Você está na página 1de 2

-

SIZE DWG NO SH REV

8 7 6 5 4 3 D 108T8447 1 1 SYNERGY TOOL-V1.0

REVISION HISTORY
THIS DOCUMENT SHALL BE REVISED IN DATE
ITS ENTIRETY. ALL SHEETS OF THIS REV ZONE DESCRIPTION APPROVED
(YYYY-MM-DD)
NOTES: DOCUMENT ARE THE SAME REVISION
LEVEL AS INDICATED.
1. LINEAR DIMENSIONS IN BRACKETS [ ] ARE IN
MILLIMETERS AND ARE FOR REFERENCE ONLY.
ALL DIMENSIONS OF THE MANUFACTURED PART(S)
-
MUST EQUAL THE DECIMAL-INCH DIMENSIONS AND,
D WHEN REQUIRED, BE RECORDED IN DECIMAL-INCH REVISE ON CAD ONLY D
UNITS. MILLIMETERS DIMENSIONS SHOWN MAY NOT
CONVERT EXACTLY FROM INCHES DUE TO DIMENSIONAL NX PART: 108T8447
ROUNDING.
6 ELBOW
2. QUENCH RING VENDOR SCOPE OF SUPPLY SHALL BE THE
PARTS SHOWN IN THIS DRAWING, WHICH INCLUDE
THE HOTFACE (PART 1), PLUGS FOR INSPECTION HOLES (PART 11), PIPE 9
8 PIPE
QUENCH WATER ELBOWS (PART 6) AND FLANGES/HUBS (PART 7). 10

3. GASIFIER VENDOR SCOPE OF SUPPLY SHALL INCLUDE DIP TUBE PREPARED FOR WATER DISTRIBUTION
FIELD WELD TO QUENCH RING. CHANNEL
4. GASIFIER VENDOR SCOPE OF SUPPLY SHALL INCLUDE GASKET
AND BOLTS TO ATTACH QUENCH RING TO REFRACTORY SUPPORT
PLATE PER FOLLOWING REQUIREMENTS: FLANGE 7
a) 36-3/4" (19mm) ALLOY 825 STUDS.
b) USE ONE ACORN NUT (TACK WELD TO REFRACTORY SUPPORT PLATE),
ONE SPLIT RING LOCK WASHER AND ONE HEX NUT ON EACH SIDE PER STUD.
HARDWARE SHALL BE ALLOY 825. 11 INSPECTIN PLUG
c) GASKET - 1/8" (3.2mm) THICK FLEXIBLE GRAPHITE LAMINATE WITH FLAT 316 SS
INSERT, FLAT RING (UCAR GRAFOIL GRADE GHR OR EQUAL) 46.0" ID X 70.362" OD.
d) PUNCH GASKET WITH 40-0.906" HOLES AT 9 SPACING.
C 5. PART SHALL BE HARD FIXTURED INSPECTED IN A MINIMUM OF 8 PLACES FOR C
DIAMETER. THE AVERAGE DIAMETER IS STATED AS PRINT NOMINAL. INDIVIDUAL
LIMITS ARE STATED PER LOCATION. DIP TUBE 5
SKIRT
6. A SERIAL NUMBER WILL BE STAMPED AT 0 ON THE OD SURFACE
OF THE WATER DISTRIBUTION CHANNEL (PART 10).

BEARING BALL 3

HOTFACE 1
4 BOTTOM PLATE

-
B

REV

1
SH

108T8447
BAFFLE 2

C COPYRIGHT 2013 GE POWER & WATER (USA), LLC AND/OR ITS AFFILIATES.

SIZE DWG NO
All rights reserved. The information contained herein is GE Power & Water Gasification Proprietary Technical Information
that belongs to the General Electric Company, GE Power & Water (USA), LLC and/or their affiliates, which has been provided

D
solely for the express reason of restricted private use. All persons, firms, or corporations who receive such information
shall be deemed by the act of their receiving the same to have agreed to make no duplication, or other disclosure, or use
whatsoever for any, or all such information except as expressly authorized in writing by the General Electric Company,
GE Power & Water (USA), LLC and/or its affiliates.

