Glucose Tests
Also known as: Blood Sugar; Fasting Blood Sugar; FBS; Fasting Blood Glucose; FBG; Fasting Plasma Glucose; FPG; Blood Glucose; Oral Glucose
Tolerance Test; OGTT; GTT; Urine Glucose
Formal name: Blood Glucose; Urine Glucose
Related tests: A1c; Urinalysis; Insulin; C-peptide; Urine Albumin; Comprehensive Metabolic Panel; Basic Metabolic Panel; Fructosamine
All content on Lab Tests Online has been reviewed and approved by our Editorial Review Board.
At a Glance
Why Get Tested?
To determine if your blood glucose level is within a healthy range; to screen for and diagnose diabetes and prediabetes and to monitor for high blood glucose
(hyperglycemia) or low blood glucose (hypoglycemia); to check for glucose in your urine
Blood glucose: when you are older than 45 years or have risk factors for diabetes; when you have symptoms suggesting high or low blood glucose; during
pregnancy; when you are diabetic, self-checks up to several times a day to monitor blood glucose levels
Sample Required?
A blood sample drawn from a vein in your arm or a drop of blood from a skin prick; sometimes a random urine sample is used. Some diabetics may use a
continuous glucose monitor, which uses a small sensor wire inserted beneath the skin of the abdomen to measure blood glucose at frequent intervals and provides
a result.
In general, it is recommended that you fast (nothing to eat or drink except water) for at least 8 hours before having a blood glucose test. For people with diabetes,
glucose levels are often checked both while fasting and after meals to provide the best control of diabetes. For random, timed, and post-meal glucose tests, follow
your health practitioner's instructions.
Glucose is the primary energy source for the body's cells and the only energy source for the brain and nervous system. A steady supply must be available for use,
and a relatively constant level of glucose must be maintained in the blood. A few different protocols may be used to evaluate the glucose level in the blood. See
"How is it used?" for more information on these. Sometimes, glucose may be tested in urine.
During digestion, fruits, vegetables, breads and other dietary sources of carbohydrates are broken down into glucose (and other nutrients); they are absorbed by
the small intestine and circulated throughout the body. Using glucose for energy production depends on insulin, a hormone produced by the pancreas. Insulin
facilitates transport of glucose into the body's cells and directs the liver to store excess energy as glycogen for short-term storage and/or as triglycerides in adipose
(fat) cells.
Normally, blood glucose rises slightly after a meal and insulin is released by the pancreas into the blood in response, with the amount corresponding to the size and
content of the meal. As glucose moves into the cells and is metabolized, the level in the blood drops and the pancreas responds by slowing, then stopping the
release of insulin.
If the blood glucose level drops too low, such as might occur in between meals or after a strenuous workout, glucagon (another pancreatic hormone) is secreted to
induce the liver to turn some glycogen back into glucose, raising the blood glucose level. If the glucose/insulin feedback mechanism is working properly, the amount
of glucose in the blood remains fairly stable. If the balance is disrupted and the glucose level in the blood rises, then the body tries to restore the balance, both by
increasing insulin production and by eliminating excess glucose in the urine.
There are a few different conditions that may disrupt the balance between glucose and the pancreatic hormones, resulting in high or low blood glucose. The most
common cause is diabetes. Diabetes is a group of disorders associated with insufficient insulin production and/or a resistance to the effects of insulin. People with
untreated diabetes are not able to process and use glucose normally. Those who are not able to produce any or enough insulin (and typically have diabetes
autoantibodies) are diagnosed as having type 1 diabetes. Those who are resistant to insulin and may or may not be able to produce sufficient quantities of it may
have prediabetes or type 2 diabetes.
Severe, acute changes in blood glucose, either high (hyperglycemia) or low (hypoglycemia), can be life-threatening, causing organ failure, brain damage, coma,
and, in extreme cases, death. Chronically high blood glucose levels can cause progressive damage to body organs such as the kidneys, eyes, heart and blood
vessels, and nerves. Chronic hypoglycemia can lead to brain and nerve damage.
