Você está na página 1de 15

,.

I " , I

IS : 1570 ( Part 2/Sec 2 ) - 1987

Indian Standard
SCHEDULES FOR WROUGHI' STEELS
PART 2 CARBON STEElS ( UNALLOYED STEELS )
Section 2 Carbon Steel Wires with Related Properties

( First Revision )

UDC 66914-426

@ Copyright 1988

BUREAU OF INDIAN STANDARDS


MANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG
NEW DELHI 110002

Gr 4 March 1988
r

IS : 1570 ( Part 2/Scc 2 } - I 98-1

Indian Standard
SCHEDULES FOR WROUGHT STEELS
PART 2 CARBON STEELS {UNALLOYED STEELS )

Section 2 Carbon Steel Wires with Related Properties

( First Revision )
Alloy Steels and Special Steels Sectional Committee, S?vlDC 19
Chairman Repre: e:1ting
DR G. MuKHI:RJEE Steel Authority of India Ltd, l'\ t w Delhi
1\fembers
Am>l'l'lOX AL OIJtECT Olt ( MET) Ministry of Railwa ys
JoJXT Dlln:cTo n ( CJn:IIJCM,) (Alternate)
SHHI JL\l,KHJ:-:ilL.>.N r\<.;UAltWAL Federation of Engineering Industries of India
SHm H . S. CurTA ( Alternate)
SHnr S. K. B:~.s1.: P.f. N. Dastur & Co Pvt Ltd, C<tlcutta
SHRI C.) . D .-\VE (Alternate)
SHRT .J . !" . l3JJ .\TT .-\( ' llAHYYA f\:ationnl Te~t HousC', Cnkutta
SIll: 1 S. C. BJJ .-\ w ,, L ( Alternate )
Sum A. K . CHAKIL\IWRTY Guest, Keen, \t\'illiams Ltd, Howrah
Smu S. N. SARVAR (Alternate)
Smn D. K. D.-\S Heavy Engineering Corporation Ltd, Ranchi
SHm B. P. SINGH ( Alternate)
DEPCTY DIRECT0l{ INSPECTION Directorate General of Supplies & Disposals
( Inspection Wing), New Delhi
SHIH D. K . P,,t:L (Alternate)
SJ1In A. D. DI.-\.s Indian Tool Manufacturers Ltd, Bomba y
SHRI D . G.-\DH Ahmedabad Advance Mills Ltd ( .Special Alloy Steel
Division), T'\avsari
Smu :\sDr CH .-\ TTEHJEr; ( Altemate)
G);EH.-\L j\,f..\N.-\ C ER Mishra Dhatu Nigam Ltd, H ydcrabad
Dn M . NAGESll\L\lt RAO ( Altemale)
SHHJ ] . L . GoY .-\L ?viodern Steel Ltd , Mandi Gobind Garh
SHHJ R . C. ]H:\. Allo ys Steels Plant (SAIL), Durgapur
SJ1Jn S. Kc:-.L-\lt Indian Register of Shipping , Bomba)'
Sllln VJPOX GIIOPJ: .\ (Alternate)

( Co!l!inued on pa.~e 2)
Copyright I 988
BUREAU OF INDIAN STA!\!DARDS
This publication is protected under the Indian Cap]right Act ( XIV of 1957) and
reproduction in whole or in part by any me<Jns E'XCC'p! with wr)tt('n perm ission of the
publisher shall be deemed to be an infringement of copyright under !he said Act.
IS : 1570 ( Part 2jSec 2 ) - 1987

( Continued from page 1 )

