Escolar Documentos
Profissional Documentos
Cultura Documentos
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909
Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813
E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
99436 25/06/2017 JAPHET OMEFE FID, LEEA PART 1, NDT LEVEL II MT, PT &
UT
Identification Number Qty Description of Equipment TARE SWL Proof Date of next
WT GROSS Load Examination
WT Applied
GAS RACK
AL-SIL-08 1 A steel construction Gas Rack in 0.39 0.60 0.99 N/A 24/12/2017
dimensions 0.92m X 0.63m X Tonnes Tonnes Tonnes
2.01m (Length X Width X Height)
c/w 4 lifting points. 6.89
Sling#: tonnes
1set Fitted with 16mm X 1.5m X 4
SISL-098 @
Legged Wire Rope Sling c/w Quad
Master Link with ferrule secured 0-90o
Shackle #: thimble eyes all ends.
4.75
S1, S2, S3, S4 4pcs Bow Safety Pin Shackle tonnes
Comment: Back load item to onshore for load test
SPECIFICATION : BS 7072, BS 6210, BS 3032 TEST PROCEDURE: JOP-043
MPI METHOD: Wet Visible CONTRAST MEDIA: White Contrast Aid
PARTS EXAMINED: Four Lifting Points and Entire Body INDICATOR: Black Magnetic Ink
RESULTS: No defect as at the time of inspection. Fit for use
Name and address of equipment owner: Address of premises where Test / Examination was held:
Revision No: A02 Effective Date: 28th February 2017 Frm No: JCI-CERT-VMPI-RPT-001