Você está na página 1de 28

Column location GF grid J/4

u 4200 mm
D 650 mm
cover 50 mm
dom 600 mm
f'c 50 Mpa
P/A 1.3 MPa
x (smallest) 300 mm
y (largest) 600 mm
bh (ratio of y & x) = y/x 2.0
dim. Of the critical shear perimeter measured // to the direction of M*v , a 600 mm (Also refer AS3600 Fig. 9.2.1 (B)
fcv 2.40 MPa AS3600 Cl. 9.2.3
Overall depth of Col. In the plane of B. Moment 0.30 m --> Eg. About y-y axis, My* -> d = eff. depth measure along or // to x axis
Min M* 75.45 kNm AS3600 Cl 10.1.2
M*v from RAPT 0.00 kNm with 100% column stiffness
M*v = larger of the 2 above = 75 kNm
V* 5030 kN
Cl.9.2.3 Ultimate shear strength where M*v = 0
Shear head 0 (1 = Yes, 0 = No)
Vuo (without shear head) 7041 kN AS3600 Eqnt 9.2.3(1)
Vuo (with shear head) 9892 kN AS3600 Eqnt 9.2.3(2)
Vuo 7041 kN
Cl.9.2.4 Ultimate shear strength where M*v is not 0
Ligs 0 (1 = Yes, 0 = No)
(a) No Closed ligs:
Vu = Vuo/[1+uM*v/(8V*adom)] 6891 kN AS3600 Eqnt 9.2.4(1)

Closed ligs provided:


(b) AS3600 Eqnt 9.2.4(2)_Torsion strip
Vu.min= 1.2Vuo/[1+uM*v/(2V*a2)] 7770 kN

Vu= Vu.min[(Asw/s)/(0.2y1/fsy.f)]^0.5................AS3600 Eqnt 9.2.4(4) 11680 kN < Vumax 16482 kN AS3600 Eqnt 9.2.4(5)
Asw 113 mm2
s 250 mm
y1 500 mm

Vu 6891 kN

Vu 6891
F 0.7
FVu 4823 kN Upper limit to Punching shear is exdceeded
e along or // to x axis
-4.1 %
Column location GF grid G/3

u 3600 mm
D 500 mm
cover 50 mm
dom 450 mm
f'c 40 Mpa
P/A 1.3 MPa
x (smallest) 300 mm
y (largest) 600 mm
bh (ratio of y & x) = y/x 2.0
dim. Of the critical shear perimeter measured // to the direction of M*v , a 600 mm (Also refer AS3600 Fig. 9.2.1 (B)
fcv 2.15 MPa AS3600 Cl. 9.2.3
Overall depth of Col. In the plane of B. Moment 0.30 m --> Eg. About y-y axis, My* -> d = eff. depth measure along or // to x axis
Min M* 33.00 kNm AS3600 Cl 10.1.2
M*v from RAPT 0.00 kNm with 100% column stiffness
M*v = larger of the 2 above = 33 kNm
V* 2200 kN
Cl.9.2.3 Ultimate shear strength where M*v = 0
Shear head 0 (1 = Yes, 0 = No)
Vuo (without shear head) 4115 kN AS3600 Eqnt 9.2.3(1)
Vuo (with shear head) 5755 kN AS3600 Eqnt 9.2.3(2)
Vuo 4115 kN
Cl.9.2.4 Ultimate shear strength where M*v is not 0
Ligs 0 (1 = Yes, 0 = No)
(a) No Closed ligs:
Vu = Vuo/[1+uM*v/(8V*adom)] 4015 kN AS3600 Eqnt 9.2.4(1)

Closed ligs provided:


(b) AS3600 Eqnt 9.2.4(2)_Torsion strip
Vu.min= 1.2Vuo/[1+uM*v/(2V*a2)] 4594 kN

Vu= Vu.min[(Asw/s)/(0.2y1/fsy.f)]^0.5................AS3600 Eqnt 9.2.4(4) 6906 kN < Vumax 9745 kN AS3600 Eqnt 9.2.4(5)
Asw 113 mm2
s 250 mm
y1 500 mm

Vu 4015 kN

Vu 4015
F 0.7
FVu 2810 kN Upper limit to Punching shear not exceeded
e along or // to x axis
27.7 %
Column location L1 edge columns with vertical pipe peno