Some women may develop gestational diabetes, which is hyperglycemia that occurs only during pregnancy. If untreated, this can cause these mothers to give birth
to large babies who may have low glucose levels. Women who have had gestational diabetes may or may not go on to develop diabetes.
A blood sample is obtained by inserting a needle into a vein in the arm or a drop of blood is taken by pricking a finger with a small, pointed lancet (fingerstick).
Sometimes, a random urine sample is collected. Some diabetics may use a continuous glucose monitor, which uses a small sensor wire inserted beneath the skin
of the abdomen and held in place with an adhesive patch. The sensor measures blood glucose levels at frequent intervals and sends the results to a device that is
attached to the person's clothing. A digital readout on the device lets the person know the blood glucose level in real time.
For screening purposes, fasting is generally recommended (nothing to eat or drink except water) for at least 8 hours before a blood glucose test. Those who have
been diagnosed with diabetes and are monitoring their glucose levels are often tested both while fasting and after meals. For random and timed tests, follow the
health practitioner's instructions. A glucose tolerance test requires that the person fast for the first blood sample and then drink a liquid containing a specified
amount of glucose; subsequent blood samples are drawn at specified times.
The Test
How is it used?
Detect high blood glucose (hyperglycemia) and low blood glucose (hypoglycemia)
Screen for diabetes in people who are at risk before signs and symptoms are apparent; in some cases, there may be no early signs or symptoms of diabetes.
Screening can therefore be useful in helping to identify it and allowing for treatment before the condition worsens or complications arise.
A few different testing protocols may be used to evaluate blood glucose levels, depending on the purpose.
Fasting glucose (fasting blood glucose, FBG) this test measures the level of glucose in the blood after fasting for at least 8 hours.
2-hour glucose tolerance test (GTT) for this test, the person has a fasting glucose test done (see above), then drinks a 75-gram glucose drink. Another blood
sample is drawn 2 hours after the glucose drink. This protocol "challenges" the person's body to process the glucose. Normally, the blood glucose level rises
after the drink and stimulates the pancreas to release insulin into the bloodstream. Insulin allows the glucose to be taken up by cells. As time passes, the blood
glucose level is expected to decrease again. When a person is unable to produce enough insulin, or if the body's cells are resistant to its effects (insulin
resistance), then less glucose is transported from the blood into cells and the blood glucose level remains high.
A different test called hemoglobin A1c may be used as an alternative to glucose testing for screening and diagnosis. (For more, see the article on A1c.).
Sometimes a blood sample may be drawn and glucose measured when a person has not been fasting, for example, when a comprehensive metabolic panel (CMP)
is performed. If the result is abnormal, it is typically followed up with a fasting blood glucose test or a GTT.
Glucose blood tests are also used to screen pregnant women for gestational diabetes between their 24th and 28th week of pregnancy. The American Diabetes
Association and the U.S. Preventive Services Task Force recommend that pregnant women not previously known to have diabetes be screened and diagnosed,
using either a one-step or two-step approach. The American College of Obstetricians and Gynecologists (ACOG) recommends the two-step approach.
One-step 2-hour oral glucose tolerance test (OGTT). After a fasting glucose level is measured, a woman is given a 75-gram dose of glucose to drink and her
glucose levels are measured at 1 hour and 2 hours after the dose. Only one of the values needs to be above a cutoff value for diagnosis.
Two-step
Perform a glucose challenge test as a screen: a woman is given a 50-gram glucose dose to drink and her blood glucose level is measured after 1 hour.
If the challenge test is abnormal, perform a 3-hour oral glucose tolerance test. After a woman's fasting glucose level is measured, she is given a 100-gram
glucose dose and her glucose is measured at timed intervals. If at least two of the glucose levels at fasting, 1 hour, 2 hour, or 3 hour are above a certain
level, then a diagnosis of gestational diabetes is made.
