Arabian Fiberglass Insulation Company Ltd.

J.V. of Zamil Industrial & Owens Corning Corp.

Complete Thermal &


Acoustical Insulation
Complete Thermal & Acoustical Insulation

Mechanical Board Insulation


Std Density : 48 kg/m3 (3.0 lb/ft3)
Product Code: Thickness R-Value Std Size : 1.2 m x 1.0 m
MBD inches ft2.hr.F/Btu Facing : Foil Reinforced Kraft (FRK)
1.0 4.35 K-Value : 0.033 w/m.C at 24C
(0.23 Btu.in/ft2.hr.F at 75F)
1.5 6.52
2.0 8.70 APPLICATION AREAS
3.0 13.04 Air-conditioning Heating Ductwork
Machine Rooms Boiler Rooms
4.0 17.39

Duct Liner
Product Code: ACOUSTICAL PERFORMANCE Density K-Value (at 24C)
DL 16 0.039
Density Thickness NRC
24 0.035
Kg/m3 mm
48 0.031
25 0.65
16 38 0.75
50 0.80 Facing: Black Glass Tissue (BGT)
25 0.75
24 38 0.90 APPLICATION AREAS
50 0.95 HVAC work
25 0.85
Perforated Suspended
Ceilings Studios
48 38 0.95
Auditorium Rooms
50 1.05 Generators Rooms

Faced Duct Wrap


Product Code: Density Thickness K-Value R-Value
FDW Kg/m3 (lb/ft3) mm ( inch) w/m.C (at 24 C) M2.C/w

12 (.75) 25 (1) 0.04 (0.28) .625 (3.57)

12 (.75) 50 (2) 0.04 (0.28) 1.25 (7.14)

16 (1.0) 25 (1) 0.039 (0.27) .64 (3.7)

16 (1.0) 50 (2) 0.039 (0.27) 1.28 (7.4)

24 (1.5) 25 (1) 0.035 (0.24) .714 (4.167)

24 (1.5) 50 (2) 0.035 (0.24) 1.282 (8.33)

48 (3) 25 (1) 0.031 (0.22) 0.758 (4.35)

48 (3) 50 (2) 0.031 (0.22) 1.515 (8.696)

CONVERSION APPLICATION AREAS


Density : 1 lb/ft3 = 16 kg/m3 Air-conditioning
Thickness : 1 in = 25.4 mm Heating ductwork
K-value : Btu.in/ft2.hr.F = 0.14286 w/m.C Containers
R-value : 1 ft2.hr.F/Btu = 0.175 m2.C/w Tanks

Duct Liner Board


Product Code: Acoustical Performance
DLB
Density Thickness NRC
Kg/m3 in mm
15 0.50
48 1 25 0.85
1 38 0.95
2 50 1.05

Std Density : 48 kg/m3 (3.0 lb/ft3) APPLICATION AREAS


Std Size : 1.2 m x 1.0 m HVAC work Perforated Suspended
Facing : Black Glass Tissue (BGT) Ceilings Studios Auditorium Rooms
K-value : 0.031 w/m.C at 10C Generators Rooms Conference Rooms
(0.21 Btu.in/ft2.hr.F at 50F)
Residential Cavity Wall Insulation
Product Code: Mean Temperatures W/m.C Btu.in/ft2.hr.F
CWI 10C 50F 0.034 0.24

24C 75F 0.035 0.24

50C 122F 0.042 0.29

75C 167F 0.047 0.33

100C 212F 0.052 0.36

Std.Normal Density : 26-27 kg/m3 1.6 1.7 lb/ft3 APPLICATION AREAS


Nominal Thermal Conductivity : (BS 874) (ASTM C 518) Poultry Farms
K or Value. Prefabricated Houses
New Residential Villa
Precast Structures
Partial or Fully Cavity Wall

Heavy Density Pipe Insulation


Product Code: Piping Fluid Runouts 25 32 64 125 200
PI System Types Temperature up to 50 & to to to &
Range C under 50 100 150 over
Heating Systems Steam and
Minimum Insulation (mm) for pipe sizes
Hot Water: High Pressure/
Temperature Medium 152-151 40 64 64 75 89 89
Pressure/
Temperature Low Pressure/ 122-151 40 50 64 64 75 75
Temperature 94-121 25 40 40 50 50 50
Low Temperature Steam 49-93 13 25 25 40 40 40
Condensate
For Feed Water Cooling Any 25 25 40 50 50 50
Systems
Chilled Water Refrigerant, 4.5-13 13 13 25 25 25 25
or Brine Below 4.5 25 25 40 40 40 40

