB's High Voltage Process
available from ABB at request.
Performance Motors Manual.

Frame 3600 1800 1200 900 720 600


size Ambient C r/min r/min r/min r/min r/min r/min

Ball bearings, horizontal motor: lubrication intervals in duty hours


506AT 25 1500 5100 8800 - - -
2
506AT 40 1000 3000 4400 - - -
587 25 1500 4400 7300 - - -
587 40 1000 2200 3600 - - -
688 25 1250 3000 6600 6600 6600 6600
688 40 750 1500 3000 3000 3000 3000

Frame 3600 1800 1200 900 720 600


size Ambient C r/min r/min r/min r/min r/min r/min

Roller bearings: lubrication intervals in duty hours


506AT 25 - 3000 8000 - - -
506AT 40 - 1500 4400 - - -
587 25 - 1500 5900 - - -
587 40 - 750 3000 - - -
688 25 - 1500 5100 5100 5100 5100
688 40 - 750 2200 2200 2200 2200
Note! Special grease for roller bearings.

ABB /Cat. BU/NEMA GB 10-2004 29


Permissible radial forces
Length of Ball bearings Roller bearings
shaft SI units Imperial units SI units Imperial units
Motor extension 40,000 hours 40,000 hours
size Poles E (mm) FX0 (N) FXmax(N) FX0 (lbs) FXmax(lbs) FX0 (N) FXmax(N) FX0 (lbf) FXmax(lbf)

506 2 140 4600 4100 1034 922 - - - -


4 170 7550 6550 1697 1472 24600 9500 5530 2136
6 170 8450 7300 1900 1641 27600 9500 6205 2136
587 2 140 2050 1850 461 416 - - - -
4 210 9200 7950 2068 1787 33300 12000 7486 2698
6 210 10700 9250 2405 2079 37750 12000 8487 2698
688 2 170 300 250 67 56 - - - -
4 210 7700 6650 1731 1495 38100 15000 8565 3372
6 210 9500 8250 2136 1855 42300 15000 9509 3372
8 210 9500 8250 2136 1855 42300 15000 9509 3372
10 210 9500 8250 2136 1855 42300 15000 9509 3372
12 210 9500 8250 2136 1855 42300 15000 9509 3372

Permissible axial forces


The following tables give the permissible axial forces in Given axial forces FAD, assumes D-bearing locked by
Newton, assuming zero radial force. The values are means of locking ring.
based on normal conditions at 60 Hz with standard
bearings and calculated bearing lives L10h 40,000 hours.

Mounting arrangement IM B3

2 FAD ! #FAZ

SI units 40,000 hours


2-pole 4-pole 6-pole 8-pole 10-pole 12-pole
Motor FAD FAZ FAD FAZ FAD FAZ FAD FAZ FAD FAZ FAD FAZ
size N N N N N N N N N N N N
506 1850 3850 3800 5800 4600 6600 - - - - - -
587 750 4550 3800 7600 5000 8800 - - - - - -
688 100 5100 2650 8650 3450 9450 3450 9450 3450 9450 3450 9450

Imperial units 40,000 hours


2-pole 4-pole 6-pole 8-pole 10-pole 12-pole
Motor FAD FAZ FAD FAZ FAD FAZ FAD FAZ FAD FAZ FAD FAZ
size lbf lbf lbf lbf lbf lbf lbf lbf lbf lbf lbf lbf
506 416 866 854 1304 1034 1484 - - - - - -
587 169 1023 854 1709 1124 1978 - - - - - -
688 22 1147 596 1945 776 2124 776 2124 776 2124 776 2124

Vibration limits
The following table lists the vibration values according to
IEC 60034-14 that the machines fulfil.

Poles Speed Design Bearing housing


rpm vibration

2 1800 < n 3600 Standard 0.1 in./s peak (2.54 mm/s)

4 1800 Standard 0.1 in./s peak (2.54 mm/s)

30 ABB /Cat. BU/NEMA GB 10-2004


Ordering information
Sample order
Motor type M3BM 587 LKA
When placing an order, please state the following Pole number 2
minimum data in the order, as in example. Mounting arrangement (IM code) IM B3 (IM 1001)
The product code of the motor is composed in Rated output 250 HP
accordance with the following example. Product code 3GBM981810-APA
Variant codes if needed

Motor size
A Motor type
A B C D, E, F, G B Motor size
C Product code
M3BM 587LKA 3GBM 981 810 - A P A 003 etc. D Mounting arrangement code
E Voltage and frequency code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 F Generation code
G Variant codes
Explanation of the product code:
Positions 1 to 4 Position 11
3GBM, 3GGM = Totally enclosed fan cooled squirrel cage motor with - (dash)
cast iron frame, high voltage Position 12
Mounting arrangement
Positions 5 and 6 A = Horizontal
NEMA-frame
90 = 50_ Position 13
98 = 58_ Voltage and frequency code
99 = 68_ See table below

Position 7 Position 14
Speed (Pole pairs) Generation code
1 = 2 poles
2 = 4 poles
3 = 6 poles
A, B, C...
The product code must be, if needed, followed by variant
codes.
2
Position 8 to 10
Serial number

Code letters for supplementing the product code - single speed motors

Code letter for voltage and frequency

P W
60 Hz 60 Hz
2300 V 4000 V

ABB /Cat. BU/NEMA GB 10-2004 31


NEMA HV Cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 TEFC / IC 411 Insulation class F, temperature rise class B, S.F. 1.15
Efficiency Power factor Current
Full 3/4 Full 3/4 FLA LRA NLC
1) 1)
Output Motor type Product code Speed load load load load
HP r/min r/min 100% 75% 100% 75% A % Code A

