- c This section guides you through the operations\necessary to load and execute
an EXTEST\instruction on an SN74BCT8244A.\ \You are required to follow the test
sequence\given in this assignment. When you make a mistake,\Scan Educator will explain how to correct the error.\ \Click OK or press Space to begin the assign ment. - c Your assignment is to:\ \ 1. Shift in an EXTEST instruction. \ 2. Shift in d ata to be driven \ out by the EXTEST instruction. \ 3. Return to Run-Te st/Idle. \ \Click OK or press Space to begin. - c Step 1: Shift in an EXTEST instruction.\ \To shift in an EXTEST instruction, the TAP Controller\must be moved to Shift-IR. In this state you need to\shift in the following data: 00000000\starting with the least significant bit. x 0 TMS must be 0 to move to Run-Test/Idle. x 1 TMS must be 1 to move to Select-DR-Scan. x 1 TMS must be 1 to move to Select-IR-Scan. x 0 TMS must be 0 to move to Capture-IR. x 0 TMS must be 0 to move to Shift-IR. - z The opcode for EXTEST is 00000000. 0 0 TMS and TDI must both be 0 to shift\in the first bit of the EXTEST opcode. 0 0 TMS and TDI must both be 0 to shift\in the second bit of the EXTEST opcode. 0 0 TMS and TDI must both be 0 to shift\in the third bit of the EXTEST opcode. 0 0 TMS and TDI must both be 0 to shift\in the fourth bit of the EXTEST opcode. 0 0 TMS and TDI must both be 0 to shift\in the fifth bit of the EXTEST opcode. 0 0 TMS and TDI must both be 0 to shift\in the sixth bit of the EXTEST opcode. 0 0 TMS and TDI must both be 0 to shift\in the seventh bit of the EXTEST opcode. 0 1 TDI must be 0 for the eighth bit of the EXTEST\opcode. TMS must be 1 to move to Exit1-IR.\ \Issuing one too many TCKs\in Shift-IR is a common mistake. - z x 1 TMS must be 1 to move to Update-IR. - c Step 2: Execute an EXTEST instruction.\ \To execute an EXTEST instruction, t he TAP\Controller must be moved to Shift-DR. In\this state you must shift in the \following data: 000000111110100101\starting with the least significant bit. x 1 TMS must be 1 to move to Select-DR-Scan. x 0 TMS must be 0 to move to Capture-DR. - c Note:\ \Before leaving Capture-DR, set the A B Data\Control switches to your c hoice of values\to be captured by the boundary-scan register. x 0 TMS must be 0 to move to Shift-DR. - z The data to shift in is\000000111110100101. 1 0 TDI must be 1 and TMS must be 0\to shift in the LSB of the data. 0 0 TDI must be 0 and TMS must be 0 to\shift in the second bit of the data. 1 0 TDI must be 1 and TMS must be 0 to\shift in the third bit of the data. 0 0 TDI must be 0 and TMS must be 0 to\shift in the fourth bit of the data. 0 0 TDI must be 0 and TMS must be 0 to\shift in the fifth bit of the data. 1 0 TDI must be 1 and TMS must be 0 to\shift in the sixth bit of the data. 0 0 TDI must be 0 and TMS must be 0 to\shift in the seventh bit of the data. 1 0 TDI must be 1 and TMS must be 0 to\shift in the eighth bit of the data. 1 0 TDI must be 1 and TMS must be 0 to\shift in the ninth bit of the data. 1 0 TDI must be 1 and TMS must be 0 to\shift in the tenth bit of the data. 1 0 TDI must be 1 and TMS must be 0 to\shift in the eleventh bit of the data. 1 0 TDI must be 1 and TMS must be 0 to\shift in the twelfth bit of the data. 0 0 TDI must be 0 and TMS must be 0 to\shift in the thirteenth bit of the data. 0 0 TDI must be 0 and TMS must be 0 to\shift in the fourteenth bit of the data. 0 0 TDI must be 0 and TMS must be 0 to\shift in the fifteenth bit of the data. 0 0 TDI must be 0 and TMS must be 0 to\shift in the sixteenth bit of the data. 0 0 TDI must be 0 and TMS must be 0 to\shift in the seventeenth bit of the data. 0 1 TDI must be 0 and TMS must be 1 to shift in the\eighteenth bit of the data a nd to move to Exit1-DR.\ \Issuing one too many TCKs\in Shift-DR is a common mist ake. - z x 1 TMS must be 1 to move to Update-DR. - c Step 3: Return to Run-Test/Idle.\ \To conclude the Guided Practice session,\ move the TAP Controller to Run-Test/Idle.\In this stable state the device retain s\its current state. x 0 TMS must be 0 to move to Run-Test/Idle. - c This concludes the Guided Practice. You may\now exit the program and return to the menu\(press Alt+M), or continue to experiment.