Você está na página 1de 14

Parent Alarm

No.
Alarm ID Alarm Text SEVERITY Alarm ID

71058 NE O&M CONNECTION FAILURE MAJOR 71058


1
71103 ID CONFLICT IN BTS O&M CONNECTION MAJOR 71103
2
7650 BASE STATION FAULTY MAJOR 3080
3
7650 BASE STATION FAULTY MAJOR 2056
4
7650 BASE STATION FAULTY MAJOR 3000
5
7653 CELL FAULTY MAJOR 3030
6
7653 CELL FAULTY MAJOR 3070
7
7653 CELL FAULTY MAJOR 3020
8
7653 CELL FAULTY MAJOR 3003
9
7653 CELL FAULTY MAJOR 4045
10
7653 CELL FAULTY MAJOR 3000
11
7653 CELL FAULTY MAJOR 4001
12
7653 CELL FAULTY MAJOR 4261
13
7653 CELL FAULTY MAJOR 4090
14
7653 CELL FAULTY MAJOR 1900
15
7653 CELL FAULTY MAJOR 1837
16

7653 CELL FAULTY MAJOR 4309


17
7653 CELL FAULTY MAJOR 3010
18
7406 External AL 6 MAJOR
19
7654 CELL OPERATION DEGRADED MAJOR 3010
20
7654 CELL OPERATION DEGRADED MAJOR 1838
21
7654 CELL OPERATION DEGRADED MAJOR 4045
22
7654 CELL OPERATION DEGRADED MAJOR 3030
23
7654 CELL OPERATION DEGRADED MAJOR 1837
24
Minor 4011
25 7652 BASE STATION NOTIFICATION
Category Action

Supplementary Information Required


NE O&M CONNECTION FAILURE SD On Site TS

ID CONFLICT IN BTS O&M CONNECTION SA Remote TS

BTS reference clock missing SA On Site TS

SA On Site TS
Reference clock missing in startup
System Module failure SA On Site TS

Failure in optical interface SA On Site TS

Configuration error: BTS config error (Not enough HW for LCR) SA On Site TS

Baseband bus failure SA On Site TS

Failure in replaceable baseband unit SA On Site TS

Antenna Line Switched Of SA On Site TS

System Module failure SA On Site TS

BTS reset required SA Remote TS

Cell state audit alarm SA Remote TS

Cell power failure SA On Site TS

RF Module configuring failed SA On Site TS

VSWR Major Alarm SA On Site TS

SA On Site TS
Connection Unstable At 6Gbps
RF Module failure SA On Site TS

High Temperature Potentially SA On Site TS

RF Module failure SA On Site TS

VSWR minor alarm SA On Site TS

Antenna Line Switched Of SA On Site TS

SA On Site TS
Failure in optical interface
SA On Site TS
VSWR major alarm
SA On Site TS
GPS Receiver alarm: control interface not available
NEED TT DIRECT OR

DELAY TT
YES DIRECT

YES DIRECT

YES DIRECT

YES DIRECT

YES DIRECT

YES DIRECT

YES DIRECT

YES DIRECT

YES DIRECT

YES DIRECT

YES DIRECT

YES DIRECT

YES DIRECT

YES DIRECT

YES DIRECT

YES DIRECT

YES DIRECT

YES DIRECT

YES DELAY

YES DELAY

YES DELAY

YES DELAY

YES DELAY

YES DELAY

YES DIRECT
Sn Version Number Date

1 V1.2 8-Aug-16
Changes

1)Change Action Required for Alarm Text ID CONFLICT IN BTS O&M CONNECTION by
Remote Tshot before On site TS
No. Parent Alarm
Alarm ID Alarm Text SEVERITY Alarm ID