2300 V 60 Hz
125 3600 M3BM 506AT LKA 3GBM 901 810-PA 3577 92.2 91.4 0.91 0.91 28 630 F 5
125 1800 M3BM 506AT LKA 3GBM 902 810-PA 1786 92.6 92.1 0.87 0.86 29 570 F 8
125 1200 M3BM 506AT LKA 3GBM 903 810-PA 1189 93.5 93.3 0.79 0.74 32 570 G 14
125 720 M3BM 688 LA 3GBM 995 510-PA 715 92.8 92.0 0.69 0.63 36 510 G 21
125 600 M3BM 688 LA 3GBM 996 510-PA 595 92.3 91.5 0.64 0.57 40 470 G 24
150 3600 M3BM 506AT LKB 3GBM 901 820-PA 3575 92.7 92.1 0.91 0.91 33 630 F 6
150 1800 M3BM 506AT LKB 3GBM 902 820-PA 1785 93.1 92.7 0.87 0.86 35 580 F 9
150 1200 M3BM 506AT LKB 3GBM 903 820-PA 1186 93.7 93.8 0.80 0.77 37 510 F 14
150 720 M3BM 688 LB 3GBM 995 520-PA 715 93.0 92.3 0.69 0.62 44 520 G 25
150 600 M3BM 688 LB 3GBM 996 520-PA 595 92.7 92.0 0.65 0.59 47 460 G 28
200 3600 M3BM 506AT LKC 3GBM 901 830-PA 3574 93.6 93.2 0.92 0.92 44 640 F 8
200 1800 M3BM 506AT LKC 3GBM 902 830-PA 1785 93.6 93.5 0.87 0.85 46 580 F 13
200 1200 M3BM 506AT LKC 3GBM 903 830-PA 1188 94.5 94.4 0.80 0.76 50 590 G 21
200 900 M3BM 688 LA 3GBM 994 510-PA 894 94.2 93.9 0.77 0.72 52 620 H 25
200 720 M3BM 688 LC 3GBM 995 530-PA 714 93.5 92.9 0.70 0.64 57 510 G 31
200 600 M3BM 688 LC 3GBM 996 530-PA 594 92.9 92.3 0.65 0.59 62 460 G 36
250 3600 M3BM 587 LKA 3GBM 981 810-PA 3580 93.8 93.3 0.90 0.89 56 650 G 13
250 1800 M3BM 506AT LKD 3GBM 902 840-PA 1784 94.3 94.2 0.87 0.86 57 600 F 15
250 1200 M3BM 587 LKA 3GBM 983 810-PA 1191 94.8 94.6 0.78 0.73 64 560 G 28
250 900 M3BM 688 LB 3GBM 994 520-PA 893 94.4 94.2 0.78 0.73 64 580 G 29

2
250 720 M3BM 688 LD 3GBM 995 540-PA 714 93.8 93.3 0.71 0.65 70 500 F 37
250 600 M3BM 688 LD 3GBM 996 540-PA 595 93.1 92.4 0.64 0.57 79 490 G 48
300 3600 M3BM 587 LKB 3GBM 981 820-PA 3579 94.4 94.0 0.90 0.90 66 640 G 13
300 1800 M3BM 587 LKA 3GBM 982 810-PA 1789 94.2 93.9 0.82 0.79 72 570 F 27
300 1200 M3BM 587 LKB 3GBM 983 820-PA 1191 95.0 94.9 0.78 0.74 76 560 G 33
300 900 M3BM 688 LC 3GBM 994 530-PA 893 94.7 94.7 0.79 0.75 75 570 G 31
300 720 M3BM 688 LE 3GBM 995 550-PA 714 93.9 93.4 0.71 0.65 85 530 G 46
350 3600 M3BM 587 LKC 3GBM 981 830-PA 3578 94.7 94.4 0.91 0.91 76 650 G 15
350 1800 M3BM 587 LKB 3GBM 982 820-PA 1789 94.6 94.4 0.83 0.80 84 590 G 30
350 1200 M3BM 587 LKC 3GBM 983 830-PA 1191 95.3 95.2 0.79 0.75 87 560 F 36
350 900 M3BM 688 LD 3GBM 994 540-PA 892 94.8 94.9 0.80 0.76 87 540 F 34
400 3600 M3BM 587 LKD 3GBM 981 840-PA 3577 94.9 94.8 0.91 0.91 87 630 F 15
400 1800 M3BM 587 LKC 3GBM 982 830-PA 1789 94.9 94.7 0.84 0.81 94 610 G 32
400 1200 M3BM 587 LKD 3GBM 983 840-PA 1191 95.4 95.4 0.79 0.75 99 590 G 42
400 900 M3BM 688 LE 3GBM 994 550-PA 893 95.1 95.1 0.80 0.76 99 600 G 41
450 3600 5) M3BM 688 LA 3GBM 991 510-PA 3580 94.7 94.4 0.90 0.89 99 640 G 22
450 1800 M3BM 587 LKD 3GBM 982 840-PA 1789 95.1 94.9 0.84 0.81 106 640 G 38
450 1200 M3BM 587 LKE 3GBM 983 850-PA 1192 95.7 95.6 0.78 0.73 113 610 G 51
500 3600 5) M3BM 688 LB 3GBM 991 520-PA 3578 95.0 94.7 0.90 0.90 109 640 F 22
500 1800 M3BM 587 LKE 3GBM 982 850-PA 1790 95.4 95.3 0.86 0.84 115 640 G 35
500 1200 M3BM 688 LA 3GBM 993 510-PA 1193 95.7 95.7 0.82 0.79 120 620 G 44
550 3600 5) M3BM 688 LC 3GBM 991 530-PA 3578 95.2 95.0 0.91 0.91 119 650 F 23
600 1800 M3BM 688 LA 3GBM 992 510-PA 1789 95.9 95.8 0.86 0.84 136 640 G 41
600 1200 M3BM 688 LB 3GBM 993 520-PA 1193 95.9 96.0 0.82 0.79 143 640 G 52
1) 3)
Motor type is changed to M3GM and product code to 3GGM... in Starting time with given values of the load inertia from cold condition in
hazardous area motors. succession against quadratic load torque with 90% of the rated torque
2)
3600 r/min: The given values of load inertia assume two starts at the rated speed and at rated voltage.
from cold and one start from warm conditions in successions 4)
The sound pressure levels are presented at no-load. The magnetic noise
against quadratic load torque with 90% of the rated torque at the level of 2- and 4-pole machines is typically low compared to the fan
rated speed and at 80% of the rated voltage. noise, resulting no increase in the noise level on-load. Sound level
1800 and 1200 r/min: The given values of load inertia assume values of 6...12-pole machines at on-load are typically 1...3 dB(A) higher
three starts from cold and two starts from warm conditions in than the corresponding values at no-load. The variation and measuring
successions against quadratic load torque with 90% of the rated tolerance of the figures is +3 dB(A).
torque at the rated speed and at 80% of the rated voltage. 5)
Unidirectional fan construction as standard. Direction of rotation must be
Motors fulfil the starting requirements in NEMA MG 1, Part 20. stated when ordering, see variant codes 044 and 045.

