Submersible

pump cable
TML flat type B 0.6/1kV

Cable Design Submersible pump cable flat type B (application in potable water)

Conductor: plain annealed copper, flexible class 5 acc. to


DIN EN 60228
Separator: optional
Insulation: Special rubber, compound type EI6 acc. to
EN 50363-2-1.
Core arrangement: Cores layed in groups of 34 cores - parallel arranged.
Color sequence: acc. to DIN VDE 0293-308
3-core: brown, black, grey
green/yellow, blue, brown
4-core: green/yellow, brown, black, grey
Outer sheath: Special rubber, compound type EM6, acc. to
EN 50363-2-1.
Color: blue
Identification: Printing: e.g. TML-B 3 x 4 mm + manufacturers
identification thread
- Not true to scale -

Reference standard
National International

DIN VDE 0250 generally to IEC 60245


EN 50363-1 generally to IEC 60245
EN 50525-2-21
DIN VDE 0282 part 16
DIN EN 60228 IEC 60228
DIN VDE 0298 part 300
DIN VDE 0472 corresponding parts
DIN VDE 0473 corresponding parts IEC 60811 corresponding parts

Application
These cables are approved for connection of electrical Equipment in drinking water and water for industrial
purpose up to submersing depth of 400 m. They are also applicable in dry, damp, and wet rooms and
outdoors, but not exposed to direct sunlight. They also can be used in seawater.

PRYSMIAN 2012, All Rights Reserved


All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian: any modification or
alteration afterwards of product may give different result.
The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without
the written consent of Prysmian. The information is believed to be correct at the time of issue. Prysmian reserves the right to amend this
specification without prior notice. This specification is not contractually valid unless specifically authorized by Prysmian.

Data Sheet No.: DB-S-044B2012en/JF www.prysmiangroup.com Issued 2013-07-11 YA/MK/ Page 1 of 4


Technical Parameter
Rated voltage: 0,6/1 kV
Test voltage: 3 kV / 5min
Temperature range for operation: for storage - 40 up to + 70C
in motion - 25 up to + 70C
Conductor temperature: in operation Max. + 90 C
short circuit Max. + 250 C
Resistance to water EN 50525-2-21 App. E
Compatibility to drinking water ACS and KTW
Seawater compatibleness given
Minimum bending radius: cable thickness 8 mm 12 mm > 12 mm
fixed 3xD 3xD 4xD
in motion 3xD 4xD 5xD
Part No.:
Electrical characteristics at 20C: Nominal cross-section Main core resistance max. /km
1,5 13,3
2,5 7,98
4 4,95
6 3,30
10 1,91
16 1,21
25 0,78
35 0,554
50 0,386

PRYSMIAN 2012, All Rights Reserved


All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian: any modification or
alteration afterwards of product may give different result.
The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without
the written consent of Prysmian. The information is believed to be correct at the time of issue. Prysmian reserves the right to amend this
specification without prior notice. This specification is not contractually valid unless specifically authorized by Prysmian.

Data Sheet No.: DB-S-044B2012en/JF www.prysmiangroup.com Issued 2013-07-11 YA/MK/ Page 2 of 4