Members R epresentirzg
DR D. P. LAHllU Ministry of Defence ( R&D )
S:am I. N. BHATIA ( Alterrwte)
SHRI LAXMAN MISHRA Directorate General of Technical Development,
New Delhi
Sn:nrS. S. KHOSLA ( Alternate)
DR T. MUKHERJEE Tata Iron & Steel Co Ltd, Jamshedpur
S.RRI A. N. MITRA ( Alternate)
Dn. S. K. MONDAL Tata Engineering and Locomotive Co Ltd,
Jamshedpur
DR P. G. RENAVI!i:ER (Alternate)
SHRI D. B. MoHORIL Steel Furnace Association of India, Calcutta
D:n. K. SuBRA?dANYAM (Alternate)
SHm P. NARAIN Mahindra Ugine Steel Co Ltd, Bombay
SHRI C. R. SHARMA ( Alternate) .
SHRI I. K. NAYAR Firth (India) Steel Co Ltd, Thane
SBRI K. A. SREROY (Alternate)
DR R. V. PATRY Alloy Steel Producers' Association of India, Bombay
Snnr G. R. PRAKASH Visvesvaraya Iron & Steel Ltd, Bhadravati
SRRI B. HARIDASA AcHAR (Alternate)
SHm M. K. PRAMAN'IK. Ministry of Steel & Mines (Iron & Steel Control),
Calcutta
SRRI S. S. SAUA ( Alternate)
SHRI RAGIIUBIR SINGH National Metallurgical Laboratory ( CSIR ),
Jamshedpur
SHRI S. RAJAGOPALAN' Addison & Co Ltd, Madras
Smn V. Sn1NIV ASAN ( Alternate )
DR V. RAMASWAMY Research and Development Centre for Iron and
Steel ( SAIL ), Ranchi
SRRI S. R. MEDmA'I'TA (Alternate)
SHRI H. s. RAMCHANDRA HMT Ltd
SHRI P. RAMA Pn.ASAD (Alternate I )
SRRI A. SHANTHARAM (Alternate II)
SHRI V. N. VENKATESAN (Alternate III )
REPRESENTATIVE Modi Steels, Modi Nagar
SHRI M. K. SEN Ministry of Defence ( DGI)
SRRI K. L. CnAKRABO-q,TY (Alternate)
Snm B. K. SJIARMAH Ministry of Defence ( OFB )
SHRI A. K. BANGA ( Alternate )
SHRI B. Mux.s:En.Jr, Director General, BIS ( Ex-officio Member)
Director ( Struc and Met )
Secretary
Smn S. K. PANJA
Assistant Director ( Metals ) , BIS

( Continued on page 14 )

2
IS : 1570 ( Part 2/Sec 2 ) 1987
( eontinued from page 2 )

Subcommittee for Revision of IS : 1570, SMDC 19: 5


Convener Representing
SanrP.K.CHAKRAVAnTY M. N. Dastur & Co Pvt Ltd, Calcutta
Members
Smn A. K. CffAKRAVORTY Guest, Keen, 'Williams Ltd , Howrah
Snnr K. L. CHAKRA:80RTY Ministry of Defer,ce ( DGI )
Snnx G. N. KIIADENGAN ( Alternate)
Dn S. CnAlGtAVOR'I'Y Usha Alloy and Steds Ltd, .Jamsh<>dpur
S.a:ni K. BALAltAMAMURTHY Nuclear Fuel Complex, Hyderabad
Srrnl R. KALIDAS ( Alternate) .
SHRI R. C. ]HA Alloy Steels Plant (SAIL), Durgapur
JoiNT Dm.ECTon ( ME'I' ), RDSO MiniStry or-Railways
AssiSTANT DIBEOTOR, RDSO (Alternate)
DR K. V.; KtusRNAMU::aTRY Sundaram Fasteners Ltd; Madras .
Snnt D. jAYARAMAN (Alternate-)
S.an1 A. N. MtrRA Tata Iron & Steel Co Ltd, Jamshedpur
SRRI SuaESH GUPTA (Alternate)
Dn N, MoRAN'' Bihay Alloy Steels Ltd, Ran<Zhi .
SHRI PnAKAS.H NARAIN Mahindra. Ugine Steel Co Ltd, Bombay
Sl1n1 R. BALAJI (Alternate}
Dn R. V. PATTIY Alloy Steel Producers' Association of India, Bo
Sl1Rl M. K. PRAMANIK Iron &,Steel Control, Calcutta
S.!IRI s. PANOIT Foundry Forge Plant, Heavy Engineering C
ration Ltd, Ranchi
SHnr D. K. DAs (Alternate)
SaRI A. K. RoY Association of Indian Automobile Manufactui
Bombay
SHRI K. K. SEN Pratap Steel Rolling Mills Ltd, Ballabgarh
SHRI S. N. SrNGH Tata Engineering & Locomotive Co Ltd,Ja.mshc
Da G ..VENK'ArrARAMA.N Bharat Heavy .ElectricalsLtd, Tiruchchirappalli
SH.RI D .. R. VERNll:KAR Visvesvaraya Iron .& Steel Ltd, Bhadravati
S.aRJ B. HARIDASA Ac:nAR ( Alternate )