The bullet in the product code indicates choice of mounting


arrangement (see ordering information page).
32 ABB /Cat. BU/NEMA GB 10-2004
NEMA HV Cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 TEFC / IC 411 Insulation class F, temperature rise class B, S.F. 1.15
Torque Power Load Starting Maximum Sound
Rated LRT BDT factor inertia time stalling Rotor Rotor Motor pressure
1)
Output Motor type at start 2) cold 3) time hot inertia weight weight levelP4)
HP r/min lb-ft % % cos k lb-ft2 s s lb-ft2 lbs lbs dB(A)

2300 V 60 Hz
125 3600 M3BM 506AT LKA 183 100 240 0.138 113 10 20 41.6 450 2770 83
125 1800 M3BM 506AT LKA 368 140 210 0.19 542 8 20 65.1 530 2740 78
125 1200 M3BM 506AT LKA 552 150 220 0.197 1452 8 20 65.1 540 2710 70
125 720 M3BM 688 LA 919 100 230 0.13 5010 12 24 299 1280 5370 80
125 600 M3BM 688 LA 1103 110 230 0.12 7787 13 26 342 1390 5620 80
150 3600 M3BM 506AT LKB 220 100 240 0.14 133 10 20 41.6 450 2770 83
150 1800 M3BM 506AT LKB 441 140 210 0.19 640 8 20 65.1 530 2740 78
150 1200 M3BM 506AT LKB 664 140 190 0.198 1718 9 20 75.9 590 2860 70
150 720 M3BM 688 LB 1102 110 240 0.13 5935 11 24 299 1280 5370 80
150 600 M3BM 688 LB 1325 100 220 0.12 9830 13 26 385 1500 5880 80
200 3600 M3BM 506AT LKC 294 100 240 0.139 172 9 16 48.5 490 2930 83
200 1800 M3BM 506AT LKC 589 140 200 0.189 831 8 16 65.1 530 2730 78
200 1200 M3BM 506AT LKC 885 170 220 0.196 2237 7 20 108 760 3330 70
200 900 M3BM 688 LA 1175 110 260 0.13 4507 9 20 299 1270 5380 80
200 720 M3BM 688 LC 1471 100 230 0.13 7749 11 24 385 1500 5910 80
200 600 M3BM 688 LC 1768 110 210 0.12 12060 12 26 449 1670 6250 80
250 3600 M3BM 587 LKA 367 90 250 0.119 210 10 20 65.1 610 4040 88
250 1800 M3BM 506AT LKD 736 150 210 0.191 1016 7 14 86.7 630 3040 78
250 1200 M3BM 587 LKA 1103 140 210 0.168 2743 9 20 133 840 4190 76
250 900 M3BM 688 LB 1471 110 240 0.13 5533 10 20 299 1270 5380 80

2
250 720 M3BM 688 LD 1841 100 210 0.13 9523 12 24 427 1610 6170 80
250 600 M3BM 688 LD 2209 120 230 0.12 14829 11 26 577 2000 7040 80
300 3600 M3BM 587 LKB 440 100 240 0.122 246 9 18 81.3 680 4360 88
300 1800 M3BM 587 LKA 881 100 210 0.133 1197 9 18 114 750 4010 80
300 1200 M3BM 587 LKB 1323 140 200 0.168 3238 9 20 153 910 4400 76
300 900 M3BM 688 LC 1766 100 230 0.13 6539 10 20 385 1490 5900 80
300 720 M3BM 688 LE 2208 110 230 0.13 11262 10 24 556 1940 6930 80
350 3600 M3BM 587 LKC 541 90 240 0.111 281 9 15 86.7 700 4440 88
350 1800 M3BM 587 LKB 1028 100 210 0.134 1373 9 18 133 810 4210 80
350 1200 M3BM 587 LKC 1544 140 200 0.169 3722 8 20 191 1050 4810 76
350 900 M3BM 688 LD 2062 100 220 0.13 7526 10 20 427 1600 6170 80
400 3600 M3BM 587 LKD 588 90 230 0.111 315 9 14 97.6 750 4640 88
400 1800 M3BM 587 LKC 1175 110 210 0.135 1545 8 16 153 880 4430 80
400 1200 M3BM 587 LKD 1764 150 210 0.169 4197 8 20 229 1200 5210 76
400 900 M3BM 688 LE 2355 120 240 0.13 8497 9 20 556 1930 6960 80
5)
450 3600 M3BM 688 LA 660 80 250 0.11 443 10 20 133 950 5490 83
450 1800 M3BM 587 LKD 1321 120 220 0.14 1714 7 14 172 950 4600 80
450 1200 M3BM 587 LKE 1983 160 220 0.169 4665 7 20 267 1320 5630 76
5)
500 3600 M3BM 688 LB 734 90 240 0.11 443 9 17 143 980 5650 83
500 1800 M3BM 587 LKE 1468 130 220 0.142 1879 8 15 229 1150 5220 80
500 1200 M3BM 688 LA 2202 140 210 0.152 5125 8 17 470 1660 6350 80
5)
550 3600 M3BM 688 LC 808 100 250 0.117 445 9 17 172 1080 6060 83
600 1800 M3BM 688 LA 1762 140 230 0.144 2201 7 14 370 1570 7060 80
600 1200 M3BM 688 LB 2643 150 210 0.151 6025 8 17 620 2020 7280 80

