Você está na página 1de 243

Centrifugal Fans Issue 2.

5 EN

belt driven
August 2013

1
AMCA

Nicotra Gebhardt S.p.A. (Italy) certifies that


ADH-E fans of the E0, E2, E4, E6 and E7 versions,
from sizes 0160 to 0560,
RDH-E fans of the E0, E2, E4, E6 and E7 versions,
from sizes 0180 to 0560,
ADH and RDH fans of the L, R, K, K1 and K2 versions,
from sizes 0630 to 1000,
AT fans of the S, SC, C and TIC versions,
from sizes 7/7 to 30/28,
shown herein are licensed to bear the AMCA Seal.
Nicotra Gebhardt GmbH (Germany) certifies that
RZR fans of the 11, 12, 15 versions, from sizes 0355 to 1000,
shown herein are licensed to bear the AMCA Seal.
The ratings shown are based on tests and procedures perfor-
med in accordance with AMCA Publication 211 and comply
with the requirements of the AMCA Certified Ratings Program.
Air performance with Installation Type A (with free outlet),
and that of the twin fan versions G2L, G2R, G2K, G2K2,
G2E0, G2E2, G2E4, G2E7, SC2, G2C and G2C-C2, and that
of the triple fan versions G3C and G3C-C2 in any installation
type is not AMCA licensed.

Nicotra Gebhardt stands for:

A Maximised flexibility and mini- A Top product quality and shor- A Energy efficiency through com-
mised design effort for custo- ter delivery times thanks to prehensive system know-how
mers, because all radial fan state-of-the-art production
casings have identical dimen- technology
sions no matter what kind of
impeller geometry

I
The NicotraGebhardt portfolio

A strong provider for many optimal


solutions
When it comes to radial fans, we are the first people you should
talk to. From belt-driven radial fans to plugfans, its all there in our
product portfolio. We offer the largest, most comprehensive range of
products in this area and of course the matching services.

ADH-E / ADH AT RDH-E / RDH RZR

double-inlet double-inlet double-inlet double-inlet


forward-curved inch diameters backward-curved hollow aerofoil
impeller geometry forward-curved impeller impeller geometry impeller geometry
geometry

When everything fits

To us, perfection in our product portfolio means that all product By using an identical design for the connection dimensions of every
series in the area of encased radial fans are attuned to one another fan size in our newly developed series ADH-E and RDH-E and
and are 100% compatible in their dimensions. carefully coordinating our options and accessories.
How did we do it? In this way, we have standardised and harmonised our product
portfolio in all relevant areas.

Well designed, easy to install,


economical
A system that saves space, time, and money in an air handling
unit or any other application: our compact base frame offers
decisive advantages:

A The frame lengths have been optimised and


adjusted for the casing position and motor
installation height to achieve the smallest possible overall height
and length
A Exact, optimised coordination of all components, all the way
through to installation, adjustment and testing
A Suitable for all fans of the series ADH-E0, RDH-E0 and RZR-11 up
to size 0500

The compact base frame from NicotraGebhardt


II
proSELECTA II

Simple and reliable selection


proSELECTAII is a technical selection program that allows you to The result from proSELECTAII is the provision of all the
configure your own individually designed fan. It provides you with technical data for your fan, including sound level data, dimension
the opportunity to choose from the entire range of fan types and specifications and accessories. Apart from that, as a registered
their associated options. user, your purchase prices are provided. Additionally fully
dimensioned drawings in DXF format are available, which can be
downloaded and transferred straight into your CAD system.

So that you can be sure

Models and options that are technically not permissible, are


automatically excluded in proSELECTA II. So there is no chance
that you will configure a wrong device option.

What else is important to you

During the fan selection process, you can choose any of the
standardised ATEX options.

Free registration and many advantages


You can register as a proSELECTA II user with us, which enables us
to offer you faster order processing. What this means for you is:
A The complete configuration of your fan with its associated system
accessories and belt drive layout.
A The possibility to produce fans that operate via a frequency
inverter.
A The option of saving your own fan configuration on our server.
A The opportunity to modify your saved configuration, even over the
phone to your NicotraGebhardt representative.

2
High performance centrifugal fan ADH
double inlet for belt drive A Volume
impeller with forward curved blades of galvanised up to 300,000 m/h
sheet steel A Pressure
up to 2,200 Pa

ADH
High performance centrifugal fan AT
double inlet for belt drive A Volume
impeller with forward curved blades of galvanised up to 65,000 m/h
sheet steel A Pressure
up to 2,500 Pa

AT
High performance centrifugal fan RDH
double inlet for belt drive A Volume
centrifugal impeller with backward inclined blades up to 290,000 m/h
A Pressure
up to 3,500 Pa

RDH
High performance centrifugal fan RZR
double inlet for belt drive A Volume
high performance impeller with backward curved up to 300,000 m/h
hollow section true aerofoil blades A Pressure
up to 3,500 Pa

RZR
Fittings / Accessories
A complete system accessories
A miscellaneous fittings
Accessories

Description
A technical description
A operating limits
Description

3
Working towards perfection

The ADHE and ADH series


By further developing sizes 0160 to 0560 of our successful ADH model range, we
have created a product series which boasts a whole host of improvements. The result
is the ADHE generation, one which will overcome the challenges of any application.

During development, we paid particularly close attention to four factors: air volume
flow, pressure, energy efficiency and noise. These aspects are the key to success:
all of the models are on a par with or superior to their predecessors in terms of these
parameters.

New choice of models


Whether you are looking for single or twin fans, the new ADHE series offers impres-
sive further improvements in terms of functionality and potential uses, whatever the
application.

The ultimate in compatibility


Minimised design effort for you means that:
All accessories and equipment are carefully coordinated and compatible to further
product ranges like RDHE / RDH (backward curved centrifugal fans) and RZR
(hollow-airfoil blade geometry).
The connection dimensions for ADHE (sizes 0160 to 0560) are identical with the
corresponding models from the ADH range.
The models for sizes ADH 0630 to 1000 remain unchanged.
All ADHE models up to size 0500 are compatible with the new compact base
frame a unique feature which makes completing your system ultra simple and
affordable!

Top quality for performance and a long service life!


Alongside an intelligent construction, aspects such as the quality of materials and
workmanship play a crucial role in ensuring a long life cycle. Thats why we have
made the casing of the new ADHE even sturdier by means of a standing seam con-
struction. In addition to this, the way in which the blades are attached to the impeller
has been optimised and the shafts have been galvanised for more effective corrosion
protection further factors which significantly increase the service life of this range.

4
The product range at a glance

The technical specifications of the ADHE and ADH series


The standard series are designed for permanent ventilation at up to +80C resp. +100C. The specifications conform to accuracy class 2 accor-
ding to DIN24166.

ADHE and ADH G2E series ADH and ADH G2 Series


Sizes 0160 up to 0560 Sizes 0630 up to 1000
Scroll of galvanesed sheet steel with standing seam Lap jointed scroll of galvanized sheet steel with Pittsburgh-Seam and
and straight cut off V-cut off
New cylindrical impeller with forward-curved blade geometry Volume up to 300.000 m/h
Galvanised shaft Pressure up to 1.800 Pa
Volume up to 120.000 m/h
Pressure up to 2.200 Pa

The ADHE and ADH range of models:


The right fan for every specification!

Depending on the fan size, the ADHE and ADH series have up to 5 mechanical versions of the single fan and up to 4 additional twin fan options.
In this way, we ensure that we have the perfect model for all requirements and any application.

Version Description Figure

Lap jointed scroll without feet and discharge flange.


ADH E0 / ADH L
Light duty bearing execution with pressed steel housing/strut assemblies.

Lap jointed scroll with rectangular side frame, without discharge flange.
ADH E2 / ADH R
Light duty bearing execution with pressed steel housing/strut assemblies.

Lap jointed scroll with heavy duty reinforced side frames, without discharge flange.
ADH E4 / ADH K
Medium duty bearing execution with cast iron pillow block, mounted on a robust pedestal.

Lap jointed scroll with heavy duty reinforced side frames, without discharge flange.
ADH E6 / ADH K1 Medium-heavy duty bearing execution with cast iron pillow block, mounted on a robust pedes-
tal.

Lap jointed scroll with heavy duty reinforced side frames, without discharge flange.
ADH E7 / ADH K2 Heavy duty bearing execution with single-piece resp. split-type plummer block, mounted on a
robust pedestal.

Version Description Figure

The two single fans ADHE0 or ADHL are fitted together to a robust assembly by means of 3
ADH G2E0 U-channels.
Both impellers are fitted on a common shaft supported by 3 bearings.

The two single fans ADHE2 or ADHR are fitted together to a robust assembly by means of 3
ADH G2E2 / ADH G2R angle bars.
Both impellers are fitted on a common shaft supported by 3 bearings.
The two single fans ADHE4 or ADHK are fitted together to a robust assembly by means of 3
angle bars.
ADH G2E4 / ADH G2K
Both impellers are fitted on a common shaft supported by 3 bearings (sizes 0250/-0630) or the
fans have separated shafts being connected by a elastic coupling (sizes 0710/-1000).
The two single fans ADHE7 or ADHK2 are fitted together to a robust assembly by means of 3
angle bars.
ADH G2E7 / ADH G2K2
Both impellers are fitted on a common shaft supported by 3 bearings (sizes 0250/-0630) or the
fans have separated shafts being connected by a elastic coupling (sizes 0710/-1000).

5
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0160 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 160 mm Impeller weight m 1.1 kg
Number of blades z 36 Density of media r1 1.2 kg/m
Moment of Inertia J 0.006 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N do not use in this area Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to air performance ratings only.
Pa
4500
4000
3500
3000
r
2500
%

48

45
46
3.0
42
36

2000 4.0
2.2

38
kW
1.5

29
1500 1/min W W
1.1
4700 31 31

0.75 28 28
4200
1000
0.55 95 dB
3800 25 25
800
0.37 3400 23 23
600
90
0.25 3000 20 20
500
0.18
400 2600 17 17
85
0.12
300 2200 15 15
0.09
r
P

0.06 80
200 1800 12 12

0.04 1600 11 11
150
75
1400 9 9
A7

100 65
LW
SX

1200 8 8
80 Normal operation area 70
ADH E0

ADH E2
DX

Pb
pF

60
300 400 500 600 800 1000 1500 2000 3000 4000 5000 6000 m/h
Measured in installation B
0.08 0.1 0.2 0.4 0.6 0.8 1 m/s according to ISO5801:
qV
2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

2 3 4 6 8 10 20 40 60 80 100 200 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 3500 2 0 -9 -3 -5 -7 -7 -8 -11 dB 9 8 6 -3 -5 -8 -10 -13 dB
SX 2200 1 -5 -4 -3 -11 -4 -6 -9 -14 dB 9 8 1 -4 -6 -9 -11 -16 dB
SX 1400 -1 -5 -1 -5 -4 -5 -6 -11 -17 dB 10 5 -1 -4 -7 -9 -13 -19 dB
qV opt 3500 2 -4 -10 -4 -5 -7 -6 -7 -12 dB 8 6 4 -3 -5 -8 -10 -12 dB
qV opt 2200 0 -8 -5 -3 -11 -5 -6 -8 -13 dB 7 6 -0 -4 -6 -9 -10 -15 dB
qV opt 1400 -1 -7 -2 -6 -5 -5 -6 -11 -16 dB 7 4 -2 -4 -7 -9 -12 -18 dB
DX 3500 2 -10 -15 -6 -7 -10 -6 -7 -7 dB -2 2 4 -4 -6 -6 -8 -8 dB
DX 2200 1 -14 -8 -6 -13 -7 -6 -6 -9 dB 0 5 -3 -5 -5 -8 -8 -11 dB
DX 1400 0 -11 -5 -8 -8 -6 -6 -7 -11 dB 5 1 -4 -6 -6 -8 -9 -13 dB

6
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0160

Dimensions in mm, subject to change.


ADH E0-0160 5 kg
345 153 141 144
205 290 293

22.5
6

7
6
9
20h7

207

205
173
205
30

310

331
153
130 28

121
205
11 16 2 117.5
235 261 = =
265 180
ADH E2-0160 6.6 kg
345 291 294
20 205 141 144
22.5

10
6
6

9
20h7

205
173
205
30

311

329
180
130 28

96
205
9 12 2 117.5
229 261 180
245 263 28

7
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0180 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 180 mm Impeller weight m 1.5 kg
Number of blades z 40 Density of media r1 1.2 kg/m
Moment of Inertia J 0.010 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N do not use in this area Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to air performance ratings only.
Pa
4500
4000
3500
r
3000

53

50
50
2500 kW

42
4.0

43
3.0
%
35

2000

32
2.2
1/min W W
4400 29 29
1500 1.5
4000 26 26
1.1
3600 24 24
1000
0.75 3300 22 22
800 0.55 95 dB 3000 20 20

600 2700 18 18
0.37

500 2400 16 16
0.25
90
400
0.18 2100 14 14

300
0.12 85 1800 12 12
r
P

0.09
1600 11 11
200
0.06
80 1400 9 9
150
0.04
1200 8 8
A7

65 75
LW

100
70 1000 7 7
SX

80 Normal operation area


ADH E0

ADH E2
DX

Pb
pF

60
300 400 500 600 800 1000 1500 2000 3000 4000 5000 6000 m/h
Measured in installation B
0.1 0.2 0.4 0.6 0.8 1 2 m/s according to ISO5801:
qV
2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

2 3 4 6 8 10 20 40 60 80 100 200 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 3500 3 -9 -7 -2 -5 -9 -7 -7 -10 dB 7 10 5 -1 -5 -5 -8 -11 dB
SX 2400 2 -7 -4 -1 -10 -6 -6 -9 -11 dB 10 8 2 -2 -5 -6 -8 -13 dB
SX 1400 1 -4 1 -7 -6 -5 -6 -9 -14 dB 11 5 0 -4 -4 -7 -10 -16 dB
qV opt 3500 3 -11 -9 -3 -6 -9 -7 -7 -9 dB 4 9 4 -1 -6 -5 -7 -10 dB
qV opt 2400 2 -8 -6 -2 -10 -6 -6 -7 -10 dB 8 6 2 -3 -5 -6 -8 -12 dB
qV opt 1400 1 -6 -1 -8 -6 -5 -6 -9 -14 dB 9 4 -1 -4 -4 -6 -10 -15 dB
DX 3500 2 -19 -15 -8 -10 -10 -6 -6 -6 dB -5 3 1 -4 -7 -4 -6 -8 dB
DX 2400 1 -17 -12 -7 -13 -7 -6 -6 -8 dB -1 3 -4 -5 -6 -4 -7 -10 dB
DX 1400 0 -13 -7 -12 -8 -6 -6 -7 -11 dB 4 -2 -5 -6 -4 -7 -9 -13 dB

8
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0180

Dimensions in mm, subject to change.


ADH E0-0180 6 kg
370 167 154 157
229 319 322

22.5
6

7
6
9
20h7

227

229
195
227
30

344

365
167
130 28

135
229
11 16 2 129.5
259 285 = =
289 180
ADH E2-0180 7.8 kg
370 320 323
20 229 154 157
22.5

8
6

9
20h7

229
195
227
30

346

366
180
130 28

111
229
9 12 2 129.5
253 285 180
269 290 30

9
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0200 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 200 mm Impeller weight m 1.6 kg
Number of blades z 38 Density of media r1 1.2 kg/m
Moment of Inertia J 0.014 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N do not use in this area Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to air performance ratings only.
Pa
4500
4000
r
3500

52
55
3000

53

44
7.5

48
%
2500 kW 5.5
41

33
4.0 1/min W W W
2000 4200 28 28 28
3.0
3800 25 25 25
1500 2.2

3300 22 22 22
1.5

1000 1.1 2900 19 19 19

800 2600 17 17 17
0.75 95 dB

600 0.55 2300 15 15 15

500
0.37 90 2000 13 13 13
400
1800 12 12 12
0.25

300 0.18 1600 11 11 11


85

1400 9 9 9
r
P

0.12
200
0.09
80 1200 8 8 8
150
0.06

1000 7 7 7
A7

65 75
LW

100 70 900 6 6 6
Normal operation area
SX

80
ADH E0

ADH E2

ADH E4
DX

Pb
pF

60
500 600 800 1000 1500 2000 3000 4000 5000 6000 8000 10000 m/h
Measured in installation B
0.2 0.4 0.6 0.8 1 2 3 m/s according to ISO5801:
qV
2 3 4 5 6 7 8 9 10 14 20 30 40 50 m/s
v2

3 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 3300 2 -11 -9 1 -5 -10 -7 -8 -10 dB 5 8 4 -2 -6 -6 -8 -11 dB
SX 2000 2 -8 1 -2 -9 -6 -7 -8 -13 dB 8 6 2 -4 -4 -7 -8 -14 dB
SX 1200 1 -3 3 -6 -6 -5 -6 -10 -16 dB 8 4 -1 -3 -5 -7 -10 -19 dB
qV opt 3300 2 -14 -11 -0 -6 -10 -6 -8 -9 dB 3 5 2 -2 -6 -4 -8 -9 dB
qV opt 2000 2 -11 -0 -3 -9 -6 -7 -7 -12 dB 5 3 1 -5 -3 -7 -7 -13 dB
qV opt 1200 1 -5 1 -7 -6 -5 -6 -9 -15 dB 5 3 -2 -3 -4 -7 -9 -18 dB
DX 3300 3 -19 -15 -6 -8 -11 -6 -6 -7 dB -4 2 0 -3 -7 -3 -5 -7 dB
DX 2000 2 -16 -8 -7 -12 -6 -6 -6 -9 dB -0 2 -2 -6 -3 -5 -6 -9 dB
DX 1200 1 -12 -5 -11 -8 -6 -6 -8 -10 dB 3 -1 -5 -5 -3 -6 -8 -12 dB

10
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0200

Dimensions in mm, subject to change.


ADH E0-0200 7.1 kg
420 189 163 166
256 348 351

22.5
6

6
6
9
20h7

250

256
216
258
30

378

400
186
130 28

144
256
11 16 2 143
286 312 = =
316 224
ADH E2-0200 9.1 kg
420 348 351
25 256 163 166
22.5

8
6

9
20h7

256
216
258
30

379

399
224
130 28

113
256
11 16 2 143
286 312 224
306 312 36
ADH E4-0200 12.6 kg
420 348 351
25 256 163 166
22.5

8
6

9
20h7

256
216
258
30
379

399
224

130 28
113

256
11 16 2 143
286 312 224
306 312 36

11
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0225 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 225 mm Impeller weight m 1.8 kg
Number of blades z 42 Density of media r1 1.2 kg/m
Moment of Inertia J 0.020 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N do not use in this area Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to air performance ratings only.
Pa
4500
4000
r
3500

57
60

49
3000

58
7.5

51

38
2500 %
5.5 3800 25 25 25
42

kW
1/min W W W
2000 4.0
3400 23 23 23
3.0
1500 3000 20 20 20
2.2

2600 17 17 17
1.5
1000

1.1 2300 15 15 15
800 95 dB

0.75 2000 13 13 13
600
0.55 1800 12 12 12
500 90

0.37 1600 11 11 11
400

0.25 1400 9 9 9
300 85
r
P

0.18
1200 8 8 8

200 0.12 80

0.09 1000 7 7 7
65
A7

150 70
LW

75 900 6 6 6

Normal operation area


SX

100
DX

80
ADH E0

ADH E2

ADH E4

Pb
pF

60
600 800 1000 1500 2000 3000 4000 5000 6000 8000 10000 15000 m/h
Measured in installation B
0.2 0.4 0.6 0.8 1 2 3 4 m/s
qV according to ISO5801:

3 4 5 6 7 8 9 10 14 20 30 40 50 m/s
v2

3 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 3000 4 -9 -7 2 -4 -11 -7 -8 -11 dB 6 7 9 -2 -6 -6 -10 -12 dB
SX 1800 2 -7 2 0 -9 -7 -6 -8 -13 dB 8 10 4 -4 -4 -8 -10 -14 dB
SX 1000 1 2 4 -6 -5 -5 -6 -11 -16 dB 12 9 -1 -3 -5 -8 -12 -19 dB
qV opt 3000 3 -12 -10 1 -5 -11 -6 -8 -9 dB 4 5 8 -2 -6 -4 -9 -10 dB
qV opt 1800 2 -10 -0 -1 -9 -6 -7 -7 -12 dB 5 8 3 -4 -3 -7 -8 -12 dB
qV opt 1000 1 -1 2 -7 -5 -5 -6 -10 -15 dB 9 7 -2 -2 -5 -7 -10 -16 dB
DX 3000 3 -16 -14 -7 -6 -11 -6 -7 -7 dB -1 2 2 -3 -6 -3 -5 -7 dB
DX 1800 2 -15 -9 -5 -11 -6 -7 -6 -8 dB 0 3 -1 -5 -3 -5 -6 -9 dB
DX 1000 1 -10 -4 -10 -7 -6 -6 -8 -11 dB 3 1 -4 -4 -4 -5 -8 -12 dB

12
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0225

Dimensions in mm, subject to change.


ADH E0-0225 8.5 kg
450 209 182 185
288 388 391

22.5
6

7
6
9
20h7

279

288
241
287
30

422

443
202
130 28

156
288
11 16 2 159
318 344 = =
348 224
ADH E2-0225 10.7 kg
450 390 393
25 288 182 185
22.5

11
6
6

9
20h7

288
241
287
30

425

442
224
130 28

127
288
11 16 2 159
318 344 224
338 351 39
ADH E4-0225 14.5 kg
450 390 393
25 288 182 185
22.5

11
6
6

9
20h7

288
241
287
30
425

442
224

130 28
127

288
11 16 2 159
318 344 224
338 351 39

13
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0250 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 250 mm Impeller weight m 2.7 kg
Number of blades z 38 Density of media r1 1.2 kg/m
Moment of Inertia J 0.036 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N ADHE4 only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N do not use in this area The AMCA Certified Ratings Seal applies to air performance ratings only.
Pa
4500
4000
r
3500

56
59
3000

48
57
11
%

53
kW
47 7.5

37
2500 1/min W W W
5.5
3200 21 21 38
2000 3000 20 20 36
4.0
2800 19 19 34
3.0
1500
2500 17 17 30
2.2
100 dB 2200 15 15 26
1000 1.5
2000 13 13 24
800 1.1
1800 12 12 22
0.75 95
600
1600 11 11 19
500 0.55

1400 9 9 17
400 0.37 90

1200 8 8 14
300 0.25
r

0.18 85
P

1000 7 7 12
200
0.12 900 6 6 11

150 80
800 5 5 10
65
A7

70
LW

700 5 5 8
100 75
Normal operation area
SX

DX

80
ADH E0

ADH E2

ADH E4

Pb
pF

60
800 1000 1500 2000 3000 4000 5000 6000 8000 10000 15000 m/h
Measured in installation B
0.4 0.6 0.8 1 2 3 4 5 m/s
qV according to ISO5801:

3 4 5 6 7 8 9 10 14 20 30 40 50 m/s
v2

3 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 2000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 2800 2 -7 -6 -1 -5 -11 -5 -8 -10 dB 6 6 2 -3 -6 -4 -10 -11 dB
SX 1600 1 -6 -4 -1 -10 -4 -7 -8 -13 dB 7 3 0 -4 -3 -9 -9 -14 dB
SX 1000 0 -5 2 -7 -5 -5 -7 -10 -15 dB 6 2 -2 -2 -6 -8 -11 -19 dB
qV opt 2800 2 -9 -8 -2 -6 -11 -5 -8 -9 dB 4 3 0 -3 -5 -3 -10 -9 dB
qV opt 1600 1 -8 -6 -3 -10 -4 -8 -8 -12 dB 4 1 -1 -5 -2 -9 -9 -13 dB
qV opt 1000 1 -7 1 -8 -4 -5 -7 -9 -15 dB 4 1 -3 -1 -6 -8 -10 -17 dB
DX 2800 2 -12 -11 -9 -8 -12 -5 -7 -7 dB 0 1 -1 -4 -7 -2 -7 -7 dB
DX 1600 2 -12 -10 -7 -12 -5 -7 -7 -8 dB 1 -0 -4 -7 -2 -6 -7 -9 dB
DX 1000 1 -11 -6 -10 -6 -6 -7 -7 -11 dB 1 -3 -5 -3 -4 -7 -8 -11 dB

14
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0250

Dimensions in mm, subject to change.


ADH E0-0250 10.5 kg
485 232 195 198
322 423 426

22.5
6

7
6
9
20h7

304

322
268
322
30

467

488
215
130 28

161
322
11 16 2 176
352 378 = =
382 224
ADH E2-0250 13 kg
485 425 428
25 322 195 198
22.5

10
6
6

9
20h7

322
268
322
30

470

488
224
130 28

138
322
11 16 2 176
352 378 224
372 386 39
ADH E4-0250 18 kg
515 425 428
25 322 195 198

10
8
28
7

9
25h7

322
268
322
40
470

488
224

130 28
138

322
11 16 2 176
352 378 224
372 386 39

15
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0280 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 280 mm Impeller weight m 3.5 kg
Number of blades z 42 Density of media r1 1.2 kg/m
Moment of Inertia J 0.059 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N ADHE4 only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N do not use in this area The AMCA Certified Ratings Seal applies to air performance ratings only.
Pa
4500
4000
r
3500

56
59

47
3000 15

57
kW 11

51
%
2500 44
7.5 1/min W W W

34
3000 36 36 45
2000 5.5
2700 32 32 41
4.0
1500 2500 30 30 38
3.0

2.2 2100 25 25 32
1000 100 dB

1.5
800 1800 22 22 27
1.1
600 95 1600 19 19 24
0.75
500
1400 17 17 21
0.55
400
90
1200 14 14 18
0.37
300

0.25
1000 12 12 15
85
r
P

200 0.18

150 0.12 800 10 10 12


80

700 8 8 11
65
100 70
A7
LW

75
600 7 7 9
80 Normal operation area
SX

ADH E0

ADH E2

ADH E4
DX

Pb
pF

60
1000 1500 2000 3000 4000 5000 6000 8000 10000 15000 20000 m/h
Measured in installation B
0.4 0.6 0.8 1 2 3 4 5 6 m/s
qV according to ISO5801:

2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

3 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 2500 3 -6 -6 1 -4 -9 -6 -9 -12 dB 5 5 7 -1 -5 -6 -11 -13 dB
SX 1400 2 -4 3 -2 -8 -4 -7 -10 -13 dB 7 9 1 -4 -3 -9 -11 -16 dB
SX 800 0 2 2 -6 -3 -6 -7 -11 -16 dB 11 5 -1 -1 -7 -9 -13 -21 dB
qV opt 2500 3 -10 -10 -1 -6 -10 -5 -9 -11 dB 1 1 5 -2 -5 -4 -10 -12 dB
qV opt 1400 2 -9 0 -4 -9 -4 -7 -9 -13 dB 2 7 -0 -4 -2 -9 -10 -14 dB
qV opt 800 1 -0 -0 -8 -3 -6 -7 -10 -16 dB 7 3 -2 -1 -7 -8 -12 -19 dB
DX 2500 2 -10 -9 -6 -7 -11 -5 -7 -7 dB 3 3 1 -2 -5 -3 -8 -9 dB
DX 1400 1 -9 -6 -6 -11 -5 -7 -7 -10 dB 3 2 -2 -5 -3 -8 -9 -12 dB
DX 800 0 -6 -4 -10 -5 -6 -5 -9 -14 dB 4 -0 -4 -2 -6 -7 -10 -16 dB

16
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0280

Dimensions in mm, subject to change.


ADH E0-0280 14.2 kg
555 261 215 218
361 471 474
8

6
28
7
9
25h7

242

361
302
361
40

524

546
242
130 28

183
361
11 16 2 195.5
391 417 = =
421 280
ADH E2-0280 18 kg
555 472 475
30 361 215 218
8

9
28
7

9
25h7

361
302
361
40

526

545
280
130 28

156
361
13 18 2 195.5
391 417 280
421 435 37
ADH E4-0280 24 kg
580 472 475
30 361 215 218
8

9
33
7

9
30h7

361
302
361
40
526

545
280

130 28
156

361
13 18 2 195.5
391 417 280
421 435 37

17
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0315 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 315 mm Impeller weight m 4.6 kg
Number of blades z 38 Density of media r1 1.2 kg/m
Moment of Inertia J 0.100 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N ADHE4/E6 only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N ADHE6 only The AMCA Certified Ratings Seal applies to air performance ratings only.
Pa N do not use in this area
4500
4000 r
3500 30

59
18.5

63

49
3000 15

60

36
52
2500 11
39
% 2700 32 32 41 135
kW 1/min W W W W
2000
7.5 2400 29 29 36 120

1500 5.5
2100 25 25 32 105
105 dB
4.0 1900 23 23 29 95

1000 3.0
1700 20 20 26 85

800 2.2 100


1500 18 18 23 75
1.5
600
1300 16 16 20 65
500 1.1
95

400 0.75 1100 13 13 17 55

0.55 1000 12 12 15 50
300 90
900 11 11 14 45

800 10 10 12 40
200
0.25
85
r
P

700 8 8 11 35
150

0.12 80 600 7 7 9 30
A7

100 65
LW

70
80 75 500 6 6 8 25
ADH E0

ADH E2

ADH E4

ADH E6

Normal operation area


SX

DX

Pb
pF

60
1500 2000 3000 4000 5000 6000 8000 10000 15000 20000 m/h
Measured in installation B
0.3 0.4 0.6 0.8 1 2 3 4 5 6 7 m/s
qV according to ISO5801:

2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

3 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 2100 4 -1 -1 -3 -6 -7 -6 -9 -11 dB 10 10 3 -1 -2 -5 -9 -8 dB
SX 1300 3 0 -2 -3 -9 -7 -8 -9 -13 dB 11 6 1 -3 -1 -8 -7 -11 dB
SX 700 2 1 -1 -7 -2 -6 -7 -11 -18 dB 9 3 -1 1 -6 -6 -8 -17 dB
qV opt 2100 4 -4 -3 -4 -7 -7 -6 -8 -10 dB 6 6 1 -2 -1 -4 -9 -7 dB
qV opt 1300 3 -3 -4 -4 -9 -4 -8 -9 -13 dB 7 4 -1 -3 -0 -7 -7 -10 dB
qV opt 700 3 -2 -3 -7 -2 -6 -7 -10 -17 dB 6 2 -1 2 -5 -5 -7 -16 dB
DX 2100 3 -5 -5 -7 -9 -8 -6 -7 -8 dB 4 4 -3 -5 -3 -4 -8 -6 dB
DX 1300 2 -5 -7 -7 -12 -5 -7 -7 -10 dB 4 0 -4 -7 -1 -7 -6 -8 dB
DX 700 2 -5 -6 -11 -4 -6 -6 -9 -14 dB 2 -3 -6 -0 -6 -5 -6 -13 dB

18
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0315

Dimensions in mm, subject to change.


ADH E0-0315 18 kg
600 289 236 239
404 522 525
8

7
28
7
9
25h7

376

404
338
403
40

586

607
267
130 28

202
404
11 16 2 217
434 460 = =
464 280
ADH E2-0315 22 kg
600 524 527
30 404 236 239

10
8
28
7

9
25h7

404
338
403
40

588

606
280
130 28

175
404
13 18 2 217
434 460 280
464 486 38
ADH E4-0315 29 kg
625 524 527
30 404 236 239

10
8
33
7

9
30h7

404
338
403
40
588

606
280

130 28
175

404
13 18 2 217
434 460 280
464 486 38
ADH E6-0315 30 kg
625 524 527
30 404 236 239
10

8
33
7

9
30h7
404
338
403

40
588

606
280

130 28
175

404
13 18 2 217
434 460 280
464 486 38

19
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0355 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 355 mm Impeller weight m 5.5 kg
Number of blades z 42 Density of media r1 1.2 kg/m
Moment of Inertia J 0.150 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N ADHE4/E6 only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N ADHE6 only The AMCA Certified Ratings Seal applies to air performance ratings only.
Pa N do not use in this area
4500
4000
r
3500

60
22

65
3000 30

49
62
15 18.5

54
%
2500 11
45

kW

34
1/min W W W W
2000 7.5
2200 33 33 37 136

5.5 2000 30 30 34 124


1500
4.0 1800 27 27 31 112

3.0
1000 1600 24 24 27 99
105 dB
2.2
800 1400 21 21 24 87
1.5
600 100 18 18 20 74
1.1 1200
500 1100 17 17 19 68
0.75
400 1000 15 15 17 62
95
900 14 14 15 56
300
0.37
800 12 12 14 50
r
P

90
200 700 11 11 12 43
0.18
150 600 9 9 10 37
85
65 70
75
A7

100 500 8 8 9 31
80
LW

Normal operation area


80
SX

DX

ADH E0

ADH E2

ADH E4

ADH E6
Pb
pF

60
1500 2000 3000 4000 5000 6000 8000 10000 15000 20000 30000 m/h
Measured in installation B
0.4 0.6 0.8 1 2 3 4 5 6 7 8 10 m/s
qV according to ISO5801:

2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

3 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1800 4 3 2 -1 -6 -6 -7 -9 -12 dB 13 11 3 -1 -2 -7 -9 -10 dB
SX 1200 3 4 0 -2 -6 -5 -7 -10 -14 dB 14 6 3 -2 -3 -8 -8 -13 dB
SX 600 2 3 -0 -4 -3 -5 -7 -12 -19 dB 9 5 1 -1 -6 -5 -11 -18 dB
qV opt 1800 3 -3 -3 -5 -8 -5 -7 -8 -10 dB 6 5 0 -3 -2 -6 -8 -8 dB
qV opt 1200 2 -2 -4 -6 -7 -4 -7 -9 -13 dB 7 2 -1 -2 -2 -8 -7 -12 dB
qV opt 600 2 -2 -4 -6 -3 -5 -7 -11 -17 dB 3 1 -1 -0 -6 -5 -10 -17 dB
DX 1800 2 -8 -8 -9 -11 -6 -7 -6 -7 dB 2 2 -3 -6 -3 -5 -7 -6 dB
DX 1200 2 -8 -10 -9 -10 -5 -7 -6 -10 dB 2 -3 -4 -6 -3 -8 -6 -9 dB
DX 600 1 -9 -9 -10 -5 -6 -5 -9 -14 dB -2 -3 -5 -2 -7 -5 -8 -13 dB

20
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0355

Dimensions in mm, subject to change.


ADH E0-0355 23 kg
675 327 261 264
453 582 585
8

7
33
7
9
30h7

418

453
381
450
40

658

679
281
130 28

212
453
11 16 2 241.5
493 509 = =
533 355
ADH E2-0355 29 kg
675 586 589
40 453 261 264

13
8
33
8

9
30h7

453
381
450
40

665

680
355
130 28

202
453
13 18 2 241.5
493 509 355
533 547 39
ADH E4-0355 41 kg
685 586 589
40 453 261 264

13
10
38
8

9
35h7

453
381
450
50
665

680
355

130 28
202

453
13 18 2 241.5
493 509 355
533 547 39
ADH E6-0355 42 kg
685 586 589
40 453 261 264
13

10
38
8

9
35h7
453
381
450

50
665

680
355

130 28
202

453
13 18 2 241.5
493 509 355
533 547 39

21
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0400 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 400 mm Impeller weight m 9 kg
Number of blades z 38 Density of media r1 1.2 kg/m
Moment of Inertia J 0.310 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N ADHE4/E6 only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N ADHE6 only The AMCA Certified Ratings Seal applies to air performance ratings only.
Pa N do not use in this area
4500
4000
r
3500

61
30

65

51
3000 22

62

39
2500 kW

52
2000 30 30 34 124
15
1/min W W W W
%
38

2000 1800 27 27 31 112


11

1500 1600 24 24 27 99
7.5
105 dB 1400 21 21 24 87
5.5
1000
4.0
1200 18 18 20 74
800
3.0 100

600 2.2 1000 15 15 17 62

500 900 14 14 15 56
1.5
95
400 1.1 800 12 12 14 50

300 0.75 700 11 11 12 43


90

600 9 9 10 37
r
P

200
0.37
85
150 500 8 8 9 31

0.18 80
A7

65 70
100 60
LW

75 400 6 6 7 25

80 Normal operation area


ADH E0

ADH E2

ADH E4

ADH E6
DX
SX

Pb
pF

60
2000 3000 4000 5000 6000 8000 10000 15000 20000 30000 m/h
Measured in installation B
0.6 0.8 1 2 3 4 5 6 7 8 9 10 m/s
qV according to ISO5801:

2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

2 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1600 5 4 3 -3 -7 -5 -8 -8 -11 dB 11 10 5 0 1 -6 -9 -8 dB
SX 1000 4 5 0 -5 -4 -6 -7 -9 -14 dB 12 7 2 3 -3 -7 -7 -12 dB
SX 500 3 2 -3 -2 -4 -5 -7 -12 -19 dB 9 4 5 -1 -5 -5 -10 -20 dB
qV opt 1600 4 -2 -3 -7 -9 -5 -7 -8 -10 dB 5 5 1 -2 1 -5 -8 -7 dB
qV opt 1000 4 -1 -5 -8 -5 -6 -7 -8 -13 dB 6 3 0 2 -3 -7 -6 -11 dB
qV opt 500 2 -3 -6 -3 -4 -5 -6 -11 -17 dB 4 1 4 -1 -5 -4 -9 -18 dB
DX 1600 3 -7 -8 -11 -11 -7 -6 -6 -7 dB 2 1 -3 -6 -1 -4 -7 -6 dB
DX 1000 2 -7 -10 -11 -9 -6 -7 -6 -10 dB 2 -3 -4 -2 -3 -6 -6 -9 dB
DX 500 1 -9 -10 -8 -5 -6 -6 -9 -14 dB -2 -3 -1 -2 -5 -5 -8 -15 dB

22
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0400

Dimensions in mm, subject to change.


ADH E0-0400 31 kg
725 366 290 293
507 654 657
8

7
33
7
9
30h7

469

507
432
507
40

745

766
200

309
130 28

234
507
11 16 537
547 563 = =
587 355
ADH E2-0400 38 kg
725 657 660
40 507 290 293

11
8
33
8

9
30h7

507
432
507
40

750

767
355
200

130 28

232
507
13 18 537
547 563 355
587 614 43
ADH E4-0400 52 kg
750 657 660
40 507 290 293

11
10
38
8

9
35h7

507
432
507
50
750

767
355

200

130 28
232

507
13 18 537
547 563 355
587 614 43
ADH E6-0400 53 kg
750 657 660
40 507 290 293
11

10
38
8

9
35h7
507
432
507

50
750

767
355

200

130 28
232

507
13 18 537
547 563 355
587 614 43

23
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0450 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 450 mm Impeller weight m 11 kg
Number of blades z 42 Density of media r1 1.2 kg/m
Moment of Inertia J 0.480 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N ADHE4/E6 only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N ADHE6 only The AMCA Certified Ratings Seal applies to air performance ratings only.
Pa N do not use in this area
4500
4000
3500
r
3000
30

60
64
2500 37

50
22

61

39
1/min W W W W

52
2000
15
%

1600 27 27 34 128
42

kW 1500 25 25 32 120
11
1500 1400 24 24 29 112

7.5 1300 22 22 27 104


105 dB
1200 20 20 25 96
1000 5.5
1100 19 19 23 88
800 4.0
100 1000 17 17 21 80
3.0
600 900 15 15 19 72
2.2
500
800 14 14 17 64
95
400 1.5
700 12 12 15 56
1.1
300
90
0.75 600 10 10 13 48

200
85 500 8 8 11 40
0.37
r
P

150

80 400 7 7 8 32
A7

100 0.18 65 70
LW

75 350 6 6 7 28
80 Normal operation area
ADH E0

ADH E2

ADH E4

ADH E6
SX

DX

Pb
pF

60
3000 4000 5000 6000 8000 10000 15000 20000 30000 40000 m/h
Measured in installation B
1 2 3 4 5 6 7 8 9 10 14 m/s
qV according to ISO5801:

2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

2 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1400 3 0 1 -4 -8 -4 -8 -9 -12 dB 7 6 2 -1 -1 -7 -10 -10 dB
SX 1000 3 1 0 -6 -5 -4 -8 -10 -14 dB 8 5 2 1 -3 -8 -8 -13 dB
SX 500 2 2 -4 -3 -2 -6 -8 -12 -18 dB 7 4 3 0 -6 -6 -11 -18 dB
qV opt 1400 3 -3 -2 -6 -9 -3 -8 -9 -12 dB 3 3 0 -1 0 -7 -9 -10 dB
qV opt 1000 3 -3 -2 -7 -5 -4 -8 -9 -14 dB 4 2 0 1 -3 -8 -8 -12 dB
qV opt 500 2 0 -5 -3 -2 -6 -7 -12 -17 dB 4 2 3 -1 -6 -6 -10 -18 dB
DX 1400 3 -7 -7 -10 -12 -5 -7 -7 -9 dB 3 2 -2 -5 -2 -5 -7 -7 dB
DX 1000 2 -7 -8 -11 -9 -5 -7 -7 -10 dB 3 0 -3 -3 -2 -6 -7 -9 dB
DX 500 1 -7 -10 -8 -4 -6 -6 -9 -14 dB 1 -2 -2 -2 -5 -6 -8 -14 dB

24
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0450

Dimensions in mm, subject to change.


ADH E0-0450 42 kg
815 415 322 325
569 732 735
10

7
38
8
9
35h7

526

569
487
571
50

838

859
200

344
130 28

260
569
13 18 599
619 625 = =
665 530
ADH E2-0450 50 kg
815 733 736
40 569 322 325

11
10
38
8

9
35h7

569
487
571
50

841

858
530
200

130 28

259
569
13 18 599
619 625 530
649 687 46
ADH E4-0450 66 kg
850 733 736
40 569 322 325

11
12
43
8

9
40h7

569
487
571
70
841

858
530

200

130 28
259

569
13 18 599
619 625 530
649 687 46
ADH E6-0450 67 kg
850 733 736
40 569 322 325
11

12
43
8

9
40h7
569
487
571

70
841

858
530

200

130 28
259

569
13 18 599
619 625 530
649 687 46

25
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0500 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 500 mm Impeller weight m 18 kg
Number of blades z 38 Density of media r1 1.2 kg/m
Moment of Inertia J 0.900 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N ADHE4/E6/E7 only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N ADHE6/E7 only The AMCA Certified Ratings Seal applies to air performance ratings only.
Pa N ADHE7 only
4500 N do not use in this area
4000
3500 r
3000

62
37

65
45

51
2500 30

62

39
1/min W W W W

51
2000 22 1500 25 32 120 188
1400 24 29 112 175
%
35

kW 1300 22 27 104 163


1500
15
1200 20 25 96 150
11
1100 19 23 88 138
1000
7.5 105 dB 1000 17 21 80 125
800
5.5 900 15 19 72 113

600 4.0 800 14 17 64 100


100
500 3.0
700 12 15 56 88
400 2.2
95 600 10 13 48 75
300
1.3

500 8 11 40 63
90
200 0.75
r
P

150 400 7 8 32 50
0.45 85
A7

70 75
LW

65 80 350 6 7 28 44
100
0.25
Normal operation area
ADH E0/E2
DX
SX

80
ADH E4

ADH E6

ADH E7
Pb
pF

60
3000 4000 5000 6000 8000 10000 15000 20000 30000 40000 60000 m/h
Measured in installation B
1 2 3 4 5 6 7 8 9 10 14 m/s
qV according to ISO5801:

2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

2 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1300 3 3 1 -7 -6 -5 -7 -9 -12 dB 7 4 3 -1 -2 -8 -9 -12 dB
SX 800 2 3 -3 -6 -4 -6 -6 -10 -14 dB 7 4 0 1 -6 -8 -9 -16 dB
SX 400 0 -1 -4 -2 -4 -4 -8 -12 -17 dB 6 2 3 -4 -6 -7 -14 -20 dB
qV opt 1300 3 -4 -5 -11 -7 -5 -7 -8 -10 dB 1 -1 -1 -2 0 -7 -8 -10 dB
qV opt 800 2 -3 -8 -8 -4 -6 -6 -9 -13 dB 1 0 -3 2 -5 -7 -8 -14 dB
qV opt 400 1 -6 -7 -2 -5 -4 -7 -11 -18 dB 2 -1 3 -4 -6 -6 -13 -18 dB
DX 1300 2 -8 -10 -15 -11 -6 -6 -7 -8 dB 1 -3 -5 -6 -2 -6 -7 -7 dB
DX 800 1 -9 -13 -12 -6 -7 -6 -7 -9 dB -1 -4 -7 -2 -5 -8 -7 -9 dB
DX 400 0 -12 -11 -5 -6 -5 -6 -8 -14 dB -3 -6 -1 -4 -7 -6 -9 -13 dB

26
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0500

Dimensions in mm, subject to change.


ADH E0-0500 57 kg
885 456 352 355
638 805 808
10

7
38
8
9
35h7

576

638
541
641
50

928

949
250

383
130 28

283
638
13 18 668
688 694 = =
734 530
ADH E2-0500 65 kg
885 807 810
40 638 352 355

10
10
38
8

9
35h7

638
541
641
50

931

949
530
250

130 28

280
638
13 18 668
688 694 530
718 756 51
ADH E4-0500 85 kg
920 807 810
40 638 352 355

10
12
43
8

9
40h7

638
541
641
70
931

949
530

250

130 28
280

638
13 18 668
688 694 530
718 756 51
ADH E6-0500 86 kg
920 807 810
40 638 352 355
10

12
43
8

9
40h7
638
541
641

70
931

949
530

250

130 28
280

638
13 18 668
688 694 530
718 756 51
ADH E7-0500 105 kg
960 807 810
40 638 352 355
53.5

10

14
9

9
50h7
638
541
641

90
931

949
530

250

130 28
280

638
13 18 668
688 694 530
718 756 51

27
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0560 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 560 mm Impeller weight m 24 kg
Number of blades z 42 Density of media r1 1.2 kg/m
Moment of Inertia J 1.560 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N ADHE4/E6/E7 only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N ADHE6/E7 only The AMCA Certified Ratings Seal applies to air performance ratings only.
Pa N ADHE7 only
4500 N do not use in this area
4000
r
3500

62
55

66

52
3000

63
37 45

39
1/min W W W W

56
2500 % 30
46
kW 1400 29 70 175 178
2000 1300 27 65 163 165
18.5
15 1200 25 60 150 152
1500
1100 23 55 138 140
11
1000 21 50 125 127
1000 7.5
105 dB 900 19 45 113 114
800 5.5
800 17 40 100 102
4.0
600 100
3.0 700 15 35 88 89
500
2.2
400 600 13 30 75 76

1.5 95

300 500 11 25 63 64

450 9 23 56 57
0.75 90
r
P

200
400 8 20 50 51

150
85 350 7 18 44 44
0.37
70
A7

65 75
LW

100 80 300 6 15 38 38

Normal operation area


ADH E0/E2
SX

DX

80
ADH E4

ADH E6

ADH E7
Pb
pF

60
4000 5000 6000 8000 10000 15000 20000 30000 40000 60000 80000 m/h
Measured in installation B
1 2 3 4 5 6 7 8 9 10 14 20 m/s
qV according to ISO5801:

2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

3 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1200 3 3 3 -2 -8 -5 -8 -8 -11 dB 8 8 2 0 -1 -8 -10 -12 dB
SX 800 2 4 2 -7 -4 -6 -7 -8 -13 dB 9 5 2 1 -5 -8 -10 -15 dB
SX 400 1 4 -5 -2 -4 -5 -7 -11 -17 dB 7 4 3 -3 -6 -8 -13 -20 dB
qV opt 1200 3 -1 -1 -5 -9 -4 -8 -8 -10 dB 6 6 0 -1 0 -7 -9 -10 dB
qV opt 800 2 0 -1 -9 -4 -6 -7 -8 -12 dB 7 3 0 2 -5 -8 -9 -13 dB
qV opt 400 1 0 -8 -2 -5 -5 -6 -11 -17 dB 5 2 4 -3 -6 -7 -12 -19 dB
DX 1200 4 -6 -6 -9 -12 -5 -7 -7 -7 dB 7 7 1 -3 0 -6 -8 -7 dB
DX 800 3 -6 -6 -13 -6 -6 -7 -7 -9 dB 8 3 -1 1 -5 -7 -7 -8 dB
DX 400 1 -5 -12 -5 -5 -6 -6 -8 -15 dB 4 0 2 -4 -6 -6 -7 -10 dB

28
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH E_-0560

Dimensions in mm, subject to change.


ADH E0-0560 72 kg
1000 511 390 393
715 897 900
12

7
43
8
9
40h7

643

715
606
716
70

1037

1058
250

425
130 28

315
715
13 18 745
765 771 = =
811 530
ADH E2-0560 86 kg
1000 901 904
50 715 390 393

13
12
43
8

9
40h7

715
606
716
70

1046

1061
530
250

130 28

317
715
13 18 745
765 771 530
815 851 50
ADH E4-0560 134 kg
1070 901 904
50 715 390 393
53.5

13
14
9

9
50h7

715
606
716
90
1046

1061
530

250

130 28
317

715
13 18 745
765 771 530
815 851 50
ADH E6-0560 142 kg
1070 901 904
50 715 390 393
53.5

13

14
9

9
50h7
715
606
716

90
1046

1061
530

250

130 28
317

715
13 18 745
765 771 530
815 851 50
ADH E7-0560 150 kg
1130 901 904
50 715 390 393
53.5

13

14
9

9
50h7
715
606
716

90
1046

1061
530

250

130 28
317

715
13 18 745
765 771 530
815 851 50

29
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH _-0630 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 632 mm Impeller weight m 32 kg
Number of blades z 38 Density of media r1 1.2 kg/m
Moment of Inertia J 2.590 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N ADHK/K1/K2 only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N ADHK1/K2 only The AMCA Certified Ratings Seal applies to air performance ratings only.
N ADHK2 only
Pa
N do not use in this area
4500
4000
3500 r

63
3000

53
67
63
55
2500 45

40
1/min W W W W
%

55
47

30 1200 25 60 150 152


2000
kW
1100 23 55 138 140
18.5
1500 15 1000 21 50 125 127

11 900 19 45 113 114

1000 800 17 40 100 101


7.5
800
5.5 700 15 35 88 89

600 4.0 100 dB


600 13 30 75 76
500 3.0

400 2.2 95
500 11 25 63 63

1.5
300 450 10 23 56 57
90
1.1
400 8 20 50 51

200 0.75
85 350 7 18 44 44
r
P

150
300 6 15 38 38
0.37 80
65 70
7
WA

100 75
L

250 5 13 31 32
80 Normal operation area
ADH L/R
DX

ADH K1

ADH K2
SX

ADH K

Pb
pF

60
4000 5000 6000 8000 10000 15000 20000 30000 40000 60000 80000 m/h
Measured in installation B
2 3 4 5 6 7 8 9 10 14 20 m/s according to ISO5801:
qV
2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

2 3 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1000 3 2 2 3 -3 -7 -9 -12 -17 dB 10 10 7 -1 -7 -9 -12 -17 dB
SX 600 2 4 5 2 -4 -6 -9 -13 -20 dB 12 11 4 -3 -6 -9 -13 -20 dB
SX 350 1 7 6 0 -3 -5 -9 -16 -22 dB 14 9 1 -3 -5 -9 -16 -22 dB
qV opt 1000 2 1 1 1 -3 -6 -8 -11 -17 dB 9 9 6 -1 -6 -8 -11 -17 dB
qV opt 600 1 3 4 1 -3 -6 -9 -13 -20 dB 11 9 3 -2 -5 -9 -13 -20 dB
qV opt 350 1 6 4 1 -2 -6 -9 -16 -22 dB 12 7 2 -2 -6 -9 -16 -22 dB
DX 1000 2 3 3 0 -5 -6 -8 -10 -12 dB 11 11 5 -3 -6 -8 -10 -12 dB
DX 600 1 4 4 -3 -4 -6 -8 -9 -16 dB 12 10 0 -3 -5 -8 -9 -15 dB
DX 350 1 6 1 -2 -3 -6 -7 -13 -19 dB 13 2 -1 -3 -6 -7 -13 -19 dB

30
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH _-0630

Dimensions in mm, subject to change.


ADH L-0630 91 kg
1085 571 434 437
801 992 995
12

43
8
9
40h7

707

801
679
801
70

1142

1170
300

468
130 28

346
801
13 18 831
851 857 = =
897 530
ADH R-0630 106 kg
1085 996 999
50 801 434 437
12
43
8

9
40h7

801
679
801
70

1157

1178
530
300

130 28

349
801
13 18 831
851 857 530
901 940 56
ADH K-0630 170 kg
1155 999 1002
50 801 434 437
53.5

14
9

9
50h7

801
679
801
90
1157

1179
530

300

130 28
350

801
13 18 831
851 857 530
901 940 59
ADH K1-0630 175 kg
1155 999 1002
50 801 434 437
53.5

14
9

9
50h7
801
679
801

90
1157

1179
530

300

130 28
350

801
13 18 831
851 857 530
901 940 59
ADH K2-0630 180 kg
1215 999 1002
50 801 434 437
53.5

14
9

9
50h7
801
679
801

90
1157

1179
530

300

130 28
350

801
13 18 831
851 857 530
901 940 59

31
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH _-0710 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 712 mm Impeller weight m 40 kg
Number of blades z 42 Density of media r1 1.2 kg/m
Moment of Inertia J 3.970 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N ADHK/K1/K2 only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N ADHK1/K2 only The AMCA Certified Ratings Seal applies to air performance ratings only.
N ADHK2 only
Pa
N do not use in this area
4500
4000
3500
3000 r

2500

63
67

52
55 75

62
2000 37
%

39
54

30 1/min W W W W
44

kW
22 950 48 48 161 56
1500 18.5 900 45 45 152 53
15 850 43 43 144 50
800 40 40 135 47
11 750 38 38 127 44
1000
700 35 35 118 41
800 7.5

5.5 600 30 30 101 35


600
4.0 100 dB
500
500 25 25 84 29
3.0
400
95 450 23 23 76 26
2.2

300 400 20 20 68 23
1.5
90
r
P

350 18 18 59 20
200
0.75
300 15 15 51 18
150 85

70
7

75
WA

250 13 13 42 15
L

80
100
Normal operation area
SX

DX

80
ADH L/R

ADH K1

ADH K2
ADH K

Pb
pF

60
5000 6000 8000 10000 15000 20000 30000 40000 60000 80000 100000 m/h
Measured in installation B
2 3 4 5 6 7 8 9 10 14 20 30 m/s according to ISO5801:
qV
2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

3 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point 1/min dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
SX 850 2 4 6 0 -1 -8 -10 -14 -20 dB 12 12 2 0 -7 -10 -14 -20 dB
SX 500 1 7 6 2 -3 -8 -10 -15 -21 dB 14 10 3 -2 -7 -10 -15 -21 dB
SX 300 1 11 6 3 -4 -6 -11 -17 -20 dB 15 7 3 -4 -6 -11 -17 -20 dB
qV opt 850 2 3 4 -2 -1 -7 -10 -13 -19 dB 10 10 1 0 -7 -10 -13 -19 dB
qV opt 500 1 6 4 2 -2 -7 -9 -15 -20 dB 13 7 3 -1 -7 -9 -15 -20 dB
qV opt 300 0 9 4 3 -4 -6 -11 -16 -20 dB 13 6 4 -4 -6 -11 -16 -20 dB
DX 850 2 7 6 -4 -3 -7 -8 -10 -14 dB 14 12 -1 -2 -7 -8 -10 -14 dB
DX 500 1 9 0 -2 -3 -6 -7 -10 -17 dB 16 4 0 -3 -6 -7 -10 -17 dB
DX 300 0 6 1 0 -4 -5 -7 -14 -18 dB 10 2 0 -4 -5 -7 -14 -18 dB

32
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH _-0710

Dimensions in mm, subject to change.