14
IS: 1570 ( Part 2jSec 2 ) - 1987

Indian Standard
SCHEDULES FOR WROUGHT STEELS
PART 2 CARBON STEELS { UNALLOYED STEELS )

Section 2 Carbon Steel Wires with Related Properties

( First Revision )

0. FORE WORD
0.1 This Indian Standard ( Part 2/Sec 2 ) ( First Revision ). was
adopted by the Bureau of Indian Standards on 25 June 1987, after the
draft finalized by the Alloy Steels and Special Steels Sectional Committee
had been approved by the Structural and Metals Division Council.
0.2 Schedules for wrought steels for general engineering purposes ( IS :
1570) was first published in !961. On the basis of the experience gained
in the production and use of steels, the Sectional Committee has decided
to revise the standard and issue it in parts . The other parts of the
standard are as follows:
Part 1 Steels specified by tensile and/or yield properties.
Part 2 Carbon steels ( una1loyed steels ), Section I Wrought products
( other than wires ) with specified chemical composition and
related properties.
Part 3 Carbon and carbon manganese free cutting steels.
Part 4 AHoy steels ( alloy constructional and spring steels ) with
specified chemical. composition and related mechanical
properties ( under revision ).
Part 5 Stainless and heat resisting steels.
Part 6 Alloy tool steels ( under revision ).
Part 7 Steels for elevated temperature services ( creep resisting
steels ) ( under revision ).
0.3 The following major modifications have been made in this revision:
a) Tensile strength values are given in MPa instead of kg(mm 2 .
b) The detaile:l mechanical properties of different types of wires
for various end use-) have been included.

3
IS 4 1570 ( Part 2JSec 2 ) - 1987

1. SCOPE
1.1 This schedule ( Part 2JSec 2 ) is applicable to wire produced from
carbon steels for a wide variety of purposes.

2. GENERAL
2.1 In many cases, the necessary properties are produced in the w,ire by
cold drawing rod or wire, after appropriate heat treatment, from a
predetermined size to the required diameter. As the tensile strength
thus attained is a function of both the initial and final diameters, by
selection of a steel of suitable composition, appropriate preliminary
heat treatment, for examp1e, annealing or patenting; and appropriate
initial diameter; a wide variety of tensile strengths may be obtained.
The very high tensile strength can, however, only be attained in the
smaller sizes owing to the large amount of cold drawing required.
In many cases, it is sufficient to specify the tensile properties
without specifying a chemical composition, other than the maximum
permissible limits of sulphur and phosphorus, but when detailed
chemical composition is considered necessary, these may be selected
from steels in Part 2, Sec 1 in relation to the diameter of the wire and
the tensile strength level required.
T.able 1 specifies the tensile strength limits for mild steel wire while
Tables 2 to l3 refer to drawn wire for wood screws, rivets, spokes and
nipples, bead wire for -tyres, staple pins, needles, umbrella ribs, split
pins, reeds and steel wire for aluminium conductors. The specified
tensile properties for hard drawn wire for ropes, upholstery springs,
telegraph and telephone wires, cold formed springs, valve springs, etc,
are covered in Tables 14 to 18. The hard drawn wires for prestressed
concrete and concrete reinforcement are covered in Tables 19-22.
Any tests, additional to the tensile test, for example, torsion test,
wrapping rest, etc, should be specified in the standard as appropriate.