u 1350 mm
D 500 mm
cover 50 mm
dom 450 mm
f'c 40 Mpa
P/A 0.7 MPa
x (smallest) 300 mm
y (largest) 600 mm
bh (ratio of y & x) = y/x 2.0
dim. Of the critical shear perimeter measured // to the direction of M*v , a 300 mm (Also refer AS3600 Fig. 9.2.1 (B)
fcv 2.15 MPa AS3600 Cl. 9.2.3
Overall depth of Col. In the plane of B. Moment 0.60 m --> Eg. About y-y axis, My* -> d = eff. depth measure along or // to x axis
Min M* 16.80 kNm AS3600 Cl 10.1.2
M*v from RAPT 35.00 kNm with 100% column stiffness
M*v = larger of the 2 above = 35 kNm
V* 560 kN
Cl.9.2.3 Ultimate shear strength where M*v = 0
Shear head 0 (1 = Yes, 0 = No)
Vuo (without shear head) 1434 kN AS3600 Eqnt 9.2.3(1)
Vuo (with shear head) 2049 kN AS3600 Eqnt 9.2.3(2)
Vuo 1434 kN
Cl.9.2.4 Ultimate shear strength where M*v is not 0
Ligs 0 (1 = Yes, 0 = No)
(a) No Closed ligs:
Vu = Vuo/[1+uM*v/(8V*adom)] 1330 kN AS3600 Eqnt 9.2.4(1)

Closed ligs provided:


(b) AS3600 Eqnt 9.2.4(2)_Torsion strip
Vu.min= 1.2Vuo/[1+uM*v/(2V*a2)] 1172 kN

Vu= Vu.min[(Asw/s)/(0.2y1/fsy.f)]^0.5................AS3600 Eqnt 9.2.4(4) 1761 kN < Vumax 2485 kN AS3600 Eqnt 9.2.4(5)
Asw 113 mm2
s 250 mm
y1 500 mm

Vu 1330 kN

Vu 1330
F 0.7
FVu 931 kN Upper limit to Punching shear not exceeded
e along or // to x axis
66.3 %
Column location L1 grid H/4

u 4241 mm
D 500 mm
cover 50 mm
dom 450 mm
f'c 40 Mpa
P/A 0.7 MPa
x (smallest) 450 mm
y (largest) 450 mm
bh (ratio of y & x) = y/x 1.0
dim. Of the critical shear perimeter measured // to the direction of M*v , a 450 mm (Also refer AS3600 Fig. 9.2.1 (B)
fcv 2.15 MPa AS3600 Cl. 9.2.3
Overall depth of Col. In the plane of B. Moment 0.45 m --> Eg. About y-y axis, My* -> d = eff. depth measure along or // to x axis
Min M* 81.00 kNm AS3600 Cl 10.1.2
M*v from RAPT 410.00 kNm with 100% column stiffness
M*v = larger of the 2 above = 410 kNm
V* 3600 kN
Cl.9.2.3 Ultimate shear strength where M*v = 0
Shear head 0 (1 = Yes, 0 = No)
Vuo (without shear head) 4505 kN AS3600 Eqnt 9.2.3(1)
Vuo (with shear head) 6436 kN AS3600 Eqnt 9.2.3(2)
Vuo 4505 kN
Cl.9.2.4 Ultimate shear strength where M*v is not 0
Ligs 1 (1 = Yes, 0 = No)
(a) No Closed ligs:
Vu = Vuo/[1+uM*v/(8V*adom)] 3470 kN AS3600 Eqnt 9.2.4(1)

Closed ligs provided:


(b) AS3600 Eqnt 9.2.4(2)_Torsion strip
Vu.min= 1.2Vuo/[1+uM*v/(2V*a2)] 2465 kN

Vu= Vu.min[(Asw/s)/(0.2y1/fsy.f)]^0.5................AS3600 Eqnt 9.2.4(4) 7396 kN < Vumax 7396 kN AS3600 Eqnt 9.2.4(5)
Asw 200 mm2
s 100 mm
y1 500 mm

Vu 7396 kN

Vu 7396
F 0.7
FVu 5177 kN Upper limit to Punching shear not exceeded
e along or // to x axis
43.8 %
Column location L1 grid D/4

u 3600 mm
D 500 mm
cover 50 mm
dom 450 mm
f'c 40 Mpa
P/A 1.3 MPa
x (smallest) 300 mm
y (largest) 600 mm
bh (ratio of y & x) = y/x 2.0
dim. Of the critical shear perimeter measured // to the direction of M*v , a 300 mm (Also refer AS3600 Fig. 9.2.1 (B)
fcv 2.15 MPa AS3600 Cl. 9.2.3
Overall depth of Col. In the plane of B. Moment 0.30 m --> Eg. About y-y axis, My* -> d = eff. depth measure along or // to x axis
Min M* 50.40 kNm AS3600 Cl 10.1.2
M*v from RAPT 150.00 kNm with 100% column stiffness
M*v = larger of the 2 above = 150 kNm
V* 3360 kN
Cl.9.2.3 Ultimate shear strength where M*v = 0
Shear head 0 (1 = Yes, 0 = No)
Vuo (without shear head) 4115 kN AS3600 Eqnt 9.2.3(1)
Vuo (with shear head) 5755 kN AS3600 Eqnt 9.2.3(2)
Vuo 4115 kN
Cl.9.2.4 Ultimate shear strength where M*v is not 0
Ligs 1 (1 = Yes, 0 = No)
(a) No Closed ligs:
Vu = Vuo/[1+uM*v/(8V*adom)] 3582 kN AS3600 Eqnt 9.2.4(1)