ADH L-0710 118 kg
1255 636 485 491
898 1114 1117

53.5
14

9
9
50h7

797

898
765
898
90

1287

1315
400

531
130 28

398
898
13 18 928
948 954 = =
998 630
ADH R-0710 135 kg
1255 1117 1120
50 898 485 488
53.5

14
9

9
50h7

898
765
898
90

1303

1324
630
400

130 28

398
898
17 22 928
948 954 630
998 1050 67
ADH K-0710 201 kg
1255 1121 1123
50 898 485 488
53.5

14
9

9
50h7

898
765
898
90
1303

1324
630

400

130 28
398

898
17 22 928
948 954 630
998 1050 71
ADH K1-0710 208 kg
1340 1121 1123
50 898 485 488
18
11
64

9
60h7
898
765
898

90
1303

1324
630

400

130 28
398

898
17 22 928
948 954 630
998 1050 71
ADH K2-0710 225 kg
1340 1121 1123
50 898 485 488
18
11
64

9
60h7
898
765
898

90
1303

1324
630

400

130 28
398

898
17 22 928
948 954 630
998 1050 71

33
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH _-0800 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 809 mm Impeller weight m 63 kg
Number of blades z 38 Density of media r1 1.2 kg/m
Moment of Inertia J 8.340 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N ADHK1/K2 only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N ADHK2 only The AMCA Certified Ratings Seal applies to air performance ratings only.
N do not use in this area
Pa
4500
4000
3500
r
3000

64
2500

53
75

68
64

39
55 1/min W W W
55
%

2000 kW 37
44

30 850 43 144 50
800 40 135 47
1500 22 750 38 127 44

15
650 33 110 38
1000
11 600 30 101 35
800 550 28 93 32
7.5
105 dB
500 25 85 29
600 5.5

500 450 23 76 26
4.0
100
400 3.0 400 20 68 23

2.2 350 18 59 21
300 95

1.5
300 15 51 18
r
P

200 1.1
90

0.75 250 13 42 15
150
7

85
WA
L

70 75
100 80 200 10 34 12

80 Normal operation area


ADH K1

ADH K2
DX

ADH K
SX

Pb
pF

60
6000 8000 10000 15000 20000 30000 40000 60000 80000 100000 m/h
Measured in installation B
2 3 4 5 6 7 8 9 10 14 20 30 40 m/s according to ISO5801:
qV
2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

2 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point 1/min dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
SX 750 2 5 7 -1 -1 -8 -10 -15 -20 dB 12 12 1 0 -8 -10 -15 -20 dB
SX 500 1 7 6 2 -3 -8 -10 -16 -21 dB 15 10 3 -2 -7 -10 -16 -21 dB
SX 300 1 11 6 2 -4 -6 -11 -17 -20 dB 16 7 3 -4 -6 -11 -17 -20 dB
qV opt 750 1 3 5 -2 -0 -8 -10 -14 -19 dB 11 10 0 0 -8 -10 -14 -19 dB
qV opt 500 1 6 4 2 -2 -7 -9 -15 -20 dB 13 7 3 -1 -7 -9 -15 -20 dB
qV opt 300 1 9 4 3 -4 -6 -10 -16 -20 dB 13 6 4 -4 -6 -10 -16 -20 dB
DX 750 2 7 5 -4 -3 -7 -8 -10 -15 dB 14 11 -2 -2 -7 -8 -10 -15 dB
DX 500 1 9 0 -2 -3 -6 -7 -11 -17 dB 16 4 -1 -3 -6 -7 -11 -17 dB
DX 300 0 6 1 -0 -4 -5 -7 -14 -19 dB 10 2 0 -4 -5 -7 -14 -19 dB

34
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH _-0800

Dimensions in mm, subject to change.


ADH K-0800 249 kg
1360 1255 1258
50 1007 540 543

53.5
14

9
9
50h7

1007
862
1007
90

1468

1489
710
500

130 28

454
1007
17 22 1037
1057 1063 710
1107 1181 74
ADH K1-0800 261 kg
1450 1255 1258
50 1007 540 543
18
11
64

9
60h7

1007
862
1007
90

1468

1489
710
500

130 28

454
1007
17 22 1037
1057 1063 710
1107 1181 74
ADH K2-0800 278 kg
1450 1255 1258
50 1007 540 543
18
11
64

9
60h7

1007
862
1007
90
1468

1489
710

500

130 28
454

1007
17 22 1037
1057 1063 710
1107 1181 74

35
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH _-0900 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 905 mm Impeller weight m 73 kg
Number of blades z 42 Density of media r1 1.2 kg/m
Moment of Inertia J 12.60 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N ADHK1/K2 only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N ADHK2 only The AMCA Certified Ratings Seal applies to air performance ratings only.
N do not use in this area
Pa
4500
4000
3500
r
3000

2500 110

64
68

53
75

64

39
2000 1/min W W W
%

57
49

45 750 60 127 44
kW
1500 30 700 56 118 41
650 52 110 38

18.5
1000
15 550 44 93 32

800 500 40 84 29
11

450 36 76 26
600 7.5 105 dB
500 400 32 68 23
5.5

400 4.0 100 350 28 59 20

3.0
300
300 24 51 18
2.2
95

200 1.5 250 20 42 15


r
P

1.1 90
150
0.75 200 16 34 12
7

85
WA

100 70 75
L

80 170 14 29 10
80
ADH K1

ADH K2
ADH K

Normal operation area


DX
SX

Pb
pF

60
8000 10000 15000 20000 30000 40000 60000 80000 100000 150000 m/h
Measured in installation B
3 4 5 6 7 8 9 10 14 20 30 40 50 m/s according to ISO5801:
qV
2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

2 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point 1/min dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
SX 650 2 6 7 1 -2 -8 -10 -15 -21 dB 13 12 3 -1 -8 -10 -15 -21 dB
SX 400 1 11 3 4 -4 -6 -11 -16 -20 dB 17 5 4 -4 -6 -11 -16 -20 dB
SX 250 0 11 6 2 -3 -6 -11 -17 -21 dB 14 8 2 -3 -6 -11 -17 -21 dB
qV opt 650 1 4 5 0 -1 -8 -10 -14 -20 dB 11 10 1 0 -8 -10 -14 -20 dB
qV opt 400 1 8 1 4 -4 -6 -10 -15 -20 dB 14 4 4 -4 -6 -10 -15 -20 dB
qV opt 250 0 8 6 2 -4 -6 -11 -17 -21 dB 11 7 3 -3 -6 -11 -17 -21 dB
DX 650 1 8 5 -2 -3 -7 -7 -10 -16 dB 15 9 -1 -2 -7 -7 -10 -16 dB
DX 400 1 8 -2 0 -5 -5 -7 -12 -18 dB 14 1 1 -4 -5 -7 -12 -18 dB
DX 250 0 3 1 -1 -4 -5 -8 -14 -19 dB 6 2 0 -4 -5 -8 -14 -19 dB

36
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH _-0900

Dimensions in mm, subject to change.


ADH K-0900 306 kg
1520 1408 1411
50 1130 604 607
18

11
64
9
60h7

1130
971
1130
90

1648

1669
800
600

130 28

511
1130
17 22 1160
1180 1186 800
1230 1319 89
ADH K1-0900 316 kg
1520 1408 1411
50 1130 604 607
18
11
64

9
60h7

1130
971
1130
90

1648

1669
800
600

130 28

511
1130
17 22 1160
1180 1186 800
1230 1319 89
ADH K2-0900 320 kg
1570 1408 1411
50 1130 604 607
18
11
64

9
60h7

1130
971
1130
90
1648

1669
800

600

130 28
511

1130
17 22 1160
1180 1186 800
1230 1319 89

37
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH _-1000 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 995 mm Impeller weight m 89 kg
Number of blades z 46 Density of media r1 1.2 kg/m
Moment of Inertia J 18.70 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N ADHK2 only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N do not use in this area The AMCA Certified Ratings Seal applies to air performance ratings only.
Pa
4500
4000
3500
r
3000

65

55
69
2500

42
110 1/min W W

64
54 75 700 56 41
%

2000 kW
43

55 650 52 38
45
1500 600 48 35
37
550 44 32
30
500 40 29
1000 22
450 36 26
800
15
400 32 23
600 11
105 dB
500 350 28 21
7.5

400 5.5
100 300 24 18

4.0
300
3.0 250 20 15
95
2.2
200
r
P

200 16 12
90
150
1.1

75 80
7

160 13 9
WA

100 85
L

Normal operation area


DX

80
ADH K2
ADH K
SX

Pb
pF

60
10000 15000 20000 30000 40000 60000 80000 100000 150000 200000 m/h
Measured in installation B
3 4 5 6 7 8 9 10 14 20 30 40 50 60 70 m/s according to ISO5801:
qV
2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

2 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point 1/min dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
SX 600 2 7 7 1 -2 -8 -10 -15 -21 dB 14 12 3 -2 -8 -10 -15 -21 dB
SX 400 1 11 3 4 -4 -6 -11 -16 -20 dB 17 5 4 -4 -6 -10 -16 -20 dB
SX 200 0 7 8 0 -2 -6 -12 -16 -22 dB 9 8 0 -2 -6 -12 -16 -22 dB
qV opt 600 1 5 5 0 -1 -8 -10 -15 -20 dB 12 9 2 -1 -8 -10 -15 -20 dB
qV opt 400 1 8 1 4 -4 -6 -10 -15 -20 dB 14 4 4 -4 -6 -10 -15 -20 dB
qV opt 200 0 5 8 0 -2 -6 -11 -16 -22 dB 8 8 0 -2 -6 -11 -16 -22 dB
DX 600 1 8 4 -2 -3 -7 -7 -10 -17 dB 15 8 0 -3 -7 -7 -10 -17 dB
DX 400 1 8 -2 0 -5 -5 -7 -12 -18 dB 14 1 1 -4 -5 -7 -12 -18 dB
DX 200 0 1 3 -2 -2 -5 -9 -15 -20 dB 3 4 -2 -2 -5 -9 -15 -20 dB

38
Belt Driven Centrifugal Fans / ADH / Technical Data

ADH _-1000

Dimensions in mm, subject to change.


ADH K-1000 333 kg
1660 1541 1544
50 1267 657 660
18

11
64
9
60h7

1267
1066
1267
90

1810

1829
900
700

130 28

534
1267
17 22 1297
1317 1323 900
1367 1451 90
ADH K1-1000 356 kg
1660 1541 1544
50 1267 657 660
18
11
64

9
60h7

1267
1066
1267
90

1810

1829
900
700

130 28

534
1267
17 22 1297
1317 1323 900
1367 1451 90
ADH K2-1000 360 kg
1700 1541 1544
50 1267 657 660
18
11
64

9
60h7

1267
1066
1267
90
1810

1829
900

700

130 28
534

1267
17 22 1297
1317 1323 900
1367 1451 90

39
Belt Driven Centrifugal Fans / ADH / Twin fan arrangement

ADH G2E0

Dimensions in mm, subject to change.


ADH G2E0-0160/-0500
M X4 G G1
E V E K A A1

S
X3

A2
w t

F
C
B

B1
z
dh7

X2
165 28

Q
max.
P = =
L US X1

ADH G2E0-0160/-0355 ADH G2E0-0400/-0500


13 C2 C2 13 13 C2 E2 C2 13

9 B2 9

B2
A2 A2

ADH G2E0-0160/-0500
A B C E F G L M P Q
0160 290 310 205 205 173 141 630 710 600 121
0180 319 344 227 229 195 154 698 780 668 135
0200 348 378 258 256 216 163 772 876 742 144
0225 388 422 287 288 241 182 861 965 831 156
0250 423 467 322 322 268 195 954 1036 924 161
0280 471 524 361 361 302 215 1062 1160 1032 183
0315 522 586 403 404 338 236 1183 1301 1153 202
0355 582 658 450 453 381 261 1341 1451 1301 212
0400 654 745 507 507 432 290 1494 1606 1454 234
0450 732 838 571 569 487 322 1684 1790 1638 260
0500 805 928 641 638 541 352 1872 1986 1826 283

S V K X1 X2 X3 X4 t w
0160 7 160 70 180 153 207 153 6 30
0180 7 180 71 180 167 227 167 6 30
0200 6 200 82 224 186 250 189 6 30
0225 7 225 82 224 202 279 209 6 30
0250 7 250 71 224 215 304 232 6 30
0280 6 280 79 280 242 337 261 8 40
0315 7 315 89 280 267 376 289 8 40
0355 7 355 95 355 281 418 327 8 40
0400 7 400 96 355 309 469 366 8 40
0450 7 450 101 530 344 526 415 10 50
0500 7 500 105 530 383 576 456 10 50

z d us A1 B1 G1 A2 B2 C2 E2
0160 22.5 20h7 11 16 293 331 144 205 261 117.5
0180 22.5 20h7 11 16 322 365 157 229 285 129.5
0200 22.5 20h7 11 16 351 400 166 256 312 143
0225 22.5 20h7 11 16 391 443 185 288 344 159
0250 22.5 20h7 11 16 426 488 198 322 378 176
0280 28 25h7 11 16 474 546 218 361 417 195.5
0315 28 25h7 11 16 525 607 239 404 460 217
0355 33 30h7 11 16 585 679 264 453 509 241.5
0400 33 30h7 11 16 657 766 293 507 563 168.5 200
0450 38 35h7 13 18 735 859 325 569 625 199.5 200
0500 38 35h7 13 18 808 949 355 638 694 209 250

40
Belt Driven Centrifugal Fans / ADH / Twin fan arrangement

ADH G2E2 / ADH G2R

Dimensions in mm, subject to change.


ADH G2E2-0160/-0560 / ADH G2R-0630
M H H1
E V E K G G1

S
=

A2
w t

F
C
B

B1
X2
z
dh7
165 28

Q
max.

=
P X3 P = X1 =
L US A R

ADH G2E2-0160/-0355 ADH G2E2-0400/-0560 / ADH G2R-0630


13 C2 C2 13 13 C2 E2 C2 13

9 9

B2

B2
A2 A2

ADH G2E2-0160/-0560 / ADH G2R-0630


A B C E F G H L M P
0160 267 315 205 205 173 141 293 610 710 229
0180 294 350 227 229 195 154 322 678 780 253
0200 316 383 258 256 216 163 350 762 876 286
0225 355 429 287 288 241 182 392 851 965 318
0250 390 474 322 322 268 195 427 944 1036 352
0280 439 530 361 361 302 215 474 1062 1164 391
0315 490 592 403 404 338 236 526 1180 1300 434
0355 551 669 450 453 381 261 588 1337 1451 493
0400 618 754 507 507 432 290 659 1494 1606 547
0450 691 845 571 569 487 322 735 1668 1790 619
0500 760 935 641 638 541 352 809 1854 1986 688
0560 855 1050 716 715 606 390 903 2090 2276 765
0630 940 1157 801 801 679 434 996 2332 2575 851

Q R S V K X1 X2 X3 t w
0160 98 26 10 160 50 180 180 136 6 30
0180 113 28 8 180 51 180 180 156 6 30
0200 115 34 8 200 57 224 224 170 6 30
0225 129 37 11 225 57 224 224 195 6 30
0250 140 37 10 250 46 224 224 220 6 30
0280 158 35 9 280 51 280 280 250 8 40
0315 177 36 10 315 60 280 280 285 8 40
0355 204 37 13 355 57 355 355 315 8 40
0400 234 41 11 400 56 355 355 360 8 40
0450 261 44 11 450 61 530 530 400 10 50
0500 282 49 10 500 66 530 530 450 10 50
0560 319 48 13 560 93 530 530 510 12 70
0630 349 56 7 630 121 530 530 580 12 70

z d us B1 H1 G1 A2 B2 C2 E2
0160 22.5 20h7 9 14 331 296 144 205 261 117.5
0180 22.5 20h7 9 14 368 325 157 229 285 129.5
0200 22.5 20h7 11 16 401 353 166 256 312 143
0225 22.5 20h7 11 16 444 395 185 288 344 159
0250 22.5 20h7 11 16 490 430 198 322 378 176
0280 28 25h7 13 18 547 477 218 361 417 195.5
0315 28 25h7 13 18 608 529 239 404 460 217
0355 33 30h7 13 18 682 591 264 453 509 241.5
0400 33 30h7 13 18 769 662 293 507 563 168.5 200
0450 38 35h7 13 18 860 738 325 569 625 199.5 200
0500 38 35h7 13 18 951 812 355 638 694 209 250
0560 43 40h7 13 18 1063 906 393 715 771 247.5 250
0630 43 40h7 13 18 1178 999 437 801 857 265.5 300

41
Belt Driven Centrifugal Fans / ADH / Twin fan arrangement

ADH G2E4 / ADH G2K

Dimensions in mm, subject to change.


ADH G2E4-0250/-0560 / ADH G2K-0630/-1000
M H H1
E V E K G G1

S
=

A2
w t

F
C
B

B1
X2
z
dh7
165 28

Q
max.

=
P X3 P = X1 =
L US A R

ADH G2E4-0250/-0355 ADH G2E4-0400/-0560 ADH G2K-0630 ADH G2K-0710/-1000


13 C2 C2 13 13 C2 E2 C2 13 13 C2 E2 C2 13 13 C2 E2 C2 13
= =

9 9 9 9
B2

B2

B2

B2
A2 A2 A2 A2

ADH G2E4-0250/-0560 / ADH G2K-0630/-1000


A B C E F G H L M P
0250 390 474 322 322 268 195 427 943 1085 352
0280 439 530 361 361 302 215 474 1062 1220 391
0315 490 592 403 404 338 236 526 1182 1340 434
0355 551 669 450 453 381 261 588 1341 1505 493
0400 618 754 507 507 432 290 659 1494 1660 547
0450 691 845 571 569 487 322 735 1668 1870 619
0500 760 935 641 638 541 352 809 1856 2060 688
0560 855 1050 716 715 606 390 903 2090 2330 765
0630 940 1157 801 801 679 434 1005 2332 2576 851
0710 1050 1303 898 898 765 485 1121 2606 2898 948
0800 1181 1468 1007 1007 862 540 1255 2914 3257 1057
0900 1319 1648 1130 1130 971 604 1408 3260 3550 1180
1000 1451 1810 1267 1267 1066 657 1541 3634 3927 1317

Q R S V K X1 X2 X3 t t1 w
0250 140 37 10 250 71 224 224 220 8 7 40
0280 158 35 9 280 79 280 280 250 8 7 40
0315 177 36 10 315 79 280 280 285 8 7 40
0355 204 37 13 355 82 355 355 315 10 8 50
0400 234 41 11 400 83 355 355 360 10 8 50
0450 261 44 11 450 101 530 530 400 12 8 70
0500 282 49 10 500 102 530 530 450 12 8 70
0560 319 48 13 560 120 530 530 510 14 9 90
0630 349 59 7 630 122 530 530 580 14 9 90
0710 398 71 7 710 146 630 630 660 18 11 91
0800 453 74 8 800 172 710 710 750 18 11 91
0900 510 89 8 900 145 800 800 850 18 11 91
1000 534 90 9 1000 147 900 900 950 18 11 91

z d us B1 H1 G1 A2 B2 C2 E2
0250 28 25h7 11 16 490 430 198 322 378 176.0
0280 33 30h7 13 18 547 477 218 361 417 195.5
0315 33 30h7 13 18 608 529 239 404 460 217.0
0355 38 35h7 13 18 682 591 264 453 509 241.5
0400 38 35h7 13 18 769 662 293 507 563 168.5 200
0450 43 40h7 13 18 860 738 325 569 625 199.5 200
0500 43 40h7 13 18 951 812 355 638 694 209.0 250
0560 53.5 50h7 13 18 1063 906 393 715 771 247.5 250
0630 53.5 50h7 13 18 1179 1008 437 801 857 265.5 300
0710 64 60h7 17 22 1391 1124 488 898 954 264.0 400
0800 64 60h7 17 22 1561 1258 543 1007 1063 268.5 500
0900 64 60h7 17 22 1748 1411 607 1130 1186 280.0 600
1000 64 60h7 17 22 1930 1544 660 1267 1323 298.5 700

42
Belt Driven Centrifugal Fans / ADH / Twin fan arrangement

ADH G2E7 / ADH G2K2

Dimensions in mm, subject to change.


ADH G2E7-0250/-0560 / ADH G2K2-0630/-1000
M H H1
E V E K G G1

S
=

A2
w t

F
C
B

B1
X2
z
dh7
165 28

Q
max.

=
P X3 P = X1 =
L US A R

ADH G2E7-0250/-0355 ADH G2E7-0400/-0560 ADH G2K2-0630 ADH G2K2-0710/-1000


13 C2 C2 13 13 C2 E2 C2 13 13 C2 E2 C2 13 13 C2 E2 C2 13
= =

9 9 9 9
B2

B2

B2

B2
A2 A2 A2 A2

ADH G2E7-0250/-0560 / ADH G2K2-0630/-1000


A B C E F G H L M P
0250 390 474 322 322 268 195 427 943 1085 352
0280 439 530 361 361 302 215 474 1062 1230 391
0315 490 592 403 404 338 236 526 1182 1400 434
0355 551 669 450 453 381 261 588 1341 1545 493
0400 618 754 507 507 432 290 659 1494 1800 547
0450 691 845 571 569 487 322 735 1668 1924 619
0500 760 935 641 638 541 352 809 1856 2146 688
0560 855 1050 716 715 606 390 903 2090 2380 765
0630 940 1157 801 801 679 434 1005 2332 2576 851
0710 1050 1303 898 898 765 485 1121 2606 2898 948
0800 1181 1468 1007 1007 862 540 1255 2914 3257 1057
0900 1319 1648 1130 1130 971 604 1408 3260 3550 1180
1000 1451 1810 1267 1267 1066 657 1541 3634 3927 1317

Q R S V K X1 X2 X3 t w
0250 140 37 10 250 71 224 224 220 8 40
0280 158 35 9 280 84 280 280 250 10 50
0315 177 36 10 315 109 280 280 285 12 70
0355 204 37 13 355 102 355 355 315 12 70
0400 234 41 11 400 153 355 355 360 14 90
0450 261 44 11 450 128 530 530 400 14 90
0500 282 49 10 500 145 530 530 450 18 90
0560 319 48 13 560 145 530 530 510 18 90
0630 349 59 7 630 122 530 530 580 18 91
0710 398 71 7 710 146 630 630 660 18 91
0800 453 74 8 800 172 710 710 750 18 91
0900 510 89 8 900 145 800 800 850 18 91
1000 534 90 9 1000 147 900 900 950 18 91

z d us B1 H1 G1 A2 B2 C2 E2
0250 33 30h7 11 16 490 430 198 322 378 176.0
0280 38 35h7 13 18 547 477 218 361 417 195.5
0315 43 40h7 13 18 608 529 239 404 460 217.0
0355 43 40h7 13 18 682 591 264 453 509 241.5
0400 53.5 50h7 13 18 769 662 293 507 563 168.5 200
0450 53.5 50h7 13 18 860 738 325 569 625 199.5 200
0500 64 60h7 13 18 951 812 355 638 694 209.0 250
0560 64 60h7 13 18 1063 906 393 715 771 247.5 250
0630 64 60h7 13 18 1179 1008 437 801 857 265.5 300
0710 64 60h7 17 22 1391 1124 488 898 954 264.0 400
0800 64 60h7 17 22 1561 1258 543 1007 1063 268.5 500
0900 64 60h7 17 22 1748 1411 607 1130 1186 280.0 600
1000 64 60h7 17 22 1930 1544 660 1267 1323 298.5 700

43
Belt Driven Centrifugal Fans / ADH / Specifications

ADH E0-0160/-0560 ADH G2E0-0160/-0500


ADH L-0630/-0710
Specifications
High performance centrifugal fan ADHE0 / ADHL
Double inlet, belt drive.
Lap jointed scroll of galvanised sheet steel assembled through a standing-seam
(Sizes 0160/-0560) or by Pittsburgh lockforming (sizes 0630/-0710).
Multi-position feet and discharge flange as an option.
Impeller with forward curved blades of galvanised sheet steel, balanced in according
to ISO1940.
Straight cut off at fan discharge (sizes 0160/-0560), from size 0630 with V-cut off.
Noise tested, maintenance free, self aligning radial insert ball bearings, mounted in
pressed steel housing/strut assemblies with rubber interliners.
Performance data in according to DIN24166 tolerance class 2.

Twin fan arrangement


Twin fan arrangement
High performance centrifugal fan ADH G2E0
The two single fans ADHE0 are fitted together to a robust assembly by means of
3 U-channels. Both impellers are fitted on a common shaft supported by 3 bearings.

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Multi-Position feet
Discharge flange
Discharge flex with flexible sleeve
Inlet guard
Discharge guard
Shaft guard for free shaft end
Matching flange
Inspection door
Drain plug R1/8"
Increase corrosion protection
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone, or equipped with a copper strip (from size 0630)

44
Belt Driven Centrifugal Fans / ADH / Specifications

ADH E2-0160/-0560 ADH G2E2-0160/-0560


ADH R-0630/-0710 ADH G2R-0630
Specifications
High performance centrifugal fan ADHE2 / ADHR
Double inlet, belt drive.
Lap jointed scroll of galvanised sheet steel assembled through a standing-seam
(Sizes 0160/-0560) or by Pittsburgh lockforming (sizes 0630/-0710), discharge flange
as an option.
Rectangular side frame of galvanised steel.
Impeller with forward curved blades of galvanised sheet steel, balanced in according
to ISO1940. Straight cut off at fan discharge (sizes 0160/-0560), from size 0630 with
V-cut off.
Noise tested, maintenance free, self aligning radial insert ball bearings, mounted in
pressed steel housing/strut assemblies with rubber interliners.
Performance data in according to DIN24166 tolerance class 2.

Twin fan arrangement


Twin fan arrangement
High performance centrifugal fan ADH G2E2 / ADH G2R
The two single fans ADHE2 or ADHR are fitted together to a robust assembly by
means of 3 angle bars. Both impellers are fitted on a common shaft supported by 3
bearings.

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Discharge flange
Discharge flex with flexible sleeve
Inlet guard
Discharge guard
Shaft guard for free shaft end
Matching flange
Inspection door
Drain plug R1/8"
Increase corrosion protection
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone, or equipped with a copper strip (from size 0630)

45
Belt Driven Centrifugal Fans / ADH / Specifications

ADH E4-0200/-0560 ADH G2E4-0250/-0560


ADH K-0630/-1000 ADH G2K-0630/-1000
Specifications
High performance centrifugal fan ADHE4 / ADHK
Double inlet, belt drive.
Lap jointed scroll of galvanised sheet steel assembled through a standing-seam
(Sizes 0200/-0560) or by Pittsburgh lockforming (sizes 0630/-1000), discharge flange
as an option.
Welded heavy duty reinforced side frames, coated.
Impeller with forward curved blades of galvanised sheet steel, balanced in according
to ISO1940. Straight cut off at fan discharge (sizes 0200/-0560), from size 0630 with
V-cut off.
Monobloc pedestal cast iron bearings with relubrication nipple, mounted on a robust
pedestal, integrated, self aligning radial insert ball bearings fixed by eccentric clamp.
Performance data in according to DIN24166 tolerance class 2.

Twin fan arrangement


Twin fan arrangement
High performance centrifugal fanADH G2E4 / G2K
The two single fans ADHE4 or ADHK are fitted together to a robust assembly by
means of 3 angle bars. Both impellers are fitted on a common shaft supported by 3
bearings (sizes 0250/-0630) or the fans have separated shafts being connected by an
elastic coupling (sizes 0710/-1000).

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Discharge flange
Discharge flex with flexible sleeve
Inlet guard
Discharge guard
Shaft guard for free shaft end
Matching flange
Inspection door
Drain plug R1/8"
Reinforcing side frame hot dip galvanised
Increase corrosion protection
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone, or equipped with a copper strip (from size 0630)

46
Belt Driven Centrifugal Fans / ADH / Specifications

ADH E6-0315/-0560
ADH K1-0630/-0900
Specifications
High performance centrifugal fan ADHE6 / ADHK1
Double inlet, belt drive.
Lap jointed scroll of galvanised sheet steel assembled through a standing-seam
(Sizes 0315/-0560) or by Pittsburgh lockforming (sizes 0630/-1000), discharge flange
as an option.
Welded heavy duty reinforced side frames, coated.
Impeller with forward curved blades of galvanised sheet steel, balanced in according
to ISO1940.
Straight cut off at fan discharge (sizes 0315/-0560), from size 0630 with V-cut off.
Monobloc pedestal cast iron bearings with relubrication nipple, mounted on a robust
pedestal, integrated, self aligning radial ball bearings fixed by conical sleeve.
Performance data in according to DIN24166 tolerance class 2.

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Discharge flange
Discharge flex with flexible sleeve
Inlet guard
Discharge guard
Shaft guard for free shaft end
Matching flange
Inspection door
Drain plug R1/8"
Reinforcing side frame hot dip galvanised
Increase corrosion protection
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone, or equipped with a copper strip (from size 0630)

47
Belt Driven Centrifugal Fans / ADH / Specifications

ADH E7-0500/-0560
ADH K2-0630/-1000
Specifications
High performance centrifugal fan ADHE7 / ADHK2
Double inlet, belt drive.
Lap jointed scroll of galvanised sheet steel assembled through a standing-seam (sizes
0500/-0560) or by Pittsburgh lockforming (sizes 0630/-1000), discharge flange as an
option.
Welded heavy duty reinforced side frames, coated.
Impeller with forward curved blades of galvanised sheet steel, balanced in according
to ISO1940. Straight cut off at fan discharge (sizes 0500/-0560), from size 0630 with
V-cut off.

Size 0500
Monobloc pedestal cast iron bearings with relubrication nipple, mounted on a robust
pedestal, integrated, maintenance free, self aligning radial insert ball bearings fixed by
conical sleeve
Sizes 0560 up to 0800
Split pedestal cast iron bearings with relubrication nipple, mounted on a robust pe-
destal, integrated self aligning double row bearings fixed by conical sleeve, lubricated
with long life high performance grease.
Sizes 0900 and 1000
Single piece plummer block housing, with grease nipple, mounted on robust pedes-
tal, equipped with self aligning double row roller bearing, fixed to impeller shaft by a
concentric shaft tightening, lubricated with long life high performance grease.

Performance data in according to DIN24166 tolerance class 2.

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Discharge flange
Discharge flex with flexible sleeve
Inlet guard
Discharge guard
Shaft guard for free shaft end
Matching flange
Inspection door
Drain plug R1/8"
Reinforcing side frame hot dip galvanised
Increase corrosion protection
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Threaded hole for measurement of shock impulse (sizes 0560 up to 1000)
Aluminium inlet cone
Copper inlet cone, or equipped with a copper strip (from size 0630)

48
Belt Driven Centrifugal Fans / ADH / Specifications

ADH G2E7-0250/-0560
ADH G2K2-0630/-1000
Specifications
Centrifugal twin fan ADH G2E7 / ADH G2K2
Double inlet, belt drive.
Lap jointed scroll of galvanised sheet steel assembled through a standing-seam
(Sizes 0250/-0560) or by Pittsburgh lockforming (sizes 0630/-1000), fitted together to
a robust assembly by means of 3 crossbars, discharge flange as an option.
Welden heavy duty reinforced side frames, coated.
Both impellers, with forward curved blades, made of galvanised sheet steel, are fitted
on a common shaft supported by 3 bearings (sizes 0250/-0630) or the fans have
separated shafts being connected by a flexible coupling (sizes 0710/-1000), balanced
in according to ISO1940.
Straight cut off at fan discharge (sizes 0250/-0560), from size 0630 with V-cut off.

Sizes 0250 up to 0630


Single piece cast iron block housing with relubrication nipple, mounted on a robust
pedestal, integrated, maintenance free, self aligning radial insert ball bearings fixed by
conical sleeve.
Sizes 0710 up to 1000
Single piece cast iron block housing with relubrication nipple, mounted on a robust
pedestal,
outside bearings: integrated self aligning double row roller bearings, fixed by conical
sleeve, lubricated with long life high performance grease.
inside bearings: integrated single row ball bearings, fixed by eccentric clamp, lubrica-
ted with long life high performance grease.

Performance data in according to DIN24166 tolerance class 2.

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Discharge flange
Discharge flex with flexible sleeve
Inlet guard
Discharge guard
Shaft guard for free shaft end
Matching flange
Inspection door
Drain plug R1/8"
Reinforcing side frame hot dip galvanised
Increase corrosion protection
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Threaded hole for measurement of shock impulse (sizes 0560 up to 1000)
Aluminium inlet cone
Copper inlet cone, or equipped with a copper strip (from size 0630)

49
The NicotraGebhardt best-sellers, simply!

The series AT
Fans of AT series dont need any presentation: they have been one of the main
strengths in the NicotraGebhardt product range for over 35 years and have long
been appreciated for their unequalled combination of compactness, efficiency, quiet-
ness of operation and versatility, at an extremely affordable price.

News
How we can improve a perfect fan?
We tried, anyway: we developed a new seaming process, to join the back plate to the
side plates with a fully automated process.
The result is a new scroll without welding and whatever can become rusty, also provi-
ding a better structural strength to vibrations.
And, since we like to be coherent, we even deleted welding of the side frames, which
are now screwed to scrolls, and from spars, now riveted.

Searching for excellence


Who have say that a product with a nice price cannot be a nice product?
The success of the AT series confirm is the real proof: the bearings have been selec-
ted to achieve, at maximum load and with suitable pulleys, a bearing life of 40.000
hours, a number that can be considerably greater in more common load conditions.
Top quality materials, innovative technology of scroll and impeller manufacturing and
assembly, high efficiency, options and accessories, everything has been chosen to
provide a long operating life time, with the maximum quietness and safety.

Complete range
Arent you convinced?
Have a look to the range of the AT fans, you immediately realize that, as far as we
can, were doing our best to try and meet all your requirements.
We have single, twin and triple fans, with or without side frames, with one, two or
three bearings for light or heavy duty, we have versions with hollow shafts, when there
is the need of reducing the weight without reducing the fan performance, and also
spark-proof versions.
Do you still think that we dont have the right fan for you?

50
Product overview

range AT
This kind of fans are specially conceived for mechanical ventilation, at temperatures from -20C to +40C on S, SC, G2L and SC2 models, or
up to 100C on AR, TIC, G2C, G2C-C2, G3C, G3C-C2 models.
Air performance and sound data have been obtained in a laboratory registered by AMCA for AMCA210/99 air performance testing and they are
within the tolerances allowed by the DIN24166 standard for Class 2.

Single, twin and triple fans Single, twin and triple fans.
Impeller size (diameter/width) from 7/7 to 30/28 Airflow up to 180.000 m/h
Lap-jointed scroll of galvanized steel assembled with roller-lock Total pressure up to 1.400 Pa
seaming (sizes up to 18/18) or with Pittsburgh lock seam (for sizes
larger than 18/18)
Straight cut off plate at fan outlet
Impeller with forward curved blades of galvanized steel, optimized for
the best efficiency and quietness
Galvanized steel shaft

The variety
We have the right fan for all your applications!
Depending on the fan size, five single fan versions, four twin fan versions and two triple fan versions are available in the AT range.

Version Description Figure

Light construction, without feet and outlet flange.Light-duty bearing and pressed steel bearing
AT S
supporting brackets.

With rectangular side frame and without outlet flange.Light-duty bearing and pressed steel
AT SC bearing supporting brackets. C version has also three steel bars with the ends welded to three
corners of both the side frames.

With heavy duty reinforced side frames, joined by three steel bars in three corners and without
AT AR outlet flange. Medium duty bearing inside lubricatable, cast iron pillow block, mounted on a
robust cross-bar.

With heavy duty reinforced side frames, joined by four steel bars in four corners and without
AT TIC outlet flange. Medium-heavy duty bearing inside lubricatable, cast iron pillow block, mounted
on a robust cross-bar.

Version Description Figure

Two S-version single fans joined together by three U-section spars. The two impellers are
AT G2L
mounted on a common shaft, supported by three bearings.

Two SC-version single fans joined together by three L-section spars. The two impellers are
AT SC2
mounted on a common shaft, supported by three bearings.

Two single fans mounted side-by-side inside a common supporting frame of three L-section
AT G2C spars. The two impellers are mounted on a common shaft, supported at the ends by just two
bearings.Use of hollow shafts on the larger sizes.

Mechanically similar to G2C fans but stronger, thanks to the use of hollow shafts with larger
AT G2C-C2
diameter (45 mm) journals and plummer blocks with heavy-duty bearings.

51
Belt Driven Centrifugal Fans / AT / Technical Data

AT7/7 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 200 mm Impeller weight m 1.25 kg
Number of blades z 46 Density of media r1 1.2 kg/m
Moment of Inertia J 0.009 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N do not use in this area Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to air performance ratings only.

2000 r
Pa

59
3.0

54
2.2

56
1.1

%
1.5

48
1500 kW

40

42
0.75 4.0

0.55

29
1000 1/min W W
3000 20 20
800 0.37
2800 19 19
2600 17 17
600 0.25
2400 16 16
95 dB
500 0.18
2200 15 15

400 2000 13 13
0.12

1800 12 12
300 90

1600 11 11
0.06

200 9 9
1400
0.04 85

150
1200 8 8

0.02 80
r
P

100 1000 7 7

80
0.01 75
60 800 5 5

55
50 60 700 5 5
A7

70
SX

LW

40 Normal operation area 65


AT SC

600 4 4
AT S

Pb
pF

DX

30
150 200 300 400 500 600 800 1000 1500 2000 3000 4000 5000 m/h
Measured in
0.06 0.08 0.1 0.2 0.4 0.6 0.8 1 m/s installation B
qV
according to
0.9 1 1.4 2 3 4 5 6 7 8 9 10 14 20 30 m/s ISO5801:
v2

0.6 0.8 1 2 3 4 6 8 10 20 40 60 80 100 200 400 600 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 2200 3 -2 -7 0 -8 -8 -6 -7 -12 dB 9 2 6 -4 -5 -4 -5 -10 dB
SX 1400 3 -6 -1 -3 -8 -6 -5 -10 -14 dB 3 6 2 -5 -4 -3 -8 -13 dB
SX 800 2 -2 2 -8 -5 -3 -8 -12 -18 dB 5 7 -5 -3 -2 -6 -10 -16 dB
qV opt 2200 3 -4 -10 0 -9 -9 -6 -7 -11 dB 6 -2 6 -5 -6 -5 -5 -9 dB
qV opt 1400 2 -9 -2 -3 -9 -6 -5 -9 -13 dB 0 4 1 -6 -5 -4 -7 -11 dB
qV opt 800 2 -5 2 -9 -6 -4 -7 -11 -17 dB 2 6 -6 -4 -3 -6 -10 -16 dB
DX 2200 3 -7 -12 -4 -8 -10 -7 -6 -7 dB 3 -4 1 -4 -6 -5 -4 -6 dB
DX 1400 2 -11 -7 -4 -11 -8 -6 -6 -8 dB -3 -2 0 -7 -5 -4 -5 -7 dB
DX 800 2 -9 -3 -11 -8 -6 -6 -8 -11 dB -3 2 -7 -5 -3 -4 -6 -11 dB

52
Belt Driven Centrifugal Fans / AT / Technical Data

AT7/7

Dimensions in mm, subject to change.


AT S-7/7 5 kg
316 319
153 156
340
232 117

17
19
9

115.5 115.5
20

203

186
257
201

208
28

350
325
86

47
145
172 224 28
232
258 11 16 131 131
288 88 6
282 225
169 147
AT SC-7/7 6 kg

394 321 324


232 59 153 156

6
19

9 115.5 115.5

=
20

186
257
201

208
35

350
262
337

172 224 28
232
=

254 9 12 131 131 = =


210
272 288 36
285

53
Belt Driven Centrifugal Fans / AT / Technical Data

AT 9/7 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 242 mm Impeller weight m 2.3 kg
Number of blades z 43 Density of media r1 1.2 kg/m
Moment of Inertia J 0.029 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N AT AR only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N do not use in this area The AMCA Certified Ratings Seal applies to air performance ratings only.

r
2500 5.5
7.5

65

56
Pa

68
3.0

44
1/min W W W

64
2000 2.2
%

57 2800 19 19 34
48

kW 1.5
1500 1.1
2500 17 17 30
100 dB
0.75
2200 15 15 26
1000
0.55 2000 13 13 24
800 95
0.37 1800 12 12 22

600 1600 11 11 19
0.25
500
0.18 90 1400 9 9 17
400
0.12 8 8 14
1200
300
85

1000 7 7 12
0.06
200
80
r
P

150 800 5 5 10
0.03

75
0.02
100
A7
LW

60 65
80 600 4 4 7
70
Normal operation area
DX
SX

60
AT SC

AT AR
AT S

Pb
pF

50
300 400 500 600 800 1000 1500 2000 3000 4000 5000 6000 m/h

0.1 0.2 0.4 0.6 0.8 1 m/s Measured in installation B


qV
according to ISO5801:
1.4 2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 3 4 6 8 10 20 40 60 80 100 200 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 2200 4 12 -5 0 -7 -7 -6 -9 -15 dB 24 3 5 -5 -5 -4 -7 -13 dB
SX 1400 2 2 -1 -3 -7 -4 -6 -11 -18 dB 11 5 1 -4 -2 -4 -9 -16 dB
SX 800 2 -2 2 -6 -3 -4 -8 -15 -22 dB 5 6 -4 -1 -2 -6 -13 -20 dB
qV opt 2200 3 10 -8 0 -8 -8 -6 -8 -12 dB 20 0 5 -5 -5 -5 -7 -11 dB
qV opt 1400 2 -1 -3 -3 -7 -5 -6 -9 -15 dB 7 2 0 -5 -4 -5 -8 -14 dB
qV opt 800 1 -6 2 -7 -4 -4 -7 -13 -20 dB 0 6 -4 -3 -3 -6 -11 -18 dB
DX 2200 2 0 -15 -5 -12 -10 -5 -6 -9 dB 9 -9 -1 -9 -7 -3 -5 -8 dB
DX 1400 2 -10 -8 -8 -12 -5 -6 -7 -11 dB -3 -3 -5 -10 -3 -4 -6 -10 dB
DX 800 2 -10 -4 -12 -4 -5 -6 -9 -14 dB -5 -1 -10 -2 -4 -5 -8 -14 dB

54
Belt Driven Centrifugal Fans / AT / Technical Data

AT 9/7

Dimensions in mm, subject to change.


AT S-9/7 6.6 kg
380 383
185 188
340
232 119

38
19
9

142.5 142.5
20

253

215
311
255

262
30

412
387
124

120
177
172 224 28
232
258 11 16 131 131
288 123 6
282 300
199 179
AT SC-9/7 8.3 kg

394 385 388


232 59 185 188

6
19

9 142.5 142.5

=
20

215
311
255

262
35

418
324
399

172 224 28
232
=

254 9 12 131 131 = =


274
272 288 36
349

AT AR-9/7 8.3 kg

450 385 388


232 81 185 188
6

8
28

9
7

142.5 142.5

25
215
255

262
311

418
50
324
399

172 224 28
232
=

262 16 11 131 131 = =


274
288 288 36
349

55
Belt Driven Centrifugal Fans / AT / Technical Data

AT 9/9 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 242 mm Impeller weight m 2.9 kg
Number of blades z 43 Density of media r1 1.2 kg/m
Moment of Inertia J 0.034 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N AT AR only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N do not use in this area The AMCA Certified Ratings Seal applies to air performance ratings only.

2500
Pa r
2000

63

53
4.0

67
3.0

41
1500 2.2 7.5

64
1/min W W W
%

59

kW 2300 15 15 28
53

1.5
1.1 100 dB
2100 14 14 25
1000

0.75 1900 13 13 23
800
0.55 1700 11 11 20
600 95
0.37 1500 10 10 18
500
1400 9 9 17
400 0.25 1300 9 9 16
90
1200 8 8 14
0.18
300 1100 7 7 13
0.12
85 1000 7 7 12

200 900 6 6 11

0.06 800 5 5 10
150 80

700 5 5 8
r
P

100 0.03
75
600 4 4 7
A7

80
LW

0.02 60 65
550 4 4 7
70
60
AT SC

AT AR

Normal operation area


DX

AT S

Pb
pF

SX

50
400 500 600 800 1000 1500 2000 3000 4000 5000 6000 8000 10000 m/h

0.2 0.4 0.6 0.8 1 2 m/s Measured in installation B


qV
according to ISO5801:
2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 3 4 6 8 10 20 40 60 80 100 200 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1900 2 0 -5 2 -8 -7 -6 -10 -16 dB 9 1 6 -5 -4 -5 -8 -14 dB
SX 1200 2 -4 4 -5 -5 -5 -6 -12 -20 dB 3 8 -2 -3 -3 -5 -10 -18 dB
SX 700 2 4 0 -4 -3 -4 -8 -16 -23 dB 9 4 -1 -1 -2 -7 -14 -22 dB
qV opt 1900 2 -5 -8 2 -7 -7 -6 -9 -13 dB 3 -3 4 -5 -5 -6 -8 -12 dB
qV opt 1200 1 -8 3 -4 -6 -5 -6 -10 -17 dB -2 6 -2 -4 -4 -5 -9 -16 dB
qV opt 700 1 2 0 -5 -4 -4 -7 -14 -21 dB 6 3 -2 -3 -3 -6 -12 -20 dB
DX 1900 2 -9 -12 -3 -12 -10 -6 -6 -7 dB -2 -8 1 -9 -6 -4 -4 -6 dB
DX 1200 2 -13 -3 -10 -11 -7 -5 -7 -10 dB -7 1 -8 -8 -4 -4 -5 -9 dB
DX 700 2 -5 -6 -11 -7 -5 -6 -8 -14 dB -1 -4 -8 -4 -3 -4 -7 -14 dB

56
Belt Driven Centrifugal Fans / AT / Technical Data

AT 9/9

Dimensions in mm, subject to change.


AT S-9/9 7.9 kg
380 383
185 188
394
298 119

38
19
9

142.5 142.5
20

253

215
311
255

262
30

412
387
124

120
177
172 224 28
298
324 11 16 164 164
354 123 6
348 300
199 179
AT SC-9/9 9.5 kg

460 385 388


298 61 185 188

6
19

9 142.5 142.5

=
20

215
311
255

262
40

418
324
399

172 224 28
298
=

320 9 12 164 164 = =


274
338 354 36
349

AT AR-9/9 9.5 kg

500 385 388


298 81 185 188
6

8
28

9
7

142.5 142.5

25
215
255

262
311

418
50
324
399

172 224 28
298
=

320 16 11 164 164 = =


274
354 354 36
349

57
Belt Driven Centrifugal Fans / AT / Technical Data

AT10/8 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 273 mm Impeller weight m 2.8 kg
Number of blades z 48 Density of media r1 1.2 kg/m
Moment of Inertia J 0.047 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N AT AR only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N do not use in this area The AMCA Certified Ratings Seal applies to air performance ratings only.

65

55
68
7.5

66

42
kW 5.5 1/min W W W

60
2500

52
4.0 2800 19 19 34
Pa 3.0
2000
2.2 2500 17 17 30

1500
1.5 2200 15 15 26

1.1
100 dB 1900 13 13 23
1000
0.75
800
0.55 1600 11 11 19
95
600
0.37 1400 9 9 17
500 1300 9 9 16
0.25 1200 8 8 14
400
90
0.18 1100 7 7 13

300 1000 7 7 12
0.12
85 900 6 6 11

200
800 5 5 10
0.06
150 80 700 5 5 8
r
P

0.03 600 4 4 7
100
75
A7

80 65
LW

60
500 3 3 6
70
Normal operation area
DX

60
SX

AT SC

AT AR
AT S

Pb
pF

50
400 500 600 800 1000 1500 2000 3000 4000 5000 6000 8000 10000 m/h
Measured in
0.2 0.4 0.6 0.8 1 2 m/s
qV installation B
according to ISO5801:
2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 3 4 6 8 10 20 40 60 80 100 200 400 600 800 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1900 3 -9 -8 -2 -8 -6 -5 -9 -14 dB 2 0 4 -4 -3 -3 -7 -12 dB
SX 1200 3 -7 -3 -3 -7 -3 -7 -11 -18 dB 2 3 1 -4 -1 -5 -9 -16 dB
SX 700 2 -3 1 -6 -2 -5 -8 -14 -21 dB 4 5 -3 1 -3 -6 -12 -20 dB
qV opt 1900 2 -12 -11 -3 -7 -7 -5 -8 -12 dB -2 -4 2 -4 -4 -4 -7 -10 dB
qV opt 1200 2 -10 -5 -3 -9 -4 -7 -10 -15 dB -2 0 1 -6 -2 -6 -8 -14 dB
qV opt 700 2 -6 0 -8 -2 -5 -8 -12 -19 dB 0 4 -5 0 -4 -6 -11 -18 dB
DX 1900 2 -12 -12 -7 -11 -10 -6 -6 -7 dB -4 -6 -2 -8 -6 -3 -4 -6 dB
DX 1200 2 -12 -9 -8 -13 -6 -6 -7 -9 dB -5 -4 -5 -9 -4 -4 -5 -8 dB
DX 700 2 -11 -6 -13 -6 -5 -6 -8 -13 dB -5 -3 -9 -4 -3 -5 -6 -13 dB

58
Belt Driven Centrifugal Fans / AT / Technical Data

AT10/8

Dimensions in mm, subject to change.


AT S-10/8 8.3 kg
425 428
203 206
355
265 136

38
19
9

157
20

287

249
340
284

289
35

469
443
157

132

132
198
172 224 28
265
291 11 16 147.5 147.5
321 135 6
315 340
227 197
AT SC-10/8 9.8 kg

425 431 434


265 60 203 206

6
19

=
157
20

249
340
284

289
40

475
390
455
157

172 224 28
265
=

9 12 147.5 147.5 = =
287 330
305 321 36
395

AT AR-10/8 9.8 kg

480 431 334


265 79.5 203 206
6

8
28

9
7

=
157

25
249
284

289
340

475
50
365
455
157

172 224 28
265
=

16 11 147.5 147.5 = =
295 305
321 321 36
395

59
Belt Driven Centrifugal Fans / AT / Technical Data

AT10/10 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 273 mm Impeller weight m 3.5 kg
Number of blades z 48 Density of media r1 1.2 kg/m
Moment of Inertia J 0.055 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N AT AR only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N do not use in this area The AMCA Certified Ratings Seal applies to air performance ratings only.

2500 r
Pa

56
65
2000

68

43
7.5

66
5.5 1/min W W W
%

62
4.0
57

3.0 2200 14 14 26
1500 2.2
2000 13 13 24
kW
1.5
100 dB 1800 12 12 22
1000
1.1
800 1600 11 11 19
0.75
95
1400 9 9 17
600 0.55
1300 9 9 16
500
0.37 1200 8 8 14
400 90
1100 7 7 13
0.25
1000 7 7 12
300
0.18
85 900 6 6 11

0.12 800 5 5 10
200

700 5 5 8
r

80
P

150
A7

0.06
LW

65 70 600 4 4 7
75
100

80 Normal operation area


DX
SX

60
AT SC

AT AR
AT S

Pb
pF

50
600 800 1000 1500 2000 3000 4000 5000 6000 8000 10000 15000 m/h

0.2 0.4 0.6 0.8 1 2 3 4 m/s


qV Measured in installation B
according to ISO5801:
2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

3 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1800 3 0 -4 1 -7 -7 -7 -9 -14 dB 9 3 5 -3 -4 -5 -7 -12 dB
SX 1200 2 -1 0 0 -7 -5 -6 -10 -17 dB 8 5 4 -4 -4 -5 -8 -15 dB
SX 700 2 -1 3 -4 -4 -4 -7 -13 -21 dB 5 7 -1 -2 -3 -6 -12 -20 dB
qV opt 1800 2 -4 -8 -1 -8 -7 -6 -8 -11 dB 4 -2 3 -5 -4 -5 -6 -10 dB
qV opt 1200 2 -6 -3 -2 -7 -6 -6 -9 -14 dB 2 2 1 -4 -4 -5 -7 -13 dB
qV opt 700 2 -4 0 -6 -4 -4 -7 -11 -19 dB 1 4 -3 -3 -3 -5 -10 -18 dB
DX 1800 3 -1 -5 -3 -9 -8 -7 -7 -8 dB 7 1 1 -5 -5 -4 -5 -7 dB
DX 1200 2 -2 -4 -4 -9 -7 -6 -7 -10 dB 5 0 -1 -6 -4 -4 -6 -8 dB
DX 700 2 -5 -2 -9 -7 -6 -6 -8 -13 dB 0 1 -5 -4 -4 -4 -7 -13 dB

60
Belt Driven Centrifugal Fans / AT / Technical Data

AT10/10

Dimensions in mm, subject to change.


AT S-10/10 9.3 kg
425 428
203 206
420
331 136

38
19
9

157
20

287

249
340
284

289
35

469
443
157

132

132
198
172 224 28
331
357 11 16 180.5 180.5
387 135 6
381 340
227 197
AT SC-10/10 11 kg

490 431 434


331 59 203 206

6
19

=
157
20

249
340
284

289
40

475
390
455
157

172 224 28
331
=

353 9 12 180.5 180.5 = =


330
371 387 36
395

AT AR-10/10 11 kg

540 431 434


331 76.5 203 206
6

8
28

9
7

=
157

25
249
284

289
340

475
50
365
455
157

172 224 28
331
=

361 16 11 180.5 180.5 = =


305
387 387 36
395

61
Belt Driven Centrifugal Fans / AT / Technical Data

AT12/9 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 322 mm Impeller weight m 4.4 kg
Number of blades z 43 Density of media r1 1.2 kg/m
Moment of Inertia J 0.097 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N AT AR only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N do not use in this area The AMCA Certified Ratings Seal applies to air performance ratings only.

11

64

53
2500

68
7.5 1/min W W W
Pa 5.5

40
64
kW 4.0
%
2000 26 26 33

57
2200
49

3.0
110 dB 2000 24 24 30
1500 2.2
1800 22 22 27
1.5
105 1600 19 19 24
1000 1.1

800 1400 17 17 21
0.75
1300 16 16 20
100
600 0.55 1200 14 14 18

500 1100 13 13 17
0.37
400 1000 12 12 15
95
0.25
900 11 11 14
300
r
P

0.18
800 10 10 12
90
0.12
200 700 8 8 11

150 600 7 7 9
0.06 85
A7
LW

70 75
65
100 500 6 6 8
80
Normal operation area
DX

80
SX

60
AT SC

AT AR
AT S

Pb
pF

50
600 800 1000 1500 2000 3000 4000 5000 6000 8000 10000 15000 m/h

0.2 0.4 0.6 0.8 1 2 3 4 m/s


qV Measured in
installation B
2 3 4 5 6 7 8 9 10 14 20 30 40 50m/s according to ISO5801:
v2

2 3 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1800 2 1 -2 0 -8 -6 -6 -9 -13 dB 10 4 3 -6 -4 -4 -7 -10 dB
SX 1200 2 0 2 -5 -7 -4 -7 -10 -16 dB 7 6 -3 -5 -3 -5 -7 -14 dB
SX 700 2 3 -1 -5 -3 -5 -7 -13 -18 dB 7 2 -3 -1 -3 -5 -10 -16 dB
qV opt 1800 1 0 -7 -5 -9 -6 -5 -8 -11 dB 8 -2 -2 -7 -5 -5 -6 -9 dB
qV opt 1200 1 -1 -5 -8 -8 -4 -6 -9 -14 dB 6 -1 -6 -5 -4 -5 -7 -12 dB
qV opt 700 1 -4 -5 -6 -3 -5 -7 -11 -17 dB 0 -3 -4 -2 -4 -5 -10 -16 dB
DX 1800 2 -10 -10 -7 -12 -9 -4 -7 -10 dB -4 -5 -4 -9 -6 -2 -5 -8 dB
DX 1200 2 -10 -6 -10 -12 -5 -5 -8 -11 dB -5 -3 -8 -8 -3 -4 -6 -10 dB
DX 700 2 -6 -7 -11 -5 -4 -7 -10 -13 dB -3 -5 -8 -3 -2 -5 -8 -13 dB

62
Belt Driven Centrifugal Fans / AT / Technical Data

AT12/9

Dimensions in mm, subject to change.


AT S-12/9 12.7 kg
491 494
230 233
420
309 161

38
8

28
7
9

182
25

332

294
390
334

341
35

546
521
182

153
153
232
172 224 28
309
335 11 16 169.5 169.5
365 161 6
359 408
266 224
AT SC-12/9 16 kg

495 497 500


309 65 230 233

6
8
28
7

=
182
25

294
390
334

341
45

552
443
533
182

172 224 28
309
=

339 11 16 169.5 169.5 = =


371
365 365 36
461

AT AR-12/9 16 kg

560 497 500


309 97.5 230 233
6

8
33

9
7

=
182

30
295
334

341
390

552
60
443
533
182

172 224 28
309
=

339 16 11 169.5 169.5 = =


371
365 365 36
461

63
Belt Driven Centrifugal Fans / AT / Technical Data

AT12/12 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 322 mm Impeller weight m 5.2 kg
Number of blades z 43 Density of media r1 1.2 kg/m
Moment of Inertia J 0.118 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N AT AR only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N do not use in this area The AMCA Certified Ratings Seal applies to air performance ratings only.

