The Company
ERICO was formed in 1903 as the Electric Railway Improvement Company. In 1938
ERICO developed the CADWELD exothermic welding process which has found industry
wide acceptance as the ultimate electrical connection. During the 1970s, ERICO pio-
neered the development and standardization of the copper bonded steel grounding
electrode. Since that time, ERICOs dominance as the worlds leading supplier of
grounding products has seen its expansion into many related industries. Most recently,
ERICO acquired Global Lightning Technologies (Australia), Sudafix (UK) and AC
Lightning Security Inc. (USA), all leading manufacturers of lightning and surge protection
products. The synergy of these mergers has positioned ERICO as the largest global
supplier of lightning protection solutions and products under the trade names:
Noting that there is no single technology that can eliminate the harmful effects of lightning or induced
surge transients, ERICO Inc. has developed its generic Six Point Plan of protection. The concept behind
this plan is to prompt the user to consider a holistic and coordinated approach to lightning protection,
one embracing all aspects of potential damage. This ranges from the more obvious direct strike to the
more subtle mechanisms of differential earth potential rises and voltage induction at service entry points.
The six interdependent disciplines that form the protection plan are:
www.erico.com
Table Of Contents
Series 700 Ground Rods & Plates, Guards & Accessories .......... 44-46
www.erico.com 1
Six Point Plan of Protection
Figure 1.
2 www.erico.com
Six Point Plan of Protection
www.erico.com 3
The Need for Lightning Protection
4 www.erico.com
The Need for Lightning Protection
Figure 2. Typical positive and negative charge distribution in Figure 5. Electric field due to downleader increases to the Figure 6. Upward leaders propagate toward downward
the cumulonimbus cloud. point of initiation of an upward leader. leader to complete the ionized path between cloud and
ground.
www.erico.com 5
The Need for Lightning Protection
6 www.erico.com
The Need for Lightning Protection
Summary
It is important to realize that inefficiency in the design of any one of the above components
represents an inefficiency in the protection system as a whole. Each of these components
must be considered independently and finally integrated together to form the complete
lightning protection system. Indeed, without such integration, there is limited protection.
www.erico.com 7
General Installation Notes
1. The design layout and installation details shown 11. No bend of a conductor shall form a final included
hereon shall meet the requirements of National Fire angle of less than 90 degrees nor shall have a radius
Protection #780 current edition. of bend of less than 8.
2. Connection to ground rod or ground loop conductor 12. Conductors shall interconnect all air terminals and
shall be made at a point not less than 18 below shall form a two-way path from each air terminal
grade, ground rods shall not be less than 8' long and horizontally or downward to connections with
extend at least 10' into the earth. ground terminals, with the exception of vertical roof
members, upper roof to lower roof transitions, or
3. Air terminals shall be placed at all unprotected lower roof "dead ends".
outside corners and located intermediately on 20-0
maximum spacing around the roof perimeter or ridge 13. All lightning protection conductors shall be fastened
and within 2-0 of outside edge. not more than 3-0 maximum spacing.
4. Midroof areas are to be provided with air terminals 14. All adhesive type fittings shall be set in place with an
spaced either at 50 center or, of sufficient quantity application of compatible adhesive compound before
and height, to ensure the entire roof area is covered roof gravel is applied.
by a zone-of-protection as afforded by a 150
radius sphere, per NFPA #780. 15. Actual jobsite conditions may necessitate slight
alterations in air terminal and ground rod locations.
5. Grounded metal bodies located about the structure
such as: soil pipe vents, roof drains, exhaust fans, air 16. Bare copper lightning protection materials shall not
handling units, any miscellaneous equipment with be installed on aluminum roof or siding or other alu-
electrical services, etc. shall be interconnected to the minum surfaces and vice versa, aluminum lightning
lightning conductor system, if within the bonding protection materials shall not be installed on copper
distance established by NFPA #780. roofing or copper siding or other copper surfaces.
6. Bond all metallic pipes including water, fire, gas, 17. Surge suppressor shall be provided on electric and
sewer, storm, etc. which enter the structure, within telephone service entrances and on radio and
12 of grade, to the nearest downlead, ground rod, television antenna lead-ins.
or ground loop.
18. Seal ends of conduit moisture tight with duct seal
7. All reinforcing, structural, framing, and miscellaneous or lead wedge. All conduit, conduit fasteners, and
steel shall be made electrically continuous throughout miscellaneous accessories shall be furnished and
construction by welding, clipping, bolting, or other installed by the electrical contractor.
approved methods.