TABLE 1 SPECIFIED TENSILE LIMITS FOR MILD STEEL WIRE


( Clause 2.1 )

CONDITION TENSILE STRENGTH


MPa
Annealed 500 Max
Soft drawn 550 Max
! Hard 450-650
i Hard 600-800
Hard 700-9.59

4
IS : 1570 ( Part 2/Sec 2 } " 1987

TABLE 2 SPECIFIED TENSILE LIMITS FOR WIRE FOR WOOD SCREWS


AND MACHINE SCREWS
( Clause 2.1 )
TENSILE STRENGTH
MPa
Wood screw 460 Min
Machine screw - Grade I 440-590
Grade II 590-780

TABLE 3 SPECIFIED TENSILE PROPERTIES FOR STEEL WIRE FOR


COLD-FORGED RIVETS {UP TO 20 mm)
( Clause 2.1 )

TENSILE YIELD STRI'.'SS ELONGATION, PERCENT


STRENGTH MPa Min (ON GAUGE LENGTH)
MPa Min 565 .Y So
Annealed condition 330-410 160 30
As drawn condition 410-490 190 20

TABLE 4 SPECIFIED TENSILE LIM:ITS FOR STEEL WIRE FOR SPOKES


AND NIPPLES
( Clause 2.1 )

TENSILE STRENGTH
MPa
Spoke 1 000-1 300
Nipple 490-640

TABLE 5 SPECIFIED TENSILE PROPERTIES FOR BEAD WIRE FOR TYRES


( Clause 2.1 )

SIZE oF wmE TENSILE STRENGTH ELONGATION AT


MPa (Min) . 200mm ( GL)
PERCENT,
mm Min
0965 1 860 3
180 1 720 3
I 470 3
1 720 3
1 420 4
NoTE - Bronze, 'brass and copper plated wires shall be heated in superheated
steam at 150C for one hour before testing.
1 MPa = 1 Njmm 2 = 1 MN{m 2 = 0102 0 kgf/mm 2

5
IS : 1570 ( Part 2/Sec 2 ) - 1987

TABLE 6 SPECIFIED TENSILE LIMITS FOR STEEL WIRE FOR STAPLES,


PINS AND CLIPS
( Ctause 2.1 )
TYPE TENSILE STRENG.rH
MPa
1 590-880
2 685-980
3 1 1751 570

TABLE 7 SPECIFIED TENSILE LIMITS FOR STEEL WIRE FOR NEEDLES


( Clause 2.1 )
GR.ADE TENSILE STRENGTH
MPa
I 610-730
II 630-760
III 490690

TABLE 8 SPECIFIED TENSILE LIMITS FOR WIRE FOR UMBRELLA RIBS


('Clause 2.1 )
TYPE Oil' wn~E GruDE SrzE RANGE TENSILE SnmN'GTH
mm MPa
Hardened /tern pered 1 I6o-soo 1 570-1 870
As drawn 2 1604oo 1 270-1 570
As drawn 3 160-250 I 570-1 870

TABLE 9 SPECIFIED TENSILE PROPERTIES FOR WIRE FOR[SPLIT PINS


( Clause 2.1 )
NoitUNAL SrzE GAUGE LENGTH TENSILE STRENGTH ELONGATION, PERCENT
r-- - A--~
Over Up to mm MPa, Max Min
1'6 125 450 10
16 4 250 450 10
4 8 times the nominal 450 20
SIZe

TABLE 10 SPECIFIED TENSILE LIMITS FOR STEEL WIRE FOR REEDS


( Clause 2.1 }
TENSILE STRENGTH
MPa
600-900

6
IS : 1570 { Part 2/Sec 2 ) 1987

TABLE 11 SPECIFIED TENSILE LIMITS FOR STEEL WIRE FOR HEALD


( Clause 2.1 )
TENSILE STRENGTH
MPa
1 100 1\1iiz Hardened and tempered
a) 1 300~1 700 l
Patented and drawn
b) 1 600-2 000 j
TABLE 12 SPECIFIED TENSILE PROPERTIES FOR DRAWN TINNED STEEL
WIRE FOR BANDING ARMATURES AND ROTORS
( Clause 2.1 )
TENSILE STRENGTH 02 PERCENT PROOF STRESS
MPa, Min MPa, Min
1 760 1 280