Pa
r
2000

64

54
67

42
7.5 11
1500 5.5

64
1/min W W W
%

58

4.0
50

1700 20 20 26
3.0
1600 19 19 24
2.2
1000 kW 1500 18 18 23
1.5 100 dB 1400 17 17 21
800
1.1 1300 16 16 20

1200 14 14 18
600
0.75 95 1100 13 13 17
500
0.55 1000 12 12 15
400
0.37 900 11 11 14
90
300
800 10 10 12
0.25

0.18 85 700 8 8 11
200

0.12 600 7 7 9
150
r
P

80
A7

70
LW

65 75 500 6 6 8
100 0.06
DX

80 Normal operation area


SX

60
AT SC

AT AR
AT S

Pb
pF

50
800 1000 1500 2000 3000 4000 5000 6000 8000 10000 15000 m/h

0.4 0.6 0.8 1 2 3 4 5 m/s


qV Measured in installation B
according to ISO5801:
2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

2 3 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1400 2 -6 1 2 -7 -7 -7 -9 -14 dB 2 6 6 -5 -6 -5 -7 -13 dB
SX 900 2 -2 5 -4 -6 -5 -7 -10 -18 dB 4 9 -1 -4 -4 -5 -8 -17 dB
SX 600 2 5 3 -5 -4 -4 -7 -14 -21 dB 10 7 -2 -3 -3 -5 -12 -20 dB
qV opt 1400 2 -3 -2 -1 -7 -7 -6 -8 -13 dB 4 3 3 -5 -5 -5 -7 -11 dB
qV opt 900 2 -2 2 -5 -6 -5 -6 -9 -17 dB 3 5 -2 -4 -4 -5 -8 -16 dB
qV opt 600 1 2 0 -5 -5 -4 -7 -12 -20 dB 6 3 -3 -3 -3 -6 -11 -20 dB
DX 1400 2 -4 -4 -3 -9 -8 -6 -7 -10 dB 2 1 0 -5 -5 -4 -6 -9 dB
DX 900 2 -4 -2 -6 -8 -6 -6 -8 -12 dB 2 2 -3 -4 -4 -4 -7 -11 dB
DX 600 2 -2 -3 -8 -6 -4 -7 -10 -14 dB 2 1 -4 -3 -3 -5 -8 -15 dB

64
Belt Driven Centrifugal Fans / AT / Technical Data

AT12/12

Dimensions in mm, subject to change.


AT S-12/12 15.2 kg
491 494
230 233
510
395 161

38
8

28
7
9

182
25

332

294
390
334

341
35

546
521
182

153
153
232
172 224 28
395
421 11 16 212.5 212.5
451 161 6
445 408
266 224
AT SC-12/12 18.4 kg

585 497 500


395 67 230 233

6
8
28
7

=
182
25

294
390
334

341
45

552
443
533
182

172 224 28
395
=

425 11 16 212.5 212.5 = =


371
451 451 36
461

AT AR-12/12 18.4 kg

620 497 500


395 85 230 233
6

8
33

9
7

=
182

30
294
334

341
390

552
60
443
533
182

172 224 28
395
=

425 16 11 212.5 212.5 = =


371
451 451 36
461

65
Belt Driven Centrifugal Fans / AT / Technical Data

AT15/11 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 381 mm Impeller weight m 6.2 kg
Number of blades z 51 Density of media r1 1.2 kg/m
Moment of Inertia J 0.186 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N AT AR only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N do not use in this area The AMCA Certified Ratings Seal applies to air performance ratings only.

58
67
70
1/min W W W

67
Pa

63
%
2200 26 26 33

58
3500 kW

54
15
3000 11 2000 24 24 30

2500 7.5 1800 22 22 27

2000 5.5 1600 19 19 24


100 dB
4.0
1500 1400 17 17 21
3.0
95 14 14 18
2.2 1200
1000
1100 13 13 17
800 1.5
1000 12 12 15
1.1 90
600 900 11 11 14

500 0.75
800 10 10 12
0.55 85
400
700 8 8 11
0.37
300
80 600 7 7 9
0.25

200
r
P

500 6 6 8
A7

75
LW

150 0.12 450 5 5 7


70
65
DX

100
Normal operation
AT SC

AT AR
AT S

area
SX

Pb
pF

80
1500 2000 3000 4000 5000 6000 8000 10000 15000 20000 m/h

0.3 0.4 0.6 0.8 1 2 3 4 5 6 7 m/s


qV Measured in installation B
according to ISO5801:
2 3 4 5 6 7 8 9 10 14 20 30 40 50 m/s
v2

3 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1600 3 -6 2 0 -5 -6 -8 -9 -12 dB 3 8 4 -2 -4 -6 -7 -10 dB
SX 1000 3 -1 4 -3 -4 -6 -7 -9 -15 dB 6 8 1 -2 -4 -5 -7 -13 dB
SX 600 2 6 0 -2 -3 -6 -7 -12 -18 dB 11 3 1 -1 -4 -5 -10 -17 dB
qV opt 1600 2 -6 2 -2 -5 -6 -8 -8 -11 dB 1 7 1 -3 -5 -7 -6 -9 dB
qV opt 1000 2 -2 1 -3 -5 -6 -7 -9 -13 dB 4 5 0 -3 -6 -5 -7 -12 dB
qV opt 600 1 4 -1 -3 -4 -5 -6 -11 -17 dB 9 2 -1 -4 -4 -5 -9 -16 dB
DX 1600 2 -7 -5 -5 -8 -8 -7 -6 -8 dB -1 0 -1 -5 -5 -5 -5 -7 dB
DX 1000 2 -6 -4 -7 -8 -7 -6 -7 -10 dB 0 0 -5 -5 -5 -4 -6 -9 dB
DX 600 2 -3 -6 -7 -6 -6 -6 -8 -12 dB 1 -3 -4 -4 -4 -4 -7 -12 dB

66
Belt Driven Centrifugal Fans / AT / Technical Data

AT15/11

Dimensions in mm, subject to change.


AT S-15/11 17.7 kg
569 572
264 267
510
373 197

38
8

28
7
9

213.5 213.5
25

380

342
453
397

404
35

634
609
211

200
272
172 224 28
373
399 11 16 201.5 201.5
429 201 6
423 495
309 258
AT SC-15/11 20.9 kg

585 575 578


373 78 264 267

6
8
28
7

9 213.5 213.5

=
25

342
453
397

404
45

640
531
621

172 224 28
373
=

403 11 16 201.5 201.5 = =


449
429 429 36
539

AT AR-15/11 20.9 kg

620 575 578


373 96 264 267
6

8
33

9
7

213.5 213.5

30
342
397

404
453

640
60
531
621

172 224 28
373
=

403 16 11 201.5 201.5 = =


449
429 429 36
539

67
Belt Driven Centrifugal Fans / AT / Technical Data

AT15/15 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 381 mm Impeller weight m 7.5 kg
Number of blades z 51 Density of media r1 1.2 kg/m
Moment of Inertia J 0.233 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N AT AR only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N do not use in this area The AMCA Certified Ratings Seal applies to air performance ratings only.

2500
Pa
2000
r
1500

67

58
7.5 11

70

47
67 5.5
4.0 1/min W W W
%

60

kW 3.0 1300 16 16 20
54

1000 2.2
1200 14 14 18
100 dB
800 1100 13 13 17
1.5

1.1 1000 12 12 15
600
95
500 900 11 11 14
0.75

400 800 10 10 12
0.55
90
0.37 700 8 8 11
300

0.25 600 7 7 9
85
200
0.18
500 6 6 8
150
0.12
80
r

450 5 5 7
P

A7

0.09
LW

100 65 70 400 5 5 6
75

80
DX

Normal operation area


SX

60
AT SC

AT AR
AT S

Pb
pF

50
1500 2000 3000 4000 5000 6000 8000 10000 15000 20000 m/h

0.3 0.4 0.6 0.8 1 2 3 4 5 6 7 m/s


qV Measured in installation B
according to ISO5801:
2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

2 3 4 6 8 10 20 40 60 80 100 200 400 600 800 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1100 2 -4 2 -3 -3 -7 -8 -9 -14 dB 2 6 0 -1 -6 -6 -7 -12 dB
SX 800 2 1 2 -2 -5 -6 -7 -10 -16 dB 6 5 1 -4 -5 -5 -8 -15 dB
SX 500 1 5 -1 -1 -4 -5 -7 -12 -19 dB 8 2 1 -4 -4 -5 -11 -19 dB
qV opt 1100 2 -8 -1 -5 -4 -7 -7 -8 -12 dB -2 2 -2 -1 -5 -6 -7 -11 dB
qV opt 800 2 -3 -1 -3 -5 -6 -6 -9 -14 dB 2 2 0 -3 -5 -5 -8 -13 dB
qV opt 500 2 1 -3 -2 -5 -5 -6 -11 -17 dB 4 0 1 -4 -4 -5 -10 -17 dB
DX 1100 2 -4 -2 -6 -6 -7 -7 -7 -10 dB 2 2 -3 -2 -5 -5 -6 -9 dB
DX 800 2 -1 -2 -5 -7 -7 -6 -8 -11 dB 3 1 -3 -4 -4 -4 -6 -11 dB
DX 500 2 0 -6 -4 -7 -5 -6 -9 -14 dB 3 -3 -1 -4 -3 -5 -8 -14 dB

68
Belt Driven Centrifugal Fans / AT / Technical Data

AT15/15

Dimensions in mm, subject to change.


AT S-15/15 20.6 kg
569 572
264 267
608
471 197

38
8

28
7
9

213.5 213.5
25

380

342
453
397

404
40

634
609
211

200
272
172 224 28
471
497 11 16 250.5 250.5
527 201 6
521 495
309 258
AT SC-15/15 24.5 kg

685 575 578


471 79 264 267

6
8
28
7

9 213.5 213.5

=
25

342
453
397

404
55

640
531
621

172 224 28
471
=

11 16 250.5 250.5 = =
501 449
527 527 36
539

AT AR-15/15 24.5 kg

700 575 578


471 87 264 267
6

8
33

9
7

213.5 213.5

30
342
397

404
453

640
60
531
621

172 224 28
471
=

16 11 250.5 250.5 = =
501 449
527 527 36
539

69
Belt Driven Centrifugal Fans / AT / Technical Data

AT18/13 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 459 mm Impeller weight m 10.5 kg
Number of blades z 48 Density of media r1 1.2 kg/m
Moment of Inertia J 0.463 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N AT AR only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N do not use in this area The AMCA Certified Ratings Seal applies to air performance ratings only.

2500 r
Pa

61
69
2000 15

72

48
7.5 11

71
1/min W W W
%

67
5.5
62

kW 1300 16 16 22
1500
4.0
1200 14 14 20
3.0 1100 13 13 19
1000
2.2 1000 12 12 17
800 100 dB
1.5 900 11 11 15

600 1.1 800 10 10 14

500 95
0.75 700 8 8 12
400
0.55
600 7 7 10
300 90
0.37

500 6 6 8
0.25
200
85
0.18
r
P

150 400 5 5 7
0.12
80
350 4 4 6
100
A7
LW

65 70 4 4 5
60 300
80 75
DX

Normal operation area


SX

60
AT SC

AT AR
AT S

Pb
pF

50
1500 2000 3000 4000 5000 6000 8000 10000 15000 20000 30000 m/h

0.4 0.6 0.8 1 2 3 4 5 6 7 8 10 m/s


qV Measured in installation B
according to ISO5801:
2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

3 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1100 3 1 6 0 -7 -6 -9 -9 -14 dB 8 11 3 -5 -4 -6 -6 -11 dB
SX 700 2 7 5 -4 -4 -7 -7 -10 -17 dB 13 9 -2 -3 -5 -4 -7 -15 dB
SX 400 2 8 -1 -3 -4 -5 -7 -13 -21 dB 12 1 -1 -2 -3 -4 -12 -21 dB
qV opt 1100 2 -3 1 1 -7 -6 -8 -8 -12 dB 5 6 4 -4 -5 -7 -6 -11 dB
qV opt 700 2 2 3 -5 -5 -7 -6 -9 -15 dB 8 7 -2 -3 -6 -4 -7 -14 dB
qV opt 400 2 6 -2 -3 -5 -5 -6 -13 -19 dB 10 1 -2 -4 -3 -5 -11 -20 dB
DX 1100 2 -8 -3 -7 -10 -5 -7 -6 -10 dB -2 2 -3 -6 -3 -6 -5 -9 dB
DX 700 2 -3 -4 -9 -5 -7 -6 -8 -12 dB 2 -1 -6 -2 -5 -4 -7 -12 dB
DX 400 2 -2 -8 -4 -6 -5 -6 -10 -15 dB 2 -4 -1 -4 -3 -5 -10 -16 dB

70
Belt Driven Centrifugal Fans / AT / Technical Data

AT18/13

Dimensions in mm, subject to change.


AT S-18/13 27 kg
684 687
314 317
567
430 262

42
8

28
7
9

250.5 250.5
25

457

415
527
471

478
40

764
739
283

288
340
172 224 28
430
456 11 16 230 230
486 278 6
480 608
376 307
AT SC-18/13 33 kg

666 690 693


430 80 314 317

6
8
28
7

9 250.5 250.5

=
25

415
527
471

478
55

770
641
751

172 224 28
430
=

470 11 16 230 230 = =


544
506 486 36
654

AT AR-18/13 33 kg

690 690 643


430 120 314 317
6

10
38

9
8

250.5 250.5

35
415
471

478
527

770
60
641
751

172 224 28
430
=

470 18 13 230 230 = =


544
506 486 41
654

71
Belt Driven Centrifugal Fans / AT / Technical Data

AT18/18 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 459 mm Impeller weight m 15.2 kg
Number of blades z 48 Density of media r1 1.2 kg/m
Moment of Inertia J 0.568 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N AT AR only Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
N do not use in this area The AMCA Certified Ratings Seal applies to air performance ratings only.

2500
Pa
2000 r

57
15

67
70

44
1500 7.5 11 1/min W W W
68
62
%

kW 5.5 1200 14 14 20
55

4.0
1100 13 13 19
1000
3.0
1000 12 12 17
800 2.2
900 11 11 15

600 1.5
800 10 10 14
100 dB
500 1.1
700 8 8 12
400
0.75
95 600 7 7 10
300 0.55
550 7 7 9
0.37
500 6 6 8
200 90
0.25 450 5 5 8

150 0.18 400 5 5 7


r
P

85

0.12 350 4 4 6
100
A7
LW

65 70 75 80
80 300 4 4 5
60
DX

60 Normal operation area


AT SC

AT AR
SX

AT S

Pb
pF

50
2000 3000 4000 5000 6000 8000 10000 15000 20000 30000 m/h

0.6 0.8 1 2 3 4 5 6 7 8 9 10 m/s


qV Measured in installation B
according to ISO5801:
2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

2 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1000 2 2 5 -1 -5 -6 -8 -10 -15 dB 8 10 3 -2 -4 -7 -8 -13 dB
SX 700 2 6 4 -2 -4 -6 -8 -10 -17 dB 12 8 2 -2 -4 -6 -9 -16 dB
SX 400 2 7 1 -2 -3 -5 -7 -13 -21 dB 11 4 0 -2 -4 -6 -12 -21 dB
qV opt 1000 2 -3 0 -2 -5 -6 -7 -8 -13 dB 3 4 1 -2 -5 -6 -7 -12 dB
qV opt 700 2 0 0 -3 -4 -6 -7 -9 -16 dB 5 3 0 -3 -5 -5 -8 -15 dB
qV opt 400 1 2 -1 -3 -4 -5 -6 -13 -20 dB 5 2 -1 -3 -3 -5 -12 -21 dB
DX 1000 2 -5 -6 -8 -7 -6 -7 -6 -9 dB 1 -2 -4 -4 -4 -5 -5 -8 dB
DX 700 2 -5 -7 -8 -6 -7 -6 -7 -11 dB 0 -3 -4 -3 -5 -5 -6 -11 dB
DX 400 1 -6 -7 -5 -6 -5 -6 -9 -16 dB -2 -4 -2 -4 -4 -4 -9 -17 dB

72
Belt Driven Centrifugal Fans / AT / Technical Data

AT18/18

Dimensions in mm, subject to change.


AT S-18/18 32.5 kg
684 687
314 317
694
557 262

42
8

28
7
9

250.5 250.5
25

457

415
527
471

478
40

764
739
283

288
340
172 224 28
557
583 11 16 293.5 293.5
613 278 6
607 608
376 307
AT SC-18/18 38.2 kg

790 690 693


557 78 314 317

6
8
28
7

9 250.5 250.5

=
25

415
527
471

478
55

770
641
751

172 224 28
557
=

597 11 16 293.5 293.5 = =


544
633 613 36
654

AT AR-18/18 38.2 kg

875 690 693


557 121 314 317
6

10
38

9
8

250.5 250.5

35
415
471

478
527

770
60
641
751

172 224 28
557
=

597 18 13 293.5 293.5 = =


544
633 613 41
654

73
Belt Driven Centrifugal Fans / AT / Technical Data

AT20/15 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 516 mm Impeller weight m 17.7 kg
Number of blades z 42 Density of media r1 1.2 kg/m
Moment of Inertia J 1.026 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N do not use in this area Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to air performance ratings only.

67
2500 22

70

57
15

68
Pa 1/min W

64
11

58

44
2000 kW
7.5 1400 24
1300 22
1500 5.5
1200 20
105 dB
4.0
1100 19
1000 3.0
1000 17
100
800 2.2
900 15

600 1.5 800 14


95
500 1.1
700 12
400 0.75
90
600 10
300

0.37 500 8
85
200

150 0.18 80 400 7


r
P

350 6
100
0.09 75
300 5
80
A7

60
LW

65 70
60 250 4
50 Normal operation area
AT TIC
SX

DX

Pb
pF

40
2000 3000 4000 5000 6000 8000 10000 15000 20000 30000 m/h

0.6 0.8 1 2 3 4 5 6 7 8 9 10 m/s


qV Measured in installation B
according to ISO5801:
2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 4 6 8 10 20 40 60 80 100 200 400 600 800 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1100 3 3 4 3 -4 -7 -10 -11 -14 dB 10 10 6 -1 -5 -8 -9 -12 dB
SX 700 3 6 6 -1 -4 -7 -8 -11 -16 dB 12 10 2 -2 -4 -6 -8 -14 dB
SX 400 2 9 1 -1 -4 -5 -8 -12 -18 dB 13 4 2 -2 -3 -5 -11 -18 dB
qV opt 1100 2 0 1 0 -4 -6 -9 -10 -13 dB 5 6 4 -1 -5 -8 -9 -12 dB
qV opt 700 2 2 4 -1 -3 -7 -8 -10 -15 dB 7 7 1 -2 -5 -6 -9 -14 dB
qV opt 400 2 6 1 0 -4 -5 -8 -12 -17 dB 10 3 2 -3 -4 -6 -11 -17 dB
DX 1100 2 -1 -4 -4 -4 -5 -8 -10 -13 dB 4 1 0 -1 -3 -6 -8 -11 dB
DX 700 2 -2 -1 -3 -3 -6 -7 -11 -14 dB 3 2 0 0 -4 -6 -9 -14 dB
DX 400 2 1 -2 0 -4 -5 -8 -11 -16 dB 4 1 2 -2 -4 -7 -11 -18 dB

74
Belt Driven Centrifugal Fans / AT / Technical Data

AT20/15

Dimensions in mm, subject to change.


AT TIC-20/15 71 kg

770 830 833


502 96 369 372
10

52
38
8

=
11

275 275
35

520
622

698

629
65

662

950
827
967
38
200 200

=
542 13 18 502 = =
632
578 542 58
772
578

75
Belt Driven Centrifugal Fans / AT / Technical Data

AT20/20 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 516 mm Impeller weight m 20 kg
Number of blades z 42 Density of media r1 1.2 kg/m
Moment of Inertia J 1.175 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N do not use in this area Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to air performance ratings only.

r
2500

65
68

58
Pa 22 1/min W
15

65

48
%

59
2000

54
11 1400 24

kW 105 dB 1300 22
1500 7.5
1200 20

5.5 1100 19

1000 4.0 100 1000 17

800 3.0 900 15

2.2
95 800 14
600

500 1.5
700 12
1.1 90
400
600 10
0.75
300
85
0.55
500 8

200 0.37
80
r
P

400 7
150

0.18 350 6
75
100
300 5
80 0.09 70
A7
LW

60 250 4
60
65
50 Normal operation area
AT TIC
DX
SX

Pb
pF

40
2000 3000 4000 5000 6000 8000 10000 15000 20000 30000 40000 m/h

1 2 3 4 5 6 7 8 9 10 14 m/s Measured in installation B


qV
according to ISO5801:
1.4 2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 4 6 8 10 20 40 60 80 100 200 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1100 3 8 2 5 -4 -9 -12 -14 -18 dB 13 8 9 -1 -8 -11 -12 -16 dB
SX 700 3 11 8 -1 -2 -9 -10 -13 -19 dB 17 13 2 0 -8 -8 -11 -18 dB
SX 400 2 12 4 2 -5 -6 -8 -14 -20 dB 16 7 4 -4 -4 -7 -13 -21 dB
qV opt 1100 3 3 -1 5 -4 -8 -11 -12 -17 dB 8 4 9 -1 -6 -10 -11 -15 dB
qV opt 700 2 6 7 -1 -2 -8 -9 -12 -18 dB 12 12 2 0 -7 -8 -11 -17 dB
qV opt 400 2 10 3 2 -4 -6 -8 -13 -20 dB 15 6 4 -3 -5 -7 -12 -21 dB
DX 1100 3 -2 -5 1 -3 -6 -9 -10 -14 dB 1 1 5 0 -4 -7 -8 -14 dB
DX 700 2 0 2 -2 -3 -6 -7 -11 -16 dB 5 7 2 0 -4 -6 -10 -15 dB
DX 400 2 4 0 0 -4 -5 -8 -12 -18 dB 9 4 3 -2 -4 -7 -12 -19 dB

76
Belt Driven Centrifugal Fans / AT / Technical Data

AT20/20

Dimensions in mm, subject to change.


AT TIC-20/20 78 kg

900 830 833


630 97 369 372
10

52
38
8

=
11

275 275
35

520
622

698

629
65

662

950
827
967
38
275 275

=
670 13 18 630 = =
632
706 670 58
772
706

77
Belt Driven Centrifugal Fans / AT / Technical Data

AT22/15 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 566 mm Impeller weight m 20 kg
Number of blades z 48 Density of media r1 1.2 kg/m
Moment of Inertia J 1.370 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N do not use in this area Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to air performance ratings only.

r
30

66
70
22

54
67
2500 15

60
%
52
Pa 11 1/min W

39
2000 1400 24
kW
7.5 1300 22
1500 110 dB
5.5 1200 20

4.0 1100 19

1000 1000 17
3.0 105

800 900 15
2.2

800 14
600 1.5 100

500 1.1 700 12

400
0.75 95
600 10

300

90 500 8
0.37
200
r
P

85 400 7
150 0.18

100 80
0.09
300 5
80
65
A7

70 75
LW

250 4
AT TIC

60 Normal operation area


SX

Pb
DX
pF

50
2000 3000 4000 5000 6000 8000 10000 15000 20000 30000 40000 m/h

0.6 0.8 1 2 3 4 5 6 7 8 9 10 m/s Measured in


qV
installation B
1.4 2 3 4 5 6 7 8 9 10 14 20 30 40 m/s according to ISO5801:
v2

2 4 6 8 10 20 40 60 80 100 200 400 600 8001000 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1100 3 2 3 3 -6 -6 -9 -11 -15 dB 8 9 7 -3 -4 -6 -9 -13 dB
SX 700 3 4 6 -3 -3 -6 -8 -12 -17 dB 11 11 0 -1 -4 -6 -9 -15 dB
SX 400 2 9 1 -1 -3 -5 -9 -13 -18 dB 14 4 1 -1 -3 -6 -11 -18 dB
qV opt 1100 2 0 0 1 -5 -5 -9 -11 -14 dB 5 6 5 -2 -4 -7 -9 -12 dB
qV opt 700 2 2 3 -3 -2 -6 -8 -11 -15 dB 8 8 0 -1 -5 -7 -9 -14 dB
qV opt 400 2 6 0 0 -3 -6 -8 -12 -16 dB 11 3 1 -2 -4 -7 -11 -17 dB
DX 1100 2 -5 -4 -2 -6 -4 -8 -9 -13 dB 11 3 1 -2 -4 -7 -11 -17 dB
DX 700 2 -4 0 -5 -2 -6 -7 -10 -13 dB 2 4 -2 0 -4 -6 -9 -12 dB
DX 400 2 2 -3 -1 -3 -6 -8 -10 -14 dB 7 1 2 -1 -4 -7 -10 -16 dB

78
Belt Driven Centrifugal Fans / AT / Technical Data

AT22/15

Dimensions in mm, subject to change.


AT TIC-22/15 73 kg

782 905 908


514 96 398 401
10

52
38
8

=
11

300 300
35

573
688

764

695
728
65

1041
1058
918
38
225 225

=
554 13 18 514 = =
707
590 554 58
847
590

79
Belt Driven Centrifugal Fans / AT / Technical Data

AT22/22 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 566 mm Impeller weight m 26 kg
Number of blades z 48 Density of media r1 1.2 kg/m
Moment of Inertia J 1.729 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N do not use in this area Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to air performance ratings only.

2500

64
30

69
67
%
Pa 22

50
62
15
2000 kW 57
11

34
1/min W
1500 1300 22
7.5
1200 20
5.5 110 dB
1100 19
1000
4.0 1000 17
800
3.0 105 900 15

600 2.2
800 14
500 100
1.5 700 12
400
1.1
10
600
300 0.75 95

0.55
500 9
200 90

150
0.25 400 7
85
r
P

350 6
100
0.12 80
80 300 5
60 65
70
A7
SX

AT TIC

60 Normal operation area


LW

75
250 4
Pb
pF

DX

50
3000 4000 5000 6000 8000 10000 15000 20000 30000 40000 60000 m/h

0.8 1 2 3 4 5 6 7 8 9 10 14 m/s Measured in installation B


qV
according to ISO5801:
2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 4 6 8 10 20 40 60 80 100 200 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1100 3 3 3 5 -4 -9 -13 -14 -17 dB 7 9 9 -1 -8 -11 -12 -16 dB
SX 700 3 6 9 1 -4 -9 -10 -13 -18 dB 12 14 4 -2 -7 -8 -11 -17 dB
SX 400 2 13 6 1 -5 -6 -9 -13 -22 dB 18 9 3 -3 -5 -7 -12 -22 dB
qV opt 1100 3 1 2 5 -4 -8 -13 -14 -17 dB 5 7 9 -1 -7 -11 -12 -16 dB
qV opt 700 3 4 9 1 -3 -8 -10 -13 -18 dB 10 13 4 -1 -7 -9 -11 -17 dB
qV opt 400 2 13 6 1 -4 -6 -8 -13 -21 dB 17 9 3 -3 -5 -7 -12 -22 dB
DX 1100 3 -1 0 3 -7 -6 -8 -10 -13 dB 3 5 7 -2 -3 -6 -8 -12 dB
DX 700 3 1 5 -4 -4 -6 -7 -10 -14 dB 6 10 0 -1 -4 -5 -9 -14 dB
DX 400 2 8 -1 -2 -4 -5 -8 -11 -17 dB 12 3 1 -2 -3 -6 -10 -18 dB

80
Belt Driven Centrifugal Fans / AT / Technical Data

AT22/22

Dimensions in mm, subject to change.


AT TIC-22/22 82.5 kg

960 905 908


692 96 398 401
10

52
38
8

=
11

300 300
35

573
688

764

695
728
65

1041
1058
918
38
300 300

=
732 13 18 692 = =
707
768 732 58
847
768

81
Belt Driven Centrifugal Fans / AT / Technical Data

AT25/20 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 636 mm Impeller weight m 29 kg
Number of blades z 56 Density of media r1 1.2 kg/m
Moment of Inertia J 2.475 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N do not use in this area Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to air performance ratings only.

r
2500

66
71
Pa 22 30

66

54
%

57
2000 kW

47
15

40
11 1/min W
1100 23
1500
7.5 1000 21

5.5 19
900
1000 105 dB
4.0
800 800 17
3.0
700 15
600 2.2 100
500
1.5 600 13
400 95
1.1
500 11
300 0.75

0.55 90

200 400 8

85 350 7
150
0.25
r
P

300 6
80
100
0.12
80 250 5

75
60
60
65
A7

50 200 4
LW

Normal operation area


AT TIC

70
SX

DX

Pb
pF

40
2000 3000 4000 5000 6000 8000 10000 15000 20000 30000 40000 50000 m/h

1 2 3 4 5 6 7 8 9 10 14 m/s Measured in
qV
installation B
1.4 2 3 4 5 6 7 8 9 10 14 20 30 m/s according to ISO5801:
v2

0.8 1 2 4 6 8 10 20 40 60 80 100 200 400 600 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point 1/min dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
SX 900 4 5 8 2 -4 -7 -11 -14 -15 dB 10 14 6 -1 -5 -9 -11 -13 dB
SX 600 3 7 9 1 -4 -7 -10 -12 -17 dB 14 13 4 -2 -5 -8 -10 -15 dB
SX 300 2 13 4 0 -3 -6 -8 -13 -21 dB 17 8 2 -1 -4 -6 -11 -22 dB
qV opt 900 2 2 5 1 -5 -5 -10 -13 -16 dB 6 10 4 -3 -4 -9 -11 -15 dB
qV opt 600 2 4 7 -1 -2 -7 -9 -12 -17 dB 9 11 2 -2 -6 -8 -11 -17 dB
qV opt 300 1 10 3 1 -3 -6 -9 -14 -21 dB 14 5 2 -2 -5 -7 -13 -23 dB
DX 900 3 -2 0 -2 -6 -4 -8 -10 -14 dB 2 5 2 -2 -2 -6 -9 -13 dB
DX 600 2 -1 1 -4 -3 -5 -8 -11 -15 dB 5 5 0 0 -4 -6 -10 -15 dB
DX 300 2 4 -1 0 -3 -5 -8 -12 -18 dB 8 3 2 -1 -4 -7 -12 -20 dB

82
Belt Driven Centrifugal Fans / AT / Technical Data

AT25/20

Dimensions in mm, subject to change.


AT TIC-25/20 93 kg

930 1010 1013


664 95 438 441
12

52
43
8

=
11

350 350
40

652
790

866

797
830
65

1175
1052
1192
38
300 300

=
704 13 18 664 = =
812
740 704 58
952
740

83
Belt Driven Centrifugal Fans / AT / Technical Data

AT25/25 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 636 mm Impeller weight m 33 kg
Number of blades z 56 Density of media r1 1.2 kg/m
Moment of Inertia J 2.753 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N do not use in this area Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to air performance ratings only.

2500 r

65

54
Pa

69
65
2000 30

57

39
47
kW 22
15 1/min W
1500 11 1000 21

900 19
7.5

1000 800 17
5.5
105 dB 750 16
800 4.0 700 15

3.0 650 14
600
100 600 13
500 2.2
550 12
400 1.5
500 11
95
1.1
300 450 9

0.75 400 8
90
200 0.55
350 7
r
P

150 85
300 6
0.25

100 80
250 5

80 0.12
A7

65
LW

70 75
60 200 4
Normal operation area
SX

50
DX

AT TIC

Pb
pF

40
3000 4000 5000 6000 8000 10000 15000 20000 30000 40000 60000 m/h

0.8 1 2 3 4 5 6 7 8 9 10 20 m/s Measured in


qV
installation B
1.4 2 3 4 5 6 7 8 9 10 14 20 30 m/s according to ISO5801:
v2

0.8 1 2 4 6 8 10 20 40 60 80 100 200 400 600 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point 1/min dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
SX 800 3 5 7 3 -5 -7 -10 -11 -17 dB 9 12 6 -3 -7 -8 -10 -16 dB
SX 500 2 8 8 -2 -3 -7 -7 -13 -19 dB 14 12 1 -3 -6 -6 -11 -19 dB
SX 300 2 12 3 0 -4 -5 -9 -15 -21 dB 17 6 1 -3 -3 -7 -14 -23 dB
qV opt 800 3 4 6 2 -5 -7 -10 -11 -17 dB 8 11 6 -2 -5 -8 -10 -16 dB
qV opt 500 2 7 7 -2 -3 -7 -7 -13 -19 dB 12 11 2 -2 -6 -6 -11 -19 dB
qV opt 300 2 12 3 0 -4 -5 -8 -15 -21 dB 16 7 2 -2 -3 -7 -14 -23 dB
DX 800 2 3 3 -1 -5 -6 -7 -9 -13 dB 6 8 3 -2 -4 -6 -8 -13 dB
DX 500 2 4 2 -5 -4 -6 -7 -10 -15 dB 9 6 -1 -1 -4 -5 -10 -15 dB
DX 300 2 5 1 -2 -4 -5 -8 -11 -18 dB 10 4 1 -2 -3 -7 -12 -21 dB

84
Belt Driven Centrifugal Fans / AT / Technical Data

AT25/25

Dimensions in mm, subject to change.


AT TIC-25/25 105 kg

1060 1010 1013


794 95 438 441
12

52
43
8

=
11

350 350
40

652
790

866

797
830
65

1175
1052
1192
38
350 350

=
834 13 18 794 = =
812
870 834 58
952
870

85
Belt Driven Centrifugal Fans / AT / Technical Data

AT28/20 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 710 mm Impeller weight m 31 kg
Number of blades z 56 Density of media r1 1.2 kg/m
Moment of Inertia J 3.204 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N do not use in this area Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to air performance ratings only.

2500
r
Pa
30

68
2000

58
72
68

46
18.5 1/min W
%

60 900 19
50

1500 kW
11
800 17

7.5
1000 105 dB 700 15
5.5
800
4.0 600 13
100
600 3.0 550 12

500 500 10
2.2

400 95 450 9
1.5
400 8
300 1.1

90 350 7
0.75
200
0.55
300 6
85
150 0.37
250 5
r
P

100 80
0.18
80 65 70 200 4
A7

75
LW

Normal operation area


AT TIC
DX

60
SX

Pb
pF

50
3000 4000 5000 6000 8000 10000 15000 20000 30000 40000 60000 m/h

0.9 1 2 3 4 5 6 7 8 9 10 14 20 m/s Measured in installation B


qV
according to ISO5801:
2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 3 4 6 8 10 20 40 60 80 100 200 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point 1/min dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
SX 700 3 5 7 0 -1 -8 -11 -12 -17 dB 11 12 4 1 -6 -8 -10 -15 dB
SX 450 3 8 4 2 -2 -8 -9 -12 -19 dB 15 8 5 0 -6 -7 -10 -18 dB
SX 250 2 8 5 2 -5 -5 -9 -15 -22 dB 13 8 4 -3 -3 -6 -14 -24 dB
qV opt 700 2 1 5 -1 -2 -7 -10 -11 -15 dB 6 10 2 0 -6 -8 -9 -14 dB
qV opt 450 2 5 3 1 -2 -8 -8 -12 -18 dB 10 7 3 -1 -6 -7 -10 -18 dB
qV opt 250 2 8 3 2 -5 -5 -8 -14 -21 dB 12 7 3 -3 -4 -6 -14 -24 dB
DX 700 2 3 1 -5 -4 -7 -6 -9 -12 dB 6 6 -1 -1 -5 -5 -8 -12 dB
DX 450 1 3 -3 -4 -4 -6 -7 -11 -13 dB 8 1 -1 -2 -4 -6 -10 -14 dB
DX 250 1 0 -2 -2 -4 -4 -8 -11 -16 dB 4 1 0 -3 -3 -8 -12 -19 dB

86
Belt Driven Centrifugal Fans / AT / Technical Data

AT28/20

Dimensions in mm, subject to change.


AT TIC-28/20 120 kg

1040 1118 1121


676 134 485 488
12

52
43
8

=
11

400 400
40

718
863

939

870
90

903

1294
1171
1311
38
300 300

=
726 17 22 676 = =
920
772 716 58
1060
752

87
Belt Driven Centrifugal Fans / AT / Technical Data

AT28/28 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 710 mm Impeller weight m 35 kg
Number of blades z 56 Density of media r1 1.2 kg/m
Moment of Inertia J 3.867 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N do not use in this area Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to air performance ratings only.

r
2500
Pa

65

54
69
2000

66

42
1/min W
57 30
900 19
%

kW
48

1500
18.5
800 17
15

1000 11 700 15

105 dB
800 7.5
600 13

5.5 550 12
600
100
4.0 500 11
500
3.0 450 10
400
2.2 95
400 8
300
1.5
350 7
90
1.1
200
300 6
0.75
150 85
0.55
r
P

250 5

0.37
100
7

80
WA
L

65 70 200 4
80 75

Normal operation area


DX

AT TIC

60
SX

Pb
pF

50
5000 6000 8000 10000 15000 20000 30000 40000 60000 80000 100000 m/h

1.4 2 3 4 5 6 7 8 9 10 14 20 30 m/s Measured in installation B


qV
according to ISO5801:
2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

3 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point 1/min dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
SX 600 3 9 10 -1 -3 -9 -11 -13 -19 dB 13 14 2 -1 -7 -9 -12 -18 dB
SX 400 2 14 2 1 -3 -7 -9 -14 -18 dB 18 5 3 -1 -5 -8 -13 -19 dB
SX 250 2 12 3 2 -4 -6 -9 -15 -19 dB 16 6 3 -2 -4 -8 -15 -22 dB
qV opt 600 2 7 8 -1 -2 -8 -9 -12 -16 dB 11 11 2 -1 -6 -8 -11 -16 dB
qV opt 400 2 11 0 1 -3 -6 -8 -12 -18 dB 15 3 3 -1 -5 -7 -12 -19 dB
qV opt 250 1 8 3 1 -4 -5 -9 -14 -19 dB 12 6 3 -2 -4 -8 -14 -22 dB
DX 600 2 7 5 -2 -5 -7 -7 -10 -13 dB 11 9 2 -2 -5 -6 -9 -13 dB
DX 400 2 8 -1 -1 -5 -5 -7 -10 -14 dB 12 2 2 -3 -4 -6 -10 -16 dB
DX 250 1 4 1 -3 -4 -5 -8 -11 -17 dB 7 4 0 -2 -3 -7 -12 -20 dB

88
Belt Driven Centrifugal Fans / AT / Technical Data

AT28/28

Dimensions in mm, subject to change.


AT TIC-28/28 127 kg

1238 1118 1121


870 136 485 488
12

52
43
8

=
11

400 400
40

718
863

939

870
90

903

1294
1171
1311
38
400 400

=
920 17 22 870 = =
920
966 910 58
1060
946

89
Belt Driven Centrifugal Fans / AT / Technical Data

AT30/20 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 762 mm Impeller weight m 34 kg
Number of blades z 64 Density of media r1 1.2 kg/m
Moment of Inertia J 4.378 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N do not use in this area Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to air performance ratings only.

r
2500

69

59
1/min W

73
Pa 30

47
69
2000 kW

62
900 19

52
18.5
15 800 17
1500
11
700 15

1000 7.5
105 dB
600 13
800 5.5
550 12
4.0
600 100 500 11
3.0
500 450 10
2.2
400
95 400 8
1.5
300 350 7
1.1
90

0.75 300 6
200
0.55
85
r
P

150 250 5

80
100 0.25
200 4

80
75
A7
LW

0.12
60
60 65 150 3
50 70
AT TIC

Normal operation area


DX

Pb
SX
pF

40
3000 4000 5000 6000 8000 10000 15000 20000 30000 40000 60000 80000 100000 m/h
Measured in
1 2 3 4 5 6 7 8 9 10 20 30 m/s installation B
qV
according to
1.4 2 3 4 5 6 7 8 9 10 14 20 30 40 50 m/s ISO5801:
v2

1 2 4 6 8 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point 1/min dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
SX 600 3 6 7 2 -2 -10 -11 -12 -18 dB 12 13 6 0 -8 -9 -10 -16 dB
SX 400 3 9 6 3 -3 -9 -9 -13 -20 dB 15 10 5 -1 -6 -7 -11 -20 dB
SX 250 2 11 7 2 -6 -6 -8 -15 -21 dB 16 10 4 -4 -4 -6 -14 -23 dB
qV opt 600 2 7 6 1 -2 -8 -10 -12 -16 dB 12 11 5 -1 -7 -9 -10 -16 dB
qV opt 400 2 8 4 2 -3 -8 -9 -12 -18 dB 14 9 4 -2 -7 -7 -11 -19 dB
qV opt 250 2 9 5 2 -5 -6 -8 -13 -20 dB 13 8 3 -4 -4 -6 -13 -23 dB
DX 600 2 8 3 -3 -4 -7 -7 -10 -12 dB 13 8 2 -2 -5 -5 -9 -12 dB
DX 400 2 8 -2 -3 -4 -6 -7 -10 -13 dB 13 3 0 -2 -4 -6 -10 -14 dB
DX 250 1 2 -1 -2 -5 -5 -8 -10 -15 dB 7 3 1 -3 -3 -7 -11 -18 dB

90
Belt Driven Centrifugal Fans / AT / Technical Data

AT30/20

Dimensions in mm, subject to change.


AT TIC-30/20 131 kg

1040 1196 1200


676 134 516 520
12

52
43
8

=
11

425 425
40

776
1005
929

936
90

969

1393
1270
1410
38
300 300

=
726 17 22 676 = =
998
772 716 58
1138
752

91
Belt Driven Centrifugal Fans / AT / Technical Data

AT30/28 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 762 mm Impeller weight m 40 kg
Number of blades z 64 Density of media r1 1.2 kg/m
Moment of Inertia J 5.07 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal.
N all types suitable The ratings shown are based on tests and procedures performed in accordance with AMCA
N do not use in this area Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to air performance ratings only.

r
2500 1/min W

58
68
71
Pa

45
68
30

%
2000 900 19

61
kW

51
18.5
15 800 17
1500
11 110 dB 700 15

1000 7.5
600 13
800 5.5 105
550 12
4.0
600 500 11
3.0
500 100 450 9
2.2
400 400 8
1.5 95
300 350 7
1.1

90 300 6
0.75
200
0.55

150 250 5
85
0.37
r
P

80
100 200 4

80 0.18
A7
LW

75
60 65
60 150 3
70
50
AT TIC
DX

Normal operation area


Pb
SX
pF

40
3000 4000 5000 6000 8000 10000 15000 20000 30000 40000 60000 80000 100000 m/h
Measured in
1 2 3 4 5 6 7 8 9 10 20 30 m/s installation B
qV
according to
1.4 2 3 4 5 6 7 8 9 10 14 20 30 m/s ISO5801:
v2

0.8 1 2 4 6 8 10 20 40 60 80 100 200 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point 1/min dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
SX 600 3 9 11 -2 -5 -7 -11 -13 -19 dB 14 15 1 -4 -5 -9 -12 -18 dB
SX 400 2 14 5 -2 -3 -6 -9 -13 -19 dB 18 9 0 -1 -5 -8 -12 -20 dB
SX 250 2 14 2 0 -2 -6 -9 -15 -21 dB 18 5 1 0 -5 -8 -15 -24 dB
qV opt 600 3 8 10 -2 -4 -7 -10 -12 -17 dB 12 14 1 -2 -5 -9 -11 -16 dB
qV opt 400 2 12 4 -1 -3 -6 -9 -12 -18 dB 16 8 1 -1 -5 -7 -11 -19 dB
qV opt 250 2 13 2 0 -3 -6 -9 -14 -20 dB 17 5 2 -1 -5 -7 -14 -23 dB
DX 600 3 9 8 -2 -5 -7 -8 -11 -13 dB 13 12 2 -2 -5 -7 -9 -13 dB
DX 400 2 11 2 -2 -4 -6 -8 -10 -14 dB 15 5 2 -2 -4 -6 -10 -15 dB
DX 250 2 8 1 -2 -3 -5 -8 -10 -17 dB 12 4 1 -1 -4 -7 -11 -20 dB

92
Belt Driven Centrifugal Fans / AT / Technical Data

AT30/28

Dimensions in mm, subject to change.


AT TIC-30/28 138 kg

1238 1196 1200


870 136 516 520
12

52
43
8

=
11

425 425
40

776
929

1005

936
90

969

1393
1270
1410
38
400 400

=
920 17 22 870 = =
998
966 910 58
1138
946

93
Belt Driven Centrifugal Fans / AT / Twin fan arrangement

AT G2L

Dimensions in mm, subject to change.


AT G2L 07/07-18/18
A A1
G G1
M
E X1
H E

17
Q

F
C

B1
B
X4
X2
172 224 28

S
P P US
X3 6
L K
R V
AT G2L 07/07-10/10 AT G2L 12/09-18/18 AT G2L 07/07-18/18
t

t1
t1

F2
D2
B2
d d

F2
w w

A2
E2 E2
z z C2

AT G2L 07/07-18/18
A B C E F G H L M P Q R
7/7 316 325 208 232 186 153 184 698 808 258 203 169
9/7 380 387 262 232 215 185 184 698 808 258 253 199
9/9 380 387 262 298 215 185 244 890 1000 324 253 199
10/8 425 443 289 265 249 203 214 794 904 291 287 227
10/10 425 443 289 331 249 203 264 976 1086 357 287 227
12/09 491 521 341 309 294 230 244 912 1082 335 332 266
12/12 491 521 341 395 294 230 324 1164 1334 425 332 266
15/11 569 609 404 373 342 264 294 1190 1260 399 380 309
15/15 569 609 404 471 342 264 384 1376 1546 497 380 309
18/13 684 739 478 430 415 314 343 1253 1423 456 457 376
18/18 684 739 478 557 415 314 458 1622 1792 583 457 376

S V K X1 X2 X3 X4 US t t1 w z d
7/7 145 147 225 117 86 88 47 1116 19 60 65 20
9/7 177 179 300 119 124 123 120 1116 19 60 65 20
9/9 177 179 300 119 124 123 120 1116 19 60 65 20
10/8 198 197 340 136 132 135 132 1116 19 60 73 20
10/10 198 197 340 136 132 135 132 1116 19 60 73 20
12/09 232 224 408 161 153 161 153 1116 8 28 90 105 25
12/12 232 224 408 161 153 161 153 1116 8 28 90 105 25
15/11 272 258 495 197 211 201 200 1116 8 28 90 105 25
15/15 272 258 495 197 211 201 200 1116 8 28 90 105 25
18/13 340 307 608 262 283 278 288 1116 8 28 90 110 25
18/18 340 307 608 262 283 278 288 1116 8 28 90 110 25

A1 B1 G1 A2 B2 C2 D2 E2 F2
7/7 319 350 156 232 201 288 257 131.0 115.5
9/7 383 412 188 232 255 288 311 131.0 142.5
9/9 383 412 188 298 255 354 311 164.0 142.5
10/8 428 469 206 265 284 321 340 147.5 157.0
10/10 428 469 206 331 284 387 340 180.5 157.0
12/09 494 546 233 309 334 365 390 169.5 182.0
12/12 494 546 233 395 334 451 390 212.5 182.0
15/11 572 634 267 373 397 429 453 201.5 213.5
15/15 572 634 267 471 397 527 453 250.5 213.5
18/13 687 764 317 430 471 486 527 230.0 250.5
18/18 687 764 317 557 471 316 527 293.5 250.5

94
Belt Driven Centrifugal Fans / AT / Twin fan arrangement

AT SC2

Dimensions in mm, subject to change.


AT SC2 7/7-18/18
M H H1
R E Q E K G G1

S
=

F
C

B1
X2
B
172 224 28
US

=
P V P = X1 =
L A

AT SC2 7/7-18/18 AT SC2 7/7-18/18


t

t1
9

F2
D2
B2
d

F2
w

A2
E2 E2
z C2

AT SC2 7/7-18/18
A B C E F G H L M P Q R
7/7 285 337 208 232 186 153 321 686 843 254 182 20
9/7 349 399 262 232 215 185 385 684 843 254 180 20
9/9 349 399 262 298 215 185 385 872 1033 320 236 20
10/8 395 455 289 265 249 203 431 773 950 287 203 20
10/10 395 455 289 331 249 203 431 957 1134 353 255 20
12/9 461 533 341 309 294 230 497 913 1066 339 239 28
12/12 461 533 341 395 294 230 497 1165 1316 425 319 28
15/11 539 621 404 373 342 264 575 1094 1243 403 292 28
15/15 539 621 404 471 342 264 575 1384 1537 501 386 28
18/13 654 751 477 430 415 314 690 1262 1425 470 326 38
18/18 654 751 477 557 415 314 690 1647 1805 597 457 38

S V K X1 X2 US t t1 w z d
7/7 6 160 78.5 210 262 912 6 23 60 75.5 20
9/7 6 158 79.5 274 324 912 6 23 60 76.5 20
9/9 6 214 80.5 274 324 912 6 23 60 77.5 20
10/8 6 181 88.5 330 390 912 6 23 60 85.5 20
10/10 6 233 88.5 330 390 912 6 23 60 85.5 20
12/9 6 209 76.5 371 443 1116 8 28 65 79.5 25
12/12 6 289 75.5 371 443 1116 8 28 65 78.5 25
15/11 6 262 74.5 449 531 1116 8 28 65 77.5 25
15/15 6 356 76.5 449 531 1116 8 28 65 79.5 25
18/13 6 286 81.5 544 641 1116 8 28 65 84.5 25
18/18 6 417 79.0 544 641 1116 8 28 65 82.0 25

B1 G1 H1 A2 B2 C2 D2 E2 F2
7/7 350 156 324 232 201 288 257 131.0 115.5
9/7 418 188 388 232 255 288 311 131.0 142.5
9/9 418 188 388 298 255 354 311 164.0 142.5
10/8 475 206 434 265 284 321 340 147.5 157.0
10/10 475 206 434 331 284 387 340 180.5 157.0
12/9 552 233 500 309 334 365 390 169.5 182.0
12/12 552 233 500 395 334 451 390 212.5 182.0
15/11 640 267 578 373 397 429 453 201.5 213.5
15/15 640 267 578 471 397 527 453 250.5 213.5
18/13 770 317 693 430 471 486 527 230.0 250.5
18/18 770 317 693 557 471 613 527 293.5 250.5

95
Belt Driven Centrifugal Fans / AT / Twin fan arrangement

AT G2C

Dimensions in mm, subject to change.


AT G2C 09/07-18/18
M H H1
R E Q E K G G1

S
=

F
C

B1
X2
B
172 224 28

=
P US = X1 =
L A V

AT G2C 09/07-18/18 AT G2C 09/07-18/18


t

t1
9

F2
D2
B2
d

F2
w
A2
E2 E2
z C2

AT G2C 09/07-18/18
A B C E F G H L M P Q R
9/7 347 423 262 232 215 185 385 704 864 678 184 28
9/9 347 423 262 298 215 185 385 896 1056 870 244 28
10/8 393 479 289 265 249 203 431 800 960 774 214 28
10/10 393 479 289 331 249 203 431 982 1142 956 264 28
12/09 457 580 341 309 294 230 497 938 1158 902 244 38
12/12 457 580 341 395 294 230 497 1190 1410 1154 324 38
15/11 533 667 404 373 342 264 575 1116 1336 1080 294 38
15/15 533 667 404 471 342 264 575 1402 1622 1366 384 38
18/13 646 797 478 430 415 314 690 1299 1519 1253 343 48
18/18 646 797 478 557 415 314 690 1668 1888 1622 458 48

S V K X1 X2 t t1 w z d us
9/7 31 38 80 257 333 8 33 55 60 30 13x18
9/9 31 38 80 257 333 8 33 55 60 30 13x18
10/8 31 38 80 289 375 8 33 55 60 30 13x18
10/10 31 38 80 289 375 8 33 55 60 30 13x18
12/09 52 40 110 327 450 10 38 90 91 35 13x18
12/12 52 40 110 327 450 10 38 90 91 35 13x18
15/11 52 42 110 403 537 10 38 90 91 35 13x18
15/15 52 42 110 403 537 10 38 90 91 35 13x18
18/13 52 44 110 506 657 12 43 90 97 40 17x22
18/18 52 44 110 506 657 12 43 90 97 40 17x22

B1 G1 H1 A2 B2 C2 D2 E2 F2
9/7 418 188 388 232 255 288 311 131.0 142.5
9/9 418 188 388 298 255 354 311 164.0 142.5
10/8 475 206 434 265 284 321 340 147.5 157.0
10/10 475 206 434 331 284 387 340 180.5 157.0
12/09 553 233 500 309 334 365 390 169.5 182.0
12/12 553 233 500 395 334 451 390 212.5 182.0
15/11 640 267 578 373 397 429 453 201.5 213.5
15/15 640 267 578 471 397 527 453 250.5 213.5
18/13 770 317 693 430 471 486 527 230.0 250.5
18/18 770 317 693 557 471 613 527 293.5 250.5

96
Belt Driven Centrifugal Fans / AT / Twin fan arrangement

AT G2C

Dimensions in mm, subject to change.


AT G2C 20/15-30/28
M H H1
R E Q E K G G1

S
=

F
C

B1
X2
B
38

=
P US = X1 =
L A V

AT G2C 20/15-30/28 AT G2C 20/15-30/28


t

t1
11

H2

D2
B2
F2
d

H2
w

G2 G2
A2
z E2
C2
AT G2C 20/15-30/28
A B C E F G H L M P Q R
20/15 772 967 629 502 520 369 830 1470 1730 1424 370 48
20/20 772 967 629 630 520 369 830 1866 2126 1820 510 48
22/15 847 1058 695 514 573 398 905 1470 1730 1424 346 48
22/22 847 1058 695 692 573 398 905 2050 2310 2004 570 48
25/20 952 1192 797 664 652 438 1010 1934 2194 1888 510 48
25/25 952 1192 797 794 652 438 1010 2240 2500 2194 556 48
28/20 1060 1311 870 676 718 485 1118 1958 2220 1912 510 48
28/28 1060 1311 870 870 718 485 1118 2550 2810 2504 714 48
30/20 1138 1410 936 676 776 516 1196 1958 2220 1912 510 48
30/28 1138 1410 936 870 776 516 1196 2550 2810 2504 714 48

S V K X1 X2 US t t1 w z d
20/15 52 58 130 632 827 1722 12 43 90 117 40
20/20 52 58 130 632 827 1722 12 43 90 117 40
22/15 52 58 130 707 918 1722 12 43 90 117 40
22/22 52 58 130 707 918 1722 12 43 90 117 40
25/20 52 58 130 812 1052 1722 12 43 90 117 40
25/25 52 58 130 812 1052 1722 12 43 90 117 40
28/20 52 58 131 920 1171 1722 12 43 90 118 40
28/28 52 58 130 920 1171 1722 12 43 90 117 40
30/20 52 58 131 998 1270 1722 12 43 90 118 40
30/28 52 58 130 998 1270 1722 12 43 90 117 40

B1 G1 H1 A2 B2 C2 D2 E2 F2 G2 H2
20/15 950 372 833 502 622 578 698 542 662 200 275
20/20 950 372 833 630 622 706 698 670 662 275 275
22/15 1041 401 908 514 688 590 764 554 728 225 300
22/22 1041 401 908 692 688 768 764 732 728 300 300
25/20 1175 441 1013 664 790 740 866 704 830 300 350
25/25 1175 441 1013 794 790 870 866 834 830 350 350
28/20 1293 488 1121 676 863 752 939 716 903 300 400
28/28 1293 488 1121 870 863 946 939 910 903 400 400
30/20 1393 520 1200 676 929 752 1005 716 969 300 425
30/28 1393 520 1200 870 929 946 1005 910 969 400 425

97
Belt Driven Centrifugal Fans / AT / Twin fan arrangement

AT G2C-C2

Dimensions in mm, subject to change.


AT G2C-C2 20/15-30/28
M H H1
R E Q E K G G1

S
=

B1
C
X2
B
38

=
P US = X1 =
L A V

AT G2C-C2 20/15-30/28 AT G2C-C2 20/15-30/28


t
11

t1

H2

D2
B2
F2
d

H2
w
G2 G2
A2
z E2
C2
AT G2C-C2 20/15-30/28
A B C E F G H L M P Q R
20/15 772 967 629 502 520 369 830 1470 1816 1424 370 48
20/20 772 967 629 630 520 369 830 1866 2212 1820 510 48
22/15 847 1058 695 514 573 398 905 1470 1816 1424 346 48
22/22 847 1058 695 692 573 398 905 2050 2396 2004 570 48
25/20 952 1192 797 664 652 438 1010 1934 2280 1888 510 48
25/25 952 1192 797 794 652 438 1010 2240 2586 2194 556 48
28/20 1060 1311 870 676 718 485 1118 1958 2304 1912 510 48
28/28 1060 1311 870 870 718 485 1118 2550 2896 2504 714 48
30/20 1138 1410 936 676 776 516 1196 1958 2304 1912 510 48
30/28 1138 1410 936 870 776 516 1196 2550 2896 2504 714 48

S V K X1 X2 US t t1 w z d
20/15 52 58 173 632 827 1722 14 48 90 130 45
20/20 52 58 173 632 827 1722 14 48 90 130 45
22/15 52 58 173 707 918 1722 14 48 90 130 45
22/22 52 58 173 707 918 1722 14 48 90 130 45
25/20 52 58 173 812 1052 1722 14 48 90 130 45
25/25 52 58 173 812 1052 1722 14 48 90 130 45
28/20 52 58 173 920 1171 1722 14 48 90 130 45
28/28 52 58 173 920 1171 1722 14 48 90 130 45
30/20 52 58 173 998 1270 1722 14 48 90 130 45
30/28 52 58 173 998 1270 1722 14 48 90 130 45

B1 G1 H1 A2 B2 C2 D2 E2 F2 G2 H2
20/15 950 372 833 502 622 578 698 542 662 200 275
20/20 950 372 833 630 622 706 698 670 662 275 275
22/15 1041 401 908 514 688 590 764 554 728 225 300
22/22 1041 401 908 692 688 768 764 732 728 300 300
25/20 1175 441 1013 664 790 740 866 704 830 300 350
25/25 1175 441 1013 794 790 870 866 834 830 350 350
28/20 1293 488 1121 676 863 752 939 716 903 300 400
28/28 1293 488 1121 870 863 946 939 910 903 400 400
30/20 1393 520 1200 676 929 752 1005 716 969 300 425
30/28 1393 520 1200 870 929 946 1005 910 969 400 425

98
Belt Driven Centrifugal Fans / Notes

Notes

Notes

99
Belt Driven Centrifugal Fans / AT / Specifications

ATS 7/7-18/18

Specifications
High performance centrifugal fan AT S
Double width double inlet (DWDI) belt driven fan, with forward curved blades.
Lap-jointed scroll of galvanized steel EN10142 assembled with roller-lock seaming.
Straight cut off plate at fan outlet.
Impeller with forward curved blades of galvanized steel EN10142, statically and
dynamically balanced to grade G4, according to UNI ISO1940.
Light construction, without side frames.
Single row, deep groove, self-aligning ball bearings, lubricated and sealed for life, with
eccentric collar locking. Bearings are mounted inside conductive rubber vibration
absorbers on bearing supporting spiders.
The mounting feet, which allow the fan to be installed in the 4 positions 0, 90, 180
and 270, as well as the outlet flange, are available on request.
For sizes from 7/7 to 10/10, in addition to the standard construction version with flats
on shaft ends (type 1), it is also available a version with keyways (type 2).
Shaft ends of larger sizes are only of Type 2.