19. The design layout and installation details shown
8. Telephone and/or electric service entrance grounds hereon shall meet the requirements of Underwriters
shall be interconnected to one lightning protection Laboratories Standard 96A for Master Labeled
ground or water pipe. lightning protection systems. When desired, the
actual Master Label will be delivered upon comple-
9. All areas which have not been provided with tion of installation.
lightning protection components are protected from
higher roofs or structures. These areas fall within a 20. The lightning protection installation shall comply in
zone-of-protection as established by the current all respects to Lightning Protection Institute Standard
edition of the NFPA #780 document for protection 175. The installation shall be made by or under the
against lightning. supervision of an L.P.I. Certified Master Installer.
10. The lightning protection system shall be installed 21. Metal bodies of inductance located about the roof
in a neat and inconspicuous manner so that all such as metal flashing, gravel stops, roof drains, soil
components will blend with the appearance of pipe vents, insulation vents, louvers, and door frames
the building. situated within 6-0 of a lightning conductor or
bonded metal body shall be interconnected to the
lightning conductor system.
8 www.erico.com
Isometric View of Cable Lightning Protection Layout
Legend
No. LPC151 Copper Secondary Bonding Wire
Air Terminal Location (#6 AWG)
No. LPC126 Copper Cable (Min. Class II Cable) Above Finished Grade
0' Grade
www.erico.com 9
Typical Installation Drawings
Adhesive type
point base
Point Base
Point base
Parallel
Adhesive type combination
cable holder cable splicer
Adhesive type
point base
Adhesive type
cable holder
10 www.erico.com
Typical Installation Drawings
Typical Thru-Roof
Connection
Washer & nut
Cable connection
Flashing clamp
Flashing collar
Flashing boot
Threaded rod,
rod length
determined by
Thru-roof cable connecting assembly, roof thickness
furnished with EPDM pipe flashing and
1/2" dia. x 18" all thread rod
Washer & nut
Cast cable to steel bonding clamp Cable connection
Washer & nut
1" PVC conduit
www.erico.com 11
Typical Installation Drawings
Cast pipe
bonding clamp
Cast parallel
combination cable splicer
Cast bronze
Adjustable pipe to aluminum
bonding strap bimetallic
cable splicer
12 www.erico.com
Typical Installation Drawings
Typical Secondary
Equipment Bond
Schematic View:
Typical Cable
*
Routing at Cast terminal bonding
Equipment lug. Secure with
stainless steel machine
screw and stainless
steel nut.
** 1'-4" max.
Typical
Ladder/Equipment
Frame Bond
** 1'-4" max.
Greater than 4'-0" Greater than 4'-0"
Not to exceed 20'-0" Not to exceed 20'-0"
Main size conductor
** 1'-4" max. ** 1'-4" max.
Cast bonding lug.
Secure with stainless
steel machine screw
and stainless steel nut.
90 min.
* NOTE: Per NFPA, where only one strike
termination device is required on a chimney
or vent, at least one main sized conductor ACCEPTABLE
(no longer than 16') shall connect the strike
termination device to a main conductor at 8" Less Than Radius 8" Radius
90
** NOTE: Distance of 1'-4" determined
Less Than 90
from provided point within 2'-0" of outside
corner at 90
NOT ACCEPTABLE NOT ACCEPTABLE
www.erico.com 13
General Specification System 2000
14 www.erico.com
General Specification System 2000
www.erico.com 15
Conductors System 2000 Series 100
Smooth Weave
Ropelay
Conc. Strand
16 www.erico.com
Conductors System 2000 Series 100
www.erico.com 17
Points & Accessories System 2000 Series 200
3/8 POINTS
COPPER (Class I)
NICKEL
PLATED BARE
NICKEL BARE SAFETY SAFETY LEAD
LENGTH PLATED TIP* TIP* COATED
10 LPC201 LPC201B LPC201ST LPC201BST LPC201L