Dimensions
Number of cores x Conductor Insulation wall Inner jacket Outer jacket Cable Cable weight
nominal cross-section diameter thickness wall thickness wall thickness dimensions. approx.
approx. approx. approx. approx. width /
height
mm mm mm mm mm mm kg/km
13.2 0.3 /
3 G 1.5 - 0.8 - 1.6 140
06.5 0.2
13.2 0.3 /
3 x 1.5 - 0.8 - 1.6 140
06.5 0.2
15.3 0.3 /
3 x 2.5 - 0.9 - 1.6 190
07.3 0.2
17.8 0.5 /
3x4 - 1.0 - 1.8 270
08.5 0.5
19.5 0.5 /
3x6 - 1.0 - 1.8 360
09.5 0.5
24.5 0.5 /
3 x 10 - 1.2 - 2.4 570
11.5 0.5
28.8 0.5 /
3 x 16 - 1.2 - 1.8 760
12.2 0.5
37.5 0.5 /
3 x 25 - 1.4 - 3.5 1250
16.0 0.5
38.5 1.0 /
3 x 35 - 1.4 - 2.4 1500
16.5 1.0
46.5 1.0 /
3 x 50 - 1.6 - 2.7 2180
19.5 1.0
16.2 0.3 /
4 G 1.5 - 0.8 - 1.6 170
06.5 0.2
19.0 0.3 /
4 G 2.5 - 0.9 - 1.6 240
07.0 0.2
23.0 0.5 /
4G4 - 1.0 - 1.8 350
08.2 0.5
25.0 0.5 /
4G6 - 1.0 - 1.9 450
09.0 0.5
30.0 0.5 /
4 G 10 - 1.2 - 1.9 690
10.5 0.5
38.0 0.5 /
4 G 16 - 1.2 - 2.0 1040
12.8 0.5
44.3 0.8 /
4 G 25 - 1.4 - 2.5 1490
14.5 0.8
48.5 1.0 / 1970
4 G 35 - 1.4 - 2.4
16.5 1.0

PRYSMIAN 2012, All Rights Reserved


All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian: any modification or
alteration afterwards of product may give different result.
The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without
the written consent of Prysmian. The information is believed to be correct at the time of issue. Prysmian reserves the right to amend this
specification without prior notice. This specification is not contractually valid unless specifically authorized by Prysmian.

Data Sheet No.: DB-S-044B2012en/JF www.prysmiangroup.com Issued 2013-07-11 YA/MK/ Page 3 of 4


Current ratings at 30C Cable Type TML
Max. Conductor temperature Max. short circuit temperature
90C 200 C 250 C
No. of loaded
conductors
3 3 1 3 - -
In Air
Tinned Plain
In Air contacted by In Water In Water
Conductor Conductor
walls or floors

- -
Nominal
Cross
sectionmm

Max. short circuit current (1s)-


mm Current ratings in ampere for an ambient temperature of 30C
kA
1 19 18 - 23 0,12 0,14
1,5 24 23 42 29 0,18 0,21
2,5 32 30 54 38 0,31 0,36
4 43 41 74 52 0,49 0,57
6 56 53 96 67 0,73 0,86
10 78 74 133 94 1,22 1,43
16 104 99 179 125 1,95 2,29
25 138 131 236 166 3,05 3,58
35 171 162 293 205 4,27 5,01
50 213 202 365 256 6,1 7,15
70 263 250 451 316 8,54 10
95 317 301 544 380 11,6 13,6
120 370 352 635 444 14,6 17,2
150 425 404 730 510 18,3 21,5
185 485 461 832 582 22,6 26,5
240 576 547 988 691 29,3 34,3
300 666 633 1142 799 36,6 42,9

*) The current ratings for use in water are valid for the installation in water with the total length. The calculated value is 20% higher
than the value of the installation in air.

Correction factor for ambient air temperatures other than 30C


Ambient temp. C 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
Conversion factor 1,18 1,14 1,10 1,05 1,00 0,95 0,89 0,84 0,77 0,71 0,63 0,55 0,45 0,41 0,29

Short circuit current capacities I thz for shut off time up to 5 s: Ithz = Ithr

PRYSMIAN 2012, All Rights Reserved


All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian: any modification or
alteration afterwards of product may give different result.
The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without
the written consent of Prysmian. The information is believed to be correct at the time of issue. Prysmian reserves the right to amend this
specification without prior notice. This specification is not contractually valid unless specifically authorized by Prysmian.

Data Sheet No.: DB-S-044B2012en/JF www.prysmiangroup.com Issued 2013-07-11 YA/MK/ Page 4 of 4