Você está na página 1de 20

Certofix Central Venous Catheter Sets

Uncompromising Quality for Safe Infusion Therapy

Central Venous Catheters


Certofix
... devices for safe and successful central venous catheter placement

Certofix central venous catheters from B. Braun combine out- Kink-proof guide wire
standing manufacturing quality with individual components that Highly flexible and resilient guide wire made

truly meet users needs. Sharing Expertise with our customers has out of Nitinol, with length markings
enabled us to develop each component according to the exacting Flexibility without compromising stability. The guide wire

requirements of real clinical practice. can be easily advanced even through venous obstructions
J and straight tip combined in one guide wire, depending

MORE CERTAINTY, MORE SAFETY, MORE SUCCESS on which end you use

Valve needle (V)

Seldinger needle (S)


J tip & Soft tip

Puncture needle Safsite valve Soft tip / J tip


Easy cannulation of the vein either Simplifies the daily changing of the The special tip material (PUR) is more
with standard Seldinger needle (S) infusion system on central venous pliant and softer than the catheter body
or with Valve needle (V) catheters and improves hygiene Protection of the intima in case

Quick, blood-free introduction of The air-tight valve guarantees a closed of contact with the vessel wall
the guide wire via the side port adapter system with every disconnection of Optimal surface with exceptional

of the valve needle syringe or infusion line to avoid air gliding features
Smart geometry for easy handling embolism
independent of chosen puncture Allows infusion and blood withdrawal

needle without flow restriction

2
Puncturing with ultrasound Puncturing with direct visual control
Ultrasound application for positioning of intravenous catheters The Certofix Seldinger needle and anatomical structure
is recommended in international guidelines. It enhances safety have good visibility using either the out-of-plane (transversal)
in anatomical investigation and puncturing. When using the and the in-plane (sagittal) method.
ultrasound probe, sterility and the correct dimensions of the
equipment are important factors.

ECG-lead technique
1 Enables immediate corrective measures,

if the initial positioning of the catheter


2 tip was too deep
Helps to prevent subsequent complications,

1 2 particularly the risk of pericardial perforation

3
Certofix

Broad range of choices for any application


B. Braun offers a comprehensive portfolio of central venous catheter
sets. From single lumen catheters for short term intervention to
quintuple lumen catheters in the intensive care unit
B. Braun provides solutions for all application areas. Different
catheter geometries enable the infusion of drugs and solutions at
any desired flow rate.

Mono Duo Trio Quattro

proximal

proximal
middle 2
proximal middle
middle 1
distal distal distal distal

User benefits Product specifications


Safe and accurate positioning
Main components
- kink-proof guide wire - Certofix central venous catheter with side clamps
- real-time ECG-lead position verification - kink-proof guide wire with soft J tip and
CVC insertion the safety approach
straight tip on dispenser
- Safsite valves - radio-opaque polyurethane catheter with
- clear connection lines - introducer needle (either Seldinger or
- kink-resistant catheter material valve needle)
- atraumatic catheter soft tip - ECG lead cable
Avoid drug incompatibility
- dilator
- multi-lumen catheters up to 5 connection lines

4
Certofix Highflow

Special solutions for volume-intensive infusion therapy


The large-sized channels are designed for high-volume
fluid substitution in short periods as well as veno-venous
acute dialysis.

Quinto Duo / Trio

proximal proximal

middle 3
middle 2
middle
middle 1
distal distal

Product specifications User benefits


Radio-opaque polyurethane catheter with

12F catheter ensures required stability without

- soft tip compromising flexibility


- length markings
Additional fixation wing at the point of channel

- junction hub for stitch fixation
- transparent extension lines separation, provides additional stability
- color-coded hub For acute dialysis (double opening, proximal

- white slide clamps lumen), and high flow rates


Accessories depending on set configuration

Also available with non-leaching antimicrobial

- movable fixation wing with clamp surface to protect against catheter-associated
- scalpel infections Certofix protect
- Safsite valve
- 5 ml Omnifix luer lock syringe
5
Certofix Mono

Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/ ECG-Cable Valve /
(REF) G (ml/min) * (cm) Length Seldinger needle Plug
Material
(cm)
Mono S 215 4160185 18 D 23 15 50 Steel Seldinger needle n -

