Escolar Documentos
Profissional Documentos
Cultura Documentos
SPECIFICATIONS
Contact Characteristics
Arrangement 1 Form C2 (H bridge) Max. operating speed
6 cpm
Contact material Silver alloy (at rated load)
Initial contact resistance, max. Initial insulation resistance*1 Min. 100 m (at 500 V DC)
50 m
(By voltage drop 6 V DC 1 A) Between open
1,000 Vrms for 1 min.
Contact voltage drop, max. 0.2 V (at 20 A switching) Initial breakdown contacts
voltage*2 Between
Nominal switching N.O.: 20A 14 V DC 1,000 Vrms for 1 min.
capacity N.C.: 10A 14 V DC contacts and coil
Max. switching power 140 W Operate time* 3
Max. 10 ms
(at nominal voltage)
Max. switching voltage 16 V DC
Rating Release time (without diode)*3
10 A (Continuous), Max. 10 ms
(at nominal voltage)
Max. make current 30 A (within 1 min.; coil applied
voltage: 12 V, at 20C) Functional*4 Min. 100 m/s2 {10 G}
Shock resistance
30 A (2 minutes ), 20A (1 hour) Destructive*5 Min. 1,000 m/s2 {100 G}
Max. carrying current
(coil applied voltage: 12 V, at 20C) Approx. 44.1 m/s2 {4.5 G},
Functional*6
Mechanical (at 180 cpm) 106 Vibration 10 to 100 Hz
resistance Approx. 44.1 m/s2 {4.5 G},
resistive load Min.105 Destructive
Expect 10 to 500 Hz
ed life 7 A 14 V DC,
Inrush 30 A 2105 Conditions for 40C to + 85C
(min. Ambient temp.
Electrical
(Motor load) operation, trans- 40F to +185F
ope.) port and storage*7
20 A 14 V DC
Min.5104 (Not freezing and
(Motor lock) condensing at low Humidity 5 to 85%R.H.
Coil temperature)
Unit weight Standard type Approx. 15 g .529 oz
Nominal operating power 640 mW
Remarks
* Specifications will vary with foreigh standards certification ratings. *5 Half-wave pulse of sine wave: 6ms
*1 Measurement at same location as "Intial breakdown voltage" section *6 Detection time: 10s
*2 Detection current: 10mA *7 Refer to 5. Conditions for operation, transport and storage mentioned in
*3 Excluding contact bounce time AMBIENT ENVIRONMENT (Page 61)
*4 Half-wave pulse of sine wave: 11ms; detection time: 10s
367
CF
TYPES AND COIL DATA (at 20C 68F)
Nominal
Drop-out Nominal Usable voltage
Nominal voltage, Pick-up voltage, Coil resistance, operating
Part No. voltage, operating Power, range,
V DC V DC (max.) (10%) current,
V DC (min.) mW VDC
mA (10%)
CF2-12V 12 7.2 1.0 225 53.3 640 10 to 16
DIMENSIONS mm inch
EXAMPLE OF CIRCUITS
Forward/reverse control circuits of DC motor for power window
N.O. N.O.
COM COM
12 V DC M
N.C. N.C.
SW A SW B Motor
OFF OFF Stop
SW A SW B ON OFF Forward
OFF ON Reverse
M : Power window motor
368
CF
REFERENCE DATA
1-(1). Coil temperature rise (at 23C 73F) 1-(2). Coil temperature rise (at 85C 185F) 2-(1). Electrical life test (Motor lock)
Tested sample: CF2-12V, 6pcs. Tested sample: CF2-12V, 6pcs. Tested sample: CF2-12V, 3pcs.
Contact carrying current: 0A, 7A, 10A, 15A, 20A Contact carrying current: 10A, 15A, 20A Load: 20A 14V DC
Operating frequency: ON 1s, OFF 5s
100 10
100 Contact welding: 0 times
20 A Miscontact: 0 times
Temperature rise, C
20A
Temperature rise, C
80 15 A
70 10 A 15A Pick-up voltage
7A Max.
0A 60 6
60 10A X
50 Min.
40 40 4
30 Drop-out voltage
Max.
20 20 2 X
Min.
10
0
12 14 16 0 0
12 14 16 0 5
Coil applied voltage, V
Coil applied voltage, V No. of operations, 104
Sample 8
Pick-up voltage
Max.
6
X
Min.
M
4
Drop-out voltage
Max.
2 X
Min.
0
0 10 20
No. of operations, 104
For Cautions for use, see Relay Technical Information (Page 48 to 76).