Escolar Documentos
Profissional Documentos
Cultura Documentos
Refrigerator
SSEDA RS261*
- 1/47 -
SSEDA-PJT Repair Guide
[ RS261M* ]
Weak Cooling(F/R)
Cooling
Cooling Too Cold
- 2/47 -
Ice & Water
#1. Symptom : No Ice Repair Schematic
Lever S/W sensing Inspect LEVER S/W 1-2 Panel- Wire Ice
problem operation PBA Harness Bucket
Ice Bucket Inspect Bucket
ice exist assembly
(dispensing
Auger Motor S/W Inspect Auger Motor Auger Wire
problem)
defect S/W operation Motor Harness
S/W
Auger Motor failure Inspect ASSY AUGE 1-3 ASSY Wire Main
R-MOTOR operation Auger Harness PBA
Motor
- 3/47 -
Tip 1-1. Inspect Display Water & Ice selection
Step 1
Step 2
Step 3
If it is not solved
- Replace and repair MAIN PBA
- 4/47 -
Tip 1-2. Inspect Lever S/W & Auger Motor S/W operation
Step 1
Check the Auger motor rotation sound which
is inside of F room with pushing DISPENSER
LEVER.
- 5/47 -
Tip 1-3. Inspect ASSY Auger Motor operation
Step 1
Step 3
- 6/47 -
Tip 2-1. Inspect Water supply / supply
Need lever operation for 3 min on initial and after replace Filter !
Step 1
Inspect water comes when lever operation
after Water selection.
Initial product needs Water Tank filling time
- When the water does not come Check Step 2
- When the water comes Check TIP 2-4
Step 5
When the water comes well through water
line, check water pressure when use external
water filter.
- 7/47 -
Tip 2-2. Inspect Ice Valve operation
Step 1
CN 70 CN 73
- 8/47 -
Tip 2-3. Inspect ASSY PIPE-WATER (Heater) freezing
Step 1
Connector
Main PBA
CN 70,71
- 9/47 -
Tip 2-4. Inspect Self diagnosis test ( Must select Power Freeze first)
Fan motor Fan motor displays failure for
power on condition.
Touch Display Lighting+ Energy Saver Key for
8 sec at the same time.
- Press until all LED blink and dingdong sound
appears.
- No problem on self-diagnosischeck TIP 2-2
Display (Image) Failure Item Measure IMAGE
- 10/47 -
Tip 2-4-1. Inspect self-diagnosis test
Inspect Ice Maker
Block
Connector
- 11/47 -
Tip 2-4-2. Inspect self-diagnosis test
F Sensor / Cabinet Fan / Defrost Sensor / Defrost Error
Block
D-Sensor
F-Sensor
Fan Motor
- 12/47 -
Tip 2-4-3. Inspect self-diagnosis test
R Sensor / F Damper Motor
Block
R-Sensor
Damper
Damper
CN 70,71
CN 40
CN 76
CN 50
- 13/47 -
Tip 2-4-4. Inspect self-diagnosis test
External R Sensor / C-Fan Motor
Block
C-Fan
EXT-Sensor
CN 70,71
CN 40
CN 76
CN 50
- 14/47 -
Tip 2-5. Inspect cooling power ( Must select Power
Freeze first)
Do not off the power Measure self-diagnosis test on
TIP 2-4
Step 1
Press Display Lighting+ Energy Saver Key for
8sec at the same time.
- Press until all LEDs are Blinking and dingdong
sound appears
Relay
separation
Inspect
Connector
- 16/47 -
Ice & Water
#2. Symptom : No Water & other(LEAK) Repair distribution diagram
No Water WATER LEVER S/W Inspect LEVER S/W 3-3 LEVER DOOR WIRE
operation S/W S/W HARNES
S
Door S/W
- 17/47 -
Tip 3-1. Inspect WATER connection / supply
- 18/47 -
Tip 3-2. Inspect WATER VALVE operation
Step 1
Step 2
After disassemble ASSY Valve and check
WHITE 2-Wire
- Normal parts : 350~450
- Failure parts : Open or 0
CN 70
CN 73
- 19/47 -
Tip 3-3. Inspect WATER Lever S/W operation
Step 1
Step 2
MAGNET CHECK
Inspect F DOOR UPP MAGNET existence
Step 3
CN 50
- 20/47 -
Tip 3-4. Inspect WATER HOSE
Step 1
Step 2
Step 3
Check F-DOOR HINGE-LOW part WATER
HOSE bending.
- 21/47 -
Tip 4-1. Inspect WATER LINE LEAK
Step 1
Step 2
GOOD
Less
NG inserting
Step 3
- 22/47 -
Tip 4-2. Inspect WATER DISPENSER DRIPPING
Step 1
Step 2
Step 3
Inspect WATER TANK AIR
Step 5
Disassemble Water hose which is connected
to product.
Inspect bubble occurrence in the water when
BUBBLE
supply water to container.
- When BUBBLE appears it is not the
problem of the product.
Step 6
- Customer explanation
- 23/47 -
Tip 4-3. Inspect WATER HOSE NOISE
Step 1 HOSE
VIBRATION
Dispense water with pressing WATER LEVER.
Step 2
Step 3
Disassemble FILTER.
-After disassemble the FILTER and hose is
not shaken after dispensing WATER replace
FILTER CASE.