Mono S 315 4160223 16 D 60 15 50 Steel Seldinger needle n -

Mono V 315 4160231 16 D 60 15 50 Steel Valve needle n -

Mono S 415 4160509 14 D 90 15 50 Steel Seldinger needle n -

Mono V 415 4160517 14 D 90 15 50 Steel Valve needle n -

Mono S 220 4160207 18 D 18 20 50 Steel Seldinger needle n -

Mono V 220 4160215 18 D 18 20 50 Steel Valve needle n -

Mono S 320 4160258 16 D 52 20 50 Steel Seldinger needle n -

Mono V 320 4160266 16 D 52 20 50 Steel Valve needle n -

Mono SN 320 4160258N 16 D 52 20 50 Nitinol Seldinger needle n -

Mono VN 320 4160266N 16 D 52 20 50 Nitinol Valve needle n -

Mono S 420 4160304 14 D 80 20 50 Steel Seldinger needle n -

Mono V 420 4160320 14 D 80 20 50 Steel Valve needle n -

Mono SN 420 4160304N 14 D 80 20 50 Nitinol Seldinger needle n -

Mono VN 420 4160320N 14 D 80 20 50 Nitinol Valve needle n -

Mono S 330 4160282 16 D 40 30 70 Steel Seldinger needle n -

Mono V 330 4160290 16 D 40 30 70 Steel Valve needle n -

Mono SN 330 4160282N 16 D 40 30 70 Nitinol Seldinger needle n -

Mono VN 330 4160290N 16 D 40 30 70 Nitinol Valve needle n -

Mono S 430 4160762 14 D 75 30 70 Steel Seldinger needle n -

Mono V 430 4160789 14 D 75 30 70 Steel Valve needle n -

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Additional information:
n The sales unit of Certofix Mono Sets is 10 pieces

n All catheters are made of PUR

6
Certofix Duo / Certofix Trio

Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/ ECG- Mini Valve /
(REF) G (ml/min) * (cm) Length Seldinger needle Cable Scalpel Plug
Material
(cm)
Duo S 715 4164158 16/16 D 60; P 50 15 50 Nitinol Seldinger needle n n Safsite valve

Duo V 715 4166159 16/16 D 60; P 50 15 50 Nitinol Valve needle n n Safsite valve

Duo S 720 4167385 16/16 D 55; P 45 20 50 Nitinol Seldinger needle n n Safsite valve

Duo V 720 4161211 16/16 D 55; P 45 20 50 Nitinol Valve needle n n Safsite valve

Duo S 730 4167394 16/16 D 52; P 37 30 70 Nitinol Seldinger needle n n Safsite valve

Duo V 730 4161319 16/16 D 52; P 37 30 70 Nitinol Valve needle n n Safsite valve

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/ ECG- Mini Valve /
(REF) G (ml/min) * (cm) Length Seldinger needle Cable Scalpel Plug
Material
(cm)
Trio S 715 4161159 16/18/18 D 50; M1 28; P 28 15 50 Nitinol Seldinger needle n n Safsite valve

Trio V 715 4162153 16/18/18 D 50; M1 28; P 28 15 50 Nitinol Valve needle n n Safsite valve

Trio S 720 4167408 16/18/18 D 46; M1 22; P 22 20 50 Nitinol Seldinger needle n n Safsite valve

Trio V 720 4163214 16/18/18 D 46; M1 22; P 22 20 50 Nitinol Valve needle n n Safsite valve

Trio S 730 4163306 16/18/18 D 38; M1 18; P 18 30 70 Nitinol Seldinger needle n n Safsite valve

Trio V 730 4163311 16/18/18 D 38; M1 18; P 18 30 70 Nitinol Valve needle n n Safsite valve

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Additional information:
n The sales unit of Certofix Duo and Trio Sets is 10 pieces

n All catheters are made of PUR

7
Certofix Quattro / Certofix Quinto

Product Type Code No. Cath. Lumen G Flow rate Length Guide wire Valve needle/
(REF) (ml/min) * (cm) Length (cm) Seldinger needle