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Mounting feet
Motor brackets (Pick-A-Back)
Discharge flange
Discharge flex with flexible sleeve
Inlet guards
Discharge guard
Shaft guard for free shaft end
Matching flange

Options may be available only for orders of a minimum quantity, to be previously


agreed
Inspection door
Drain plug
Single or double thickness powder coating
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone

100
Belt Driven Centrifugal Fans / AT / Specifications

ATSC7/7-18/18
ATC7/7-18/18
Specifications
High performance centrifugal fan AT SC and AT C
Double width double inlet (DWDI) belt driven fan, with forward curved blades.
Lap-jointed scroll of galvanized steel EN10142 assembled through roller-lock
seaming.
Straight cut off plate at fan outlet.
Impeller with forward curved blades of galvanized steel EN10142, statically and
dynamically balanced to grade G4, according to UNI ISO1940.
Construction with two side frames, made of cold-formed galvanized steel angular
sections welded to the side plates, for a better strength and stiffness of the fan
structure.
Single row, deep groove, self-aligning ball bearings, lubricated and sealed for life, with
eccentric collar locking. Bearings are mounted inside conductive rubber vibration
absorbers on bearing supporting spiders.
It can be easily installed in four different positions.
Discharge flange on request.
Where an even better mechanical strength is required, e.g. when the fan itself is used
as a stiffening element of the base frame, a further reinforced version is available. It is
identified by the letter C.
This version is available in the same sizes as the SC version, with the same dimensi-
ons and the same performance limits. With the addition of three steel bars, welded
between three corners of the side frames, the frames of these fans are joined to form
a closed, box-like supporting structure.
For sizes from 7/7 to 10/10, in addition to the standard construction version with flats
on shaft ends (type 1), it is also available a version with keyways (type 2).
Shaft ends of larger sizes are only of Type 2.

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Mounting feet
Motor brackets (Pick-A-Back)
Discharge flange
Discharge flex with flexible sleeve
Inlet guards
Discharge guard
Shaft guard for free shaft end
Matching flange

Options may be available only for orders of a minimum quantity, to be previously


agreed
Inspection door
Drain plug
Single or double thickness powder coating
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone

101
Belt Driven Centrifugal Fans / AT / Specifications

ATAR 9/7-18/18

Specifications
High performance centrifugal fan ATAR
Double width double inlet (DWDI) belt driven fan, with forward curved blades.
Lap-jointed scroll of galvanized steel EN10142 assembled with roller-lock seaming.
Straight cut off plate at fan outlet.
Impeller with forward curved blades of galvanized steel EN10142, statically and
dynamically balanced to grade G4, according to UNI ISO1940.
For applications requiring even higher installed power, or where there is a requirement
for re-lubricatable bearings, the AR version is the correct solution.
The reinforced side-frames are made of galvanized steel sections, welded to the sides
of the scroll and joined together in three corners.
Single row, deep groove, self-aligning ball bearings, re-lubricatable and reinforced,
with eccentric collar locking. Bearings are mounted inside a single-piece cast iron
pillow block.
It can be easily installed in four different positions.
Discharge flange on request.

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Mounting feet
Motor brackets (Pick-A-Back)
Discharge flange
Discharge flex with flexible sleeve
Inlet guards
Discharge guard
Shaft guard for free shaft end
Matching flange

Options may be available only for orders of a minimum quantity, to be previously


agreed
Inspection door
Drain plug
Single or double thickness powder coating
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone

102
Belt Driven Centrifugal Fans / AT / Specifications

ATTIC 20/15-30/28

Specifications
High performance centrifugal fan ATTIC
Double width double inlet (DWDI) belt driven fan, with forward curved blades.
Lap-jointed scroll of galvanized steel EN10142 assembled with Pittsburgh lock seam.
Straight cut off plate at fan outlet.
Impeller with forward curved blades of galvanized steel EN10142, statically and
dynamically balanced with grade G4, according to UNI ISO1940.
Mechanically designed in a way very similar to the previous version, apart for the
larger sized impeller and a fourth traverse, so the frames on the sides are joined
together in all the four corners.
Single row, deep groove, self-aligning ball bearings, re-lubricatable and reinforced,
with eccentric collar locking. Bearings are mounted inside a single-piece cast iron
pillow block.
It can be easily installed in four different positions.
Discharge flange on request.

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Mounting feet
Motor brackets (Pick-A-Back)
Discharge flange
Discharge flex with flexible sleeve
Inlet guards
Discharge guard
Shaft guard for free shaft end

Options may be available only for orders of a minimum quantity, to be previously


agreed
Matching flange
Inspection door
Drain plug
Single or double thickness powder coating
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone

103
Belt Driven Centrifugal Fans / AT / Specifications

ATG2L 7/7-18/18

Specifications
High performance centrifugal twin fan AT G2L
(size from 7/7 to 18/18)
Lap-jointed scroll of galvanized steel EN10142 assembled with roller-lock seaming.
This twin version is made with two S version single fans, connected through three
U-section spars and is fitted with two double-inlet impellers mounted on a common
shaft, supported by three bearings.

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Mounting feet
Motor brackets (Pick-A-Back)
Discharge flange
Discharge flex with flexible sleeve
Inlet guards
Discharge guard
Shaft guard for free shaft end
Matching flange

Options may be available only for orders of a minimum quantity, to be previously


agreed
Inspection door
Drain plug
Single or double thickness powder coating
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone

104
Belt Driven Centrifugal Fans / AT / Specifications

ATSC27/7-18/18

Specifications
High performance centrifugal twin fan AT-SC2
(size from 7/7 to 18/18)
Lap-jointed scroll of galvanized steel EN10142 assembled with roller-lock seaming.
Twin version, made of two SC version fans, joined by three L-section spars, welded in
the corners of the side frames.
Two double-inlet impellers are mounted on a single shaft, supported by three bearings
on rubber shock absorbers and inlet-mounted supporting spiders.
The SC2 fans have the same characteristics of the G2L versions but with the additio-
nal stiffness provided by the welded frame.

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Mounting feet
Motor brackets (Pick-A-Back)
Discharge flange
Discharge flex with flexible sleeve
Inlet guards
Discharge guard
Shaft guard for free shaft end
Matching flange

Options may be available only for orders of a minimum quantity, to be previously


agreed
Inspection door
Drain plug
Single or double thickness powder coating
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone

105
Belt Driven Centrifugal Fans / AT / Specifications

ATG2C9/7-30/28
ATG2C-C220/15-30/28
Specifications
High performance centrifugal twin fan AT-G2C
(size from 9/7 to 30/28)
Lap-jointed scroll of galvanized steel EN10142 assembled with roller-lock seaming
(size up to 18/18) or with Pittsburgh lock seam (for sizes larger than 18/18).
Inside a common supporting frame, made of galvanized steel sections, two double-
inlet fans are mounted side-by-side.
They are joined by a single shaft, supported at the ends by two pillow-block bearings,
bolted on the side frames.
This particular design doesnt need a third bearing between the impellers, and weight
is kept low thanks to the use of large section, hollow shafts on the larger sizes.

High performance centrifugal twin fan AT-G2C-C2


(size from 20/15 to 30/28)
Lap-jointed scroll of galvanized steel EN10142 assembled with Pittsburgh lock seam.
The G2C-C2 fan is a reinforced twin unit, suitable to achieve higher speed and power
levels than the G2C.
Mechanical design is similar to that of the G2C fans, but hollow shafts with larger
diameter (45 mm) journals and heavy duty split-block bearings make them stronger.
The G2C-C2 fans retain the other characteristics of the G2C fans.

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Mounting feet
Motor brackets (Pick-A-Back)
Discharge flange
Discharge flex with flexible sleeve
Inlet guards
Discharge guard
Shaft guard for free shaft end
Matching flange

Options may be available only for orders of a minimum quantity, to be previously


agreed
Inspection door
Drain plug
Single or double thickness powder coating
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone

106
Belt Driven Centrifugal Fans / AT / Specifications

ATSC27/7-18/18

Specifications
High performance centrifugal tripple fan ATG3C
(size from 12/9 to 30/28)
Lap-jointed scroll of galvanized steel EN10142 assembled with roller-lock seaming
(size up to 18/18) or with Pittsburgh lock seam (for sizes larger than 18/18)
The G3C is a triple fan: three identical double-inlet units are mounted inside a com-
mon frame of steel sections.
The single, common shaft is supported by just two pillow-block bearings, bolted on
the end frames.
This special version is particularly suited when a large airflow must be distributed on a
wide surface, or when a fan of particularly limited height can be useful.
Other advantages of this design are the use of a single motor, operation without
bearings installed between the impellers, and low weight thanks to the use of hollow
shafts.
Using a common shaft, without intermediate bearings and couplings, provides also a
reliable and smooth operation, with limited operating noise.

High performance centrifugal tripple fan ATG3C-C2


(size from 20/15 to 30/28)
Lap-jointed scroll of galvanized steel EN10142 assembled with Pittsburgh lock seam.
Of similar construction to the G3C version, but employs larger diameter hollow shafts,
with larger diameter journals and heavy-duty bearings on split-type pillow blocks.
These improvements allow operation at higher speed and power levels.
The G3C-C2 fans keep unchanged all the other characteristics of the G3C fans.

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Mounting feet
Motor brackets (Pick-A-Back)
Discharge flange
Discharge flex with flexible sleeve
Inlet guards
Discharge guard
Shaft guard for free shaft end
Matching flange

Options may be available only for orders of a minimum quantity, to be previously


agreed
Inspection door
Drain plug
Single or double thickness powder coating
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone

107
Working towards perfection

The RDHE and RDH series


Like the ADHE range, with the serie RDHE we have taken the next logical step in
further developing our successful RDH range of models.
The aim of our development work is to ensure that the dimensions of all casing for
the RDHE and RDH range are compatible with the relevant sister models from the
forward-curved series (ADHE and ADH). In future, we will also ensure compatibility
with the hollow aerofoil impeller types from the RZR series.
As part of the development work being undertaken across all product ranges, the
quality of the RDHE series has also been improved. For example, it now has standing
seam casing which is manufactured during a fully automatic process, and the impeller
shaft is galvanised.

New choice of models


Whether you are looking for single or twin fans, the new RDHE series offers impres-
sive further improvements in terms of functionality and potential uses, whatever the
application.

The ultimate in compatibility


The RDHE and RDH also entail minimised design effort for you, which means that:

All accessories and equipment are carefully coordinated (and identical with the
ADHE/ADH).
The connection dimensions for RDHE (sizes 0180 to 0560) are identical with the
corresponding models from the old range RDH and the ranges ADH/ADH E.
The models for sizes RDH 0630 to 1000 remain unchanged.
All RDHE models up to size 0500 are compatible with the new compact base
frame a unique feature which makes completing your system ultra simple and
affordable!

Top quality for performance and a long service life!


Alongside an intelligent construction, aspects such as the quality of materials and
workmanship play a crucial role in ensuring a long life cycle. Thats why like the
ADHE we have made the casing of the new RDHE even sturdier by means of a
standing seam construction. Apart from that, the tried and tested quality of our suc-
cessful, long-standing RDH series remains the same. And that means robust impeller
constructions, non-corrosive impeller shafts and quality bearings for a long life with
minimum noise.

108
The product range at a glance

The technical specifications of the RDHE and RDH series.

The standard series are designed for permanent ventilation at up to +80C resp. +100C. According to DIN24166, the specifications conform
to accuracy class 1 (for all sizes from 0355 to 1000) and accuracy class 2 (for all sizes from 0180 to 315).

RDHE and RDH G2E series RDH and RDH G2-0630/-1000 series

Sizes 0180 to 0560 Sizes 0630 up to 1000


Scroll of galvanesed sheet steel with standing seam and V-cut off Lap jointed scroll of galvanised sheet steel assembled by Pittsburgh
Centrifugal impeller with 11 backward inclined blades made of sheet lockforming, with V-cut off.
steel (0250-0560), welded and coated High performance radial impeller with 11 backward inclined bla-
with galvanised shaft des made of sheet steel, welded and painted, balanced acc. to
Volume up to 90.000 m3/h ISO1940.
Pressure up to 3.500 Pa Volume up to 290.000 m3/h
Pressure up to 3.500 Pa

The RDHE and RDH range of models:


The right fan for every specification!

Depending on the fan size, the RDHE and RDH series have up to 5 mechanical versions of the single fan and up to 2 additional twin fan options.
In this way, we ensure that we have the perfect model for all requirements and any application.

Version Description Figure

Lap jointed scroll without feet and discharge flange.


RDH E0
Light duty bearing execution with pressed steel housing/strut assemblies.

Lap jointed scroll with rectangular side frame, without discharge flange.
RDH E2 / RDH R
Light duty bearing execution with pressed steel housing/strut assemblies.

Lap jointed scroll with heavy duty reinforced side frames, without discharge flange.
RDH E4 / RDH K
Medium duty bearing execution with cast iron pillow block, mounted on a robust pedestal.

Lap jointed scroll with heavy duty reinforced side frames, without discharge flange.
RDH E6 / RDH K1 Medium-heavy duty bearing execution with cast iron pillow block, mounted on a robust pedes-
tal.

Lap jointed scroll with heavy duty reinforced side frames, without discharge flange.
RDH E7 / RDH K2 Heavy duty bearing execution with single-piece resp. split-type plummer block, mounted on a
robust pedestal.

Version Description Figure

The two single fans RDH E4 or RDH K are fitted together to a robust assembly by means of
3 angle bars. Both impellers are fitted on a common shaft supported by 3 bearings (sizes
RDH G2E4 / RDH G2K
0250/-0630) or the fans have separated shafts being connected by a elastic coupling (sizes
0710/-1000).

The two single fans RDH E7 or RDH K2 are fitted together to a robust assembly by means
of 3 angle bars. Both impellers are fitted on a common shaft supported by 3 bearings (sizes
RDH G2E7 / RDH G2K2
0250/-0630) or the fans have separated shafts being connected by a elastic coupling (sizes
0710/-1000).

109
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0180 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 180 mm Impeller weight m 0,62 kg
Number of blades z 8 Density of media r1 1,2 kg/m
Moment of Inertia J 0,003 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt
Pa N all types suitable S.p.A certifies that
4500 N do not use in this area the fan shown
4000 herein is licensed

%
3500 to bear the AMCA

58
Seal.

62
3000
kW r The ratings shown

64
2500 1.5 are based on tests
and procedures performed in ac-

62
2000 cordance with AMCAPublication211
1.0
and comply with the requirements of
0.8
the AMCA Certified Ratings Program.

53
1500
0.6 The AMCA Certified Ratings Seal
applies to air performance ratings only.

0.4

41
1000
0.3
800

29
0.2
600 1/min W W
0.15 7500 49 49
500
r
P

6800 45 45
400 0.10 95 dB

6000 40 40
300
5500 36 36
90
5000 33 33
SX

200
4500 30 30

85
150 4000 26 26
Normal operation area 70
3500 23 23
100 80

3000 20 20
80
DX

75
WA

60
L

2500 16 16
RDH E0

RDH E2

Pb
pF

40
N

200 300 400 500 600 800 1000 1500 2000 3000 4000 m/h
Measured in installation B
0.1 0.2 0.3 0.4 0.5 0.6 0.8 1 m/s according to ISO5801:
qV
2 3 4 5 6 7 8 9 10 14 20 m/s
v2

0.8 1 2 4 6 8 10 20 40 60 80 100 200 400 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 6000 4 -14 -6 -2 -5 -5 -6 -11 -17 dB 15 8 3 3 -5 -6 -10 -17 dB
SX 4500 3 -9 -2 -3 -3 -5 -8 -12 -18 dB 16 5 5 2 -6 -6 -12 -19 dB
SX 3000 2 -3 0 -3 -3 -4 -9 -15 -21 dB 10 6 5 -3 -4 -8 -15 -22 dB
qV opt 6000 3 -17 -8 -3 -5 -6 -5 -12 -17 dB 8 6 5 1 -7 -6 -12 -21 dB
qV opt 4500 2 -11 -4 -3 -4 -4 -8 -13 -18 dB 10 6 5 0 -6 -7 -16 -22 dB
qV opt 3000 1 -5 -0 -3 -4 -3 -10 -15 -22 dB 8 7 3 -5 -4 -10 -19 -25 dB
DX 6000 2 -21 -11 -6 -4 -6 -5 -11 -16 dB 5 3 -2 1 -7 -6 -9 -19 dB
DX 4500 1 -15 -7 -5 -4 -4 -8 -12 -17 dB 7 1 0 -1 -6 -6 -12 -21 dB
DX 3000 1 -9 -4 -2 -4 -3 -9 -14 -21 dB 5 0 3 -5 -4 -7 -17 -26 dB

110
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0180

Dimensions in mm, subject to change.


RDH E0-0180 5.3 kg
370 167 154 157
229 319 322

22.5
6

7
6
9
20h7

227

229
195
227
30

344

365
167
130 28

135
229
11 16 2 129.5
259 285 = =
289 180
RDH E2-0180 7.1 kg
370 320 323
20 229 154 157
22.5

8
6

9
20h7

229
195
227
30

346

366
180
130 28

111
229
9 14 2 129.5
253 285 180
269 290 30

111
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0200 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 200 mm Impeller weight m 0,84 kg
Number of blades z 8 Density of media r1 1,2 kg/m
Moment of Inertia J 0,006 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt
Pa N all types suitable S.p.A certifies that

%
4500

53
N RDH E4 only kW the fan shown

59
4000 N do not use in this area 3.0 herein is licensed

65
r
3500 to bear the AMCA

67
3000 Seal.
2.0
The ratings shown
2500 1.5 are based on tests

62
and procedures performed in ac-
2000 cordance with AMCAPublication211
1.0
and comply with the requirements of
0.8 the AMCA Certified Ratings Program.
1500
The AMCA Certified Ratings Seal

46
0.6
applies to air performance ratings only.

1000 0.4

800 0.3

29
1/min W W W
0.2 7600 50 50 50
600
r
P

0.15
500 6800 45 45 45
100 dB
400 6000 40 40 40

5500 36 36 36
300 95
5000 33 33 33
SX

4500 30 30 30
200 90
Normal operation area 4000 26 26 26
150
3500 23 23 23
85

75
DX

100 3000 20 20 20

80 80
7
WA
L

2500 16 16 16
60
RDH E0

RDH E2

RDH E4

Pb
pF

40
N

300 400 500 600 800 1000 1500 2000 3000 4000 5000 6000 m/h
Measured in installation B
0.1 0.2 0.3 0.4 0.5 0.6 0.8 1 1.4 2 m/s according to ISO5801:
qV
2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

1 2 4 6 8 10 20 40 60 80 100 200 400 600 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 5500 5 -5 -5 -5 -3 -5 -8 -11 -17 dB 25 10 5 4 -6 -7 -11 -17 dB
SX 4500 4 -5 -5 -5 -3 -5 -8 -11 -17 dB 22 7 7 2 -7 -7 -12 -18 dB
SX 3000 3 -5 -5 -5 -3 -5 -8 -11 -17 dB 14 7 7 -2 -5 -8 -14 -18 dB
qV opt 5500 4 -4 -2 -1 -4 -6 -7 -9 -13 dB 19 11 7 1 -8 -7 -11 -17 dB
qV opt 4500 3 -3 -1 -2 -3 -6 -9 -9 -14 dB 16 10 6 -1 -8 -8 -13 -18 dB
qV opt 3000 1 -0 1 -2 -4 -5 -8 -10 -18 dB 14 9 3 -5 -6 -9 -15 -21 dB
DX 5500 2 -7 -4 -3 -5 -6 -6 -10 -13 dB 19 7 0 -1 -8 -5 -8 -17 dB
DX 4500 2 -6 -3 -4 -4 -5 -8 -11 -11 dB 18 3 1 -1 -7 -6 -11 -16 dB
DX 3000 0 -3 -2 -4 -4 -4 -8 -12 -12 dB 10 2 1 -6 -5 -6 -15 -17 dB

112
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0200

Dimensions in mm, subject to change.


RDH E0-0200 6.6 kg
420 189 163 166
256 348 351

22.5
6

6
6
9
20h7

250

256
216
258
30

378

400
186
130 28

144
256
11 16 2 143
286 312 = =
316 224
RDH E2-0200 8.5 kg
420 348 351
25 256 163 166
22.5

8
6

9
20h7

256
216
258
30

379

399
224
130 28

113
256
11 16 2 143
286 312 224
306 312 36
RDH E4-0200 11.8 kg
420 348 351
25 256 163 166
22.5

8
6

9
20h7

256
216
258
30
379

399
224

130 28
113

256
11 16 2 143
286 312 224
306 312 36

113
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0225 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 225 mm Impeller weight m 1,3 kg
Number of blades z 8 Density of media r1 1,2 kg/m
Moment of Inertia J 0,011 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt
Pa N all types suitable S.p.A certifies that
4500

%
N RDH E4 only the fan shown

59
49
4000

66
N do not use in this area kW 4.0 herein is licensed
3500 r to bear the AMCA

69
3.0
3000 Seal.
The ratings shown
2.0

64
2500 are based on tests
1.5 and procedures performed in ac-
2000 cordance with AMCAPublication211
and comply with the requirements of

52
1.0
1500 the AMCA Certified Ratings Program.
0.8 The AMCA Certified Ratings Seal
applies to air performance ratings only.
0.6

35
1000 1/min W W W
0.4
6500 43 43 43
800
0.3 6000 40 40 40
5800 38 38 38
600 95 dB
0.2
r
P

500 5000 33 33 33

400 0.12 4500 30 30 30


90

4000 26 26 26
300

85 3500 23 23 23
SX

200
3000 20 20 20
Normal operation area
80
150
2600 17 17 17
70

2300 15 15 15
7

75
WA

100
L
DX

80 2000 13 13 13

60
RDH E0

RDH E2

RDH E4

Pb
pF

40
N

400 500 600 800 1000 1500 2000 3000 4000 5000 6000 8000 m/h
Measured in installation B
0.2 0.3 0.4 0.5 0.6 0.8 1 1.4 2 m/s
qV according to ISO5801:

2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 3 4 5 7 10 20 40 60 80 100 200 400 600 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 5000 5 -6 -0 0 -2 -6 -8 -13 -17 dB 21 8 7 4 -7 -7 -13 -17 dB
SX 3500 3 -4 3 -1 -2 -5 -10 -13 -19 dB 14 8 7 0 -6 -9 -14 -19 dB
SX 2300 2 4 3 1 -3 -6 -10 -14 -20 dB 11 10 6 -4 -4 -10 -15 -21 dB
qV opt 5000 3 -6 -1 -1 -2 -6 -7 -12 -16 dB 16 11 6 1 -9 -7 -14 -21 dB
qV opt 3500 1 -4 2 -3 -1 -5 -9 -13 -17 dB 12 10 3 -1 -7 -9 -18 -21 dB
qV opt 2300 1 3 1 1 -3 -5 -9 -13 -20 dB 14 8 4 -6 -4 -12 -18 -22 dB
DX 5000 2 -11 -4 -2 -4 -6 -6 -12 -16 dB 14 6 2 0 -8 -5 -11 -20 dB
DX 3500 1 -8 0 -4 -3 -4 -9 -13 -16 dB 10 5 1 -3 -6 -7 -15 -21 dB
DX 2300 1 0 -1 -1 -3 -4 -10 -13 -18 dB 8 4 2 -5 -3 -10 -18 -21 dB

114
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0225

Dimensions in mm, subject to change.


RDH E0-0225 7.8 kg
450 209 182 185
288 388 391

22.5
6

7
6
9
20h7

279

288
241
287
30

422

443
202
130 28

156
288
11 16 2 159
318 344 = =
348 224
RDH E2-0225 9.9 kg
450 390 393
25 288 182 185
22.5

11
6

9
20h7

288
241
287
30

425

442
224
130 28

127
288
11 16 2 159
318 344 224
338 351 39
RDH E4-0225 13.6 kg
450 390 393
25 288 182 185
22.5

11
6
6

9
20h7

288
241
287
30
425

442
224

130 28
127

288
11 16 2 159
318 344 224
338 351 39

115
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0250 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 252 mm Impeller weight m 4,87 kg
Number of blades z 11 Density of media r1 1,2 kg/m
Moment of Inertia J 0,044 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt

%
Pa N all types suitable S.p.A certifies that

53

67
4500 kW 5.5
N RDH E4 only 4.0
the fan shown
4000 7.5

76
N do not use in this area r herein is licensed
3500 3.0 to bear the AMCA

72
3000 Seal.
The ratings shown
2500 2.0
are based on tests

61
1.5 and procedures performed in ac-
2000 cordance with AMCAPublication211
and comply with the requirements of
1.0

46
1500 the AMCA Certified Ratings Program.
0.8 The AMCA Certified Ratings Seal
applies to air performance ratings only.
0.6
1000

31
1/min W W W
0.4 6000 40 40 72
800
0.3
5400 36 36 65
r
P

600
0.2
500 4600 30 30 55
100 dB
400
4000 26 26 48

300 3600 24 24 43
95
SX

3200 21 21 38

200 75
Normal operation area 90 2800 18 18 34

150

2300 15 15 28
DX

85
100

80 1800 12 12 22
7

80
WA
L

60
RDH E0

RDH E2

RDH E4

Pb
pF

40
N

500 600 800 1000 1500 2000 3000 4000 5000 6000 8000 10000 m/h
Measured in installation B
0.2 0.3 0.4 0.5 0.6 0.8 1 1.4 2 3 m/s
qV according to ISO5801:

2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 4 6 8 10 20 40 60 80 100 200 400 600 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 4600 3 -8 -7 -5 -4 -4 -9 -13 -18 dB 6 7 3 -2 -4 -6 -8 -16 dB
SX 3200 3 -7 -3 -4 0 -8 -9 -13 -19 dB 9 7 3 0 -7 -4 -11 -18 dB
SX 2300 2 -4 -3 -3 -1 -6 -10 -15 -20 dB 10 6 2 -1 -3 -5 -13 -19 dB
qV opt 4600 4 -10 -10 -8 -8 -3 -7 -10 -17 dB 6 5 0 -5 -4 -3 -5 -15 dB
qV opt 3200 4 -9 -8 -7 -1 -7 -7 -12 -19 dB 7 4 -1 -2 -5 -1 -9 -18 dB
qV opt 2300 3 -8 -6 -7 -1 -5 -8 -15 -21 dB 6 2 -2 -2 -1 -3 -13 -20 dB
DX 4600 3 -10 -9 -9 -7 -5 -6 -9 -15 dB 5 4 -2 -4 -4 -2 -4 -13 dB
DX 3200 3 -7 -8 -8 -3 -6 -6 -10 -19 dB 7 3 -2 -2 -5 -1 -8 -16 dB
DX 2300 3 -7 -7 -8 -3 -4 -7 -13 -21 dB 6 1 -2 -3 -1 -3 -11 -19 dB

116
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0250

Dimensions in mm, subject to change.


RDH E0-0250 13.3 kg
485 232 195 198
322 423 426

22.5
6

7
6
9
20h7

304

322
268
322
30

467

488
215
130 28

161
322
11 16 2 176
352 378 = =
382 224
RDH E2-0250 15.7 kg
485 425 428
25 322 195 198
22.5

10
6

9
20h7

322
268
322
30

470

488
224
130 28

138
322
11 16 2 176
352 378 224
372 386 39
RDH E4-0250 21 kg
515 425 428
25 322 195 198

10
8
28
7

9
25h7

322
268
322
40
470

488
224

130 28
138

322
11 16 2 176
352 378 224
372 386 39

117
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0280 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 282 mm Impeller weight m 5,89 kg
Number of blades z 11 Density of media r1 1,2 kg/m
Moment of Inertia J 0,069 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt
Pa N all types suitable S.p.A certifies that
4500

67
%
N RDH E4 only kW the fan shown

55
4000 5.5
N do not use in this area 4.0 7.5 herein is licensed

76
r
3500 to bear the AMCA
3.0

72
3000 Seal.
The ratings shown
2500 are based on tests
2.0

61
and procedures performed in ac-
2000 1.5 cordance with AMCAPublication211
and comply with the requirements of
1500 1.0 the AMCA Certified Ratings Program.

45
The AMCA Certified Ratings Seal
0.8
applies to air performance ratings only.
0.6
1000

29
0.4 1/min W W W
800
5100 61 61 77
0.3
4700 56 56 71
600
r
P

0.2 4300 52 52 65
500
4000 48 48 60
400
3600 43 43 54

300 3200 38 38 48
95 dB
SX

2800 34 34 42
200 75
Normal operation area
90 2400 29 29 36
150
DX

2000 24 24 30
85
100
1800 22 22 27
80
7

1600 19 19 24
WA

80
L

60
RDH E0

RDH E2

RDH E4

Pb
pF

40
N

500 600 800 1000 1500 2000 3000 4000 5000 6000 8000 10000 m/h
Measured in installation B
0.2 0.3 0.4 0.5 0.6 0.8 1 1.4 2 3 m/s
qV according to ISO5801:

2 3 4 5 6 7 8 9 10 14 20 m/s
v2

0.8 1 2 3 4 5 7 10 20 40 60 80 100 200 400 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 4300 3 -8 -6 -5 -5 -4 -9 -12 -16 dB 7 7 3 -3 -4 -4 -8 -15 dB
SX 2800 3 -7 -4 -4 -1 -8 -8 -13 -18 dB 10 6 2 -1 -5 -3 -11 -17 dB
SX 1800 3 -1 -1 0 -4 -5 -8 -14 -19 dB 11 7 5 -3 0 -5 -13 -18 dB
qV opt 4300 4 -10 -9 -8 -8 -4 -7 -10 -15 dB 7 5 0 -6 -5 -2 -5 -14 dB
qV opt 2800 3 -9 -7 -7 -1 -7 -6 -12 -18 dB 7 3 -1 -3 -4 0 -10 -17 dB
qV opt 1800 4 -6 -5 -2 -5 -4 -7 -14 -20 dB 7 2 2 -4 1 -4 -13 -19 dB
DX 4300 3 -9 -9 -9 -8 -4 -6 -8 -14 dB 6 4 -1 -4 -3 -2 -4 -12 dB
DX 2800 4 -7 -8 -8 -3 -7 -5 -11 -18 dB 7 2 -2 -1 -4 0 -8 -16 dB
DX 1800 4 -6 -6 -3 -5 -4 -6 -14 -22 dB 7 2 3 -3 1 -3 -11 -19 dB

118
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0280

Dimensions in mm, subject to change.


RDH E0-0280 17.8 kg
555 261 215 218
361 471 474
8

28

6
7
9
25h7

242

361
302
361
40

524

546
242
130 28

183
361
11 16 2 195.5
391 417 = =
421 280
RDH E2-0280 21 kg
555 472 475
30 361 215 218
8

9
28
7

9
25h7

361
302
361
40

526

545
280
130 28

156
361
13 18 2 195.5
391 417 280
421 435 37
RDH E4-0280 28 kg
580 472 475
30 361 215 218
8

9
33
7

9
30h7

361
302
361
40
526

545
280

130 28
156

361
13 18 2 195.5
391 417 280
421 435 37

119
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0315 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 317 mm Impeller weight m 7,14 kg
Number of blades z 11 Density of media r1 1,2 kg/m
Moment of Inertia J 0,110 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area! NicotraGebhardt
Pa N all types suitable S.p.A certifies that
4500
N RDH E4/E6 only the fan shown

72
4000 kW

59
N RDH E6 only herein is licensed

77
3500 7.5
N do not use in this area r to bear the AMCA
3000 Seal.

73
5.5
The ratings shown
2500 are based on tests
4.0

63
and procedures performed in ac-
2000 3.0 cordance with AMCAPublication211
and comply with the requirements of
1500 2.0 the AMCA Certified Ratings Program.

48
The AMCA Certified Ratings Seal
1.5 applies to air performance ratings only.

1000
1.0

31
1/min W W W W
800 0.8
4500 54 54 68 225
0.6
600 105 dB 4100 49 49 62 205
r
P

500 0.4
3500 42 42 53 175
100
400
3100 37 37 47 155

300 2800 34 34 42 140


95
SX

2400 29 29 36 120
200
75
Normal operation area 90
150 2000 24 24 30 100
DX

1800 22 22 27 90
85
100
1600 19 19 24 80

80
7
WA

80 1400 17 17 21 70
L

60
RDH E0

RDH E2

RDH E4

RDH E6
Pb
pF

40
N

1000 1500 2000 3000 4000 5000 6000 8000 10000 15000 20000 m/h
Measured in installation B
0.3 0.4 0.5 0.6 0.8 1 1.4 2 3 4 5 6 7 m/s
qV according to ISO5801:

2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

2 3 4 5 7 10 20 40 60 80 100 200 400 600 800 1000 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 4100 4 -7 -5 -4 -4 -3 -11 -15 -18 dB 8 8 4 -1 -3 -6 -11 -17 dB
SX 2800 4 -7 -4 -4 -0 -6 -12 -14 -18 dB 11 7 3 -1 -3 -7 -12 -17 dB
SX 1600 3 0 -1 2 -2 -8 -10 -14 -18 dB 11 7 6 0 -2 -7 -13 -18 dB
qV opt 4100 4 -9 -9 -8 -6 -3 -11 -14 -18 dB 7 5 0 -3 -3 -6 -10 -16 dB
qV opt 2800 4 -9 -7 -7 -1 -8 -11 -13 -19 dB 7 3 -1 0 -4 -6 -11 -18 dB
qV opt 1600 4 -5 -5 0 -4 -7 -9 -14 -20 dB 7 2 4 -2 -1 -6 -13 -19 dB
DX 4100 3 -9 -9 -9 -7 -2 -10 -12 -16 dB 6 4 -2 -3 -1 -5 -8 -14 dB
DX 2800 3 -7 -8 -8 0 -7 -10 -12 -19 dB 6 2 -2 1 -3 -5 -9 -17 dB
DX 1600 3 -6 -5 0 -3 -6 -8 -15 -22 dB 6 2 5 -1 -1 -5 -12 -20 dB

120
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0315

Dimensions in mm, subject to change.


RDH E0-0315 21 kg
600 289 236 239
404 522 525
8

28

7
7
9
25h7

376

404
338
403
40

586

607
267
130 28

202
404
11 16 2 217
434 460 = =
464 280
RDH E2-0315 25 kg
600 524 527
30 404 236 239
8

10
28
7

9
25h7

404
338
403
40

588

606
280
130 28

175
404
13 18 2 217
434 460 280
464 486 38
RDH E4-0315 32 kg
625 524 527
30 404 236 239

10
8
33
7

9
30h7

404
338
403
40
588

606
280

130 28
175

404
13 18 2 217
434 460 280
464 486 38
RDH E6-0315 34 kg
625 524 527
30 404 236 239
10

8
33
7

9
30h7
404
338
403

40
588

606
280

130 28
175

404
13 18 2 217
434 460 280
464 486 38

121
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0355 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 357 mm Impeller weight m 10,2 kg
Number of blades z 11 Density of media r1 1,2 kg/m
Moment of Inertia J 0,200 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt
Pa N all types suitable S.p.A certifies that

70
4500

54
N RDH E4/E6 only the fan shown
4000 11

77
N RDH E6 only 15 r herein is licensed
3500 kW
N do not use in this area to bear the AMCA
7.5

73
3000 Seal.
5.5 The ratings shown
2500 are based on tests

62
4.0 and procedures performed in ac-
2000 cordance with AMCAPublication211
3.0 and comply with the requirements of

47
1500 the AMCA Certified Ratings Program.
2.0 The AMCA Certified Ratings Seal
applies to air performance ratings only.
1.5

31
1000
1/min W W W W
1.0 4200 63 63 71 260
800
0.8 4000 60 60 68 248
3800 57 57 65 236
600 0.6 105 dB

500 3300 50 50 56 205


0.4
r
P

400
0.3 100 2800 42 42 48 174

300
2400 36 36 41 149
95
SX

200
2000 30 30 34 124
Normal operation area 75 90
150 1800 27 27 31 112

1600 24 24 27 99
DX

85
100
1400 21 21 24 87
80
7
WA

80
L

1200 18 18 20 74
60
RDH E0

RDH E2

RDH E4

RDH E6
Pb
pF

40
N

1000 1500 2000 3000 4000 5000 6000 8000 10000 15000 20000 m/h
Measured in installation B
0.3 0.4 0.5 0.6 0.8 1 1.4 2 3 4 5 6 7 m/s
qV according to ISO5801:

1.4 2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 3 4 5 7 10 20 40 60 80 100 200 400 600 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 3800 5 -7 -5 -4 -2 -6 -11 -14 -17 dB 11 9 5 1 -5 -6 -10 -16 dB
SX 2400 4 -5 -3 -3 -1 -7 -12 -14 -18 dB 11 7 4 0 -3 -7 -12 -17 dB
SX 1400 4 0 0 3 -3 -7 -9 -14 -18 dB 11 7 7 0 -2 -7 -13 -18 dB
qV opt 3800 6 -9 -8 -7 -3 -5 -10 -12 -17 dB 9 7 2 0 -4 -4 -9 -15 dB
qV opt 2400 4 -8 -7 -7 -1 -6 -11 -13 -18 dB 7 3 -1 -1 -2 -6 -11 -17 dB
qV opt 1400 4 -4 -4 2 -3 -7 -9 -14 -19 dB 7 2 6 0 -1 -6 -13 -19 dB
DX 3800 4 -8 -8 -8 -3 -5 -9 -11 -17 dB 7 4 -1 0 -3 -4 -8 -14 dB
DX 2400 3 -7 -8 -8 0 -6 -10 -13 -20 dB 6 1 -2 1 -2 -6 -10 -17 dB
DX 1400 3 -5 -5 2 -3 -6 -9 -16 -22 dB 5 2 7 0 -1 -6 -13 -20 dB

122
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0355

Dimensions in mm, subject to change.


RDH E0-0355 29 kg
675 327 261 264
453 582 585
8

33

7
7
9
30h7

418

453
381
450
40

658

679
281
130 28

212
453
11 16 2 241.5
493 509 = =
533 355
RDH E2-0355 34 kg
675 586 589
40 453 261 264
8

13
33
7

9
30h7

453
381
450
40

665

680
355
130 28

202
453
13 18 2 241.5
493 509 355
533 547 39
RDH E4-0355 46 kg
685 586 589
40 453 261 264

13
10
38
8

9
35h7

453
381
450
50
665

680
355

130 28
202

453
13 18 2 241.5
493 509 355
533 547 39
RDH E6-0355 47 kg
685 586 589
40 453 261 264
13

10
38
8

9
35h7
453
381
450

50
665

680
355

130 28
202

453
13 18 2 241.5
493 509 355
533 547 39

123
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0400 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 402 mm Impeller weight m 12,7 kg
Number of blades z 11 Density of media r1 1,2 kg/m
Moment of Inertia J 0,330 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt
Pa

%
N all types suitable S.p.A certifies that

71
58
4500 kW 15
N RDH E4/E6 only 18.5 the fan shown
11

78
4000
N RDH E6 only r herein is licensed
3500 N do not use in this area to bear the AMCA

74
7.5 Seal.
3000
The ratings shown
2500 are based on tests

63
5.0
and procedures performed in ac-
2000 4.0
cordance with AMCAPublication211
3.0 and comply with the requirements of

46
1500 the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal
2.0
applies to air performance ratings only.
1.5
1000

30
1/min W W W W
800 1.0 3800 57 57 65 236
0.8 3500 53 53 60 217
r
P

600 0.6
105 dB 3100 47 47 53 192
500
2900 44 44 49 180
0.4
400 2700 41 41 46 167

100 2400 36 36 41 149


300
SX

75 2200 33 33 37 136

95 2000 30 30 34 124
Normal operation area
200
1800 27 27 31 112

150 80
1600 24 24 27 99
DX

90

1400 21 21 24 87
7
WA

100 85
L

80 1200 18 18 20 74

60
RDH E0

RDH E2

RDH E4

RDH E6
Pb
pF

40
N

1500 2000 3000 4000 5000 6000 8000 10000 15000 20000 30000 m/h
Measured in installation B
0.5 0.6 0.8 1 1.4 2 3 4 5 6 7 8 9 10 m/s
qV according to ISO5801:

2 3 4 5 6 7 8 9 10 14 20 30 40 m/s
v2

2 3 4 5 7 10 20 40 60 80 100 200 400 600 800 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 3100 3 -7 -3 -4 -1 -6 -10 -11 -16 dB 10 7 3 -1 -4 -4 -8 -15 dB
SX 2400 3 -5 -3 -3 -1 -6 -8 -13 -17 dB 10 6 2 -2 -2 -4 -11 -16 dB
SX 1400 3 0 0 3 -3 -6 -9 -13 -17 dB 10 6 6 0 -1 -7 -12 -16 dB
qV opt 3100 3 -9 -7 -7 -1 -6 -9 -10 -17 dB 7 4 -1 0 -4 -3 -8 -15 dB
qV opt 2400 3 -8 -7 -7 -1 -6 -8 -13 -18 dB 10 7 3 0 -2 -3 -11 -17 dB
qV opt 1400 3 -4 -4 2 -4 -5 -8 -14 -18 dB 6 2 6 -1 0 -6 -13 -18 dB
DX 3100 2 -7 -8 -8 -1 -7 -9 -10 -17 dB 6 2 -2 0 -4 -4 -7 -15 dB
DX 2400 3 -7 -8 -8 0 -7 -8 -12 -20 dB 5 0 -3 0 -4 -3 -10 -17 dB
DX 1400 3 -5 -5 2 -4 -5 -8 -15 -21 dB 5 1 6 -1 -1 -5 -13 -19 dB

124
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0400

Dimensions in mm, subject to change.


RDH E0-0400 36 kg
725 366 290 293
507 654 657
8

33

7
7
9
30h7

469

507
432
507
40

745

766
200

309
130 28

234
507
11 16 537
547 563 = =
587 355
RDH E2-0400 42 kg
725 657 660
40 507 290 293
8

11
33
7

9
30h7

507
432
507
40

750

767
355
200
130 28

232
507
13 18 537
547 563 355
587 614 43
RDH E4-0400 57 kg
750 657 660
40 507 290 293

11
10
38
8

9
35h7

507
432
507
50
750

767
355

200
130 28
232

507
13 18 537
547 563 355
587 614 43
RDH E6-0400 58 kg
750 657 660
40 507 290 293
11

10
38
8

9
35h7
507
432
507

50
750

767
355

200
130 28
232

507
13 18 537
547 563 355
587 614 43

125
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0450 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 452 mm Impeller weight m 17,6 kg
Number of blades z 11 Density of media r1 1,2 kg/m
Moment of Inertia J 0,520 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt
Pa N all types suitable S.p.A certifies that

%
4500 kW

68
51
N RDH E4/E6 only 22 the fan shown
4000 15

78
N RDH E6 only r herein is licensed
3500 N do not use in this area to bear the AMCA
11

74
3000 Seal.
The ratings shown
2500 7.5
are based on tests

61
and procedures performed in ac-
2000 5.0 cordance with AMCAPublication211
4.0 and comply with the requirements of
the AMCA Certified Ratings Program.

45
1500
3.0 The AMCA Certified Ratings Seal
applies to air performance ratings only.
2.0
1000
1/min W W W W

30
1.5
800 3400 58 58 71 272
3200 54 54 67 256
1.0
600 0.8 2800 48 48 59 224
105 dB
500
r
P

0.6
2500 43 43 52 200
400
0.4
100 2200 37 37 46 176
300 2000 34 34 42 160
SX

95 1800 31 31 38 144
200
Normal operation area 75 1600 27 27 34 128

150 90
1400 24 24 29 112
DX

85 1200 20 20 25 96
100
1100 17 17 21 80
80
7

1000 17 17 21 80
WA

80
L

60
RDH E0

RDH E2

RDH E4

RDH E6
Pb
pF

40
N

1500 2000 3000 4000 5000 6000 8000 10000 15000 20000 30000 m/h
Measured in installation B
0.5 0.6 0.8 1 1.4 2 3 4 5 6 7 8 9 10 m/s
qV according to ISO5801:

1.4 2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 3 4 5 7 10 20 40 60 80 100 200 400 600 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 2800 3 -7 -4 -4 0 -7 -10 -13 -17 dB 10 6 2 0 -4 -5 -11 -16 dB
SX 2000 3 -3 -2 -1 -1 -6 -10 -13 -19 dB 10 6 3 0 -2 -6 -12 -18 dB
SX 1200 3 1 0 3 -3 -7 -10 -15 -20 dB 6 0 0 1 -2 -8 -14 -20 dB
qV opt 2800 3 -9 -7 -7 -1 -6 -9 -12 -17 dB 6 2 -2 -2 -3 -3 -10 -16 dB
qV opt 2000 3 -7 -5 -4 -1 -5 -9 -13 -19 dB 6 2 0 -2 0 -5 -12 -19 dB
qV opt 1200 3 -4 -4 3 -2 -6 -10 -15 -21 dB 6 2 6 2 -1 -8 -15 -21 dB
DX 2800 3 -7 -8 -8 0 -7 -9 -13 -19 dB 6 1 -3 1 -4 -4 -10 -17 dB
DX 2000 3 -7 -6 -5 -1 -6 -9 -14 -21 dB 6 0 0 0 -1 -5 -12 -19 dB
DX 1200 3 -5 -5 3 -3 -6 -10 -17 -24 dB 4 1 6 1 -2 -8 -15 -22 dB

126
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0450

Dimensions in mm, subject to change.


RDH E0-0450 50 kg
815 415 322 325
569 732 735
10

38

7
8
9
35h7

526

569
487
571
50

838

859
200

344
130 28

260
569
13 18 599
619 625 = =
665 530
RDH E2-0450 57 kg
815 733 736
40 569 322 325
10

11
38
8

9
35h7

569
487
571
50

841

858
530
200
130 28

259
569
13 18 599
619 625 530
649 687 46
RDH E4-0450 73 kg
850 733 736
40 569 322 325

11
12
43
8

9
40h7

569
487
571
70
841

858
530

200
130 28
259

569
13 18 599
619 625 530
649 687 46
RDH E6-0450 75 kg
850 733 736
40 569 322 325
11

12
43
8

9
40h7
569
487
571

70
841

858
530

200
130 28
259

569
13 18 599
619 625 530
649 687 46

127
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0500 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 502 mm Impeller weight m 23,5 kg
Number of blades z 11 Density of media r1 1,2 kg/m
Moment of Inertia J 0,890 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt
Pa N all types suitable S.p.A certifies that

%
4500

69
N RDH E4/E6/E7 only the fan shown

51
kW 22

80
4000
N RDH E6/E7 only 15 r herein is licensed
3500 N RDH E7 only to bear the AMCA

75
3000 N do not use in this area 11 Seal.
The ratings shown
2500 8.0 are based on tests

62
and procedures performed in ac-
2000 6.0
cordance with AMCAPublication211
and comply with the requirements of
4.0 the AMCA Certified Ratings Program.

45
1500
The AMCA Certified Ratings Seal
3.0 applies to air performance ratings only.

1000 2.0

29
1/min W W W W
800 1.5
3000 51 63 240 439
2800 48 59 224 410
r
P

600 1.0 2650 45 56 212 388


0.8
500 105 dB
2350 40 49 188 344
0.6
400
2100 36 44 168 307

100
300
1800 31 38 144 263
SX

95 1600 27 34 128 234


200
Normal operation area
1400 24 29 112 205
150 90
DX

1200 20 25 96 176

100
85
1000 17 21 80 146
80
80
7
WA

900 15 19 72 132
L

60
RDH E0/E2

RDH E4

RDH E6

RDH E7
Pb
pF

40
N

2000 3000 4000 5000 6000 8000 10000 15000 20000 30000 40000 m/h
Measured in installation B
0.6 0.8 1 1.4 2 3 4 5 6 7 8 9 10 14 m/s
qV according to ISO5801:

1.4 2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 3 4 5 7 10 20 40 60 80 100 200 400 600 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 2600 2 -6 -4 -4 1 -9 -13 -14 -18 dB 9 5 1 1 -6 -8 -13 -17 dB
SX 1800 3 -1 -1 0 -2 -9 -11 -15 -18 dB 10 6 4 0 -4 -8 -13 -18 dB
SX 1000 3 2 2 2 -5 -7 -11 -14 -18 dB 10 7 5 0 -3 -9 -13 -18 dB
qV opt 2600 1 -9 -7 -8 1 -9 -12 -14 -19 dB 8 5 1 1 -5 -7 -12 -18 dB
qV opt 1800 2 -6 -5 -2 -1 -8 -10 -15 -19 dB 10 6 4 0 -3 -7 -13 -18 dB
qV opt 1000 3 -2 -1 2 -4 -7 -11 -15 -19 dB 5 3 5 1 -3 -9 -14 -19 dB
DX 2600 2 -8 -8 -8 1 -7 -11 -13 -19 dB 5 0 -3 1 -4 -6 -10 -16 dB
DX 1800 3 -6 -6 -3 -1 -7 -9 -14 -19 dB 6 1 2 0 -2 -6 -12 -17 dB
DX 1000 3 -3 -2 2 -3 -6 -10 -15 -21 dB 5 4 5 1 -3 -8 -13 -20 dB

128
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0500

Dimensions in mm, subject to change.


RDH E0-0500 62 kg
885 456 352 355
638 805 808
10

38

7
8
9
35h7

576

638
541
641
50

928

949
250

383
130 28

283
638
13 18 668
688 694 = =
734 530
RDH E2-0500 70 kg
885 807 810
40 638 352 355
10

10
38
8

9
35h7

638
541
641
50

931

949
530
250
130 28

280
638
13 18 668
688 694 530
718 756 51
RDH E4-0500 90 kg
920 807 810
40 638 352 355

10
12
43
8

9
40h7

638
541
641
70
931

949
530

250
130 28
280

638
13 18 668
688 694 530
718 756 51
RDH E6-0500 92 kg
920 807 810
40 638 352 355
10

12
43
8

9
40h7
638
541
641

70
931

949
530

250
130 28
280

638
13 18 668
688 694 530
718 756 51
RDH E7-0500 110 kg
960 807 810
40 638 352 355
53.5

10

14
9

9
50h7
638
541
641

90
931

949
530

250
130 28
280

638
13 18 668
688 694 530
718 756 51

129
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0560 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 562 mm Impeller weight m 28,8 kg
Number of blades z 11 Density of media r1 1,2 kg/m
Moment of Inertia J 1,410 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt

70
Pa N all types suitable kW S.p.A certifies that

50
4500 30 37

81
N RDH E4/E6/E7 only 25 the fan shown
4000
N RDH E6/E7 only r
herein is licensed
18.5

76
3500 N RDH E7 only to bear the AMCA
3000 N do not use in this area 15 Seal.
The ratings shown

63
2500 are based on tests
10
and procedures performed in ac-
2000 8.0
cordance with AMCAPublication211
6.0 and comply with the requirements of

46
1500 the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal
4.0
applies to air performance ratings only.
3.0
1000

30
1/min W W W W
2800 59 140 350 355
800 2.0
2600 55 130 325 330
1.5 110 dB
r
P

2400 50 120 300 305


600

500 1.0
2100 44 105 263 267
0.8
105 1950 41 98 244 247
400
0.6 1800 38 90 225 228

300 100 1600 34 80 200 203


SX

1400 29 70 175 178


200 Normal operation area 95

1200 25 60 150 152


150
80
DX

90
1000 21 50 125 127
100
7

85
WA

80
L

800 17 40 100 102


60
RDH E0/E2

RDH E4

RDH E6

RDH E7
Pb
pF

40
N

3000 4000 5000 6000 8000 10000 15000 20000 30000 40000 60000 m/h
Measured in installation B
0.8 1 1.4 2 3 4 5 6 7 8 9 10 14 m/s
qV according to ISO5801:

1.4 2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 3 4 5 7 10 20 40 60 80 100 200 400 600 Pa


pd2

Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 2400 3 -5 -3 -3 -1 -7 -12 -13 -15 dB 10 6 2 0 -3 -7 -11 -14 dB
SX 1800 3 -1 -1 0 -1 -8 -10 -12 -16 dB 6 1 -2 0 -3 -7 -11 -15 dB
SX 1000 3 2 2 2 -4 -7 -9 -12 -18 dB 10 7 5 0 -3 -7 -11 -19 dB
qV opt 2400 3 -8 -7 -7 -1 -6 -11 -11 -14 dB 6 2 -2 -2 -2 -6 -10 -13 dB
qV opt 1800 3 -1 -1 0 -2 -7 -9 -11 -14 dB 6 2 2 -1 -2 -6 -10 -14 dB
qV opt 1000 3 -2 -1 2 -4 -7 -8 -11 -17 dB 5 4 5 1 -2 -7 -10 -17 dB
DX 2400 2 -7 -8 -8 1 -7 -11 -13 -16 dB 5 0 -3 1 -3 -7 -11 -14 dB
DX 1800 3 -6 -6 -3 -1 -7 -10 -13 -15 dB 6 1 2 1 -2 -7 -11 -13 dB
DX 1000 3 -3 -2 2 -4 -7 -10 -12 -16 dB 4 4 6 1 -3 -7 -10 -15 dB

130
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH E_-0560

Dimensions in mm, subject to change.


RDH E0-0560 79 kg
1000 511 390 393
715 897 900
12

43

7
8
9
40h7

643

715
606
716
70

1037

1058
250

425
130 28

315
715
13 18 745
765 771 = =
811 530
RDH E2-0560 92 kg
1000 901 904
50 715 390 393
12

13
43
8

9
40h7

715
606
716
70

1046

1061
530
250
130 28

317
715
13 18 745
765 771 530
815 851 50
RDH E4-0560 141 kg
1070 901 904
50 715 390 393
53.5

13
14
9

9
50h7

715
606
716
90
1046

1061
530

250
130 28
317

715
13 18 745
765 771 530
815 851 50
RDH E6-0560 148 kg
1070 901 904
50 715 390 393
53.5

13

14
9

9
50h7
715
606
716

90
1046

1061
530

250
130 28
317

715
13 18 745
765 771 530
815 851 50
RDH E7-0560 153 kg
1130 901 904
50 715 390 393
53.5

13

14
9

9
50h7
715
606
716

90
1046

1061
530

250
130 28
317

715
13 18 745
765 771 530
815 851 50

131
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH _-0630 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 632 mm Impeller weight m 36,7 kg
Number of blades z 11 Density of media r1 1,2 kg/m
Moment of Inertia J 2,320 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt
Pa N all types suitable S.p.A certifies that

69
4500 N RDH K/K1/K2 only kW 45

49
the fan shown

82
4000 30
N RDH K1/K2 only r herein is licensed
3500 N RDH K2 only 25 to bear the AMCA

77
3000 N do not use in this area Seal.
18.5
The ratings shown
2500 15 are based on tests

63
and procedures performed in ac-
2000 10 cordance with AMCAPublication211
and comply with the requirements of
8.0

46
the AMCA Certified Ratings Program.
1500
6.0 The AMCA Certified Ratings Seal
applies to air performance ratings only.

