Escolar Documentos
Profissional Documentos
Cultura Documentos
Working Scope
Payment Terms:
Validity
Remark
Rectification charges for Form tie Area = 58,000 kyats per 1 Sq-m
Working Scope
Payment Terms:
Validity
Remark
S B R L at e x f o r Wat e r p r o o f i n g & R e pa i r s
Description
Dr. Fixit Super Latex is based on modified Styrene butadiene latex used for high performance applications in
waterproofing and repairs. It is used for repairs of spalled concrete such as floors, columns, beams, chhajjas,
slabs & waterproofing of toilets & bathrooms & terraces. It bonds strongly to old & new concrete & plaster.
302 Dr. Fixit Super Latex
Areas of Application
}} s a bond coat - Plaster to plaster, concrete-to-concrete, plaster to concrete masonry to stone work and for
A
plastering over brick masonry. Bonding coat & mortar for tiles & panels, underlays for special finishes such as
top rendering coat for chemical resistant floors.
}}As waterproofing Waterproofing of small roof terraces, sunken portions of toilet & bathrooms, chajjas & lift
pits, balconies & stare cases. waterproofing of liquid & effluent tanks, car deck and walk ways.
}}As crack repair - Repairs of plaster cracks more than 5 mm & in gaps developed between masonry and RCC
members.
}}As rebar coating Coating for prevention of corrosion over rebars.
}} For Cladding Fixing or refixing of slip bricks, tiles, stones & marble bedding.
}} s external rendering Weatherproof & frost resistant render, high wear & erosion resistant render.
A
As bonding slurry coat for pin hole treatment on concrete surface & as repair mortar for overhead applications.
Method of Application
1 S U R FAC E P R E P E R AT I O N
}} lean the surface with wire brush or scrubber to remove hidden dirt, loose particles. Laitance, & dust. Degrease
C
the surface by using suitable solvents
}} epair the concrete spalled portion by saw cutting the extreme edges of the repair location to a depth of at
R
least 10 mm to avoid featheredging & to provides strong substrate.
}} Clean the concrete surface to remove any contamination where breaking is not possible.
}} Roughen the surface by light scabbling or grit blasting
}} Expose corroded rebars in the repairing area fully. Remove all loose scales & corrosion deposits & immediately
clean the surface.
132
302-18/01/12
Building Repairs
Application mixing
Technical Information
PROPERTIES RESULTS
Appearance Free flowing liquid
Colour Milky white
302 Dr. Fixit Super Latex
Coverage
For Bonding & waterproofing applications
}}1 kg of super latex will cover 70 - 80 sq. ft. area in 2 coats for a proportion mix 1 : 4 : 7
(Super Latex : Water : Cement).
Recommendations for other applications are given in above tables.
Pidilite Industries Limited DISCLAIMER The product information & application details given by the company
Construction Chemicals Division & its agents has been provided in good faith & meant to serve only as a general
Ramkrishna Mandir Road, Post Box No. 17411 guideline during usage. Users are advised to carry out tests & take trials to ensure on
the suitability of products meeting their requirement prior to full scale usage of our
Andheri (E) Mumbai 400059 INDIA
products. Since the correct identification of the problems, quality of other materials
Tel +91-22-2835 7000 Fax +91-22-2835 7008
used and the on-site workmanship are factors beyond our control, there are no
www.doctor-fixit.com drfixitadvice@pilmail.com expressed or implied guarantee / warranty as to the results obtained. The company
Dr. Fixit Advice Centre (Toll Free No.) 1800-209-5504 does not assume any liability or consequential damage for unsatisfactory results,
134
Description
Dr. Fixit UniRepair FC is a specially formulated, non-shrink, fibre-reinforced high strength cementitious
mortar. It is composed of high quality cement, properly selected & graded aggregates, fibres & additives.