Quattro V 815 4167767 14/18/18/16 D 50; M1 20; M2 20; P 50 15 50 Valve needle

Quattro V 820 4167775 14/18/18/16 D 40; M1 15; M2 15; P 40 20 50 Valve needle

Quattro V 830 4167783 14/18/18/16 D 35; M1 10; M2 10; P 35 30 70 Valve needle

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/
(REF) G (ml/min) * (cm) Length (cm) Seldinger needle

Quinto V 1215 4166841 16/18/18/18/12 D 65; M1 32; M2 32; M3 30; P 225 15 50 Valve needle

Quinto S 1220 4166852 16/18/18/18/12 D 55; M1 28; M2 28; M3 28; P 185 20 50 Seldinger needle

Quinto V 1220 4166868 16/18/18/18/12 D 55; M1 28; M2 28; M3 28; P 185 20 50 Valve needle

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

8
Certofix Highflow

Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/
(REF) G (ml/min) * (cm) length (cm) Seldinger needle

Duo HF V 715 4168518 14/18 D 105; P 42 15 50 Valve needle

Duo HF V 1215 4167538 11/11 D 260; P 260 15 50 Valve needle

Duo HF S 720 4168528 14/18 D 100; P 27 20 50 Seldinger needle

Duo HF V 720 4168534 14/18 D 100; P 27 20 50 Valve needle

Duo HF V 920 4167511 13/13 D 95; P 120 20 50 Valve needle

Duo HF V 1220 4167546 11/11 D 230; P 230 20 50 Valve needle

Trio HF S 1215 4160578 16/12/12 D 65; M1 225; P 225 15 50 Seldinger needle

Trio HF V 1215 4160614 16/12/12 D 65; M1 225; P 225 15 50 Valve needle

Trio HF S 1220 4160586 16/12/12 D 55; M1 165; P 165 20 50 Seldinger needle

Trio HF V 1220 4160622 16/12/12 D 55; M1 165; P 165 20 50 Valve needle

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Additional information:
n The sales unit of Certofix Highflow Sets is 10 pieces

n All catheters are made of PUR

9
Certofix Econoline

CVCs for your basic needs


Certofix Econoline catheters combine high quality with the key
components valued by users. All components included in the
Certofix Econoline sets such as the dilator, the Seldinger guide-
wire and the catheter itself are designed for reliable and safe
performance.

Mono Duo Trio IN-Stopper


B. Braun IN-Stoppers are
easy and convenient in
handling, provide closed
proximal needle-free injection sites
and offer a needle access
middle
via the integrated latex-free
proximal
membrane.
distal distal distal

User benefits Product specifications


Soft catheter material avoids venous irritations
Radio-opaque polyurethane catheter with
CVC insertion the safety approach
- soft tip
- IN-Stoppers - length markings
- kink-resistant catheter material - either with movable fixation device or junction
hub for stitch fixation
- catheter soft tip
- transparent extension lines on multilumen
Prevent risk of drug incompatibility

catheters
- multi-lumen catheters for up to 3 connection - color-coded hub
lines - white slide clamps
Rigid packaging for fast preparation and

convenient storage

10
Certofix Econoline

Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/ ECG- Valve /
(REF) G (ml/min) * (cm) Length Seldinger needle Cable Plug
Material
(cm)
Mono 215 Econoline 4160185E 18 D 16 15 50 Steel Seldinger needle - IN-Stopper

Mono 315 Econoline 4160223E 16 D 55 15 50 Steel Seldinger needle - IN-Stopper

Mono 415 Econoline 4160509E 14 D 95 15 50 Steel Seldinger needle - IN-Stopper

Mono 220 Econoline 4160207E 18 D 13 20 50 Steel Seldinger needle - IN-Stopper

Mono 320 Econoline 4160258E 16 D 45 20 50 Steel Seldinger needle - IN-Stopper

Mono 420 Econoline 4160304E 14 D 85 20 50 Steel Seldinger needle - IN-Stopper

Mono 330 Econoline 4160282E 16 D 40 30 70 Steel Seldinger needle - IN-Stopper

Mono 430 Econoline 4160762E 14 D 75 30 70 Steel Seldinger needle - IN-Stopper

Duo 715 Econoline 4164156E 16/16 D 60; P 50 15 50 Steel Seldinger needle - IN-Stopper

