Você está na página 1de 2

175 WATT IVERCURY VAPOR

M3111

1. Medium base socket B.Adjuslable plaster ring is


2. Extruded aluminum heat sink mounted to frame to aJlow
for heat dissipation 11 adjustment according to
ceiling depth up to 1" trom
3. Vent holes
below the ceiling
4. B"low brightness black ballle 9. Baftle and housing held with
and housing tension springs-2 ways
5. 175W. R40
10- Die formed frame is
6. Ballast and splice box conslructed of 16 GA.
assemblV CWA HPF accessible galvanized steel
from below the ceiling 11. 2-27" long mounting bars
7. Double-faced junction box 12. Slotted adjustment for
mounting bars

Design Housing Recessed Trim Type of


Number Dimensions width Length Height Dimensions Lamp

175W
M3t 11 8%" Diam. 23Ya" 11Yr" Bsls" Diam.
R40 Coated

Specily Voltage Required Baflle is linished in 3M Nextel Black

SPECIFICATIONS
Low brightness downlight utilizes a sharply defined allow a maximum of 1" of movement to compensate
groove in a round 8" baffle with a long life coated for ceiling construction. Frame is furnished with
mercury "R" lamp provides a widespread distribution double-faced junction box and is completely pre-
of light with minimum brightness. Balfle and housing wired.
maintained in unit by two tension springs to assure Fixture is wired wilh 200" C. SF2 Silicone wire and
ease of lnstallation. nickel-plated screw shell socket. Aluminum conduit
Encased and potted constant waltage autolrans- allows lolal Ilexibility. Porcelain socket is housed in
former ballast carries a "B" sound rating on a scale pure aluminum heat sink for effective heat dissipation.
ol "A" thru "F", and is guaranteed lor two years of Labels
normal service with free replacement and installa-
tion if due to faulty workmanship or material. Ballast Underwriters listed, damp location, through branch
is completely accessible Jrom below ceiljng line and circ u it wiring, l.B.E.W.
can be mounted remote if desired. Note
The 16 GA. galvanized steel strength frame is Fixture is shipped fully assembled and pre-wired.
lurnished tor installation with two 10 GA.27" long Baffle and Housing separately protected to prevent
mounting bars. Cut-outs on end ol frame allows {or damage during installation and ljnishing of ceiling.
complete flexibllity of mounting bars or lathing Keyhole slotted top allows ease of installation to
channel (by others). lnner plaster ring is slotted to heat sin k.
M
29
O COPYRIGHT OCT. 1 975, N L CORPORATION . 14901 BFOADWAY, CLEVELAND, OHIO 44137
Certified Test Report No. EBL 1393
NL Corp. Recessed oownlight, Cat. No.3111
One GE Hl75RFL39-22 175w Reflector Mercury Lamp,
Rated 5700 Lumens

