FOAMULAR
(ESR-1061)
b. For steel framing, the insulation boards are attached using No. 6, Type S drywall screws, with 1-inch
(25 2 /5 mm) plastic washers, long enough to penetrate the framing a minimum of -inch (19 mm).
3. Fasteners must not be over-driven. Fasteners must be spaced a minimum of 12-inches on center around the
perimeter and 16-inches on center in the field.
JOINTSEALR
(OC 10015678-C)
1. Remove release liner backing material and center the adhesive tape over the joint to be sealed.
2. Continue to remove the liner and press the tape firmly in place over the joint. Lap intersections or joined tapes
a minimum of 3 -inches.
3. Using a J-Roller or laminate roller, roll the tape firmly in place to ensure intimate contact between tape and
substrate and to eliminate trapping air between the tape and substrate.
4. To obtain best adhesion, JointSealR Foam Joint Tape should be installed when outdoor temperatures are
170