use of HFC-227ea and FM-200, extinguishes a fire quickly by discharging in 10 seconds or less ...

stopping ordinary
combustible, electrical, and flammable liquid fires before they can cause significant damage.

Safe for use where people are present. It removes heat and breaks up the fire at the molecular level. And because it
discharges as a gas, it leaves no residue and doesnt require costly clean-up like water or dry chemical systems. Perhaps
the most well respected and globally recognized of all clean agent fire suppressants, HFC-227ea applications range from
computer and electronic rooms to museums and military vehicles.

Offer environmentally responsible fire fighting performance.

Attacks fire without leaving a messy residue

It effectively extinguishes Class B and C fires by cooling and smothering and it will not conduct electricity back to the
operator.

These rechargeable extinguishers have pressure gauges and require a 6-year maintenance and a 12-year hydrostatic test.

Rugged all metal valve construction

Zero ozone depletion potential

Residue-free, will not corrode or contaminate equipment

No electrostatic shock to damage avionics

Will not conduct electricity back to the operator

saving on floor space and allowing visibility

Clean Agent Fire Protection System, which includes the use of HFC-227ea and FM-200,
leaves no residue and doesnt require costly clean-up, unlike sprinklers and other fire protection
systems. And it discharges in 10 seconds or less, extinguishing a fire quickly and effectively.

Clean Agent Fire Suppression Systems are great in applications ranging from
telecommunications and data processing to switch gear rooms, military applications and cell sites
to high-tech medical applications. HFC-227ea fire suppression is also a widely accepted
replacement for Halon 1301.

FM-200 FIRE SUPPRESSION SYSTEM Fast,


Effective Clean Agent Fire Protection

DESCRIPTION
For speed in suppressing fires, reducing damages, , Fike is the clear choice. Our

Fikes Clean Agent System uses Fikes patented rupture disc valve design offering additional
flexibility, effectiveness and speed. That translates into minimal equipment / facility damage and
little or no business interruption.
Fikes

With a Fike designed fire protection system you can count on speed and efficiency in your fire
protection, and much more.

Requires minimal container storage space


Zero ozone depleting potential
Low global warming potential
Short atmospheric lifetime
Safe for occupied areas
Full line of listings and approvals
Best warranty in the fire protection industry
Extensive line of fire protection accessories
Simplified installation
ISO 9001 certified

In addition, Fike can provide the system components and accessories to meet your complete
clean agent fire suppression system requirements. Intelligent control panels, delayed action
devices, early warning smoke detection, warning signs, manual releasing devices, automatic
detection and warning devices and fire alarm panels are all available from Fike.

Video: Clean Agent Evolution

APPLICATIONS
Computer rooms
Telecommunication centers
Records and data archives
Testing / imaging equipment
Reference material
Chemical laboratories
Clean rooms
Control rooms
Flammable liquid storage
Offshore drilling rigs
Robotic equipment
Textile manufacturing
Electric utility facilities
Media storage
Military vehicles
Art / artifacts / historical collections

IMPULSE VALVE TECHNOLOGYTHE LEADER IN RUPTURE


DISC TECHNOLOGY
RELIABILITY AND EFFICIENCY OF A RUPTURE DISC WITH THE
FLEXIBILITY OF ELECTRIC ACTUATION

Known for quality, dependable fire protection systems, Fike continues to look for ways to
improve the effectiveness of all its safety products. The Impulse Valve Technology greatly
improves the performance of clean agent fire suppression systems over mechanical valve
systems by combining the reliability and efficiency of a rupture disc with the flexibility of
electric actuation. Read more about our Impulse Technology.