Facing : Foil Reinforced Kraft (FRK) Normal Pipe sizes from to 26


: All Service Jacket (ASJ) APPLICATION AREAS
Density : 64-128 kg/m3 (4-8 lb/ft3) Industrial Pipes (Hot)
Temperature Chiller Pipes (cold)
Tolerance : -18C to +450C 0 to +850F Commercial/Domestic Projects
Std length : 1 m Steel/pipes & plastic piping and copper pipes

Acoustic Ceiling Panels


Product Code:
Std. Density : 56 kg/m3 (3.5 lb/ft3)
Thermal & Acoustic Performances Facing : PVC film various Design
ACP (Random Fissured, Shasta, Woven Mat, Vinta)
Thickness R-Value STC
Standard Sizes
mm m3.C/w
600 x 600 mm 610 x 1220 mm
15 0.45 50 610 x 610 mm 600 x 1200 mm
20 0.61 52
25 0.76 54 APPLICATION AREAS
Open offices Schools
38 1.15 56
Board Rooms Stores
50 1.52 64
Shopping Centers Show Rooms

Pipe Wrap Insulation


Product Code: K or Value Mean Temperature Standard Sizes
PW Btu.in/ft2.hr.F C
Thickness Width Length
0.22 24
mm m m
0.29 93
25 1 8
0.55 260
38 1 6

Density : 48 and 64 kg/m3 50 2 4


64 2 2
APPLICATION AREAS 75 3 2
Pipe Flanges Valves
Group of Pipes Tanks
Round Ducts Large Diameter Pipes
Arabian Fiberglass Insulation Company Ltd.
J.V. of Zamil Industrial & Owens Corning Corp.

Blanket Insulation
Density : From 12 up to 56 kg/m3
Product Code: Thickness Thermal
K-Value : From 0.04 0.033 w/m.C
BKT Resistance(R)
Facing : Available unfaced or
mm in m2.C/W hr .ft2.F/Btu with (FRK facing) or
25 1 0.63 4
Aluminum Foil Glass
R-Values (for K-Values=0.04)
38 1 0.95 5

50 2 1.25 7
APPLICATION AREAS
64 2 1.60 9 Prefabricated Houses
75 3 1.88 11 Cavity Walls
Partitions
89 3 2.23 13 Poultry Farms
100 4 2.50 14 Backloading of Ceiling
Sandwich Panels
150 6 3.75 21

Thermal Insulating Wool Insulation


Product Code: Mean Temperature K or Value
TIW W/M.C
Type I Type II
24C 75C 0.039 0.033
93C 200F 0.058 0.043
149C 300F 0.079 0.055

Available unfaced in two types APPLICATION AREAS


Water Heaters Boilers
TIW Type I : 16-24 kg/m density 3
Chimney Stacks Ovens
TIW Type III : 38 kg/m3 density Petrochemical Storage Tanks
Temperature Tolerance : up to +540C (+1000F)

Board Insulation
Product Code: PRODUCT Thickness (T) THERMAL THERMAL
TYPE CONDUCTIVITY
BD BD (K-VALUE)
RESISTANCE
(R-VALUE)
pes mm in W/m.C Btu.in/ft2.hr.F m2.C/W hr.ft2.F/Btu.

480 25 1 0.033 0.023 0.758 4.35(4)


(48 kg/m3) 38 1 0.033 0.023 1.152 6.52(7)
50 2 0.033 0.023 1.515 8.70(9)

640 25 1 0.032 0.022 0.781 4.55(5)


(64 kg/m3) 38 1 0.032 0.022 1.188 6.82(7)
50 2 0.032 0.022 1.563 9.09(9)
a) 960 25 1 0.032 0.022 0.781 4.55(5)
(96 kg/m3) 38 1 0.032 0.022 1.188 6.82(7)
50 2 0.032 0.022 1.563 9.09(9)

*24C/75F mean temperature


Density : From 24 kg/m3 up to 112 kg/m3 APPLICATION AREAS
Available unfaced as standard and faced upon request Precast Structures Poultry Farms
R-Values of Standard Products Internal partitions Prefab Houses
Roof (112 kg/m3)
Residential Cavity Walls (26 kg/m3)

Quiet Liner
Product Code: Acoustic Performance Density K-value
AQL Kg/m3 at 24C w/m.C
Density Thickness NRC
16 0.039
Kg/m3 mm
24 0.035
25 0.60
48 0.031
16 50 0.85
25 0.75
APPLICATION AREAS
24 50 0.95 HVAC work Studios
15 0.40 Sound Absorption Theatres
48 25 0.80 Treatment of Walls Auditoriums
Ceiling Generator Rooms
50 1.00

*Nominal Manufacturing Specifications. Check for availability of other dimensions and densities.
*The facings are also available with UL fire resistant rating.
Pre-Engineered Metal
Building Insulation
R-Values