Glucose testing is also used to test women who were diagnosed with gestational diabetes 6-12 weeks after they have delivered their baby to detect persistent
diabetes.
Monitoring
Diabetics must monitor their own blood glucose levels, often several times a day, to determine how far above or below normal their glucose is and to determine
what oral medications or insulin(s) they may need. This is usually done by placing a drop of blood from a skin prick onto a glucose strip and then inserting the strip
into a glucose meter, a small machine that provides a digital readout of the blood glucose level.
Urine
Urine glucose is one of the substances tested when a urinalysis is performed. A urinalysis may be done routinely as part of a physical or prenatal checkup. The
health practitioner may follow up an elevated urine glucose test with blood glucose testing. Urine glucose testing is a screening tool, but it is not sensitive enough
for diagnosis or monitoring.
Other tests, such as diabetes autoantibodies, insulin, and C-peptide, may sometimes be performed along with these tests to help determine the cause of abnormal
glucose levels, to distinguish between type 1 and type 2 diabetes, and to evaluate insulin production.
When is it ordered?
Several health organizations, including the American Diabetes Association (ADA) and the U. S. Preventive Services Task Force (USPSTF), recommend diabetes
screening when a person is age 45 or older or when a person of any age has risk factors. Examples of risk factors include:
A woman who delivered a baby weighing more than 9 pounds or with a history of gestational diabetes
High-risk race or ethnicity such as African American, Latino, Native American, Asian American, Pacific Islander
High blood pressure (hypertension) or taking medication for high blood pressure
Low HDL cholesterol level (less than 35 mg/dL or 0.90 mmol/L) and/or a high triglyceride level (more than 250 mg/dL or 2.82 mmol/L)
If the screening test result is within normal limits, the ADA recommends retesting within 3 years, while the USPSTF recommends yearly testing. People with
prediabetes may be monitored with annual testing.
See the screening articles for Children, Teens, Young Adults, Adults and Adults 50 and Up for additional details.
A blood glucose test may also be ordered when someone has signs and symptoms of high blood glucose (hyperglycemia), such as:
Blurred vision
Sweating
Hunger
Trembling
Anxiety
Confusion
Blurred vision
Diabetics are often required to self-check their glucose, up to several times a day, to monitor glucose levels and to determine treatment options as prescribed by
their health practitioner. The healthcare provider may order blood glucose levels periodically in conjunction with other tests such as A1c to monitor glucose control
over time.
Pregnant women are usually screened for gestational diabetes between their 24th and 28th week of pregnancy, unless they have early symptoms or have had
gestational diabetes with a previous pregnancy. A woman may be tested earlier in her pregnancy if she is at risk of type 2 diabetes (overt diabetes), says the ADA.
When a woman has type 1, type 2 or gestational diabetes, her health practitioner will usually order glucose levels throughout the rest of her pregnancy and after
delivery to monitor her condition.
Blood Glucose
High levels of glucose most frequently indicate diabetes, but many other diseases and conditions can also cause elevated blood glucose.
In a person with signs and symptoms of diabetes or hyperglycemia, a non-fasting glucose level (random blood sample) that is equal to or greater than 200 mg/dL
(11.1 mmol/L) indicates diabetes.
From 100 to 125 mg/dL (5.6 to 6.9 mmol/L) Prediabetes (impaired fasting glucose)
126 mg/dL (7.0 mmol/L) and above on more than one testing occasion Diabetes
Levels applicable except during pregnancy. Sample drawn 2 hours after a 75-gram glucose drink.
From 140 to 199 mg/dL (7.8 to 11.1 mmol/L) Prediabetes (impaired glucose tolerance)
Equal to or greater than 200 mg/dL (11.1 mmol/L) on more than one testing occasion Diabetes
Gestational Diabetes One-Step Approach (as one option recommended by the ADA)
Samples drawn fasting and then 1 hour and 2 hours after a 75-gram glucose drink.