Duo 720 Econoline 4162200E 16/16 D 55; P 45 20 50 Steel Seldinger needle - IN-Stopper

Duo 730 Econoline 4162307E 16/16 D 52; P 37 20 70 Steel Seldinger needle - IN-Stopper

Trio 715 Econoline 4161157E 16/18/18 D 50; M1 28; P 28 15 50 Steel Seldinger needle - IN-Stopper

Trio 720 Econoline 4163206E 16/18/18 D 46; M1 22; P 22 20 50 Steel Seldinger needle - IN-Stopper

Trio 730 Econoline 4163303E 16/18/18 D 38; M1 18; P 18 30 70 Steel Seldinger needle - IN-Stopper

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Additional information:
n The sales unit of Certofix Econoline Sets is 10 pieces

n All catheters are made of PUR

Product specifications
Main components

- Certofix central venous catheter with side


clamps
- steel guide wire with J tip on dispenser
- Seldinger introducer needle
- dilator
- IN-Stopper
Accessories depending on set configuration

- movable fixation wing with clamp

11
Certofix

Anti-pathogenic Certofix protect catheters The functional principle of Certofix protect


The patented combination of an antimicrobial agent (poly- The polarization of the Certofix protect catheter material
hexanide) and an athrombogenic chemical group (polyethylene destroys the cell wall structure of microorganisms in the event
glycol and polymethacrylate) creates a catheter surface with ex- of surface contact. Ongoing chemical interaction between the
cellent anti-pathogenic characteristics. catheter material (PUR) and a biguanide agent ensures long-
The adhesion of bacteria, which is normally the starting point term protection without leaching effect. Certofix protect
of a catheter-related bloodstream infection, is effectively pre- prevents catheter-related infections during the entire
vented. In addition, a high concentration of hydrophilic groups application period.
lowers the risk of thrombus aggregation on the catheter surface.

Interaction of a
microorganism with
the catheter surface

Ecacy spectrum
Gram-positive bacteria (St. aureus, St. epidermidis)

MRSA (methicillin-resistant Staphylococcus aureus)

Gram-negative bacteria, e. g. Pseudimonas aeruginosa, Escherichia coli


coated vs. control (%)
Antibacterial efficiacy

Days

Long-term protection
Even after weeks, the Certofix protect catheter material exhibits an
effective level of protection against catheter colonization. After 30 days,
Certofix protect still shows an ecacy of 75 %.

User benefits Product specifications


Non-leaching no active agents are released,
Main components
thereby avoiding adverse systemic reactions - Certofix protect central venous catheter
Hydrophilic catheter surface for proven
with side clamps
reduction in thrombosis formation - kink-proof guide wire with soft J tip and
straight tip on dispenser
The same excellent flexibility as all

- valve needle
Certofix catheters - ECG lead cable
Complete catheter surface coverage
- dilator
from tip to hub on the inner surface, from tip to - 5 ml Omnifix luer lock syringe
channel junction on the outer surface

12
Product Type Code No. Cath. Lumen Flow rate Length Guide wire Mini Valve /
(REF) G (ml/min) * (cm) Length (cm) Scalpel Plug

Mono V 320 Protect 4160266P 16 D 52 20 50 - -

Mono V 420 Protect 4160320P 14 D 80 20 50 - -

Mono V 330 Protect 4160290P 16 D 40 30 70 - -

Mono V 430 Protect 4160789P 14 D 75 30 70 - -

Duo V 715 Protect 4166159P 16/16 D 60; P 50 15 50 n Safsite Valve

Duo V 720 Protect 4161211P 16/16 D 55; P 45 20 50 n Safsite Valve

Duo V 730 Protect 4161319P 16/16 D 52; P 37 30 70 n Safsite Valve

Duo HF V 720 Protect 4168534P 14/18 D 100; P 27 20 50 n Safsite Valve

Trio V 715 Protect 4162153P 16/18/18 D 50; M1 28; P 28 15 50 n Safsite Valve

Trio V 720 Protect 4163214P 16/18/18 D 46; M1 22; P 22 20 50 n Safsite Valve

Trio V 730 Protect 4163311P 16/18/18 D 38; M1 18; P 18 30 70 n Safsite Valve

Trio HF V 1220 Protect 4160622P 16/12/12 D 55; M1 165; P 165 20 50 n Safsite Valve

