Flexible ducting
Lindab 1
Safe 3
Silencers 4
Roof hoods 8
Transfer 10
Rectangular 11
Flexible ducting 12
Isol 13
Access doors 14
Smart tools 15
Index 18
lindab | f lex ible and semiflexible products
9
Semiflexible duct
SRFW ........................................... 595
10
11
Silencers
Flexible ducts
12 AKUCOM ..................................... 598
FSA .............................................. 599
FSAFU.......................................... 600
13
14 FBLDFSL...................................... 601
15
Semiflexible
double duct
16 SLFA 25 ....................................... 602
SLFA 50 ....................................... 603
17
18
DRATU
DRATMF AL
DRATMFU
6
AP Glass AP or Flexible Insulated Budget
FIBLD budget wool PMP Light Duct
Insulated ducts
light 25 mm 7
Glass
wool Flexible Insulated
SRFW AL+AL AL+AL
25 or Double Duct
50 mm 8
Glass Flexible Duct
FDFI PE wool AP Foil Insulation
25 mm
Mineral 9
AKUCOM AL wool PE
25 mm
FBLDFSL AP light
Glass
wool PMP Flexible Light Duct 10
Foil Silencer
25 mm
Silencers
Materials 14
AL = Aluminium
AP = Aluminium-polyester
GALV = Galvanized steel 15
MP = Metalized Polyester
PMP = Metalized Polyester 16
PE = Polyester
PVC = Polyvinyl Cloride 17
18
100 15
0
100 0,5
10
d [m
14 5
2 r= d
16 0
12
18 0 m]
10 20 0 1
0 r = ,5
d
0
31 0
25
s]
35 5
28
40 5
=
m/
45 0
r
5 0
v[
55 00
d
63 0
3 10 5 2
0
4 r =
pt
pt
2
4 1
10
5
0,1
10 100 1000 10000 [l/s]
[m/h]
6 100 1000
q
10000
1
3 10 15 [m/s]
v
7 Semiflexible ducts
[Pa/m]
20
63
80
15 d [m
0
10
m]
8
5
100
12
10
0
16
0
]
/s
20
0
[m
25
5
31
v
0
40
5
50
4
9 10 3
pt
10 1
11 0,1
5 10 100 1000 5000 [l/s]
13
14
15
16
17
18
d
3
l
4
Description 6
Reinforced PVC encapsulating a bronze coated wire helix. d O A l Max.
d d2/4 pressure
nom m m2 mm Pa
Classifications 7
Reaction to fire class E acc. to EN 13501-1 80 0,251 0,005 6000 +3000
102 0,320 0,008 6000 +3000
127 0,399 0,013 6000 +3000 8
Technical data 152 0,478 0,018 6000 +3000
Duct materials ..................... Glass fiber reinforcing 160 0,509 0,021 6000 +3000
coated with fire retardant 203 0,638 0,032 6000 +3000 9
PVC 254 0,798 0,051 6000 +3000
Temperature range .............. -30 to +80 C
315 0,990 0,078 6000 +3000
Maximum air velocity .......... 30 m/s
406 1,275 0,129 6000 +3000
10
Packing ............................... Individual box
11
12
13
14
15
Ordering example 16
KF 162 6000 PVC
Product
Dimension d
17
Length l
Material
18
d
3
l
5 d O A l Max.
d d2/4 pressure
nom m m2 mm Pa
Description 80 0,251 0,005 10 000 +3000
6
Reinforced PVC encapsulating a bronze coated wire helix. 100 0,320 0,008 10 000 +3000
125 0,399 0,013 10 000 +3000
7 Applications 150 0,478 0,018 10 000 +3000
Ideal for low to high pressure air conditioning and ventilation 160 0,509 0,021 10 000 +3000
systems. Suitable for use in general ventilation applications 180 0,565 0,025 10 000 +3000
including fresh air intake and exhaust, and kitchen and bath-
8 room.
