Humidur FP
Product Description
Humidur FP is a 2-component solvent-free modified polyamine cured epoxy system offering
the following benefits:
Long term protection in highly corrosive environments: life expectancy over 30 years
High chemical resistance to acids, alkalis, acids, oils, lubricants, detergents, ...
Surface tolerant & Outstanding adhesion to substrate and interadhesion between layers
Capable of curing under water: can be exposed to water immediately after application
Unlimited overcoating
Resistant to temperatures from -35C to 150C and to most fluids between pH 0 and pH
14 (see Humidur chemical resistance list)
Compatible with fire protection coating Multifire basecoat S707-120 and SC901/SC902
(70 minutes heat resistance at 300-350C)
Manufacturers Information
Acotec nv, with registered offices at Aalst, Belgium, is the developer and sole manufacturer of
the Humidur products, distributed worldwide through a wide network of agents and coopera-
tive companies. The proven lifetime of the Humidur coatings in practice is more than 30
years. Contact Acotec directly or visit www.acotec.be or www.humidur.be for reference pro-
jects.
Industrielaan 8 T: +32 53 83 86 60
Acotec nv Zuid III F: +32 53 83 69 88
Date: 19/04/2016
9320 Erembodegem (Aalst) M: info@acotec.be
LETS FACE CORROSION Belgium W: www.acotec.be & www.humidur.be Pg. 1/6
TDS - Humidur FP
Composition
Humidur FP consists of two components:
A is the base component and contains:
non-crystallisable epoxy resins,
high-tech modifying agents and elastifiers,
lamellar abrasion and impact resistant fillers,
colouring pigments
B is the hardener and contains:
polyamine hardener complex
Recommended Use
In the Humidur product range, Humidur FP has the highest chemical resistance offering solu-
tions to:
Marine structures in extreme corrosive environments : splash zone, atmospheric and sub-
merged steel
Offshore and petrochemical structures (submerged, splash zone and tidal movements)
Storage tanks that hold petroleum, diesel and chemical products
Pipelines in oil and gas or penstocks in hydropower facilities
Humidur FP comes in three variants: FP Single (also known as FP Hydro), FP Plural and FP
Brush. Each has been developed for specific application means:
FP Single (known
PRODUCT USE FP Plural FP Brush
as FP Hydro)
Stripe coat Yes / Yes
By Brush
Thick layers Yes / Yes
By Spray One layer Yes Yes /
(heated hoses) Multiple layers Yes Yes /
T: +32 53 83 86 60
Acotec nv Industrielaan 8
F: +32 53 83 69 88
Zuid III
Date: 19/04/2016
9320 Erembodegem (Aalst) M: info@acotec.be
LETS FACE CORROSION Belgium W: www.acotec.be & www.humidur.be Pg. 2/6
TDS - Humidur FP
Product Data
FP Single (known
SPECIFIC DATA FP Plural FP Brush
as FP Hydro)
Colour (gloss) Any RAL colour Any RAL colour Any RAL colour
(For colour stability (only esthetic) , apply 25 colours immedia- 25 colours imme- 25 colours immedia-
Humidur TC on top of Humidur FP) tely deliverable diately deliverable tely deliverable
Compatibility with Cathodic Pro-
Yes Yes Yes
tection Systems (ISO20340)
Mixing ratio
By weight 5:1 4:1 3,7 : 1
A:B By volume 3,8 : 1 2,9 : 1 3,475 : 1
Standard packaging 18 kg 22 kg 5 kg
T: +32 53 83 86 60
Acotec nv Industrielaan 8
F: +32 53 83 69 88
Zuid III
Date: 19/04/2016
9320 Erembodegem (Aalst) M: info@acotec.be
LETS FACE CORROSION Belgium W: www.acotec.be & www.humidur.be Pg. 3/6
TDS - Humidur FP
Curing time
Humidur coatings have the ability to cure under water. The curing of Humidur is a chemical
reaction and is water repellent. The curing times depend on air circulation, temperature and
the film thickness. The touch dry time at 20C is 3 hours. For a full cure, the indicative values
are:
10C (50F) 15C (59F) 20C (68F) 25C (77F) 30C (86F)
Full cure 3 days 2 days 24 hours 12 hours 8 hours
Application
All surfaces shall be free of oil, grease, dust or any other contamination prior to coating.
SURFACE
Expected life
PREPARA- Cleanliness Methods Roughness Warranty
time
TION
Hand tool
Power tool
St 2 - 3 (wire brush, need- Original Profile
Minimum 15 years On request
ISO 8501 le gun, bristle
blaster, grind
disk)
60 10 m
Sa 2
Optimal Gritblasting 2/3 reference > 30 years On request
ISO 8501
ISO 8503
Application temperature of
35C 50C 25C
mixture
Surface tem- Minimum Dew point + 3C Dew point + 3C Dew point + 3C
perature Maximum 50C 50C 50C
Relative Humidity < 95% < 95% < 95%
Humidity
Surface No condensation No condensation No condensation
Opening 0,019 - 0,023 0,019 - 0,023 0,019 - 0,023
Spray nozzle
Angle 40-60 40-60 40-60
T: +32 53 83 86 60
Acotec nv Industrielaan 8
F: +32 53 83 69 88
Zuid III
Date: 19/04/2016
9320 Erembodegem (Aalst) M: info@acotec.be
LETS FACE CORROSION Belgium W: www.acotec.be & www.humidur.be Pg. 4/6
TDS - Humidur FP
Environment
Humidur FP has been designed to fully respect the environment. The product contains:
No coaltar,
No isocyanates,
No heavy metals.
Humidur FP is capable of curing under water without leaching taking place and has no detri-
mental effect on the sediment, fauna and flora in and out of the water. When using Humidur
FP on static marine structures, the biofilm can form itself on top of the Humidur coating with-
out affecting the substrate and without any loss of the anti-corrosion properties.
As Humidur is a one-layer system, it reduces the amount of waste and minimizes loss spray.
Insurance
After application, an adhesion test is performed (according to ISO 4624) for which we commit
ourselves to achieve a minimum criterion of 8 MPa.
A corporate warranty can be given under certain conditions. More information upon report.
An insurance policy of 10 years, given by HDI Gerling, is available on all Humidur coatings
in case of optimal surface preparation. For the terms and conditions on this warranty, please
contact Acotec nv directly.
Approvals/Certificates
Approved in petrochemical industry and offshore oil and gas market by: Shell, Statoil,
ConocoPhilips, Talisman Energy, Maersk Offshore, Transocean Drilling, Fairfield En-
ergy
University Ghent: Approval for resistance against Microbially Induced Corrosion (MIC)
T: +32 53 83 86 60
Acotec nv Industrielaan 8
F: +32 53 83 69 88
Zuid III
Date: 19/04/2016
9320 Erembodegem (Aalst) M: info@acotec.be
LETS FACE CORROSION Belgium W: www.acotec.be & www.humidur.be Pg. 5/6
TDS - Humidur FP
Approvals/Certificates
SGS: Resistance to liquids of Humidur FP (EI 1541 + ISO 2812-1)
Force Technology: Fuel and water resistance testing of Humidur FP (MIL-PRF 4456F )
Royal Haskoning: Most cost-effective anti-corrosion solution (Life Cycle Cost Analysis)
Approved by CCS for above and below ships waterline and the inside of tanks
T: +32 53 83 86 60
Acotec nv Industrielaan 8
F: +32 53 83 69 88
Zuid III
Date: 19/04/2016
9320 Erembodegem (Aalst) M: info@acotec.be
LETS FACE CORROSION Belgium W: www.acotec.be & www.humidur.be Pg. 6/6