TABLE 13 SPECIFIED TENSILE PROPERTIES FOR ALUMINIZED STEEL


CORE WIRE FOR ALUMINIUM CONDUCTORS ( ACSR)
( Clause 2.1 )
NOMINAL DIA)IETEH. TENSII,E STRESS AT 1 PERCENT ELONGATION PERCENT
mm STRENGTH ExTENSION
r - - - ---A-----~ MPa, Mm Min
Over Up to Min MPa ( Gauge Length = 250 mm )
125 224 1 275 1 170 35
224 315 1 240 1 100 40
3'15 355 1 205 1 030 40
355 376 1 170 1 000 50
375 1 135 930 so

TABLE 14 SPECIFIED TENSILE LIMITS FOR HARD DRAWN STEEL WIRE


FOR ROPES
( Clause 2.1 )
TENSILE DESIGNATION TENSILE STRENGTH
MPa
1230 I 230-I 620
1420 1 420-1 810
1570 1 570-1 960
1770 1 n o-2 160
1960 1 960-2 340

7
r

IS : 1570 { Part 2jSec 2 ) - 1987

TABLE 15 SPECIFIED BREAKING LOAD FOR STEEL WIRE FOR


TELEGRAPH AND TELEPHONE
( Clause 2.1 )
NOMINAL DIAMETER. BnEAlUNO LOAD*, N.
mm Min
660
940
1 160
I 305
250 1 815
280 2 295
355 3 660
40 4 680
560 9 170
*The values are based on nominal diameter of wire.

TABLE 16 SPECIFIED TENSILE LIMITS FOR HARD DRAWN STEEL


WIRE FOR UPHOLSTERY SPRING
( Clause 2.1 )

NoliUNAL DIAMETER TENSILE S .r tmNG'l'II, .M:Pa


mm ...- - - -- - -..A.---- - - ---..,
Grade I Grade II
120 to 200 1 700-2 000 2 000 to 2 300
210 to 2'65 1 550-1 750 1 750-1 950
280 to 355 1 450-1 650 1 600-I 800
4' 00 1 450 Min 1 450 Min

TABLE 17 PHYSICAL PROPERTIES OF PATENTED AND COLD


DRAWN STEEL WIRE FOR COLD FORMED SPRINGS
( Clause 2. 1 )

UNCOATED TENSILE STRENGTH, MPa, Min REDUCTION IN AREA,


WIRE DrA ~---------A---- -------.., hR~N~
(NOMINAL) Grade 1 Grade 2 Grade 3 Grade 4 Min
mm
(1) (2) (3) (4) (5) (6)
0'0? 2 550
008 2 540
009 2 530
010 2 530
( Contirzued )

8
r

IS : 1570 ( Part 2JSec 2 ) .. 1987

TABLE 17 PHYSICAL PROPERTIES OF PATENTED AND COLD


DRAWN STEEL WIRE FOR COLD FORMED SPRINGS - Contd

UNCOATED TENSILE STRENGTH, MPa, .lvlin REDUCTION IN AREA,


WIRE DIA ~--------~--------- PERCENT,
( NoMI::-l'AL) Grade 1 Grade 2 Grade 3 Grade 4 Min
mm
( I) (2) (3) (4) (5) (6)