Average Luminance Dala Luminance Summary-Footlamberts


Footlamberts Angle Average FL
Angle Luminance 45 3097
0 39205 50 1627
30 16135 55 790
40 5499 60 274 Total Lumens
45 3097 65 170
Zone Lumens Percent
50 1627 70 0
0-40 2657 46.62
55 790 75 0
0-60 2a92
60 278 BO 0
0-90 2899
50.75
65 170 85 0 50.87
1000 70 0
75 0
I500 BO
B5 I C"nitied Test Report No. EBL 1392
2AOA " NL Corp. Recessed Downlight. Cat. No.3t0t
One GE H100RFL38-4 100W R40 Mercury Lamp, Rated 2850 Lumens
2500
Coetf icients Ol ulilization
3000 Effective Floor Cavity Refleclance .20 :
3500 cc 80 70 50 30 10 0
4000
Wall 70 50 30 '10 70 50 30 10 50 30 t0 50 30 10 50 30 10 0
RCR
4500 1 .58 .57 .56 .55 .57 .56 .54 .54 .53 .52 .52 .51 .51 .50 .50
.55 .49 .48
5000
2 .56 .54 .52 .51 .55 .53 .s0 .51 .s0 .49 .50 .49 .48 .49 .48
.51 .47 .46
3 .s4 .51 .49 .47 .53 .50 .47 .49 .47 .46 .4a .47 .45 .47 .46
.48 .45 .44
5500 4 .52 .48 .46 .44 .51 .48 .44 .47 .45 .44 .46 .44 .43 .45 .44
.46 .43 .42
5 .49 .46 .43 .42 .49 .45 .43 .41 .45 .43 .41 .44 .42 .41 .43 .42 .40 .40
6 .48 .44 .41 .40 .47 .43 .41 .39 .43 .41 .39 .42 .40 .39 .41 .40 .39 .38
7 .45 .42 .39 .37 .45 .41 .39 .37 .41 .38 .37 .40 .38 .37 .40 .38 .36 .36
8 .44 .39 .37 .35 .43 .39 .37 .3s .39 .36 .35 .38 .36 .35 .38 .36 .35 .34
S/MH :
,8 I .42 .38 .35 .33 .41 .37 .35 .s3 .37 .35 .33 .36 .34 .33 .36 .34 .33 .32
MED- SPBEAD 10 .40 .36.33.31 .3S.35.33.31 .35 .33 .31 .35 .33 .31 .s4 .32 .31 .30

Suitable for '175W. 840 Lamp without f actor

Number ol Luminaires Required for 30.0 and 70.0 FC. Candlepower Dala Candlepower Summary
Light Loss Factor : .75 See Foolnote Angle Candlepower Lumens Angle Average CP
-
CC, Wall + FC Reflectances: 80, 50, 20 0 3961 0 3961
work Plane Height: 2.5 Feet 5 3857 365 5
'10
3Bs7
10 3610 3610
Room 30.0 Foolcandles 70,0 Footcandles 15 3116 467 15 3116
Dimensions tleight Height 20 2394 20 2394
8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 25 1891 a7a 25 1891
20 20 5667 13 13 14 15 30 1412 30 1412
20 30 8899 19 19 21 22 35 825 548 35 825
20 40 11 11 12 12 25 25 27 28 40 426 40 426
20 60 16 16 17 1B 36 37 39 41 45 220 1BB 45 220
106
30 20 8899 19 1S 21 22 50 106
47
50
s
30 30 12 12
'15 16
13 13 27 2A 30 31 55 46 55
60 14
30 40 17 17 36 37 39 40 60 14
7
30 60 23 23 24 25 53 54 56 59 65 7 7 65
30 80 30 31 32 33 70 72 74 77 10
75
0
0 0
70
75
0
0
40 20 11 11 12 12 25 25 27 28 80 0 80 0
40 30 15 16 17 17 36 37 39 40 B5 0 0 85 0
40 40 20 21 22 22 47 4A 50 52 90 0
40 60 30 30 31 33 70 71 73 76
40 80 40 40 41 43 92 94 97 100 Total Output
40 100 49 50 51 53 115 117 120 124 Zone Lumens Percent
60 30 23 23 24 25 53 54 56 59 0-40 2657 46.62
60 40 30 30 31 33 70 71 73 76 0,60 2892 50.75
60 60 44 45 46 47 103 105 108 111 o-70 2899 50.87
60 B0 60 59 61 62 140 138 142 145 0-90 2899 50.87
60 100 75 74 75 77 176 172 176 180 40-90 242 4.26
100 40 49 50 51 53 115 117 120 124 60-90 7 .12
100 60 75 74 75 77 176 172 176 180 70-90 0 0.00
100 B0 102 100 99 101 238 233 232 236 90-180 0 0.00
100 100 12A 126 123 125 @0 295 288 292 0-180 2899 50.87

For other light loss faciors: Tested in Accordance with IES procedLlres.
No. of luminaires required: No. from table X.75lNew LLF Test distance exceeds 25 feet.
M
30
ac) coPYRlcHr OcT.1s75, NL CORPORATION . 14901 BEoADWAY, cLEVELAND, oHlo 44137

Você também pode gostar