4.0
1000

30
1/min W W W W
3.0 2500 52 125 313 317
800
2300 48 115 288 292
2.0
600
1.5 2000 42 100 250 254
500
r
P

400 1.0
1700 36 85 213 216
0.8 1600 34 80 200 203
300 100 dB
1400 29 70 175 178
SX

95
200 1200 25 60 150 152
Normal operation area

150
90 1000 21 50 125 127
DX

900 19 45 113 114


100
85
800 17 40 100 102
80
7
WA

80 700 15 35 88 89
L

60
RDH K1

RDH K2
RDH R

RDH K

Pb
pF

40
N

3000 4000 5000 6000 8000 10000 15000 20000 30000 40000 60000 m/h
Measured in installation B
1 2 3 4 5 6 7 8 9 10 14 20 m/s according to ISO5801:
qV
2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 3 4 5 7 10 20 40 60 80 100 200 400 600 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 2000 3 3 3 1 -1 -7 -12 -15 -18 dB 14 11 4 0 -2 -8 -14 -18 dB
SX 1400 3 5 4 3 -1 -8 -12 -16 -18 dB 14 10 4 2 -3 -9 -15 -18 dB
SX 800 3 8 7 3 -4 -7 -12 -13 -21 dB 15 8 6 2 -4 -11 -13 -21 dB
qV opt 2000 3 0 -1 -2 -1 -6 -11 -14 -17 dB 9 6 1 0 -1 -7 -13 -17 dB
qV opt 1400 3 2 -2 3 -2 -7 -11 -15 -17 dB 10 5 2 2 -1 -9 -14 -17 dB
qV opt 800 3 3 6 3 -3 -7 -11 -13 -20 dB 9 6 5 3 -4 -10 -12 -20 dB
DX 2000 3 -4 -4 -2 -1 -6 -11 -13 -19 dB 10 4 2 1 -1 -7 -11 -17 dB
DX 1400 3 -2 -3 2 -1 -7 -10 -16 -21 dB 8 4 4 2 -2 -8 -13 -19 dB
DX 800 3 1 6 3 -3 -6 -11 -16 -21 dB 8 8 5 2 -3 -8 -14 -22 dB

132
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH _-0630

Dimensions in mm, subject to change.


RDH R-0630 119 kg
1085 996 999
50 801 70 434 437
12

43
8
9
40h7

801
679
801
70

1157

1178
530
300
130 28

349
801
13 18 831
851 857 530
901 940 56
RDH K-0630 173 kg
1155 999 1002
50 801 434 437
53.5

14
9

9
50h7

801
679
801
90

1157

1179
530
300
130 28

350
801
13 18 831
851 857 530
901 940 59
RDH K1-0630 180 kg
1155 999 1002
50 801 434 437
53.5

14
9

9
50h7

801
679
801
90
1157

1179
530

300
130 28
350

801
13 18 831
851 857 530
901 940 59
RDH K2-0630 185 kg
1215 999 1002
50 801 434 437
53.5

14
9

9
50h7
801
679
801

90
1157

1179
530

300
130 28
350

801
13 18 831
851 857 530
901 940 59

133
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH _-0710 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 712 mm Impeller weight m 60 kg
Number of blades z 11 Density of media r1 1,2 kg/m
Moment of Inertia J 4,940 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt
Pa N all types suitable S.p.A certifies that

71
55

50
4500 N RDH K/K1/K2 only 45 the fan shown

83
4000 37
N RDH K1/K2 only r herein is licensed
kW

78
3500 N RDH K2 only to bear the AMCA
3000 N do not use in this area 25 Seal.
22 The ratings shown

64
2500 are based on tests
15 and procedures performed in ac-
2000 cordance with AMCAPublication211
and comply with the requirements of
10

46
the AMCA Certified Ratings Program.
1500 8.0 The AMCA Certified Ratings Seal
applies to air performance ratings only.
6.0

1000 1/min W W W W

30
4.0
2200 110 110 372 129
800
3.0
2000 100 100 338 117
r
P

600 2.0
1700 85 85 287 100
500 1.5
105 dB
400 1500 75 75 254 88
SX

300 100 1300 65 65 220 76


1200 60 60 203 70
Normal operation area 80 1100 55 55 186 64
200 95
1000 50 50 169 59
DX

150 900 45 45 152 53


90
800 40 40 135 47
100
7

700 35 35 118 41
WA

85
L

80

60
RDH K1

RDH K2
RDH R

RDH K

Pb
pF

40
N

5000 6000 8000 10000 15000 20000 30000 40000 60000 80000 m/h
Measured in installation B
1.4 2 3 4 5 6 7 8 9 10 14 20 m/s according to ISO5801:
qV
1.5 2 3 4 5 6 7 8 9 10 12 14 20 30 m/s
v2

2 4 6 8 10 20 40 60 80 100 200 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 2000 3 1 1 0 0 -8 -11 -14 -19 dB 11 8 3 1 -3 -7 -13 -19 dB
SX 1500 3 3 2 3 -2 -8 -10 -15 -19 dB 11 8 4 1 -3 -7 -14 -19 dB
SX 800 3 6 7 3 -4 -6 -11 -15 -19 dB 12 8 5 1 -3 -10 -15 -19 dB
qV opt 2000 3 -1 -1 -1 -0 -7 -10 -14 -19 dB 7 6 2 0 -2 -6 -13 -18 dB
qV opt 1500 3 0 0 3 -3 -7 -9 -15 -19 dB 8 6 3 0 -2 -7 -14 -19 dB
qV opt 800 3 4 7 2 -4 -6 -11 -15 -20 dB 10 7 4 2 -3 -10 -15 -20 dB
DX 2000 3 -1 -1 -1 0 -8 -10 -14 -21 dB 12 7 3 1 -3 -6 -12 -19 dB
DX 1500 3 1 0 4 -3 -8 -9 -16 -22 dB 11 7 6 0 -2 -7 -14 -21 dB
DX 800 3 4 7 2 -4 -5 -12 -18 -23 dB 11 9 4 2 -2 -10 -16 -23 dB

134
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH _-0710

Dimensions in mm, subject to change.


RDH R-0710 165 kg
1255 1117 1120
50 898 90 485 488

53.5
14

9
9
50h7

898
765
898
90

1303

1324
630
400
130 28

398
898
17 22 928
948 954 630
998 1050 67
RDH K-0710 220 kg
1255 1121 1123
50 898 485 488
53.5

14
9

9
50h7

898
765
898
90

1303

1324
630
400
130 28

398
898
17 22 928
948 954 630
998 1050 71
RDH K1-0710 240 kg
1340 1121 1123
50 898 485 488
18
11
64

9
60h7

898
765
898
90
1303

1324
630

400
130 28
398

898
17 22 928
948 954 630
998 1050 71
RDH K2-0710 250 kg
1340 1121 1123
50 898 485 488
18
11
64

9
60h7
898
765
898

90
1303

1324
630

400
130 28
398

898
17 22 928
948 954 630
998 1050 71

135
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH _-0800 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 802 mm Impeller weight m 86 kg
Number of blades z 11 Density of media r1 1,2 kg/m
Moment of Inertia J 8,250 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt
Pa N all types suitable S.p.A certifies that
4500 N RDH K1/K2 only the fan shown

71
%
4000 N RDH K2 only herein is licensed

50
45 55

83
3500 N do not use in this area 37 to bear the AMCA
kW r
Seal.

78
3000
The ratings shown
2500 22 are based on tests
and procedures performed in ac-

64
2000 15 cordance with AMCAPublication211
and comply with the requirements of
11 the AMCA Certified Ratings Program.
1500

46
The AMCA Certified Ratings Seal
8.0 applies to air performance ratings only.
6.0
1000

30
4.0 1/min W W W
800
1800 90 304 105
3.0
r
P

1650 83 279 97

2.0
1400 70 237 82
1.5
400 105 dB
1300 65 220 76
1200 60 203 70
300
SX

100 1100 55 186 64

Normal operation area 1000 50 169 58


200 80
95 900 45 152 53
DX

150 800 40 135 47

90
700 35 118 41
100
7
WA

85 600 30 101 35
L

80

60
RDH K1

RDH K2
RDH K

Pb
pF

40
N

5000 6000 8000 10000 15000 20000 30000 40000 60000 80000 100000 m/h
Measured in installation B
2 3 4 5 6 7 8 9 10 14 20 30 m/s according to ISO5801:
qV
2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 600 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1400 3 4 3 3 -2 -8 -10 -16 -19 dB 12 8 4 1 -3 -8 -15 -19 dB
SX 1100 3 5 3 4 -4 -8 -10 -16 -19 dB 12 6 5 1 -3 -8 -15 -20 dB
SX 700 3 7 8 2 -4 -6 -12 -15 -20 dB 12 8 5 1 -3 -11 -15 -19 dB
qV opt 1400 3 0 0 4 -3 -7 -9 -15 -20 dB 8 6 3 0 -2 -7 -14 -19 dB
qV opt 1100 3 1 0 4 -3 -7 -10 -16 -20 dB 8 3 4 1 -2 -9 -15 -21 dB
qV opt 700 3 4 8 1 -3 -6 -12 -16 -20 dB 9 7 4 2 -3 -10 -15 -20 dB
DX 1400 3 2 0 4 -3 -7 -9 -17 -23 dB 11 7 5 0 -2 -7 -14 -21 dB
DX 1100 3 2 0 5 -4 -7 -10 -18 -23 dB 10 4 6 1 -3 -8 -16 -22 dB
DX 700 3 4 8 1 -3 -5 -12 -18 -23 dB 11 9 4 2 -3 -10 -17 -23 dB

136
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH _-0800

Dimensions in mm, subject to change.


RDH K-0800 270 kg
1360 1255 1258
50 1007 540 543

53.5
14

9
9
50h7

1007
862
1007
90

1468

1489
710
500
130 28

454
1007
17 22 1037
1057 1063 710
1107 1181 74
RDH K1-0800 297 kg
1450 1255 1258
50 1007 540 543
18
11
64

9
60h7

1007
862
1007
90

1468

1489
710
500
130 28

454
1007
17 22 1037
1057 1063 710
1107 1181 74
RDH K2-0800 305 kg
1450 1255 1258
50 1007 540 543
18
11
64

9
60h7

1007
862
1007
90
1468

1489
710

500
130 28
454

1007
17 22 1037
1057 1063 710
1107 1181 74

137
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH _-0900 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 902 mm Impeller weight m 102 kg
Number of blades z 11 Density of media r1 1,2 kg/m
Moment of Inertia J 12,80 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt
kW

%
Pa N all types suitable S.p.A certifies that

71
50
4500 75
N RDH K1/K2 only 60 the fan shown

83
4000
N RDH K2 only r herein is licensed
45

78
3500 N do not use in this area to bear the AMCA
3000 Seal.
30 The ratings shown

65
2500 are based on tests
and procedures performed in ac-
20
2000 cordance with AMCAPublication211
15 and comply with the requirements of

47
the AMCA Certified Ratings Program.
1500
The AMCA Certified Ratings Seal
10
applies to air performance ratings only.
8.0

30
1000 1/min W W W
6.0
1750 140 296 103
800
4.0
1500 120 254 88
r
P

600 3.0

500
2.0 1250 100 211 73
400 105 dB
1.5
1100 88 186 64

300 1000 80 169 59


100
SX

900 72 152 53

200
Normal operation area 800 64 135 47
95
80
150
700 56 118 41
DX

90
600 48 101 35
100
7

85
WA

80
L

500 40 85 29

60
RDH K1

RDH K2
RDH K

Pb
pF

40
N

6000 8000 10000 15000 20000 30000 40000 60000 80000 100000 150000 m/h
Measured in installation B
2 3 4 5 6 7 8 9 10 14 20 30 m/s according to ISO5801:
qV
2 3 4 5 6 7 8 9 10 14 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 600 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1250 3 4 2 4 -3 -8 -10 -16 -19 dB 11 7 4 1 -3 -8 -15 -19 dB
SX 1000 3 5 4 4 -4 -7 -10 -16 -19 dB 12 7 5 1 -3 -9 -15 -19 dB
SX 600 3 6 8 1 -4 -6 -12 -15 -20 dB 10 9 5 1 -4 -11 -15 -20 dB
qV opt 1250 3 1 -1 4 -3 -7 -10 -16 -20 dB 8 4 4 1 -2 -8 -15 -20 dB
qV opt 1000 3 3 3 4 -4 -6 -10 -15 -20 dB 9 5 4 2 -2 -9 -15 -20 dB
qV opt 600 3 3 8 1 -3 -6 -12 -16 -21 dB 8 8 5 2 -4 -11 -16 -21 dB
DX 1250 3 1 -1 5 -4 -7 -10 -18 -24 dB 10 5 6 0 -3 -7 -15 -22 dB
DX 1000 3 3 3 4 -4 -6 -11 -18 -23 dB 10 7 5 1 -2 -8 -16 -22 dB
DX 600 3 4 9 1 -3 -6 -14 -19 -24 dB 9 10 5 2 -3 -11 -18 -24 dB

138
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH _-0900

Dimensions in mm, subject to change.


RDH K-0900 343 kg
1520 1408 1411
50 1130 604 607
18

11
64
9
60h7

1130
971
1130
90

1648

1669
800
600
130 28

511
1130
17 22 1160
1180 1186 800
1230 1319 89
RDH K1-0900 355 kg
1520 1408 1411
50 1130 604 607
18
11
64

9
60h7

1130
971
1130
90

1648

1669
800
600
130 28

511
1130
17 22 1160
1180 1186 800
1230 1319 89
RDH K2-0900 375 kg
1570 1408 1411
50 1130 604 607
18
11
64

9
60h7

1130
971
1130
90
1648

1669
800

600
130 28
511

1130
17 22 1160
1180 1186 800
1230 1319 89

139
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH _-1000 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data
Impeller diameter Dr 1002 mm Impeller weight m 146 kg
Number of blades z 11 Density of media r1 1,2 kg/m
Moment of Inertia J 24,80 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt
Pa N all types suitable S.p.A certifies that
4500 N RDH K2 only the fan shown
4000 N do not use in this area herein is licensed
kW

71
%
75
60

50
3500 50 to bear the AMCA

83
r
3000 Seal.
37 The ratings shown

79
2500 are based on tests
25
and procedures performed in ac-

65
2000 cordance with AMCAPublication211
20 and comply with the requirements of
the AMCA Certified Ratings Program.
1500 15
The AMCA Certified Ratings Seal

47
applies to air performance ratings only.
10
1000 8.0

800 6.0 1/min W W W

30
1400 112 237 82
4.0 1300 104 220 76
600
r
P

500 3.0
1150 92 195 67

400
105 dB 1000 80 169 58

300
100
SX

800 64 136 47

200
Normal operation area 95 700 56 119 41
80
150
DX

600 48 102 35
90
100
500 40 85 29
7
WA

80 85
L

450 36 76 26

60
RDH K1

RDH K2
RDH K

Pb
pF

40
N

6000 8000 10000 15000 20000 30000 40000 60000 80000 100000 150000 m/h
Measured in installation B
2 3 4 5 6 7 8 9 10 14 20 30 m/s according to ISO5801:
qV
1.4 2 3 4 5 6 7 8 9 10 14 20 m/s
v2

1 2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
LWrel4(A) centre frequencies fc octave centre frequencies fc
Duty Speed
point dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
1/min
SX 1150 3 4 2 4 -4 -8 -10 -16 -19 dB 12 6 5 1 -3 -8 -15 -20 dB
SX 800 3 7 7 3 -4 -6 -11 -15 -19 dB 12 8 5 1 -3 -10 -15 -19 dB
SX 500 3 8 8 0 -3 -6 -11 -15 -20 dB 11 9 5 1 -5 -11 -15 -20 dB
qV opt 1150 3 1 -1 4 -3 -7 -10 -16 -20 dB 8 3 4 1 -3 -8 -15 -21 dB
qV opt 800 3 4 7 2 -4 -5 -11 -15 -20 dB 10 7 4 2 -3 -10 -15 -20 dB
qV opt 500 3 7 7 0 -2 -6 -12 -16 -21 dB 9 8 6 2 -5 -11 -16 -20 dB
DX 1150 3 2 -1 5 -4 -7 -10 -18 -24 dB 10 4 6 0 -3 -8 -16 -22 dB
DX 800 3 4 7 2 -4 -5 -12 -18 -23 dB 11 9 4 1 -3 -10 -16 -23 dB
DX 500 3 7 8 1 -2 -6 -13 -19 -23 dB 11 9 5 2 -4 -11 -18 -24 dB

140
Belt Driven Centrifugal Fans / RDH / Technical Data

RDH _-1000

Dimensions in mm, subject to change.


RDH K-1000 415 kg
1660 1541 1544
50 1267 657 660
18

11
64
9
60h7

1267
1066
1267
90

1810

1829
900
700
130 28

534
1267
17 22 1297
1317 1323 900
1367 1451 90
RDH K1-1000 430 kg
1660 1541 1544
50 1267 657 660
18
11
64

9
60h7

1267
1066
1267
90

1810

1829
900
700
130 28

534
1267
17 22 1297
1317 1323 900
1367 1451 90
RDH K2-1000 450 kg
1700 1541 1544
50 1267 657 660
18
11
64

9
60h7

1267
1066
1267
90
1810

1829
900

700
130 28
534

1267
17 22 1297
1317 1323 900
1367 1451 90

141
Belt Driven Centrifugal Fans / RDH / Twin fan arrangement

RDH G2E4 / RDH G2K

Dimensions in mm, subject to change.


RDH G2E4-0250/-0560 / RDH G2K-0630/-1000
M H H1
E V E K G G1

S
=

A2
w t

F
C
B

B1
X2
z
dh7
165 28

Q
max.

=
P X3 P = X1 =
L US A R

RDH G2E4-0250/-0355 RDH G2E4-0400/-0560 RDH G2K-0630 RDH G2K-0710/-1000


13 C2 C2 13 13 C2 E2 C2 13 13 C2 E2 C2 13 13 C2 E2 C2 13
= =

9 9 9 9
B2

B2

B2

B2
A2 A2 A2 A2

RDH G2E4-0250/-0560 / RDH G2K-0630/-1000


A B C E F G H L M P
0250 390 474 322 322 268 195 427 943 1085 352
0280 439 530 361 361 302 215 474 1062 1220 391
0315 490 592 403 404 338 236 526 1182 1340 434
0355 551 669 450 453 381 261 588 1341 1505 493
0400 618 754 507 507 432 290 659 1494 1660 547
0450 691 845 571 569 487 322 735 1668 1870 619
0500 760 935 641 638 541 352 809 1856 2060 688
0560 855 1050 716 715 606 390 903 2090 2330 765
0630 940 1157 801 801 679 434 1005 2332 2576 851
0710 1050 1303 898 898 765 485 1121 2606 2898 948
0800 1181 1468 1007 1007 862 540 1255 2914 3257 1057
0900 1319 1648 1130 1130 971 604 1408 3260 3550 1180
1000 1451 1810 1267 1267 1066 657 1541 3634 3927 1317

Q R S V K X1 X2 X3 t w
0250 140 37 10 250 71 224 224 220 8 40
0280 158 35 9 280 79 280 280 250 8 40
0315 177 36 10 315 79 280 280 285 8 40
0355 204 37 13 355 82 355 355 315 10 50
0400 234 41 11 400 83 355 355 360 10 50
0450 261 44 11 450 101 530 530 400 12 70
0500 282 49 10 500 102 530 530 450 12 70
0560 319 48 13 560 120 530 530 510 14 90
0630 349 59 7 630 122 530 530 580 14 90
0710 398 71 7 710 146 630 630 660 18 91
0800 453 74 8 800 172 710 710 750 18 91
0900 510 89 8 900 145 800 800 850 18 91
1000 534 90 9 1000 147 900 900 950 18 91

z d us B1 H1 G1 A2 B2 C2 E2
0250 28 25h7 11 16 490 430 198 322 378 176.0
0280 33 30h7 13 18 547 477 218 361 417 195.5
0315 33 30h7 13 18 608 529 239 404 460 217.0
0355 38 35h7 13 18 682 591 264 453 509 241.5
0400 38 35h7 13 18 769 662 293 507 563 168.5 200
0450 43 40h7 13 18 860 738 325 569 625 199.5 200
0500 43 40h7 13 18 951 812 355 638 694 209.0 250
0560 53.5 50h7 13 18 1063 906 393 715 771 247.5 250
0630 53.5 50h7 13 18 1179 1008 437 801 857 265.5 300
0710 64 60h7 17 22 1391 1124 488 898 954 264.0 400
0800 64 60h7 17 22 1561 1258 543 1007 1063 268.5 500
0900 64 60h7 17 22 1748 1411 607 1130 1186 280.0 600
1000 64 60h7 17 22 1930 1544 660 1267 1323 298.5 700

142
Belt Driven Centrifugal Fans / RDH / Twin fan arrangement

RDH G2E7 / RDH G2K2

Dimensions in mm, subject to change.


RDH G2E7-0250/-0560 / RDH G2K2-0630/-1000
M H H1
E V E K G G1

S
=

A2
w t

F
C
B

B1
X2
z
dh7
165 28

Q
max.

=
P X3 P = X1 =
L US A R

RDH G2E7-0250/-0355 RDH G2E7-0400/-0560 RDH G2K2-0630 RDH G2K2-0710/-1000


13 C2 C2 13 13 C2 E2 C2 13 13 C2 E2 C2 13 13 C2 E2 C2 13
= =

9 9 9 9
B2

B2

B2

B2
A2 A2 A2 A2

RDH G2E7-0250/-0560 / RDH G2K2-0630/-1000


A B C E F G H L M P
0250 390 474 322 322 268 195 427 943 1085 352
0280 439 530 361 361 302 215 474 1062 1230 391
0315 490 592 403 404 338 236 526 1182 1400 434
0355 551 669 450 453 381 261 588 1341 1545 493
0400 618 754 507 507 432 290 659 1494 1800 547
0450 691 845 571 569 487 322 735 1668 1924 619
0500 760 935 641 638 541 352 809 1856 2146 688
0560 855 1050 716 715 606 390 903 2090 2380 765
0630 940 1157 801 801 679 434 1005 2332 2576 851
0710 1050 1303 898 898 765 485 1121 2606 2898 948
0800 1181 1468 1007 1007 862 540 1255 2914 3257 1057
0900 1319 1648 1130 1130 971 604 1408 3260 3550 1180
1000 1451 1810 1267 1267 1066 657 1541 3634 3927 1317

Q R S V K X1 X2 X3 t w
0250 140 37 10 250 71 224 224 220 8 40
0280 158 35 9 280 84 280 280 250 10 50
0315 177 36 10 315 109 280 280 285 12 70
0355 204 37 13 355 102 355 355 315 12 70
0400 234 41 11 400 153 355 355 360 14 90
0450 261 44 11 450 128 530 530 400 14 90
0500 282 49 10 500 145 530 530 450 18 90
0560 319 48 13 560 145 530 530 510 18 90
0630 349 59 7 630 122 530 530 580 18 91
0710 398 71 7 710 146 630 630 660 18 91
0800 453 74 8 800 172 710 710 750 18 91
0900 510 89 8 900 145 800 800 850 18 91
1000 534 90 9 1000 147 900 900 950 18 91

z d us B1 H1 G1 A2 B2 C2 E2
0250 33 30h7 11 16 490 430 198 322 378 176
0280 38 35h7 13 18 547 477 218 361 417 195.5
0315 43 40h7 13 18 608 529 239 404 460 217
0355 43 40h7 13 18 682 591 264 453 509 241.5
0400 53.5 50h7 13 18 769 662 293 507 563 168.5 200
0450 53.5 50h7 13 18 860 738 325 569 625 199.5 200
0500 64 60h7 13 18 951 812 355 638 694 209 250
0560 64 60h7 13 18 1063 906 393 715 771 247.5 250
0630 64 60h7 13 18 1179 1008 437 801 857 265.5 300
0710 64 60h7 17 22 1391 1124 488 898 954 264.0 400
0800 64 60h7 17 22 1561 1258 543 1007 1063 268.5 500
0900 64 60h7 17 22 1748 1411 607 1130 1186 280.0 600
1000 64 60h7 17 22 1930 1544 660 1267 1323 298.5 700

143
Belt Driven Centrifugal Fans / RDH / Specifications

RDH E0-0180/-0560

Specifications
High performance centrifugal fan RDH E0
Double inlet belt drive.
Lap jointed scroll of galvanised sheet steel assembled through a standing-seam.
Multi-position feet and discharge flange as an option.
Centrifugal impeller with 8 backward inclined blades made of fibreglass reinforced
polyamide (sizes 0180/-0225) or with 11 backward inclined blades made of sheet
steel, welded and coated, balanced in according to ISO1940.
Throat plate inclined to blade trasling edge.
Noise tested, maintenance free, self aligning radial insert ball bearings, mounted in
pressed steel housing/strut assemblies with rubber interliners.
Performance data in according to DIN24166 tolerance class 2 (sizes 0180/-0315)
tolerance class 1 (sizes 0355/-0560).

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Multi-Position feet
Discharge flange
Discharge flex with flexible sleeve
Inlet guard
Discharge guard
Shaft guard for free shaft end
Matching flange
Inspection door
Drain plug R 1/8"
Increase corrosion protection
Volumeter
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone

144
Belt Driven Centrifugal Fans / RDH / Specifications

RDH E2-0180/-0560
RDH R-0630/-0710
Specifications
High performance centrifugal fan RDH E2 / RDH R
Double inlet belt drive.
Lap jointed scroll of galvanised sheet steel assembled through a standing-seam (sizes
0160/-0560) or by Pittsburgh lockforming (sizes 0630/-0710), discharge flange as an
option.
Rectangular side frame of galvanised steel.
Centrifugal impeller with 8 backward inclined blades made of fibreglass reinforced
polyamide (sizes 0180/-0225) or with 11 backward inclined blades made of sheet
steel, welded and coated, balanced in according to ISO1940.
Throat plate inclined to blade trasling edge.
Noise tested, maintenance free, self aligning radial insert ball bearings, mounted in
pressed steel housing/strut assemblies with rubber interliners.
Performance data in according to DIN24166 tolerance class 2 (sizes 0180/-0315) or
tolerance class 1 (sizes 0355/-0710).

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Multi-Position feet
Discharge flange
Discharge flex with flexible sleeve
Inlet guard
Discharge guard
Shaft guard for free shaft end
Matching flange
Inspection door
Drain plug R 1/8"
Increase corrosion protection
Volumeter
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone, or equipped with a copper strip (from size 0630)

145
Belt Driven Centrifugal Fans / RDH / Specifications

RDH E4-0200/-0560 RDH G2E4-0250/-0560


RDH K-0630/-1000 RDH G2K-0630/-1000
Specifications
High performance centrifugal fan RDH E4 / RDH K
Double inlet, belt drive.
Lap jointed scroll of galvanised sheet steel assembled through a standing-seam
(Sizes 0200/-0560) or by Pittsburgh lockforming (sizes 0630/-1000), discharge flange
as an option.
Welded heavy duty reinforced side frames, coated.
Centrifugal impeller with 8 backward inclined blades made of fibreglass reinforced po-
lyamide (sizes 0200/-0225) or with 11 backward inclined blades made of sheet steel,
welded and coated (sizes 0250/-1000), balanced in according to ISO1940.
Throat plate inclined to blade trasling edge.
Monobloc pedestal cast iron bearings with relubrication nipple, mounted on a robust
pedestal, integrated, self aligning radial insert ball bearings fixed by eccentric clamp.
Performance data in according to DIN24166 tolerance class 2 (sizes 0200/-0315) or
tolerance class 1 (sizes 0355/-1000).

Twin fan arrangement


Twin fan arrangement
High performance centrifugal fanRDH G2E4/RDH G2K
The two single fans RDH E4 or RDH K are fitted together to a robust assembly by
means of 3 crossbars. Both impellers are fitted on a common shaft supported by 3
bearings.(sizes 0250/-0630) or the fans have separated shafts being connected by a
flexible coupling (sizes 0710/-1000).

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Discharge flange
Discharge flex with flexible sleeve
Inlet guard
Discharge guard
Shaft guard for free shaft end
Matching flange
Inspection door
Drain plug R 1/8"
Reinforcing side frame hot dip galvanised
Increase corrosion protection
Volumeter
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone, or equipped with a copper strip (as from size 0630)

146
Belt Driven Centrifugal Fans / RDH / Specifications

RDH E6-0315/-0560
RDH K1-0630/-0900
Specifications
High performance centrifugal fan RDH E6 / RDH K1
Double inlet, belt drive.
Lap jointed scroll of galvanised sheet steel assembled through a standing-seam or by
Pittsburgh lockforming (sizes 0630/-1000), discharge flange as an option.
Welded heavy duty reinforced side frames, coated.
Centrifugal impeller with 11 backward inclined blades made of sheet steel, welded
and coated, balanced in according to ISO1940.
Throat plate inclined to blade trasling edge.
Monobloc pedestal cast iron bearings with relubrication nipple, mounted on a robust
pedestal, integrated, self aligning radial insert ball bearings fixed by conical sleeve.
Performance data in according to DIN24166 tolerance class 2 (size 0315) or toleran-
ce class 1 (sizes 0355/-1000).

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Discharge flange
Discharge flex with flexible sleeve
Inlet guard
Discharge guard
Shaft guard for free shaft end
Matching flange
Inspection door
Drain plug R 1/8"
Reinforcing side frame hot dip galvanised
Increase corrosion protection
Volumeter
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone, or equipped with a copper strip (from size 0630)

147
Belt Driven Centrifugal Fans / RDH / Specifications

RDH E7-0500/-0560
RDH K2-0630/-1000
Specifications
High performance centrifugal fan RDH E7 / RDH K2
Double inlet belt drive.
Lap jointed scroll of galvanised sheet steel assembled through a standing-seam
(Sizes 0500/-0560) or by Pittsburgh lockforming (sizes 0630/-1000), discharge flange
as an option.
Welded heavy duty reinforced side frames, coated.
Centrifugal impeller with 11 backward inclined blades made of sheet steel, welded
and coated, balanced in according to ISO1940.
Throat plate inclined to blade trasling edge.

Size 0500
Monobloc pedestal cast iron bearings with relubrication nipple, mounted on a robust
pedestal, integrated, self aligning radial insert ball bearings fixed by conical sleeve
Sizes 0560 up to 0800
Split pedestal cast iron bearings with relubrication nipple, mounted on a robust pe-
destal, integrated self aligning double row bearings fixed by conical sleeve, lubricated
with long life high performance grease.
Sizes 0900 and 1000
Single-piece piller blocks with relubrication nipple, mounted on a robust pedestal,
integrated double row, self aligning roller bearings fixed by conical sleeve, lubricated
with long life high performance grease.

Performance data in according to DIN24166 tolerance class 1.

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Discharge flange
Discharge flex with flexible sleeve
Inlet guard
Discharge guard
Shaft guard for free shaft end
Matching flange
Inspection door
Drain plug R 1/8"
Reinforcing side frame hot dip galvanised
Increase corrosion protection
Volumeter
Threaded hole for measurement of shock impulse (sizes 0560 up to 1000)
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone, or equipped with a copper strip (from size 0630)

148
Belt Driven Centrifugal Fans / RDH / Specifications

RDH G2E7-0250/-0560
RDH G2K2-0630/-1000
Specifications
Centrifugal twin fan RDH G2E7 / RDH G2K2
Double inlet belt drive.
Lap jointed scroll of galvanised sheet steel assembled through a standing-seam (sizes
0250/-0560) or by Pittsburgh lockforming (sizes 0630/-1000), fitted together to a
robust assembly by means of 3 crossbars, discharge flange as an option.
Welded heavy duty reinforced side frames, coated.
Both impellers, with 11 backward inclined blades made of sheet steel, welded and
coated, are fitted on a common shaft supported by 3 bearings (sizes 0250/-0630)
or the fans have separated shafts being connected by an elastic coupling (sizes
0710/-1000), balanced in according to ISO1940.
Throat plate inclined to blade trasling edge.

Sizes 0250 up to 0630


Single piece cast iron block housing with relubrication nipple, mounted on a robust
pedestal, integrated, maintenance free, self aligning radial insert ball bearings fixed by
eccentric clamp.
Sizes 0710 up to 1000
Split pedestal cast iron block housing with relubrication nipple, mounted on a robust
pedestal,
outside bearings: integrated self aligning double row roller bearings, fixed by conical
tightening sleeve, lubricated with long life high performance grease.
inside bearings: integrated single row ball bearings, fixed by eccentric clamp, lubrica-
ted with long life high performance grease.

Performance data in according to DIN24166 tolerance class 2 (sizes 0250/-0315) or


to tolerance class 1 (Sizes 0355/-1000).

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Discharge flange
Discharge flex with flexible sleeve
Inlet guard
Discharge guard
Shaft guard for free shaft end
Matching flange
Inspection door
Drain plug R 1/8"
Reinforcing side frame hot dip galvanised
Increase corrosion protection
Volumeter
Threaded hole for measurement of shock impulse (sizes 0560 up to 1000)
Shaft made of stainless steel
Nuts and bolts and fastening elements made of stainless steel
Aluminium inlet cone
Copper inlet cone, or equipped with a copper strip (from size 0630)

149
Highest system performance and best energy efficiency

The RZR series


It is not difficult to make a centrifugal fan for an air conditioning unit a few euros
cheaper.
But to construct it so that it saves valuable energy during operation is a real technolo-
gical challenge.
In this respect, the RZR from NicotraGebhardt continues to provide the technology
with the highest level of system performance and with that, the best solution where
energy efficiency counts.
rotavent the efficient fan technology with centrifugal impeller and airfoil blades.

Top quality for performance and a long service life!


The advantages:
Wide range of application even for high pressures
Easy adaption to changed operating conditions thanks to the belt drive
Easy and reliable layout, performance data complying with tolerance class 1
High degree of performance density at the best efficiency
Low level of noise thanks to the blade profile, a patented blade positioning and the
V-cut off
Easy selection via the proSELECTAII electronic catalogue

We do it very precisely!
Or
Why you should not compare apples with pears!
Nicotra-Gebhardt manufactures its centrifugal fans RZR with tolerance class1 in
compliance with DIN24166.
This gives you the necessary degree of security that you need when designing and
planning ventilation installations. The tolerance class is also an important criterion for
the objective comparison of fans.
If you compare the price/performance ratio of two fans, you should also always take
the tolerance class of each into account, only then do you avoid comparing "apples
with pears"!

Deviations per tolerance class


Performance data
1 2 3

Volume flow qV 2.5 % 5% 10 %

Pressure increase pF 2.5 % 5% 10 %

Power consumption P +3 % +8 % +16 %

Efficiency h -2 % -5 % -

Sound power level (A weighted) LWA +3 dB +4 dB +6 dB

150
Variety has a name

RZR rotavent
RZR fans, double inlet with patented impeller geometry and tapered trailing airfoil blades are the leading edge for standard fans for ventilation and
air conditioning units.

Series RZR Series RZR


Sizes 0200/-1600 Volume up to 300,000 m3/h
Lap jointed scroll of galvanised sheet steel with V-Cut off Pressure up to 3,500 Pa
(RZR 11; 12; 14; 15; 18)
Scroll casing stitch welded and coated, with V-cut off (RZR 13; 19)
Centrifugal impeller with 11 backward inclined steel blades, welded
and coated (0200/-0280)
High pervormance impeller with 12 hollow section true airfoil blades
(0315/-1600)

The right fan for every specification!


Depending on the fan size, the RZR series have up to 7 mechanical versions of the single fan. In this way, we ensure that we have the perfect
model for all requirements and any application.

Version Description Figure

Lap jointed scroll with multi-position feet and discharge flange.


RZR 11-0200/-0710
Light duty bearing execution with pressed steel housing/strut assemblies.

Lap jointed scroll with rectangular side frame and discharge flange.
RZR 12-0200/-0710
Light duty bearing execution with pressed steel housing/strut assemblies.

Lap jointed scroll with heavy duty reinforced side frames and discharge flange.
RZR 15-0400/-1000
Medium-heavy duty bearing execution with cast iron housing/strut assemblies.

Lap jointed scroll with discharge flange and heavy duty reinforced side frames.
RZR 18-0400/-1000
Heavy duty bearing execution with split-type plummer block, mounted on robust pedestal.

Version Description Figure

Scroll casing stitch welded with discharge flange and multi-position feet.
RZR 19-0200/-0355
Medium-heavy bearing execution with cast iron housing and tubular struts.

Scroll casing stitch welded with discharge flange, and heavy duty reinforced side frames, epoxy
RZR 19-0400/-1000 coated.
Medium-heavy bearing execution with cast iron housing and tubular struts.

Scroll casing stitch welded with discharge flange and heavy duty reinforced side frames, epoxy
RZR 13-0400/-1000 coated.
Heavy duty bearing execution with split-type plummer blocks, mounted on robust pedestal.
Heavy duty casing of sheet steel with stiffening members, step welded and painted, with
discharge flange. Casing is split on one axis (Size 1120), split on two axis (Sizes 1250, 1400,
RZR 13-1120/-1600
1600).
Heavy duty bearing execution with split-type plummer blocks, mounted on robust pedestal.

151
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0200

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 204 mm Impeller weight m 2.7 kg RZR 11/12/19 6513 1/min
Number of blades z 11 Density of media r1 1.2 kg/m
Moment of Inertia J 0.020 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area!

%
Pa N all types suitable kW

56

65

70
N do not use in this area 4.0 4.5

72
4000 a (N
ma

70
3.0 x)
3500
2.5
3000
2.0

60
2500
1.5

50
2000

1.0

40
1500 0.8
0.7
0.6

30
0.5
1000
0.4
800
0.3

A
a
P

1/min m/s
600

18
0.2
500 7490 1.0
80

400
102 dB 6600 70
1.0

300 6000
99
1.0

5500 60
72 0.99
96
5000
f pd

200
No

50
rm

93
4500
al

5
1.0
op

0.98
era

150 45
tio

90 4000
na
rea

75 40 0.97
1.1

87 3600
100
35 0.96
84 3200
80
0.95
81 2800 30
1.2

0.94
60
;7
A4

78
LW

2400
5
1.2

25 0.92
A
pF

40
N

500 600 800 1000 1500 2000 3000 4000 5000 6000 8000 m/h
Measured in installation B
0.15 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.5 2.0 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 40 m/s
v2

3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 500 700 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -4 2 0 -2 -5 -10 -14 -21 dB 11 8 3 -2 -8 -13 -19 -29 dB
>0.8-1.2 qVopt -7 0 -2 -2 -5 -9 -14 -22 dB 7 5 1 -1 -7 -11 -18 -29 dB
3745 1/min
>1.2-1.6 qVopt -10 -4 -4 -2 -4 -8 -15 -24 dB 5 3 -1 -1 -6 -9 -17 -20 dB
>1.6 qVopt -12 -7 -6 -2 -4 -8 -13 -24 dB 6 1 -2 -2 -6 -8 -14 -29 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -7 -1 -2 -2 -4 -10 -16 -23 dB 8 7 2 -2 -6 -11 -19 -28 dB
>0.8-1.2 qVopt -12 -4 -5 -3 -4 -10 -15 -23 dB 4 3 -2 -4 -6 -8 -15 -26 dB
>3745 1/min
>1.2-1.6 qVopt -14 -7 -8 -4 -4 -9 -12 -21 dB 2 0 -4 -5 -6 -8 -13 -24 dB
>1.6 qVopt -15 -10 -11 -4 -4 -9 -12 -19 dB 4 0 -4 -6 -6 -8 -12 -21 dB

152
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0200

Dimensions in mm, subject to change.


RZR 11-0200 11 kg
351 358 399
418 22 161 168

358
374
7 6
2 90
286

228
254
306

256
20h6

409
385

89
384

351
190
167
130 25

286 8 22 22
309 160 160
200 200
RZR 12-0200 12 kg
351 358 402
418 161 168

358
377
7 6
2 90
306

254

228
286

256
20h6

402
89
377
388

351

328
190
130 25
160
286 7 74 180 180 104
309 328 388
RZR 19-0200 13 kg
358 399
418 22 168 242
89
7 6
2 90
306

254

256
228

20h6
286

409

358
385

89

190
167

130 25

286 8 22 22
309 160 160
200 200

153
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0225

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 230 mm Impeller weight m 3.5 kg RZR 11/12/19 5774 1/min
Number of blades z 11 Density of media r1 1.2 kg/m
Moment of Inertia J 0.030 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area!
Pa

%
N all types suitable kW

65
57

70
N do not use in this area 5.0 6.0
a (N

73
4000 ma
4.0 x)
3500

70
3000 3.0
2.5

60
2500
2.0
2000 1.5

50
1500 1.0

40
0.8
0.7
1000 0.6

30
0.5
800 0.4

A
a
P

0.3 1/min m/s

19
600 0.25
6640 80 1.0
500 0.2
105 dB
6000
400 70
102 5500
1.0

300 5000 60
99
1.0

72
4500
96 0.99
f pd

200 50
No

4000
rm

5
al

93
1.0

45
op

75
era

150 3600
tio
na

90
1.1

40 0.98
rea

3200
87
100 35
2800 0.97
80 84
1.2

30
2400 0.96
81
60
;7

0.95
A4

78 2100 25
5

LW
1.2
A
pF

40
N

600 800 1000 1500 2000 3000 4000 5000 6000 8000 10000 m/h
Measured in installation B
0.15 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.5 2.0 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 500 700 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -4 2 0 -2 -5 -10 -14 -21 dB 11 8 3 -2 -8 -13 -19 -29 dB
>0.8-1.2 qVopt -7 0 -2 -2 -5 -9 -14 -22 dB 7 5 1 -1 -7 -11 -18 -29 dB
3321 1/min
>1.2-1.6 qVopt -10 -4 -4 -2 -4 -8 -15 -24 dB 5 3 -1 -1 -6 -9 -17 -20 dB
>1.6 qVopt -12 -7 -6 -2 -4 -8 -13 -24 dB 6 1 -2 -2 -6 -8 -14 -29 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -7 -1 -2 -2 -4 -10 -16 -23 dB 8 7 2 -2 -6 -11 -19 -28 dB
>0.8-1.2 qVopt -12 -4 -5 -3 -4 -10 -15 -23 dB 4 3 -2 -4 -6 -8 -15 -26 dB
>3321 1/min
>1.2-1.6 qVopt -14 -7 -8 -4 -4 -9 -12 -21 dB 2 0 -4 -5 -6 -8 -13 -24 dB
>1.6 qVopt -15 -10 -11 -4 -4 -9 -12 -19 dB 4 0 -4 -6 -6 -8 -12 -21 dB

154
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0225

Dimensions in mm, subject to change.


RZR 11-0225 13 kg
394 399 450
448 26 186 191

403
420
10 6
2 100
322

255
286
348

288
20h6

468
100
431

438

398
212
194
130 30

322 10.5 26 26
348 220 220
270 270
RZR 12-0225 15 kg
398 403 452
448 186 191

403
422
10 6
2 100
348

286

255
322

288
20h6

452
100
422
433

398

366
212
130 30
178
322 10 73 220 220 107
350 366 433
RZR 19-0225 16 kg
399 450
448 26 191 274
100
10 6
2 100
348

286

288
255

20h6
322

468
100

403
431

212
194

130 30

322 10.5 26 26
348 220 220
270 270

155
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0250

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 256 mm Impeller weight m 4.8 kg RZR 11/12 4620 1/min
Number of blades z 11 Density of media r1 1.2 kg/m RZR 19 5076 1/min
Moment of Inertia J 0.052 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area!
Pa kW
N all types suitable

%
59

65

70
N RZR 19 only 6.0 7.0
4000 a (N

75
N do not use in this area 5.0 ma
x)
3500
4.0

70
3000
3.0
2500 2.5

60
2.0
2000

50
1.5
1500

40
1.0
0.8
1000 0.7

30
0.6
800 0.5

A
0.4
1/min m/s

20
600 0.3
a
P

500 0.25 5970 80 1.0


0.2 105 dB 5500
400 70
5000
102
300 4500
1.0

60
99
1.0

4000
72 96
200 50
3600
f pd

0.99
No

93 45
rm

5
1.0
al

150 3200
op
era

90 40
tio
na

1.1

75 2800
rea

100 87 0.98
35

80 84 2400
30 0.97
1.2

81 2100
60
;7
A4

78 25 0.96
5

LW
1.2

1800
A
pF

40
N

800 1000 1500 2000 3000 4000 5000 6000 8000 10000 m/h
Measured in installation B
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.5 2.0 3.0 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 10 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 500 700 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -4 2 0 -2 -5 -10 -14 -21 dB 11 8 3 -2 -8 -13 -19 -29 dB
>0.8-1.2 qVopt -7 0 -2 -2 -5 -9 -14 -22 dB 7 5 1 -1 -7 -11 -18 -29 dB
2984 1/min
>1.2-1.6 qVopt -10 -4 -4 -2 -4 -8 -15 -24 dB 5 3 -1 -1 -6 -9 -17 -20 dB
>1.6 Vopt -12 -7 -6 -2 -4 -8 -13 -24 dB 6 1 -2 -2 -6 -8 -14 -29 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -7 -1 -2 -2 -4 -10 -16 -23 dB 8 7 2 -2 -6 -11 -19 -28 dB
>0.8-1.2 qVopt -12 -4 -5 -3 -4 -10 -15 -23 dB 4 3 -2 -4 -6 -8 -15 -26 dB
>2984 1/min
>1.2-1.6 qVopt -14 -7 -8 -4 -4 -9 -12 -21 dB 2 0 -4 -5 -6 -8 -13 -24 dB
>1.6 qVopt -15 -10 -11 -4 -4 -9 -12 -19 dB 4 0 -4 -6 -6 -8 -12 -21 dB

156
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0250

Dimensions in mm, subject to change.


RZR 11-0250 15 kg
430 438 495
484 28 198 206

440
465
10 6
3 100
356

282
320
382

322
20h6

511
110
476

481

433
234
210
130 30

356 10.5 28 28
381 220 220
270 270
RZR 12-0250 17 kg
432 440 497
484 198 206

440
467
10 6
3 100
382

320

282
356

322
20h6

497
110
467
478

432

402
234
130 30
196
356 10 41 320 320 79
383 402 478
RZR 19-0250 17 kg
438 495
484 28 206 301
110
10 6
3 100
382

320

322
282

20h6
356

511

440
110
476

234
210

130 30

356 10.5 28 28
381 220 220
270 270

157
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0280

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 288 mm Impeller weight m 5.7 kg RZR 11/12/19 4582 1/min
Number of blades z 11 Density of media r1 1.2 kg/m
Moment of Inertia J 0.082 kgm Tolerance class (DIN24166) 2

Performance Curves
Please note coloured area!
Pa N all types suitable kW

%
59

65

70
N RZR 19 only 7.0 8.0
4000
N do not use in this area a (N

75
6.0 ma
3500 x)
5.0
3000

70
4.0
2500
3.0

60
2000 2.5
2.0

50
1500 1.5

40
1.0
1000
0.8

30
0.7
800 0.6

A
0.5
1/min m/s

21
600 0.4
a

5300 80 1.0
P

500 0.3
0.25
400 105 dB 70
4500

300 102 4000 60


1.0

1.0

99 3600
72
50
200 96 3200
f pd

45
5
No

1.0

75 0.99
rm

150 93 2800
al
op

40
era

1.1
tio

90
na

2400
rea

100 35
87
0.98
2100
1.2

80
84 30

60 81 1800
0.97
25
;7
1.3

A4

1600
78
LW
A
pF

40
N

800 1000 1500 2000 3000 4000 5000 6000 8000 10000 15000 m/h
Measured in installation B
0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.5 2.0 3.0 4.0 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 500 700 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -4 2 0 -2 -5 -10 -14 -21 dB 11 8 3 -2 -8 -13 -19 -29 dB
>0.8-1.2 qVopt -7 0 -2 -2 -5 -9 -14 -22 dB 7 5 1 -1 -7 -11 -18 -29 dB
2653 1/min
>1.2-1.6 qVopt -10 -4 -4 -2 -4 -8 -15 -24 dB 5 3 -1 -1 -6 -9 -17 -20 dB
>1.6 qVopt -12 -7 -6 -2 -4 -8 -13 -24 dB 6 1 -2 -2 -6 -8 -14 -29 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -7 -1 -2 -2 -4 -10 -16 -23 dB 8 7 2 -2 -6 -11 -19 -28 dB
>0.8-1.2 qVopt -12 -4 -5 -3 -4 -10 -15 -23 dB 4 3 -2 -4 -6 -8 -15 -26 dB
>2653 1/min
>1.2-1.6 qVopt -14 -7 -8 -4 -4 -9 -12 -21 dB 2 0 -4 -5 -6 -8 -13 -24 dB
>1.6 qVopt -15 -10 -11 -4 -4 -9 -12 -19 dB 4 0 -4 -6 -6 -8 -12 -21 dB

158
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0280

Dimensions in mm, subject to change.


RZR 11-0280 20 kg
478 484 550
526 30 220 226

489
520
10 8
3 100
395

315
358
421

361
25h6

570
123
531

540

483
263
236
130 30

395 10.5 30 30
421 220 220
270 270
RZR 12-0280 23 kg
480 486 552
526 220 226

486
522
10 8
3 100
421

358

314
395

361
25h6

552
123
522
532

480

449
260
130 30
218
395 10 65 320 320 107
423 449 532
RZR 19-0280 23 kg
484 550
526 30 226 334
123
10 8
3 100
421

358

361
315

30h9
395

570

489
123
531

263
236

130 30

395 10.5 30 30
421 220 220
270 270

159
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0315

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 323 mm Impeller weight m 7.1 kg RZR 11/12 3793 1/min
Number of blades z 12 Density of media r1 1.2 kg/m RZR 19 4113 1/min
Moment of Inertia J 0.126 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area!
Pa

%
N all types suitable kW

65

70
N RZR 19 only 10

75
8.0
4000

77
N do not use in this area 7.0 a (N
ma
3500

75
6.0 x)

3000 5.0

70
4.0
2500

60
3.0
2000 2.5

50
2.0
1500
1.5

40
1.0
1000
0.8

A 30
800 0.7
0.6
0.5 1/min m/s

22
600
0.4
4730 80 1.0
a

500
P

0.3
105 dB
400 0.25 70
4000
102
300 3600 60
1.0

99
1.0

3200
72 96
50
200
2800
f pd
No

93 45
1.0
rm
al

150
op
era

90 2400 40
1.1
tio

75 0.99
na
rea

87 2100 35
100

84
1.2

80 1800 30
81
60 1600 0.98
;7
A4

25
1.3

78
LW

1400
A
pF

40
N

1000 1500 2000 3000 4000 5000 6000 8000 10000 15000 20000 m/h
Measured in installation B
0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.5 2.0 3.0 4.0 5.0 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 500 700 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt 0 2 0 -3 -6 -9 -12 -19 dB 13 7 4 -3 -8 -14 -17 -25 dB
>0.8-1.2 qVopt -2 1 -2 -3 -6 -8 -14 -20 dB 10 5 3 -2 -7 -13 -17 -25 dB
2365 1/min
>1.2-1.6 qVopt -3 0 -1 -3 -6 -8 -14 -21 dB 7 2 2 -2 -6 -12 -18 -27 dB
>1.6 qVopt -5 -3 -3 -3 -6 -7 -13 -21 dB 5 1 1 -2 -6 -10 -17 -27 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -2 -1 -3 -1 -6 -10 -15 -21 dB 11 4 2 0 -7 -12 -17 -24 dB
>0.8-1.2 qVopt -7 -4 -5 -1 -6 -9 -14 -21 dB 7 1 -2 -3 -6 -10 -15 -23 dB
>2365 1/min
>1.2-1.6 qVopt -10 -7 -8 -1 -5 -8 -13 -21 dB 3 -2 -4 -3 -5 -9 -14 -23 dB
>1.6 qVopt -10 -8 -8 -2 -6 -8 -11 -18 dB 2 -3 -5 -3 -5 -9 -12 -21 dB

160
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0315

Dimensions in mm, subject to change.


RZR 11-0315 24 kg
530 536 613
570 33 241 247

541
583
10 8
3 100
438

355
401
464

404
25h6

624
139
597

594

535
294
253
130 30

438 10.5 33 33
463 220 220
270 270
RZR 12-0315 27 kg
533 539 615
570 241 247

539
585
10 8
3 100
464

401

352
438

404
25h6

615
139
585
596

533

502
292
130 30
244
438 10 86 330 330 133
465 502 596
RZR 19-0315 28 kg
536 613
570 33 247 371
139
10 8
3 100
464

401

404
355

30h9
438

624

541
139
597

294
253

130 30

438 10.5 33 33
463 220 220
270 270

161
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0355 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 363 mm Impeller weight m 9.1 kg RZR 11/12 3110 1/min
Number of blades z 12 Density of media r1 1.2 kg/m RZR 19 3555 1/min
Moment of Inertia J 0.220 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt GmbH
Pa N all types suitable kW certifies that the fan shown

%
66

75
N RZR 19 only 10 herein is licensed to bear the
4000 15

79
a (N
N do not use in this area ma
AMCA Seal.
3500 8.0 x)
7.0 The ratings shown are based

75
3000 6.0 on tests and procedures
performed in accordance

70
5.0
2500 with AMCA Publication 211
4.0 and comply with the require-

60
2000 ments of the AMCA Certified
3.0
Ratings Program.
2.5

50
1500 The AMCA Certified Ratings
2.0 Seal applies to air perfor-
mance ratings only.

40
1.5
1000

A
1.0
800 0.8
0.7

24
0.6 1/min m/s
600 80
0.5 4200 1.0
a

500
P

0.4
70
105 dB 3600
400 0.3

102 3200 60
300
1.0

99 2800
69
1.0

50
200 96
2400 45
f pd

72
5

93
No

1.0
rm

150 40
2100
al
op

1.1

90
era
tio

75
na

35
1800
rea

100 87
1.2

0.99
84 1600 30
80

1400
1.3

81
60
25
;7
A4
5
1.3

78
LW

1200
A
pF

40
N

1500 2000 3000 4000 5000 6000 8000 10000 15000 20000 m/h
Measured in installation B
0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.5 2.0 3.0 4.0 5.0 6.0 7.0 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt 0 2 0 -3 -6 -9 -12 -19 dB 13 7 4 -3 -8 -14 -17 -25 dB
>0.8-1.2 qVopt -2 1 -2 -3 -6 -8 -14 -20 dB 10 5 3 -2 -7 -13 -17 -25 dB
2105 1/min
>1.2-1.6 qVopt -3 0 -1 -3 -6 -8 -14 -21 dB 7 2 2 -2 -6 -12 -18 -27 dB
>1.6 qVopt -5 -3 -3 -3 -6 -7 -13 -21 dB 5 1 1 -2 -6 -10 -17 -27 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -2 -1 -3 -1 -6 -10 -15 -21 dB 11 4 2 0 -7 -12 -17 -24 dB
>0.8-1.2 qVopt -7 -4 -5 -1 -6 -9 -14 -21 dB 7 1 -2 -3 -6 -10 -15 -23 dB
>2105 1/min
>1.2-1.6 qVopt -10 -7 -8 -1 -5 -8 -13 -21 dB 3 -2 -4 -3 -5 -9 -14 -23 dB
>1.6 qVopt -10 -8 -8 -2 -6 -8 -11 -18 dB 2 -3 -5 -3 -5 -9 -12 -21 dB

162
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0355

Dimensions in mm, subject to change.


RZR 11-0355 33 kg
591 598 685
620 36 266 273

602
655
10 8
4 100
487

397
450
513

453
25h6

689
157
668

659

595
329
275
130 30

487 10.5 36 36
513 220 220
270 270
RZR 12-0355 36 kg
593 600 688
620 266 273

600
658
10 8
4 100
513

450

395
487

453
25h6

688
157
658
669

593

562
327
130 30
274
487 10 81 400 400 135
515 562 669
RZR 19-0355 39 kg
598 685
620 36 273 414
157
10 8
4 100
513

450

453
397

30h9
487

689

602
157
668

329
275

130 30

487 10.5 36 36
513 220 220
270 270

163
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0400 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 406 mm Impeller weight m 10.5 kg RZR 11/12 2552 1/min
Number of blades z 12 Density of media r1 1.2 kg/m RZR 18 2913 1/min
Moment of Inertia J 0.33 kgm Tolerance class (DIN24166) 1 RZR 13 3145 1/min

Performance Curves
Please note coloured area! NicotraGebhardt GmbH
Pa N all types suitable

%
certifies that the fan shown

75
66

80
N RZR 13/15/18/19 only kW 15 herein is licensed to bear the

81
a (N
4000 20
N do not use in this area ma AMCA Seal.

80
10 x)
3500 The ratings shown are based
8.0 on tests and procedures
3000
7.0
performed in accordance

70
2500 6.0
with AMCA Publication 211
5.0
and comply with the require-

60
2000 4.0 ments of the AMCA Certified
Ratings Program.

50
3.0
1500 The AMCA Certified Ratings
2.5 Seal applies to air perfor-
2.0 mance ratings only.

