Você está na página 1de 2

Technical Data Bulletin

ISD 1012000

Ionization Smoke Detector


The Ionization Smoke Detector is supplied
with the following standard features:
C Stable operation under extreme environmental conditions
C Dual Bi-color LED status indication
C Low-Profile design attractive, unobtrusive
C Conforms to U.L. Standard 268, latest edition
C Designed in accordance with NFPA Standard 72E
C FMRC approved
C Backward compatibility to preceding detector and base
designs

Description

% STATE-OF-THE-ART TECHNOLOGY % ARCHITECT/ENGINEER SPECIFICATIONS


The Chemetron Fire Systems Ionization Smoke Detector Early warning smoke detector shall be Chemetron Fire
features two bi-colored LEDs for status indication. In standby Systems detector stock number (see ordering information). It
the LEDs flash green once every second. When the detector shall operate on the ionization principle. The detector shall
senses smoke and goes into alarm, the LEDs latch on red. The consist of a dual chamber smoke sensing element with
detector is comprised of a patented dual chamber smoke sampling and reference chambers that use the same radioac-
sensing element utilizing advanced electronic circuitry. The tive source. Detectors shall be of low-profile design and shall
sensing chamber is unique in that a single radioactive source protrude from ceiling not more than 2 inches. Static shielding
ionizes both the reference and sample chambers. This provides shall protect against the operation interference of electrical
for stable operation over a wide air flow range. noise. The detector shall not be affected by pressure or
% SIMPLIFIED OPERATING PRECISION humidity changes. Detector head shall be fitted with locking
Advanced smoke chamber design is enhanced by the use pin that requires an uncommon tool for removal from its
of high quality components. Automated assembly and 100% base.
functional testing assure uniform operation. Each detector The head shall incorporate dual pulsing green LEDs as an
contains an alarm LED that pulses in the standby mode when indication of power at the detector head. The dual LED shall
power is present. In an alarm condition, the LED illuminates illuminate steadily on red to provide a positive indication when
steadily to pinpoint the location of the triggered detector. the detector is in the alarm condition. Wiring shall be accom-
% SIMPLIFIED TESTING plished by using screw terminals.
Testing is easy and reliable. A built-in reed switch permits Positive, convenient testing shall be provided by a built-in
the detector to be test-activated by an external magnet. This reed switch, permitting activation by an external magnet,
simple magnet test simulates activation by smoke at a level simulating activation by smoke.
between 4% and 6% obscuration. This magnet test is especially The base shall be capable of being used with both ioniza-
useful in environmentally unstable or clean areas. tion and photoelectric detector heads. An optional relay base
% ADDITIONAL FUNCTIONS OPTIONAL shall permit detectors to activate additional devices such as
An optional relay base is available to permit the smoke remote alarms, door closers, etc.
detector to activate additional devices such as remote visual
and audible alarms, door closers, etc. The compact relay
module fits into the detector junction box.

Ordering Information

Shipping Weight
Stock Number Description lbs (kg)
70100911 Ionization Detector head with 43 mA Standard Base .5 (.23)
70100912 Ionization Detector head with 43 mA Relay Base 1 (.45)
70100913 Ionization Detector head with 93 mA Base .5 (.23)

Você também pode gostar