Escolar Documentos
Profissional Documentos
Cultura Documentos
Weather-Resistant
Louvres
Type WG - AWG - WGE - AWK - WG-F
TROX (South Africa) (Pty) Ltd. Tel. +27 (0)33 398 1006
10 Wigford Road Fax. +27 (0)33 398 1100
Masons Mill email : pmb@troxsa.co.za
Pietermaritzburg Website: www.troxsa.co.za
Contents Description
Description 2
Construction 3
Installation Details 5
Standard Sizes Drilling Details 7
Product Range 8
Technical Data 9
Order Details 10
2
Construction
50
50
b b
a
H
82.5
82.5
d d
c c
83 95
B
Type AWK
28
a Frame
b Blade
b c Bottom blade
d Wire mesh screen
a
H
25
B 34
Free cross-section approx. 60-%,
based on B x (H - 0.028 m)
3
Construction
Type WG-F
WG-F (steel construction) AWG-F (aluminium construction)
Blades and support mullion in formed galvanised sheet Blades of extruded aluminium sections
steel; the mullion is also powder coated black (RAL Mullion in formed galvanised sheet steel; powder coated
9005) black (RAL 9005)
Mullion is drilled at side and rear for connecting louvre Mullion is drilled at side and rear for connecting louvre
sections together or connecting to site support structure sections together or connecting to site support structure
Wire mesh screen from galvanised steel, mesh size Wire mesh screen from galvanised steel, mesh width
25 x 25 mm 25 x 25 mm
Type WG-F
u
4.1
a
H
125
b
b
37
630 B 120
180
nxB
Corner Section
20
u
60
4.2
b
630
a c u
4.1
a Blade
b Bottom blade
c Wire mesh screen
u
4.1 Right hand mullion
u
4.2 Left hand mullion
630
Components are supplied in kit form for site assembly.
Dimensions = 600 x H Fixings are included in the scope of supply.
4
Installation Details
Masonry Subframe
Type WG AWG WGE Type AWK
35
Sub-frames only for B 1197 mm and H 497 mm;
special fixing straps are available for other dimensional
t2
combinations.
Builders cleat
As delivered
t2
H + 15
t2
3
t2
B + 15 35 35 Assembly
t1 t1 122.5
Interval t = flange hole pitch (page
Materials: Builders cleat
Type WG AWG: Galvanised steel Material: Formed, galvanised sheet steel
Type WGE: Stainless steel
Installation Dimensions
Type WG Type AWG Type AWK
WGE
50
50
28
H + 35-/-B + 35
H + 15-/-B + 15
H + 28-/-B + 28
H + 15-/-B + 15
H + 35-/-B + 35
H + 26-/-B + 26
25
82.5
82.5
83 95 34
Type WG-F
x = (n x B) + 450
630 B B
5
Installation Details
H
40 40
B B
100
B1 E M E
Detail A
H1
100
H
Separating mullion
40
B
B + 15/H + 15
B1 + 35/H + 35 or H1 + 35/B + 35
B1 + 15/H + 15 or H1 + 15/B + 15
135
Opening size without masonry subframe Opening size without masonry subframe B + 15-/-H + 15
B1 + 15-/-H + 15 or H1 + 15-/-B + 15
6
Standard Sizes Drilling Details
50
28
50
A
t3
t3
~[9 ~[9
A
t2
t2
t2
20
[ 8.5
80
H
H
H
[ 4.5
t2
t2
t2
45.5
t3
t3
27.5
27.5
11.5
27.5 27.5
B E B
45.5
t1 t1 130 130 t4 t4 t1 t1
20 20
11.5
~[9
H
27.5
100 600 600 600
M = 2000
Max. B or H
Type WG AWG WGE Type AWK dimension com-
B Number of holes t1
binations that can
B H Number of holes t1 t2 t3
be used
in mm per B-side in mm
per per
in mm in mm B-side H-side in mm in mm in mm arranged B H
97- 247 In increments 1 on centre
385 330 2 225 297- 397 of 50 2 262-362 in mm in mm
585 495 2 425 447- 497 3 206-231
597- 797 3 281-381 1197 1997
785 660 2 1 625 330
897-1297 In increments 4 287-421 1297 1597
985 825 3 1 413 413 of 100
1397-1697 5 341-416 1397 1497
1185 990 3 1 513 495 1797-1997 6 352-392
1497 1397
1385 1155 3 1 613 578
1597 1297
1585 1320 4 2 475 445 437 H Number of holes t2
1697 1197
1785 1485 4 2 542 500 492 in mm per H-side in mm
1897 1097
1985 1650 4 2 608 555 547 In increments
97- 497 of 50 1997 997
1815 2 610 602
597- 797 3 281-381
1980 3 499 491
897-1297 In increments 4 287-421
1397-1697 of 100 5 341-416
1797-1997 6 352-392
Types WG AWG WGE WG-F: Any combination of dimensions B, B1 and H, H1 listed above can be supplied
7
Product Range
WG 2) WG Basic construction 11
1 2) WG- WG plus insect screen in galvanised steel 11
BM WG 1- Steel Basic construction, split on B dimension 12
Construction
BM WG- WG-BM plus insect screen in galvanised steel 12
HM WG 1- Basic construction, split on H dimension 13
HM WG-HM plus insect screen in galvanised steel 13
1) Mullion only in RAL 9005 2) Louvre also for use in combination with multi-leaf and pressure relief dampers
(see leaflet No. 3/4/EN/..)