200 0,638 0,032 10 000 +3000
250 0,798 0,051 10 000 +3000
300 0,958 0,073 10 000 +3000
Advantages
9 Encapsulated wire helix.
315 0,990 0,078 10 000 +3000
355 1,118 0,163 10 000 +3000
Smooth inner core.
Air tight. 400 1,275 0,129 10 000 +3000
10 High flexibility. 500 1,596 0,203 10 000 +3000
Durable materials.
Does not unravel when cut. Technical data
11 Keeps friction to a minimum. Duct materials...................... Two layers of 70 micron
Energy efficient. PVC encapsulating a fibre
Makes for easy installation. reinforcing bronze coated
Prevents tearing and puncturing. bead wire
12
Temperature range............... -30 to +80 C
Maximum air velocity........... 25 m/s
Packing ................................ Individual box
13
14
15
16 Ordering example
FD 162 10 000 PVC
Product
17 Dimension d
Length l
Material
18
d
3
l 4
Description 6
Single-layer duct wall. d O A l
d d2/4 m
nom m m2 mm kg
Advantages 7
Small storage and transport volume. 80 0,251 0,005 5000 0,67
No toxic gases are emitted in case of fire. 100 0,314 0,008 5000 0,83
Tested on fire resistance. 125 0,393 0,012 5000 1,04 8
140 0,440 0,015 5000 1,17
Technical data 150 0,471 0,018 5000 1,25
Duct material ....................... Aluminium
Minimum bending radius..... 1d
160 0,503 0,020 5000 1,33 9
Maximum temperature ........ +200 C 180 0,565 0,025 5000 1,79
Fire resistance ..................... Not flammable in 200 0,628 0,031 5000 1,99
accordance with DIN 4102 224 0,704 0,039 5000 2,23
10
class A1
Standard length................... 5 m also available in 3 m 250 0,785 0,049 5000 2,49
280 0,880 0,062 5000 2,79 11
300 0,942 0,071 5000 2,99
315 0,990 0,078 5000 3,14
355 1,12 0,099 5000 3,54 12
400 1,26 0,126 5000 3,99
13
14
15
Ordering example 16
SRF1C 160 5000 A
Product
Dimension d
17
Length l
Material
18
d
3
4 l
6 Description
Single-layer duct wall d O A l Max.
d d2/4 pressure
Can also be used where a flexible duct of aluminium is not nom m m2 mm Pa
7 sufficient to meet fire regulations. 80 and 100 mm are 80 0,251 0,005 5000 +10 000
usually used in this field of application.
100 0,314 0,008 5000 +10 000
8 Advantages 125 0,393 0,012 5000 +8000
Small storage and transport volume. 140 0,471 0,018 5000 +8000
No toxic gases are emitted in case of fire. 150 0,471 0,018 5000 +7000
9 Tested on fire resistance. 160 0,503 0,020 5000 +7000
180 0,565 0,025 5000 +7000
Technical data 200 0,628 0,031 5000 +7000
10 Duct material ....................... Galvanized steel sheet
224 0,704 0,039 5000 +5000
Minimum bending radius..... 1d
Maximum temperature ........ +350 C 250 0,785 0,049 5000 +5000
Fire resistance ..................... Not flammable in
11 accordance with DIN 4102
class A1
12
13
14
15
16 Ordering example
SRFV 160 5000 GALV
Product
17 Dimension d
Length l
Material
18
d
3
l
4
Description 6
Multiple layer product made up of aluminium/PET laminate d O A l Max.
formed into a flexible duct supported by a bronze coated d d2/4 pressure
wire helix. nom m m2 mm Pa
80 0,251 0,005 10000 +3000
7
100 0,320 0,008 10000 +3000
Technical data 125 0,399 0,013 10000 +3000 8
Duct materials ..................... Aluminium/PET laminate 150 0,478 0,018 10000 +3000
Fire retardant adhesive 160 0,509 0,021 10000 +3000
Bronze coated bead wire 9
180 0,565 0,025 10000 +3000
Temperature range .............. -30 to +140C
Maximum air velocity .......... 30 m/s 200 0,638 0,032 10000 +3000
Packing ............................... Individual box 224 0,707 0,040 10000 +3000
250 0,798 0,051 10000 +3000
10
315 0,990 0,078 10000 +3000
400 1,28 0,129 10000 +3000 11
12
13
14
15
Ordering example 16
FLD 162 10000 AP
Product
Dimension d
17
Length l
Material
18
d
3
l
5 d O A l Max.