71058 NE O&M CONNECTION FAILURE MAJOR 71058

71103 ID CONFLICT IN BTS O&M CONNECTION MAJOR 71103

7650 BASE STATION FAULTY MAJOR 3080

7650 BASE STATION FAULTY MAJOR 2056

7650 BASE STATION FAULTY MAJOR 3000

7653 CELL FAULTY MAJOR 3030

6
7653 CELL FAULTY MAJOR 3070

7653 CELL FAULTY MAJOR 3020

7653 CELL FAULTY MAJOR 3003


9

7653 CELL FAULTY MAJOR 4045


10

7653 CELL FAULTY MAJOR 3000


11

7653 CELL FAULTY MAJOR 4001

12

7653 CELL FAULTY MAJOR 4261

13

7653 CELL FAULTY MAJOR 4090


14

7653 CELL FAULTY MAJOR 1900


15

7653 CELL FAULTY MAJOR 1837

16
CELL FAULTY MAJOR 4309

17 7653

7653 CELL FAULTY MAJOR 3010

18

7654 CELL OPERATION DEGRADED MAJOR 3010

19

7654 CELL OPERATION DEGRADED MAJOR 1838

20
Action
Category
Supplementary Information Required

NE O&M CONNECTION FAILURE SA On Site TS

ID CONFLICT IN BTS O&M CONNECTION SA Remote TS

BTS reference clock missing SA On Site TS

SA On Site TS

Reference clock missing in startup

System Module failure SA On Site TS

Failure in optical interface SA On Site TS


Configuration error: BTS config error (Not enough HW for LCR) SA On Site TS

Baseband bus failure SA On Site TS

Failure in replaceable baseband unit SA On Site TS

Antenna Line Switched Of SA On Site TS

System Module failure SA On Site TS

BTS reset required SA Remote TS

Cell state audit alarm SA Remote TS

Cell power failure SA On Site TS

RF Module configuring failed SA On Site TS

VSWR Major Alarm SA On Site TS


SA On Site TS

Connection Unstable At 6Gbps

RF Module failure SA On Site TS

RF Module failure NSA On Site TS

VSWR minor alarm NSA On Site TS


NEED TT DIRECT OR Meaning Instruction
DELAY TT

This alarm is raised when the BTS


O&M connection between the OMS
and a network element (eNodeB)
YES DIRECT fails. Site down cause the
connection fail.The managed Check if transmission or
network element is not reachable Power causing the site
by the centralized O&M systems down that triggering this
like the OMS or the NetAct alarm
Two or more network elements,
that try to communicate to OMS,
YES DIRECT have the same network element
id.OMS can not communicate with
the network elements that have the
same id

This BTS fault indication is


generated if the reference clock
monitoring function of the BTS For TDD Reset eNodeB
YES DIRECT does not receive the configured or For FDD change to
synchronization reference signal, if available shyncronization
all the synchronization reference
signals are missing, or if the BTS
has been in holdover mode and
holdover time is run out (TDD only)

Phase synchronization has been


commissioned at the
YES DIRECT btsSyncMode, but PPS and/or ToP
reference clock has not become
available during timeout, that is,
waited for during startup Replace GPS Module
The BTS has detected an Flexi BTS FDD, Flexi BTS
abnormal operation or a failure in TDD:
the internal functionality of the 1. Reset the System
System Module. The System Module.
YES DIRECT Module internal communication or 2. Replace the System
synchronization problem. All signal Module.
processors inside the System
Module are unstable. 2. The FSP
on system module is faulty, the
FSP is not mapped to any cell and
all FSPs in BTS are faulty_x000D_
_x000D_

Check the cables


The BTS has detected an between the system
YES DIRECT abnormal operation or a failure in module and RF module.
an optical interface between two Note that dirty optical
modules. The failure cannot be connectors might cause
attributed to a specific module but the signal level to drop
there are several possible fault too low. Or Optical
sources. broken causing this
alarm
YES DIRECT There is a compatibility problem in
the BTS HW/SW versions or the Check Optical Cable
HW/HW configuration. Another connection between
possibility is that there is a System Module and RF
mismatch in the BTS configuration Module

The BTS has detected an


abnormal operation or a failure in
the BTS internal or external (optical Check Optical
YES DIRECT link) baseband bus. The failure Connection between
cannot be attributed to a specific FBBA and RF Module or
module but there are several Check FBBA module
possible fault sources itself
The BTS has detected an
YES DIRECT abnormal operation or a failure in Flexi BTS FDD, Flexi BTS
the BTS replaceable TDD:
baseband unitRF module has been
The Tx in the Check
1. ResetFBBA
the module
System
switched off to protect the radio Check
Module. Jumper Cable
YES DIRECT module hardware, which might be Installation and its
2. Replace the System
damaged because of high Connectors
Module.
reflection
The (VSWR)
BTS has conditions.
detected an
YES DIRECT abnormal operation or a failure in
the internal functionality of the
System Module._x000D_The FSP
on system
This fault ismodule
reportedis to
faulty and
notify thethe
FSP is mapped
operator that thetoBTS
the must
cell reset to
_x000D_
solve a problem that has been
YES DIRECT discovered by the BTS O&M
system, and that BTS O&M will not
trigger an autonomous reset on its
own
The cell state audit detected that
the cell was unintentionally
YES DIRECT deactivated without warning.
Symptom data is automatically
collected
The Flexi Radio Module has
YES DIRECT detected low downlink carrier input
power from the Flexi System
Module Check FPFD Module

Reset RF Module and if


YES DIRECT The RF module configuration has still not clear replace the
failed because of HW or SW fault module

The VSWR value exceeds the level


that is defined as criterion for
VSWR major event or exceeds the
YES DIRECT define threshold (VSWR Major
Threshold 1.9) . The impedance of
the antenna line does not match
the impedance required by the Check Jumper Cable
Radio Module. Installation and its
Connectors
RP30-1 connection between the
system module and radio module
YES DIRECT or between extension baseband
module (FBBx)and radio module is
not stable at 6Gbps Replace related SFP

The BTS has detected an


abnormal operation or a failure in
the internal functionality of the RF
YES DIRECT Module. A critical HW/SW fault
inside the RF Module. The cell
cannot operate because of not
enough available and needed Check RF Module and
resources: Tx or Rx Replace the Module

The BTS has detected an


abnormal operation or a failure in
the internal functionality of the RF
YES DELAY
Module. The cell can still operate
because it still has enough
available and needed resources: Check RF Module and
both Tx and Rx Replace the Module

The VSWR value exceeds the level


that is defined as criterion for
YES DELAY VSWR major event or exceeds the
define threshold (VSWR Minor
Threshold 1.5). The impedance of
the antenna line does not match Check Jumper Cable
the impedance required by the Installation and its
Radio Module. Connectors