PROTECTING THE PLANETNON-OZONE DEPLETING CLEAN


AGENT

LE ARN MORE

DATA CENTERS


LE ARN MORE

TELECOMMUNICATIONS


LE ARN MORE

EDUCATION


LE ARN MORE

FINANCIAL INSTITUTIONS


LE ARN MORE

GOVERNMENT

LEARN MORE

HEALTH CARE

LEARN MORE

HOSPITALITY


LE ARN MORE

MUSEUMS/GALLERIES

LEARN MORE

POWER GENERATION


LEARN MORE

OFFICE BUILDING

Gas Release Control Panel

Your LocationHome > Products > FIRE SYSTEMS > Gas Release Control System

Product Introduction

The JB-QBL-QM200 fire alarm control panel/agent releasing control panel is developed and manufactured by Fanhai
Sanjiang Electronics. As a fire alarm controller with a gas fire extinguishing function, JB-QBL-QM200 has some
functions and characteristics in full compliance with the requirements of national standards Fire Alarm Control Units
(GB4717-2005) and Automatic Control System for Fire Protection (GB16806-2006). The JB-QBL-QM200 can be
used with a local manual/auto control box, an emergency start/stop control box, a horn/strobe, a release indicator, an
agent drop display panel, a starting air cylinder, an extinguishant cylinder set and some other necessary items to form
a complete alarm and gas fire extinguishing control system. The JB-QBL-QM200 is mainly applied to the pipe
network type or non-pipe network type high/low pressure CO2 fire extinguishing system, FM-200
(heptafluoropropane) fire extinguishing system, foam fire extinguishing system, gas-aerosol fire extinguishing system,
IG541 (INERJEN) gas fire extinguishing system and other fire extinguishing systems using Halon alternatives
(haloalkane). It can be mounted with a common switching value detector to realize fire detection and alarm, and its
internal relay can control gas fire extinguishers as well as relevant alarm devices and linkages directly. It is
extensively applied in places like computer rooms, reference rooms, switchboard rooms, transformer rooms,
communication base stations, etc.

Product Features

1To connect detectors by 2 loops, and our variety of conventional smoke detectors and heat detectors ap

ply to JB-QBL-QM200..
2Its available to preset 0-
30seconds automatic delay for electromagnetic valve (electric detonator)
3To provide standalone output port for electromagnetic drive, and support 3A(24V)start
ing current.
4Keyboard lock password protection to prevent misoperation.
5To provide historical message record, and separately record alarm, trouble and agent-
releasing 999 messages for each
6All-
in trouble monitoring; gas extinguishing control panel recover automatically without man
ual operation after trouble is removed.
7To adopt low power consumption design, and standby power is available for 48hours c
ontinuous work.
8 Applications: Its applied in locations where electrical fire, solid surface fire, liquid su
rface fire and gas fire which can be cut off gas source may occur; it also matches with cab
inet-type or pipenet-
type heptafluoropropane extinguishing device, mixed gas extinguishing device IG541, S-
type aerosol extinguishing device and high-and-low pressure CO2 extinguishing device.

Technical Parameters

Content Technical Parameters


Input voltageAC220V20%,50Hz
Input power120W
Operating Voltage
Backup batteryDC24V 7.0AHConsist of two DC12V7.0Ah in ser
totally enclosed maintenance free battery
Output DC24V
Operating current Continuous operation6A
Short termless than 3 seconds8A
Length of circuit Two-wire bus 1000 meters
Detector circuits: 2, connect to conventional smoke detector and heat d
Capacity
Quantity of detectors for each circuit 20 units.
Circuit alarm threshold 9.1V
Contact capacity of relay All relay: 7A/24VDC
Electromagnetic drive3A
Output circuit current limitation
Other drive1A
Material A3 steel
Dimension 33045094mm
Mounting Wall-mount
Indoors, Temperature -
Operating environment
10+55relative humidity95%402 non condensing