d d2/4 pressure
nom m m2 mm Pa
Description 80 0,251 0,005 10 000 +3000
6
Multiple layer product made up of aluminium/PET laminate 100 0,320 0,008 10 000 +3000
and metalized polyester formed into a flexible duct sup- 125 0,399 0,013 10 000 +3000
ported by a bronze coated wire helix plus black PVC outer 133 0,418 0,014 10 000 +3000
7 covering. 150 0,478 0,018 10 000 +3000
160 0,503 0,020 10 000 +3000
Applications
8 Ideal for low to high pressure air conditioning and ventilation
180 0,565 0,025 10 000 +3000
200 0,638 0,032 10 000 +3000
systems.
250 0,798 0,051 10 000 +3000
9 Advantages 315 0,990 0,078 10 000 +3000
355 1,12 0,100 10 000 +3000
Encapsulated wire helix.
Smooth inner core.
10 Air tight. Technical data
High flexibility. Duct materials...................... Aluminium/PET laminate 1
Durable materials, resists tearing and puncturing. layer
11 Does not unravel when cut. Metalized PET 1 layer
Keeps friction to a minimum. 70 micron black PVC DINP
Energy efficient. 1 layer
Makes for easy installation. Bronze coated bead wire
12 Maintains shape when extended. Temperature range............... -30 to +125 C
Maximum air velocity........... 30 m/s
Packing ................................ Individual box
13
14
15
16 Ordering example
FLDD 160 10000 APPV
Product
17 Dimension d
Length l
Material
18
di
d
3
l
d d1 O A l m 5
d d2/4
nom mm m m2 mm kg
Description 63 63 0,198 0,003 10000 1,10
6
Multiple layer product made up of a PVC coated aluminium 80 82 0,258 0,005 10000 1,60
into a flexible duct supported by a steel wire helix. 100 102 0,320 0,008 10000 1,90
125 127 0,399 0,013 10000 2,20 7
Applications 160 160 0,503 0,020 10000 3,00
Suitable for use in general ventilation applications including 200 203 0,638 0,032 10000 4,00
fresh air intake and exhaust, and kitchen and bathroom. 250 254 0,798 0,051 10000 5,40 8
315 318 0,999 0,079 10000 6,00
Technical data 400 408 1,282 0,131 10000 10,0
Duct materials ..................... Aluminium
PVC
500 510 1,602 0,204 10000 12,0 9
Steel wire helix
Temperature range .............. -30 to +140 C
Packing ............................... Individual box 10
11
12
13
14
15
Ordering example 16
COMDEC 160 10000
Product
Dimension d
17
Length l
18
d
3
4 l = 5000
6 Description
d O A Max. pres-
Double-layer duct wall.
d d2/4 sure m
nom m m2 Pa kg
7 Applications 63 0,198 0,003 3150 1,30
Suitable for mechanical air supply systems and air condi- 80 0,251 0,005 3150 1,70
tioning systems
100 0,314 0,008 3150 2,10
8 125 0,393 0,012 3150 2,60
Advantages
140 0,440 0,015 3150 2,90
Small storage and transport volume.
