Solve the communication
challenges of the Smart Grid
IXXAT SG-gateways are designed to enable communication between industrial
automation systems and control systems for energy, water/wastewater, gas and
railway power networks. They can also be used for networking equipment within
these systems. The integrated Web-PLC enables the SG-gateway to be used as an
information bridge between two systems, or to execute simple automation functions,
e.g. preprocessing measured data or generating messages (status and alarm
messages, etc.).
Web PLC
Application
examples for the
SG gateway
In electricity networks
Smart Grid
IEC 60870
SNMP
IEC 61850
Networking within and with
Other Infrastructure networks switchgear and transformer
networks energy, gas, water, railway
stations
Networks for the
industrial automation Linking of power generators to
Virtual Power Plants
Connection of plants to
Demand Response systems
ing and hands over the data to Function Charts). The Web-PLC Connection between energy
a control center in pre-processed provides a graphical user interface producers and control systems
form. accessible via the integrated web Networking of different infra-
server and a standard browser. structure systems (energy/gas)
e.g. for Power2X applications
Configuration Device access is either possible
and integration within the local network or by us- In the area of rail power
ing a remote control interface via networks and transport
The IXXAT SG-gateway is pro- cable or 3G secured via Open- infrastructure
grammed using an easy to operate VPN.
and intuitive Web-PLC. All func- Networking of control and mo-
tions are implemented similar to For programming, both complex nitoring systems of railway and
the well-known CFCs (Continuous function blocks as well as simple transport infrastructure net-
functions are available for signal works (such as tunnel systems)
preprocessing (AND, OR, XOR, with the control center
FF, TIMER, COUNTER, COM-
PARE). Alarm functions via SMS
can also be easily implemented. In the area of water/
wastewater management
Diagnosis and network analyzer
Connection of automation
functions (generating pcap files)
components in water supply
are integrated.
networks to the control center
Sewer monitoring and control
IXXAT SG-gateway