011 2 520
0'12 2 520
014 2 510
016 2 500
018 2 500
020 2 490 2 700
022 2 480 2 680
025 2 470 2 670
028 2 460 2 660
030 1 720 2 060 2 460 2 660
0 32 1 710 2 050 2 450 2 650
034 1 710 2 050 2 450 2 640
036 1 700 2 040 2 440 2 630
038 1 700 2 040 2 430 2 620
040 1 700 2 040 2 430 2 620
043 1 690 2 030 2 420 2 610
045 1 680 2 020 2 410 2 600
048 1 680 2 020 2 400 2 590
050 I 670 2 010 2 390 2 580
053 1 660 2 000 2 380 2 570
056 1 660 2 000 2 370 2 560
060 1 650 1 990 2 360 2 550
o63 1 640 l 980 2 340 2 540
065 l 640 1 980 2 330 2 540
070 1 630 1 970 2 320 2 530
075 1 620 I 960 2 300 2 500
oao 1 610 1 950 2 280 2 480
0'85 1 600 1 930 2 260 2 460
0'90 1 590 1 920 2 250 2 440
095 1 5BO 1 910 2 250 2 420
100 1 570 1 900 2 240 2 4oo
105 1 560 1 890 2 210 2 380\
11 0 I 550 40
1 8BO 2 190 2 370J
( Continued )

IS : 1570 ( Part 2/Sec 2 ) - 1987


TABLE 17 PHYSICAL PROPERTIES OF PATENTED AND COLD
DRAWN STEEL WIRE FOR COLD FORMED SPRINGS - Contd
UNCOATED REDUCTION JN AREA,
. TENSILE STRENGTH, MPa, Min
WIRE DIA ~~--------~---------, PERCENT,
(NoMINAL) Grade 1 Grade 2 Grade 3 Grade 4 Min
mm
(1) (2) (3) (4) (5) . (6)
!20 1 540 1 860 2 I70 :1.3401
125 1 530 1 850 2 140 2 320 1
130 I 520 1 840 2 130 2 300 1
!40 1 500 1 820 2 110 2 290 1
150 1 490 l 800 2100 2 260 l
!60 1 470 I 780 2 080 2 250 1
170 1 460 1 760 2 050 2 220 I
180 1 440 1 750 2 030 2 190 1
190 1 430 1 730 2 OIO 2 180 1
20 1 420 1 720 1 990 2 160 l
21 1 410 1 700 1 960 2 130 >-. 40
225 1 400 1 680 1 940 2 100 I
240 2 010 I
25
26
l 380
I 370
1 360
1 660
l 640
1 620
1 910
1 890
1 860
2 050
2 030
I
28 1 340 I oOO 1 840 2 ooo I
30 1 320 1 570 1 830 1 980 l
32 1 310 1 550 1 790 I 960!
34 1 290 1 530 1 760 1 920 I
36 1 270 1 510 1 750 1 890 1
3.8 1 260 1 490 1 720 1 860J
40 1 250 1 480 1 700 I 840l
4'25 1 250 l 460 1 680 l 820 I
45 1 230 1 440 1 660 I 800 I
475 1 210 1 420 1 620 1 770 I
so 1 190 I 390 1 600 1 750 1
53 1 170 1 370 1 570 1 720 >- 35
56 1 150 1 350 1 550 1 690!
60 1 130 1 320 1 530 1 670 l
63 I 120 1 310 1 500 1 640 1
6'5 1 110 1 290 1480 1 620 !
70 I 090 1 260 1 460 1 610 J
75 1 070 1 250 1 430 1 570 1
80 1 050 1 2'LO 1 400 1 540 ~ 30
8'5 1 020 1 200 I 370 1 500 I

90 1 000 1 180 1 350 1 480)


9'5 990 1 150 1 310
10'0 980 1 130 1 290
105 1 100
11'0 1 080
120' 1 040
125 1 030
130 1 020
140 990
150 970
160 960
170 950
NoTE 1 - I MPa = I N/mm = 1 MNfm 2 = O l 020 kgffmm 2
2

NoTE 2 -The maximum tensile strength of a particular grade shall be the mini-
mum tensile strength of the next higher grade subject to a maximum range of
250 Nfmm 2 between the maximum and the minimum : In case of Grade 4, the
higher limit may be mutually agreed to between the purchaser and the manufacturer ..