40
1000 1.5

A
800 1.0

25
1/min m/s
0.8
3760 80 1.0
600 0.7
0.6 108 dB
a

500
P

0.5 70
3200
105
400 0.4
2800 60
102
300
1.0

99 2400
1.0

50
72
96
f pd

200 2100 45 0.99


5
1.0
No

93
rm

40
150
1.1

75
al

1800
op
era

90
tio

35 0.98
na

1600
1.2
rea

100 87
1400 30
84 0.97
1.3

80
78
;7

81 1200 0.96
A4

60 25
LW
1.4

1100
0.95
A
pF

40
N

2000 3000 4000 5000 6000 8000 10000 15000 20000 30000 m/h
Measured in installation B
0.5 0.6 0.7 0.8 0.9 1.0 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt 0 2 0 -3 -6 -9 -12 -19 dB 13 7 4 -3 -8 -14 -17 -25 dB
>0.8-1.2 qVopt -2 1 -2 -3 -6 -8 -14 -20 dB 10 5 3 -2 -7 -13 -17 -25 dB
1882 1/min
>1.2-1.6 qVopt -3 0 -1 -3 -6 -8 -14 -21 dB 7 2 2 -2 -6 -12 -18 -27 dB
>1.6 qVopt -5 -3 -3 -3 -6 -7 -13 -21 dB 5 1 1 -2 -6 -10 -17 -27 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -2 -1 -3 -1 -6 -10 -15 -21 dB 11 4 2 0 -7 -12 -17 -24 dB
>0.8-1.2 qVopt -7 -4 -5 -1 -6 -9 -14 -21 dB 7 1 -2 -3 -6 -10 -15 -23 dB
>1882 1/min
>1.2-1.6 qVopt -10 -7 -8 -1 -5 -8 -13 -21 dB 3 -2 -4 -3 -5 -9 -14 -23 dB
>1.6 qVopt -10 -8 -8 -2 -6 -8 -11 -18 dB 2 -3 -5 -3 -5 -9 -12 -21 dB

164
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0400

Dimensions in mm, subject to change.


RZR 11-0400 43 kg
662 667 767
760 40 297 302

671
737
10 8
4 100
541

445
504

507
567

30h9

773
179
749

743

665
369
310
130 30

546 14 40 40
596 320 320
385 385
RZR 12-0400 49 kg
664 669 769
760 297 302

669
739
10 8
4 100
504
567

444
541

507
30h9

769
179
739
750

664

632
367
130 30
306
546 12 46 540 540 105
578 632 750
RZR 15-0400 61 kg
662 667 767
760 297 302
671

737
 10 8
 4 100
 541

 507
 504

30h9
 567

773
179
775

743

666

639
369
310

130 30

546  12 70 400 70 400


580 540 540
RZR 19-0400 66 kg
667 767
760 302 461
178
10 8
4 100
541

507
302
504

30h9
567

771
178
775

671

639
369
310

130 30

546 12 70 400 70 400


580 540 540
RZR 18-0400 70 kg RZR 13-0400 75 kg
667 767
852 302 461
178
10 8
4 100
541

507
506

302
567

30h9
178
775

639
771

671
369
310

130 30

546 12 70 400 70 400


580 540 540

165
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0450 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 455 mm Impeller weight m 15.8 kg RZR 11/12 2111 1/min
Number of blades z 12 Density of media r1 1.2 kg/m RZR 18 2410 1/min
Moment of Inertia J 0.6 kgm Tolerance class (DIN24166) 1 RZR 13 2922 1/min

Performance Curves
Please note coloured area! NicotraGebhardt GmbH
Pa

%
N all types suitable kW certifies that the fan shown

75
66

80
N RZR 13/15/18/19 only 20 herein is licensed to bear the

81
4000 15 25 a (N
N do not use in this area AMCA Seal.

80
ma
x)
3500 The ratings shown are based
3000 10 on tests and procedures
performed in accordance

70
8.0
2500 7.0 with AMCA Publication 211
6.0 and comply with the require-

60
2000 5.0 ments of the AMCA Certified
4.0 Ratings Program.

50
1500 The AMCA Certified Ratings
3.0 Seal applies to air perfor-
mance ratings only.

40
2.5

A
2.0
1000
1.5
800

25
1/min m/s
1.0 3360 80 1.0
600
0.8 108 dB
a
P

500 0.7
0.6 70
105 2800
400 0.5

102 60
2400
300
1.0

99
1.0

72 2100 50
96
f pd

200 45
5
1.0

1800
75 93
No

40
1.1

0.99
rm

150
al

1600
op

90
era

35
tio

1.2
na

1400
rea

100 87

78 30 0.98
1.3

80 84 1200
;7
A4

81
LW

60 25 0.97
1.4

1000
A
pF

40
N

3000 4000 5000 6000 8000 10000 15000 20000 30000 40000 m/h
Measured in installation B
0.6 0.7 0.8 0.9 1.0 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt 0 2 0 -3 -6 -9 -12 -19 dB 13 7 4 -3 -8 -14 -17 -25 dB
>0.8-1.2 qVopt -2 1 -2 -3 -6 -8 -14 -20 dB 10 5 3 -2 -7 -13 -17 -25 dB
1679 1/min
>1.2-1.6 qVopt -3 0 -1 -3 -6 -8 -14 -21 dB 7 2 2 -2 -6 -12 -18 -27 dB
>1.6 qVopt -5 -3 -3 -3 -6 -7 -13 -21 dB 5 1 1 -2 -6 -10 -17 -27 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -2 -1 -3 -1 -6 -10 -15 -21 dB 11 4 2 0 -7 -12 -17 -24 dB
>0.8-1.2 qVopt -7 -4 -5 -1 -6 -9 -14 -21 dB 7 1 -2 -3 -6 -10 -15 -23 dB
>1679 1/min
>1.2-1.6 qVopt -10 -7 -8 -1 -5 -8 -13 -21 dB 3 -2 -4 -3 -5 -9 -14 -23 dB
>1.6 qVopt -10 -8 -8 -2 -6 -8 -11 -18 dB 2 -3 -5 -3 -5 -9 -12 -21 dB

166
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0450

Dimensions in mm, subject to change.


RZR 11-0450 54 kg
742 750 863
820 44 334 342

755
828
12 8
4 112
605

499
566
640

569
30h9

868
202
840

833

747
413
346
130 35

612 14 44 44
660 320 320
385 385
RZR 12-0450 60 kg
745 753 856
820 334 342

753
821
12 8
4 112
640

566

498
605

569
30h9

856
202
821
841

745

708
411
130 35
343
612 12 54 600 600 121
642 708 841
RZR 15-0450 73 kg
742 750 863
820 334 342
755

828
 12 8
 4 112
 605

 569
 640

 566

30h9
868
202
868

833

747

713
413
346

130 35

612  12 76 448 76 448


644 600 600
RZR 19-0450 82 kg
750 863
820 342 522
202
12 8
4 112
605

569
342
639

566

30h9
868
202
868

755

713
413
346

130 35

612 12 76 448 76 448


644 600 600
RZR 18-0450 83 kg RZR 13-0450 92 kg
750 863
912 342 522
202
12 8
4 112
605

569
570

342
640

30h9
200
868

713
868

755
413
346

130 35

612 12 76 448 76 448


644 600 600

167
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0500 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 510 mm Impeller weight m 19.9 kg RZR 11/12 1752 1/min
Number of blades z 12 Density of media r1 1.2 kg/m RZR 18 2000 1/min
Moment of Inertia J 0.9 kgm Tolerance class (DIN24166) 1 RZR 13 2534 1/min

Performance Curves
Please note coloured area! NicotraGebhardt GmbH
Pa

%
N all types suitable kW certifies that the fan shown

75
68

80
25 30
N RZR 13/15/18/19 only 20 a (N herein is licensed to bear the

82
4000 ma
x)
N do not use in this area AMCA Seal.

80
3500 15 The ratings shown are based
3000 on tests and procedures

70
10 performed in accordance
2500 with AMCA Publication 211
8.0
7.0 and comply with the require-

60
2000 6.0 ments of the AMCA Certified
5.0 Ratings Program.

50
1500 The AMCA Certified Ratings
4.0
Seal applies to air perfor-
3.0 mance ratings only.

40
A
2.5
1000
2.0
800
1.5

25
1/min m/s
600 3000 80 1.0
1.0
a

108 dB
P

500 0.8 2700


0.7 70
105
400 2400
102 60
300 2100
1.0

1.0

72 99
50
1800
f pd

96
5

200
1.0

45
No
rm

75 1600
1.1
al

93
op

150 40
era
tio

1400
na

90
1.2
rea

35 0.99
100 87 1200
1.3

30
80 78 84
;7

1000
A4

81 0.98
LW

60 25
1.4

900
A
pF

40
N

3000 4000 5000 6000 8000 10000 15000 20000 30000 40000 50000 m/h
Measured in installation B
0.8 0.9 1.0 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10 15 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt 0 2 0 -3 -6 -9 -12 -19 dB 13 7 4 -3 -8 -14 -17 -25 dB
>0.8-1.2 qVopt -2 1 -2 -3 -6 -8 -14 -20 dB 10 5 3 -2 -7 -13 -17 -25 dB
1498 1/min
>1.2-1.6 qVopt -3 0 -1 -3 -6 -8 -14 -21 dB 7 2 2 -2 -6 -12 -18 -27 dB
>1.6 qVopt -5 -3 -3 -3 -6 -7 -13 -21 dB 5 1 1 -2 -6 -10 -17 -27 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -2 -1 -3 -1 -6 -10 -15 -21 dB 11 4 2 0 -7 -12 -17 -24 dB
>0.8-1.2 qVopt -7 -4 -5 -1 -6 -9 -14 -21 dB 7 1 -2 -3 -6 -10 -15 -23 dB
>1498 1/min
>1.2-1.6 qVopt -10 -7 -8 -1 -5 -8 -13 -21 dB 3 -2 -4 -3 -5 -9 -14 -23 dB
>1.6 qVopt -10 -8 -8 -2 -6 -8 -11 -18 dB 2 -3 -5 -3 -5 -9 -12 -21 dB

168
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0500

Dimensions in mm, subject to change.


RZR 11-0500 65 kg
813 821 950
890 52 362 370

827
916
12 8
5 112
674

553
635
708

638
30h9

955
221
929

920

819
457
381
130 35

680 14 52 52
729 320 320
385 385
RZR 12-0500 72 kg
817 825 955
890 362 370

825
920
12 8
5 112
708

635

551
674

638
30h9

955
220
920
931

817

780
455
130 35
380
680 12 65 650 650 140
711 780 931
RZR 15-0500 94 kg
813 821 950
890 362 370
827

915
 12 8
 5 112
 674

 638
 708

 635

30h9
955
220
957

920

819

783
457
381

130 35

680  12 46 560 46 560


713 652 652
RZR 19-0500 105 kg
821 950
890 370 574
220
12 8
5 112
674

638
370
708

635

30h9
955
220
957

827

783
457
381

130 35

680 12 46 560 46 560


713 652 652
RZR 18-0500 105 kg RZR 13-0500 116 kg
821 950
986 370 574
220
12 8
5 112
674

638
635

370
708

30h9
220
957

783
955

827
457
381

130 35

680 12 46 560 46 560


713 652 652

169
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0560 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 570 mm Impeller weight m 30 kg RZR 11/12/18 1660 1/min
Number of blades z 12 Density of media r1 1.2 kg/m RZR 13 2163 1/min
Moment of Inertia J 1.7 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt GmbH
Pa N all types suitable certifies that the fan shown

%
kW

75

80
68
N RZR 13/15/18/19 only 25 30 35 a (N herein is licensed to bear the

82
ma
4000 x)
N RZR 13/18 only AMCA Seal.

80
20
3500 N do not use in this area The ratings shown are based
3000 15 on tests and procedures
performed in accordance

70
2500 with AMCA Publication 211
10
and comply with the require-

60
2000 8.0 ments of the AMCA Certified
7.0
6.0
Ratings Program.

50
1500 The AMCA Certified Ratings
5.0
Seal applies to air perfor-
4.0 mance ratings only.

40
A
3.0
1000
2.5
800 2.0
1/min m/s

25
1.5
600 2680 80 1.0
a
P

500 1.0 108 dB 2400


70
0.8
400 105
2100
60
300 102
1.0

1800
1.0

72
99 50
1600
f pd

200
5

75 96 45
1.0
No

1400
rm

1.1
al

150 93 40
op

0.99
era
tio
na

90 1200
1.2

35
rea

78
100
87
1.3

1000 30 0.98
80
84
900
;7
A4
1.4

60 81 25 0.97
LW
A

800
pF

40
N

4000 5000 6000 8000 10000 15000 20000 30000 40000 50000 60000 m/h
Measured in installation B
1.0 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10 15 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt 0 2 0 -3 -6 -9 -12 -19 dB 13 7 4 -3 -8 -14 -17 -25 dB
>0.8-1.2 qVopt -2 1 -2 -3 -6 -8 -14 -20 dB 10 5 3 -2 -7 -13 -17 -25 dB
1340 1/min
>1.2-1.6 qVopt -3 0 -1 -3 -6 -8 -14 -21 dB 7 2 2 -2 -6 -12 -18 -27 dB
>1.6 qVopt -5 -3 -3 -3 -6 -7 -13 -21 dB 5 1 1 -2 -6 -10 -17 -27 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -2 -1 -3 -1 -6 -10 -15 -21 dB 11 4 2 0 -7 -12 -17 -24 dB
>0.8-1.2 qVopt -7 -4 -5 -1 -6 -9 -14 -21 dB 7 1 -2 -3 -6 -10 -15 -23 dB
>1340 1/min
>1.2-1.6 qVopt -10 -7 -8 -1 -5 -8 -13 -21 dB 3 -2 -4 -3 -5 -9 -14 -23 dB
>1.6 qVopt -10 -8 -8 -2 -6 -8 -11 -18 dB 2 -3 -5 -3 -5 -9 -12 -21 dB

170
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0560

Dimensions in mm, subject to change.


RZR 11-0560 103 kg
906 914 1061
1026 59 401 409

921
1030
12 12
6 112
751

620
712
785

715
40h9

1071
1041

247
1036

913
512
431
130 35

756 14 59 59
805 2250 2250
600 600
RZR 12-0560 109 kg
912 920 1067
1026 401 409

920
1032
12 12
6 112
785

712

619
751

715
40h9

1067
247
1032
1046

912

875
511
130 35
427
756 12 63 2 375 2 375 148
787 875 1046
RZR 15-0560 125 kg
906 914 1061
1026 401 409
921

1026
 12 12
 6 112
 751

 715
 785

 712

40h9
1071
1083

247
1036

913

884
512
431

130 35

756  12 92 2 280 92 2 280


789 743 743
RZR 19-0560 136 kg
914 1061
1026 409 640
247
12 12
6 112
751

715
409
785

712

40h9
1071
1083

247

921

884
512
431

130 35

756 12 92 2 280 92 2 280


789 743 743
RZR 18-0560 140 kg RZR 13-0560 151 kg
914 1061
1138 409 640
247
12 12
6 112
751

715
712

409
785

40h9
1083

247
1071

884
921
512
431

130 35

756 12 92 2 280 92 2 280


789 743 743

171
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0630 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 640 mm Impeller weight m 38 kg RZR 11/12/18 1367 1/min
Number of blades z 12 Density of media r1 1.2 kg/m RZR 13 2055 1/min
Moment of Inertia J 2.4 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt GmbH
Pa kW
N all types suitable certifies that the fan shown

75

80
69
N RZR 13/15/18/19 only 40 45 herein is licensed to bear the
30 35

82
a (N
4000
N RZR 13/18 only 25
ma
x) AMCA Seal.

80
3500 N do not use in this area The ratings shown are based
20 on tests and procedures
3000
performed in accordance

70
15
2500 with AMCA Publication 211
and comply with the require-

60
2000 10 ments of the AMCA Certified
8.0 Ratings Program.
7.0

50
1500 The AMCA Certified Ratings
6.0 Seal applies to air perfor-
5.0 mance ratings only.

40
4.0
1000

A
3.0
800 2.5

25
2.0 1/min m/s
600 2380 80 1.0
1.5
a

500
P

108 dB 2100 70
1.0
400
105
1800 60
300 102
1.0

1600
1.0

72 50
99
f pd

1400
200
5

45
1.0

96
75
No

1.1
rm

150 1200 40
al

93 0.99
op
era
tio
na

1.2

78 90 35
rea

1000
100
87 900 30 0.98
1.3

80
84 800
;7
A4

60 25 0.97
LW

81
700
1.4
A
pF

40
N

4000 5000 6000 8000 10000 15000 20000 30000 40000 60000 80000 m/h
Measured in installation B
1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10 15 20 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt 0 2 0 -3 -6 -9 -12 -19 dB 13 7 4 -3 -8 -14 -17 -25 dB
>0.8-1.2 qVopt -2 1 -2 -3 -6 -8 -14 -20 dB 10 5 3 -2 -7 -13 -17 -25 dB
1194 1/min
>1.2-1.6 qVopt -3 0 -1 -3 -6 -8 -14 -21 dB 7 2 2 -2 -6 -12 -18 -27 dB
>1.6 qVopt -5 -3 -3 -3 -6 -7 -13 -21 dB 5 1 1 -2 -6 -10 -17 -27 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -2 -1 -3 -1 -6 -10 -15 -21 dB 11 4 2 0 -7 -12 -17 -24 dB
>0.8-1.2 qVopt -7 -4 -5 -1 -6 -9 -14 -21 dB 7 1 -2 -3 -6 -10 -15 -23 dB
>1194 1/min
>1.2-1.6 qVopt -10 -7 -8 -1 -5 -8 -13 -21 dB 3 -2 -4 -3 -5 -9 -14 -23 dB
>1.6 qVopt -10 -8 -8 -2 -6 -8 -11 -18 dB 2 -3 -5 -3 -5 -9 -12 -21 dB

172
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0630

Dimensions in mm, subject to change.


RZR 11-0630 124 kg
1011 1021 1188
1116 67 444 454

1028
1153
12 12
6 112
837

695
798
871

801
40h9

1195
1168

280
1160

1018
574
479
130 35

843 14 67 67
892 2250 2250
600 600
RZR 12-0630 132 kg
1017 1027 1195
1116 444 454

1027
1160
12 12
6 112
871

798

694
837

801
40h9

1195
280
1160
1173

1017

979
573
130 35
479
845 12 65 2 425 2 425 162
874 979 1173
RZR 15-0630 149 kg
1011 1021 1188
1116 444 454
1028

1153
 12 12
 6 112
 837

 801
 871

 798

40h9
1145
1204

279
1160

1018

984
574
479

130 35

845  12 74 2 336 74 2 336


876 820 820
RZR 19-0630 162 kg
1021 1188
1116 454 715
279
12 12
6 112
837

801
454
871

798

40h9
1195
1204

279

1028

984
574
479

130 35

845 12 74 2 336 74 2 336


876 820 820
RZR 18-0630 167 kg RZR 13-0630 180 kg
1021 1188
1226 454 715
279
12 12
6 112
837

801
798

454
871

40h9
1204

279
1195

1028

984
574
479

130 35

845 12 74 2 336 74 2 336


876 820 820

173
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0710 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 718 mm Impeller weight m 52 kg RZR 11/12/18 1128 1/min
Number of blades z 12 Density of media r1 1.2 kg/m RZR 13 1825 1/min
Moment of Inertia J 4.8 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt GmbH
Pa kW
N all types suitable certifies that the fan shown

%
45 50 60

75

80
69
N RZR 13/15/18/19 only 40 herein is licensed to bear the

83
4000 a (N
N RZR 13/18 only 35 ma AMCA Seal.
30 x)
3500 N do not use in this area The ratings shown are based

80
25 on tests and procedures
3000
20 performed in accordance

70
2500 with AMCA Publication 211
15 and comply with the require-
2000

60
ments of the AMCA Certified
10 Ratings Program.
The AMCA Certified Ratings

50
1500 8.0
7.0 Seal applies to air perfor-
6.0 mance ratings only.

40
5.0
1000

A
4.0
800
3.0
2.5 1/min m/s

25
600 2.0 2120 80 1.0

500 1.5
a
P

70
108 dB 1800
400
1.0
105 1600 60
300
102 1400
1.0

1.0

50
72
99
f pd

200 1200 45
5
1.0

96
No

75
rm

1.1

150 40
al
op

93 1000 0.99
era
tio

35
na

1.2

900
rea

78 90
100
800 30
80 87
1.3

0.98
700
;7

84
A4

60 25
LW

81 0.97
600
1.4
A
pF

40
N

5000 6000 8000 10000 15000 20000 30000 40000 60000 80000 m/h
Measured in installation B
1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10 15 20 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt 0 2 0 -3 -6 -9 -12 -19 dB 13 7 4 -3 -8 -14 -17 -25 dB
>0.8-1.2 qVopt -2 1 -2 -3 -6 -8 -14 -20 dB 10 5 3 -2 -7 -13 -17 -25 dB
1064 1/min
>1.2-1.6 qVopt -3 0 -1 -3 -6 -8 -14 -21 dB 7 2 2 -2 -6 -12 -18 -27 dB
>1.6 qVopt -5 -3 -3 -3 -6 -7 -13 -21 dB 5 1 1 -2 -6 -10 -17 -27 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -2 -1 -3 -1 -6 -10 -15 -21 dB 11 4 2 0 -7 -12 -17 -24 dB
>0.8-1.2 qVopt -7 -4 -5 -1 -6 -9 -14 -21 dB 7 1 -2 -3 -6 -10 -15 -23 dB
>1064 1/min
>1.2-1.6 qVopt -10 -7 -8 -1 -5 -8 -13 -21 dB 3 -2 -4 -3 -5 -9 -14 -23 dB
>1.6 qVopt -10 -8 -8 -2 -6 -8 -11 -18 dB 2 -3 -5 -3 -5 -9 -12 -21 dB

174
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0710

Dimensions in mm, subject to change.


RZR 11-0710 177 kg
1133 1143 1333
1280 73 495 505

1152
1298
12 14
7 112
934

784
894
968

898
50h9

1341
1316

317
1306

1142
647
540
130 35

940 14 73 73
989 2250 2250
600 600
RZR 12-0710 194 kg
1142 1152 1341
1280 495 505

1152
1306
12 14
7 112
968

894

784
934

898
50h9

1341
317
1306
1324

1142

1104
647
130 35
540
940 12 72 2 480 2 480 182
971 1104 1324
RZR 15-0710 201 kg
1133 1143 1333
1280 495 505
1152

1298
 12 14
 7 112
 934

 898
 968

 894

50h9
1341
1350

317
1306

1142

1100
647
540

130 35

940  12 61 2 392 61 2 392


973 905 905
RZR 19-0710 225 kg
1143 1333
1280 505 801
317
 12 14
 7 112
 934

 898
505
 968

 894

50h9
1341
1350

317

1152

1100
647
540

130 35

940  12 61 2 392 61 2 392


973 905 905
RZR 18-0710 230 kg RZR 13-0710 254 kg
1143 1333
1404 505 801
317
12 14
7 112
934

898
894

505
968

50h9
1350

317

1100
1341

1152
647
540

130 35

940 12 61 2 392 61 2 392


973 905 905

175
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0800 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 808 mm Impeller weight m 69 kg RZR 11/18 927 1/min
Number of blades z 12 Density of media r1 1.2 kg/m RZR 13 1474 1/min
Moment of Inertia J 6.85 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt GmbH
Pa kW
N all types suitable certifies that the fan shown

80
75
69
N RZR 13/15/18/19 only 50 60 70 herein is licensed to bear the

84
4000 45 a (N
N RZR 13/18 only 40 ma
x) AMCA Seal.
3500 N do not use in this area 35

80
The ratings shown are based
30 on tests and procedures
3000
25 performed in accordance

70
2500 20 with AMCA Publication 211
and comply with the require-

60
2000 15 ments of the AMCA Certified
Ratings Program.

50
1500 10 The AMCA Certified Ratings
Seal applies to air perfor-
8.0
mance ratings only.

40
7.0
6.0

A
1000 5.0

800 4.0
1/min m/s

25
3.0
600 2.5 1890 80 1.0
2.0
a
P

500
70
1.5 1600
400 108 dB

105 1400 60
300
1.0

102
1.0

1200 50
f pd

200 75 99
5

45
1.0
No

1000
1.1
rm

78 96
al

150 40
op

900
era
tio

93
na

35
1.2
rea

800
100 90
30 0.995
80 700
1.3

87
;7
A4

60 84 600 25
LW

81
550
1.4

0.99
A
pF

40
N

8000 10000 15000 20000 30000 40000 60000 80000 100000 m/h
Measured in installation B
2 3 4 5 6 7 8 9 10 15 20 30 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt 0 2 0 -3 -6 -9 -12 -19 dB 13 7 4 -3 -8 -14 -17 -25 dB
>0.8-1.2 qVopt -2 1 -2 -3 -6 -8 -14 -20 dB 10 5 3 -2 -7 -13 -17 -25 dB
945 1/min
>1.2-1.6 qVopt -3 0 -1 -3 -6 -8 -14 -21 dB 7 2 2 -2 -6 -12 -18 -27 dB
>1.6 qVopt -5 -3 -3 -3 -6 -7 -13 -21 dB 5 1 1 -2 -6 -10 -17 -27 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -2 -1 -3 -1 -6 -10 -15 -21 dB 11 4 2 0 -7 -12 -17 -24 dB
>0.8-1.2 qVopt -7 -4 -5 -1 -6 -9 -14 -21 dB 7 1 -2 -3 -6 -10 -15 -23 dB
>945 1/min
>1.2-1.6 qVopt -10 -7 -8 -1 -5 -8 -13 -21 dB 3 -2 -4 -3 -5 -9 -14 -23 dB
>1.6 qVopt -10 -8 -8 -2 -6 -8 -11 -18 dB 2 -3 -5 -3 -5 -9 -12 -21 dB

176
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0800

Dimensions in mm, subject to change.


RZR 11-0800 250 kg
1270 1280 1499
1390 533 563

1290
1464
12 14
8 112
1043

1007
1087

1003

50h9

1510
1520

359
1475

1280

1245
727
607
130 35

1050 12 70 2 448 70 2 448


1092 1035 1035
RZR 15-0800 250 kg
1270 1280 1499
1390 553 563

1290
1464
12 14
8 112
1043

1007
1087

1003

50h9

1510
1520

359
1475

1280

1245
727
607
130 35

1050 12 70 2 448 70 2 448


1092 1035 1035
RZR 19-0800 280 kg
1280 1499
1390 563 903
359
12 14
8 112
1043

1007
1087

1003

563

50h9
1510
1520

359

1290

1245
727
607

130 35

1050 12 70 2 448 70 2 448


1092 1035 1035
RZR 18-0800 289 kg
1270 1280 1499
1512 553 563
1290

1464
 12 14
 8 112
 1043

 1007
 1006
 1087

50h9
1510
1520

359
1475

1280

1245
727
607

130 35

1050  12 70 2 448 70 2 448


1092 1035 1035
RZR 13-0800 319 kg
1280 1499
1512 563 903
359
12 14
8 112
1043

1007
1003
1087

563

50h9
1520

359

1245
1510

1290
727
607

130 35

1050 12 70 2 448 70 2 448


1092 1035 1035

177
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0900 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 905 mm Impeller weight m 109 kg RZR 11/18 767 1/min
Number of blades z 12 Density of media r1 1.2 kg/m RZR 13 1339 1/min
Moment of Inertia J 15.5 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt GmbH
Pa kW
N all types suitable certifies that the fan shown

80
80

75
69
N RZR 13/15/18/19 only 70 herein is licensed to bear the
60 100

84
4000 a (N
N RZR 13/18 only 50 ma AMCA Seal.
x)
3500 N do not use in this area 45 The ratings shown are based

80
40
3000 on tests and procedures
35
30 performed in accordance

70
2500 with AMCA Publication 211
25
and comply with the require-

60
2000 20 ments of the AMCA Certified
15
Ratings Program.

50
1500 The AMCA Certified Ratings
Seal applies to air perfor-
10 mance ratings only.

40
8.0
1000 7.0

A
6.0
800 5.0
4.0 1/min m/s

25
600 1690 80 1.0
3.0
a
P

500 2.5
111 dB
70
2.0
400 1400
108
60
300 105 1200
1.0

1.0

75 102 50
f pd

1000
5

200
1.0

99 45
78 900
1.1
No

150 96 40
rm
al

800
op
era

1.2
tio

93 35
na

81
700
rea

100
90
30 0.995
1.3

80
600
87
;7
A4

60 25
LW

84
550
1.4
A
pF

40
N

8000 10000 15000 20000 30000 40000 60000 80000 100000 150000 m/h
Measured in installation B
3 4 5 6 7 8 9 10 15 20 30 40 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt 0 2 0 -3 -6 -9 -12 -19 dB 13 7 4 -3 -8 -14 -17 -25 dB
>0.8-1.2 qVopt -2 1 -2 -3 -6 -8 -14 -20 dB 10 5 3 -2 -7 -13 -17 -25 dB
844 1/min
>1.2-1.6 qVopt -3 0 -1 -3 -6 -8 -14 -21 dB 7 2 2 -2 -6 -12 -18 -27 dB
>1.6 Vopt -5 -3 -3 -3 -6 -7 -13 -21 dB 5 1 1 -2 -6 -10 -17 -27 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -2 -1 -3 -1 -6 -10 -15 -21 dB 11 4 2 0 -7 -12 -17 -24 dB
>0.8-1.2 qVopt -7 -4 -5 -1 -6 -9 -14 -21 dB 7 1 -2 -3 -6 -10 -15 -23 dB
>844 1/min
>1.2-1.6 qVopt -10 -7 -8 -1 -5 -8 -13 -21 dB 3 -2 -4 -3 -5 -9 -14 -23 dB
>1.6 qVopt -10 -8 -8 -2 -6 -8 -11 -18 dB 2 -3 -5 -3 -5 -9 -12 -21 dB

178
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-0900

Dimensions in mm, subject to change.


RZR 11-0900 358 kg
1422 1432 1687
1538 618 628

1448
1647
12 18
8 125
1174

1130
1220

1126

50h9

1697
1707

406
1657

1438

1386
816
681
130 40

1178 12 70 2 500 70 2 500


1225 1140 1140
RZR 15-0900 358 kg
1430 1432 1687
1538 618 628

1448
1647
12 18
8 125
1174

1130
1220

1126

60h9

1697
1707

406
1657

1438

1386
816
681
130 40

1178 12 70 2 500 70 2 500


1225 1140 1140
RZR 19-0900 396 kg
1439 1687
1538 632 1016
406
12 18
8 125
1174

1130
1220

1126

632

60h9
1697
1707

406

1448

1386
816
681

130 40

1178 12 70 2 500 70 2 500


1225 1140 1140
RZR 18-0900 409 kg
1422 1432 1687
1658 622 632
1448

1647
 12 18
 8 125
 1174

 1130
 1129
 1220

60h9
1697
1707

406
1657

1438

1386
816
681

130 40

1178  12 70 2 500 70 2 500


1225 1140 1140
RZR 13-0900 447 kg
1439 1687
1658 632 1016
406
 12 18
 8 125
 1174

 1130
 1126
 1220

632

60h9
1707

406

1386
1697

1448
816
681

130 40

1178  12 70 2 500 70 2 500


1225 1140 1140

179
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-1000 Performance certified is for installation type B - free inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 1000 mm Impeller weight m 133 kg RZR 11/18 650 1/min
Number of blades z 12 Density of media r1 1.2 kg/m RZR 13 1217 1/min
Moment of Inertia J 22 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area! NicotraGebhardt GmbH
Pa kW
N all types suitable certifies that the fan shown

%
100

80
75
69
80
N RZR 13/15/18/19 only herein is licensed to bear the

84
a (N
4000 70
N RZR 13/18 only 60
ma
x) AMCA Seal.
3500 N do not use in this area

80
50 The ratings shown are based
3000 45 on tests and procedures
40 performed in accordance

70
2500 35
30
with AMCA Publication 211
and comply with the require-

60
2000 25
ments of the AMCA Certified
20 Ratings Program.

50
1500 The AMCA Certified Ratings
15
Seal applies to air perfor-
mance ratings only.

40
10
1000 8.0

A
7.0
800 6.0
5.0 1/min m/s

25
600 4.0 1530 80 1.0
a
P

500 3.0 1400


2.5 111 dB 70
400
108 1200
60
300
105
1.0

1.0

75 1000
50
102
f pd

900
5

200 78
1.0

45
99
No

800
1.1
rm
al

150 40
op

96
era
tio

81 700
na

1.2

35
rea

93
100
600
90 30
1.3

80
87
;7

500
A4

60 25 0.995
LW

84 450
1.4
A
pF

40
N

10000 15000 20000 30000 40000 60000 80000 100000 150000 m/h
Measured in installation B
3 4 5 6 7 8 9 10 15 20 30 40 5.0 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 m/s
v2

2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt 0 2 0 -3 -6 -9 -12 -19 dB 13 7 4 -3 -8 -14 -17 -25 dB
>0.8-1.2 qVopt -2 1 -2 -3 -6 -8 -14 -20 dB 10 5 3 -2 -7 -13 -17 -25 dB
764 1/min
>1.2-1.6 qVopt -3 0 -1 -3 -6 -8 -14 -21 dB 7 2 2 -2 -6 -12 -18 -27 dB
>1.6 qVopt -5 -3 -3 -3 -6 -7 -13 -21 dB 5 1 1 -2 -6 -10 -17 -27 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -2 -1 -3 -1 -6 -10 -15 -21 dB 11 4 2 0 -7 -12 -17 -24 dB
>0.8-1.2 qVopt -7 -4 -5 -1 -6 -9 -14 -21 dB 7 1 -2 -3 -6 -10 -15 -23 dB
>764 1/min
>1.2-1.6 qVopt -10 -7 -8 -1 -5 -8 -13 -21 dB 3 -2 -4 -3 -5 -9 -14 -23 dB
>1.6 qVopt -10 -8 -8 -2 -6 -8 -11 -18 dB 2 -3 -5 -3 -5 -9 -12 -21 dB

180
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-1000

Dimensions in mm, subject to change.


RZR 11-1000 416 kg
1550 1560 1849
1678 669 679

1573
1809
12 18
9 125
1311

1267
1357

1263

50h9

1859
1869

434
1819

1563

1509
894
746
130 40

1315 12 52 2 563 52 2 563


1362 1230 1230
RZR 15-1000 416 kg
1550 1560 1849
1678 669 679

1573
1809
12 18
9 125
1311

1267
1357

1263

60h9

1859
1869

434
1819

1563

1509
894
746
130 40

1315 12 52 2 563 52 2 563


1362 1230 1230
RZR 19-1000 462 kg
1568 1849
1678 683 1113
434
12 18
9 125
1311

1267
1357

1263

683

60h9
1859
1869

434

1577

1509
894
746

130 40

1315 12 52 2 563 52 2 563


1362 1230 1230
RZR 18-1000 471 kg
1550 1560 1849
1794 569 679
1573

1809
 12 18
 9 125
 1311

 1267
 1266
 1357

60h9
1859
1869

434
1819

1563

1509
894
746

130 40

1315  12 52 2 563 52 2 563


1362 1230 1230
RZR 13-1000 517 kg
1568 1849
1794 683 1113
434
12 18
9 125
1311

1267
1263
1357

683

60h9
1869

434

1509
1859

1577
894
746

130 40

1315 12 52 2 563 52 2 563


1362 1230 1230

181
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-1120

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 1120 mm Impeller weight m 200 kg RZR 13 1026 1/min
Number of blades z 12 Density of media r1 1.2 kg/m
Moment of Inertia J 32 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area!
Pa kW
N all types suitable
N do not use in this area

%
120

80
4000 100

75
69
80 a (N

84
ma
3500 70 x)
60

80
3000
50
2500 40

70
2000 30

60
25

1500 20

50
15

1000 10
1/min m/s

33
8.0
800 7.0 1280 75 1.0
6.0
70
600 5.0 111 dB
1100
a
P

4.0
500 108 60
1000
3.0
400 2.5 105 900
2.0 50
300 102 800
45
99 700
40
200 72
96
600 35
75
No

150
rm

93
al
op
era

500 30
90
tio

78
na
rea

100 0.995
87 450
80 25
84 400
;7

60
A4

350
LW

81
20 0.992
pF

40
N

15000 20000 30000 40000 60000 80000 100000 150000 200000 m/h
Measured in installation B
4 5 6 7 8 9 10 15 20 30 40 50 60 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 40 m/s
v2

3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt 0 3 1 -2 -6 -9 -13 -20 dB 12 7 4 -3 -8 -14 -18 -26 dB
>0.8-1.2 qVopt -1 2 1 -2 -6 -9 -14 -21 dB 10 5 3 -3 -8 -14 -19 -28 dB
682 1/min
>1.2-1.6 qVopt -2 1 1 -3 -5 -8 -15 -21 dB 7 2 3 -3 -6 -13 -20 -28 dB
>1.6 qVopt -5 -3 -2 -3 -5 -7 -14 -21 dB 4 1 2 -3 -6 -12 -19 -28 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -1 -1 -3 -2 -7 -11 -16 -21 dB 10 4 1 -1 -7 -13 -18 -25 dB
>0.8-1.2 qVopt -6 -4 -6 -2 -7 -10 -15 -21 dB 6 2 -2 -3 -6 -12 -15 -25 dB
>682 1/min
>1.2-1.6 qVopt -10 -7 -8 -3 -6 -9 -14 -21 dB 2 -3 -3 -3 -6 -11 -15 -25 dB
>1.6 qVopt -10 -7 -8 -3 -6 -8 -11 -20 dB 1 -3 -5 -3 -6 -11 -13 -22 dB

182
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-1120

Dimensions in mm, subject to change.


RZR 13-1120 710 kg

1890
1020 870
1040
1547
630
1511
1465 110

1421 12

1130 1421
1220

8 125
1130

1240
1174

629
18

2110

55
630
110
922
65m6 200 40

315
11 125

421
870

1487 14
140 1690 110
630
842

LG 0 LG 90 LG 270
2250

2250
2030

1380
140

140
140

1161

1010

S 580 660 340 530 S S 680 190


G41 G42 G44
1537

1537

1537
G5
G5

G5

G0 G90 G270
G2
G2

G2

RD 0 RD 90 RD 270
2250
2250
1161

1380
140

140
140
2030

1010

660 580 S S 530 340 190 680 S


G41 G42 G44
1537

1537

1537
G5

G5

G5

G0 G90 G270
G2

G2

G2

G0 G90 G270 G41 G42 G44 G2 G5 S


112 1870 2040 2040 1310 1480 1480 52.5 410
132 1870 2040 2040 1310 1480 1480 52.5 410
160 2110 2210 2360 1480 1580 1730 410 3
180 2110 2210 2360 1480 1580 1730 410 3
200 2410 2480 2530 1610 1680 1730 510 7
225 2410 2480 2530 1610 1680 1730 510 7
250 2610 2680 2730 1610 1680 1730 660 11
280 2610 2680 2730 1610 1680 1730 660 11
315 2630 2680 2880 1380 1430 1630 760 15
355 2630 2680 2880 1380 1430 1630 760 15

183
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-1250

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 1250 mm Impeller weight m 263 kg RZR 13 957 1/min
Number of blades z 12 Density of media r1 1.2 kg/m
Moment of Inertia J 62.5 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area!
Pa N all types suitable kW
N do not use in this area

%
4000

80
75
69
100 120 a (N
150

84
ma
3500 x)
80
70

80
3000
60
2500 50

70
40
2000

60
30
1500 25

50
20

15
1000
1/min m/s

33
10
800
8.0 1145 75 1.0
7.0 70
600 6.0
111 dB 1000
5.0
500 60
4.0 108 900
400
3.0
800
a
P

2.5 105 50
300
2.0 102 700 45

99 40
200 600
72
96
35
No

150
500
rm

75
93
al
op

30
era

450
tio

90
na

100 0.99
rea

78
400
87 25
80

84 350
60
;7
A4

20 0.98
LW

81 300
pF

40
N

15000 20000 30000 40000 60000 80000 100000 150000 20000 m/h
Measured in installation B
4 5 6 7 8 9 10 15 20 30 40 50 60 70 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 40 m/s
v2

3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt 0 3 1 -2 -6 -9 -13 -20 dB 12 7 4 -3 -8 -14 -18 -26 dB
>0.8-1.2 qVopt -1 2 1 -2 -6 -9 -14 -21 dB 10 5 3 -3 -8 -14 -19 -28 dB
611 1/min
>1.2-1.6 qVopt -2 1 1 -3 -5 -8 -15 -21 dB 7 2 3 -3 -6 -13 -20 -28 dB
>1.6 qVopt -5 -3 -2 -3 -5 -7 -14 -21 dB 4 1 2 -3 -6 -12 -19 -28 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -1 -1 -3 -2 -7 -11 -16 -21 dB 10 4 1 -1 -7 -13 -18 -25 dB
>0.8-1.2 qVopt -6 -4 -6 -2 -7 -10 -15 -21 dB 6 2 -2 -3 -6 -12 -15 -25 dB
>611 1/min
>1.2-1.6 qVopt -10 -7 -8 -3 -6 -9 -14 -21 dB 2 -3 -3 -3 -6 -11 -15 -25 dB
>1.6 qVopt -10 -7 -8 -3 -6 -8 -11 -20 dB 1 -3 -5 -3 -6 -11 -13 -22 dB

184
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-1250

Dimensions in mm, subject to change.


RZR 13-1250 1100 kg

2115
1145 970
1170
1753
750
1693
1653 90

1587 14

1267 1593
1367

7 160
1262

1385
1327

701
20

2355

45
750
1040

90
75m6 200 50

375
9 160

475
970

1653 14
140 1915 90
750
950

LG 0 LG 90 LG 270
2515

2515
2275

1545
160

160
160

1305

1130

S 603 783 388 583 S S 818 153


G41 G42 G44
1713

1713

1713
G5
G5

G5

G0 G90 G270
G2
G2

G2

RD 0 RD 90 RD 270
2515
2515
2275

160

1545

160
160
1305

1130

783 603 S S 583 388 153 818 S


G41 G42 G44
1713

1713

1713
G5

G5

G5

G0 G90 G270
G2

G2

G2

G0 G90 G270 G41 G42 G44 G2 G5 S


112 1965 2220 2255 1405 1660 1695 85 450
132 1965 2220 2255 1405 1660 1695 85 450
160 2235 2390 2525 1605 1760 1895 415
180 2235 2390 2525 1605 1760 1895 415
200 2505 2660 2795 1705 1860 1995 515 2
225 2505 2660 2795 1705 1860 1995 515 2
250 2735 2860 2995 1735 1860 1995 665 6
280 2735 2860 2995 1735 1860 1995 665 6
315 2985 3160 3295 1735 1910 2045 1015 10
355 2985 3160 3295 1735 1910 2045 1015 10

185
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-1400

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 1400 mm Impeller weight m 335 kg RZR 13 870 1/min
Number of blades z 12 Density of media r1 1.2 kg/m
Moment of Inertia J 120 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area!
Pa N all types suitable
N do not use in this area kW

%
4000

80
75
69
120 150 a (N

84
3500 200 ma
100 x)

80
3000
80
2500 70
60

70
2000 50
40

60
1500 30

50
25
20
1000
15
1/min m/s

33
800
1025 75 1.0
10
70
600 8.0
7.0 900
6.0 111 dB
500
60
5.0 800
400 108
a
P

4.0
700 50
3.0 105
300
45
102 600

40
200 99
500
75 35
96
No

150
rm

450
al
op

78 93
era

30
tio

400
na
rea

100 90
350 25
80 87 0.99
81
;7

300
A4

60 84
LW

275 20
0.98
pF

40
N

20000 30000 40000 60000 80000 100000 150000 200000 300000 m/h
Measured in installation B
5 6 7 8 9 10 15 20 30 40 50 60 70 80 90 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 40 m/s
v2

3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 600 800 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt 0 3 1 -2 -6 -9 -13 -20 dB 12 7 4 -3 -8 -14 -18 -26 dB
>0.8-1.2 qVopt -1 2 1 -2 -6 -9 -14 -21 dB 10 5 3 -3 -8 -14 -19 -28 dB
546 1/min
>1.2-1.6 qVopt -2 1 1 -3 -5 -8 -15 -21 dB 7 2 3 -3 -6 -13 -20 -28 dB
>1.6 qVopt -5 -3 -2 -3 -5 -7 -14 -21 dB 4 1 2 -3 -6 -12 -19 -28 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -1 -1 -3 -2 -7 -11 -16 -21 dB 10 4 1 -1 -7 -13 -18 -25 dB
>0.8-1.2 qVopt -6 -4 -6 -2 -7 -10 -15 -21 dB 6 2 -2 -3 -6 -12 -15 -25 dB
>546 1/min
>1.2-1.6 qVopt -10 -7 -8 -3 -6 -9 -14 -21 dB 2 -3 -3 -3 -6 -11 -15 -25 dB
>1.6 qVopt -10 -7 -8 -3 -6 -8 -11 -20 dB 1 -3 -5 -3 -6 -11 -13 -22 dB

186
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-1400

Dimensions in mm, subject to change.


RZR 13-1400 1390 kg

2375
1290 1085
1326
2078
780
1886
1846 220

1780 14

1416 1780
1524

8 160
1416

1550
1481

786
22

110
2635

780
1186

220
85m6 200 50

390
10 160

538
1085

1860 14
170 2190 220
780
1076

LG 0 LG 90 LG 270
2815

2815
2555

1730
180

180
180

1470

1265

S 685 865 400 685 S S 835 250


G41 G42 G44
1920

1920

1920
G5
G5

G5

G0 G90 G270
G2
G2

G2

RD 0 RD 90 RD 270
2815
2815
2555

180

1730
180

180
1470

1265

865 685 S S 685 400 250 835 S


G41 G42 G44
1920

1920

1920
G5

G5

G5

G0 G90 G270
G2

G2

G2

G0 G90 G270 G41 G42 G44 G2 G5 S


160 2225 2550 2580 1505 1830 1860 87 420
180 2225 2550 2580 1505 1830 1860 87 420
200 2495 2800 2950 1605 1910 2060 62 470
225 2495 2800 2950 1605 1910 2060 62 470
250 2775 2960 3160 1775 1960 2160 670 6
280 2775 2960 3160 1775 1960 2160 670 6
315 3055 3230 3410 1805 1980 2160 1020 10
355 3055 3230 3410 1805 1980 2160 1020 10

187
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-1600

Technical Data
Impeller Data Impeller Data Speed limits Nmax for ATEX execution
Impeller diameter Dr 1600 mm Impeller weight m 486 kg RZR 13 748 1/min
Number of blades z 12 Density of media r1 1.2 kg/m
Moment of Inertia J 186 kgm Tolerance class (DIN24166) 1

Performance Curves
Please note coloured area!
Pa N all types suitable
kW
N do not use in this area

80
4000

75
69
200

a
250

84
150

(N m
3500

ax
120

)
80
3000
100
2500
80

70
70
2000 60

60
50

1500 40

50
30
25
1000
20
1/min m/s

33
800 15
900 75 1.0
70
600 10 114 dB 800

500 8.0
7.0 111 60
700
6.0
a

400
P

5.0 108
4.0 600 50
300 105
45
102 500
40
200
99 450
78
35
No

150 400
rm

96
al
op
era

81 30 0.995
tio

93 350
na
rea

100
90
300 25
80
;7
A4

87 0.99
LW

60 84 250
20
pF

40
N

30000 40000 60000 80000 100000 150000 200000 300000 400000 m/h
Measured in installation B
7 8 9 10 15 20 30 40 50 60 70 80 90 100 m/s
qV according to ISO5801:
2 3 4 5 6 7 8 9 10 15 20 30 40 m/s
v2

3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 500 700 1000 Pa


pd2
Relative sound power level for inlet side LWrel7 at octave Relative sound power level for discharge side LWrel4 at
centre frequencies fc octave centre frequencies fc
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt 0 3 1 -2 -6 -9 -13 -20 dB 12 7 4 -3 -8 -14 -18 -26 dB
>0.8-1.2 qVopt -1 2 1 -2 -6 -9 -14 -21 dB 10 5 3 -3 -8 -14 -19 -28 dB
478 1/min
>1.2-1.6 qVopt -2 1 1 -3 -5 -8 -15 -21 dB 7 2 3 -3 -6 -13 -20 -28 dB
>1.6 qVopt -5 -3 -2 -3 -5 -7 -14 -21 dB 4 1 2 -3 -6 -12 -19 -28 dB
Speed Duty point 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz
0.8 qVopt -1 -1 -3 -2 -7 -11 -16 -21 dB 10 4 1 -1 -7 -13 -18 -25 dB
>0.8-1.2 qVopt -6 -4 -6 -2 -7 -10 -15 -21 dB 6 2 -2 -3 -6 -12 -15 -25 dB
>478 1/min
>1.2-1.6 qVopt -10 -7 -8 -3 -6 -9 -14 -21 dB 2 -3 -3 -3 -6 -11 -15 -25 dB
>1.6 qVopt -10 -7 -8 -3 -6 -8 -11 -20 dB 1 -3 -5 -3 -6 -11 -13 -22 dB

188
Belt Driven Centrifugal Fans / RZR / Technical Data

RZR _-1600

Dimensions in mm, subject to change.


RZR 13-1600 1870 kg

2695
1455 1240
1470
2163
980
2103
2063 90

1997 14

1593 2003
1693

9 160
1588

1760
1653

912
22

3000

45
980
1310

90
85m6 200 50

490
12 160

597
1240

2063 14
170 2430 90
980
1194

LG 0 LG 90 LG 270
3200

3200
2895

1960
200

200
200

1655

1440

S 1038 722 502 738 S S 1038 202


G41 G42 G44
2133

2133

2133
G5
G5

G5

G0 G90 G270
G2
G2

G2

RD 0 RD 90 RD 270
3200
3200
2895

200

200
200

1960
1655

1440

722 1038 S S 738 502 202 1038 S


G41 G42 G44
2133

2133

2133
G5

G5

G5

G0 G90 G270
G2

G2

G2

G0 G90 G270 G41 G42 G44 G2 G5 S


160 2736 2786 2901 2016 2066 2181 105.0 425
180 2736 2786 2901 2016 2066 2181 105.0 425
200 3066 3016 3231 2166 2116 2331 75.5 425
225 3066 3016 3231 2166 2116 2331 75.5 425
250 3316 3166 3481 2316 2166 2481 675 1
280 3316 3166 3481 2316 2166 2481 675 1
315 3804 3704 4019 2316 2216 2531 1154 57
355 3804 3704 4019 2316 2216 2531 1154 57

189
Belt Driven Centrifugal Fans / RZR / Specifications

RZR 11-0200/-1000

Specifications
High performance centrifugal fan RZR 11
double inlet belt drive.
Lap jointed scroll of galvanised sheet steel with discharge flange and bolt on multi-
position feet (Size 0200/-0710), with heavy duty side frames (Size 0800/-1000).
High performance impeller with 12 hollow section true airfoil blades (Size
0315/-1000), with 11 backward curved laminar blades (Size 0200/-0280) inclined
obliquely to the shaft axis, welded in position and epoxy coated.
Throat plate inclined obliquely in opposition to blade inclination.
Inlet cones matched to the impeller reduce entry losses to a minimum.
Impeller and shaft balanced as an assembly in according to DINISO1940.
Noise tested maintenance free, radial insert ball bearings mounted in pressed steel
housing/strut assemblies with rubber interliners.
As an option relubricatable in operation within cast iron housings, supported from
the fan casing by tubular struts (0200/-1000).
Performance data to DIN24166 Class 1 / BS848 Class "A" (Size 0315/-1000) or
Class 2 / BS848 Class "B" (Size 0200/-0280).

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Drain plug R1/2" (B.S.P. 1/2")
Access door
Special coating Class S40, K90 or P100
Centrifugal fan in Ex-Execution in Acc. to ATEX
Impeller blades continuously welded
Shaft made of stainless steel (1.4305)
Nuts and bolts of stainless steel (1.4305)
Volumeter
Copper inlet cone
Relubrication in Operation IWN01 or IWN11 (sizes 0200/-0710)

Inlet Guards
Discharge Guard
Shaft guard
Discharge Flange
Discharge Flex (with flexible sleeve)
Base frame with integrated strain-sledge (sizes 0200/-0500)
Base frame with motor rails (sizes 0400/-1000)
Pick-a-Back (for attaching motor fan)
Belt drive, V-belt or flat Belt
Belt guard
Belt guard split horizontally
Motor
Anti-vibration mounts

190
Belt Driven Centrifugal Fans / RZR / Specifications

RZR 12-0200/-0710

Specifications
High performance centrifugal fan RZR 12
double inlet belt drive.
Lap jointed scroll of galvanised sheet steel with discharge flange and rectangular,
angle side frames.
High performance impeller with 12 hollow section true airfoil blades (Size 0315/-0710,
with 11 backward curved laminar blades (Size 0200/-0280) inclined obliquely to the
shaft axis, welded in position and epoxy coated.
Throat plate inclined obliquely in opposition to blade inclination.
Inlet cones matched to the impeller reduce entry losses to a minimum.
Impeller and shaft balanced as an assembly in according to DINISO1940.
Noise tested maintenance free, radial insert ball bearings mounted in pressed steel
housing/strut assemblies with rubber interliners. As an option relubricatable in ope-
ration within cast iron housings, supported from the fan casing by tubular struts.
Performance data to DIN24166 Class 1 / BS848 Class "A" (Size 0315/-0710) or
Class 2 / BS848 Class "B" (Size 0200/-0280).

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Drain plug R1/2" (B.S.P. 1/2")
Access door
Special coating Class S40, K90 or P100
Centrifugal fan in Ex-Execution in Acc. to ATEX
Impeller blades continuously welded
Shaft made of stainless steel (1.4305)
Nuts and bolts of stainless steel (1.4305)
Volumeter
Copper inlet cone
Relubrication in operation IWN01 or IWN11

Inlet Guards
Discharge Guard
Shaft guard
Discharge Flange
Discharge Flex (with flexible sleeve)
Base frame with motor rails
Pick-a-Back (for attaching motor fan)
Belt drive, V-belt or flat Belt
Belt guard
Belt guard split horizontally
Motor
Anti-vibration mounts

191
Belt Driven Centrifugal Fans / RZR / Specifications

RZR 15-0400/-1000

Specifications
High performance centrifugal fan RZR 15
double inlet belt drive.
Lap jointed scroll of galvanised sheet steel with discharge flange and heavy duty
reinforced side frames.
High performance impeller with 12 hollow section true airfoil blades inclined obliquely
to the shaft axis, welded in position and epoxy coated.
Throat plate inclined obliquely in opposition to bladeinclination.
Inlet cones matched to the impeller reduce entrylosses to a minimum.
Impeller and shaft balanced as an assembly in according to DINISO1940.
Self aligning double row ball bearings secured by adapter sleeve, mounted within a
cast iron housing packed with long life, high performance grease. Can be relubricated
when not in service.
Performance data to DIN24166 Class 1 / BS848 Class "A".

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Drain plug R1/2" (B.S.P. 1/2")
Access door
Special coating Class S40, K90 or P100
Impeller blades continuously welded
Shaft made of stainless steel (1.4305)
Nuts and bolts of stainless steel (1.4305)
Tapped hole for measurement of shock impulse
Volumeter
Copper inlet cone
Relubrication in operation IWN01 or IWN11

Inlet Guards
Discharge Guard
Shaft guard
Discharge Flange
Discharge Flex (with flexible sleeve)
Base frame with motor rails
Pick-a-Back (for attaching motor fan)
Belt drive, V-belt or flat Belt
Belt guard
Belt guard split horizontally
Motor
Anti-vibration mounts

192
Belt Driven Centrifugal Fans / RZR / Specifications

RZR 18-0400/-1000

Specifications
High performance centrifugal fan RZR 18
double inlet belt drive.
Lap jointed scroll of galvanised sheet steel with discharge flange and heavy duty
reinforced side frames.
High performance impeller with 12 hollow section true airfoil blades inclined obliquely
to the shaft axis,
welded in position and epoxy coated.
Throat plate inclined obliquely in opposition to blade inclination.
Inlet cones matched to the impeller reduce entry losses to a minimum.
Impeller and shaft balanced as an assembly in according to DINISO1940.
Self aligning double row ball bearings within standard plummer blocks, mounted on
robust pedestal, packed with long life, high performance grease. Can be relubricated
when not in service.
Performance data to DIN24166 Class 1 / BS848 Class "A".