Quattro V 815 Protect 4167767P 14/18/18/16 D 50; M1 20; M2 20; P 50 15 50 n Safsite Valve

Quattro V 820 Protect 4167775P 14/18/18/16 D 40; M1 15; M2 15; P 40 20 50 n Safsite Valve

Quattro V 830 Protect 4167783P 14/18/18/16 D 35; M1 10; M2 10; P 35 30 70 n Safsite Valve

Quinto V 1220 Protect 4166868P 16/18/18/18/12 D 55; M1 28; M2 28; M3 28; P 185 20 50 n Safsite Valve

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

The base material of the central venous catheter Certofix protect is polyurethane (PUR). All lumens, including the hub and the outer
surface of the catheter, are embedded with a long-chain polymer based on methacrylate. Catheter material, includes also hydrophilic
side groups such as polyethylene glycol and antiseptic polymeric biguanide.

Additional information:
n The sales unit of Certofix protect Sets is 10 pieces

n All catheters are made of PUR

Product specifications
Radio-opaque polyurethane catheter with

- soft tip
- length markings
- junction hub for stitch fixation
- transparent extension lines
- color-coded hub
- green slide clamps
Accessories depending on set configuration

- movable fixation wing with clamp


- scalpel
- Safsite valve

13
Certofix Paed
... for childrens safety

Customized for the little ones


B. Brauns long experience and global expertise in infusion
therapy are incorporated in its paediatric range of central venous
catheters. Uncompromising quality and state-of-the-art features
combine to meet the special requirements of infants and children.

User benefits Product specifications


Safe and effective positioning
Radio-opaque polyurethane catheter with

- kink-proof guide wire - soft tip


- real-time ECG-lead position verification - length markings
Gentle for sensitive patients

- junction hub for stitch fixation if required
- transparent extension lines
- Teddy Bear catheter fixation makes
- color-coded hub
stitching unnecessary
- white slide clamps
- kink-proof guide wire avoids any damage
Main components

of the intima
- Certofix central venous catheter with
side clamps
- kink-proof guide wire with soft J tip and
straight tip on dispenser
- Seldinger introducer needle
- ECG lead cable
- dilator
- scalpel
- soft, self-adhesive catheter fixation
Accessories depending on set configuration

- Safsite valve or Discofix three-way stopcock


- 3 or 5 ml Omnifix luer lock syringe
- infusion extension line with side clamp
(mono sets only)
- Safsite valve
- movable fixation wing with clamp
14
Kink-proof guide wire Teddy Bear fixation Introducer guide for guide wire
Highly flexible and resilient guide wire Safe and easy catheter fixation without stitching Improves threading of the J tip of the
made of Nitinol Soft on the skin of infants and children guide wire into the Seldinger needle
Guide wire with the just the right stiffness Gentle removal possible Allows dispenser-free advancing of the

for easy advancing guide wire through the introducer

Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve /
(REF) G (ml/min) * (cm) / Length (cm) Plug

Mono Paed S 110* 4160177 22 D 15 10 0,5/25

Duo Paed S 408 4166906 22/22 D 18; P 18 8 0,46/50 Safsite Valve

Duo Paed S 413 4166922 22/22 D 10; P 10 13 0,46/50 Safsite Valve

Duo Paed S 420 4166949 22/22 D 9; P 9 20 0,46/50 Safsite Valve

Duo Paed S 508 4167112 18/20 D 30; P 15 8 0,46/50 Safsite Valve

Duo Paed S 513 4167139 18/20 D 22; P 11 13 0,46/50 Safsite Valve

Duo Paed S 520 4167155 18/20 D 18; P 9 20 0,46/50 Safsite Valve

Trio Paed S 508 4167228 20/22/22 D 30; M1 15; P 15 8 0,46/50 Safsite Valve

Trio Paed S 513 4167244 20/22/22 D 29; M1 10; P 10 13 0,46/50 Safsite Valve

Trio Paed S 520 4167260 20/22/22 D 18; M1 6; P 6 20 0,46/50 Safsite Valve

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Additional information:
The sales unit of Certofix Paed Sets is 10 pieces

All catheters are made of PUR

15
Certofix Safety
Increased safety for users

A broad variety of puncture needles and scalpels for incisions The Seldinger puncture needle has an active safety mechanism.
are used. The operating space and sterility during catheter The safety clip surrounds the needle tip as soon as the needle is
application often complicates the immediate disposal of such withdrawn, so medical personnel are well protected during oper-
sharp instruments. ation and disposal.
With Certofix Safety, B. Braun is enhancing its product
portfolio for safe venous access.