ABB /Cat. BU/NEMA GB 10-2004 33


NEMA HV Cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 TEFC / IC 411 Insulation class F, temperature rise class B, S.F. 1.15
Efficiency Power factor Current
Full 3/4 Full 3/4 FLA LRA NLC
1) 1)
Output Motor type Product code Speed load load load load
HP r/min r/min 100% 75% 100% 75% A % Code A

4000 V 60 Hz
125 600 M3BM 688 LA 3GBM 996 510-WA 595 91.7 90.9 0.64 0.57 23 480 G 14
150 1200 M3BM 506AT LKA 3GBM 903 810-WA 1191 93.9 93.6 0.78 0.73 22 660 H 10
150 900 M3BM 688 LA 3GBM 994 510-WA 893 93.6 93.2 0.76 0.70 23 540 G 11
150 600 M3BM 688 LB 3GBM 996 520-WA 595 92.2 91.5 0.65 0.58 27 470 G 16
200 1800 M3BM 506AT LKA 3GBM 902 810-WA 1788 94.0 93.7 0.84 0.81 27 650 G 10
200 1200 M3BM 506AT LKB 3GBM 903 820-WA 1189 94.1 94.1 0.79 0.75 29 600 G 12
200 900 M3BM 688 LB 3GBM 994 520-WA 892 94.0 93.7 0.76 0.70 30 550 G 15
200 720 M3BM 688 LA 3GBM 995 510-WA 715 93.1 92.4 0.69 0.62 33 550 H 19
200 600 M3BM 688 LC 3GBM 996 530-WA 594 92.5 92.0 0.65 0.59 36 460 G 21
250 3600 M3BM 587 LKA 3GBM 981 810-WA 3579 93.6 93.1 0.90 0.89 32 640 G 7
250 1800 M3BM 506AT LKB 3GBM 902 820-WA 1786 94.3 94.2 0.84 0.81 34 610 G 12
250 1200 M3BM 587 LKA 3GBM 983 810-WA 1191 94.6 94.4 0.78 0.73 37 560 G 16
250 900 M3BM 688 LC 3GBM 994 530-WA 892 94.1 93.8 0.75 0.69 38 570 G 19
250 720 M3BM 688 LB 3GBM 995 520-WA 714 93.4 93.0 0.71 0.65 41 510 G 22
300 3600 M3BM 587 LKB 3GBM 981 820-WA 3580 94.2 93.8 0.90 0.90 38 650 G 8
300 1800 M3BM 587 LKA 3GBM 982 810-WA 1790 94.0 93.7 0.82 0.78 42 600 G 17
300 1200 M3BM 587 LKB 3GBM 983 820-WA 1192 94.9 94.8 0.78 0.74 44 590 G 19
300 900 M3BM 688 LD 3GBM 994 540-WA 891 94.3 94.2 0.77 0.72 45 530 F 20
300 720 M3BM 688 LC 3GBM 995 530-WA 714 93.7 93.0 0.69 0.62 50 560 H 29

2 350
350
350
3600
1800
1200
M3BM
M3BM
M3BM
587 LKC
587 LKB
587 LKC
3GBM
3GBM
3GBM
981
982
983
830-WA
820-WA
830-WA
3579
1789
1191
94.5
94.3
95.1
94.3
94.1
95.0
0.91
0.83
0.79
0.90
0.80
0.75
44
48
50
650
600
560
G
G
G
9
18
21
350 900 M3BM 688 LE 3GBM 994 550-WA 891 94.7 94.6 0.77 0.72 52 560 G 24
5)
400 3600 M3BM 688 LA 3GBM 991 510-WA 3581 94.3 93.9 0.89 0.88 51 650 G 12
400 1800 M3BM 587 LKC 3GBM 982 830-WA 1790 94.7 94.5 0.83 0.79 55 650 G 21
400 1200 M3BM 587 LKD 3GBM 983 840-WA 1192 95.3 95.2 0.79 0.75 57 610 G 25
5)
450 3600 M3BM 688 LB 3GBM 991 520-WA 3580 94.7 94.4 0.90 0.90 57 650 G 12
450 1800 M3BM 587 LKD 3GBM 982 840-WA 1789 95.0 94.9 0.85 0.83 60 620 G 19
450 1200 M3BM 688 LA 3GBM 993 510-WA 1192 95.5 95.3 0.79 0.75 64 610 G 27
5)
500 3600 M3BM 688 LC 3GBM 991 530-WA 3579 94.8 94.6 0.91 0.90 63 650 G 13
500 1800 M3BM 587 LKE 3GBM 982 850-WA 1790 95.2 95.1 0.86 0.84 66 650 G 20
500 1200 M3BM 688 LB 3GBM 993 520-WA 1192 95.7 95.6 0.80 0.77 70 600 G 28
5)
550 3600 M3BM 688 LD 3GBM 991 540-WA 3579 95.1 95.0 0.91 0.91 68 650 F 13
600 1800 M3BM 688 LA 3GBM 992 510-WA 1790 95.8 95.8 0.86 0.84 79 650 G 24
3)
1)
Motor type is changed to M3GM and product code to 3GGM... in Starting time with given values of the load inertia from cold condition in
hazardous area motors. succession against quadratic load torque with 90% of the rated torque
2)
at the rated speed and at rated voltage.
3600 r/min: The given values of load inertia assume two starts
from cold and one start from warm conditions in successions 4)
The sound pressure levels are presented at no-load. The magnetic
against quadratic load torque with 90% of the rated torque at the noise level of 2- and 4-pole machines is typically low compared to
rated speed and at 80% of the rated voltage. the fan noise, resulting no increase in the noise level on-load. Sound
Motors fulfil the starting requirements in NEMA MG 1, Part 20. level values of 6...12-pole machines at on-load are typically 1...3 dB(A)
higher than the corresponding values at no-load. The variation and
1800 and 1200 r/min: The given values of load inertia assume measuring tolerance of the figures is +3 dB(A).
three starts from cold and two starts from warm conditions in
successions against quadratic load torque with 90% of the rated 5)
Unidirectional fan construction as standard. Direction of rotation must
torque at the rated speed and at 80% of the rated voltage.
be stated when ordering, see variant codes 044 and 045.

