Você está na página 1de 1

GENERAL NOTES

25 24 22 20 19 1. ALL DIMENSIONS ARE IN mm

REFERENCE DRAWINGS
REV. REV.
DESIGN DRAWING NO SHOP DRAWING NO
NO NO
8355 9820 7050 5575 ATR-DT3-AR-DWG- 3062-01 R0 ATR-SPLL(MAX)-EL-DWG-GN-TYP-5001 R1

ATR-DT3-AR-DWG- 3589 R0
ATR-DT3-AR-DWG- 3590 R0
SEC SEC
ATR-DT3-AR-DWG- 3591 R0
Y W
CKR-2540-VT-LC-101-00 R1
VDP

CWT822J
TOTO

CWT822J(T1)
TOTO

TOTO
CWT822J(T1)

TOTO
CWT822J

10000
TOTO
CWT822J(T1)

TOTO
CWT822J

TOTO
CST320

CWT822J(T1)
CWT822J
TOTO

TOTO

LT240C
TOTO
LT240C
REF

TOTO

CST320
TOTO
CWT822J(T1)
CWT822J
TOTO

TOTO
TOTO
CWT822J(T1)

DW
WM
WH
SEC SEC
TOTO
CWT822J

PAY1780E
TOTO
Z VDP
Z

REF
TOTO
PAY1780E WM DW
VDP
WH
PROJECT
E COLOMBO RESIDENTIAL TOWER
VOID

1675
COLOMBO, SRI LANKA

SEC
SEC
Y W
F CLIENT
INDOCEAN DEVELOPERS (PVT) LIMITED

2600
EXTRACT DUCT
ELEV B4 ELEV B5 ELEV B6 ELEV B7 DESIGN ARCHITECT
SAFDIE ARCHITECTS, LLC.
100 PROPERZIE WAY
G SOMERVILLE, MA 02143-3740 USA
T 617.629.2100 F 617.629.2406
UP
ASSOCIATE ARCHITECT

2750

31600
DESIGN TEAM 3
SINGAPORE
DN T 658.499.7168
STRUCTURAL ENGINEER
H MR. PREDRAG EROR
P.O. BOX 102803, DUBAI, UAE
ELEV B2 ELEV B3 T 9714.3629234 F 9174.3629234

12

13

14

15

16

17

18

19
20
11

2900
10 ELEV B1 MECH, ELECT, PLUMBING ENGINEER
CKR CONSULTING ENGINEERS PVT. LTD.
09

08

07

06

05

03

02

01
04
PO BOX 73889
DUBAI, UAE
J T +97143384277
LANDSCAPE ARCHITECT

1675
VOID P LANDSCALE CO., LTD.
59/3 SOI SUKHUMVIT 39 SUKHUMVIT ROAD, KLONGTON NUA
K WATTANA, BANGKOK 10110 T. 662.261.3700.9
VDP
LOCAL STRUCTURAL ENGINEER & SUPERVISION CONSULTANT
TOTO

DEEPAL WICKREMASINGHE ASSOCIATES


REF REF
PAY1780E

WM
KED
WH 300x450
NO. 377/2, Thalawathugoda Road, Hokandara South, Sri Lanka.
SEC VDP
SEC T- +94 11 4402395
DW

X X
ISSUE
CWT822J(T1)

CWT822J
TOTO

TOTO

TOTO
CWT822J(T1)

NO. DESCRIPTION DATE


DW

TOTO

00 FOR APPROVAL 21.10.2016


CWT822J

01
02
03

10000
04
05
CO-0RDINATION CERTIFICATE
S. NO DISCIPLINE DATE SIGNATURE
1.
TOTO
CWT822J

TOTO
CWT822J(T1)

TOTO
CWT822J(T1)

TOTO
2.
CWT822J

3.
4.
KEY PLAN
L
H F D B

G E C A

ALTAIR
Indocean Developers (Pvt) Ltd
No: 121A, Sir James Peiris Mawatha Main Contractor
E D Colombo 02
25 24 22 21 20 19
Approved
Approved as Corrected
Submit Specified Item
FIN.CEILING = L+2550MM

FIN.CEILING = L+2400MM
CUBICLE TOP
FIN.CEILING = L+2 400
CUBICLE TOP
FIN.CEILING = L+2 400 FIN.CEILING = L+2400MM
FIN.CEILING = L+2 400
FIN.CEILING = L+2 550 Revise and Resubmit
Rejected Sub Contractor
FIN.CEILING = L+2 400

MAXAIRE (PVT) LTD


110 , Isipathana Mawatha,
The review is only for general conformance Colombo 05.
with the design concept of the project and T : +94 11 2501370, 2501305, 4641477
F : +094 11 2589860
general compliance with the information given E : info@maxaire.net
in the Contract Documents. Contractor is
S.O.P.
responsible for: Dimensions to be confirmed DISCIPLINE ELV
and correlated at the job site; information that
SECTION- X X pertains solely to the fabrication processes or
SECTION W UNIT- F ( EVEN NUMBERS LEVEL )
SCALE: 1:100 SECTION W W - UNIT F to the means, methods, techniques, DRAWING TITLE
SCALE: 1:100 sequences, and the procedures of
constructions; coordination of the Work of all VERTICAL TOWER LEVEL
19 20 22 24 25 D E
trades; and for performing all work in a safe ( ODD NUMBERS ) 33
and satisfactory manner.
TELEPHONE, DATA AND ELV CONDUIT LAYOUT
Any approval from the Engineer/Consultant of
submittals, materials and workmanship etc.
FIN.CEILING = L+2550MM
FIN.CEILING = L+2550MM

FIN.CEILING = L+2400MM shall not relieve the Contractor of his sole Detailed Drawn Checked Approved Scale Size
responsibility and obligation to comply with
all requirements under the Contract. 1:100
Udayashantha Hirushan Fazal Faizal A1
Consultant/Engineer Date Date Date Date
20.09.2016 20.09.2016 20.09.2016 20.09.2016
Reviewer
Drawing Number Rev.
SECTION - Z Z
SECTION Z ( EVEN NUMBERS LEVEL )
SCALE: 1:100 SECTION Y Y - UNIT H Signature Date ATR-SPLL(MAX)-LV-DWG-VT-L33-1323 0
SCALE: 1:100
Status
SHOP DRAWING

Você também pode gostar