Closed ligs provided:


(b) AS3600 Eqnt 9.2.4(2)_Torsion strip
Vu.min= 1.2Vuo/[1+uM*v/(2V*a2)] 2609 kN

Vu= Vu.min[(Asw/s)/(0.2y1/fsy.f)]^0.5................AS3600 Eqnt 9.2.4(4) 5534 kN < Vumax 5534 kN AS3600 Eqnt 9.2.4(5)
Asw 113 mm2
s 100 mm
y1 500 mm

Vu 5534 kN

Vu 5534
F 0.7
FVu 3874 kN Upper limit to Punching shear not exceeded
e along or // to x axis
15.3 %
Column location L1 grid F/4

u 3600 mm
D 500 mm
cover 50 mm
dom 450 mm
f'c 40 Mpa
P/A 1.3 MPa
x (smallest) 300 mm
y (largest) 600 mm
bh (ratio of y & x) = y/x 2.0
dim. Of the critical shear perimeter measured // to the direction of M*v , a 300 mm (Also refer AS3600 Fig. 9.2.1 (B)
fcv 2.15 MPa AS3600 Cl. 9.2.3
Overall depth of Col. In the plane of B. Moment 0.30 m --> Eg. About y-y axis, My* -> d = eff. depth measure along or // to x axis
Min M* 37.50 kNm AS3600 Cl 10.1.2
M*v from RAPT 100 kNm with 100% column stiffness
M*v = larger of the 2 above = 100 kNm
V* 2500 kN
Cl.9.2.3 Ultimate shear strength where M*v = 0
Shear head 0 (1 = Yes, 0 = No)
Vuo (without shear head) 4115 kN AS3600 Eqnt 9.2.3(1)
Vuo (with shear head) 5755 kN AS3600 Eqnt 9.2.3(2)
Vuo 4115 kN
Cl.9.2.4 Ultimate shear strength where M*v is not 0
Ligs 1 (1 = Yes, 0 = No)
(a) No Closed ligs:
Vu = Vuo/[1+uM*v/(8V*adom)] 3631 kN AS3600 Eqnt 9.2.4(1)

Closed ligs provided:


(b) AS3600 Eqnt 9.2.4(2)_Torsion strip
Vu.min= 1.2Vuo/[1+uM*v/(2V*a2)] 2744 kN

Vu= Vu.min[(Asw/s)/(0.2y1/fsy.f)]^0.5................AS3600 Eqnt 9.2.4(4) 4125 kN < Vumax 5820 kN AS3600 Eqnt 9.2.4(5)
Asw 113 mm2
s 250 mm
y1 500 mm

Vu 4125 kN

Vu 4125
F 0.7
FVu 2887 kN Upper limit to Punching shear not exceeded
e along or // to x axis
15.5 %
Column location L1 grid J/4

u 4000 mm
D 600 mm
cover 50 mm
dom 550 mm
f'c 40 Mpa
P/A 1.3 MPa
x (smallest) 300 mm
y (largest) 600 mm
bh (ratio of y & x) = y/x 2.0
dim. Of the critical shear perimeter measured // to the direction of M*v , a 300 mm (Also refer AS3600 Fig. 9.2.1 (B)
fcv 2.15 MPa AS3600 Cl. 9.2.3
Overall depth of Col. In the plane of B. Moment 0.30 m --> Eg. About y-y axis, My* -> d = eff. depth measure along or // to x axis
Min M* 64.50 kNm AS3600 Cl 10.1.2
M*v from RAPT 0.00 kNm with 100% column stiffness
M*v = larger of the 2 above = 65 kNm
V* 4300 kN
Cl.9.2.3 Ultimate shear strength where M*v = 0
Shear head 0 (1 = Yes, 0 = No)
Vuo (without shear head) 5589 kN AS3600 Eqnt 9.2.3(1)
Vuo (with shear head) 7815 kN AS3600 Eqnt 9.2.3(2)
Vuo 5589 kN
Cl.9.2.4 Ultimate shear strength where M*v is not 0
Ligs 1 (1 = Yes, 0 = No)
(a) No Closed ligs:
Vu = Vuo/[1+uM*v/(8V*adom)] 5346 kN AS3600 Eqnt 9.2.4(1)

Closed ligs provided:


(b) AS3600 Eqnt 9.2.4(2)_Torsion strip
Vu.min= 1.2Vuo/[1+uM*v/(2V*a2)] 5030 kN

Vu= Vu.min[(Asw/s)/(0.2y1/fsy.f)]^0.5................AS3600 Eqnt 9.2.4(4) 7562 kN < Vumax 10670 kN AS3600 Eqnt 9.2.4(5)
Asw 113 mm2
s 250 mm
y1 500 mm

Vu 7562 kN

Vu 7562
F 0.7
FVu 5293 kN Upper limit to Punching shear not exceeded
e along or // to x axis
23.1 %