The bullet in the product code indicates choice of


mounting arrangement (see ordering information page).

34 ABB /Cat. BU/NEMA GB 10-2004


NEMA HV Cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 TEFC / IC 411 Insulation class F, temperature rise class B, S.F. 1.15
Torque Power Load Starting Maximum Sound
Rated LRT BDT factor inertia time stalling Rotor Rotor Motor pressure
1)
Output Motor type at start 2) cold 3) time hot inertia weight weight levelP4)
HP r/min lb-ft % % cos k lb-ft2 s s lb-ft2 lbs lbs dB(A)

4000 V 60 Hz
125 600 M3BM 688 LA 1103 110 230 0.12 7787 12 26 363 1450 5640 80
150 1200 M3BM 506AT LKA 662 190 250 0.211 1718 7 20 108 750 3250 70
150 900 M3BM 688 LA 883 100 240 0.13 3455 11 22 228 1200 5600 80
150 600 M3BM 688 LB 1325 110 220 0.13 9230 13 26 427 1610 6030 80
200 1800 M3BM 506AT LKA 588 170 240 0.203 831 7 20 62.3 570 3140 78
200 1200 M3BM 506AT LKB 884 170 220 0.209 2237 7 20 108 750 3250 70
200 900 M3BM 688 LB 1177 110 240 0.13 4507 10 22 242 1240 5740 80
200 720 M3BM 688 LA 1470 110 250 0.14 7749 10 24 406 1550 5930 80
200 600 M3BM 688 LC 1768 110 210 0.13 12060 12 26 470 1720 6300 80
250 3600 M3BM 587 LKA 367 90 250 0.128 210 10 20 65.1 610 3960 88
250 1800 M3BM 506AT LKB 735 160 220 0.202 1016 7 20 62.3 570 3150 78
250 1200 M3BM 587 LKA 1103 140 210 0.175 2743 9 20 133 840 4140 76
250 900 M3BM 688 LC 1472 110 250 0.14 5533 9 22 256 1290 5820 80
250 720 M3BM 688 LB 1840 100 220 0.14 9523 11 24 427 1610 6060 80
300 3600 M3BM 587 LKB 440 100 250 0.132 246 9 18 81.3 680 4270 88
300 1800 M3BM 587 LKA 881 110 220 0.147 1197 9 18 114 750 3950 80
300 1200 M3BM 587 LKB 1323 150 210 0.175 3238 8 20 172 980 4530 76
300 900 M3BM 688 LD 1769 100 230 0.14 6539 10 22 299 1420 6220 80
300 720 M3BM 688 LC 2206 120 250 0.13 11262 9 24 577 1990 6980 80
350
350
350
3600
1800
1200
M3BM
M3BM
M3BM
587 LKC
587 LKB
587 LKC
514
1028
1544
100
110
140
250
210
200
0.132
0.147
0.175
281
1373
3722
9
8
8
15
16
20
86.7
133
191
700
820
1050
4380
4130
4730
88
80
76
2
350 900 M3BM 688 LE 2063 110 240 0.13 7526 10 22 370 1630 6920 80
5)
400 3600 M3BM 688 LA 587 80 250 0.111 315 10 20 114 880 5170 83
400 1800 M3BM 587 LKC 1174 130 230 0.146 1545 7 14 153 880 4350 80
400 1200 M3BM 587 LKD 1764 160 220 0.174 4197 7 20 248 1270 5340 76
5)
450 3600 M3BM 688 LB 660 90 250 0.118 349 10 20 143 980 5570 83
450 1800 M3BM 587 LKD 1322 120 210 0.143 1714 8 16 191 1010 4740 80
450 1200 M3BM 688 LA 1983 140 210 0.149 4665 8 20 313 1420 6340 80
5)
500 3600 M3BM 688 LC 734 90 240 0.119 381 9 17 153 1010 5650 83
500 1800 M3BM 587 LKE 1468 130 220 0.15 1879 8 16 248 1210 5300 80
500 1200 M3BM 688 LB 2204 140 210 0.149 5125 8 20 398 1670 7150 80
5)
550 3600 M3BM 688 LD 808 90 230 0.111 412 9 15 172 1070 5960 83
600 1800 M3BM 688 LA 1761 140 220 0.144 2201 7 14 370 1540 6900 80

ABB /Cat. BU/NEMA GB 10-2004 35


NEMA HV Cast iron motors - Variant codes
Code Variant Motor size
1)
506AT 587 688

Balancing
423 Balanced without key P P P
424 Full key balancing. P P P
Bearings and lubrication
036 Transport lock for bearings. P P P
037 Roller bearing at D-end. P P P
107 Bearing mounted PT100 resistance elements. P P P
796 Grease nipples JIS B 1575 PT 1/8 Type A. P P P
Branch standard designs
178 Stainless steel/acid proof bolts. P P P
398 Motor designed for ambient temperature -20C to -40C P P P
Cooling system
044 Unidirectional fan, clockwise seen from D-end. NA NA P
045 Unidirectional fan, counter clockwise seen from D-end. NA NA P
068 Metal fan. P P P
791 Stainless steel fan cover. R R R
Drain holes
065 Plugged existing drain holes. P P P
448 Draining holes with metal plugs. P P P
Hazardous environments
Motor type M3GM.