12 LPC202 LPC202B LPC202ST LPC202BST LPC202L
15 LPC203 LPC203B LPC203ST LPC203BST LPC203L
18 LPC204 LPC204B LPC204ST LPC204BST LPC204L
24 LPC205 LPC205B LPC205ST LPC205BST LPC205L
30 LPC206 LPC206B LPC206ST LPC206BST LPC206L
36 LPC207 LPC207B LPC207ST LPC207BST LPC207L
48 LPC208 LPC208B LPC208ST LPC208BST LPC208L
1/2 POINTS
COPPER ALUMINUM
(Class II) (Class I)
NICKEL
PLATED BARE
NICKEL BARE SAFETY SAFETY LEAD BARE SAFETY
LENGTH PLATED TIP* TIP* COATED TIP*
10 LPC221 LPC221B LPC221ST LPC221BST LPC221L LPA221B LPA221ST
12 LPC222 LPC222B LPC222ST LPC222BST LPC222L LPA222B LPA222ST
15 LPC223 LPC223B LPC223ST LPC223BST LPC223L LPA223B LPA223ST
18 LPC224 LPC224B LPC224ST LPC224BST LPC224L LPA224B LPA224ST
24 LPC225 LPC225B LPC225ST LPC225BST LPC225L LPA225B LPA225ST
30 LPC226 LPC226B LPC226ST LPC226BST LPC226L LPA226B LPA226ST
36 LPC227 LPC227B LPC227ST LPC227BST LPC227L LPA227B LPA227ST
48 LPC228 LPC228B LPC228ST LPC228BST LPC228L LPA228B LPA228ST
5/8 POINTS
COPPER ALUMINUM
(Class II) (Class II)
NICKEL
PLATED BARE
NICKEL BARE SAFETY SAFETY LEAD BARE SAFETY
LENGTH PLATED TIP* TIP* COATED TIP*
10 LPC241 LPC241B LPC241ST LPC241BST LPC241L LPA241B LPA241ST
12 LPC242 LPC242B LPC242ST LPC242BST LPC242L LPA242B LPA242ST
15 LPC243 LPC243B LPC243ST LPC243BST LPC243L LPA243B LPA243ST
18 LPC244 LPC244B LPC244ST LPC244BST LPC244L LPA244B LPA244ST
24 LPC245 LPC245B LPC245ST LPC245BST LPC245L LPA245B LPA245ST
30 LPC246 LPC246B LPC246ST LPC246BST LPC246L LPA246B LPA246ST
36 LPC247 LPC247B LPC247ST LPC247BST LPC247L LPA247B LPA247ST
48 LPC248 LPC248B LPC248ST LPC248BST LPC248L LPA248B LPA248ST
NOTE: Points are manufactured to UL Requirements
* Recommended safety tip for safety, performance, and value.
18 www.erico.com
Points & Accessories System 2000 Series 200
EXTENSION RODS
DIAMETER COPPER ALUMINUM STAINLESS
3/8 LPC271CTO
1/2 LPC272CTO LPA272CTO
5/8 LPC273CTO LPA273CTO LPS273CTO
STANDARD N.C. THREAD EACH END
CTO - State length required
Extension rods available up to 120"
www.erico.com 19
Points & Accessories System 2000 Series 200
20 www.erico.com
Point Bases, Braces, and Accessories System 2000 Series 300
www.erico.com 21
Point Bases, Braces, and Accessories System 2000 Series 300
Bronze or Aluminum Cast Pipe Mount point base SERIES 330 (suit pipe O.D. 1.315 - 1.9)
for vertical pipe or mast. Bronze bases lead dipped Point Dia. Copper Aluminum
for use on dissimilar metals. May be used with or 3/8 LPC33038 -
without cable run on pipe or will allow point to 1/2 LPC33012 LPA33012
stand off pipe to use type 321 point to cable 5/8 LPC33058 LPA33058
connector. Available for all points 3/8, 1/2 and
5/8 diameter. For pipe sizes greater than 2-1/2"
O.D., refer to Series 596.
SERIES 331 (suit pipe O.D. 1.75 - 2.5)
Point Dia. Copper Aluminum
3/8 LPC33138 -
1/2 LPC33112 LPA33112
5/8 LPC33158 LPA33158
Bronze or Aluminum Cast Pipe Mount point base SERIES 332 (suit pipe O.D. 1.315 - 1.9)
with point coupling for horizontal pipe. Bronze Point Dia. Copper Aluminum
bases lead dipped for use on dissimilar metals. 3/8 LPC33238 -
May be used with or without cable run on 1/2 LPC33212 LPA33212
pipe. Available for all points 3/8, 1/2 and 5/8 5/8 LPC33258 LPA33258
diameter. For pipe sizes greater than 2-1/2" O.D.,
refer to Series 596.
SERIES 333 (suit pipe O.D. 1.75 - 2.5)
Point Dia. Copper Aluminum
3/8 LPC33338 -
1/2 LPC33312 LPA33312
5/8 LPC33358 LPA33358
22 www.erico.com
Point Bases, Braces, and Accessories System 2000 Series 300
www.erico.com 23
Point Bases, Braces, and Accessories System 2000 Series 300
Galvanized Steel Tripod Braces for additional SERIES 350 - SERIES 354
support of long air terminals. Constructed of
1/4 mild steel with heavy section washer guides.