150 0,471 0,018 2500 3,10
9 160 0,503 0,020 2500 3,30
Technical data
180 0,565 0,025 2500 3,70
Duct material ....................... Aluminium + aluminium (AL)
Minimum bending radius..... 1d 200 0,628 0,031 2500 4,20
10 Maximum temperature ........ +200 C 224 0,704 0,039 2500 4,60
Fire resistance ..................... Not flammable in 250 0,785 0,049 2000 5,20
accordance with DIN 4102 280 0,880 0,062 2000 5,80
11 class A1
300 0,942 0,071 2000 6,30
Delivery length:
63315 ......................... Compressed to 1,2 m 315 0,990 0,078 2000 6,50
12 Standard length................... 5m
13
14
15
16 Ordering example
SRFC 160
Product code
17 Dimension d
18
d1
l
rm
Description
Flexible and spiral folded duct for connection of air termimal
unit to ventilation system.
The end studs are equipped with male connectors.
Achieves tightness class C.
Available in three nominal lengths, lmax: 500, 1000 and 1500 d1 lmin lmax rm m
mm. nom mm mm mm kg
Is delivered compressed, lmin. 80 170 500 88 0,39
The product is type approved according (according to 80 270 1000 88 0,48
Swedish regulation) to TG 1142: 80 460 1500 88 0,61
100 170 500 110 0,50
Reaction to fire, class A1
Tightness class C 100 270 1000 110 0,61
100 460 1500 110 0,79
Advantages 125 170 500 138 0,60
Rapid installation. 125 270 1000 138 0,76
Small storage and transportation volyme. 125 460 1500 138 0,95
160 170 500 176 0,77
Technical data 160 270 1000 176 1,00
Duct material ............................. Aluminium 160 460 1500 176 1,24
End stud material ...................... Galvanized steel sheet 200 170 500 260 0,96
metal 200 270 1000 260 1,26
Max. temperature ...................... 200 C
200 460 1500 260 1,58
Specific pressure drop, straight duct 250 180 500 325 1,36
250 280 1000 325 1,68
d1
250 460 1500 325 2,03
80 100 125 160 200 250 315
20
315 180 500 408 1,73
10 315 320 1000 408 2,38
315 460 1500 408 2,67
pt [Pa/m]
5 10
2 v [m/s]
5
1
4
0,5 1,5 3
2
5 10 20 50 100 200 500 1000 2000 5000 10000 [l/s] Ordering example
20 50 100 200 500 1000 2000 5000 10000 20000 [m3/h] DRATU 125 500
q
Product
Dimension d1
Length lmax
d
l
Description
rm
Flexible and spiral folded duct for connection of air termimal
unit to ventilation system.
The end studs are equipped with female connectors.
Achieves tightness class C.
Available in three nominal lengths, lmax: 500, 1000 and 1500 d lmin lmax rm m
mm. nom mm mm mm kg
Is delivered compressed, lmin.
80 250 500 88 0,39
The product is type approved according (according to 80 350 1000 88 0,48
Swedish regulation) to TG 1142: 80 550 1500 88 0,61
Reaction to fire, class A1 100 250 500 110 0,50
Tightness class C 100 350 1000 110 0,61
100 550 1500 110 0,79
Advantages 125 250 500 138 0,60
Rapid installation. 125 350 1000 138 0,76
Small storage and transportation volyme. 125 550 1500 138 0,95
160 250 500 176 0,77
Technical data 160 350 1000 176 1,00
Duct material ............................. Aluminium 160 550 1500 176 1,24
End stud material ...................... Galvanized steel sheet
200 250 500 260 0,96
metal
Maximum temperature .............. 200 C 200 350 1000 260 1,26
200 550 1500 260 1,58
Specific pressure drop, straight duct 250 280 500 325 1,36
250 380 1000 325 1,68
d
80 100 125 160 200 250 315 250 550 1500 325 2,03
20
315 280 500 408 1,73
10
315 420 1000 408 2,38
pt [Pa/m]
2 v [m/s]
5
1
4
0,5 1,5 3
2
5 10 20 50 100 200 500 1000 2000 5000 10000 [l/s] Ordering example
20 50 100 200 500 1000 2000 5000 10000 20000 [m3/h] DRATMF 125 500
q
Product
Dimension d
Length lmax
d
l
rm
Description
Flexible and spiral folded duct for connection of air termimal
unit to ventilation system.
One end stud is equipped with a male connector, the other
with a female.