Diagnosis of GDM is made when any of the values exceed the limit.
Gestational Diabetes Two-Step Approach (as currently recommended by ACOG and as one option from the ADA): Step One
Step One: Glucose Challenge Screen. Sample drawn 1 hour after a 50-gram glucose
drink.
140* mg/dL (7.8 mmol/L) and over Abnormal, needs OGTT (see Step two below)
*Some experts recommend a cutoff of 130 mg/dL (7.2 mmol/L) because that identifies 90% of women with gestational diabetes, compared to 80% identified using the
threshold of 140 mg/dL (7.8 mmol/L). ACOG recommends a lower threshold of 135 mg/dL (7.5 mmol/L) in high-risk ethnic groups with higher prevalence of gestational
diabetes.
Gestational Diabetes Two-Step Approach (as currently recommended by ACOG and as one option from the ADA): Step Two
Some other diseases and conditions that can result in an elevated blood glucose level include:
Acromegaly
Acute stress (response to trauma, heart attack, and stroke for instance)
Cushing syndrome
Hyperthyroidism
Pancreatic cancer
Pancreatitis
A low level of glucose may indicate hypoglycemia, a condition characterized by a drop in blood glucose to a level where first it causes nervous system symptoms
(sweating, palpitations, hunger, trembling, and anxiety), then begins to affect the brain (causing confusion, hallucinations, blurred vision, and sometimes even coma
and death). A diagnosis of hypoglycemia uses three criteria known as the Whipple triad. (See the Common Questions section.)
Adrenal insufficiency
Hypopituitarism
Hypothyroidism
Severe infections
Insulin overdose
Starvation
Urine Glucose
Low to undetectable urine glucose results are considered normal. Any condition that raises blood glucose such as diabetes or the other conditions listed above also
has the potential to elevate the concentration of glucose in the urine.
Increased urine glucose may be seen with medications, such as estrogens and chloral hydrate, and with some forms of kidney disease. Some people naturally leak
glucose in their urine when blood levels are normal. Some medications used to treat diabetes work by increasing the elimination of glucose in the urine.
Extreme stress can cause a temporary rise in blood glucose. This can be a result of, for example, trauma, surgery, heart attack or stroke.
Drugs, including corticosteroids, tricyclic antidepressants, diuretics, epinephrine, estrogens (birth control pills and hormone replacement), lithium, phenytoin, and
salicylates, can increase glucose levels, while drugs such as acetaminophen and anabolic steroids can decrease levels.
Common Questions
1. Can I test myself at home for blood glucose levels?
If you are not diabetic or prediabetic, there is usually no reason to test glucose levels at home. Screening done as part of your regular physical should be sufficient.
If you have been diagnosed with diabetes or gestational diabetes, however, your health practitioner or diabetes educator will recommend a home glucose monitor
(glucometer, or one of the newer methods that use very tiny amounts of blood or tests the interstitial fluid -- the fluid between your cells -- for glucose). You will be
given guidelines for how high or low your blood sugar should be at different times of the day. By checking your glucose regularly, you can see if the diet and
medication schedule you are following is working properly for you.
Not in most cases. Glucose will usually only show up in the urine if it is at sufficiently high levels in the blood so that the body is "dumping" the excess into the urine,
or if there is some degree of kidney damage and the glucose is leaking out into the urine. Urine glucose, however, is sometimes used as a rough indicator of high
glucose levels and the urine indicator strip (dipstick) that measures the glucose is occasionally useful for tracking the presence of protein and ketones in the urine.
For type 2 diabetes, which is the most common type of diabetes, losing excess weight, eating a healthy diet that is high in fiber and restricted in carbohydrates, and
getting regular amounts of exercise may be enough to lower your blood glucose levels. In many cases, however, oral medications that increase the body's
secretion of and sensitivity to insulin are necessary to achieve the desired glucose level. With type 1 diabetes (and with type 2 diabetes that does not respond well
enough to oral medications), insulin injections several times a day are necessary. See the article on Diabetes for more on treatment.