2
807 CSA design, Class I, Div 2 Group A, B, C, D T3 P P P
809 CSA design, Class I, Zone 2 Ex nA IIC T3 P P P
810 CSA design, Class II, Div 2 Group F, G and Class III P P P
Heating elements
450 Heating element, 100-120 V. P P P
451 Heating element, 200-240 V. P P P
Painting
114 Special paint colour, standard grade. P P P
751 Paint system 2, UV-light. P P P
Surface treatment acc. to the ISO 12944, category 3 with direct UV radiation.
752 Paint system 4, offshore. P P P
Surface treatment acc. to the ISO 12944, category C5 & Norsok M-501.
Protection
158 Degree of protection IP 65. P P P
403 Degree of protection IP 56. P P P
Rating & instruction plates
002 Restamping output, continuous duty. P P P
Standards and regulations
010 Fulfilling CSA Safety Certificate. S S S
Terminal box
021 Terminal box LHS (seen from D-end). P P P
447 Top mounted separate auxiliary box for heating elements. P P P
Testing
146 Type test with report for motor from specific delivery patch. P P P
147 Type test with report for motor from specific delivery patch, customer witnessed. P P P
1)
Certain variant codes cannot be used simultaneously. P = New manufacture only. NA = Not applicable.
R = On request. S = Included as standard.
36 ABB /Cat. BU/NEMA GB 10-2004
NEMA HV Cast iron motors Sizes 506AT-688
Dimension drawings
Type I

2
Motor Poles 2E 2F 2F' 2F'' BA U N-W F! D FP O C A B J
size
506AT 2 20 20 22 28 8.5 2.5 5.5 0.625 12.5 47.9 38.2 58.7 23.2 33.5 3.2
506AT 4-6 20 20 22 28 8.5 3.5 6.5 0.875* 12.5 47.9 38.2 59.7 23.2 33.5 3.2
587 2 23 25 28 36 10 2.75 5.5 0.625 14.5 53.4 41.9 69.4 27.6 42.4 4.7
587 4-6 23 25 28 36 10 4 8.25 1* 14.5 53.4 41.9 72.2 27.6 42.4 4.7
688 2 27 - 32 36 11.5 3.125 6.5 0.75 17 53.4 46.1 72.7 33.1 45.5 5.9
688 4-12 27 - 32 36 11.5 4.375 8.25 1* 17 53.4 46.1 74.4 33.1 45.5 5.9

Motor Poles G P K H R AB OE BSX FDX CX


size
506AT 2 1.7 25.7 13.2 1.26 2.148 32.7 14.4 14 41.5 4.5
506AT 4-6 1.7 25.7 13.2 1.26 3.007 32.7 14.4 15 42.5 4.5
587 2 2.3 29.4 17.6 1.38 2.402 35.5 18.1 15.7 51.5 5.1
587 4-6 2.3 29.4 17.6 1.38 3.436 35.5 18.1 18.4 54.3 5.1
688 2 3 32.8 15.8 1.38 2.704 35.5 22.2 17.8 53.3 5.9
688 4-12 3 32.8 15.8 1.38 3.817 35.5 22.2 19.6 55 5.9

Tolerances:
U +0 -0.001 F!* +0 -0.003 Above table gives the main dimensions in inches.
F! +0 - 0.0025 D +0 -0.06
For detailed drawings please see our web-pages
'www.abb.com/motors&drives' or contact us.
ABB /Cat. BU/NEMA GB 10-2004 37
NEMA HV Cast iron motors Sizes 506AT-688
Dimension drawings
Type II

2
Motor Poles 2E 2F 2F' 2F'' BA U N-W F! D FP O C A B J
size
506AT 2 20 20 22 28 8.5 2.5 5.5 0.625 12.5 48.8 51.3 58.7 23.2 33.5 3.2
506AT 4-6 20 20 22 28 8.5 3.5 6.5 0.875* 12.5 48.8 51.3 59.7 23.2 33.5 3.2
587 2 23 25 28 36 10 2.75 5.5 0.625 14.5 54.2 55 69.4 27.6 42.4 4.7
587 4-6 23 25 28 36 10 4 8.25 1* 14.5 54.2 55 72.2 27.6 42.4 4.7
688 2 27 - 32 36 11.5 3.125 6.5 0.75 17 54.2 59.1 72.7 33.1 45.5 5.9
688 4-12 27 - 32 36 11.5 4.375 8.25 1* 17 54.2 59.1 74.4 33.1 45.5 5.9

Motor Poles G P K H R AB OE BSX FDX CX


size
506AT 2 1.7 25.7 13.2 1.26 2.148 33.6 11.8 14 41.5 4.5
506AT 4-6 1.7 25.7 13.2 1.26 3.007 33.6 11.8 15 42.5 4.5
587 2 2.3 29.4 17.6 1.38 2.402 36.3 15.4 15.7 51.5 5.1
587 4-6 2.3 29.4 17.6 1.38 3.436 36.3 15.4 18.4 54.3 5.1
688 2 3 32.8 15.8 1.38 2.704 36.3 19.6 17.8 53.3 5.9
688 4-12 3 32.8 15.8 1.38 3.817 36.3 19.6 19.6 55 5.9