Achieves tightness class C. d lmin lmax rm m
Available in three nominal lengths, lmax: 500, 1000 and 1500 nom mm mm mm kg
mm. 80 210 500 88 0,39
Is delivered compressed, lmin.
80 310 1000 88 0,48
The product is type approved according (according to 80 500 1500 88 0,61
Swedish regulation) to TG 1142: 100 210 500 110 0,50
Reaction to fire, class A1 100 310 1000 110 0,61
Tightness class C 100 500 1500 110 0,79
125 210 500 138 0,60
Advantages 125 310 1000 138 0,76
Rapid installation. 125 500 1500 138 0,95
Small storage and transportation volyme. 160 210 500 176 0,77
160 310 1000 176 1,00
Technical data 160 500 1500 176 1,24
Duct material ............................. Aluminium 200 210 500 260 0,96
End stud material ...................... Galvanized steel sheet 200 310 1000 260 1,26
metal
200 500 1500 260 1,58
Max. temperature ...................... 200 C
250 220 500 325 1,36
Specific pressure drop, straight duct 250 320 1000 325 1,68
250 500 1500 325 2,03
d
80 100 125 160 200 250 315
315 220 500 408 1,73
20
315 360 1000 408 2,38
10
315 500 1500 408 2,67
pt [Pa/m]
5 10
2 v [m/s]
5
1
4
0,5 3
1,5 2 Ordering example
5 10 20 50 100 200 500 1000 2000 5000 10000 [l/s] DRATMFU 125 500
20 50 100 200 500 1000 2000 5000 10000 20000 [m3/h] Product
q
Dimension d
Length lmax
d
3
4 l
6 Description
Multiple layer inner core insulated with fibreglass, covered d O A l Max.
by a multiple layer outer jacket. d d2/4 pressure
nom m m2 mm Pa
7 80 0,251 0,005 10000 +3000
Technical data
Duct materials: 100 0,320 0,008 10000 +3000
8 inner wall (core)................ Multiple layers aluminium/ 125 0,399 0,013 10000 +3000
polyester supported by a 150 0,478 0,018 10000 +3000
bronze coated wire helix 160 0,509 0,015 10000 +3000
9 insulation.......................... 25 mm fibreglass
180 0,565 0,025 10000 +3000
outer wall (jacket) ............. Multiple layers aluminium/
polyester 200 0,638 0,032 10000 +3000
Temperature range .............. -30 to +125 C 315 0,990 0,078 10000 +3000
10 Standard length................... 10 m, other lengths on
request
Packing ............................... Individual box 1 m
11
12
13
14
15
16 Ordering example
FIBLD 160 10000 AP
Product
17 Dimension d
Length l
Material
18
d
3
l 4
Description 6
Double-layer inner duct wall. The inner duct wall is covered d O A l
with a fibre glass insulation. The insulation is covered with a d d2/4
double-layer outer duct. nom m m2 mm
80 0,251 0,005 3000
7
The insulation reduces the heat gain or loss resulting from a
temperature difference between the air flowing in the duct 100 0,314 0,008 3000
and the surrounding air. 125 0,393 0,012 3000 8
The outer duct acts as a vapour barrier to prevent conden- 140 0,440 0,015 3000
sation to enter into the insulation. Condensation can occur 150 0,471 0,018 3000
on the outside of a duct carrying air at lower temperatures 160 0,503 0,020 3000 9
than the surrounding air.