PENETRATING BASE
All joints welded prior to galvanizing. Two PART # LENGTH UP TO MAX.
mounting holes per leg furnished for installation. POINT SIZE
Available for all 1/2 and 5/8 diameter points. LPG35012 14 1/2 X 24
LPG35058 14 5/8 X 24
LPG35112 18 1/2 X 30
LPG35158 18 5/8 X 30
LPG35212 24 1/2 X 40
LPG35258 24 5/8 X 40
LPG35312 36 1/2 X 60
LPG35358 36 5/8 X 60
LPG35412 48 1/2 X 84
LPG35458 48 5/8 X 84
Galvanized Steel Tripod Braces for additional SERIES 360 - SERIES 364
support of long air terminals on flat or gently
sloping surface when no penetration may be
NON-PENETRATING BASE
made for anchoring. Constructed of 1/4 mild PART # LENGTH UP TO MAX.
steel with heavy section washer guides. All joints POINT SIZE
welded prior to galvanizing. For use with hot LPG36012 14 1/2 X 24
pitch, roofing compound or commercial adhesive LPG36058 14 5/8 X 24
on membrane surface or other locations. Available LPG36112 18 1/2 X 30
for all 1/2 and 5/8 diameter points. LPG36158 18 5/8 X 30
LPG36212 24 1/2 X 40
LPG36258 24 5/8 X 40
LPG36312 36 1/2 X 60
LPG36358 36 5/8 X 60
LPG36412 48 1/2 X 84
LPG36458 48 5/8 X 84
24 www.erico.com
Industrial Stack Equipment System 2000 Series 400
COPPER CABLES
PART # CONDUCTOR # OF WIRE SIZE WEIGHT PER CIRCULAR MEETS
TYPE STRANDS GAUGE 1000 FEET MILS REQMENT
LPC401 ROPELAY 28 14 380 Lbs. 115,080 CLASS II
LPC404 CONCENTRIC 19 0.1055 653 Lbs. 211,600 CLASS II 4/0
LEAD COVERED COPPER CABLES With a continuous 1/16 pure lead sheath.
PART # CONDUCTOR # OF WIRE SIZE WEIGHT PER CIRCULAR MEETS
TYPE STRANDS GAUGE 1000 FEET MILS REQMENT
LPLC401 CONCENTRIC 28 14 1,380 Lbs. 115,080 CLASS II
LPLC404 CONCENTRIC 19 0.1055 1,983 Lbs. 211,600 CLASS II 4/0
Note: All conductors listed on this page are manufactured to Underwriters Laboratories requirements.
Note: Specialty copper cables are available on request to meet specific job requirements. Please call for pricing and availability.
www.erico.com 25
Industrial Stack Equipment System 2000 Series 400
POINT BASES Note: Standard stud length 7/8 for insert, drop-in or caulk-in
PART # MATERIAL POINT STUD* anchors. For expansion shield anchor special 1-1/2 stud
THREAD LENGTH length required specify LONG.
SERIES 431
LPC431 BARE BRASS 5/8 Note: Current standard requirements specify that side mounted
LPLC431 LEAD COATED 5/8 points be anchored at two locations to the structure with
the above provided stud counting as one. Refer to part
SERIES 433 numbers LP-C480, LP-LC480, LP-C492 or LP-LC492 for
LPC433 BARE BRASS 5/8 point holders to be used as the second required anchor.
LPLC433 LEAD COATED 5/8
Note: Current standard requirements state that top mounted
SERIES 435 air terminals shall not extend over 18 above the stack.
LPC435SH BARE BRASS 5/8 7/8
LPC435LG BARE BRASS 5/8 1-1/2
LPLC435SH LEAD COATED 5/8 7/8
LPLC435LG LEAD COATED 5/8 1-1/2
SERIES 436
LPC436SH BARE BRASS 5/8 7/8
LPC436LG BARE BRASS 5/8 1-1/2
LPLC436SH LEAD COATED 5/8 7/8
LPLC436LG LEAD COATED 5/8 1-1/2
SERIES 431 SERIES 433 SERIES 435
SERIES 437
LPC437SH BARE BRASS 5/8 7/8
LPC437LG BARE BRASS 5/8 1-1/2
LPLC437SH LEAD COATED 5/8 7/8
LPLC437LG LEAD COATED 5/8 1-1/2
CABLE SPLICERS
SERIES 441 SERIES 443
STRAIGHT
PARALLEL SPLICE MATERIAL
LPC441 LPC443 BARE BRASS
LPC44140 LPC44340 BARE BRASS
LPLC441 LPLC443 LEAD COATED
SERIES 441 SERIES 443
LPLC44140 LPLC44340 LEAD COATED
1/16" lead coating.