- 24/47 -
DEFROST
#1. Symptom : EVAP / ICE ROUTE DEFROST Repair
EVAP DEFROST Only the top of the 5-2 DEF-Sen HEATER Main
BUILD problem EVAP ice. sor PBA
EVAP
DEFROST Only the bottom of
BUILD the EVAP ice.
- 25/47 -
Tip 5-1. Self diagnosis test inspection ( Must select Power Freeze first)
- 26/47 -
Tip 5-1-1. Inspect self-diagnosis test
Inspect Ice Maker
Block
Connector
- Rotating operation:
CN 90 1(RED)=2(BLK)
- Output sensing: 5(BLU)
- Test input: 4(S/BLU)
- 27/47 -
Tip 5-1-2. Inspect self-diagnosis test
F Sensor / cabinet Fan / Defrost Sensor / Defrost Error
Block
D-Sensor
F-Sensor
Fan Motor
Defrost Error
: Inspect brown 2-Wire
CN 50
CN 75 connector
-Main PBA : CN70 No.5(BRN)
+ CN71 No.1(ORN)
- 28/47 -
Tip 5-1-3. Inspect self-diagnosis test
R Sensor / F Damper Motor
Block
R-Sensor
Damper
Damper
CN 70,71
CN 40
CN 76
CN 50
- 29/47 -
Tip 5-1-4. Inspect self-diagnosis test
External air R Sensor / C-Fan Motor
Block
C-Fan
EXT-Sensor
CN 70,71
CN 40
CN 76
CN 50
- 30/47 -
Tip 5-2. Inspect EVAP DEFROST BUILD
Do not off the power and operate self-diagnosis test on TIP 5-1
first.
Must check the forced defrost operation after defrosting repair.
Step 1
Step 3 HEATER
& BIMETAL
Measure BROWN WIRE resistance.
- Normal part : 35~60
- Failure part : Open or 0
Replace it because of HEATER &
BIMETAL OPEN failure
Step 4
Step 5
- 32/47 -
Tip 6-1. Inspect ICE ROUTE DEFROST BUILD
Step 1
Step 3
- 33/47 -
NOISE
#1. Symptom : Water Hose & UNIT NOISE Repair distribution diagram
Water
HOSE
NOISE
- 34/47 -
Tip 7-1. Inspect WATER HOSE NOISE
Step 1 HOSE
VIBRATION
Dispense water with pressing WATER LEVER.
Step 2
Step 3
Disassemble FILTER.
- Replace Filter case when the Hose does not
quake after disassemble FILTER and dispense
water.
- 35/47 -
Tip 8-1. Inspect UNIT NOISE
Step 1
Step 2
FAN + WIRE
PIPE + COVER
- 36/47 -
Tip 8-2. Inspect CYCLE NOISE
Step 1
Step 2
Inspect RUBBER
DRYER angle
- 37/47 -
COOLING
#1. Symptom : WEAK COOLING & TOO COLD Repair
Inspect R WEAK
COOLING
Measure cooling 9-2 Comp Cycle C-fan
power inspection Relay Shield
System
WEAK Inspect Comp / Fan
COOLING motor
- 38/47 -
Tip 9-1. Inspect self-diagnosis test ( Must select Power Freeze first)
Inspect disassembled
F Mid-Mid-Strong" C-FAN ERROR
machinery room COVER C-Fan
- 39/47 -
Tip 9-1-1. Inspect self-diagnosis test
Inspect Ice Maker
Block
Connector
- 40/47 -
Tip 9-1-2. Inspect self-diagnosis test
F Sensor / cabinet Fan / Defrost Sensor / Defrost Error
Block
D-Sensor
F-Sensor
Fan Motor
Defrost Error
CN 50
CN 75 : Inspect brown 2-Wire
connector
-Main PBA : CN70 No.5(BRN)
+ CN71 No.1(ORN)
- 41/47 -
Tip 9-1-3. Inspect self-diagnosis test
R Sensor / R Damper Motor
Block
R-Sensor
Damper
Damper
CN 70,71
CN 40
CN 76
CN 50
- 42/47 -
Tip 9-1-4. Inspect self-diagnosis test
External R Sensor / C-Fan Motor
Block
C-Fan
EXT-Sensor
CN 70,71
CN 40
CN 76
CN 50
- 43/47 -
Tip 9-2. Inspect cooling power ( Must select Power
Freeze first)
Do not off the power Measure self diagnosis test
inspection on TIP 9-1
Step 1
Press Display Lighting+ Energy Saver Key for 8
sec at the same time.
- Press until all LEDs are Blinking and DingDong
sound appear
Relay separation
Inspect
Connector
- 45/47 -
Tip 9-3. Inspect EVAP DEFROST BUILD
Do not off the power and operate self-diagnosis test toTIP 5-1
first.
Must check the forced defrost operation after defrost repairing.
Step 1
Step 3 HEATER
& BIMETAL
Measure BROWN WIRE resistance.
- Normal part : 35~60
- Failure part : Open or 0
Replace HEATER & BIMETAL OPEN
because it is failure.
Step 4
Step 5
- 47/47 -
Tip 10-1. Inspect R TOO COLD
Step 1
R-Sensor
Damper
Damper
Step 2
Inspect DAMPER
- Inspect Damper Closing condition when
disassemble
- 48/47 -