180 0,565 0,025 3000
15
Ordering example 16
SRFW 160 3000 50
Product
Dimension d
17
Length l
Thickness
18
d
3
4 l
6 Description
Multiple layer Al/PET sleeve encapsulating fiber glass insu- d O A l Max.
lation with inner PE sleeve. d d2/4 pressure
nom m m2 mm Pa
7 80 0,251 0,005 10000 +3000
100 0,320 0,008 10000 +3000
Technical data
8 Duct materials: 125 0,393 0,012 10000 +3000
inner wall (core)................ PE 160 0,503 0,020 10000 +3000
insulation.......................... 25/50 mm fibreglass 200 0,628 0,031 10000 +3000
9 outer wall (jacket) ............. Multiple layers aluminium/
250 0,785 0,049 10000 +3000
polyester
Temperature range .............. -30 to +125 C
Packing ............................... Rolled and strapped
10
11
12
13
14
15
16 Ordering example
FDFI 160 10000 AP
Product
17 Dimension d
Length l
Material
18
d
3
l 4
Description 6
d l
Fibre glass insulation. The insulation is covered with an
nom mm
outer jacket.
100 5000
125 5000 7
Applications
160 5000
The purpose is to insulate a rigid duct.
200 5000
The insulation reduces the heat gain or loss resulting from a 250 5000
8
temperature difference between the air flowing in a duct and
315 5000
the surrounding air.
The outer jacket acts as a vapour barrier to prevent conden- 9
sation to enter into the insulation. Condensation can occur
on the outside of a duct carrying air at lower temperatures
than the surrounding air. 10
Advantages
Easy assembly, saves installation time. 11
Very small storage and transport volume.
No toxic gases are emitted in case of fire.
Tested on fire resistance.
12
Technical data
Insulation materials:
insulation.......................... Glass wool 25 mm 13
outer wall (jacket) ............. Aluminium-polyester (AP)
Temperature range .............. -30 to +125 C
Delivery form ....................... Flattened 14
Packing ............................... Roll
Standard length................... 5m
15
Ordering example 16
FDI 160 5000 AP 25
Product
Dimension d
17
Length l
Material
Thickness
18
d
dy
3
4 l
5
Description Technical data
Inner duct wall of flexible, folded and perforated duct. The in- Duct material:
6 ner wall is covered with mineral wool insulation. The insula- inner wall (core).............. Perforated aluminium
tion is covered with an outer jacket. insulation........................ Mineral wool 25 mm
The insulation reduces the noise passing through the silenc- outer wall (jacket)........... Gray or white polyeten (PE)
7 er. For best attenuation the silencer shall be pulled out to full
length.
Specific pressure drop, straight silencer
8 Advantages d
80 100 125 160 200 250 315
Small storage and transport volume. 20
The ends are equipped with female connectors for simple
10
mounting and tighter connection.
9
pt [Pa/m]
2 v [m/s]
10 Ordering example 1
5
d1
dy
3
lmin
d1
5
Description d l dy lmin m 6
FSA is a flexible silencer with good sound attenuation. Inner mm mm mm mm kg
tube is flexible perforated aluminum with Acutec attenua- 100 1100 180 550 1
tion material (polyester). Outer tube is made of polyethylene. 125 1100 190 550 1,10
160 1100 220 550 1,30 7
Equipped with male connectors with Lindab Safe. 200 1100 260 550 1,70
250 1100 315 590 2,20
The sound leads through the casing and then attenuation
occurs. The bendability of the silencer allows adaption to
315 1100 380 590 2,60
8
very confined spaces and difficult wiring. For best attenua-
tion, the silencer must be pulled out to full length. Insertion loss
Delivered compressed, lmin. 9
Insertion loss [dB] for centre frequency [Hz]
d1
Effective attenuation mm 63 125 250 500 1k 2k 4k 8k
Attenuation material is Acutec (Polyester).
Easy to install
100
125
29
29
38
34
38
35
29
25
22
19
22
19
14
8
10
7
10
160 28 33 29 21 15 14 8 5
Tightness class C. 200 28 31 21 17 13 10 7 4
250 23 25 20 14 10 9 6 4 11
315 21 25 16 11 8 7 4 3
Technical data 12
pt [Pa/m]
100
d
13
0
15
10
1 [m
5
m]
12
50
0
16
10
20
0
25
s]
m/
5
31
v[
10
5
14
5 4
3
1
2 15
Order code 0.5
d1
dy
d
3
lmin
d
5
6 Description d l dy lmin m
FSAFU is a flexible silencer with good sound attenuation. mm mm mm mm kg
Inner tube is flexible perforated aluminum with Acutec 100 1120 180 550 1,00
attenuation material (polyester). Outer tube is made of poly- 125 1120 190 550 1,10
7 ethylene. 160 1120 220 550 1,30
200 1120 260 550 1,70
Equipped with one female connector and one male connec- 250 1140 315 590 2,20
12 Technical data
pt [Pa/m]
100
d
13
0
15
10
1 [m
5
m]
12
50
0
16
10
20
0
25
s]
m/
5
31
v[
14 10
5
5 4
3
15 1
2
1100 mm
d
3
l
4
5
d O A l Max.
