Você está na página 1de 6

.

DM200 Dual-Channel A/V/D


Vibration Monitor

ProvibTech, Inc. 11011 Brooklet Drive, Suite 300, Houston, Texas 77099, USA

Phone: +1-713-830-7601, Fax: +1-281-754-4972, Email: pvt@provibtech.com , Web: www.provibtech.com

DM200-CAT-E-C-7 COPY RIGHT PROVIBTECH 2012


DM200 Dual-Channel A/V/D Vibration Monitor

DM200 Dual-Channel A/V/D Vibration Monitor


Introduction
DM200 is a dual channel vibration monitor. It is
used to monitoring rotation machines absolute
vibration with acceleration, velocity or
displacement.

Features

9 Dual channels case vibration monitoring


with acceleration, velocity or displacement
9 Independent alert and danger dual relays on Overall Vibration:
each channel 4-20mA source driving load resistance up to
9 Fully digital, long term stability 500.
9 Condition monitoring with waveform and System OK: Each channel output 4-20mA;
spectrum System Fault: Output<3.5mA.
9 Modbus RTU
9 IP 65 or NEMA 4X environmental rating Two Level Alarm:
Alarm setup (Normal/Set):
9 Bright 4 digit LED display
Scalable: 0-100%full scale;
9 Front panel buffered output Accuracy: 0.1%.
9 Wide range of power supply Relays (Alert/Danger):
9 Cost effective Hermetic Seal: Epoxy.
Capacity: 1A/220VAC or 1A/24VDC
resistive load.
Specifications Relay Type: SPDT.
Isolation: 1000VDC
Electrical Alarm Delay:
0-60 seconds.
Power Supply: Selectable with time interval of 1 second.
90-250VAC@ 500mA, 40-60Hz, or
Alarm Multiply:
22-30VDC@ 200mA Switch Trip/Multi and COM, then set Double
Frequency Response: (f3dB): Multiply or Triple Multiply by software, system
Standard: 2.0-3.0KHz; alarm value will increase a factor of 2 or 3.
Integration: 10-3.0KHz. RESET/BYPASS:
Low: 0.5-100Hz. LOCAL RESET;
External Sensor: REMOTE RESET/BYPASS: One shot
Sensitivity: 100mV/g for accelerometer; REST/BYP and COM
4.0mV/mm/s for velocity sensor; LED Machine Condition Indicator:
40mV/mm/s or 4.0mV/um for low CH1 (Green) light on: Display the value of CH1;
frequency velocity/displacement CH2 (Green) light on: Display the value of CH2;
sensor. OK (Green) light on: Self-test passed, System
Current Source: 4mA@24VDC works OK;
Buffered Output: ALARM (red) light on: Alarm indication.
Original vibration, un-filtered; Bus Communication (TX/RX):
Sensitivity/frequency: same as the sensor All Setup and condition parameters can be
specification. obtained from the bus connector.
Impedance :550;
Maximum cable distance: 300m (1000ft).
2
ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com , www.provibtech.com
2
DM200 Dual-Channel A/V/D Vibration Monitor

Digital Condition Monitoring (Optional):


Condition management software, such as Installation:
PCM360 can work with DM200 to collect, store, With specific Holder. Installation in three
and analyze machine running status via the situations: plate installation, rail mounting
digital bus communication of the DM200. installation and installation with TM0303
waterproof case
9 Real-time dynamic waveform
9 Real-time spectrum (800 lines)
9 Real-time case XY vibration
9 Trend plot
9 Alarm list

Physical
Size: 170h90h118mm ( 6.69h3.54h4.64)
Others as per drawing below:
(6.02inch)

Plate Hole Dimension


DM 200 ProvibTech
Environmental
(3.07inch)
(3.54inch)

DUAL VIBRATION MONITOR


CH 1 CH 2

OK/TX OK/TX Temperature:


ALARM ALARM Operation:-25~+70;
Storage:-40~+100.
- SET + Humidity: 95%non-condensing.

(6.69inch)
Front View

Side View
Weight:
1300 g.