26 www.erico.com
Industrial Stack Equipment System 2000 Series 400
BONDING FITTINGS
CONTACT FOR USE WITH
SERIES 451 MATERIAL AREA CABLE No.
LPC451 BARE BRASS 3 IN2 LPC401
LPC45140 BARE BRASS 3 IN2 LPC451
LPLC451 LEAD COATED 3 IN2 LPC401
LPLC45140 LEAD COATED 3 IN2 LPC404
LPS451 TYPE 316 SS 3 IN2 LPC401 or LPLC401
LPS45140 TYPE 316 SS 3 IN2 LPC404 or LPLC404
LPS451X TYPE 316 SS 8 IN2 LPC401 or LPLC401
LPS451X40 TYPE 316 SS 8 IN2 LPC404 or LPCL404
Standard bolt hole size = 13/16.
Contact ERICO for other sizes.
1/16" lead coating.
For 4/0 cable size insert "40" following 464 in the part number.
eg. LPS4644058 for stainless steel lug, 4/0 cable size, 5/8" point.
SERIES 465
ASSEMBLY COMPONENTS
LUG CONNECTOR CONNECTOR
PART # LUG MATERIAL MATERIAL
LPC465 LPC451 BARE BRASS LPC441 BARE BRASS
LPS465 LPS451 STAINLESS LPLC441 LEAD COATED
LPLC465 LPLC451 LEAD COATED LPLC441 LEAD COATED
Notes: Standard bolt hole size = 13/16. Contact ERICO for other hole sizes.
Standard cable length = 36. Contact ERICO for other lengths.
For 4/0 cable size insert "40" following 465 in the part number.
eg. LPS4654058 for stainless steel lug, 4/0 cable size, 5/8" point.
www.erico.com 27
Industrial Stack Equipment System 2000 Series 400
SERIES 466
Cast Bronze universal cable to rebar bonding clamp.
Fits cable sizes through 250 MCM to reinforcing bars
up through #9 (1.128").
PART #
LPC466
LPLC468
Lead covered brass; connect Part No. LPC467
flush rebar to Part No. LPLC401 and LPC404
lead covered copper downlead cable
NOTE: The above iron band yokes are designed to fit over a single 3/8 thick band.
In locations where cables must cross or interconnect a band overlapped joint
specify Part No. as follows: LPG469X Double or LPS469X Double.
28 www.erico.com
Industrial Stack Equipment System 2000 Series 400
www.erico.com 29
Industrial Stack Equipment System 2000 Series 400
30 www.erico.com
Industrial Stack Equipment System 2000 Series 400
LPS48458
Stainless steel welded; provided with 5/8"-11
internal thread
Stainless Steel
LPS48434
Cast type 316L stainless steel; provided with
3/4"-10 internal thread
Cast Type 316L Stainless Steel
SERIES 486
Provided with 1/2-13 internal thread. Mounts
in drilled hole 7/8 diameter x 1-3/4 depth.
Use extra length stud products 1-1/2 Long.
Preferred anchoring method for brick chimney.
www.erico.com 31
Industrial Stack Equipment System 2000 Series 400
LPC4944/0
Bare bronze, for use with Part No.
LPC404 bare 4/0 copper cable
LPC49540
Bare bronze, for use with Part No.
LPC404 bare 4/0 copper cable
LPC49640
Bare bronze, for use with Part No.
LPC404 bare 4/0 copper cable
32 www.erico.com
Clamps, Splices, Plates, & Lugs System 2000 Series 500
www.erico.com 33
Clamps, Splices, Plates, & Lugs System 2000 Series 500
34 www.erico.com
Clamps, Splices, Plates, & Lugs System 2000 Series 500
Series 540
LPC540 for copper cables to compatible
metal surface
LPC540L for copper cables to dissimilar
metal surface
Series 537 Series 540 LPA540 for aluminum cables to compatible
3 square inches 8 square inches metal surface
of contact surface. of contact surface.
Series 552
Series 551 Compression type fingers to
Bolt tension grip on cable crimp over cable for Class I
for Class I or II installations installations only
www.erico.com 35
Clamps, Splices, Plates, & Lugs System 2000 Series 500
Series 559
Series 557
Provides bolt tension contact.