Finish on request:
P1 = Powder coated to RAL colour S2/S3 = anodised to Euras-standard Colours: C- 0 = Natural C-33 = Medium bronze
(coating thickness approx. 60-80 m) (coating thickness approx. 20 m) C-31 = Pale bronze C-34 = Dark bronze
Price on request Finish: surface etched (E6) C-32 = Light bronze C-35 = Black
S2 = e. g. E6-C-33
3) Subframes only for B 1197 mm and H 497 mm; S3 = E6-C-0
special fixing straps are available
for other dimensional combinations.
8
Technical Data
Nomenclature Example
v in m/s: Air velocity based on cross section A A Data given: Louvre type WG, installation type B
in m2: Flow cross section: B = 585 mm, H = 495 mm, A 0.24 m2
WG WGE AWG: B x (H 0.085 m) v = 3 m/s
AWK: B x (H 0.028 m)
WG-F: B x (H 0.125 m)
(use W and H dimensions in m) Required: Total pressure drop i pt
A-weighted sound power level LWA
i pt in Pa: Total pressure drop
LW = LWO + K in dB/Oct.: Octave sound power level related to A
Octave band sound power level
of regenerated noise L
W
LWO in dB/Oct.: As before, but related to A = 1.0 m2
NC rating of sound power spectrum L W NC
LWA = LWAO + K in dB(A): A-weighted sound power level related to A
LWAO in dB(A): As before, but related to A = 1.0 m2
LW NC = LW NCO + K : NC rating of sound power level related to A Result:
LW NCO : As before, but related to A = 1.0 m2 i pt = 50 Pa (from diagram)
K : Sound power level correction for octave, LWA = 55 6 = 49 dB(A)
dB(A) or NC values at flow cross section
greater than or smaller than 1.0 m2 f in Hz 63 125 250 500 1000 2000 4000 8000
f in Hz: Octave band centre frequency LW in dB/Oct. 44 46 48 48 48 41 34 24
LW NC 52 6 = 46
8000
4000
tions- m/s
f = 63
125
250
f = 63
250
500
1000
2000
4000
1000
2000
8000
500
125
type
100
1 26 23 22 19 11 29 26 29 27 18
Pa 2 45 44 42 40 37 30 18 12 52 48 45 48 46 37 25 13
A 3 54 55 54 51 50 43 35 20 63 62 57 57 59 54 44 31
50 4 59 63 62 60 58 56 48 36 70 70 66 63 66 64 56 43
6 63 72 73 72 69 68 61 53 75 81 80 75 75 77 72 62
40
i pt
1 26 23 22 19 11 29 26 29 27 18
2 41 43 44 44 39 31 22 10 51 48 45 48 46 37 25 13
30
B 3 50 52 54 54 54 47 40 30 63 62 57 57 59 54 44 31
4 55 59 62 62 62 57 49 40 70 70 66 63 66 64 56 43
20 6 63 68 70 72 72 72 65 60 75 81 80 75 75 77 72 62
1 26 23 22 19 11 27 24 27 25 16
15 2 45 44 41 40 37 29 18 11 50 46 43 46 44 35 23 11
1.5 2 m/s 3 4 5 6 C 3 54 55 54 51 50 43 35 20 60 59 54 54 56 52 41 28
4 59 63 62 60 58 56 48 36 67 68 64 61 64 62 53 41
v 6 63 72 73 72 69 68 61 53 73 79 77 73 72 75 69 60
1 26 23 22 19 11 35 35 35 31 23 14
Type WG-F A+B
2 41 43 44 44 39 31 22 10 50 53 53 53 49 41 31 19
Installation type: D C D 3 50 52 54 54 54 47 40 30 59 62 63 64 63 57 49 37
200 4 55 59 62 62 62 57 49 40 65 68 70 71 71 67 59 49
6 63 68 70 72 72 72 65 60 72 77 80 81 82 81 75 67
150
Installation Types
50 Duct installation Plenum
installation
40
i pt
A C
H-x-B
30
B D
20
15
i pt
i pt
1.5 2 m/s 3 4 5 6
9
Order Details
Order Codes
State Colour
Size OP - Opening
ON - Neck
0 - Without WMS OF - Over Flange 0 - Natural Anodised Leave Blank
1 - WMS 25 x 25 P0 - Standard White VEP1595
2 - INS + WMS P0 - Standard White RAL9010
3 - PVC Mesh 30x30 0 - Punched and Countersunk P1 - Powder Coated to RAL...
1 - Unpunched
Specification Text
Weather resistant louvres for protection against direct ingress of
rain, leaves and birds into the intake and discharge openings of air
conditioning systems; essentially comprising border frame with
inset, rain resistant blade sections and wire mesh screen on rear.
Order Example
Make: TROX
Type: AWK / 1 / 450 x 350 / OP / 1 / P0 / VEP1595
10
Technical Data
11