If you are diabetic, a diabetic educator (often a nurse with specialized training) can make sure that you know how to:
Recognize and know how to treat both high and low blood sugar
Plan meals; diet is extremely important in minimizing swings in blood glucose levels. A registered dietician can help you learn how to plan meals and a diabetic
educator can help with this as well.
An actual diagnosis of hypoglycemia requires satisfying the "Whipple triad." These three criteria include:
Documented low glucose levels (less than 40 mg/dL (2.2 mmol/L), often tested along with insulin levels and sometimes with C-peptide levels)
Reversal of the symptoms when blood glucose levels are returned to normal
Primary hypoglycemia is rare and often diagnosed in infancy. People may have symptoms of hypoglycemia without really having low blood sugar. In such cases,
dietary changes such as eating frequent small meals and several snacks a day and choosing complex carbohydrates over simple sugars may be enough to ease
symptoms.
Table sugar (sucrose) is a combination of two simple sugars, glucose and fructose, that are both released when table sugar is digested. Because glucose is the
body's primary energy source, the blood glucose test is often informally referred to as a "blood sugar" test.
Related Pages
On This Site
Conditions: Diabetes, Kidney Disease, Pancreatic Diseases, Thyroid Diseases, Cushing Syndrome
Screening: Diabetes - Children (2-12), Teens (13-18), Young Adults (19-29), Adults (30-49), Adults (50 and Up)
In the News: Screening, Diet and Exercise Key Factors in Task Force's New Diabetes Guidelines (2015), Task Force Updates Recommendations for Screening for
Pre-Diabetes and Diabetes in Adults (2014), New Report Finds that Diabetes is on the Rise (2014), FDA Proposes Two Sets of Standards for Glucose Meters
(2014)
American Academy of Family Physicians: Diabetes - Blood tests to help manage your diabetes
FamilyDoctor.org: Monitoring Your Blood Sugar Level
American Diabetes Association
American Association of Diabetes Educators: Patient Resources
Centers for Disease Control and Prevention: Diabetes Public Health Resource
National Institute of Diabetes and Digestive and Kidney Diseases: Diabetes
National Diabetes Education Program: Am I at Risk?
National Diabetes Information Clearinghouse: What I need to know about Gestational Diabetes
Article Sources
NOTE: This article is based on research that utilizes the sources cited here as well as the collective experience of the Lab Tests Online Editorial Review Board. This article
is periodically reviewed by the Editorial Board and may be updated as a result of the review. Any new sources cited will be added to the list and distinguished from the
original sources used. To access online sources, copy and paste the URL into your browser.
(2014 September 22). Diagnosing Diabetes and Learning About Prediabetes. American Diabetes Association [On-line information]. Available online at
http://www.diabetes.org/diabetes-basics/diagnosis/?loc=db-slabnav through http://www.diabetes.org. Accessed October 2014.
(2014 January). Standards of Medical Care in Diabetes 2014. Diabetes Care Volume 37, Supplement 1 [On-line information]. Available online at
http://care.diabetesjournals.org/content/37/Supplement_1/S14.full.pdf+html through http://care.diabetesjournals.org. Accessed September 2014.
Dugdale, D. (Updated 2012 June 2). Glucose test blood. MedlinePlus Medical Encyclopedia [On-line information]. Available online at
http://www.nlm.nih.gov/medlineplus/ency/article/003482.htm through http://www.nlm.nih.gov. Accessed October 2014.
( 19952014). Glucose, Random, Serum. Mayo Clinic Mayo Medical Laboratories [On-line information]. Available online at
http://www.mayomedicallaboratories.com/test-catalog/Overview/89115 through http://www.mayomedicallaboratories.com. Accessed October 2014.