GE CLASS III (CONFIDENTIAL)


UNLESS OTHERWISE SPECIFIED DWG TYPE
DIMENSIONS ARE IN INCHES [MM] OUTLINE
ANGLES GE POWER & WATER
DRAWN 204040026
2 PL DECIMALS GASIFICATION TECHNOLOGY
3 PL DECIMALS DRAWN DATE (YYYY-MM-DD) 2013-06-27
A ALL SURFACES CHECK 105039198 A
CHECK DATE (YYYY-MM-DD)
THIRD ANGLE PROJECTION
ENGRG 204051587
LAKE CHARLES
CLEAN ENERGY PROJECT
UNIVFRMT_D_SH1 (072011)

ENGRG DATE (YYYY-MM-DD)


ADDITIONAL APPROVALS
QUENCH RING OUTLINE
SEE PLM FOR FIRST MADE FOR
1980-2013- ( ) / . . APPROVAL INFORMATION
GE , , ( ) / , APPLIED PRACTICES FOR GE USE ONLY SIZE CAGE CODE DWG NO
THIS DRAWING PREPARED . , ( ) / , MLI/PBM CODE 274490

IN ACCORDANCE WITH
ASME Y14.5M-1994
, , . MATERIAL:
348A9200
DWG SOURCE
SIMILAR TO
NX7.5
D 108T8447
SCALE NONE REF WT SHEET
RDO CODE US-TX, HOUSTON
1507.7 LBS 1 OF 2
8 7 6 5 4 3 2 1
-
SIZE DWG NO SH REV

8 7 6 5 4 3 D 108T8447 2 1
REVISION HISTORY
DATE
REV ZONE DESCRIPTION APPROVED
(YYYY-MM-DD)

45

D REVISE ON CAD ONLY D


NX PART: 108T8447
0.060 0.010
0.250
1.52 0.25
+0.010
0 40X 0.906 THRU 6.35
-0.005
+0.25
DETAIL C
4.500 C 23.01
-0.13
EQUALLY SPACED
SEE NOTE 6
.040 [1.01] A B 70.362 B

1787.19

46.000
68.362
1736.39 1168.40

C 17.658 2.957 C

448,51 75,11 A

B
4X 15.757

A A 400,23

60

C 4X 32.332
13.061
821.24
331.75 B

-
B O.D. 51.000 .032

REV
1295,40 ,81

2
SH
SEE NOTE 5
(50.875 - 51.125)

108T8447
64.665
6X ASME B16.5 1642.48
150lb 6" SCH40
RFSO FLANGE
SS316L 74.128

SIZE DWG NO
.100 [2.51] A B C
1882.86

D
11.000
279.40
40X 0.906
8X 0.875 .080 [2.01] A B C
23.01 SECTION A-A
22.22
C COPYRIGHT 2013 GE POWER & WATER (USA), LLC AND/OR ITS AFFILIATES.

A
TOP VIEW All rights reserved. The information contained herein is GE Power & Water Gasification
Proprietary Technical Information that belongs to the General Electric Company,
A GE Power & Water (USA), LLC and/or their affiliates, which has been provided solely for the
express reason of restricted private use.All persons, firms, or corporations who receive
such information shall be deemed by the act of their receiving the same to have agreed
UNIVFRMT_C_CONT (072011)

to make no duplication, or other disclosure, or use whatsoever for any, or all such
information except as expressly authorized in writing by the General Electric Company,
GE Power & Water (USA), LLC and/or its affiliates.

DETAIL B GE POWER & WATER


GE CLASS III (CONFIDENTIAL)
SIZE CAGE CODE DWG NO
GASIFICATION TECHNOLOGY

DRAWN 204040026 DRAWN BY DATE


(YYYY-MM-DD)
D 108T8447
SCALE SHEET
ENGRG 105039198 2013-07-23 NONE 2 OF 2
8 7 6 5 4 3 2 1