d d2/4 pressure
Description nom m m2 mm Pa
6
Multiple layer acoustically perforated inner core covered 80 0,258 0,005 10000 +3000
with a PE sleeve, insulated with fibreglass, covered by a 100 0,320 0,008 10000 +3000
multiple layer outer jacket. 125 0,399 0,013 10000 +3000 7
150 0,478 0,018 10000 +3000
Applications 160 0,503 0,020 10000 +3000
Ideal for low, medium and high pressure heating, air condi-
tioning and ventilation systems.
180 0,565 0,025 10000 +3000 8
200 0,638 0,032 10000 +3000
224 0,719 0,041 10000 +3000
Advantages
Encapsulated wire helix.
250 0,798 0,051 10000 +3000 9
315 0,990 0,078 10000 +3000
Smooth inner core.
Air tight. 355 1,118 0,100 10000 +3000
High flexibility. 10
Durable materials. Technical data
Does not unravel when cut. Duct materials:
Keeps friction to a minimum. inner wall (core) ................ Multiple layers aluminium/ 11
Energy efficient. polyester supported by a
Makes for easy installation. bronze coated wire helix
Resists tearing and puncturing. insulation .......................... 25 mm fibreglass
outer wall (jacket) ............. Multiple layers aluminium/
12
polyester
Temperature range............... -30 to +125 C
13
14
15
Ordering example 16
FBLDFSL 160 10000 AP
Product
Dimension d
17
Length l
Material
18
dy
d1
2
l
3
Insertion loss [dB] for centre frequency
d1 [Hz]
nom l dy m
mm mm 63 125 250 500 1k 2k 4k 8k mm kg
4 80 750 135
80 1000 2 6 10 20 38 58 33 28 135 0,80
80 1250 135
5 80 1500 135
80 2000 135
100 750 160
100 1000 1 5 8 18 35 58 33 27 160 1,00
6 Description 100 1250 160
SLFA 25 is a flexible silencer that can be adapted to any 100 1500 160
installation situation. The bendability of the silencer allows 100 2000 160
adaptation to very confined spaces and difficult wiring. 125 750 190
7 Silencers are made from 2-layer, flexible aluminum tubes of 125 1000 1 5 8 18 35 58 33 27 190 1,20
type SRF. The inner tube is micro-perforated and between 125 1250 190
125 1500 190
the inner and outer tubes is a 25 mm thick attenuation mate-
8 rial layer of glass wool.