2
ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com , www.provibtech.com
3
DM200 Dual-Channel A/V/D Vibration Monitor

Ordering Information F1: 24 VDC

DM200-AXX-BX-CX-D1-EX-FX * Factory default


AXXFull Scale
A12: 0 ~ 5.0g pk Accessories
A13: 0 ~ 10g pk DM200-CFG-K
A40*: 0 ~ 20mm/s rms DM200 configuration and calibration software kit
A41: 0 ~ 25 mm/s rms includes:
A42: 0 ~ 50mm/s rms
A43: 0 ~ 100mm/s rms 9 DM200-CFG configuration and calibration
A46: 0 ~ 1.0 ips rms software CD
9 RS485-USB converter with cable
A47: 0 ~ 2.0 ips rms
A48: 0 ~ 4.0 ips rms PCM-TCP: Modbus RTU-TCP Converter
A50: 0 ~ 20mm/s pk
A51: 0 ~ 25 mm/s pk TM0782A-K-M: Accelerometer Kit.
A52: 0 ~ 50mm/s pk TM0783A-K-M: Accelerometer with Integral
Cable.
A53: 0 ~ 100mm/s pk TM0793V-K-M: Velocity Sensor Kit.
A56: 0 ~ 1.0 ips pk TM079VD-V/H-K: Low Frequency Velocity/
A57: 0 ~ 2.0 ips pk Displacement Sensor.
A58: 0 ~ 4.0 ips pk
A60: 0 ~ 100um pk-pk TM0303: NEMA Housing.
TM0401: Barrier.
A61: 0 ~ 125um pk-pk
A62: 0 ~ 200um pk-pk
A63: 0 ~ 250um pk-pk
A64: 0 ~ 500um pk-pk
A66: 0 ~ 5mil pk-pk
A67: 0 ~ 10mil pk-pk
A68: 0 ~ 20mil pk-pk
BX: Sensor (not include)
B0*: TM0782A, TM0783A, or any ICP
Accelerometer with 100mV/g (A60-A68 not
applicable)
B1: TM0793V or any ICP Velocity Sensor with
4mV/mm/s (A12, 13 not applicable)
B2: TM079VD (A12, 13 not available)
BXXX: Seismic Sensor, Sensitivity = XXX
CX: Frequency Response
C0*: Normal Frequency (B2 not applicable)
C1: Low Frequency (B2 only)
DX: Environmental Rating (front panel)
D1*: IP65 or NEMA 4X
EX: Digital Communication
E0*: No digital communication
E1: With Modbus
E2: With Modbus and Digital Condition
Monitoring
FX: Power Supply
F0*: 110 VAC or 230 VAC

2
ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com , www.provibtech.com
4
DM200 Dual-Channel A/V/D Vibration Monitor

DM200 Field-wiring Diagram for TM0782A, TM0793V, TM079VD or other ICP sensor

4-20mA(A)
4-20mA(B) (+)
(+) B-4-20 A-4-20
(-) B-COM A-COM (-)

B-BUF A-BUF
Shield Wire Shield Wire
COM COM
Red Wire Red Wire
B-P/A A-P/A
White Wire White Wire
B-S/B A-S/B
Trip-Multiply

TR+ TR-
RS-485
TRIP/MLTP BUS+
reference
or phase

COM BUS-
input

RESET/BYP COM
B-AC A-AC
B-A A-A
Remote
Reset

B-AO A-AO
B-DC A-DC
B-D A-D

ALERT
ALERT

B-DO A-DO
TO

(B)

(A)

TO
DANGER
DANGER
TO

(B)

(A)

TO

N L

32:(56833/< 32:(56833/<
90250VAC 2230VDC

DM200 Nonhazardous Area

2
ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com , www.provibtech.com
5
DM200 Dual-Channel A/V/D Vibration Monitor

4-20mA(A)
4-20mA(B)
(+)
(+) B-4-20 A-4-20
(-) B-COM A-COM (-)
B-BUF A-BUF
Shield Wire Shield Wire
COM COM
Red Wire Red Wire
B-P/A A-P/A
White Wire White Wire
B-S/B A-S/B

TR+ TR-
Trip-Multiply

RS-485
TRIP/MLTP BUS+
reference
or phase

COM BUS-
input

RESET/BYP COM
B-AC A-AC
B-A A-A
Remote
Reset

B-AO A-AO
B-DC A-DC
1 2 2 1
B-D A-D
TM0401 TM0401

ALERT
DANGER ALERT

B-DO A-DO
TO

(B)

(MTL787SP+) (MTL787SP+)

(A)

TO
3 4 4 3

DANGER
Red Wire Red Wire
TO

(B)

Shield Wire

TO
(A)
Shield Wire

N L

32:(56833/< 32:(56833/<
90250VAC 2230VDC

DM200 Hazardous Area

Note:
9 If the DM200 has the digital condition monitoring function, the Trip/Multi and COM pins are used for
phase reference input. Moreover, the DM200 wont provide Multiply Alarm function anymore, so you
should set Multiply Alarm property to None by DM200-CFG software.

2
ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com , www.provibtech.com
6

Você também pode gostar