Você está na página 1de 3

CF

NEW DUAL POWER


AUTOMOTIVE RELAY CF-RELAYS
22.5
.886 16.5
.650
FEATURES Normally Normally
Open Closed
7 Amp Steady/30 Amp Inrush current
16.5 capability
.650
Simple footprint enables ease of PC
board layout Coil 1
Common
Open
Space Coil 2
mm inch

SPECIFICATIONS
Contact Characteristics
Arrangement 1 Form C2 (H bridge) Max. operating speed
6 cpm
Contact material Silver alloy (at rated load)
Initial contact resistance, max. Initial insulation resistance*1 Min. 100 m (at 500 V DC)
50 m
(By voltage drop 6 V DC 1 A) Between open
1,000 Vrms for 1 min.
Contact voltage drop, max. 0.2 V (at 20 A switching) Initial breakdown contacts
voltage*2 Between
Nominal switching N.O.: 20A 14 V DC 1,000 Vrms for 1 min.
capacity N.C.: 10A 14 V DC contacts and coil
Max. switching power 140 W Operate time* 3
Max. 10 ms
(at nominal voltage)
Max. switching voltage 16 V DC
Rating Release time (without diode)*3
10 A (Continuous), Max. 10 ms
(at nominal voltage)
Max. make current 30 A (within 1 min.; coil applied
voltage: 12 V, at 20C) Functional*4 Min. 100 m/s2 {10 G}
Shock resistance
30 A (2 minutes ), 20A (1 hour) Destructive*5 Min. 1,000 m/s2 {100 G}
Max. carrying current
(coil applied voltage: 12 V, at 20C) Approx. 44.1 m/s2 {4.5 G},
Functional*6
Mechanical (at 180 cpm) 106 Vibration 10 to 100 Hz
resistance Approx. 44.1 m/s2 {4.5 G},
resistive load Min.105 Destructive
Expect 10 to 500 Hz
ed life 7 A 14 V DC,
Inrush 30 A 2105 Conditions for 40C to + 85C
(min. Ambient temp.
Electrical
(Motor load) operation, trans- 40F to +185F
ope.) port and storage*7
20 A 14 V DC
Min.5104 (Not freezing and
(Motor lock) condensing at low Humidity 5 to 85%R.H.
Coil temperature)
Unit weight Standard type Approx. 15 g .529 oz
Nominal operating power 640 mW
Remarks
* Specifications will vary with foreigh standards certification ratings. *5 Half-wave pulse of sine wave: 6ms
*1 Measurement at same location as "Intial breakdown voltage" section *6 Detection time: 10s
*2 Detection current: 10mA *7 Refer to 5. Conditions for operation, transport and storage mentioned in
*3 Excluding contact bounce time AMBIENT ENVIRONMENT (Page 61)
*4 Half-wave pulse of sine wave: 11ms; detection time: 10s

TYPICAL APPLICATIONS ORDERING INFORMATION


Automotive: Power-window, power sunroof, etc.
Ex. CF 2 12 V

Contact arrangement Coil voltage(DC)


1 Form C 2 12 V
Standard packing: Carton: 35pcs.; Case: 700pcs.

367
CF
TYPES AND COIL DATA (at 20C 68F)
Nominal
Drop-out Nominal Usable voltage
Nominal voltage, Pick-up voltage, Coil resistance, operating
Part No. voltage, operating Power, range,
V DC V DC (max.) (10%) current,
V DC (min.) mW VDC
mA (10%)
CF2-12V 12 7.2 1.0 225 53.3 640 10 to 16

DIMENSIONS mm inch

Recommended PC board pattern


16.5 (6-4 dia.)
.650 (6-.157 dia.) Land diameter (R1.5)
1.2 max. 1.270.1
.047 max. .050.004
5.080.1
3.5 12.70.1 .200.004
.138 .500.004 2.540.1
0.3 0.3 .100.004
6.350.1 (0.8) (3) 5.080.1
.012 .012 .250.004
0.3 1.1 (.031) (.118) .200.004
.012 .043
1 8-1.5 dia.0.1 3.810.1
.039 8-.059 dia..004 .150.004

5.08 7.620.1 10.160.1


12.7 .200 .300.004 .400.004
.500 2.54
16.5 .100
.650 5.08
.200 Schematic
3.81
.150 N.O.
1.1 1.1 7.62 10.16 COM1
.043 .043 .300 .400
0.4 22.5
.886 N.C.
.016 0.4
.016 COM2
1.1
.043

Dimension: General tolerance


Max. 1mm .039 inch: 0.1 .004
1 to 3mm .039 to .118 inch: 0.2 .008
Min. 3mm .118 inch: 0.3 .012

EXAMPLE OF CIRCUITS
Forward/reverse control circuits of DC motor for power window

N.O. N.O.
COM COM
12 V DC M
N.C. N.C.
SW A SW B Motor
OFF OFF Stop
SW A SW B ON OFF Forward
OFF ON Reverse
M : Power window motor

368
CF
REFERENCE DATA
1-(1). Coil temperature rise (at 23C 73F) 1-(2). Coil temperature rise (at 85C 185F) 2-(1). Electrical life test (Motor lock)
Tested sample: CF2-12V, 6pcs. Tested sample: CF2-12V, 6pcs. Tested sample: CF2-12V, 3pcs.
Contact carrying current: 0A, 7A, 10A, 15A, 20A Contact carrying current: 10A, 15A, 20A Load: 20A 14V DC
Operating frequency: ON 1s, OFF 5s

100 10
100 Contact welding: 0 times
20 A Miscontact: 0 times

Pick-up and drop-out voltage, V


90
80 8

Temperature rise, C
20A
Temperature rise, C

80 15 A
70 10 A 15A Pick-up voltage
7A Max.
0A 60 6
60 10A X
50 Min.

40 40 4

30 Drop-out voltage
Max.
20 20 2 X
Min.
10
0
12 14 16 0 0
12 14 16 0 5
Coil applied voltage, V
Coil applied voltage, V No. of operations, 104

2-(2). Electrical life test (Motor free)


Tested sample: CF2-12V, 3pcs.
10
Load: 7A steady, Inrush 30A, 14V DC Contact welding: 0 times
Operating frequency: ON 1s, OFF 5s Miscontact: 0 times
Pick-up and drop-out voltage, V

Sample 8

Pick-up voltage
Max.
6
X
Min.
M
4

Drop-out voltage
Max.
2 X
Min.

0
0 10 20
No. of operations, 104

For Cautions for use, see Relay Technical Information (Page 48 to 76).

9/1/2000 All Rights Reserved, Copyright Matsushita Electric Works, 369


Ltd.
Go To Online Catalog