Gives 8 square inches of bolt
Draws tight on member thick-
tension contact. Draws tight
ness up to 5/8
on member thickness up to 1
36 www.erico.com
Clamps, Splices, Plates, & Lugs System 2000 Series 500
Series 599
BI-METALLIC LPC599A for aluminum to copper cables
BONDING PLATE
SERIES 599 Aluminum
Bi-metallic bonding plate suitable for the
connection of either aluminum or copper
cables. Aluminum plate bonds direct to Stainless
surface requiring bonding, typically A/C
duct or housing, bond can then be made
with either copper or aluminum cable. Copper
Aluminum
www.erico.com 37
Thru-Roofs, -Walls, & Special Purpose Parts System 2000 Series 600
38 www.erico.com
Thru-Roofs, -Walls, & Special Purpose Parts System 2000 Series 600
Series 620
Series 621
Series 622
Series 628
www.erico.com 39
Thru-Roofs, -Walls, & Special Purpose Parts System 2000 Series 600
40 www.erico.com
Thru-Roofs, -Walls, & Special Purpose Parts System 2000 Series 600
Series
665NC
www.erico.com 41
Thru-Roofs, -Walls, & Special Purpose Parts System 2000 Series 600
SERIES 681
Cast bronze aircraft type static grounding
receptacle for mounting on a vertical surface.
Furnished with standard pin connection,
chain retained cover plate and spring clip to
secure cover plate when installed on a vertical Series 681
surface. Install flush with finished wall surface.
Designed to couple directly to 3/4 support
rod.
42 www.erico.com
Thru-Roofs, -Walls, & Special Purpose Parts System 2000 Series 600
www.erico.com 43
Ground Rods & Plates, Guards & Accessories System 2000 Series 700
44 www.erico.com
Ground Rods & Plates, Guards & Accessories System 2000 Series 700
www.erico.com 45
Ground Rods & Plates, Guards & Accessories System 2000 Series 700
46 www.erico.com
Fasteners System 2000 Series 800
Series 810
Copper or aluminum. Compression
type fingers crimped over cable.
www.erico.com 47
Fasteners System 2000 Series 800
SLATING NAIL LPC841 copper ring shank SHEET METAL LPS846 stainless steel hex
slating nail, 1-3/4 long pan-head sheet metal
SERIES 841 SCREW screw #10 x 5/8
LPA841 large aluminum
nail, 6d
SERIES 846 & 847 LPS846X stainless steel hex
pan-head self-drilling
LPG841 large galvanized tek screw #10 x 5/8
nail, 6d
LPS847 stainless steel hex
LPS841 stainless steel ring pan-head sheet metal
shank nail, 2-1/2 long screw #10 x 1
48 www.erico.com
Fasteners System 2000 Series 800
TOGGLE BOLT LPG848 galvanized steel DRIVE-IN LPP857 one-piece lead drive-In
toggle bolt, 1/4 x 3 anchor with stainless
SERIES 848 & 849 ANCHOR steel nail, 1/4 x 1-1/4
LPG849 galvanized steel
toggle bolt, 1/4 x 4
SERIES 857
STAINLESS STEEL
LENGTH 1/4-20 5/16-18 3/8-16 1/2-13
1/2" LPS860
3/4" LPS861 LPS865 LPS868
1" LPS862 LPS866 LPS869 LPS871
1-1/4" LPS863
1-1/2" LPS864 LPS867 LPS870 LPS872
2" LPS873
www.erico.com 49
Fasteners System 2000 Series 800
ADHESIVES LPP899LN
30 oz. Liquid NailsTM
SERIES 899LN
A fast drying waterproof synthetic rubber and resin-based adhesive.
Standard size 30 oz. Cartridge. Will adhere 20- Part No. 309 adhesive
bases, or 40- No. 809 or No. 810 adhesive cable holders to built-up surface.
For metal roofs, which cannot be penetrated, will adhere 30- Part No. 309
or 60 No. 809 or No. 810 cable holders. Do not apply at temperatures Liquid Nails is a trademark
below 10 F. Do not use on single-ply membrane roofing systems.* of Glidden Company
*Improper selection of adhesive on roofing can cause serious deterioration to the roofing. Always verify compatibility of
adhesive with roofing contractor and/or manufacturer.
50 www.erico.com
Ornaments & Insulators System 2000 Series 900
www.erico.com 51
52 www.erico.com