JB-QBL-QM200 gas fire extinguishing controller manual

JB-QBL-QM200 fire alarm controller gas fire control controller is developed by the Shenzhen City, Sanjiang Electronics Co., Ltd. production and
production. It is a fire extinguishing function of the fire alarm controller, JB-QBL-QM200 features and characteristics in full compliance with national
standards GB4717-2005 "fire alarm controller" and GB16806-2006 "fire linkage control system" requirements, it and the scene Manual / automatic
switching control box, emergency start / stop switching control box, sound and light alarm, bleed indicator light, weightless display disk, start cylinder, fire
extinguisher bottle group composed of complete alarm and gas fire control system.
JB-QBL-QM200 is mainly used for a variety of pipe network or pipe network high / low pressure carbon dioxide fire extinguishing system, FM-
200 (heptafluoropropane) fire extinguishing system, foam fire extinguishing system, aerosol fire extinguishing system, IG541 (smoke) Systems and other
alternative halon (haloalkane) fire extinguishing systems. Can be connected to the ordinary switch detector, fire detection and alarm; through the

JB-QB-QM200-4 gas fire extinguishing controller basic operation


JB-QB-QM200 / 4 type gas fire control basic operation
1, boot state: the system has a power input (AC or backup battery), the power indicator is lit, the system self-
test run.
The system set the keyboard lock to prevent misuse: turn on the keyboard lock first press the "keyboard
operation" button and then press the "tune" key to open the keyboard, key operation light is lit. When the keyboard is
closed, press the "keyboard operation" button, the keyboard operation light goes out.
1) adjustment: you can press the "tune" key and "tune" key to complete the time adjustment.
2) Reset: When the keyboard is in operation, press the "Restore" button, the system will eliminate all the alarm,
and initialize all the output.
3) When the system fails, the corresponding fault indicator on the controller is on.
Description:
When the keypad lock is off, the "manual deflated" key, the "silencer" key, and the "voltage test" key are still
valid.
Press the "Self / Hand" key on the controller to switch the manual automatic state. The manual / automatic
switch of the capacitor compartment door must first hit the corresponding position, and the "self / hand" key operation
on the controller can be effective.
2, the occurrence of fire alarm when the operation and processing
When there is a fire alarm and fire alarm light, you should immediately check the fire area, to confirm whether
there is a fire: If you confirm a fire, should take the appropriate measures according to the fire.
If the alarm is false, the following measures should be taken:
1) check the false alarm fire parts are too large dust, the temperature is too high to confirm whether it is due to
human or other factors caused by false alarm;
2) Press the "keypad" button and then press the "Reconciliation" button, then press the "Restore" button to
restore the normal state of the controller, observe whether it will be false positives; if still false positives can be
isolated and notified as soon as possible Installation unit or factory maintenance. If a fire occurs, you need to start the
gas fire extinguishing equipment, then press the controller on the "manual deflated" button, this time the system will
start the solenoid valve delay, and issued a variety of sound, light alarm.
Note: When the system is in the deflated countdown state, the "Pause" key is not closed by the keypad lock,
and the "Pause" key is valid. Pressing the "Pause" key stops the countdown immediately.
3, the general failure of the exclusion method
1) When the fire occurs when the solenoid valve and various linkage devices start the system to produce a
slight humming, it may be that the system is working properly because there is a large current output system Internal
cooling fan starts when the output current decreases when the fan will automatically shut down
2) When the manual deflator button is inactive, check that the system is in a paused state
3) Check whether the fuse F10 of the motherboard is blown when the internal power supply is normal but can
not be externally output
4) When there is no AC input, check whether the standby switch is turned on when the battery is not connected
5) When the AC input system is reported, the AC input voltage may exceed the range of 1755V AC-280V5V
AC, and the system power module will enter the protection state. Please confirm the AC input voltage
6) system alarm delay is longer when the system may be in a strong interference environment should check to
confirm whether the system is well grounded

JB-QB-QM200 Gas Extinguishing Controller Basic Operation (A4)