Dr. Fixit UniRepair FC is suitable for a wide range of concrete and masonry especially in vertical and
overhead locations because it is shrinkage compensating, high strength reinforced mortar with excellent
bonding properties, has low permeability to chloride ion penetration & CO2 diffusion
Areas of Application
Method of Application
o The heavy load bearing capacity and high mechanical strength of Dr.Fixit UniRepair FC makes it ideal for
heavy repairs and blockings
1 SURFACE PREPARATION
o The surface to be prepared must be sound & clean. It should be free of dust, loose mortars, oil, grease &
coatings
2 APPLICATION
Bedding
o The voids diameter should be at least 30mm bigger than the rod; the depth of the voids should be 10 to 15
times the diameter of the rod to be bedded. A few hours before bedding, fill the voids with water. Make sure
that there is no residual water in the voids.
o Apply Dr. Fixit UniRepair FC as in the form of sound mortar by adding water.
Blocking
o Make a solid formwork and ensure that the formwork is leak proof to avoid bleeding and leakage.
o Thoroughly wet the area and make sure that no residual water remains.
o Pour the Dr. Fixit UniRepair FC by a suitable method such as hand or pump.
o Care should be given to avoid air pockets while filling. For higher thickness Dr.Fixit Micro-concrete is
recommended. For this add 1 cm aggregate, 5 kg to 25 kg Dr. Fixit UniRepair FC.
o Use ratio Water 16% of weight motar.
o The repair areas must be clean and primed with Dr. Fixit Super Latex and allow 20 minutes for subsequent
application of UniRepair FC.
o Dr.Fixit UniRepair FC can be applied at thickness in excess of 50 mm at a time on vertical surfaces and
upto 40 mm thickness when applied in overhead work.
o Immediately after the completion of cleaning, apply the Dr. Fixit Epoxy Zinc Primer as a protective coat for
steel. The priming system to be used on the concrete substrate, will depend on the cause of the damage.
o Allow minimum 1 hour standing time between the application of Dr. Fixit Epoxy Zinc Primer and the
subsequent application of Dr. Fixit UniRepair FC.
o The decayed or damaged area of the concrete should be saw cut or cut neatly keeping the side of the area as
square as possible. Feather edging must be avoided. Test the surface for soundness; remove all loose debris,
dust and water.
o Temperature range: 5oC to 35oC. Outside this range, it is recommended to use hot mixing water (below
5oC) or cold water (above 50oC) depending on the circumstances, as well as increased care in protecting
the surface (covering with insulating materials).
o Solid and resistance supports to be used. Support is to be saturated with water a few hours prior to
installation. All residual water to be removed prior installation.
o Do not mix with other hydraulic binders. Under no circumstances should any additives be used.
Technical Information
Dosage
Packaging
o 25 kg
o Shelf life is 12 months from the date of manufacturing. Store in a cool & dry place in unopened conditions.
o As with all chemical products, caution should always be exercised. Protective clothings, such as gloves and
goggles, should be worn.
o Treat any contact to the skin or eyes with fresh water immediately. Should any of the products be accidentally
swallowed, do not induce vomiting but all for medical assistance immediately.
o Ensure the pack is available for the medical attendant to examine any relevant instructions and contents
details.
o Reseal all containers after use and ensure product is stored as instructed
Pidilite Bamco Limited DISCLAIMER The product information & application details given by the company &
(A group company of Pidilite Industries Ltd.) its agents has been provided in good faith & meant to serve only as a general guideline
during usage. Users are advised to carry out tests & take trials to ensure on the suit-
699 Modernform Tower 15 FL.,Srinakarin Rd.,
ability of products meeting their requirement prior to full scale usage of our products.
Suan Luang, Bangkok 10250, THAILAND. Since the correct identi cation of the problems, quality of other materials used and
T +662 722-8535 F +662 722-8381 on-site workmanship are factors beyond our control, there are no expressed or implied
website www.pidilitebamco.com guarantee / warranty as to the results obtained. The Company does not assume any
liability or any consequential damage for unsatisfactory results, arising from the use of
E-mail sales@pidilitebamco.com our products.