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Drain plug R1/2" (B.S.P. 1/2")
Access door
Special coating Class S40, K90 or P100
Centrifugal fan in Ex-Execution in Acc. to ATEX
Impeller blades continuously welded
Shaft made of stainless steel (1.4305)
Nuts and bolts of stainless steel (1.4305)
Tapped hole for measurement of shock impulse
Volumeter
Copper inlet cone
Relubrication in operation IWN01 or IWN11

Inlet Guards
Discharge Guard
Shaft guard
Discharge Flange
Discharge Flex (with flexible sleeve)
Base frame with motor rails
Pick-a-Back (for attaching motor fan)
Belt drive, V-belt or flat Belt
Belt guard
Belt guard split horizontally
Motor
Anti-vibration mounts

193
Belt Driven Centrifugal Fans / RZR / Specifications

RZR 19-0200/-0355

Specifications
High performance centrifugal fan RZR 19-0200/-0355
double inlet belt drive.
Scroll casing stitch welded with discharge flange and bolt on multi-position feet.
High performance impeller with 12 hollow section true airfoil blades (Size
0315/-0355), with 11 backward curved laminar blades (Size 0200/-0280) inclined
obliquely to the shaft axis, welded in position and epoxy coated.
Throat plate inclined obliquely in opposition to blade inclination.
Inlet cones matched to the impeller reduce entry losses to a minimum.
Impeller and shaft balanced as an assembly in according to DINISO1940.
Noise tested, maintenance free, radial insert ball bearings with spherical outer ring
mounted within castiron housings, supported from the fan casing by tubular struts.
Performance data to DIN24166 Class 1 / BS848 Class "A" (Size 0315/-0355) or
Class 2 / BS848 Class "B" (Size 0200/-0280).

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Drain plug R1/2" (B.S.P. 1/2")
Access door
Special coating Class K90 or P100
Centrifugal fan in Ex-Execution in Acc. to ATEX
Impeller blades continuously welded
Casing continuously welded inside
Casing continuously welded inside and outside
Shaft made of stainless steel (1.4305)
Nuts and bolts of stainless steel (1.4305)
Volumeter
Copper inlet cone
Relubrication in operation IWN01 or IWN11

Inlet Guards
Discharge Guard
Shaft guard
Discharge Flange
Discharge Flex (with flexible sleeve)
Base frame with integrated motor strain-sledge
Pick-a-Back (for attaching motor fan)
Belt drive, V-belt or flat Belt
Belt guard
Belt guard split horizontally
Motor
Anti-vibration mounts

194
Belt Driven Centrifugal Fans / RZR / Specifications

RZR 19-0400/-1000

Specifications
High performance centrifugal fan RZR 19-0400/-1000
double inlet belt drive.
Scroll casing stitch welded with discharge flange, and heavy duty reinforced side
frames, epoxy coated.
High performance impeller with 12 hollow section true airfoil blades inclined obliquely
to the shaft axis, welded in position and epoxy coated.
Throat plate inclined obliquely in opposition to bladeinclination.
Inlet cones matched to the impeller reduce entrylosses to a minimum.
Impeller and shaft balanced as an assembly in according to DINISO1940.
Self aligning double row ball bearings secured by adapter sleeve, mounted within a
cast iron housing packed with long life, high performance grease. Can be relubricated
when not in service.
Performance data to DIN24166 Class 1 / BS848 Class "A".

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Drain plug R1/2" (B. S. P. 1/2")
Access door
Special coating Class K90 or P100
Impeller blades continuously welded
Casing continuously welded inside
Casing continuously welded inside and outside
Casing in 2 horizontal sections (Size 0560 upwards)
Shaft made of stainless steel (1.4305)
Nuts and bolts of stainless steel (1.4305)
Tapped hole for measurement of shock impulse
Volumeter
Copper inlet cone
Relubrication in operation IWN01 or IWN11

Inlet Guards
Discharge Guard
Shaft guard
Discharge Flange
Discharge Flex (with flexible sleeve)
Base frame with motor rails
Pick-a-Back (for attaching motor fan)
Belt drive, V-belt or flat Belt
Belt guard
Belt guard split horizontally
Motor
Anti-vibration mounts

195
Belt Driven Centrifugal Fans / RZR / Specifications

RZR 13-0400/-1000

Specifications
High performance centrifugal fan RZR 13-0400/-1000
double inlet belt drive.
Scroll casing stitch welded with discharge flange and heavy duty reinforced side
frames, epoxy coated.
High performance impeller with 12 hollow section true airfoil blades inclined obliquely
to the shaft axis,
welded in position and epoxy coated.
Throat plate inclined obliquely in opposition to blade inclination.
Inlet cones matched to the impeller reduce entry losses to a minimum.
Impeller and shaft balanced as an assembly in according to DINISO1940.
Self aligning double row ball bearings within standard plummer blocks, mounted on
robust pedestal, packed with long life, high performance grease. Can be relubricated
when not in service.
Performance data to DIN24166 Class 1 / BS848 Class "A".

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Drain plug R1/2" (B.S.P. 1/2")
Access door
Special coating Class K90 or P100
Centrifugal fan in Ex-Execution in Acc. to ATEX
Impeller blades continuously welded
Casing continuously welded inside
Casing continuously welded inside and outside
Casing in 2 horizontal sections (sizes 0500/-1000)
Shaft made of stainless steel (1.4305)
Nuts and bolts of stainless steel (1.4305)
Tapped hole for measurement of shock impulse
Volumeter
Copper inlet cone
Relubrication in operation IWN01 or IWN11

Inlet Guards
Discharge Guard
Shaft guard
Discharge Flange
Discharge Flex (with flexible sleeve)
Base frame with motor rails
Pick-a-Back (for attaching motor fan)
Belt drive, V-belt or flat Belt
Belt guard
Belt guard split horizontally
Motor
Anti-vibration mounts

196
Belt Driven Centrifugal Fans / RZR / Specifications

RZR 13-1120/-1600

Specifications
High performance centrifugal fan RZR 1120/-1600
double inlet belt drive.
Heavy duty casing of sheet steel with stiffening members, step welded and painted,
with discharge flange.
Casing is split on one axis (Size 1120), split on two axis (Sizes 1250, 1400, 1600).
High performance impeller with 12 hollow section true airfoil blades inclined obliquely
to the shaft axis, welded in position and epoxy coated.
Inlet cones matched to the impeller reduce entry losses to a minimum.
Impeller and shaft balanced as an assembly in according to DINISO1940.
Self aligning double row roller bearings within standard plummer blocks, mounted on
robust pedestal, packed with long life, high performance grease. Can be relubricated
when not in service.
Inlet guard fitted as a standard in accordance with DINEN294.
Performance data to DIN24166 Class 1 / BS848 Class "A".

Fan data

Fan type . . . . . . . . . . . . . . . . . . . . . .

Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m/h

Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa

Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa

Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m

Air mediumtemperature t . . . . . . . . . . . . . . . . . . . . . . . . C

Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW

Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . .

Speed N . . . . . . . . . . . . . . . . . . . . . . . . 1/min

Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB

Weight m . . . . . . . . . . . . . . . . . . . . . . . . kg

Fittings / Accessories
Drain plug R1"
Access door
Special coating Class K90 or P100
Centrifugal fan in Ex-Execution in Acc. to ATEX
Impeller blades continuously welded
Casing continuously welded inside
Casing continuously welded inside and outside
Shaft made of stainless steel (1.4305)
Nuts and bolts of stainless steel (1.4305)
Tapped hole for measurement of shock impulse
Volumeter
Copper inlet cone
Relubrication in operation IWN01 or IWN11

Discharge Guard
Shaft guard
Discharge Flange
Discharge Flex (with flexible sleeve)
Base frame with motor rails
Belt drive, V-belt or flat Belt
Belt guard
Belt guard split horizontlly
Motor
Anti-vibration mounts

197
Belt Driven Centrifugal Fans / Notes

Notes

Notes

198
Fittings / Accessories

[1] Mounting feet


[2] Discharge flange
[3] Discharge flex
[4] Inlet guard
[5] Discharge guard
[6] Shaft guard
[7] Mounting flange
[8] Inspection door
[9] Drain plug
A extended corrosion protection
A ATEX-Execution (RZR)
A Impellerblades continuosly welded (RZR)
A Casing continuosly welden-inside (RZR)
A Casing continuosly welden- inside/outside (RZR)
A Split casing (RZR 13/19)
A Shaft from stainless steel
A Nuts and bolts from stainless steel
A Thread for impuls sensor fitting
A Volumeter (RDH / RZR)
A Copper inlet cone
A Aluminium inlet cone (ADH / AT / RDH)
A hot dip galvanised side frame (ADH / RDH)
A relubricatable bearings (relubrication during operation, RZR)

Fan set (ADH / AT / RDH on request)


[10] Base frame
[11] Pick-a-Back
[12] Belt drive
[13] Drive guard
A Belt guard split horizontally
A Access door on belt guard
A Opening on belt guard for speed measuring device
[14] Drive motor
[15] Anti-vibration mounts

199
Gebhardt fan systems the "completely carefree" package for installation fans with belt drive

Fan systems with components tailored for each other, precisely assembled and adjusted, individually tested, delivered quickly and on time, allow
for problem-free processing and ensure long and reliable operation.

Size has its price so we build as small as possible Where required, we deliver our fan systems with safety equipment
complying with DINENISO13857 for safe operation!
A Optimised base frame lengths, tailored to the casing position and
motor size and small system construction heights save valuable e.g. Belt guard
space in the air conditioning unit A also as segmented design
A Various casing and drive positions allow for individual adjustment to A also with inspection hole
the most diverse applications A also with rotation speed measurement opening.
A Optimised flat belt drives allow for efficient operation with a high level
of convenience

Fan set diversity

Version Description Figure

Pick-A-Back for sizes 0200/-0355

Pick-A-Back for sizes 0400/-1000

Compact base frame Integrated compact base frame for sizes up to 0500.

Base Frame, CC-profile Base frames made from CC-profiles with length optimation.

Heavy duty base frame made from U-profiles, welded and painted, from size 0800
Base Frame, U-profile
upward.

200
Belt Driven Centrifugal Fans / Fittings and Accessories

Fittings / Accessories

Drain Plug
If the fan is installed outside, or if conveying a medium containing humidty, condensa-
tion of water may accumulate inside the fan scroll.
For extraction of this water a condense water drain has to be installed at the lowest
point of the scroll.
The drain will be provided with a thread for connecting it to a piping.
At order please indicate the required casing position.
Connecting thread / hole
A ADH / RDH = female thread R1/8"
A AT = drain hole
A RZR 0200/-1000 = male thread R1/2"
A RZR 1120/-1600 = male thread R1"

Dimensions

Inspection Door
For the purposes of maintenance and cleaning there is an opening, which can be
securely closed by means of an access door, in the fan casing.
As it can only be opened with a tool, the access door complies with safety and
accident prevention regulations. Additional securing with locking bars can be supplied
on request.
The site and orientation of the inspection opening depends on the casing position.
The position should be specified when ordering according to the following diagram:
e.g. Access door, Pos. 2.

Inspection Door Positions


Pos.1

Pos.1 Pos.1

Pos.2 Pos.2 Pos.2

Pos.3 Pos.3 Pos.4 Pos.3


ADH / RDH
RZR 0200/-1000 RZR 1120 RZR 1250/-1600

Dimensions in mm, subject to change.


ADH ..- RDH ..- RZR ..-
0160/-0180 100 230 0180 100 230
0200/-0280 240 240 0200/-0280 240 240 0200 160 160
0315/-0560 360 360 0315/-0560 360 360 0225/-0315 210 210
0630/-1000 500 500 0630/-1000 500 500 0355/-1000 310 310
500 500 1120/-1400 500 500 1120/-1600 500 500

201
Belt Driven Centrifugal Fans / Fittings and Accessories

Fittings / Accessories

Corrosion Protection Systems


NicotraGebhardt fans are treated with high quality corrosion protection as standard.
Under extreme operating conditions, however, additional corrosion protection is
advisable.

ADH / AT / RDH
Extended corrosion protection for series ADH, AT and RDH only available on request.

RZR
Depending on the use to which the fan is to be put and the degree of exposure to
corrosion, we offer various anti-corrosion protection measures.

Corrosion protection - Class S40


Degreasing, ironphosphating
A Powder coating Layer thickness 40m, Colour RAL7039
A Wet lacquering Layer thickness 40m (primer + lacquer finish), Colour RAL7039

Corrosion protection - Class K90


Degreasing, ironphosphating
A Powder coating Layer thickness 90m, Colour RAL7039
A Wet lacquerinag Layer thickness 90m (primer + lacquer finish), Colour
RAL7039

Corrosion protection - Class P100


Degreasing, ironphosphating
A Thermoplastic powder coating Layer thickness 100m, Colour RAL7001

Continuously welded blades


Impeller blades can be continuously welded in order to increase the corrosion
resistance when conveying a humid or slightly aggressive medium. The continuous
welding has no influence on the material resistance or on the max. tip speed.

Continuously welded scroll


The casing can be continuously welded in order to increase the corrosion resistance
when conveying a humid or slightly aggressive medium. By continuous welding the
casing is provided with additional impermeability.

A GEH 01 - Casing inside continuously welded


A GEH 02 - Casing inside and outside continuously welded

202
Belt Driven Centrifugal Fans / Fittings and Accessories

Fittings / Accessories

Split Casing
There may be a lot of reasons to choose a split casing, the advantages of split ca-
sings are:
A smaller openings for fan chambers
A easier refitting of fan
A easier transport to site
A easier access to impeller for cleaning and maintenance

The joint face on the casing position runs horizontally above or under the fan axis
(see drawing). The reinforced side frames are not divisible. The fan is supplied fully
assembled.

Dimensions in mm, subject to change.


a c7
c8

t7

t5
h4

h6
t11

t8
w w

RZR
RZR a c7 c8 h4 h6 t5 t7 t8 t11 w
13- 19- 0500 709 822 950 957 783 410 473 409 477 652
13- 19- 0560 785 914 1061 1083 884 458 531 456 530 743
13- 19- 0630 872 1021 1188 1204 984 511 594 510 594 820
13- 19- 0710 967 1143 1331 1350 1100 572 666 571 665 905
13- 19- 0800 1086 1280 1498 1520 1245 640 749 640 749 1035
13- 19- 0900 1219 1439 1686 1707 1386 719 843 720 843 1140
13- 19- 1000 1356 1568 1847 1869 1509 784 923 784 924 1230

Stainless Steel Shaft


For applications where there is an increased risk of corrosion, an optional shaft made
of stainless steel can be supplied.

A ADH / AT / RDH
Stainless steel 1.4301 / AISI 304 / XCrNi18-10
A RZR
Stainless steel 1.4305

Stainless Steel Nuts and Bolts


For applications where there is an increased risk of corrosion, the connecting ele-
ments of the fan can be ordered made of stainless steel.

Impuls Sensor Thread


A tapped hole M6 or M8 can be provided in the pedestal bearing cast housing for
admission of sensors to measure the shock impulses.
(The measuring connecting piece is not included in the scope of delivery).

203
Belt Driven Centrifugal Fans / Fittings and Accessories

Fittings / Accessories

Volumeter
With the flow measuring device it is possible to easily measure/monitor the flow rate
after the fan is installed. A pressure tapping at a predetermined position on the inlet
pin

cone is provided whereby the differential pressure in relation to the static pressure is
measured in front ofthe inlet cone in a static atmosphere.
Permissible media temperature: +80C (RZR), +70C (RDH).

In order to calculate the flow rate, a calibrating factor "K" is required. This factor is
determined by comparativemeasurement on a standard test rig.
2
qV = K pD

Standard-calibration faktor K
Where fans are built into a plenum, the pressure difference between the static pressu-
re in the inlet side plenum and the pressure on the inlet cone is to bemeasured.
It must be ensured that the static pressureto be measured in front of the inlet cone is
not tampered by dynamic pressure fractions.
It is often recommended to arrange a ring of points on the wall facing the outlet side
as illustrated in the sketch.
When using the Kfactors specified below, a minimum clearance of 0.5D between
the inlet cone of the fan and the side wall of the plenum must be maintained.
Indentations that obstruct the flow to the cone canlead to faults when measuring the
Measuring connector in inlet cone flow rate.
Hose pipe to connecting piece in the side wall In the event that the differential pressure is fed via a pressure sensor, the signal can
Connecting piece (external diameter of 6mm) for the pressure also be used for regulating purposes.
measurement

Calibration factors
Standard calibration factor K
Type ms/h
pin

IMV 13-0200 100


IMV 13-0225 115
IMV 13-0250 140
IMV 13-0280 165
IMV 13-0315 190
IMV 13-0355 235
IMV 13-0400 290
IMV 13-0450 360
IMV 13-0500 460
IMV 13-0560 560
IMV 13-0630 730
IMV 13-0710 960
IMV 13-0800 1180
IMV 13-0900 1450
IMV 13-1000 1850
A volume flow qV [m/h] IMV 13-1120 2400
A calibration factor K [ms/h] IMV 13-1250 3000
A density of media r [kg/m] IMV 13-1400 3800
A pressure difference at cone DpD [Pa] IMV 13-1600 4700

Inlet Cones
Inlet cone of copper or aluminium prevent the production of sparks during operation.
These can be employed when spark protection is required, but ATEX is not manda-
tory.

Hot Dip Galvanised Side Frame


Fan Ranges ADH/RDH E4, E6, E7 or K, K1, K2
For applications where an increased corrosion protection is required the reinforcing
side frames of the casing can be executed in hot dip galvanisation as an option.

204
Belt Driven Centrifugal Fans / Fittings and Accessories

Fittings / Accessories

Relubrications
Series RZR
The lubrication unit IWN allows the fan bearings to be greased even when in operati-
on.
The lubrication tubes screwed into the bearing housing are lead out and fastened at
the side wall of the fan.
If desired, the lubrication tubes can be lead to the drive side of the fan.
A IWN 01 - uses standard grease
A IWN 11 - uses moisture resistant grease
ADH / AT / RDH RZR
For more details see "Technical Description" - "Bearings"!

Series ADH / RDH


The bearing housings of the fan ranges ADH / RDH E4, E6, E7 or K, K1, K2 and AT
AR, TIC are equipped with directly fitted grease nipples.

Mounting feet
Feet made from galvanized steel, either mounted or loose, enable the fan to be ins-
talled with a 0, 90 and 270 orientation.

Protection guards
The fans are designed for installation in equipment and as standard are not equipped
with protective guards.
They should not be put into operation before all protective devices are fitted
and connected!
Protective measures must be carried out as set out in DINENISO12100 "Safety of
machinery - Basic concepts, general principles for design".
If the application of the fan allows free access to the inlet and discharge apertures,
safety devices must be put in place on the fan in accordance with DINENISO13857!
Suitable safety guards are available as an optional extra.

Shaft Guards
Contact guard for the free end of the shaft for double inlet centrifugal fans. Models in
accordance with DINENISO13857, made of painted steel mesh.

Flanges
Made from galvanized or painted steel, to connect ducts and system components to
the fan outlet side.

Flexible Connections
Connecting piece with elastic intermediate section for the vibration or impact-noise
decoupled connection of the fan to the system or unit. Made out of two connecting
flanges with elastic intermediate section.

Temperature range / Application


A Standard up to +80C
A ATEX max. +60C

205
Belt Driven Centrifugal Fans / Fittings and Accessories

Fittings / Accessories

Anti Vibration Mounts


AV mounts are designed to prevent noise and vibrations being transmitted through
the base of the fan.

AV mounts should be mounted beneath the fan base frame so the weight and
spring deflections are evenly distributed. They should not be mounted symmetrically
because a counter force is induced into the system by the pressure created by the
working fan.

It is difficult for the manufacturer to establish the position of the AV mounts to suit all
types of application.

Vibration and noise insulation can also be improved by ensuring that the fan is con-
nected to its external environment by a flexible coupling.

Rubber pads and buffers for both vibration and noise insulation at fan speeds
Fastening for CC-profile Fastening for U-profile above 1400rpm or 850rpm.

Rubber buffers for noise insulation only at fan speeds under 800rpm or 1700rpm.

Spring diffusers with noise insulation layer and height adjustment, for both vibration
and noise insulation at fan speeds above 400rpm.

Available AV mounts for different fans, see proSELECTAII.


The AVM-mounts are supplied with the suitable mounting material for the
base frame.

Anti Vibration Rubber Pads


H ZBD ZBD A B C D E G H
21-6035A* 21-6035C* 60 45 35 30 20 5 M6
21-6065A* 21-6065C* 60 45 35 30 20 6 M6
21-5935A* 21-5935C* 90 70 50 45 32 9 M10
21-5950A* 21-5950C* 90 70 50 45 32 9 M10
E

* A = for U-profile, C = for CC-profile


A
C
D
G

Anti Vibration Rubber Buffers


ZBD ZBD A E F G H K
H 01-0405A* 01-0405C* 20 25 16 M 6 M 6 6.5
F

03-0503A* 03-0503C* 25 15 11 M 6 M 6 6.5


01-0504A* 01-0504C* 25 20 11 M 6 M 6 6.5
E

03-0806A* 03-0806C* 40 30 21 M 8 M 8 9.5


03-1007A 03-1007C* 50 34 26.5 M 10 M 10 10.5
K

G 03-1510A* 03-1510C* 75 50 39 M 12 M 12 12.5


02-2008A* 02-2008C* 100 40 44 M 16 M 16 16.5

* A = for U-profile, C = for CC-profile


A

206
Belt Driven Centrifugal Fans / Fittings and Accessories

Fittings / Accessories

Anti Vibration Spring Diffusers


H ZBD ZBD A B C D ~E ~F G H
60-0101A* 60-0101C* 130 100 70 72 70-50 35 13 M10
60-0103A* 60-0103C* 130 100 70 72 70-50 35 13 M10
60-0105A* 60-0105C* 130 100 70 72 70-50 35 13 M10
60-0108A* 60-0108C* 130 100 70 72 70-50 35 13 M10

E
60-0112A* 60-0112C* 150 120 82 92 90-75 35 13 M12
60-0120A* 60-0120C* 150 120 82 92 90-75 35 13 M12
60-0130A* 60-0130C* 150 120 82 92 90-75 35 13 M12
60-0150A* 60-0150C* 150 120 82 92 110-85 35 13 M12

* A = for U-profile, C = for CC-profile

G
B
A

Anti Vibration Spring Diffusers


M8 ZBD ZBD
SP-7701A* SP-7701C*
SP-7702A* SP-7702C*
SP-7703A* SP-7703C*
SP-7704A* SP-7704C*
~60

SP-7705A* SP-7705C*
SP-7706A* SP-7706C*
SP-7707A* SP-7707C*
M8
* A = for U-profile, C = for CC-profile
45

Anti Vibration Spring Diffusers


ZBD ZBD
M10
50

SP-7501A* SP-7501C*
SP-7502A* SP-7502C*
SP-7503A* SP-7503C*
~106

SP-7504A* SP-7504C*
SP-7505A* SP-7505C*
SP-7506A* SP-7506C*
SP-7507A* SP-7507C*
SP-7508A* SP-7508C*
70

95

* A = for U-profile, C = for CC-profile


11

120
150

Anti Vibration Spring Diffusers


H ZBD ZBD E H kg
80-W603A* 80-W603C* 68-101 M 16 8.3
80-W605A* 80-W605C* 76-101 M 16 8.6
80-W608A* 80-W608C* 86-105 M 16 9.0
80-W612A* 80-W612C* 84-104 M 16 9.3
E

80-W616A* 80-W616C* 92-105 M 24 9.7

* A = for U-profile, C = for CC-profile


14
200

240
270

207
Belt Driven Centrifugal Fans / Fan Set

Fan Sets

Base Frame with Belt Tensioning Device


G2Z-component size 0200/-0500 (only RZR 11/19)
This compact base frame with integrated motor tensioning slider provides optimum
compactness and easiest handling.
A The base frame made of galvanized sheet steel is screwed directly onto the fan
(without any casing feet) the result being the low overall height of the system.
A The overall length depending on the casing position and size of the motor is a
further factor influencing the optimum compactness.
A The integrated tensioning slider considerably simplifies re-adjustment of the belt
drive during maintenance and service work.

G1Z-component size 0400/-0710


The base frames up to motor size 180 are manufactured from galvanized CC-profiles.
The anti-vibration mounts in the CC-profile provide infinitely variable adjustment.
From motor size 200 the base frames are of U-profile, welded and painted.
Fitted motor tensioning tracks that allow the motor to be shifted longitudinally, allow
for the simple adjustment of the belt tension.

G1Z-component size 0800/-1600


Base frame of stable U-profiles, welded and painted, with holes for attaching the anti-
vibration mounts.
Fitted motor tensioning tracks that allow the motor to be shifted longitudinally, allow
for the simple adjustment of the belt tension.

Equipment
A FKS hot-dip galvanized for U-profile base frame

Pick-A-Back
This allows the motor to be fixed directly onto the fan casing, where space around
the fan is limited. One side of the pick-a-back is fixed to the casing so that it swivels,
while the other is supported on a spindle. Thus the pick-a-back becomes adjustab-
le to leave room for tensioning the drive belt. The various motor arrangements and
casing positions are shown in the drawings.
The accompanying tables also show the maximum permissible motor sizes.
When using a pick-a-back arrangement and fitting anti vibration mounts (AVM) an
additional base frame for fitting the AVM may be required depending on the position
of the centre of gravity of the whole fan set.

208
Belt Driven Centrifugal Fans / Fan Set

Fan Sets

Belt Drive
Wedge Belts
High performance narrow V-belts in accordance with DIN7753 are temperature stab-
le up to +80C, resistant to mineral oils and electrostatically conductive.
The belt pulleys are made of high quality cast iron and, depending on the peripheral
velocity and number of grooves, are statically (G16) or dynamically (G6.3) balanced.
They are fastened to the shaft of the motor or fan by means of a clamping bush.

Flat Belts
The flat belt drives employed are made using the most modern technology and mate-
rials. They are the centrepiece of highly developed, powerful belt drives.
This modern flat belt drive has distinct advantages over traditionally employed V-belt
drives and exceeds it in efficiency, quiet running and economy.

Overview of the advantages:


A higher efficiency
A longer service life
A quieter running
A easy to install
A low maintenance
A no wear on the belt - so it is possible to dispense with the 2nd filter stage in the air
conditioning unit (in accordance with VDI6022)

Belt Guard
Totally enclosed belt guards are made from galvanised sheet steel in accordance with
DINDINENISO13857.
The front section can be removed for maintenance. If there is no standard belt guard
available for the selected belt drive (see table), a suitable belt guard will be made as a
welded construction and then coated.

Features
A belt guard split horizontally
A access door on belt guard
A opening on belt guard for speed measuring device

Dimensions in mm, subject to change.


l3 u4 RBS a7max DWmax b8 b7 s5 u4 u3 l4 l3
01-....-01 250 90 194 159 97 72 69 444 404
01-....-02 300 90 194 159 97 72 69 494 454
01-....-03 350 160 264 229 132 72 69 614 574
~b7
b8

01-....-04 400 160 264 229 132 72 69 664 624


01-....-05 450 160 264 229 132 72 69 714 674
01-....-06 500 160 264 229 132 72 69 764 724
a7 ~u3
01-....-07 600 160 264 229 132 72 69 864 824
l4
01-....-08 700 125 264 229 132 72 69 964 924
01-....-09 800 125 264 229 132 72 69 1064 1024
01-....-10 900 125 264 229 132 72 69 1164 1124
01-....-11 450 250 344 304 172 122 119 794 754
01-....-12 500 250 344 304 172 122 119 844 804
01-....-13 600 250 344 304 172 122 119 944 904
01-....-14 700 315 484 444 242 122 119 1184 1144
01-....-15 800 315 484 444 242 122 119 1284 1244
01-....-16 900 315 484 444 242 122 119 1384 1344
01-....-17 1000 315 484 444 242 122 119 1484 1444
01-....-18 1100 315 484 444 242 122 119 1584 1544
01-....-19 1200 315 484 444 242 122 119 1684 1644

.... Spaceholder for fan- DWmax Diameter of the biggest a7max Maximum axle centre
size pulley distance

209
Belt Driven Centrifugal Fans / Fan Set

RZR 11-0200/-0500

Fan set arrangement with base frame


Dimensions in mm, subject to change.
LG 0 G LG 90 G RD 0 G RD 90 G
L90 L90
L0 L0

H90

H90
H0

H0
G0 G90 G0 G90

LG 180 G
LG LG 270 G RD 180 G
RD RD 270 G
L270 L270
L180 L180

H270
H270

H180
H180

P180 G270 P180 G270


G180 G180

G2Z
L2

X2

X2

2 2 2 2
RZR RZR G0 G90 G180 G270 H0 H90 H180 H270
11- 19- 0200 625 650 880 650 358 408 356 386
11- 19- 0225 680 710 925 710 404 467 401 431
11- 19- 0250 705 730 974 730 440 510 438 477
11- 19- 0280 725 755 1031 755 489 569 485 531
11- 19- 0315 750 785 1094 785 542 623 537 597
11- 19- 0355 845 885 1207 885 603 689 601 670
11- 0400 990 970 1350 970 671 773 667 749
11- 0450 1030 1010 1440 910 755 868 750 840
11- 0500 1070 1050 1530 1050 827 956 821 929

2 2 2 2 Motor Base frame ~ kg


RZR RZR L0 L90 L180 L270 L2 P180 X2 max.
11- 19- 0200 745 740 880 740 100 396 286 132 6
11- 19- 0225 793 792 925 792 100 423 322 132 7
11- 19- 0250 843 829 974 829 100 450 356 132 7.5
11- 19- 0280 893 876 1031 876 100 482 395 132 8
11- 19- 0315 952 931 1094 931 100 520 438 132 9
11- 19- 0355 1087 1090 1207 1060 100 552 487 160 10
11- 0400 1219 1120 1350 1120 120 587 546 180 11
11- 0450 1315 1203 1440 1203 120 646 612 180 12
11- 0500 1400 1279 1530 1279 120 700 680 180 14

2 The base frame length has been determined with the always largest admitted motor size. With smaller motors the frame length will be redu-
ced.
For accurate dimensions use proSELECTAII or on request.

210
Belt Driven Centrifugal Fans / Fan Set

RZR 11-0400/-0710

Fan set arrangement with base frame


Dimensions in mm, subject to change.

LG 0 G LG 90 G RD 0 G RD 90 G

H90

H90
H0
H0

P2 P1 P2 P1
G3

G3

G3
G3
G0 G90 G0 G90

LG 180 G
LG
LG 270 G RD 180 G
RD RD 270 G

H270
H270

H180
H180

P3 P4 P3 P4
G3
G3

G3
G3
G180 G270 G180 G270

G1Z (CC) G1Z (U)


L2

X2 X2

X2 Anti-vibration mounts are supplied with


AV brackets included.

2 2 2 2 G3 for motor size


RZR G0 G90 G180 G270 63-71 80-90 100-132 160-180 200-225 250-280
11- 0400 1240 1300 1650 1240 82-CC 82-CC 82-CC 82-CC 80-U 3
11- 0450 1300 1350 1740 1298 82-CC 82-CC 82-CC 82-CC 80-U 3
11- 0500 1434 1405 1772 1405 82-CC 82-CC 82-CC 82-CC 80-U 3
11- 0560 1558 1508 1908 1508 82-CC 82-CC 82-CC 82-CC 80-U 3
11- 0630 1600 1574 2006 1574 82-CC 82-CC 82-CC 80-U 3
11- 0710 1708 1680 2145 1680 82-CC 82-CC 82-CC
11- 0710-U 1700 1700 2115 1700 100-U 120-U 3

Motor Base frame ~ kg


RZR H0 H90 H180 H270 L2 P1 P2 P3 P4 X2 max. CC 80-U 100-U
11- 0400 671 773 667 749 120 275 355 669 275 550 225 31 3 3
11- 0450 755 868 750 840 120 320 408 718 320 614 225 32 3 3
11- 0500 827 956 821 929 120 348 452 766 348 682 225 33 60
11- 0560 921 1071 914 1041 150 384 502 851 384 759 225 34 63
11- 0630 1028 1195 1021 1168 150 432 566 915 432 846 225 35 68
11- 0710 1152 1341 1143 1316 180 479 625 1014 479 943 180 37
11- 0710-U 1152 1341 1143 1316 180 943 250 94 145

2 The base frame length has been determined with the always largest 3 Dimensions on request
admitted motor size. With smaller motors the frame length will be
reduced.
For accurate dimensions use proSELECTAII or on request.

211
Belt Driven Centrifugal Fans / Fan Set

RZR 12-0200/-0710

Fan set arrangement with base frame


Dimensions in mm, subject to change.
LG 0 G LG 90 G RD 0 G RD 90 G

H90

H90
H0
H0

P2 P1 P2 P1
G0 G90 G0 G90
G3

G3

G3
G3
LG 180 G
LG LG 270 G RD 180 G
RD RD 270 G

H270
H270

H180
H180

P3 P4 P3 P4
G180 G270 G180 G270
G3
G3

G3
G3
G1Z (CC) G1Z (U)
L2

X2 X2

X2 Anti-vibration mounts are supplied with


AV brackets included.

2 2 2 2 G3 for motor size


RZR G0 G90 G180 G270 63-71 80-90 100-132 160-180 200-225 250-280
12- 0200 4 4 4 4
12- 0225 4 4 4 4
12- 0250 4 4 4 4
12- 0280 4 4 4 4
12- 0315 4 4 4 4
12- 0355 4 4 4 4
12- 0400 1430 1312 1655 1312 82-CC 82-CC 82-CC 82-CC 80-U 3
12- 0450 1522 1388 1740 1388 82-CC 82-CC 82-CC 82-CC 80-U 3
12- 0500 1610 1460 1830 1460 82-CC 82-CC 82-CC 82-CC 80-U 3
12- 0560 1736 1561 1958 1561 82-CC 82-CC 82-CC 82-CC 80-U 3
12- 0630 1865 1670 2078 1670 82-CC 82-CC 82-CC 80-U 3
12- 0710 2008 1784 2235 1784 82-CC 82-CC 82-CC
12- 0710-U 2035 1840 2235 1840 100-U 120-U 3

Motor Base frame ~ kg


RZR H0 H90 H180 H270 L2 X2 max. CC 80-U 100-U
12- 0200 4 4 4 4 4 4 4 4 4 4
12- 0225 4 4 4 4 4 4 4 4 4 4
12- 0250 4 4 4 4 4 4 4 4 4 4
12- 0280 4 4 4 4 4 4 4 4 4 4
12- 0315 4 4 4 4 4 4 4 4 4 4
12- 0355 4 4 4 4 4 4 4 4 4 4
12- 0400 669 769 669 750 120 550 225 31 3 3
12- 0450 753 865 753 841 120 614 225 32 3 3
12- 0500 825 955 825 931 120 682 225 33 60
12- 0560 920 1067 920 1046 150 759 225 34 63
12- 0630 1027 1195 1027 1173 150 846 225 35 68
12- 0710 1152 1341 1152 1324 180 943 180 37
12- 0710-U 1152 1341 1152 1324 180 250 94 155

2 The base frame length has been determined with the always largest 3 Dimensions on request
admitted motor size. With smaller motors the frame length will be 4 The RZR 12-0200 to 0355 can only be supplied as standard basic
reduced. models.
For accurate dimensions use proSELECTAII or on request.

212
Belt Driven Centrifugal Fans / Fan Set

RZR 13-0400/-1000
RZR 18-0400/-1000
Fan set arrangement with base frame
Dimensions in mm, subject to change.
LG 0 G LG 90 G RD 0 G RD 90 G

H90

H90
H0
H0

P2 P1 P2 P1
G0 G90 G0 G90
G3

G3

G3
G3
LG 180 G
LG LG 270 G RD 180 G
RD RD 270 G

H270
H270

H180
H180

P3 P4 P3 P4
G180 G270 G180 G270
G3
G3

G3
G3
G1Z (CC) G1Z (U)
L2

X2 X2

X2 Anti-vibration mounts are supplied with


AV brackets included.

G0 G90 G180 G270 G3 for motor size


RZR RZR CC2 U CC2 U CC2 U CC2 U 63-71 80-90 100-132 160-180 200-225 250-280
13- 18- 0400 1240 1300 1650 1240 82-CC 82-CC 82-CC 82-CC 80-U 3
13- 18- 0450 1300 1350 1740 1298 82-CC 82-CC 82-CC 82-CC 80-U 3
13- 18- 0500 1411 1411 1772 1411 82-CC 82-CC 82-CC 82-CC 80-U 3
13- 18- 0560 1468 1468 1908 1468 82-CC 82-CC 82-CC 82-CC 80-U 3
13- 18- 0630 1564 1564 2006 1564 82-CC 82-CC 82-CC 80-U 3
13- 18- 0710 1660 1700 1660 1700 2145 2115 1660 1700 82-CC 82-CC 82-CC 100-U 120-U 3
13- 18- 0800 2300 2300 2885 2300 80-U 80-U 80-U 100-U 120-U
13- 18- 0900 2410 2410 3052 2410 80-U 80-U 80-U 100-U 120-U
13- 18- 1000 2505 2505 3180 2505 80-U 80-U 80-U 100-U 120-U

Motor Base frame ~ kg


RZR RZR H0 H90 H180 H270 L2 P1 P2 P3 P4 X2 max. CC 80-U 100-U 120-U
13- 18- 0400 671 775 671 775 170 290 290 669 290 550 225 31 3 3 3
13- 18- 0450 755 868 755 868 170 316 316 718 316 614 225 32 3 3 3
13- 18- 0500 827 957 827 957 170 345 345 766 345 682 225 33 60
13- 18- 0560 921 1083 921 1083 210 382 382 851 382 759 225 34 63
13- 18- 0630 1028 1204 1028 1204 210 410 410 915 410 846 225 35 68
13- 18- 0710 1152 1350 1152 1350 240 464 464 1014 464 943 250 37 94 155
13- 18- 0800 1290 1520 1290 1520 250 518 518 1155 518 1048 250 67 98 155
13- 18- 0900 1448 1707 1448 1707 260 570 570 1276 570 1179 280 72 105 165
13- 18- 1000 1577 1869 1577 1869 260 620 620 1317 620 1316 280 77 111 165

2 The base frame length has been determined with the always largest 3 Dimensions on request
admitted motor size. With smaller motors the frame length will be
reduced.
For accurate dimensions use proSELECTAII or on request.

213
Belt Driven Centrifugal Fans / Fan Set

RZR 11-0800/-1000 RZR 19-0400/-1000


RZR 15-0400/-1000
Fan set arrangement with base frame
Dimensions in mm, subject to change.
LG 0 G LG 90 G RD 0 G RD 90 G

H90

H90
H0
H0

P2 P1 P2 P1
G0 G90 G0 G90
G3

G3

G3
G3
LG 180 G
LG LG 270 G RD 180 G
RD RD 270 G

H270
H270

H180
H180

P3 P4 P3 P4
G180 G270 G180 G270
G3
G3

G3
G3
G1Z (CC) G1Z (U)
L2

X2 X2

X2 Anti-vibration mounts are supplied with


AV brackets included.

G0 G90 G180 G270 G3 for motor size


RZR RZR RZR CC2 U CC2 U CC2 U CC2 U 63-71 80-90 100-132 160-180 200-225 250-280
15- 19- 0400 1240 1300 1650 1240 82-CC 82-CC 82-CC 82-CC 80-U 3
15- 19- 0450 1300 1350 1740 1298 82-CC 82-CC 82-CC 82-CC 80-U 3
15- 19- 0500 1411 1411 1772 1411 82-CC 82-CC 82-CC 82-CC 80-U 3
15- 19- 0560 1468 1468 1908 1468 82-CC 82-CC 82-CC 82-CC 80-U 3
15- 19- 0630 1564 1564 2006 1564 82-CC 82-CC 82-CC 80-U 3
15- 19- 0710 1660 1700 1660 1700 2145 2115 1660 1700 82-CC 82-CC 82-CC 100-U 120-U 3
11- 15- 19- 0800 2300 2300 2885 2300 80-U 80-U 80-U 100-U 120-U
11- 15- 19- 0900 2410 2410 3052 2410 80-U 80-U 80-U 100-U 120-U
11- 15- 19- 1000 2505 2505 3180 2505 80-U 80-U 80-U 100-U 120-U

Motor Base frame ~ kg


RZR RZR RZR H0 H90 H180 H270 L2 P1 P2 P3 P4 X2 max. CC 80-U 100-U 120-U
15- 19- 0400 671 775 671 775 170 290 290 669 290 550 225 31 3 3 3
15- 19- 0450 755 868 755 868 170 316 316 718 316 614 225 32 3 3 3
15- 19- 0500 827 957 827 957 170 345 345 766 345 682 225 33 60
15- 19- 0560 921 1083 921 1083 210 382 382 851 382 759 225 34 63
15- 19- 0630 1028 1204 1028 1204 210 410 410 915 410 846 225 35 68
15- 19- 0710 1152 1350 1152 1350 240 464 464 1014 464 943 250 37 94 155
11- 15- 19- 0800 1290 1520 1290 1520 250 518 518 1155 518 1048 250 67 98 155
11- 15- 19- 0900 1444 1707 1444 1707 260 570 570 1276 570 1179 280 72 105 165
11- 15- 19- 1000 1573 1869 1573 1869 260 620 620 1317 620 1316 280 77 111 165

2 The base frame length has been determined with the always largest 3 Dimensions on request
admitted motor size. With smaller motors the frame length will be
reduced.
For accurate dimensions use proSELECTAII or on request.

214
Belt Driven Centrifugal Fans / Fan Set

AT 7/7-18/18

Fan set arrangement with Pick-A-Back


Using these specially designed motor brackets, the motor can be fixed, Pick-A-Back,
directly on the scroll of the S-version fans.
When the motor must be held on the fan side-frames, the customer will need provi-
ding an appropriate slide or bracket, to connect it to the fixing holes on the standard
frames.

Motor positions

Version 1 Version 2

0 90

180 270

Permissible Motor Power


Version 1 Version 2
Article- Max. permissible Article- Max. permissible
Size code motor power code motor power
AT kW kW
7/7 687303 0.75 687940
9/7 687303 0.75 687940 1.1
9/9 687308 0.75 687941 1.1
10/8 687312 0.75 687942 1.5
10/10 687314 0.75 687943 1.5
12/9 687318 0.75 687944 2.2
12/12 687320 0.75 687945 2.2
15/11 687335 0.75 687546 3.0
15/15 687338 0.75 687947 3.0
18/13 687346 0.75 687948 3.0
18/18 687348 0.75 687949 3.0

215
Belt Driven Centrifugal Fans / Fan Set

RZR 11-0200/-0710
RZR 19-0200/-0355
Fan set arrangement with Pick-A-Back
Dimensions in mm, subject to change.
LG 90/1 RD 90/1
H15 H15

H17 LG 0/1 H17


LG 90/2 RD 0/1 RD 90/2

H16
H16
LG 0/3 RD 0/3
H16 H16

LG 180/2
LG LG 270/3 RD 180/2
RD RD 270/3
H15 H15
H16 H16

LG 180/3 RD 180/3

H17

H15
H15

H17
LG 180/1 RD 180/1

LG 270/2 RD 270/2
H17 H17

X1 L1

1 1 1 Motor Weight
RZR RZR ~ H15 ~ H16 ~ H17 L1 X1 max. ~ kg
11- 19- 0200 650 720 680 100 286 90 1
11- 19- 0225 700 760 720 100 322 100 2
11- 19- 0250 750 850 810 100 356 100 2
11- 19- 0280 860 930 890 100 395 112 3
11- 19- 0315 880 970 960 100 438 112 3
11- 19- 0355 960 1080 1070 100 487 112 3
11- 0400 1280 1290 1280 120 546 132 8
11- 0450 1330 1430 1380 120 612 132 8
11- 0500 1360 1470 1560 120 680 132 8
11- 0560 1510 1630 1740 150 756 132 11
11- 0630 1660 1800 1820 150 843 160 12
11- 0710 1810 1960 2010 180 940 160 17

1 This dimensions have been calculated with the largestappropriate


applicable motor in mind.

216
Belt Driven Centrifugal Fans / Fan Set

RZR 12-0200/-0710

Fan set arrangement with Pick-A-Back


Dimensions in mm, subject to change.

H15 H15
LG 90/1 RD 90/1
H17 H17
LG 0/1 RD 0/1
LG 90/2

H16
RD 0/3

H16
RD 90/2
LG 0/3
H16 H16

LG 180/2
LG LG 270/3 RD 180/2
RD RD 270/3
H15 H15
H16 H16

LG 180/3 RD 180/3

H17

H15
H15

H17
LG 180/1 RD 180/1

LG 270/2 RD 270/2
H17 H17

X1 L1

1 1 1 Motor Weight
RZR ~ H15 ~ H16 ~ H17 ~ L1 X1 max. ~ kg
12- 0200 670 670 690 100 286 90 1
12- 0225 710 730 780 100 322 100 1
12- 0250 850 840 860 100 356 100 2
12- 0280 880 920 930 100 395 112 2
12- 0315 950 950 1030 100 438 112 3
12- 0355 1080 1090 1130 100 487 112 3
12- 0400 1190 1290 1280 120 546 132 7
12- 0450 1330 1430 1390 120 612 132 7
12- 0500 1360 1470 1560 120 680 132 8
12- 0560 1500 1620 1630 150 756 132 11
12- 0630 1650 1790 1810 150 843 160 12
12- 0710 1800 1950 2000 180 940 160 17

1 This dimensions have been calculated with the largestappropriate


applicable motor in mind.

217
Belt Driven Centrifugal Fans / Fan Set

RZR 13-0400/-1000
RZR 18-0400/-1000
Fan set arrangement with Pick-A-Back
Dimensions in mm, subject to change.

LG 90/1 RD 90/1

H16
H16
LG 180/2
LG LG 270/3 RD 180/2
RD RD 270/3

H17

H15
H15

H17
X1 L1

1 1 1 Motor Weight
RZR RZR ~ H15 ~ H16 ~ H17 ~ L1 X1 max. ~ kg
13- 18- 0400 1280 1300 1300 170 548 132 10
13- 18- 0450 1320 1430 1380 170 612 132 11
13- 18- 0500 1350 1560 1550 170 683 132 12
13- 18- 0560 1530 1700 1730 210 759 160 15
13- 18- 0630 1640 1870 1820 210 845 160 16
13- 18- 0710 1800 1970 2010 240 942 160 23
13- 18- 0800 1970 2150 2150 250 1053 160 30
13- 18- 0900 2150 2400 2350 260 1179 160 33
13- 18- 1000 2230 2630 2550 260 1317 160 36

1 This dimensions have been calculated with the largestappropriate


applicable motor in mind.

218
Belt Driven Centrifugal Fans / Fan Set

RZR 11-0800/-1000 RZR 19-0400/-1000


RZR 15-0400/-1000
Fan set arrangement with Pick-A-Back
Dimensions in mm, subject to change.

LG 90/1 RD 90/1

H16
H16
LG 180/2
LG LG 270/3 RD 180/2
RD RD 270/3

H17

H15
H15

H17
X1 L1

1 1 1 Motor Weight
RZR RZR RZR ~ H15 ~ H16 ~ H17 ~ L1 X1 max. ~ kg
15- 19- 0400 1280 1300 1300 170 548 132 10
15- 19- 0450 1320 1430 1380 170 612 132 11
15- 19- 0500 1350 1560 1550 170 683 132 12
15- 19- 0560 1530 1700 1730 210 759 160 15
15- 19- 0630 1640 1870 1820 210 845 160 16
15- 19- 0710 1800 1970 2010 240 942 160 23
11- 15- 19- 0800 1970 2150 2150 250 1053 160 30
11- 15- 19- 0900 2150 2400 2350 260 1179 160 33
11- 15- 19- 1000 2230 2630 2550 260 1317 160 36

1 This dimensions have been calculated with the largestappropriate


applicable motor in mind.

219
Belt Driven Centrifugal Fans / Fan Set

Fan Sets

Min. Pulley-Diameter, Bearings Life Expectency


As a principle, the fans are only equipped with noise tested precision bearings desig-
ned for a nominal bearing life time (L10h acc. to DINISO281-1) of 40,000 operating
hours.
In order to not exceed the admitted bearing loads there are minimum pulley diameters
defined to be respected when sizing the belt drive.
The minimum pulley diameters indicated are to be applied for belt drives
selected according to the state of the art and tensioned according to the
prescriptions.
For flat belt drives the minimum pulley diameters are to be increased of 40%
to the indicated figure!
A correct design of a belt drive may be achieved with our selection software where all
relevant parameters will be kept automatically.
For correct design of a belt drive made by external means, dimensioning and the
application of the tensioning forces have to made in full respect of all specification
data indicated.

Wedge Belts
LT = Shaft Centres
b = Defection of belt in mm under test force Fp
LT / LT Fp = Test force N as prescribed by NicotraGebhardt-Document
2

LT / Belt Tensioning
2
The correct tension is achieved when the test force Fp results in a deflection of
16mm / metre of span.

F
b

Flat Belts
* LMu = Measuring Marks 1 before Tensioning
L LMg = Measuring Marks 1 After Tensioning
Mg
e* = Stretching Values as specified by NicotraGebhardt-Document
L
Mu
Belt Tensioning
The correct belt tension is achieved when the measuring marks LMu have increased
by the stretching value e*. This should be carried out in two stages to prevent over-
stressing of the bearing.

Wedge- and Flat Belts


A further simple method for setting or checking the correct belt tension is via the
static frequency of the drive belt.
=
Here the flat or V-belt is set to oscillate freely through striking it whilst stationary.
These vibrations are measured using an electronic measuring unit (e.g. a belt tension
= gauge). The vibration frequency in Hz must then be set to the specified value (docu-
mentation / nameplate).

1 = Measuring point

Detailed instruction on tensioning are included within the operating and


maintenance manuals.

220
Belt Driven Centrifugal Fans / Fan Set

Fan Sets

Min. recommended Pulley Diameter for ADH


Nominal motor power in kW
Fan size Fan model
2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75
E0 / E2 63 71
160
G2E0 / E2 63 71
E0 / E2 63 80
180
G2E0 / E2 63 80
E0 / E2 / E4 71 95 125
200
G2E0 / E2 71 95 140
E0 / E2 / E4 80 112 140
225
G2E0 / E2 80 100 160
E0 / E2 80 112 150
E4 90 112 140 180
250 G2E0 / E2 80 100 132
G2E4 95 125 160 224
G2E7 100 118 160
E0 / E2 100 140 180
E4 90 112 140 212
280 G2E0 / E2 112 140 180
G2E4 100 118 150 224
G2E7 112 112 140 180 224
E0 / E2 100 125 180
E4 90 125 160 250
E6 160 224 250
315
G2E0 / E2 112 140 200
G2E4 112 140 180 250
G2E7 160 190 212 300
E0 / E2 100 132 180
E4 112 150 224 280
E6 125 180 224 236
355
G2E0 / E2 112 140 200
G2E4 112 150 224 280
G2E7 160 180 212 300
E0 / E2 100 132 180
E4 112 150 224 280
E6 140 180 212 250
400
G2E0 / E2 100 132 180
G2E4 100 140 200 280
G2E7 160 190 250 300
E0 / E2 112 132 212
E4 118 180 250
E6 180 212 250 315
450
G2E0 / E2 118 140 200
G2E4 112 160 224
G2E7 160 180 250 300
E0 / E2 112 132 200
E4 112 180 224
E6 150 190 224 315
500 E7 180 250 315
G2E0 / E2 118 140 200
G2E4 112 160 224
G2E7 180 212 250 300
E0 / E2 132 180 224
E4 150 200 236
E6 160 190 250
560 E7 160 180 212 236
G2E2 132 180 212
G2E4 132 180 224
G2E7 160 224 250 280
L/R 132 160 215
K 132 200 224
K1 160 180 250
630 K2 160 180 200 224
G2R 132 180 200
G2K 132 180 224
G2K2 180 224 280 355
L/R 132 150 180 250
K 132 180 224 250
K1 180 212 236
710
K2 180 200 224 280
G2K 160 190 212
G2K2 180 200 224 224 280
K 180 224 250
K1 180 212 236
800 K2 180 200 224 250
G2K 180 200 212
G2K2 180 200 224 224 280
K 160 180 224
K1 212 236 280
900 K2 200 224 224 280
G2K 180 200 236
G2K2 200 224 224 280
K 180 212 280
K2 200 224 224 280
1000
G2K 180 200 250
G2K2 180 190 224 280
221
Belt Driven Centrifugal Fans / Fan Set

Fan Sets

Min. recommended Pulley Diameter for AT


Nominal motor power in kW
Fan size Fan model
1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55
S / SC 63 63 80 112
7/7
G2L / SC2 63 63 90 118
S / SC 63 63 85 112
AR 80 100 140 200
9/7
G2L / SC2 63 63 90 125
G2C 71 80 100 150
S / SC 63 90 125
AR 85 112 150 224
9/9
G2L / SC2 63 71 95 132
G2C 80 112 150
S / SC 63 71 85 112
AR 80 100 150 200
10/8
G2L / SC2 63 71 95 132
G2C 80 100 150
S / SC 71 95 125 180
AR 85 118 160 224
10/10
G2L / SC2 63 80 112 140
G2C 90 125 180
S / SC 71 90 118 180
AR 85 118 160 236
12/9 G2L / SC2 85 95 118 180
G2C 80 90 118 224
G3C 100 112 118 180
S / SC 90 112 140 200
AR 100 140 190 280
12/12 G2L / SC2 80 112 140 200
G2C 85 112 140 200
G3C 90 112 140 200
S / SC 85 112 132 180
AR 90 118 160 236
15/11 G2L / SC2 80 100 140 200
G2C 85 112 150 224
G3C 100 118 180 250
S / SC 80 100 132 180
AR 95 132 180 250
15/15 G2L / SC2 80 100 132 180
G2C 85 100 132 200
G3C 100 118 160 224
S / SC 100 132 180 250
AR 100 140 200 280
18/13 G2L / SC2 95 125 180 250
G2C 95 112 160 224
G3C 100 112 160 224
S / SC 100 132 180 250
AR 100 132 190 280
18/18 G2L / SC2 90 118 180 224
G2C 95 112 160 224
G3C 100 112 140 200
TIC 100 140 200 280
G2C 112 160 250 280
20/15 G2C-C2 150 180 200 224
G3C 112 150 200 280
G3C-C2 150 180 200 224
TIC 100 132 200 280
G2C 112 150 224 250
20/20 G2C-C2 150 180 200 224
G3C 112 140 200 250
G3C-C2 150 180 200 224
TIC 100 132 200 280
G2C 112 160 224 280
22/15 G2C-C2 150 180 200 224
G3C 112 140 200 250
G3C-C2 150 180 200 224
TIC 100 132 200 280
G2C 112 150 224 280
22/22 G2C-C2 150 180 200 224
G3C 112 140 200 250
G3C-C2 150 180 190 224
TIC 90 118 160 224
G2C 112 140 200
25/20 G2C-C2 250 150 180 190 224
G3C 112 132 200
G3C-C2 224 150 180 190 224
TIC 112 150 224
G2C 112 140 200 250
25/25 G2C-C2 150 180 190 224 224
G3C 112 132 180 224
G3C-C2 150 180 190 224 224
TIC 100 150 200 250
G2C 112 132 180 224
28/20 G2C-C2 150 180 190 224 224
G3C 112 132 180 224
G3C-C2 150 180 190 224 224
TIC 100 140 200 250
G2C 112 132 180 224
28/28 G2C-C2 150 180 190 224 224
G3C 112 125 160 200
G3C-C2 150 180 190 224 224
TIC 100 140 200 250
G2C 100 132 180 224
30/20 G2C-C2 150 180 190 212 224
G3C 100 125 180 224
G3C-C2 150 180 190 224 224
TIC 100 140 200 250
G2C 100 125 180 224
30/28 G2C-C2 150 180 190 212 224
G3C 100 125 160 200
G3C-C2 150 180 190 224 224
222
Belt Driven Centrifugal Fans / Fan Set

Fan Sets

Min. recommended Pulley Diameter for RDH


Nominal motor power in kW
Fan size Fan model
2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75
0180 E0 / E2 63 63
0200 E0 / E2 / E4 63 63
0225 E0 / E2 / E4 63 63 71
E0 / E2 71 80
E4 71 71 90
0250
G2E4 80 80 90
G2E7 85 112
E0 / E2 80 100
E4 90 100
0280 G2E0 / E2
G2E4 90 100
G2E7 90 125
E0 / E2 90 118
E4 90 112
E6 90 100
0315
G2E0 / E2
G2E4 80 90
G2E7 90 112
E0 / E2 85 100 112
E4 90 112 125
E6 100 112 118
0355
G2E0 / E2
G2E4 90 125
G2E7 90 112
E0 / E2 112 140
E4 100 132 180
0400 E6 118 140 150
G2E4 100 112 112
G2E7 112 125 160
E0 / E2 112 125 180
E4 112 140 180
0450 E6 125 140 160 212
G2E4 100 118 140
G2E7 112 125 160
E0 / E2 125 132 160
E4 132 150 200
E6 140 140 150 200
0500
E7 118 125 150 200
G2E4 100 118 150
G2E7 140 150 180
E0 / E2 140 180 224
E4 150 200 224
E6 150 160 212
0560 E7 140 160 160
G2E2
G2E4 112 140
G2E7 180 200 280
R 140 180 250
K 150 200 250
K1 180 180 236
0630
K2 150 180 190 224
G2K 140 190
G2K2 180 200 280 355
R 180 224
K 224 250 315
K1 180 224 250
0710
K2 200 212 224
G2K 180 200 280
G2K2 224 224 280
K 200 250 280
K1 180 212 250
0800 K2 212 224 224
G2K 180 190 250
G2K2 224 250 280
K 160 180 250
K1 212 250 280
0900 K2 224 224 280
G2K 224 250 315
G2K2 224 224 280
K 180 236 315
K2 224 224 300
1000
G2K 190 224 280
G2K2 224 224 280
223
Belt Driven Centrifugal Fans / Fan Set

Fan Sets

Min. recommended Pulley Diameter for RZR


Nominal motor power in kW
Fan size Fan model
3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 250
0200 11 / 12 / 19 71 71 71 90

0225 11 / 12 / 19 71 71 80 100

0250 11 / 12 / 19 71 71 90 112

11 / 12 71 71 90 118
0280
19 71 71 71 85 112

11 / 12 71 85 106 132
0315
19 71 71 75 95 125

11 / 12 75 95 118 150
0355
19 71 71 85 106 140

11 / 12 71 80 100 125
0400
13 / 15 / 18 / 19 71 71 71 71 85 106 125 140 180

11 / 12 71 90 112 140
0450
13 / 15 / 18 / 19 71 71 71 71 95 118 140 160 200

11 / 12 80 100 125 160


0500
13 / 15 / 18 / 19 71 71 71 80 106 132 160 180 224

11 / 12 71 71 85 112 150 190


0560
13 / 15 / 18 / 19 71 71 71 71 90 112 132 150 190 224

11 / 12 71 80 100 132 180 224


0630
13 / 15 / 18 / 19 71 71 71 75 100 125 150 170 224 250

11 / 12 71 85 112 140 190 236 280


0710
13 / 15 / 18 / 19 71 71 71 71 85 106 118 140 180 212 250 280

11 80 100 125 160 224 280 315 355


0800
13 / 15 / 18 / 19 71 71 71 71 95 118 140 160 212 236 280 315

11 95 118 150 200 280 355 400 450


0900
13 / 15 / 18 / 19 71 71 71 71 85 106 125 140 180 212 250 300 375

11 112 140 180 224 315 400 450 500


1000
13 / 15 / 18 / 19 71 71 71 71 95 118 140 160 212 236 280 315 425

1120 13 315 315 315 315 315 315 315 315 355 355 400 450

1250 13 315 315 315 315 315 315 315 315 355 355 400 400 450

1400 13 315 315 315 315 315 315 315 315 355 355 400 400 450 450

1600 13 315 315 315 315 315 315 315 315 355 355 400 400 450 500 560

For flat-belt-drives the listed recommended pulley diameter mus be enlarged up to approx. 40%.