During application, the plastic housing with safety clip is located next to
the needle hub. Once the guide wire has been placed in its desired position,
the safety clip, covered by the hub, has to be forwarded onto skin level.
While simultaneously activating the safety mechanism, the needle is
withdrawn with the index finger.

After the protective cover has been removed, the scalpel is moved forward
with the help of the green button until it snaps into place. After the incision
it can be pushed back.

User benefits
The design of safety mechanisms is not affecting

the application procedure of central venous


catheter placement
All components needed for safe catheter place-

ment a safety Seldinger needle and a safety


scalpel with sharps injury protection mechanisms

16
Seldinger Needle Safety
Puncture needle with active safety mechanism to protect
against needle stick injuries. The integrated clip does not affect
the puncturing procedure and can be activated single-handedly.

2 3

It is possible to activate the clip, while the cannula is guided over the guide wire. Once the needle has been completely pulled back behind the wire, the safety
When the tip of the needle is reached, the safety clip activates automatically clip envelops the tip irreversibly. The needle and the plastic hub can now be
and covers the needle tip completely. disposed of in the usual manner.

II III

Latching-mechanism
appears in the window.

Before the blade is finally secured, the scalpel can be held in a parking position Once the blade has been fully withdrawn to the end of the press-button function,
enabling it to be handed over to other medical personnel. the safety mechanism activates. The scalpel can now be safely discarded.

Safety Scalpel
Stable, easy-to-use safety scalpel with safety mechanism.

17
Certofix Safety

Product Type Code No. Cath. Lumen Flow rate Length Guide wire
(REF) G (ml/min) * (cm) Length (cm)

Mono S 320 Safety 4160258S 16 D 52 20 50

Mono S 330 Safety 4160282S 16 D 40 30 70

Duo S 720 Safety 4167385S 16/16 D 55; P 45 20 50

Duo S 730 Safety 4167394S 16/16 D 52; P 37 30 70

Trio S 720 Safety 4167408S 16/18/18 D 46; M1 22; P 22 20 50

Trio S 730 Safety 4163306S 16/18/18 D 38; M1 18; P 18 30 70

Quattro S 820 Safety 4167775S 14/18/18/16 D 40; M1 15; M2 15; P 40 20 50

Quinto S 1220 Safety 4166852S 16/18/18/18/12 D 55; M1 28; M2 28; M3 28; P 185 20 50

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Additional information: Product specifications


n The sales unit of Certofix Safety Sets is 10 pieces
Radio-opaque polyurethane catheter with

n All catheters are made of PUR
- soft tip
- length markings
- junction hub for stitch fixation
- transparent extension lines
- color-coded hub
- white slide clamps
Main components

- Certofix central venous catheter with


side clamps
- kink-proof guide wire with soft J tip and
straight tip on dispenser
- Safety Seldinger introducer needle
- Safety scalpel
- ECG lead cable
- dilator
- movable fixation wing with clamp
Accessories depending on set configuration

- Safsite valve
- 5 ml Omnifix luer lock syringe

18
Certofix Accessories

Product Type Code No. (REF) Description


Certodyn Universal Adapter 4150228 Electronic switch box (for adults)

Certodyn Universal Adapter Paed 4150724 Electronic switch box (for paediatrics)

Alphacard U1800401 Syringe with electrode cable to universal adapter

Certodyn Universal Adapter Certodyn Universal Adapter Paed Alphacard

19
B. Braun Melsungen AG | Hospital Care | 34209 Melsungen | Germany
Tel +49 5661 71-0 | www.bbraun.com Nr. 606 2225

Você também pode gostar