Product Code: Thickness K-Value R-Value


MBI mm in m2.C/W hr .ft2.F/Btu mm m

25 1 0.63 4 900-1100 10-36

38 1 0.95 5 in ft

50 2 1.25 7 36-44 30-120


64 2 1.60 9
(depending
on thickness)
75 3 1.88 11

89 3 2.23 13

100 4 2.50 14

150 6 3.75 21

Std.Normal Density : 10-12 kg/m3 APPLICATION AREAS


K or = 0.040 W/m.C or 0.28 Btu.in/ft2.hr.F at Metal Building
24C or 75F mean temperature. Hangers
Facing : Foil Reinforced Kraft (FRK) Poultry Farms
: White Metalized Scrim Kraft (WMSK)

Roof Deck Insulation


Product Code: PRODUCT Thickness (T) THERMAL THERMAL
TYPE CONDUCTIVITY
RI/RD BD (K-VALUE)
RESISTANCE
(R-VALUE)

mm in W/m.C Btu.in/ft2.hr.F m2.C/W hr.ft2.F/Btu.

480 25 1 0.031 0.022 0.758 4.35(4)


(48 kg/m3) 38 1 0.031 0.022 1.152 6.52(7)
50 2 0.031 0.022 1.515 8.70(9)

640 25 1 0.032 0.022 0.781 4.55(5)


(64 kg/m3) 38 1 0.032 0.022 1.188 6.82(7)
50 2 0.032 0.022 1.563 9.09(9)

960 25 1 0.032 0.022 0.781 4.55(5)


(96 kg/m3) 38 1 0.032 0.022 1.188 6.82(7)
50 2 0.032 0.022 1.563 9.09(9)

Density : 112 kg/m 7.0 lb/ft3 APPLICATION AREAS


Temperature Roof Decks
Tolerance : -18C to +450C 0 to +850F Poultry Farms
Std length : 1m Prefabricated Houses

Woven Facing
Product Code: Piping Fluid Runouts 25 32 64 125 200
AWF System Types Temperature up to & to to to &
Range C 50 under 50 100 150 over
Heating Systems Steam and
Minimum Insulation (mm) for pipe sizes
Hot Water: High Pressure/
Temperature Medium 152-238 40 64 64 75 89 89
Pressure/
Temperature Low Pressure/ 122-151 40 50 64 64 75 75
Temperature 94-121 25 40 40 50 50 50
Low Temperature Steam 49-93 13 25 25 40 40 40
Condensate
For Feed Water Cooling Any 25 25 40 50 50 50
Systems
Chilled Water Refrigerant, or 4.5-13 13 13 25 25 25 25
Brine Below 4.5 25 25 40 40 40 40

Facing : Foil Reinforced Kraft (FRK) Normal Pipe sizes from to 26


: All Service Jacket (ASJ)
Density : 64-128 kg/m3 (4-8 lb/ft3) APPLICATION AREAS
Temperature Industrial Pipes (Hot)
Tolerance : -18C to +450C 0 to +850F Chiller Pipes (cold)
Std length : 1 m Commercial/Domestic Projects
*Nominal Manufacturing Specifications. Check for availability of other dimensions and densities.
*The facings are also available with UL fire resistant rating.
Arabian Fiberglass Insulation Company Ltd.
J.V. of Zamil Industrial & Owens Corning Corp.


Saving energy for a clean environment

H.O. & Factory: P.O. Box 1289, Dammam 31431, Saudi Arabia
Tel: +966 3 847 2901 / 847 1519
Fax: +966 3 847 3605
E-mail: wajdei@afico.com.sa
Riyadh Office: P.O. Box 50281, Riyadh 11523, Saudi Arabia
Tel: +966 1 472 5555 ext. 283
Fax: +966 1 291 0162
E-mail: kathunaiyan@afico.com.sa
Jeddah Office: P.O. Box 2140, Jeddah 21451, Saudi Arabia
Tel: +966 2 670 0020 ext. 133
Fax: +966 2 287 2283
E-mail:
Gulf Regional Office: P.O. Box 44493, Deira, Dubai, U.A.E.
Tel: +971 4 294 1211
Fax: +971 4 294 1168
E-mail: aficogcc@emirates.net.ae

Export Office: P.O. Box 90-284, Jdeidet El Metn, Beirut Lebanon


Tel: +961 1 900962
Fax: +961 1 900963
E-mail: AFICO@cyberia.net.lb

info@afico.com.sa www.afico.com.sa

Affiliate of Member of

OHSAS
18001
HE ALTH & SAFE TY
STAN DARD

Our GREEN promise


the healthy solut on
ENERGY SAVING
ENVIRONMENTALLY FRIENDLY
RECYCLED MATERIALS
SOLUTION FOR GLOBAL WARMING

AFICO is committed to a greener, cleaner environment. AFICO have responded to this


call for conservation by increasing the amounts of recycled materials in our products.
Pub No. 05-TDS-CWI Printed November 2007