Você está na página 1de 4

Ultrasonic Piezoelectric Transducer

1. OVERVIEW
As the signal generating unit of the ultrasonic cold water meter, the Ultrasonic Cold
Water Meter Body is used for supplying accurate, stable and continuous ultrasonic signals
to the meter circuit.
The Ultrasonic Cold Water Meter Body is designed for residential use and conforms
to the Urban Construction Industry Standard CJT434-2013 of The PRC, taking into
account the water metering needs of different regions. The built-in transducers feature
high sensitivity, stable performance, high reliability and low power consumption.

2. CONSTRUCTION AND PRINCIPLE


Mechanical construction:Constructed by a pair of ultrasonic flow sensors, a set of pipe
components and display housing
Measuring principle: Measurement may be performed based on the transit time method.
By measuring the difference in the downstream and upstream propagation time of
ultrasonic pulses, the flow rate of the water in the pipe can be calculated.

3. TECHNICAL DATA
1)Product Name:: HZ0016-000
2)Model No.: RC20/HZ-US0004-000-01
3). Electrical characteristics of the built-in sensors::
Test condition
Item Unit Standard
T=25

Thick Resonant frequency Fs KHz 97530 Agilent 4294A

Resonant impedanceR 110 Agilent 4294A

Static capacitanceC0 pF 115020% At 1000Hz/1V

4) Technical Parameter
Test condition
Item Unit Standard
T=25
1Vp-p / 20 Pulse, Interval
20ms at 1MHz
Received Signal Amplitude mV 350
1Vp-p / 20 Pulses Interval
20ms at 1MHz
A1/20151207 Remark: This specification is subject to change without prior notice 1/10
Maximum Input Voltage Vp-p 5 At 1MHz

Maximum Allowable Working Pressure MPa 1.6

Installation Length mm 130 Vernier Caliper

Connecting Thread G1 Thread Gauge

Operating Temperature 0.1+50


Storage Temperature -25+55
Pressure Loss KPa 40 Q=4.0m3/h,T30
Installation Position Inlet
Installation Mode Threaded connection

5. Appearance and dimensionsUnit: mm

1Appearance and dimensions

A1/20151207 Remark: This specification is subject to change without prior notice 2/10
2Commanded PCB dimension

3Exploded Drawing

Component 113

A1/20151207 Remark: This specification is subject to change without prior notice 3/10
6). Main Component and Name

No. Part No. and Name QTY


1 HS0016-000 Flow Tube with Transducers 1
2 HZ0004-04S Seal Component 2
3 Component 113 Screw 3
4 XH0007-03S Connection Component 1
5 XH0007-10S Housing 1
6 XH0007-09S Housing Cover 1

7). Note:
1. Storage Condition:-25 C+55 C
2.Please take Anti interference into consideration when designing driving circuit
3.Driving voltage is suggested to be lower than 5Vp-p
4. Maximum pressure endurance is 1.6MPa

8). Revision history:



File revision history

ECR

Revsion Version of The number of
Contents of revision
time revision ECR

2015/12/07 / /

/ /
Accomplished by/Date Approved by/Date

A1/20151207 Remark: This specification is subject to change without prior notice 4/10

Você também pode gostar