Você está na página 1de 3

MAIN GIRDER DESIGN

Test Load, P = 12000 kN

Girder Length, l = 12 m
w
Transfer box width, l1 = 0m
TRANSFER
UDL, w = P/l BOX
= 1000.00 kN/m
(l-l1)/2 l1 (l-l1)/2
Factored UDL, wu = 1.4 x w l
= 1400.00 kN/m

Ultimate Moment, Mu = 1/2 x wu x ((I-l1)/2)2


= 25200 kNm

Ultimate Shear, Vu = wu x (l-l1)/2


= 8400 kN

Section Properties : d = 800 mm bf


bf = 300 mm bp1
tw = 16 mm
tf = 30 mm tp1
tf
Sxx = 9120400 mm3
py = 250 MPa
tp1 = 40 mm tw
bp1 = 250 mm tp2 bp2 d
Sxp1 = 8400000 mm3
tp2 = 0 mm
bp2 = 0 mm
Sxp2 = 0 mm3
tf
Sx = Sxx + Sxp1 + Sxp2 tp1
= 17520400 mm3

Resistant Moment, MR = Sx py
= 4380.1 kNm

Number of beam required = MU/MR


= 5.75

Number of beam provided = 6 nos ------> OK

Check Shear Capacity

Shear Capacity = 0.6 x Py x (d x tw+(2 x bp2 x tp2))

Page 1 of 3
MAIN GIRDER DESIGN
= 1920.00 kN

Vmax = Vu / nos of beam

= 1400.00 kN -------> OK

Page 2 of 3
Page 3 of 3