Tolerances:
U +0 -0.001 F!* +0 -0.003 Above table gives the main dimensions in inches.
F! +0 - 0.0025 D +0 -0.06
For detailed drawings please see our web-pages
'www.abb.com/motors&drives' or contact us.
38 ABB /Cat. BU/NEMA GB 10-2004
Rating plate

Rating plate, HV motor

Lubrication plate
2

Lubrication plate, HV motor

ABB /Cat. BU/NEMA GB 10-2004 39


NEMA HV cast iron motor construction

Typical exploded view of high voltage cast iron motor

1 Stator frame 17 Valve disc with labyrinth seal, N-end


2 End shield, D-end 18 Bearing, N-end
3 Screws for end shield, D-end 19 Inner bearing cover, N-end
4 End shield, N-end 20 Spring
5 Screws for end shield, N-end 21 Screws for bearing cover, N-end
6 Rotor with shaft 22 Fan
7 Key, D-end 23 Fan cover
8 Main terminal box 24 Screws for fan cover
9 Middle box 25 Rating plate
10 Screws for terminal box cover 26 Lubrication plate
11 Outer bearing cover, D-end 27 Auxiliary terminal box
12 Valve disc with labyrinth seal, D-end 28 Grease nipple, D-end
13 Bearing, D-end 29 Grease nipple, N-end
14 Inner bearing cover 30 SPM nipple, D-end
15 Screws for bearing cover, D-end 31 SPM nipple, N-end
16 Outer bearing cover, N-end

40 ABB /Cat. BU/NEMA GB 10-2004


NEMA HV cast iron motors in brief, basic design
Motor size 506AT 587 688

Stator Material Cast iron EN-GJL-250 EN 1561


Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G
Paint thickness Two-pack epoxy paint, thickness 180 m
Bearing end shields Material Cast iron EN-GJL-200 SFS-EN 1561
Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G
Paint thickness Two-pack epoxy paint, thickness 180 m
Bearings D-end 2 pole 6316-M/C3 6316-M/C3 6317-M/C3
4-12 pole 6319/C3 6322/C3 6324/C3
N-end 2 pole 6316-M/C3 6316-M/C3 6317-M/C3
4-12 pole 6316/C3 6316/C3 6319/C3

Axially-locked Inner bearing cover As standard, locked at D-end


bearings

Bearing seal As standard, labyrinth seal in both ends.


Lubrication Regreasable bearings
Regreasing nipples M10x1 DIN 71412 A
SPM-nipples As standard

Rating and Material Stainless steel, EN 10088, thickness 0.5 mm (0.02 ").
lubrication plate

Terminal box Frame material Structural steel S235JRG2-EN-10025, thickness 3 mm (0.12").


Cover material Structural steel S235JRG2-EN-10025, thickness 3 mm (0.12").
Cover screws material Yellow passivated.

Connections Cable entries Blind gland plate.


Terminals 3 terminals for connection with cable lugs (not included)
Grounding locations on frame and terminal box (in- and outside) 2
Fan Material Glass fibre reinforced plastic, aluminum or polyprophene fan with metal hub.
Direction of rotation / fans (IC411)
- plastic bidirectional
- aluminum birectional
- polyprophene fan unidirectional.
Fan cover Material Steel
Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G
Paint thickness Two-pack epoxy polyester powder, thickness 80 m
Stator winding Material Form wound copper, VPI
Insulation Insulation class F
Winding protection PT100, 6 pieces

Rotor winding Material Pressure die-cast aluminum


Balancing method Half key balancing as standard
Key ways Open key way
Heating elements On request 1x200 W 1x200 W 1x300 W
Drain holes Standard, open on delivery.
Enclosure IP 55, higher protection as option.
Cooling method TEFC / IC 411

ABB /Cat. BU/NEMA GB 10-2004 41


ABB Motors total product offer
ABB offers several comprehensive ranges of AC motors and generators. We manufacture synchronous motors for even
the most demanding applications, and a full range of low and high voltage induction motors. Our in-depth knowledge of
virtually every type of industrial processing ensures we always specify the best solution for your needs.

Low voltage motors and generators


General purpose motors for standard Other applications
applications Motors for hazardous areas
Aluminum motors Marine motors
Steel motors Permanent magnet motors
Cast iron motors High speed motors
Open drip proof motors Wind turbine generators
Brake motors NEMA motors
Single phase motors Water cooled motors
Integral motors Motors for roller table drives
Slip ring motors
Process performance motors for more Wood dryer motors
demanding applications Fan application motors
Aluminum motors
Cast iron motors

High voltage and synchronous motors and generators


High voltage cast iron motors
Induction modular motors
Slip ring motors
Motors for hazardous areas
Synchronous motors and generators
DC motors and generators

42 ABB /Cat. BU/NEMA GB 10-2004


Visit our web site
www.abb.com/motors&drives

Motors & Drives


=> Motors
=> Low Voltage Motors
General purpose motors
Process performance motors
Motors for hazardous areas
Marine motors
=> NEMA motors
Other applications
Permanent magnet motors
Smoke venting motors
Fan application motors
Roller table motors
=> High Voltage Motors
=> NEMA motors

ABB /Cat. BU/NEMA GB 10-2004 43


Printed in Finland, 10-2004/5.000, Waasa Graphics Oy
DriveIT Low Voltage Motors
Manufacturing sites (*) and some of the largest sales companies.