Lin, J. and Yap, S. (Updated 2014 March 18). Glucose Tolerance Testing. Medscape Drugs & Diseases [On-line information]. Available online at
http://emedicine.medscape.com/article/2049402-overview through http://emedicine.medscape.com. Accessed October 2014.
Patolia, S. (Updated 2013 May 20). Glucose. Medscape Drugs & Diseases [On-line information]. Available online at
http://emedicine.medscape.com/article/2087913-overview through http://emedicine.medscape.com. Accessed October 2014.
Rennert, N. (Updated 2012 December 11). Home blood sugar testing. MedlinePlus Medical Encyclopedia [On-line information]. Available online at
http://www.nlm.nih.gov/medlineplus/ency/patientinstructions/000324.htm through http://www.nlm.nih.gov. Accessed October 2014.
Kishore, P. (Reviewed 2014 June). Diabetes Mellitus (DM). The Merck Manual Professional Edition [On-line information]. Available online through
http://www.merckmanuals.com. Accessed October 2014.
Screening for Gestational Diabetes Mellitus: U.S. Preventive Services Task Force Recommendation Statement. Annals of Internal Medicine,18 March 2014, Vol
160, No. 6. Available online at http://annals.org/article.aspx?articleid=1813285&resultClick=24#SummaryofRecommendationsandEvidence through
http://annals.org. Accessed November 2014.
(October 2014) U.S. Preventive Services Task Force Draft Recommendation Statement. Abnormal Glucose and Type 2 Diabetes Mellitus in Adults: Screening.
Available online at http://www.uspreventiveservicestaskforce.org/Page/Document/RecommendationStatementDraft/screening-for-abnormal-glucose-and-type-2-
diabetes-mellitus through http://www.uspreventiveservicestaskforce.org. Accessed November 2014.
Juvenile Diabetes Research Foundation. Continuous Glucose Monitors (Online information) Available online through http://www.jdrf.org. Accessed March 2008.
Johns Hopkins Health Alert. Using a Continuous Glucose Monitor (Online information). Available online through http://www.johnshopkinshealthalerts.com.
Accessed March 2008.
National Institute of Diabetes and Digestive and Kidney Diseases. National Diabetes Information Clearinghouse, Diagnosis of Diabetes (Online information). PDF
available for download at http://diabetes.niddk.nih.gov. Accessed March 2008.
Recommendations of the Expert Committee on the Diagnosis and Classification of Diabetes Mellitus. Diabetes Care, Vol 20(7), Pp 1183-97 (1997).
David E. Goldstein, Hsiao-Mei Wiedmeyer, Randie R. Little, Victor Vargas, Satish S Nair, John Reid. Relationship Between Glycohemoglobin (GHB) and Mean
Blood Glucose (MBG) in the Diabetes Control and Complications Tiral (DCCT). Diabetes 46 (Sup 1), 8A (1997).
Thomas, Clayton L., Editor (1997). Taber's Cyclopedic Medical Dictionary. F.A. Davis Company, Philadelphia, PA [18th Edition].
Pagana, Kathleen D. & Pagana, Timothy J. (2001). Mosbys Diagnostic and Laboratory Test Reference 5th Edition: Mosby, Inc., Saint Louis, MO.
Snow, K. (2001 June 6, Updated). Hypoglycemia. EMedicine.com [On-line Journal]. Available online through http://www.emedicine.com.
Feit, S. (2001 August 30). Drug-induced hypoglycemia. MEDLINEplus Health Information [On-line information]. Available online at
http://www.nlm.nih.gov/medlineplus/ency/article/000310.htm.
Bernal-Mizrachi, C., Updated (2001 June 6, Updated). Glucose Test. MEDLINEplus Health Information [On-line information]. Available online at
http://www.nlm.nih.gov/medlineplus/ency/article/003482.htm.
Spengler, R. (2001 September 18, Updated). Blood Glucose. WebMD Health [On-line information]. Available online through http://my.webmd.com.