125
160
2000
750
190
210
The ends of the silencer are covered with aluminium gables. 160 1000 1 2 4 10 23 43 18 14 210 1,40
The duct connections fits inside ducts. 160 1250 210
9 SLFA 25 comes in the dimensions 80-315 mm and 1000 160 1500 210
mm in length. 160 2000 210
(Also available in lengths of 750, 1250, 1500 and 2000 mm). 200 750 260
The silencers can withstand temperatures up to 200 oC. 200 1000 2 2 4 9 20 27 13 11 260 1,80
10 200 1250 260
200 1500 260
200 2000 260
Advantages 250 750 310
11 Small storage and transport volume. 250 1000 1 2 4 9 18 19 9 9 310 2,20
250 1250 310
250 1500 310
Technical data 250 2000 310
12 Duct materials: 315 750 365
Inner wall: Aluminium + aluminium (AL) 315 1000 1 2 3 5 11 13 7 8 365 2,80
Insulation: Glass wool 25 mm 315 1250 365
13 Outer wall: Aluminium + aluminium 315 1500 365
315 2000 365
Minimum bending radius: 23d
Maximum temperature: +200 C
14 Fire resistance: Not flammable in accordance
with DIN 4102 class A1
15
dy
d1
2
l
3
Insertion loss [dB] for centre frequency
d1 [Hz]
nom l dy m
mm mm 63 125 250 500 1k 2k 4k 8k mm kg
80 750 190
4
80 1000 3 13 19 30 47 58 33 28 190 1,10
80 1250 190
80 1500 190 5
80 2000 190
100 750 210
100 1000 2 11 16 28 46 58 36 36 210 1,30
Description 100 1250 210 6
SLFA 50 is a flexible silencer that can be adapted to any 100 1500 210
installation situation. The bendability of the silencer allows 100 2000 210
adaptation to very confined spaces and difficult wiring. 125 750 235
Silencers are made from 2-layer, flexible aluminium tubes of 125 1000 1 7 13 24 41 45 29 28 235 1,70 7
type SRF. The inner tube is micro-perforated and between 125 1250 235
125 1500 235
the inner and outer tubes is a 50 mm thick attenuation mate-
rial layer of glass wool.
125
160
2000
750
235
260
8
The ends of the silencer are covered with aluminium gables. 160 1000 1 5 10 21 39 30 20 18 260 1,90
The duct connections fits inside ducts. 160 1250 260
SLFA 50 comes in the dimensions 80-315 mm and 1000 160 1500 260 9
mm in length. 160 2000 260
(Also available in lengths of 750, 1250, 1500 and 2000 mm). 200 750 310
The silencers can withstand temperatures up to 200 oC. 200 1000 3 4 9 16 32 22 15 15 310 2,40
200 1250 310 10
200 1500 310
Advantages 200 2000 310
Small storage and transport volume. 250 750 365
250 1000 2 4 8 16 33 15 11 12 365 3,00 11
250 1250 365
Technical data 250 1500 365
Duct materials: 250 2000 365
Inner wall: Aluminium + aluminium (AL) 315 750 410
12
Insulation: Glass wool 50 mm 315 1000 2 3 6 12 25 11 8 11 410 3,40
Outer wall: Aluminium + aluminium 315 1250 410
15
6 Description
A metal clamp for all types of flexible ducting. The clamp
consists of the band FDB and the flip-up band lock FDBL.
7 This system allows an easy and quick application thanks to
the automatic locking that forms the right diameter of the
duct.
8
Advantages
Labour saving.
9 The band has lifted edges to avoid damage to the ducting.
Technical data
10 Band width .......................... 9 mm
Band and lock material ....... Stainless steel AISI 430
Screw material..................... Galvanized steel
Screw head ......................... Hex Head 7 mm A/F
11
12
13
14
15
16 Ordering example
MDC 135 SS
Product
17 Dimension d
Material
18
Description Description 6
A metal band for all types of flexible ducting. The band lock A flip-up lock for the flexible duct band FDB.
FDBL fits this band.
Technical data 7
Advantages Lock material ....................... Stainless (SS) steel UNI X 8
The band has lifted edges to avoid damage to the ducting. CR17 - DIN 14010 (W2) -
Just cut to adequate length to fit any diameter. AISI 430 8
Screw material ..................... Galvanized steel
Technical data Screw head.......................... Hex Head 7 mm A/F
Diameter range.................... Any Packing ................................ Box of 50 pieces
Band width .......................... 9 mm
9
Band material ...................... Stainless (SS) steel AISI 430
Band length ......................... 30 m
10
11
12
13
14
15
16
Ordering example Ordering example
FDB 30 000 SS FDBL SS
Product Product 17
Length Material
Material
18
4
A B A
Total
5
12
13
14
15
Ordering example
16 FVA 25 70 100 PU
Product
Length
17 Width A
Width B
Material
18
12
13