Australia France Korea Switzerland


ABB Industry Pty Ltd ABB Automation ABB Korea Ltd. ABB Schweiz AG
2 Douglas Street Rue du Gnral de Gaulle 7-9fl, Oksan Bldg., 157-33 Normelec
Port Melbourne, Champagne-sur-Seine Sungsung-dong, Kangnam-ku Badenerstrasse 790
Victoria, 3207 FR-77811 Moret-sur-Loing Cedex Seoul Postfach
Tel: +61 (0) 3 9644 4100 Tel: +33 (0) 1 60 746 500 Tel: +82 2 528 2329 CH-8048 Zrich
Fax: +61 (0) 3 9646 9362 Fax: +33 (0) 1 60 746 565 Fax: +82 2 528 2338 Tel: +41 (0) 58 586 0000
Fax: +41 (0) 58 586 0603
Austria Germany Malaysia
ABB AG ABB Automation Products GmbH ABB Malaysia Sdn. Bhd. Taiwan
Wienerbergstrasse 11 B Edisonstrasse 15 Lot 608, Jalan SS 13/1K ABB Ltd.
AT-1810 Wien DE-68623 Lampertheim 47500 Subang Jaya, Selangor 6F, No. 126, Nanking East Road,
Tel: +43 (0) 1 601 090 Tel: +49 (0) 6206 503 503 Tel: +60 3 5628 4888 Section 4i
Fax: +43 (0) 1 601 09 8305 Fax: +49 (0) 6206 503 600 Fax: +60 3 5631 2926 Taipei, 105 Taiwan, R.O.C.
Tel: +886 (0) 2 2577 6090
Belgium Hong Kong Mexico Fax: +886 (0) 2 2577 9467
Asea Brown Boveri S.A.-N.V. ABB (Hong Kong) Ltd. ABB Mxico, S.A. de C.V.
Hoge Wei 27 Tai Po Industrial Estate, Apartado Postal 111 Thailand
BE -1930 Zaventem 3 Dai Hei Street, CP 54000 Tlalnepantla ABB Limited (Thailand)
Tel: +32 (0) 2 718 6311 Tai Po, New Territories, Edo. de Mxico, Mxico 161/1 SG Tower,
Fax: +32 (0) 2 718 6657 Hong Kong Tel: +52 5 328 1400 Soi Mahadlekluang 3,
Tel: +852 2929 3838 Fax: +52 5 390 3720 Rajdamri, Bangkok 10330
Canada Fax: +852 2929 3505 Tel: +66 2 665 1000
ABB Inc., BA Electrical Machines The Netherlands Fax: +66 2 665 1042
10300 Henri-Bourassa Blvd, West, India* ABB B.V.
Saint-Laurent, Quebec ABB Ltd. Dept. LV motors (APP2R) The United Kingdom
Canada H4S 1N6 32, Industrial Area, N.I.T P.O.Box 301 ABB Automation Ltd
Tel: +1 514 832-6583 Faridabad 121 001 NL-3000 AH Rotterdam 9 The Towers, Wilmslow Road
Fax: +1 514 332-0609 Tel: +91 (0) 129 502 3001 Tel: +31 (0) 10 4078 879 Didsbury
Fax: +91 (0) 129 502 3006 Fax: +31 (0) 10 4078 345 Manchester, M20 2AB
China* Tel: +44 (0) 161 445 5555
ABB Shanghai Motors Indonesia Norway Fax: +44 (0) 161 448 1016
Company Limited PT. ABB Sakti Industri ABB AS
8 Guang Xing Rd.,Rong Bei JL. Gajah Tunggal Km.1 P.O.Box 154 Vollebekk USA
Town, Songjiang County, Jatiuwung, Tangerang 15136 NO-0520 Oslo ABB Inc.
Shanghai 201613 Banten, Indonesia Tel: +47 22 872 000 Motors and Generators
Tel: +86 21 5778 0988 Tel: + 62 21 590 9955 Fax: +47 22 872 541 16250 W. Glendale Drive
Fax: +86 21 5778 1364 Fax: + 62 21 590 0115 - 6 New Berlin, WI 53151
Singapore Tel: +1 262 785 3200
Chile Ireland ABB Industry Pte Ltd Fax: +1 262 785 8628
Asea Brown Boveri S.A. Asea Brown Boveri Ltd 2 Ayer Rajah Crescent
P.O.Box 581-3 Components Division Singapore 139935 Venezuela
Santiago Belgard Road Tel: +65 6776 5711 Asea Brown Boveri S.A.
Tel: +56 (0) 2 5447 100 Tallaght, Dublin 24 Fax: +65 6778 0222 P.O.Box 6649
Fax: +56 (0) 2 5447 405 Tel: +353 (0) 1 405 7300 Carmelitas,
Fax: +353 (0) 1 405 7327 Spain* Caracas 1010A
Denmark ABB Automation Products S.A. Di- Tel: +58 (0) 2 238 2422
ABB A/S Italy* vision Motores Fax: +58 (0) 2 239 6383
Automation Technology Electrical ABB SACE SpA P.O.Box 81
Machines LV Motors ES-08200 Sabadell
Petersmindevej 1 Via Della Meccanica, 22 Tel: +34 93 728 8500
DK-5000 Odense C IT-20040 Caponago - MI Fax: +34 93 728 8741
Tel: +45 65 477 070 Tel: +39 02 959 6671
Fax: +45 65 477 713 Fax: +39 02 959 667216 Sweden*
ABB Automation Technologies AB
Finland* Japan LV Motors
ABB Oy ABB K.K. SE-721 70 Vsters
LV Motors 26-1 Cerulean Tower Tel: +46 (0) 21 329 000
P.O.Box 633 Sakuragaoka-cho, Shibuya-ku Fax: +46 (0) 21 329 140
FI-65101 Vaasa Tokyo 150-8512
Tel: +358 (0) 10 22 11 Tel: +81 (0) 3 578 46251
Fax: +358 (0) 10 22 47372 Fax: +81 (0) 3 578 46260
Catalogue BU/NEMA GB 10-2004

http://www.abb.com/motors&drives
http://online.abb.com/motors&drives

Você também pode gostar