MERCK. Hypoglycemia. The Merck Manual of Medical Information Home Edition [On-line information]. Available online through http://www.merck.com.
National Diabetes Information Clearinghouse, NIDDK and NIH. Diagnosis of Diabetes. Available online through http://diabetes.niddk.nih.gov.
Agha, I., Updated (2004 January 26, Updated). Glucose-urine. MedlinePlus Medical Encyclopedia [On-line information]. Available online at
http://www.nlm.nih.gov/medlineplus/ency/article/003581.htm.
(2002 May 01, Updated). Other Diabetes Management Tests, Urine Glucose. Diabetes Information, U.S Food and Drug Administration [On-line information].
Available online through http://www.fda.gov.
(1995-2004). Diabetes Mellitus. The Merck Manual of Medical Information-Second Home Edition [On-line information]. Available online through
http://www.merck.com.
ADA Clinical Practice Recommendations. Diabetes Care 28:S37-S42, 2005. Available online at http://care.diabetesjournals.org.
Tietz Textbook of Clinical Chemistry and Molecular Diagnostics. Burtis CA, Ashwood ER and Bruns DE, eds. 4th ed. St. Louis, Missouri: Elsevier Saunders; 2006,
Pp 860-862.
(Revised 2011 February). Know your Blood Sugar Numbers. National Diabetes Education Program [On-line information]. PDF available for download at
http://ndep.nih.gov/media/knownumbers_eng.pdf through http://ndep.nih.gov. Accessed May 2011.
Olatunbosun, S. (Updated 2011 April 19). Glucose Intolerance. Medscape Reference [On-line information]. Available online at
http://emedicine.medscape.com/article/119020-overview through http://emedicine.medscape.com. Accessed May 2011.
Dugdale, D. (Updated 2010 May 23). Glucose test blood. MedlinePlus Medical Encyclopedia [On-line information]. Available online at
http://www.nlm.nih.gov/medlineplus/ency/article/003482.htm. Accessed May 2011.
Eckman, A. (Updated 2010 April 19). Blood glucose monitoring. MedlinePlus Medical Encyclopedia [On-line information]. Available online at
http://www.nlm.nih.gov/medlineplus/ency/article/003438.htm. Accessed May 2011.
Eckman, A. (Updated 2010 April 11). Managing your blood sugar. MedlinePlus Medical Encyclopedia [On-line information]. Available online at
http://www.nlm.nih.gov/medlineplus/ency/patientinstructions/000086.htm. Accessed May 2011.
Khardori, R. (Updated 2011 May 19). Type 2 Diabetes Mellitus. Medscape Reference [On-line information]. Available online at
http://emedicine.medscape.com/article/117853-overview through http://emedicine.medscape.com. Accessed May 2011.
Pagana, K. D. & Pagana, T. J. ( 2011). Mosby's Diagnostic and Laboratory Test Reference 10th Edition: Mosby, Inc., Saint Louis, MO. Pp 497499.
(Octobert 2008) National Institute of Diabetes and Digestive and Kidney Diseases. Glucose Monitoring. Available online at
http://diabetes.niddk.nih.gov/dm/pubs/glucosemonitor/index.htm through http://diabetes.niddk.nih.gov. Accessed September 2011.
American Diabetes Association. Standards of Medical Care in Diabetes2011. Diabetes Care January 2011 34:S11-S61. Available online at
http://care.diabetesjournals.org/content/34/Supplement_1/S11.full through http://care.diabetesjournals.org. Accessed September 2011.
Metzger BE, et al. International association of diabetes and pregnancy study groups recommendations on the diagnosis and classification of hyperglycemia in
pregnancy. Diabetes Care 2010; 33: 676-82.
This article was last reviewed on December 19, 2014. | This article was last modified on January 16, 2017.
2001 - 2017 by American Association for Clinical Chemistry Contact Us | Terms of Use | Privacy