224
Belt Driven Centrifugal FansBelt Driven Centrifugal Fans / Description

Description

General
The high-performance centrifugal fans are the result of extensive and systematic
development work.
These technically first-rate products are distinguished by their high efficiency, the
large pressure differences attainable and low noise levels.
The sizes are geometrically scaled in accordance with the standard range R20 and
the nominal size stated is the external diameter of the impeller.

Media
The fans are suitable for handling air and other non aggressive gases from -20C up
to +80C, resp. +100C.
The ambient temperature at the drive motor must not exceed +40C.

Protective installations
The fans are designed for installation in equipment and as standard are not equipped
with protective guards.
They should not be put into operation before all protective devices are fitted
and connected!
Protective measures must be carried out as set out in DINENISO12100 "Safety of
machinery - Basic concepts, general principles for design".
If the application of the fan allows free access to the inlet and discharge apertures,
safety devices must be put in place on the fan in accordance with DINENISO13857!
Suitable safety guards are available as an optional extra.

Shafts
Shafts ADH / AT / RDH
The fan shafts are manufacrured of ground, precisely rounded carbon steel C40.
They are principally prepared without being stepped at both ends.
The shafts of the RDH K1 and K2 ranges, size 1000 are machined on both ends for
fitting a pulley.
ADH / AT from size 12/9 / RDH
The shafts are equipped with a keyway (open shape) at both ends and a key (type2).
AT 7/7 up to 10/10
The standard construction is the version with flats on shaft ends (type1), it is also
available the version with keyways (type2).
For corrosion protection the shafts are galvanised up to fan size 0560 and 30/28.
From size 0630 and larger the shaft are covered, between bearing and hub, with a
paint in order to ensure corrosion protection.
The shaft ends are covered with a wax product easy to remove.

Shafts RZR
The shafts are manufacured of precisely rounded carbon steel C35, pared and polis-
hed.
Up to size 1000 they are not stepped at the shaft end.
For sizes 1120 up to 1600 the shafts are machined on both ends for fitting a pulley.
The shafts are equipped with a keyway at both ends and a key executed according to
DIN6885-1.
A Groove shape N2 (open) Sizes 0200 up to 1000
A Groove shape N1 Sizes 1120 up to 1600

The shafts are covered with a easily removable wax product for corrosion protection.

Housig feet / Side frames ADH / AT / RDH


For easier installation of the fan the mounting feet and reinforcing frames are provided
with eye holes.

225
Belt Driven Centrifugal FansBelt Driven Centrifugal Fans / Description

Description

Bearings ADH / AT / RDH


ADH E0 / ADH L Maintenance free, self aligning radial insert ball bearings,
ADH E2 / ADH R mounted in pressed steel housing/strut assemblies with
AT S / AT SC rubber interliners.
AT G2L / AT SC2
RDH E0
RDH E2 / RDH R

ADH E4 / ADH K Monobloc pedestal cast iron pillow block bearings with
AT AR / AT TIC / AT relubrication nipple, mounted on a robust frame.
G2C Integrated, maintenance free self aligning radial ball
RDH E4 / RDH K bearings, fixed by eccentric clamp.

ADH E6 / ADH K1 / Pilow block cast iron bearings with relubrication nipple,
ADH E7-0500 mounted on a robust frame. Integrated self aligning
RDH E6 / RDH K1 / radial ball bearings, fixed by conical sleeve and locknut.
RDH E7-0500

ADH E7-0560; Split-type plummer block bearings with relubrication


ADH K2-0630/-0800 nipple, mounted on a robust frame, integrated self ali-
AT G2C-C2 gning double row ball-bearings fixed by conical sleeve,
RDH E7-0560; lubricated with long life high performance grease.
RDH K2-0630/-0800

ADH K2-0900-1000 Single piece plummer block housing, with grease


RDH K2-0900-1000 nipple, mounted on robust pedestal, equipped with self
RDH X1 aligning double row roller bearing, fixed to impeller shaft
RDH X2 by a concentric shaft clamp, lubricated with long life
high performance grease.

Twin Fans The twin fans up to size 0630 are equipped with one
single shaft and 3 bearings. From size 0710 the two
separate fans are connected by an elastic coupling.
For the models G2K2 the bearings from size 0710 and
larger are due to different loads of a different execu-
tion inside compared to outside.

226
Belt Driven Centrifugal Fans / Description

Description

Bearings RZR
RZR 11-0200/-1000; Radial insert ball bearings with spherical outer Ring
RZR 12-0200/-0710 mounted in pressed steel housing/strut assemblies with
(without lubricators) rubber interliners.

RZR 11-0200/-0710; Radial insert ball bearings with spherical outer Ring
RZR 12-0200/-0710 mounted within cast iron housing, supported from the
(with relubricators) fan casing by tubular struts. Relubrication is effected via
extended tubes and nipples.

RZR 19-0200/-0355 Radial insert ball bearings with spherical outer Ring
(without lubricators) mounted within cast iron housing, supported from the
fan casing by tubular struts.

RZR 19-0200/-0355 Relubrication is effected via extended tubes


(with relubricators) and nipples.

RZR 15-0400/-1000; Self aligning double row ball bearings secured by adap-
RZR 19-0400/-1000 ter sleeve, mounted within a cast iron housing.
(without lubricators)

RZR 15-0400/-1000; Relubrication is effected via extended tubes


RZR 19-0400/-1000 and nipples.
(with relubricators)

RZR 13-0400/-1600; Self aligning double row ball bearings within standard
RZR 18-0400/-1000 plummer blocks, mounted on robust pedestal.
(without lubricators)

RZR 13-0400/-1600; Relubrication is effected via extended tubes


RZR 18-0400/-1000 and nipples.
(with relubricators)

Lubricators for relubrication during operation


The Bearings are charged with long life high performance grease. Relubrication is
effected via extended tubes and nipples.
See operating and maintenance instructions.

A IWN 01 - Standard grease, Gadus S2 V100 3


A IWN 11 - Klber-Staburags NBU12/300KP

227
Belt Driven Centrifugal Fans / Description

Description

Motors
Standard motors of wellknown brands, type of protection IP55, thermal class F, are
used. During commissioning and maintenance the detailed instructions provided by
the motor manufacturer (type plate/motor operating instructions) must be followed,
this also applies to the motor protection devices required onsite. The motors are
equipped with PTC resistors/temperature sensors as standard. Motors with integra-
ted frequency inverters may be supplied on request.

EX-ATEX motors
Fan sets of centrifugal fans according to Ex-ATEX execution are equipped with mo-
tors of the correspondent category.
For frequency inverter operation the motors will be of pressure resistant execution.

Speed regulation
A suitable speed variation system is required for the optimum adjustment of the
desired operating point.
Our frequency converters are perfectly tuned for the operation of RZR centrifugal fans.
The use of the newest power semi-conductors guarantees high efficiency and mini-
mum motor noise thanks to the especially fine pulse pattern.
See also the technical description "Performance".

Electric connection
Centrifugal fan systems are delivered ready for installation. The motor terminal box
can be easily accessed.
Electric installation must be carried out according to the applicable provisions in
compliance with local regulations. A terminal board circuit diagram showing correct
connection is enclosed with every motor.

Attachment points on the side plates ADH/RDH


ADH/RDH 0160/-0180
a a b c d e f g h m n p r s
g d 0160 281 291 205 141 119 172 140 30 92 121 67 155 101 4
m p 0180 310 326 229 157 131 195 153 30 92 141 81 175 115 4
hh
f
c

r
n

m
b

hh
p
s
e

hh
m
s

ADH/RDH 0200/-0250
a a b c d e f g h m n
g d 0200 341 362 256 177 147 215 164 40 110 155
m z
h h 0225 379 407 288 199 165 242 180 40 110 184
0250 416 452.5 322 221 183.5 269 195 40 110 209

p r s t u v z x
r
f
v
c
n

0200 134 202 129 163 126 190 94 91 4


m

0225 152 229 149 185 142 219 114 107 4


b

h h

0250 171 256 172 208 155 244 137 120 4


x
u
p
e

h h
m
s
t

228
Belt Driven Centrifugal Fans / Description

Description

Attachment points on the side plates ADH/RDH


ADH/RDH 0280/-0315
a b c d e f g h m n p r s t u v
a 0280 464 508 361 249 206 302 215 113 71 170 191 287 169 233 150 245 6.2
g d
h h 0315 515 571 404 279 232 339 236 113 71 195 215 323 197 263 175 284 6.2

Scroll dimensions are refered to the external surface of the back plate

r
f
v
c

h
b

h
u
p
e
n

m h
s
t

ADH/RDH 0355/-0450
a b c d e f g h m
a 0355 576 643 453 315 261 382 261 156 158
g d
o s 0400 644 733 507 354 302 431 290 156 186
h h 0450 721 817.5 569 399 332.5 485 322 213 168

n o p r s t u v
0355 197.5 197.5 241 364 204 295 158 295 6.2
r
f
v
c

0400 220 230 275 411 243 336 186 346 6.2
n

h
b

0450 245 256 311 466 271 379 168 350 M10
h
m

u
p
e

Scroll dimensions are refered to the external surface of the back plate
m h
t

ADH/RDH 0500
a a b c d e f g h m n
g d 0500 794 906 638 442 368 538 352 231 439 220
o s
h h
w w o p r s t u v k w
0500 281 349 519 280 423 207 400 354 181 M10

Scroll dimensions are refered to the external surface of the back plate
r
f
m
c

v
k
n

h
b

h
u
u

p
e

h h
t

ADH/RDH 0560/-0710
a a b c d e f g h m n o
g d 0560 886 1016 715 496 413 603 390 235 490 245 310
o s 0630 993 1142 801 559 463 679 434 235 553.5 260 353
h h
w w 0710 1119 1295 898 634 530 765 485 265 626.5 267.5 393

p r s t u v z x k w
0560 389 581 362 472 276 494 310 140 394 180 M10
f
r

0630
m

441 656 431 521 328 567 356 160 M10


c

v
k
n

0710 496 737 476 605 371 637 397 200 M10
h
b

h
u
u

Scroll dimensions are refered to the external surface of the back plate
p
e

h h
z t

Screw to be used to attach mounting feet


Size Type of screw Thread
0160/-0250 Self-threading screw AB 6.3 ISO 1478
0280/-0400 Self-threading screw AB 8 ISO 1478
0450/-0710 Metric screw M10 ISO 724

229
Belt Driven Centrifugal Fans / Description

Description

Operating limits ADH


Permissible Permissible Permissible Permissible Fan Permissible Permissible Permissible Permissible Fan
nominal fan speed bearing media weight nominal fan speed bearing media weight
motor load temperature motor load temperature
power power
ADH kW 1/min N C kg ADH kW 1/min N C kg
E0-0160 3 4200 420 -20 / +80 5 E0-0500 11 1200 1180 -20 / +80 57
E2-0160 3 4200 420 -20 / +80 6.6 E2-0500 11 1200 1180 -20 / +80 65
G2E0-0160 3 3400 420 -20 / +80 10.5 E4-0500 15 1300 1320 -20 / +100 85
G2E2-0160 4 3400 420 -20 / +80 14.5 E6-0500 30 1400 1800 -20 / +100 86
E0-0180 3 4000 420 -20 / +80 6 E7-0500 37 1400 2200 -20 / +100 105
E2-0180 3 4000 420 -20 / +80 7.8 G2E0-0500 11 900 1180 -20 / +80 120
G2E0-0180 3 3200 420 -20 / +80 12.6 G2E2-0500 11 900 1180 -20 / +80 140
G2E2-0180 4 3200 420 -20 / +80 17 G2E4-0500 15 1000 1320 -20 / +100 176
E0-0200 4 3800 420 -20 / +80 7.1 G2E7-0500 45 1400 4000 -20 / +100 221
E2-0200 4 3800 420 -20 / +80 9.1 E0-0560 15 1100 1450 -20 / +80 72
E4-0200 4 3800 420 -20 / +100 12.6 E2-0560 15 1100 1450 -20 / +80 86
G2E0-0200 4 2900 420 -20 / +80 15 E4-0560 18.5 1200 1760 -20 / +100 134
G2E2-0200 4 2900 420 -20 / +80 20 E6-0560 30 1300 2550 -20 / +100 142
E0-0225 4 3400 420 -20 / +80 8.5 E7-0560 45 1300 3700 -20 / +100 150
E2-0225 4 3400 420 -20 / +80 10.7 G2E2-0560 15 800 1450 -20 / +80 185
E4-0225 4 3400 420 -20 / +100 14.5 G2E4-0560 18.5 900 1760 -20 / +100 268
G2E0-0225 4 2600 420 -20 / +80 18 G2E7-0560 45 1200 4000 -20 / +100 319
G2E2-0225 4 2600 420 -20 / +80 24 L-0630 15 900 1450 -20 / +80 91
E0-0250 4 2800 420 -20 / +80 10.5 R-0630 15 900 1450 -20 / +80 106
E2-0250 4 2800 420 -20 / +80 13 K-0630 18.5 1000 1760 -20 / +100 170
E4-0250 7.5 3000 450 -20 / +100 18 K1-0630 30 1100 2550 -20 / +100 175
G2E0-0250 4 2200 420 -20 / +80 22 K2-0630 45 1100 3700 -20 / +100 180
G2E2-0250 4 2200 420 -20 / +80 29 G2R-0630 15 700 1450 -20 / +80 230
G2E4-0250 7.5 2300 450 -20 / +100 38 G2K-0630 18.5 750 1760 -20 / +100 342
G2E7-0250 15 2800 1250 -20 / +100 44 G2K2-0630 55 1000 4000 -20 / +100 393
E0-0280 5.5 2500 530 -20 / +80 14.2 L-0710 18.5 750 1800 -20 / +80 118
E2-0280 5.5 2500 530 -20 / +80 18 R-0710 18.5 750 1800 -20 / +80 135
E4-0280 11 2700 660 -20 / +100 24 K-0710 22 850 1900 -20 / +100 201
G2E0-0280 5.5 2000 530 -20 / +80 30 K1-0710 37 900 3550 -20 / +100 208
G2E2-0280 5.5 2000 530 -20 / +80 39 K2-0710 55 900 5800 -20 / +100 225
G2E4-0280 11 2200 660 -20 / +100 50 G2K-0710 30 700 3000 -20 / +100 532
G2E7-0280 22 2400 1700 -20 / +100 59 G2K2-0710 75 800 7000 -20 / +100 537
E0-0315 5.5 2100 530 -20 / +80 18 K-0800 22 750 1900 -20 / +100 249
E2-0315 5.5 2100 530 -20 / +80 22 K1-0800 37 800 3550 -20 / +100 261
E4-0315 11 2400 660 -20 / +100 29 K2-0800 55 800 5800 -20 / +100 278
E6-0315 18.5 2400 1050 -20 / +100 30 G2K-0800 30 600 3000 -20 / +100 665
G2E0-0315 5.5 1600 530 -20 / +80 38 G2K2-0800 75 700 7000 -20 / +100 670
G2E2-0315 5.5 1600 530 -20 / +80 48 K-0900 30 650 3000 -20 / +100 306
G2E4-0315 11 1900 660 -20 / +100 60 K1-0900 45 700 3900 -20 / +100 316
G2E7-0315 30 2100 2000 -20 / +100 73 K2-0900 75 700 7000 -20 / +100 320
E0-0355 7.5 1800 840 -20 / +80 23 G2K-0900 37 500 3000 -20 / +100 801
E2-0355 7.5 1800 840 -20 / +80 29 G2K2-0900 75 600 7000 -20 / +100 806
E4-0355 15 2000 940 -20 / +100 41 K-1000 37 600 3000 -20 / +100 333
E6-0355 22 2000 1450 -20 / +100 42 K1-1000 45 600 3900 -20 / +100 356
G2E0-0355 7.5 1500 840 -20 / +80 49 K2-1000 75 650 7000 -20 / +100 360
G2E2-0355 7.5 1500 840 -20 / +80 63 G2K-1000 37 450 3000 -20 / +100 894
G2E4-0355 15 1700 940 -20 / +100 84 G2K2-1000 75 500 7000 -20 / +100 899
G2E7-0355 30 1900 2000 -20 / +100 98
E0-0400 7.5 1600 840 -20 / +80 31
E2-0400 7.5 1600 840 -20 / +80 38
E4-0400 15 1800 940 -20 / +100 52
E6-0400 22 1800 1450 -20 / +100 53
G2E0-0400 7.5 1200 840 -20 / +80 66
G2E2-0400 7.5 1200 840 -20 / +80 82
G2E4-0400 15 1400 940 -20 / +100 108
G2E7-0400 37 1800 2950 -20 / +100 133
E0-0450 11 1400 1180 -20 / +80 42
E2-0450 11 1400 1180 -20 / +80 50
E4-0450 15 1500 1320 -20 / +100 66
E6-0450 30 1500 1800 -20 / +100 67
G2E0-0450 11 1000 1180 -20 / +80 90
G2E2-0450 11 1000 1180 -20 / +80 107
G2E4-0450 15 1200 1320 -20 / +100 135
G2E7-0450 37 1400 2950 -20 / +100 159

230
Belt Driven Centrifugal Fans / Description

Description

Operating limits AT
Permissible Permissible Permissible Permissible Fan Permissible Permissible Permissible Permissible Fan
nominal fan speed bearing media weight nominal fan speed bearing media weight
motor load temperature motor load temperature
power power
AT kW 1/min N C kg AT kW 1/min N C kg
S-7/7 3 2600 350 -20 / +85 5 S-18/13 7.5 1200 620 -20 / +85 27
SC-7/7 3 2600 350 -20 / +85 6 SC-18/13 7.5 1200 620 -20 / +85 33
G2L-7/7 3 2400 350 -20 / +85 11.7 AR-18/13 15 1200 1200 -20 / +100 33
SC2-7/7 3 2600 350 -20 / +85 13.7 G2L-18/13 7.5 1100 620 -20 / +85 57.8
S-9/7 3 2500 350 -20 / +85 6.6 SC2-18/13 7.5 1200 620 -20 / +85 69.8
SC-9/7 3 2500 350 -20 / +85 8.3 G2C-18/13 15 1200 1600 -20 / +100 91
AR-9/7 7.5 2500 620 -20 / +100 8.3 G3C-18/13 15 1000 1600 -20 / +100 118
G2L-9/7 3 2400 350 -20 / +85 14.9 S-18/18 7.5 1100 620 -20 / +85 32.5
SC2-9/7 3 2500 350 -20 / +85 18 SC-18/18 7.5 1100 620 -20 / +85 38.2
G2C-9/7 7.5 2500 1000 -20 / +100 23.5 AR-18/18 15 1100 1200 -20 / +100 38.2
S-9/9 3 2100 350 -20 / +85 7.9 G2L-18/18 7.5 800 620 -20 / +85 70.5
SC-9/9 3 2100 350 -20 / +85 9.5 SC2-18/18 7.5 800 620 -20 / +85 81.9
AR-9/9 7.5 2100 620 -20 / +100 9.5 G2C-18/18 15 1000 1600 -20 / +100 106
G2L-9/9 3 2000 350 -20 / +85 18.1 G3C-18/18 15 700 1600 -20 / +100 137
SC2-9/9 3 2100 350 -20 / +85 21.8 TIC-20/15 15 1300 1200 -20 / +100 71
G2C-9/9 7.5 2100 1000 -20 / +100 27 G2C-20/15 18.5 1300 1600 -20 / +100 137
S-10/8 3 2500 350 -20 / +85 8.3 G2CC2-20/15 45 1300 6500 -20 / +100 144
SC-10/8 3 2500 350 -20 / +85 9.8 G3C-20/15 18.5 900 1600 -20 / +100 315
AR-10/8 7.5 2500 620 -20 / +100 9.8 G3CC2-20/15 45 1100 6500 -20 / +100 319
G2L-10/8 3 2100 350 -20 / +85 18.5 TIC-20/20 15 1300 1200 -20 / +100 78
SC2-10/8 3 2500 350 -20 / +85 21.8 G2C-20/20 18.5 900 1600 -20 / +100 150
G2C-10/8 7.5 2500 1000 -20 / +100 27 G2CC2-20/20 45 1200 6500 -20 / +100 158
S-10/10 4 2000 350 -20 / +85 9.3 G3C-20/20 18.5 700 1600 -20 / +100 355
SC-10/10 4 2000 350 -20 / +85 11 G3CC2-20/20 45 800 6500 -20 / +100 359
AR-10/10 7.5 2000 620 -20 / +100 11 TIC-22/15 15 1300 1200 -20 / +100 73
G2L-10/10 3 1800 350 -20 / +85 21.1 G2C-22/15 18.5 1300 1600 -20 / +100 141
SC2-10/10 3 2000 350 -20 / +85 23.5 G2CC2-22/15 45 1300 6500 -20 / +100 148
G2C-10/10 7.5 1700 1000 -20 / +100 31 G3C-22/15 18.5 800 1600 -20 / +100 340
S-12/9 5.5 2000 620 -20 / +85 12.7 G3CC2-22/15 45 1000 6500 -20 / +100 347
SC-12/9 5.5 2000 620 -20 / +85 16 TIC-22/22 15 1200 1200 -20 / +100 82.5
AR-12/9 11 2000 1000 -20 / +100 16 G2C-22/22 18.5 900 1600 -20 / +100 165
G2L-12/9 5.5 1800 620 -20 / +85 28.2 G2CC2-22/22 45 1000 6500 -20 / +100 173
SC2-12/9 5.5 2000 620 -20 / +85 34.8 G3C-22/22 18.5 600 1600 -20 / +100 425
G2C-12/9 11 2000 1200 -20 / +100 45.5 G3CC2-22/22 45 800 6500 -20 / +100 438
G3C-12/9 11 2000 1200 -20 / +100 70 TIC-25/20 15 1000 1600 -20 / +100 93
S-12/12 5.5 1500 620 -20 / +85 15.2 G2C-25/20 18.5 700 1600 -20 / +100 195
SC-12/12 5.5 1500 620 -20 / +85 18.4 G2CC2-25/20 45 800 6500 -20 / +100 202
AR-12/12 11 1500 1000 -20 / +100 18.4 G3C-25/20 18.5 600 1600 -20 / +100 432
G2L-12/12 5.5 1400 620 -20 / +85 33.8 G3CC2-25/20 45 700 6500 -20 / +100 436
SC2-12/12 5.5 1500 620 -20 / +85 40.2 TIC-25/25 15 900 1600 -20 / +100 105
G2C-12/12 11 1400 1200 -20 / +100 51 G2C-25/25 18.5 700 1600 -20 / +100 202
G3C-12/12 11 1400 1200 -20 / +100 81 G2CC2-25/25 55 800 6500 -20 / +100 210
S-15/11 5.5 2000 620 -20 / +85 17.7 G3C-25/25 18.5 500 1600 -20 / +100 480
SC-15/11 5.5 2000 620 -20 / +85 20.9 G3CC2-25/25 55 600 6500 -20 / +100 484
AR-15/11 11 2000 1000 -20 / +100 20.9 TIC-28/20 18.5 800 1600 -20 / +100 120
G2L-15/11 5.5 1400 620 -20 / +85 39.7 G2C-28/20 18.5 600 1600 -20 / +100 210
SC2-15/11 5.5 2000 620 -20 / +85 46.1 G2CC2-28/20 55 800 7000 -20 / +100 218
G2C-15/11 11 1500 1200 -20 / +100 57.4 G3C-28/20 18.5 600 1600 -20 / +100 474
G3C-15/11 15 1500 1600 -20 / +100 90 G3CC2-28/20 55 650 7000 -20 / +100 478
S-15/15 5.5 1200 620 -20 / +85 20.6 TIC-28/28 18.5 800 1600 -20 / +100 127
SC-15/15 5.5 1200 620 -20 / +85 24.5 G2C-28/28 18.5 600 1600 -20 / +100 235
AR-15/15 11 1200 1000 -20 / +100 24.5 G2CC2-28/28 55 700 7000 -20 / +100 244
G2L-15/15 5.5 1100 620 -20 / +85 45.3 G3C-28/28 18.5 400 1600 -20 / +100 539
SC2-15/15 5.5 1200 620 -20 / +85 53.1 G3CC2-28/28 55 550 7000 -20 / +100 543
G2C-15/15 11 950 1200 -20 / +100 68 TIC-30/20 18.5 800 1600 -20 / +100 131
G3C-15/15 15 1000 1600 -20 / +100 108 G2C-30/20 18.5 600 1600 -20 / +100 245
G2CC2-30/20 55 700 7000 -20 / +100 253
G3C-30/20 18.5 550 1600 -20 / +100 505
G3CC2-30/20 55 600 7000 -20 / +100 509
TIC-30/28 18.5 800 1600 -20 / +100 138
G2C-30/28 18.5 600 1600 -20 / +100 302
G2CC2-30/28 55 700 7000 -20 / +100 310
G3C-30/28 18.5 400 1600 -20 / +100 577
G3CC2-30/28 55 500 7000 -20 / +100 581

231
Belt Driven Centrifugal Fans / Description

Description

Operating limits RDH


Permissible Permissible Permissible Permissible Fan Permissible Permissible Permissible Permissible Fan
nominal fan speed bearing media weight nominal fan speed bearing media weight
motor load temperature motor load temperature
power power
RDH kW 1/min N C kg RDH kW 1/min N C kg
E0-0180 2.2 6800 420 -20 / +80 5.3 R-0710 15 1300 1800 -20 / +80 165
E2-0180 2.2 6800 420 -20 / +80 7.1 K-0710 22 1500 1900 -20 / +100 220
E0-0200 3 6000 420 -20 / +80 6.6 K1-0710 37 1700 3550 -20 / +100 240
E2-0200 3 6000 420 -20 / +80 8.5 K2-0710 55 2000 5800 -20 / +100 250
E4-0200 3 6800 420 -20 / +100 11.8 G2K-0710 30 1400 3000 -20 / +100 580
E0-0225 4 5800 420 -20 / +80 7.8 G2K2-0710 75 1700 7000 -20 / +100 586
E2-0225 4 5800 420 -20 / +80 9.9 K-0800 22 1200 1900 -20 / +100 270
E4-0225 4 6000 420 -20 / +100 13.6 K1-0800 37 1400 3550 -20 / +100 297
E0-0250 4 4600 420 -20 / +80 13.3 K2-0800 55 1650 5800 -20 / +100 305
E2-0250 4 4600 420 -20 / +80 15.7 G2K-0800 30 1150 3000 -20 / +100 747
E4-0250 5.5 5400 450 -20 / +100 21 G2K2-0800 75 1400 7000 -20 / +100 753
G2E4-0250 5.5 2900 450 -20 / +100 46 K-0900 30 1100 3000 -20 / +100 343
G2E7-0250 7.5 3500 660 -20 / +100 49 K1-0900 45 1250 3900 -20 / +100 355
E0-0280 5.5 4000 530 -20 / +80 17.8 K2-0900 75 1500 7000 -20 / +100 375
E2-0280 5.5 4000 530 -20 / +80 21 G2K-0900 37 1000 3000 -20 / +100 883
E4-0280 7.5 4700 660 -20 / +100 28 G2K2-0900 75 1100 7000 -20 / +100 889
G2E4-0280 5.5 3000 660 -20 / +100 61 K-1000 37 1000 3000 -20 / +100 415
G2E7-0280 11 3400 940 -20 / +100 65 K1-1000 45 1000 3900 -20 / +100 430
E0-0315 5.5 3500 530 -20 / +80 21 K2-1000 75 1300 7000 -20 / +100 450
E2-0315 5.5 3500 530 -20 / +80 25 G2K-1000 37 800 3000 -20 / +100 1048
E4-0315 7.5 4100 660 -20 / +100 32 G2K2-1000 75 800 7000 -20 / +100 1054
E6-0315 11 4500 1050 -20 / +100 34 X1-1120 55 900 8000 -20 / +100 610
G2E4-0315 5.5 2200 660 -20 / +100 70 X2-1120 110 1170 8000 -20 / +100 890
G2E7-0315 11 3300 1320 -20 / +100 79 X1-1250 75 800 8000 -20 / +100 950
E0-0355 7.5 3300 840 -20 / +80 29 X2-1250 132 1050 10000 -20 / +100 1140
E2-0355 7.5 3300 840 -20 / +80 34 X1-1400 90 720 9000 -20 / +100 1370
E4-0355 11 3800 940 -20 / +100 46 X2-1400 160 930 12500 -20 / +100 1390
E6-0355 15 4000 1450 -20 / +100 47
G2E4-0355 7.5 2000 940 -20 / +100 104
G2E7-0355 11 2600 1320 -20 / +100 109
E0-0400 7.5 2700 840 -20 / +80 36
E2-0400 7.5 2700 840 -20 / +80 42
E4-0400 15 3100 940 -20 / +100 57
E6-0400 22 3500 1450 -20 / +100 58
G2E4-0400 7.5 1600 940 -20 / +100 126
G2E7-0400 18.5 2800 1760 -20 / +100 144
E0-0450 11 2500 1180 -20 / +80 50
E2-0450 11 2500 1180 -20 / +80 57
E4-0450 15 2800 1320 -20 / +100 73
E6-0450 30 3200 1800 -20 / +100 75
G2E4-0450 11 1400 1320 -20 / +100 160
G2E7-0450 18.5 2200 1760 -20 / +100 176
E0-0500 11 2100 1180 -20 / +80 62
E2-0500 11 2100 1180 -20 / +80 70
E4-0500 15 2350 1320 -20 / +100 90
E6-0500 30 2650 1800 -20 / +100 92
E7-0500 37 2800 2200 -20 / +100 110
G2E4-0500 11 1200 1320 -20 / +100 197
G2E7-0500 30 2200 3000 -20 / +100 235
E0-0560 15 1950 1450 -20 / +80 79
E2-0560 15 1950 1450 -20 / +80 92
E4-0560 18.5 2100 1760 -20 / +100 141
E6-0560 30 2400 2550 -20 / +100 148
E7-0560 37 2600 3700 -20 / +100 153
G2E4-0560 11 1100 1760 -20 / +100 301
G2E7-0560 30 1900 3000 -20 / +100 336
R-0630 15 1600 1450 -20 / +80 119
K-0630 18.5 1700 1760 -20 / +100 173
K1-0630 30 2000 2550 -20 / +100 180
K2-0630 45 2300 3700 -20 / +100 185
G2K-0630 15 1000 1760 -20 / +100 370
G2K2-0630 37 1400 3000 -20 / +100 408

232
Belt Driven Centrifugal Fans / Description

Description

Operating limits RZR


Permissible Permissible Permissible Permissible Fan Permissible Permissible Permissible Permissible Fan
nominal fan speed bearing media weight nominal fan speed bearing media weight
motor load temperature motor load temperature
power power
RZR kW 1/min N C kg RZR kW 1/min N C kg
11-0200 7.5 7490 480 -20 / +80 11 18-0900 75 1540 6000 -20 / +80 409
12-0200 7.5 7490 480 -20 / +80 12 13-0900 75 1540 6000 -20 / +80 447
19-0200 7.5 7490 480 -20 / +80 13 11-1000 22 800 2200 -20 / +80 416
11-0225 7.5 6640 500 -20 / +80 13 15-1000 75 1140 6200 -20 / +80 416
12-0225 7.5 6640 500 -20 / +80 15 19-1000 75 1140 6200 -20 / +80 462
19-0225 7.5 6640 500 -20 / +80 16 18-1000 75 1400 6200 -20 / +80 471
11-0250 7.5 5250 540 -20 / +80 15 13-1000 75 1400 6200 -20 / +80 517
12-0250 7.5 5250 540 -20 / +80 17 13-1120 132 1220 10000 -20 / +80 710
19-0250 7.5 5970 540 -20 / +80 17 13-1250 160 1100 15000 -20 / +80 1100
11-0280 7.5 5235 630 -20 / +80 20 13-1400 200 1000 20000 -20 / +80 1390
12-0280 7.5 5235 630 -20 / +80 23 13-1600 250 860 20000 -20 / +80 1870
19-0280 11 5300 850 -20 / +80 23
11-0315 7.5 4418 660 -20 / +80 24
12-0315 7.5 4418 660 -20 / +80 27
19-0315 11 4730 910 -20 / +80 28
11-0355 7.5 3200 720 -20 / +80 33
12-0355 7.5 3200 720 -20 / +80 36
19-0355 11 4187 950 -20 / +80 39
11-0400 7.5 3027 1020 -20 / +80 43
12-0400 7.5 3027 1020 -20 / +80 49
15-0400 30 3600 1970 -20 / +80 61
19-0400 30 3600 1970 -20 / +80 66
18-0400 30 3600 1970 -20 / +80 70
13-0400 30 3600 1970 -20 / +80 75
11-0450 7.5 2504 1080 -20 / +80 54
12-0450 7.5 2504 1080 -20 / +80 60
15-0450 30 3360 2000 -20 / +80 73
19-0450 30 3360 2000 -20 / +80 82
18-0450 30 3360 2000 -20 / +80 83
13-0450 30 3360 2000 -20 / +80 92
11-0500 7.5 2050 1140 -20 / +80 65
12-0500 7.5 2050 1140 -20 / +80 72
15-0500 30 2920 2040 -20 / +80 94
19-0500 30 2920 2040 -20 / +80 105
18-0500 30 2920 2040 -20 / +80 105
13-0500 30 2920 2040 -20 / +80 116
11-0560 15 2205 1830 -20 / +80 103
12-0560 15 2205 1830 -20 / +80 109
15-0560 37 2400 2950 -20 / +80 125
19-0560 37 2400 2950 -20 / +80 136
18-0560 37 2490 2950 -20 / +80 140
13-0560 37 2490 2950 -20 / +80 151
11-0630 15 1838 1960 -20 / +80 124
12-0630 15 1838 1960 -20 / +80 132
15-0630 37 1880 3000 -20 / +80 149
19-0630 37 1880 3000 -20 / +80 162
18-0630 37 2380 3000 -20 / +80 167
13-0630 37 2380 3000 -20 / +80 180
11-0710 18.5 1627 2080 -20 / +80 177
12-0710 18.5 1627 2080 -20 / +80 194
15-0710 55 2000 4400 -20 / +80 201
19-0710 55 2000 4400 -20 / +80 225
18-0710 55 2120 4400 -20 / +80 230
13-0710 55 2120 4400 -20 / +80 254
11-0800 22 1300 2150 -20 / +80 250
15-0800 55 1470 4500 -20 / +80 250
19-0800 55 1470 4500 -20 / +80 280
18-0800 55 1700 4500 -20 / +80 289
13-0800 55 1700 4500 -20 / +80 319
11-0900 22 1000 2180 -20 / +80 358
15-0900 75 1430 6000 -20 / +80 358
19-0900 75 1430 6000 -20 / +80 396

233
Belt Driven Centrifugal Fans / Description

Description

Performance
The curves show the total pressure rise pF as a function of the volume flow rate qV
plotted in a double logarithmical diagram. The throttle curves (system resistance
parabolas) are then represented by straight lines.
The curves are established with a reference density of r1 = 1.2kg/m at the fan
intake.
The pressure and impeller input power are directly proportional to density r1.
Outlet velocity v2 and the dynamic pressure pd2 refer to the flanged cross section area
at the fan discharge.

The increase in static pressure psF when a duct is fitted to the discharge (Installation
psF = pF pd2 B) can be calculated from the equation:

Where no duct is fitted (Installation A) there is no static pressure regain. The increase
psF = pF fpd pd2 in pressure psF can be calculated from formula:

The limits of application indicated in the fan curves (by blue dotted lines)
outline the recommended functional range of the fans, where a stable
operation with high efficiency can be expected.

The efficiency marked on the straight system lines is only applicable at the maximum
fan speed Nmax; it decreases with lower fan speed.

ADH RDH RZR


0160/-0560 0630/-1000 0180/-1000 1120/-1400 1120/-1600
fpd 1.9 1.66 1.74 1.15 1.00
RZR 0200/-1000 see fan curves

AT
7/7 9/7 9/9 10/8 10/10 12/9 12/12 15/11 15/15 18/13
fpd 1.96 2.16 1.95 2.08 2.24 1.83 1.94 2.10 2.17 1.98
18/18 20/15 20/20 22/15 22/22 25/20 25/25 28/20 30/20 30/28
fpd 1.86 2.48 2.26 2.46 2.42 2.48 2.49 2.37 2.44 2.41

Efficiency ADH / AT / RDH


Pr The performance curves Pr of the fan curve diagram correspond to the absorbed
a = r
Pr + Pb power of the fan impeller.
The vertical scales shown at the right side of the diagram indicate the bearing power
loss Pb of the different fan executions and depending on the fan speed.
The resulting power absorbed on fan shaft is found by adding the absorbed power Pr
of the fan impeller and the bearing power losses Pb. As a consequence the resulting
fan efficiency is to be calculated according to the formula:

Efficiency RZR
The actual efficiency value for a fan speed lower Nmax is calculated by multiplying the
efficiency at Nmax by the factor fh for the appropriate speed. (fh to be found with the
scale on the right side of the page).

Motor nominal power ADH / AT / RDH / RZR


PN Pa fP To determine the motor rating PN, the fan absorbed shaft power Pr must be increased
by a safety factor to accommodate belt drive losses and possible fan speed
differences.
The factor fp is an estimated value. As an approximate value, the figures below are
suggested.

ADH / AT RDH / RZR


Pa < 0.75 kW fp = 1.30 Pa < 0.75 kW fp = 1.25
Pa 0.75 kW ... < 10kW fp = 1.20 Pa 0.75 kW ... < 10 kW fp = 1.15
Pa 10 kW fp = 1.15 Pa 10 kW fp = 1.12

234
Belt Driven Centrifugal Fans / Description

Description

Performance
When selecting the motor, the run up time must be checked whether being within
8 J N permitted limits.
tA =
PN 106 The run up time can be worked out approximately according to the following formula:
where:
tA = run time in seconds
J = moment of inertia in kgm
N = fan speed in rpm
PN = nominal motor power in kW
(Impeller weight and moment of inertia can be found on the performance diagram for
each fan size.)

If tA exceeds the motor manufacturers recommendation or the tripping period of the


electrical gear, a larger motor must be used or the starting gear has to be selected for
heavy starting.

Fan curves measurement ADH / AT / RDH - AMCA 210-99 / ISO5801


1 = Test fan 1 2 3 4 5
2 = Discharge duct
3 = Screen
4 = Multiple nozzles
5 = Auxiliary fan and damper

pe4 pe6 p

Fan curves measurement RZR - ISO5801 / DIN24163


1 = Test fan 2 1 3 4 5 6 7
2 = Discharge duct acting as a pressure regain unit
3 = Screen
4 = Variable damper
5 = Compensating fan
6 = Flow straightener
7 = Inlet cone

t1
pa ta psF qV = f(po) po

Performance data of twin fan units


The performance data of twin fan units (Identification "G2") can be calculated, starting
from that in the corresponding operating point of a single fan, with the following
formulas:

A Fan Pressure: pF G2 = pF 1
A Volume flow rate: qV G2 = qV 2
A Fan shaft power: Pa G2 = Pa 2,15
A Rotational speed: N G2 = N 1,05
A Sound: LWA G2 = LWA + 3dB

AMCA
NicotraGebhardt S.p.A. (Italy) certifies that
ADHE fans of the E0, E2, E4, E6 and E7 versions, from sizes 0160 to 0560,
RDHE fans of the E0, E2, E4, E6 and E7 versions, from sizes 0180 to 0560,
ADH and RDH fans of the L, R, K, K1 and K2 versions, from sizes 0630 to 1000,
AT fans of the S, SC, C and TIC versions, from sizes 7/7 to 30/28,
shown herein are licensed to bear the AMCA Seal.
NicotraGebhardt GmbH (Germany) certifies that RZR fans of the 11, 12, 15 versions,
from sizes 0355 to 1000, shown herein are licensed to bear the AMCA Seal.
The ratings shown are based on tests and procedures performed in accordance
with AMCA Publication 211 and comply with the requirements of the AMCA Certified
Ratings Program.
Air performance with Installation Type A (with free outlet), and that of the twin fan
versions G2L, G2R, G2K, G2K2, G2E0, G2E2, G2E4, G2E7, SC2, G2C and G2C-C2,
and that of the triple fan versions G3C and G3C-C2 in any installation type is not
AMCA licensed.

235
Belt Driven Centrifugal Fans / Description

Description

Sound
Noise measurements are undertaken in accordance with DIN45635-38 Noise
Measurement of Machines: Fans.

Induct Method for the Discharge


The induct method is specified with DINENISO5136. It determines the sound power
emitted at discharge of a test fan.
The test duct, as a main feature, is equipped with an anechoic termination fitted to
avoid end reflection going back into the duct.

Envelope Method Free Inlet


The Envelope Method is described with DIN45635-1 and -38, which specifies a
hypothetical box shaped measurement surface with several prescribed measurement
points.

1 = Air permeable sound screen 1 2 3 4 5 6 7


2 = Microphone positions for envelope method
3 = Test fan
4 = Measuring duct
5 = Microphone with sampling tube
6 = Anechoic termination
7 = Step less adjustable throttle
Lp4

Lp7

psF

The sound data of the fan curves are given as A weighted sound power levels.

A-sound power level RZR


The A weighted sound power level are identical for fan intake (LWA7) as well as for
fan discharge (LWA4).

A-sound power level ADH / AT / RDH


LWA4 = LWA7 + LWrel4(A) The A weighted sound power level (see curves) are apply for fan intake (LWA7). The
fan discharge sound power level LWA4 is obtained by calculating:
The correction value DLWrel4(A) is found with the table (left below) at the corresponding
fan curve page (ADH / RDH) by introducing fan speed and flow rate.

An approximation of the A weighted sound pressure levels LpA7/LpA6 at a distance


of 1 m may be obtained by subtracting 7dB from the relative A weighted sound
power levels.
If should be noted that site acoustics, duct design, reverberation, natural frequencies
etc. can all influence noise to a greater or lesser extent.
For more accurate calculations to determine noise protection measures, the sound
ADH / AT / RDH: RZR: power level in each octave band is of more value:
LWfc7 = LWA7 + LWrel7 LWfc7 = LWA4;7 + LWrel7
LWfc4 = LWA7 + LWrel4 LWfc4 = LWA4;7 + LWrel4

The noise correction data LWrel4 und LWrel7, in function of the fan speed and flow rate,
are to be found with the corresponding table on the fan curve page.
In some cases the noise level - calculated by this way - may in some cases be higher
than expected at the blade passing frequency.

fs = Blade passing frequency in Hz


Nz N = Fan speed in 1/min
fBP =
60 z = No of blades (see curve pages)

236
Belt Driven Centrifugal Fans / Description

Description

Sound
For a free discharge situation i.e. without duct connected the sound level will be lower
LWfc6 = LWfc4 + LWer because of an end reflection.
This is specially true for low frequencies. For this case a correction may be applied to
LWfc4 of the first 3 octave bands as follows:

ADH / AT / RDH / RZR fc 63 125 250 Hz


0160/-0280 LWer -14 -9 -4 dB
0315/-0800 LWer -9 -4 -2 dB
0900/-1600 LWer -4 -1 0 dB

Explosion protection according to ATEX


Fans for use in explosive atmospheres must comply with EC Directive 94/9/EG
(ATEX 95). Equipment in Group II (all applications except mining) is categorised in
accordance with the required degree of safety for designated use in equipment
categories 1, 2 and 3. Depending on suitability, a distinction is in addition made
between G (gas, vapours) and D (dust).
Harmonised European standards and national guidelines must be observed.
Equipment in class 2 and 3 is not subject to compulsory specifications nor to type
testing. The manufacturer declares conformity with the EC directive.

For the standard designs of our fans, the following ignition sources are
essentially to be considered:
A Hot surfaces, e.g. due to heat of friction or seizure of a bearing or due to blockage
of an impeller
A Rubbing-, grinding- or beating sparks, e.g. as a result of contact of the impeller with
stationary components
A Sparks resulting from discharge of electrostatically loaded, non-conducting
omponents, e.g. of plasticpanels, surfaces with strong layer thickness.

Preconditions for operating:


A In the proximity of the motor, the temperature limits -20C and +40C must
not be exceeded.
A The temperature limits of -20C und +60C for the flow medium must not
be exceeded. If the temperature of the flow medium should exceed +60C
on the pressure side, then the fan must be switched off!
A The fans may only be employed with a horizontal shaft.
A The fans are to be protected against the falling-in or sucking-in of foreign
objects. Protection guards must be ordered separately as an accessories.
A On the machine plate the max. permitted fan speed is indicated.
A Fans for operation in ex-hazardous areas are marked as such on the
machine plate and they are accompanied by an EU conformity declaration
and with operation and maintenance instructions.

The operation and maintenance instructions have strictly to be observed.

The conformity is always related to the fan system supplied.


If the fan is completed with motor and belt drive by the customer the conformity of
this fan set has to be declared at new.

Fans of the series ADH / AT / RDH in ATEX-Execution on request.

237
Belt Driven Centrifugal Fans / Description

Description

Operating limits RZR ATEX


Permissible fan speed Permissible shaft power Permissible nominal
motor power
RZR 1/min kW kW
11-0200-2G 6513 4.7 5.5
12-0200-2G 6513 4.7 5.5
19-0200-2G 6513 4.7 5.5
11-0225-2G 5774 4.7 5.5
12-0225-2G 5774 4.7 5.5
19-0225-2G 5774 4.7 5.5
11-0250-2G 4620 4.7 5.5
12-0250-2G 4620 4.7 5.5
19-0250-2G 5076 4.7 5.5
11-0280-2G 4582 6.5 7.5
12-0280-2G 4582 6.5 7.5
19-0280-2G 4582 9.7 11
11-0315-2G 3793 6.5 7.5
12-0315-2G 3793 6.5 7.5
19-0315-2G 4113 9.7 11
11-0355-2G 3110 6.5 7.5
12-0355-2G 3110 6.5 7.5
19-0355-2G 3555 9.7 11
11-0400-2G 2552 6.5 7.5
12-0400-2G 2552 6.5 7.5
13-0400-2G 3145 16.4 18.5
18-0400-2G 2913 9.7 11
11-0450-2G 2111 6.5 7.5
12-0450-2G 2111 6.5 7.5
13-0450-2G 2922 21.3 24
18-0450-2G 2410 9.7 11
11-0500-2G 1752 6.5 7.5
12-0500-2G 1752 6.5 7.5
13-0500-2G 2534 21.3 24
18-0500-2G 2000 9.7 11
11-0560-2G 1660 9.7 11
12-0560-2G 1660 9.7 11
13-0560-2G 2163 26.6 30
18-0560-2G 1660 9.7 11
11-0630-2G 1367 9.7 11
12-0630-2G 1367 9.7 11
13-0630-2G 2055 32.8 37
18-0630-2G 1367 9.7 11
11-0710-2G 1128 9.7 11
12-0710-2G 1128 9.7 11
13-0710-2G 1825 40.9 45
18-0710-2G 1128 9.7 11
11-0800-2G 927 9.7 11
18-0800-2G 927 9.7 11
13-0800-2G 1474 40.9 45
11-0900-2G 767 9.7 11
18-0900-2G 767 9.7 11
13-0900-2G 1339 68 75
11-0100-2G 650 9.7 11
18-1000-2G 650 9.7 11
13-1000-2G 1217 68 75
13-1120-2G 1026 83.6 92
13-1250-2G 957 122 135
13-1400-2G 870 145 160
13-1600-2G 748 181 200

238
Belt Driven Centrifugal Fans / Description

Description

Symbol / Unit / Definition

The following symbols are used in this catalogue: The following symbols are used in this catalogue:

A-A - Operational range (free discharge) PN kW Motor power (nominal)

A2 mm Fan outlet area psF Pa Fan static pressure (free discharge)

b mm Deflection of belt under test force gp Pa Differential pressure

Dr mm Impeller diameter gp0 Pa Pressure difference at the inlet measuring device

fBP Hz Blade passing frequency gpD Pa Pressure difference at the inlet cone

fc Hz Octave centre frequency qv m/h Volume flow rate

fp - Motor size correction factor qVopt m/h Volume flow at optimum efficiency

Fp N Test force RW J/kgK Specific gas constant

fpd - Dynamic pressure correction factor (free discharge) t C Temperature of flow medium

fh - Correction at actual efficiency ta C Temperature of discharge air in test chamber

J kgm Moment of inertia tA s Acceleration time

K ms/h Calibration factor for volumeter t1 C Air temperature

LT mm Centre distance K Thermodynamic temperature at fan inlet

LMg mm Measuring marks before tensioning (flat belts) u m/s Tip speed

LMu mm Measuring marks after tensioning (flat belts) v2 m/s Outlet velocity

LpA4 dB A weighted sound pressure level (discharge) vm2 m/s Average fluid velocity at discharge

LpA7 dB A weighted sound pressure level (inlet) X mm Pulley position on shaft extension relative to bearing

LWA dB A weighted sound power level z - No. of blades

LWA4 dB In duct sound power level (discharge) e* mm Stretching value of flat belt

LWA7 dB Casing and free inlet sound power level ha % Total efficiency at max speed

LWfc4 dB Discharge sound power in the octave bands hr % Impeller efficiency

LWfc7 dB Inlet sound power in the octave band hs % Fan total efficiency at max speed

LWrel4 dB Relative sound power (discharge) r kg/m Air density

LWrel7 dB Relative sound Power (inlet) r1 kg/m Air density at fan inlet

L10h h Nominal bearing life

m kg Mass

N 1/min Fan speed

Nmax 1/min Maximum fan speed

pa Pa Atmospheric pressure

Pa kW Absorbed fan power

Pb kW Bearing power losses

pd2 Pa fan dynamic pressure at discharge

pF Pa Total fan pressure

239
Belt Driven Centrifugal Fans / Description / Notes

Notes

Quality management system


DINENISO9001
NicotraGebhardt quality is the result of a continuous company policy intended to
guarantee that our product properties and features are clearly superior to comparable
products.
This already established company maxim led in April 1985 to the auditing and
certification of the existing quality management system. In the following years it was
updated to match the changing international and European standards. Modern
production processes, monitored by our quality management system, guarantee a
high repeat accuracy in production.
This ongoing high standard of quality permits the establishing of the performance
data in classes of accuracy in accordance with DIN24166.
The narrow tolerances ensure a high level of data reliability for our products.

Machine Safety
The fans contained in this catalogue are not machines in the sense of the EC Machine
Directive. They are delivered with a manufacturer "Declaration of incorporation".
The assessment of the dangers associated with the fan and necessary safety
measures are based on the VDMA Unit sheet 24167: Fans; Safety requirements.
The operating instructions give which safety measures are still necessary on assembly
to ensure that the fans comply with the Machine Directive 2006/42/EC.

Catalogue data
We reserve the right to change any measurements and technical data in this
catalogue in accordance with further development of our products. All information
valid at the time of printing.

240
Nicotra Gebhardt worldwide

EN-TD3-CFB-2.5 PDF1-August2013
AUSTRALIA
65 Yale Drive, nicotra-gebhardt.com
Epping, VIC 3076
Phone +61 3 9017 5333
Fax +61 3 8401 3969
E-mail info@nicotra.com.au

BELGIUM
Haeghensgoed, 13 - 00/01
9270 Laarne
Phone +32 (0)9-336-00-01
Fax +32 (0)9-336-00-05
E-mail info.nicotra@nicotra.be

CHINA
88 TaiAn Road, XinQiao, ShiJi, Panyu
Guangzhou 511450
PR CHINA
Phone +86 (0)20-2293 5700
Fax +86 (0)20-2293 5701
E-mail sales@nicotra-china.com

FRANCE
Leader's Park Bat A1
3 chemin des Cytises
69340 Francheville
Phone +33 (0)4 72 79 01 20
Fax +33 (0)4 72 79 01 21
E-mail g.cauche@nicotra-gebhardt.com

GERMANY
Gebhardtstrae 19-25
74638 Waldenburg
Phone +49 (0)7942 101 0
Fax +49 (0)7942 101 170
E-mail info@nicotra-gebhardt.com

GREAT BRITAIN MALAYSIA SWEDEN


Unit D, Rail Mill Way Lot 1799, Jalan Balakong Kraketorpsgatan 30
Parkgate Business Park Taman Perindustrian Bukit Belimbing 43153 Mlndal
Rotherham 43300 Seri Kembangan Phone 0046 101-302600
South Yorkshire Selangor Fax 0046 31-878590
S62 6JQ Phone +603 8961-2588 E-mail info.se@nicotra-gebhardt.com
Phone +044 01709-780760 Fax +603 8961-8337
Fax +044 01709-780762 E-mail info_malaysia@nicotra-gebhardt.com THAILAND
E-mail sales@nicotra.co.uk 6/29 Soi Suksawadi 2, Moo 4, Suksawadi Road,
SPAIN Kwang Jomthong, Khet Jomthong,
INDIA Ctra. Alcal-Villar del Olmo, Km. 2,830 Bangkok 10150
Plot no 28F & 29, Sector-31,Kasna, 28810 Villalbilla-Madrid Phone +662 476-1823-6
Greater Noida-201 308 U.P (India) Phone +34 918-846110 Fax +662 476-1827
Phone +91 120 4783400 Fax +34 918-859450 E-mail sales@nicotra.co.th
Phone +91 22 65702056 (Mumbai) E-mail info@nicotra.es
Phone +91 80 25727830 (Bangalore) UNITED STATES
E-mail info@nicotraindia.com SINGAPORE PO BOX 900921
3, Science Park Drive, # 04-07, The Franklin Sandy, Utah 84090
ITALY Singapore Science Park 1 Phone 001(801) 733-0248
Via Modena, 18 Singapore 118223 Fax 001(801) 315-9400
24040 Zingonia (BG) Phone +65 6265 1522 Mobile 001(801) 682 0898
Phone +39 035 873 111 Fax +65 6265 2400 E-mail mike.sehgal@gebhardtfans.com
Fax +39 035 884 319 E-mail info_singapore@nicotra-gebhardt.com http://www.gebhardtfans.com/
E-mail info@nicotra-gebhardt.com

Nicotra Gebhardt Germany Nicotra Gebhardt Italy

Nicotra Gebhardt GmbH Nicotra Gebhardt S.p.A


Gebhardtstrae 19-25 Via Modena, 18
74638 Waldenburg 24040 Zingonia (BG)
Germany Italy
Phone +49 (0)7942 101 0 Phone +39 035 873 111
Fax +49 (0)7942 101 170 Fax +39 035 884 319
E-Mail info@nicotra-gebhardt.com E-Mail info@nicotra-gebhardt.com nicotra-gebhardt.com
241