10
IS : 1570 ( Part 2/Sec 2 ) ~ 1987

TABLE 18 TENSILE PROPERTIES OF OIL HARDENED AND TEMPERED


SPRING STEEL WIRE AND VALVE SPRING WIRE
( Clause 2.1 )
WIRE Dr.a ToLERANCE TENSILE STRENG'IH, REDUCTION IN AREA,
(NoMINAL) MPa, Min, FOR P:r;RCENT, Min, FOR
Gn.ADES GRADES
~----~----~ ~----~-- --~
mm mm sw vw sw vw
(1) (2) (3) (4) (5) (6)
100 I 760 1 670
105 to to
110 0015 1 960 1 810
120
---------
1 720 1 620
I25 to to
130 1 910 I 760
!40

150
1'60 1 670 1 570
170 0020 to to
180 1 860 1 690
190 I
I
45 45
20
2'1
I 1 620
to
1 520
to
225 1 760 1 620
24
-------
25 0030
------------
1 570 1 470
26 to to
28 1 720 1 620
------- -----------
30 1 520 1 430
32 to to
------
34
- ----------- I 670 1 530
-------
36
-------------
I 480 1 400
38 to to
-------
40
1 630 1 500 ------------
425
- - -------- .. --
42 42
------- 004 l 440 l 370
45 to to
475 1 590 1 470 ------------
50
-----
53
------------
1 400 I 340
56 to
-----
60
-----------
006
1 550
to
1 440
40 ~0

( Continued
11
IS : 1570 (Part 2/Sec 2 ) - 1987

TABLE 18 TENSILE PROPERTIES OF OIL HARDENED AND TEMPERED


SPRING STEEL WffiE AND VALVE SPRING WIRE - Contd
TENSILE STRENGTH, REDUCTION IN AREA,
WIRE DrA TOLERANCE
MPa, Min, .FOl~ PERCENT, Min, FOR
(NOMINAL)
GRADES GRADES

1 360 1 300 40 40
to to
1 510 1 400 38 38
006 - -----------1
80
1 290
85 to
- -- - - - - - -- - -- - - - - 1440
90
95 ------- - ----
oos
100
35
10 5 1 250
11'0 to
120 I 400
125 012
130
140
NoTE - 1 N/mm 2 = 1 MN/m 2 = Ol 020 kgf/mm 2

TABLE 19 SPECIFIED TENSILE LIMITS FOR HARD DRAWN STEEL WIRE


FOR PRESTRESSED CONCRETE .
( Clause 2.1 )
No:r.nN AL DIAMETER TENSILE STRENGTH
mm MPa
Min
325 1 765
400 I 715
soo 1 570
NoTE- 1 Nfmm 2 = I MNjm 2 = 01 020 kgfjmm 2

12
IS : 1570 ( Part 2,S(c 2)- 1987

TABLE 20 SPECIFIED TENSILE LIMITS FOR COLD DRAWN AND STRESS


RELIEVED WIRE FOR PRESTRESSED CONCRETE
(Clause 2.1 )
No?tf:INAL DrAMF.:TER TENSILE STRENGTH, Min ELONGATION, PERCENT
mm MPa Min ( GL 200 mm )
250 2 010 250
300 1 860 250
400 1 715 300
500 I 570 4oo
700 1 470 400
800 I 370 400

TABLE 21 SPECIFIED TENSILE PROPERTIES FOR HARD DRAWN STEEL


WIRE FOR CONCRETE REINFORCEMENT
( Clause 2.1 )
TENSILE ST.RENOTH 02 P.En CENT PnooF ELONGATION, PERCENT
STRESS ( GL 8D)
MPa MPa
570, Min 480, Min 75 Min

TABLE 22 SPECIFIED TENSILE PROPERTIES FOR INDENTED HARD


DRAWN STEEL WIRE FOR PRESTRESSED CONCRETE
{ Clause 2.1 )

NoMINAT, DIAMETER TENSlLE STRENGTH 02 PER OENT PROO:J' ELONGATION PER-


Min STRESS, Min CENT, Min
mm MPa MPa ( GL 200 mm)
soo I 570 1 335 35
400 I 715 I 460 3
300 1 860 1 580 25

13

Você também pode gostar