JB-QB-QM200 gas fire extinguishing controller basic operation
1, boot state: the system has a power input (AC or backup battery), the power indicator is lit, the system self-
test run.
The system set the keyboard lock to prevent misuse; open the keyboard lock first press the "keyboard
operation" button and then press the "tune" key to open the keyboard, the keyboard operation light is lit. When the
keyboard is closed, press the "keyboard operation" button, the keyboard operation light goes out.
1) adjustment: you can press the "tune" key and "tune" key to complete the time adjustment.
2) Reset: When the keyboard is in operation, press the "Restore" button, the system will eliminate all the alarm,
and initialize all the output.
3) When the system fails, the corresponding fault indicator on the controller is on.
Description:
When the keypad lock is off, the "manual deflated" key, the "silencer" key, and the "voltage test" key are still
valid. Press the "Self / Hand" key on the controller to switch the manual automatic state. The manual / automatic
switch of the capacitor compartment door must first hit the corresponding position, and the "self / hand" key operation
on the controller can be effective.
2, the occurrence of fire alarm when the operation and processing
When there is a fire alarm and fire alarm light, you should immediately check the location of the fire to confirm
whether there is a fire; if confirmed that a fire occurred, should take the appropriate measures according to the fire.
If the alarm is false, the following measures should be taken:
1) check the false alarm fire parts are too large dust, the temperature is too high to confirm whether it is due to
human or other factors caused by false alarm;
2) Press the "keypad" button and then press the "Reconciliation" button, then press the "Restore" button to
restore the normal state of the controller, observe whether it will be false positives; if still false positives can be
isolated and notified as soon as possible Installation unit or factory maintenance.
If a fire occurs, you need to start the gas fire extinguishing equipment, according to the controller on the
"manual deflated" button, then the system will delay the start solenoid valve, and issued a variety of sound, light
alarm.
Note: When the system is in the deflated countdown state, the "Pause" key is not closed by the keypad lock,
and the "Pause" key is valid. Pressing the "Pause" key stops the countdown immediately.
3, the general failure of the exclusion method
1) When the fire occurs when the solenoid valve and various linkage devices start the system to produce a
slight humming, it may be that the system is working properly because there is a large current output system Internal
cooling fan starts when the output current decreases when the fan will automatically shut down
2) When the manual deflator button is inactive, check that the system is in a paused state
3) the system internal power supply is normal but can not be external output check the motherboard fuse F10 is
broken
4) When there is no AC input, check whether the standby switch is turned on when the battery is not connected
5) When the AC input system is reported to the main power failure, the AC input voltage may exceed the range
of 175V5AC-280V5VAC. At this time, the system power module will enter the protection state. Please confirm the AC
input voltage
6) system alarm delay is longer when the system may be in a strong interference environment should check to
confirm whether the system is well grounded

"Gas Extinguishing System (JB-QBL-QM200)" Parameter Description

Scope of application: Public places Material: stainless steel

"Gas fire extinguishing system (JB-QBL-QM200)" details

Model: JB-QBL-QM200

for a variety of pipe network or pipe network high / low carbon dioxide fire extinguishing system, heptafluoropropane fire extinguishing system, foam

fire extinguishing system, aerosol fire extinguishing system, smoke foaming fire extinguishing system and other alternative halon Of the fire extinguishing

system.
Features:

1, the use of improved code redundancy and digital de-noising technology for smoke density and temperature detection to ensure high stability of the

system;

2, the district control panel to provide a fire alarm output, composite fire alarm output function;

3, district Dashboard separate solenoid driver output port;

4, 0 to 39 seconds can be preset solenoid valve (squib) automatic start delay time, and providing a starting countdown;

5, low-power design system, backup power continuous working time of greater than 48 hours;

6, keyboard lock password protection to prevent misuse;

7, having a function of recording the history information;

8, distinguished system failure, fire, gas discharge delay deflation of four states, namely, to give the corresponding The sound of light alarm.

Technical parameters:

System capacity: single area, two loops, the number of detectors per loop can be accessed <= 20 (common detector)

relay contact capacity: 7A / 24V DC

output circuit current limiting: solenoid valve drive output circuit: <= 3A, other drive output circuit: <= 1A

Operating voltage: AC 220V 20%, 50Hz

Working environment: Temperature: -10 C ~ +55 C, relative humidity: <= 95% RH

Dimensions: 330 450 94mm

installation: wall-mounted

battery backup: 24V / 7A